SX15 iR2 and SX20 iR2 Series Mode Pro™
SX15 iR2 and SX20 iR2 S e r i e s
Mode Pro™
Surge Suppressor and Power Conditioner
U.S. Patents 4,870,534 and 4,870,528
TOP VIEW
FRONT VIEW
The SX15 iR2 and SX20 iR2 are specifically designed to upgrade and
improve surge protection for audio, video and computer equipment.
Compact standalone units with optional mounting brackets, the surge
suppressors easily mount in an equipment rack. Both models have two
three-prong receptacles on the front panel. The SX15 iR2 provides 15 amp
protection; the SX20 iR2 is rated for 20 amps.
SurgeX patented Series Mode Pro technology is superior to conventional MOV circuitry. It provides proven, reliable protection; stopping surges
of up to 6,000 volts, without producing ground contamination.
These components meet the most stringent government purchase
specifications for powerline surge suppressors. Their A-1-1 rating assures
you of dependable protection from destructive spikes, surges and inductive
transients.
Professional AC Power Products
SURGE PROBLEMS ARE HISTORY!
6131-B Kellers Church Road
Pipersville, PA 18947
PH 215-766-1240
FAX 215-766-9202
www.surgex.com
SX15 iR2 and SX20 iR2 S e r i e s
Mode Pro™
Surge Suppressor and Power Conditioner
SPECIFICATIONS
FEATURES
Load Rating: SX15 iR2 - 15 amps @ 120 volts; SX20 iR2 - 20 amps @
120 volts.
■
Made in U.S.A.
■
Magnetic shielding steel enclosure
■
6’ grounded 3-wire line cord; #14 cord for
UL 1449-2 Adjunct Classification Test Results: 1000 surges, 6000
volts, 3000 amps, C1 pulse, measured suppressed voltage 290 volts, no
failures.
SX15 iR2; #12 for SX20 iR2
Two three-prong AC receptacles on top
1996 U.S. Government Guidelines, Grade A, Class 1, Mode 1: SX15 iR2
and SX20 iR2 meet guidelines.
■
Limiters (3 circuits): Series surge reactor current limiter. Cascaded, autotracking dual polarity voltage limiter. Dual pulse inverters.
■
Self-test circuit with visual indicator
■
Dimensions:
panel
Clamping Voltage Onset: 172 volts nominal (2 volts above peak line
voltage, auto-tracking).
SX15 iR2: 3.2” H x 7.8” W x 3.75” D
Filter (bi-directional, wave tracking): With 50 ohm load: 3 dB @ 3 kHz;
38 dB @ 100 kHz; 50 dB @ 300 kHz.
SX20 iR2: 3.4” H x 7.8” W x 3.75” D
Let-Through Slew Rate: 5000 volt/µs disturbance reduced to 28 volt/µs
within power wave envelope; less than 10 volt/µs outside power wave
envelope.
Snubber: Instant-reacting snubber for fast-rising surges generated within
the building.
(8.1 x 19.8 x 9.5 cm)
(8.6 x 19.8 x 9.5 cm)
■
Weight:
SX15 iR2: 5.0 lbs (2.25 kg)
SX20 iR2: 5.5 lbs. (2.48 kg)
Maximum Applied Surge Pulse Joule Rating: Unlimited, due to current
limiting (8 x 20 µs).
Maximum Surge Pulse Voltage: 6000 volts (1.2 x 50 µs pulse), industry
standard rating.
Maximum Applied Surge Pulse Current: 100,000 amperes (8 x 20 µs).
Endurance, IEEE C62.41-1991 Category B3 (C1) Pulses: 1 kv>500,000;
3 kv>10,000; 6 kv>1000 (NRTL-UL certified).
ARCHITECTURAL AND ENGINEERING SPECIFICATIONS
The surge suppressor shall be a compact standalone unit in a durable
steel enclosure. It shall operate from 120 volts AC and have a 6-foot,
grounded, 3-wire #14 (#12 for SX20 iR2) line cord. There shall be two standard three-prong AC receptacles on the top panel and a self-test circuit
with visual indicator. Overall dimensions shall be 3.2” H (3.4” for SX20
iR2) x 7.8” W x 3.75” D. Weight shall be 5.0 pounds (5.5 pounds for
SX20 iR2).
The surge suppressor shall have a load rating of 15 amps @ 120 volts (20
amps for SX20 iR2). It shall be UL 1449-2 Listed and meet 1996 U.S.
Government Grade A, Class 1, Mode 1 Guidelines for powerline surge
suppressors. There shall be three limiter circuits: a series surge reactor
current limiter, a cascaded auto-tracking dual-polarity voltage limiter, and
dual pulse inverters. The onset clamping voltage shall be 172 volts, nominal,
and the unit shall have an instant-reacting snubber to protect against fastrising surges generated within the installation location. The surge suppressor shall have an unlimited Applied Surge Current rating (8 x 20 µs) and
shall withstand at least 1000 occurrences of Surge Pulse Voltages up to
6000 volts.
WHEN DOWNTIME IS NOT AN OPTION!
Specifications subject to change without notice.
Professional AC Power Products
6131-B Kellers Church Road
Pipersville, PA 18947
PH 215-766-1240
FAX 215-766-9202
www.surgex.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising