Dosing pumps
CDE-FCO - Manual pump with stroke speed adjustment
Pressure
bar
5
3
Flow
l/h
5
6,5
ACCESSORY KITS
n. 1
n. 1
n. 1
m. 2
m. 2
m. 2
n. 1
ALSO AVAILABLE
CDE-FCOS
Pump with manual stroke frequency
adjustment suitable for essence dosing.
Pump constructed to reduce sound output.
Fuse
Foot filter with valve
Injection valve
Delivery pipe
Suction pipe
Discharge pipe
Installation manual
ACCESSORY KITS are included with ALL chemical dosing pumps.
1
Dosing pumps
CDE-VCL - Manual pump with stroke speed adjustment and level control
Pressure
bar
5
10
Flow
l/h
1
4
3
2
10
17
Available with autodegassing
(self venting) pump heads
Pressure
bar
7
2
Flow
l/h
4
13
1
13,5
ALSO AVAILABLE
CDE-VCLG
Metering pump for flocculant with double
measurement scale (24h) with level probe.
CDE-VMS PH
Proportional pump driven by internal built-in
pH meter (0÷14pH) and level control,
supplied without pH probe.
From 0 to 300 gr/day
From 0 to 3000 gr/day
CDE-VMS RH
Proportional pump driven by internal
built-in ORP (ORP) meter (0÷1000mV)
and level control, supplied without ORP probe.
CDE-VMS EN
Metering pump for algicide with - weekly timer,
microprocessor digital controls, LCD dispaly and
level probe.
2
CDE-KCL - Manual pump with stroke length and stroke speed adjustment with level control
Pressure
bar
2
5
20
Flow
l/h
18
10
01
Available with autodegassing
(self venting) pump heads
Pressure
bar
2
5
20
Flow
l/h
13
7,5
0,5
ALSO AVAILABLE
CDE-KIS
Proportional pump driven by external digital
signal, with level control: to each external pulse
corresponds one pump injection.
CDE-KMS PH
Proportional pump driven by internal built-in
pH meter (0÷14pH) and level control,
supplied without pH probe.
CDE-KIC
Proportional pump driven by current signal
(0-4mA=0pulses; 20mA=max pulses) and level
control.
CDE-KMS RH
Proportional pump driven by internal
built-in ORP (ORP) meter (0÷1000mV)
and level control,supplied without ORP probe.
3
Dosing pumps
MULTI CHEMICAL MEASUREMENT AND CONTROL
CDE-WDPHCL
CDE-WDPHRH
pH & Chlorine
pH & Redox (ORP)
Swimming pool controller with 2 metering pumps.
Ranges: 0-14 pH and 0-10 mg/l Cl2. Chlorine
probe to specify at order. Controller settings by
wheel. LCD backlight display.
Pressure
bar
5
3
Flow
l/h
1
10
Ranges: 0-14 pH and 0-1000 mV.
Controller settings by wheel. LCD backlight
display.
Alarm output, max dosing time alarm, probe
check-up, pH priority dosing. Liquid ends in PVDF.
CDE-WDPHRHS
CDE-WDPHCLS
CDE-WDPHBRS
pH / Redox (ORP)
Swimming pool controller with one metering
pump for acid (pH) and one 230VAC output
driven by Redox (ORP) for salt generator or
dry feeder.
pH / Cl
Swimming pool controller with one metering
pump for acid (pH) and one 230VAC output
driven by Chlorine for salt generator or
dry feeder.
pH / Br
Swimming pool controller with one metering
pump for acid (pH) and one 230VAC output
driven by bromine for dry feeder (brominator).
Liquid ends in PVDF.
CDE-WPHRHC
pH Redox (ORP) with calculated
Chlorine (ppm) display
Swimming pool controller with 2 metering pumps.
Ranges: 0-14 pH and 0-1000 mV.
Adjustment using keypad. LCD backlight display.
Alarm output, max dosing time alarm, probe check-up,
pH priority dosing. Liquid ends in PVDF.
Probes specified at point of order.
4
Section pH / Redox
Pressure
bar
5
3
Flow
l/h
1
10
Solenoid Valve
VAC
230
Consumption
A
10
Pressure
bar
5
3
Flow
l/h
1
10
Multi parameter controllers
5-CHANNEL
CDE-MAX5
(pH / Total chlorine / Free chlorine /
Combined chlorine / Redox / °C /
Turbidity / Conductivity )
MAX5 is a multiple digital controller system. It reads and controls
up to 5 channels that can be programmed to control pH - ORP Chlorine - Turbidity - Temperature - Total Chlorine.
pH: from 0 to 14 pH
ORP (Redox): from 0 to 1000 mV
Total Chlorine: from 0 to 10 mg/l
Free Chlorine: from 0 to 10 mg/l
Combined Chlorine: from 0 to 10 mg/l
Turbidity: from 0 to 30 NTU
Temperature: from 0 to 100 °C
Conductivity: from 0 to 300 mS
2-CHANNEL
CDE-LDPHxx Series Digital Controllers
Digital controller with microprocessor and LCD backlight display. Using a revolutionary
wheel the controller can be easily programmed.
3 proportional setpoints and 2 proportional On/Off or timered (PWM) setpoints.
Stand-by input and max dosing time alarm. CHLORINE / BROMINE selector. Alarm for
probe failure. General alarm output.
CDE-LDPHRH pH (0÷14) - ORP (0÷1000mV) - °C (0÷99,9)
CDE-LDPHCL* pH (0÷14) - Chlorine (0÷10 mg/l Cl2)* - °C (0÷99,9)
CDE-LDPHO2 pH (0÷14) - O2 (0÷200 mg/l H2O2) - °C (0÷99,9)
CDE-LDPRC pH (0÷14) - Chlorine (0÷10 mg/l Cl2) - °C (0÷99,9)
5
and ORP only reading (0÷1000mV)
Board mounted equipment
FOR DOMESTIC & COMMERCIAL FEEDER APPLICATIONS
CDE-PA- WDPHEV
For pH and ORP control.
Salt chlorine generator or dry
feeder (brominator) output.
1
4
1. Controller WDPHRHS
2. NFIL Filter
3. Probe Redox ERHS
4. Probe pH EPHS
5. Probe Holder NPED4
3
Dimensions: 400x600 mm
2
5
CDE-PA- LDPHCLV
1
pH correction & free chlorine/
bromine proportional control of
a dry feeder (Chlorine/Bromine)
output
2
1. Controller
2. Dosing Pump
3. NFIL Filter
4. Probe pH EPHS
5. Proximity switch SEPR
6. Temperature probe ETEPT
7. Chlorine probe either:
> ECL6 (as pictured) or
> ECL3S/10
4
3
6
7
See page 13 for more information on chlorine probes.
Dimensions: 600x800 mm
5
6
Board mounted equipment
FOR DOMESTIC & LIGHT COMMERCIAL APPLICATIONS
CDE-PA- WDPHRH
For pH and Redox control.
1
1. Controller WDPHRH
2. NFIL Filter
3. Probe Redox ERHS
4. Probe pH EPHS
5. Probe Holder NPED4
Dimensions: 400x600 mm
4
3
2
5
CDE-PA- WDPHCL
For pH and Chlorine control
1
1. Controller WDPHCL
2. NFIL Filter
3. Proximity switch SEPR
4. Probe pH EPHS
5. Chlorine probe either:
> ECL6 (as pictured) or
> ECL3S/10
See page 13 for more information on chlorine probes.
Dimensions: 500x700 mm
4
5
2
3
7
Control and dosing
FOR COMMERCIAL APPLICATIONS
CDE-PA- LDPHCLVD
1
2
3
6
4
7
5
For pH and chlorine proportional control.
Medium size swimming pools.
1. Controller LDPHCL
2. Dosing Pump acid VMS MF 03 10 (10 l/h)
3. Dosing Pump chlorine VMS MF 02 17 (17 l/h)
4. NFIL Filter
5. Proximity sensor SEPR
6. Probe pH EPHS
7. Temperature probe ETEPT
8. Chlorine Probe - either:
> ECL6
> ECL3S/10
See page 13 for more information on chlorine probes.
Dimensions: 600x800 mm
8
8
Control and dosing
FOR HEAVY COMMERCIAL APPLICATIONS
CDE-PA-M5DB
2
1
4
3
7
8
9
10
5
11
12
6
13
For pH, ORP, Free chlorine, Total Chlorine, Combined chlorine,
Temperature, Flocculant and Algicide.
1. Multiparameters controller MAX5
(pH, Cl, Clt, T°)
2. Dosing Pump acid VMS MF 03 10
3. Dosing Pump chlorine VMS MF 02 17
4. Dosing Pump flocculant VCLG
5. Dosing Pump algicide VMS EN 07 06
6. NFIL Filter
7. Probe pH EPHS
8. Probe Redox ERHS
9. Temperature probe ETEPT
10. Probe free chlorine ECL3S/10
11. Probe chlorine ECL8/10
12. Proximity sensor SEPR
13. Probes holder PEF22
Dimensions: 1000x800 mm
9
Commercial systems
Control board
1. Controller(s) from our range
2. NFIL Filter
3. Probes and probe holder from our range
All panel mounted to suit your specification.
Pump board
Tank Set
Panel mounted board. Dosing pumps selected from wall
mount range. Board shown includes multifucntion valves
which offer:
1. Pressure Relief
2. Pressure Sustaining
3. Syphon/Bleed
Foot mounted dosing pump and electronic agitator
mounted on chemical dosing tank which can be bunded
to prevent chemical spillage.
Various dosing tank and bund sizes available.
10
Worldwide Control System
LAN - GPRS/GSM - Webserver with HOSTING service
“ERMES” - cOMMUNICATION SOFTWARE
Upto 30 controllers can be linked in a localised network using a RS485 protocol. Using ERMES software, you can monitor and manipulate each
controller remotely.
WAYS TO CONNECT
LOCAL control
All controllers, par the CDE-LD multichannel controllers can be fitted with a USB port for direct connection to the PC.
CDE-LD multichannel controllers can be connected using a RS485-USB converter.
For local control please select USB Basic. To allow data download directly from the controller to a USB memory stick, please choose USB advanced
ETHERNET control
Controller is fitted with an internal network point (Cat5e). Users can connect to the controller through a local network and the internet.
REMOTE control
Controller is fitted with an internal GPRS modem. Using a compatible mobile SIM card (sold separatley) it can be used to connect to the controller
remotely over the internet.
ERMES is capable of sending SMS alerts to upto 4 pre-programmed numbers or upto 4 email addresses for alarms. Users can also text the
controller to receive up to date readings from the controller
A summary of the available options is shown in the table below:
RS485 comm
USB* comm
BASIC configuration
•
•
ADVANCED USB configuration
•
•
ETHERNET configuration
•
•
GSM/GPRS configuration
•
•
Ethernet
module
modem
module
USB 2.0 module
Data Log
•
•
•
* Not available on LD Multichannel Series.
Points to consider before ordering:
• It is possible to retrofit communication modules to existing controllers.
• Modules can be installed internally or externally to suit
• Use of GSM/GPRS modem is dependant on mobile data signal. An external modem maybe required where signal strength is low.
• Ethernet connection requires direct, wired, connection to a local network. A system administrator will be required to configure firewall access
etc.
• It is possible to piggy back multiple controllers -- i.e. controllers wired, via RS485, into a controller with a GSM modem may also be connected
to over the internet
11
Worldwide Control System
LAN - GPRS/GSM - Webserver with HOSTING service
FEATURES
Standard configurations features are described in the table below:
RS485 net (1)
USB comm
service (2)
BASIC configuration
•
•
ADVANCED USB configuration
•
•
ETHERNET configuration
•
•
•
•
GSM/GPRS configuration
•
•
•
•
(1)
(2)
(3)
(4)
(5)
(6)
RS485 net:
USB comm service:
EMAIL alert service:
HTTP remote service:
SMS alert service:
USB data log:
EMAIL alert
service (3)
HTTP remote
service (4)
SMS alert
service (5)
USB data
log (6)
•
•
RS485 port for connecting instruments to network or to a PC using a converter
direct PC/instrument link using USB
email multi-level alert messages using standard pop protocol
instruments configuration using a standard browser
SMS multi-level alert messages using standard Short Message Service protocol
instrument data activity recorded on standard USB pen-drive
ERMES softward allows users to control and program controllers in many different ways:
Connection using a RS485 network and USB or RS485 cable.
This connection enables the user to control one or more instruments directly
connected to a PC.
Connection using a RS485 network and GSM modem or
RS485 cable.
PRINTER
This connection enables the user to control one or more instruments from
anywhere in the world via a standard Internet connection and a data SIM card.
USB
RS485
RJ45
GSM MODEM
DSL
ETHERNET Wi-Fi
ROUTER
Connection using a RS485 network and ETHERNET router.
This connection enables the user to control one or more instruments within a
LAN (Local Area Network).
Connection using a RS485 network and WIFI router.
This connection enables the user to control one or more instruments using
wireless technology as on notebooks.
USB
RS485 NETWORK
RJ45 NETWORK AND DSL ETHERNET/Wi-Fi ROUTER
GMS MODEM
iPAD
PRINTER
12
iPAD
Accessories
CDE-EPHS
CDE-ERHS
BUFFER SOLUTIONS
pH electrode for pressures up to 7bar/
70°C (3.5bar/80°C).
0.8m cable. Epoxy body.
Minimum 100μS.
ORP electrode for pressures up to
7bar/70°C (3.5bar/80°C).
0.8m cable. Epoxy body.
Minimum 100μS.
Buffer solutions for probe calibration.
CDE-ECL8
CDE-ECL6 - ECL12
Total chlorine amperometric cell (organic and inorganic),
from 0 to 2 mg/l ; from 0 to 20 mg/l, pH and temperature
compensated.
Free chlorine / bromine amperometric cell
(organic and inorganic), from 0 to 10 mg/l.
Flow switch and flow adjustment.
Electrode holder for pH, Redox and temperature.
With proximity switch mod. SEPR. 6x8 fittings.
CDE-ECL3S/10
CDE-ETEPT
Free chlorine amperometric cell (organic and inorganic),
from 0 to 10 mg/l, pH and temperature compensated.
Temperature probe (0°C÷100 °C, max 10bar).
13
Accessories
CDE-NFIL CA
CDE-NFIL
5” filter with carbon activated
filter cartridge. 6x8 fittings.
Filter with cartridge. Washable.
PET (60 μ). 6x8 fittings.
CDE-NPED4
Off-line electrode holder for EPH, ERH
electrodes. Temperature max 50° C,
max pressure 5bar with flow sensor with
N.O. contact. 6x8 fittings.
CDE-PEF22
CDE-PEF1
Free, total chlorine, pH, ORP and Temperature probes holder
with flow switch and flow adjustment. 6x8 fittings.
Best for MAX5 digital controller.
Off-line electrode holder for ECL1/2/3/8/9/10/11 and pH,
Redox and temperature, with flow switch and flow regulation.
With proximity switch mod. SEPR. 6X8 fittings.
CDE-PELC
PVDF in-line electrode holder
for pH / Redox electrodes
with 1/2” or 3/4” thread.
For saddle connection.
CDE-PEL
CDE-EVLA
PVDF in-line electrode holder
for pH / Redox electrodes
with 1/2” or 3/4” thread.
For “T” connection.
Solenoid valve for dry feeder. 1/2” fitting.
14
Accessories
CDE-MIXV/8
CDE-MIX/8
CDE-MIX/MAN
CDE-LASP/x
CDE-LASP1/x
High speed mixer
1400 RPM.
AISI shaft-PVC coated,
length available: 630
mm.
Marine impeller,
diameter 70 mm.
Low speed mixer
65/200/400 RPM.
AISI shaft-PVC coated,
different lengths
available
(630-730-980 mm).
3-blade impeller,
diameter 150 mm.
Manual mixer.
PVC shaft,
length available: 390 mm.
Impeller diameter 90 mm.
Suction lances
with level control,
for tanks up to
25 litres (suitable for
carboys).
Suction lances
with level control,
for tanks up to
1000 litres.
CDE-LINIR
1/2” injection lance for dosing sodium
hypochlorite in hard water. PVDF body.
Viton® or EPDM o-ring. Ball valve.
INJECTION
VALVE 1/2”
Injection valve (PVDF).
MF MULTIFUNCTIONS
VALVE
Multifunction valve (pressure, safety,
antisyphon and bleed) 1/2” connections
for different hose diameters. Pressure
range adjustable from 1 to 5 bar for
pressure valve operating mode, from
1 to 18 bar for safety valve operating
mode. Discharge connection
3/8” 4x6. Viton® or EPDM o-ring.
PVDF body.
CHEMICAL TANKS &
SAFETY BUNDS
LEVEL PROBE
Polyethylene, anti-UV for chemicals. Complete chemical
tanks with safety bunds.
Level probe with foot filter and BNC
connector (full natural PVDF).
15
Notes
16
17
Certikin Ltd • Witan Park • Avenue Two • Station
Lane Industrial Estate • Witney • Oxon • OX28
4FJ • Reg. in England No. 3047290
E-mail: [email protected]
Certikin France. - ZI de Torremilla - 219 Rue Henry
POTEZ - 66000 PERPIGNAN Tél : 04 68 52 64 30
Fax: 04 68 52 64 30 - [email protected] sentex-france.com
Certikin Pool Ibérica S.L.U. P.I. Mas Puigvert-Oest
19-20 Parc.3 - 08389 Palafolls (BARCELONA) Tel:
902 02 03 42 Fax: 93 764 53 97
Certikin Italia SpA - Via Gavardina 96/98/100
25010 Ponte S.Marco (BS) Italia - Tel. +39
030 9980088 Fax +39 030 9637619 - P.I.
00813790987 - Reg. Imp. di Brescia 00813790987
- Capitale Sociale € 300.000,00 int. vers.
Certikin India
7a Dyavasandra Industrial Estate
3rd Cross
Singayanapalya
Bangalore India 560048
T + 91 80 4094 3024
F + 91 80 4094 3025
Certikin Middle East
Jebel Ali Free zone
Dubai
T+ 971 4 8861404
F + 971 4 8861004
18
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement