abcdefg - Land Instruments
STANDARD
AND
FIBROPTIC
THERMOMETERS
abc abcdefg
INFRARED APPLICATIONS
Non contact temperature measuring systems are designed for
continuous quality and process monitoring and control in a wide
range of industries including:- Iron & Steel, Glass, Plastics,
Rubber, Minerals, Paper... and many more.
With measurement capabilities from 0 to 2600°C, infrared
thermometers measure both the product being processed and
the plant and machinery used in the production. Here are just a
few of the processes where SYSTEM 4 can solve your
measurement problems:-
Metal Production
Smelting, refining, pouring, continuous casting,
slabbing, reheating, rolling, drawing, coiling,
extruding, coating, annealing, stamping, pressing,
forging, sintering, galvanising, heat treatment...
Glass Production
Melting, refining, firing, gob formation, furnaces,
floating, moulding, toughening, laminating, fibre
drawing, vapour deposition, preforming...
Mineral Processing
Firing, mixing, drying, storing, conveying, laying...
Paper
Rolling, drying, calendering, coating, printing,
photographic, curing..
Plastics & Rubber
Thick & thin film plastics, blown film, thermoforming,
calendering, orientation, extruding, mixing, shrinking,
laminating, moulding...
Chemical
Catalyst beds, powder drying, mixing, furnaces,
thermal reactors...
Food & Pharmaceuticals
Freezing, moulding, extruding, sterilising, tablet drying,
labelling, sealing...
Electronics
Wave soldering, glass coating, circuit board testing,
doping...
There is a choice of thermometer type to match your temperature
requirements and process.
Single wavelength thermometers are intended for general purpose
use as well as solving problems in specific applications.
Ratio thermometers are used in difficult environments containing
steam, smoke, or dust, or where the target does not completely
fill the field of view.
Fibroptic thermometers are used to measure the temperature of
materials where the target is difficult to access.
The use of fibre optics is most effective in high temperature, high
magnetic fields etc. which would prevent location of other sensors.
SYSTEM 4 THERMOMETERS
SYSTEM 4 comprises an advanced range
of high precision radiation thermometers,
LANDMARK® processors and a range of
mounting accessories which combine to
form a complete temperature
measurement system.
SYSTEM 4 thermometers offer exceptional
flexibility with a choice of single
wavelength, ratio, fibroptic and fibroptic
ratio models.
Typical System
Thermometer type, temperature range, spectral
response and optical characteristics are chosen to suit
any application from 0 to 2600°C.
• Focusable optics - standard and short focus versions
with through-the-lens sighting providing clear and
guaranteed definition of target
• Optional close-up lenses - giving measurement of
targets as small as 0.45mm
• Accurate, reliable, drift-free measurement
• Rugged design with a range of mounting options
• Flexible fibre optics light guide versions - with optional
laser targeting system to define target spot
• High level linear output
RADIATION THERMOMETERS
Standard Bodied Thermometer
Fibroptic Thermometer
Proven, reliable electronics and a high quality optical system
combine to give a thermometer which delivers accurate,
dependable temperature measurement. A rugged die-cast
aluminium body, with a high quality electrical connector, ensures
reliable performance.
Standard bodied thermometers all feature through-the-lens
sighting with a 6° field of view. Adjustable focus with a circular
graticule gives precise alignment on to the smallest of targets. Two
optical variants are available: Standard focus - adjustable
between 500mm and infinity, and Short-focus - viewing from
350mm to 1m. Close-up lenses are also available which can
measure targets as small as 0.45mm from as close as 90mm.
FIBROPTIC THERMOMETERS
The use of flexible fibre optics light guides allows the detector and
electronics enclosure to be located in a less hostile environment,
and enables access to difficult targets.
The fibroptic thermometers are available with an optional integral
laser targeting system which defines the target spot for accurate
alignment.
The use of fibre optics permits viewing of normally inaccessible
targets, where there are high magnetic fields or in high ambient
temperatures up to 200°C without cooling of the optic head. There
is a choice of three optic heads and three light guide lengths.
Thermometer Description
Model Nº
Wavelength
(µm)
Range
Minimum
Target
Dia* (mm)
M1 450/1000C
M1 600/1600C
M1 800/2600C
1.0
1.0
1.0
450 to 1000°C
600 to 1600°C
800 to 2600°C
3.0
0.9
0.45
M2 300/1100C
1.6
300 to 1100°C
0.9
M4 50/250C
M4 150/550C
2.4
2.4
50 to 250°C
150 to 550°C
3.2
1.0
M1 Thermometers
M1 thermometers are intended for general purpose use in high
temperature applications. They utilize a silicon cell detector and
operate at short wavelengths around 1.0µm where emissivity errors
are minimized. They have a fast response time of 5ms.
M2 Thermometers
M2 thermometers use the latest generation of germanium detectors
and operate at a wavelength of 1.6µm. They extend the measurement
range of short wavelength thermometers down to 300°C and have
a fast response time of 5ms.
M4 Thermometers
M4 short wavelength thermometers are used on low temperature, low
or uncertain emissivity surfaces such as bright or unoxidized metals.
They use lead sulphide detectors in a unique null balance mode to
guarantee stability. They have a response time of 100ms.
M5 Thermometers
M5 thermometers are specifically designed for glass surface
temperature measurement.
Fast speed of response, coupled with small target size and accurate
sighting facility make it ideal for all flat glass, glass toughening and
optical fibre preform applications.
M5 400/1300C
M5 1000/2500C
4.8 to 5.2
4.8 to 5.2
400 to 1300°C
1000 to 2500°C
1.0
1.0
M6 0/300C
M6 100/700C
3.0 to 5.0
3.0 to 5.0
0 to 300°C
100 to 700°C
3.2
1.0
M7 25/375C
3.43
25 to 375°C
3.2
M8 0/1000C
8 to 14
0 to 1000°C
5.0
M6 Thermometers
M6 thermometers are designed specifically for lower temperature
applications. Unique short wavelength operation minimizes errors
due to low or variable emissivity.
M7 Thermometers
M7 thermometers operate at waveband selected especially for
measurement on plastic films as thin as a few microns.
M8 Thermometers
M8 thermometers measure from 0 to 1000°C and are ideal for
applications such as food, textiles, paper and plastics. They operate
at a waveband which avoids the effects of atmospheric absorption.
R1 Ratio Thermometers
R1 ratio thermometers use dual silicon cell detectors operating at
0.85 to 1.1µm. They are intended for difficult, high temperature
applications where the field of view is not fully filled or where the sight
path is obscured. They can accurately measure temperature of
targets with up to 95% obscuration.
R1 600/1600C
R1 1000/2600C
0.85 to 1.1
0.85 to 1.1
600 to 1600°C
1000 to 2600°C
1.8
0.45
* When fitted with Close-up lens
Fibroptic M1 Thermometers
Fibroptic M1 thermometers combine the flexibility of fibre optics with
short wavelength operation. They can be used in high temperature
applications such as metals, glass, coke ovens and induction heating.
M1 600/1600CYL
M1 800/2600CYL
1.0
1.0
600 to 1600°C
800 to 2600°C
4.0
1.3
M2 300/1100CYL
1.6
300 to 1100°C
4.0
M3 50/250CQ
2.1
50 to 250°C
5.0
600 to 1600°C
1000 to 2600°C
4.0
1.3
Fibroptic M2 Thermometers
Fibroptic M2 thermometers can be used in applications such as
glass mould temperatures where access to the target is restricted,
or limited to a few milliseconds.
Fibroptic M3 Thermometers
Fibroptic M3 thermometers are designed for low temperature
applications, with low or uncertain emissivity, such as secondary
metals.
Fibroptic R1 Ratio Thermometers
Fibroptic R1 ratio thermometers provide accurate high temperature
measurement of small intermittent targets, such as rod and wire, and
tube welding. Other applications include kilns and vacuum furnaces.
R1 600/1600CYL
R1 1000/2600CYL
0.85 to 1.1
0.85 to 1.1
Y denotes Laser Targeting Version
THERMOMETER SPECIFICATIONS
STANDARD THERMOMETERS
Model
Field
of View
Ambient
Temperature
Response
Time (1)
Interchangeability
Repeatability
M1 450/1000C
450 to 1000°C
1µm
30:1
0 to 70°C
5ms
<1K
1K
0.4%K
<0.2K/K
M1 600/1600C
600 to 1600°C
1µm
100:1
0 to 70°C
5ms
<1K
<1K
0.4%K
<0.2K/K
M1 800/2600C
800 to 2600°C
1µm
200:1
0 to 70°C
5ms
<1K
2K
0.7%K
<0.3K/K
M2 300/1100C
300 to 1100°C
1.6µm
100:1
0 to 50°C
5ms
<1K
<1K
0.25% + 1K
<0.2K/K
50 to 250°C
2.4µm
30:1
5 to 45°C
100ms
<1K
1K
3K
<0.1K/K
M4 150/550C
150 to 550°C
2.4µm
100:1
5 to 45°C
100ms
<1K
1K
4K
<0.1K/K
M5 400/1300C
400 to 1300°C
4.8 to 5.2µm
100:1
0 to 70°C
100ms
<2K
<1K
0.6%K(4)
<0.02%K/K
M5 1000/2500C
1000 to 2500°C
4.8 to 5.2µm
100:1
0 to 70°C
100ms
<2.5K
1K
0.5%K
<0.02%K/K
0 to 300°C
3 to 5µm
30:1
5 to 45°C
100ms
<1K
<1K
0.3% + 2.5K
<0.15K/K
100 to 700°C
3 to 5µm
100:1
5 to 45°C
100ms
<1K
1K
0.3% + 2K
<0.2K/K
25 to 375°C
3.43µm
30:1
5 to 45°C
100ms
<1K
1.5K
3K
<0.1K/K
0 to 1000°C
8 to 14µm
100:1
0 to 70°C
100ms
2K
<1K
1%K + 1K
<0.3K/K
R1 600/1600C
600 to 1600°C
0.85 to 1.1µm
50:1
0 to 50°C
15ms
0.25%K
1K
0.65% K
<0.05%K/K
R1 1000/2600C
1000 to 2600°C
0.85 to 1.1µm
200:1
0 to 50°C
15ms
0.45%K
2K
1.1% K
<0.1%K/K
M1 600/1600CYL
600 to 1600°C
1µm
25:1
0 to 70°C
5ms
<1K
<1K
0.4%K
<0.2K/K
M1 800/2600CYL
800 to 2600°C
1µm
75:1
0 to 70°C
5ms
<1K
2K
0.7%K
<0.3K/K
M2 300/1100CYL
300 to 1100°C
1.6µm
25:1
0 to 50°C
5ms
<1K
<1K
0.25% + 1K
<0.2K/K
50 to 250°C
2.1µm
20:1
0 to 50°C
<100ms
1K
1K
3K
<0.1K/K
600 to 1600°C
0.85 to 1.1µm
25:1
0 to 50°C
15ms
0.25%K
1K
0.65% K
<0.05%K/K
R1 1000/2600CYL 1000 to 2600°C
0.85 to 1.1µm
75:1
0 to 50°C
15ms
0.45%K
2K
1.1% K
<0.1%K/K
(3)
M6 0/300C
M6 100/700C
M7 25/375C
(3)
FIBROPTIC THERMOMETERS
M8 0/1000C
(1)
Stability
Wavelength
M4 50/250C
M3 50/250CQ
(3)
R1 600/1600CYL
Time quoted to 95% of step change
(2)
Accuracy quoted to ITS90
(3)
Above 75°C
STANDARD OPTICAL SPECIFICATIONS
Focus range
Sighting
0.5m to infinity (V version)
0.35 to 1.0m
(S version)
6° graticule-defined field of view
1.8x magnification
30mm eye relief (with or without
spectacles/ safety glasses)
98% of energy detected is guaranteed to
be within area defined by graticule
FIBROPTIC OPTICAL SPECIFICATIONS
Focus range
None (A50 or D50)
Blue (A25), Purple (D25)
Red (A10), Green (D10)
Lightguide length
Determined by Spacer fitted
500mm
250mm
100mm
1.0m, 2.0m and 3.5m
(4)
Optimised for glass toughening = 3K at 630°C
Accuracy
(2)
Range
Y Denotes laser targeting system available
ENVIRONMENTAL SPECIFICATIONS
Vibration
Humidity
CE
Sealing
Fibroptic: Optic Head
Lightguide
3g - 60 to 300Hz, 0.5mm - 10 to 60Hz
0 to 99% non condensing
EN 50-082-2 (immunity)
EN 50-081-1 (emission)
To IP54 requirements
200°C Maximum ambient temperature
200°C Maximum ambient temperature
OPTIONAL EXTRAS
Standard Body
Close-up lenses
Fibroptic
Laser targeting
Note: 'D' focal variants relate to M3 only
Field of View (FOV)
Target Diameter (d)
SIGHTING
View through
the viewfinder
Target Distance (D)
Datum
Fibre Optics
L10 = 1m long
L20 = 2m long
L35 = 3.5m long
Target size calculation
To calculate the target size at the
focused distance, use the simple equation;
d=
D
FOV
Laser Targeting
(optional)
Target diameter
(see below)
Y = Laser Targeting System
FIBROPTIC THERMOMETER TARGET SIZES
Target diameter
A10 (Red Spacer)
100mm focus
4.0mm
A25 (Blue Spacer)
250mm focus
10.0mm
A50 (No Spacer)
500mm Focus
23.0mm
250mm
500mm
M1, M2, R1 Fibroptic Thermometers
25:1 Field of view
Target distance
100mm
M1, M2, R1 Fibroptic Thermometers
75:1 Field of view
Target diameter
1.3mm
Target diameter
D10 (Green Spacer)
100mm focus
5.0mm
3.3mm
6.7mm
D25 (Purple Spacer)
250mm focus
12.5mm
D50 (No Spacer)
500mm Focus
25.0mm
250mm
500mm
M3 Fibroptic Thermometer
20:1 Field of view
Target distance
100mm
THERMOMETER MOUNTINGS AND ACCESSORIES
A complete range of thermometer protection and mounting
accessories is available, which provides full mechanical and
thermal protection for the thermometer and electrical
connections, and ensures undisrupted service with minimal
maintenance, in even the most severe operating conditions.
For more information, refer to the Mountings and Accessories
Brochure - ref S4M100
DIMENSIONS
75
114
All dimensions in millimetres
Mounting holes
1/4in BSW
46
25
25
80
157
Laser Targeting Switch
M22 x1.5P
thread
114
Fibre Optics
115 approx.
Mounting holes
1/4in BSW
25
46
80
25
157
ORDERING INFORMATION
SYSTEM 4 thermometers have a unique
part number to suit the particular
combination of features which make up the
model.
The model number, consisting of the
various options available, describes the
exact SYSTEM 4 thermometer type
required.
This model number can be used for
selection and ordering purposes.
For example: M1 600/1600 C - V
describes a single wavelength
thermometer, operating at 1.0µm, with a
measurement span of 600 to 1600°,
celsius version, with standard variable
focus optics.
M
1
6 0 0
1 6 0 0
C
Y
V
1 0
A 1 0
Optics
V Variable Focus (Standard)
S Short Variable Focus
L Fibroptic (Standard)
Q Fibroptic (Quartz Anhydrous)
Min
Temp
Max
Temp
Units
Laser
C Celsius
F Fahrenheit
Fibroptic laser
targeting system
Detector and Wavelength
1 Silicon (1µm)
2 Germanium (1.6µm)
3 Indium Gallium Arsenide Cell (2.1µm)
4 Lead sulphide (2.3µm)
5 Thermopile (4.8 to 5.2µm)
6 Lead Selenide cell (3 to 5µm)
7 Lead Selenide cell (3.43µm)
8 Thermopile (8 to 14µm)
Fibre Optics Lightguide
L
Q
L10
L20
L35
Q10
Q20
Q35
M Single Wavelength
R Ratio
1m long
2m long
3.5m long
1m long
2m long
3.5m long
Optic A10
Head
A
A
Thermometer Series
1 0
D
D
A25
A10
A25
A50
A50
D10
D25
D10
D25
D50
D50
100mm
250mm
500mm
100mm
250mm
500mm
Focus
Focus
Focus
Focus
Focus
Focus
A 1 0
For more than fifty years LAND have supplied temperature measuring and process imaging
systems to many different industries all over the world. Now the world leader in non contact
thermometry, our expert advice and support is never far away.
WORLD LEADERS
WORLDWIDE SUPPORT
LAND is the world leader in the
manufacture of non contact
temperature measurement
systems, thermal imagers and
linescanners.
WORLDWIDE
SUPPORT
In addition to the companies
established in Europe, USA,
Mexico and Japan, LAND is
represented by distributors in
most of the major industrial
countries throughout the world.
Our customers benefit, on a
global basis, from practical and
expert advice from fully trained
technicians who are aware of
specific requirements for their
country and industry.
Expert advice and support is never far away
CALIBRATION
APPLICATIONS
LAND have solved many different temperature measurement problems in a wide variety of industries
from food to atomic energy, some of which are list below:
•
•
•
•
•
Iron & Steel
Petrochemical
Heat Treatment
Minerals
Glass
•
•
•
•
•
Maintenance
Power & Utilities
Aerospace
Electronics
Pharmaceuticals
•
•
•
•
•
Plastics
Paper
Rubber
Textiles
Non-ferrous Metals
For further information or free advice on specific temperature measurement problems within these or
any other industry, contact your nearest Land office.
PRODUCT ASSURANCE
When you specify LAND products you are assured of receiving a completely pretested, calibrated
working product. Each instrument is carefully checked to ensure complete compliance with specification
and is fully guaranteed. LAND was the first manufacturer of infrared instruments to successfully obtain
ISO 9001 Quality Management System Approval for both design and manufacture of non contact
infrared temperature measuring equipment.
A
LAND operate an extensive
calibration
service.
All
calibrations made are traceable
to
National
Standards.
Calibration certificates are
available from our UKAS
accredited calibration laboratory
0034.
In the USA a traceable
calibration certificate can be
issued complying with the
National Institute of Standards
and Technology (NIST).
A consultancy service is also
available for those companies
who wish to establish their own
in-house calibration facility.
These products comply with current European directives relating to electromagnetic compatibility
and safety (EMC directive 89/336/EEC; Low voltage directive 73/23/EEC).
The Quality Management System of Land Instruments International Ltd. Is approved to BS EN ISO9001:2000
for the design and manufacture, stockholding, in-house repair and site servicing of non contact temperature
measuring instrumentation. Associated software designed and developed in accordance with TickIT.
Calibration certificates are available from our UKAS accredited Calibration Laboratory No. 0034. The Land
calibration laboratory complies with the requirements of the international standard BS EN ISO/IEC 17025.
abc abcdefg
Land Instruments International • Dronfield S18 1DJ • England • Tel: (01246) 417691 • Fax: (01246) 410585
Email: infrared.sales@landinst.com • Internet: www.landinst.com
Land Instruments International • 10 Friends Lane • Newtown, PA 18940-1804 • U.S.A. • Tel: (215) 504-8000
Fax: (215) 504-0879 • Email: irsales@landinstruments.net • Internet: www.landinstruments.net
Printed in England
France
Land Instruments Sarl
Tel: (1) 34 62 05 45 • Fax: (1) 30 56 51 12
Email: commercial@landinst.fr
Germany
Land Instruments GmbH
Tel: 02171/7673-0 • Fax: 02171/7673-9
Email: infrarot@landinst.de
Italy
Land Instruments Srl
Tel: 02/99040423 • Fax: 02/99040418
Email: infrared@landinst.it
Japan
Land KK
Tel: 06 6330 5153 • Fax: 06 6330 5338
Email: ikeland@silver.ocn.ne.jp
Spain
Land Instruments International
Tel: 91 630 0791 • Fax: 91 630 2918
Email: land-infrared@landinst.es
Mexico
Land Instruments International
Tel: 52 55 9171 1466 • Fax: 52 55 9171 1477
Email: ventas@landinstruments.net
Continuous product development may make it necessary to change these details without notice.
S4T101E/0303
PROCESSORS
AND
SYSTEM
abc abcdefg
OVERVIEW
For over 50 years, Land have been the
world leaders in delivering solutions to
temperature measurement problems.
The new family of products, combining
unrivalled expertise and design knowhow with the latest technology is...
SYSTEM 4 gives you a choice of
products which covers all applications,
environments and budgets, ensuring
premium performance at competitive
prices. Compatibility and
interchangeability of each product
ensures maximum flexibility, both at
time of purchase and subsequently for
easy maintenance.
Non contact temperature measuring systems are designed for
continuous quality and process monitoring and control in a wide
range of industries. They can be used in a variety of applications
such as metal production, processing, foundry and forging, glass,
electronics, mineral processing and petrochemical where
accurate measurement of temperature is vital.
No other method of temperature measurement offers the
benefits of non contact infrared radiation thermometry.
• Infrared radiation thermometer systems measure continuously
the temperature of hot, moving or normally inaccessible
materials accurately and safely at a distance.
• Sensing heads do not require contact with the target object,
and therefore cannot interfere with, damage or contaminate
the product they are measuring.
• Thermometers do not remove heat or disturb the process
being monitored and offer the only solution when the product
is small, fragile or in a vacuum or controlled atmosphere.
SYSTEM 4 gives you a wide choice of compatible items to ensure
the system you buy is optimized to meet the needs of your
application, budget and environment.
LANDMARK® processors are designed to produce the process
control variables you need from ANY of the SYSTEM 4 sensors.
With this total compatibility, you are free to choose a processor to
give the features and performance you need and select the
sensor type best suited to the application. All SYSTEM 4
processors and sensors are calibrated individually to guarantee
interchangeability and hence easy maintenance for many years.
SYSTEM 4 offers an extensive, and expanding, range of
Standard and Fibroptic thermometers, designed to cover all
industrial non contact temperature measurement applications.
PROCESSORS
The heart of any temperature measurement system is the signal
processor. A LANDMARK® signal processor puts the controls of
your system where you need them - panel mounted or DIN rail
mounted, the choice is yours. SYSTEM 4 uses high speed
inputs, real time signal processing and flexible outputs to
convert the output of each sensor into real process variables.
LANDMARK® GRAPHIC is the state-of-the-art, panel mounted
signal processor, designed to control and process data from any
SYSTEM 4 Thermometer. The Multi-channel processor accepts,
processes and displays inputs from any combination of up to four
separate thermometers simultaneously - it is not multiplexed.
Multiple outputs are provided which can be integrated directly
into any process monitoring, recording or control system.
LANDMARK® GRAPHIC processors offer a variety of features
and advanced time functions which present temperature data in a
choice of displays and outputs to suit the particular application.
LANDMARK® GRAPHIC processors are rugged, and extremely
versatile, utilizing the latest technology available, giving you more
choice and more precision in the measurement of temperature.
For applications which do not require this high level of processor
power, a simple alternative is available - LANDMARK® CLASSIC.
LANDMARK® CLASSIC can be used with any SYSTEM 4
Thermometer. It displays the measured temperature and optional
plug-in cards give you a choice of either a peak picker or
averager time function, plus up to two alarm modules.
LANDMARK® TECHNIC is a high precision, DIN-rail mounted
intelligent digital processor. Its features include adjustable
emissivity/non-greyness, peak picker, averager, track and hold,
alarm and 4 to 20mA outputs, and RS232C serial
communications for set up via a PC.
LANDMARK® BASIC is a simple DIN-rail mounted signal
processing unit, providing simple signal conditioning with
economy and versatility.
THERMOMETERS
SYSTEM 4 includes an extensive range of mountings and
accessories which provides protection and accurate alignment for
both Standard and Fibroptic thermometers. All mountings permit
quick and tool-free installation and removal of
thermometers, keeping downtime to the absolute minimum.
Infrared radiation thermometers do not require contact with the
target object, so they cannot interfere with, damage, or
contaminate the product they are measuring. They do not
remove heat or disturb the process being monitored and offer the
only solution when the product is moving, small, fragile, or in a
vacuum or controlled atmosphere.
SYSTEM 4 Thermometers all feature temperature spans and
operating wavebands selected to ensure optimum accuracy of
measurement for each application.
Any SYSTEM 4 thermometer, selected from the extensive range
available, can be used with any SYSTEM 4 LANDMARK®
processor, allowing you to build a temperature measurement
system designed specifically to your application requirements.
Standard thermometers feature precision through-the-lens
focusable optics which guarantee exact viewing and accurate
measurement of the smallest of target areas.
Single wavelength thermometers are intended for both general
purpose use as well as solving problems in specific applications.
Fibroptic thermometers are used to measure the temperature of
materials where the target is difficult to access, and where high
temperature or high magnetic fields prevent the use of other
types of sensor.
Ratio thermometers are used in difficult environments containing
steam, smoke, or dust, or where the target is small or does not
completely fill the field of view.
For more details, refer to the 'System 4 Standard and Fibroptic Thermometers' Brochure
LANDMARK® GRAPHIC is the premier
non contact temperature
measurement system offering an
extensive range of standard features
and user benefits.
•
•
•
•
•
Highest system accuracy
High speed, high precision, real time signal processing
Unique Multi-channel and Math Function options
Modular, expandable system design
Simple, user-friendly interface with large numeric
and graphic displays
• Selectable time functions and alarm settings
• 0 to 20mA, 4 to 20mA and 1mV/° outputs to suit all
industry control systems
• Optional Serial Communications
Channel D
Channel C
Four output channels
Channel B
Output A
Output B
Output C
Output D
Channel A
Function 1
LANDMARK® GRAPHIC is a high precision, intelligent multiple
microprocessor-based thermometer signal processor, designed
to give the ultimate in process monitoring and control.
LANDMARK® GRAPHIC processors are multi-channel capable
and can be configured to work with up to four different SYSTEM
4 thermometers simultaneously.
A Math Function option is available which applies userconfigured math functions to the temperature measurement
signals from the thermometers in the system.
The processor supplies power to each thermometer and the
control signals required for either emissivity or non-greyness
compensation. A large LCD display shows temperature and
parameter variables, and system outputs.
Alarm Output
4 to 20mA Output
Display
A complete range of thermometer signal conditioning functions
is provided including: peak picker, averager, track and hold, and
alarm outputs.
Typical Difference display
Landmark Graphic Processor fitted with Math function option
MULTI-CHANNEL CAPABILITY
The Multi-channel version of the LANDMARK® GRAPHIC
processor provides up to four fully featured and independent
temperature measurement systems in one package.
Any SYSTEM 4 Thermometer can be connected to any input
channel of the processor. Each channel is fully independent of
the other, the inputs are not multiplexed. Additional channels
may be added as required without affecting existing settings.
Function 2
Alarm Output
4 to 20mA
Output
Display
The processor can control all types of SYSTEM 4 thermometer
simultaneously (i.e. M1, R1, M6 etc.). The thermometers can
have differing temperature ranges and even units (°C or °F).
Each channel has identical features to the single channel version;
two analog outputs; a fully scaleable 0 to 20 or 4 to 20mA output,
and a 1mV/° output. Two alarm outputs, both either High or Low
activated, each with changeover relay, are provided on every
channel card.
MATH FUNCTIONS
The unique multi-channel capability of the LANDMARK®
GRAPHIC makes possible the, also unique, Math Function
option. The processor accepts and compares up to four
thermometer signals. The results are then output to the process
control instruments in the form most suited to their requirements.
Two independent math functions are provided, each can
calculate, display and output either the Maximum, Minimum,
Mean, Difference or Range of temperatures measured by the
selected thermometers in your system.
The Expanded Span function allows you to extend the span of
your temperature measurement system from the minimum
temperature of the thermometer with the lowest temperature
range, to the maximum temperature of the thermometer with the
highest temperature range.
Any SYSTEM 4 Thermometer can be used in conjunction with the
Math Functions. Up to four SYSTEM 4 Thermometers can be
connected to the processor and two Maths Functions can be
configured. There are many different options for each Math
Function, the same option can be selected for both functions if
required.
Typical Expanded Span display
Each Math Function is fully independent from the other, and both
are independent from the four individual thermometer
temperature output channels, standard to the Landmark Graphic
Processor. Each function has both a current output, either 0 to
20mA or 4 to 20mA, and a single relay alarm output.
Math Functions have an almost unlimited range of uses in applications
such as trending, cross-product uniformity, hot edge detection etc.
SERIAL COMMUNICATIONS
RS232C and RS485 serial communications are included with the
Math Function option for the LANDMARK® GRAPHIC processor.
A serial option is also available for users who do not require
Math Functions.
Serial communications provide a remote interface between the
processor and the process control computer. The serial
communications circuitry connects directly to the internal
microprocessor, via which it has access to all the data in the
LANDMARK® GRAPHIC.
A single option card can input any parameter for any fitted channel
card, and retrieve all existing settings along with the temperature
data and system status information for any fitted channel card.
EASY CONFIGURATION
LANDMARK® GRAPHIC is easy to configure using the text
based, setup menu system which is switch selectable in different
languages; English, French, German, Italian, Spanish and
Japanese. Once the thermometer type has been entered, the
processor automatically configures the appropriate input data.
You can then select the required temperature span for the output
current range, target emissivity/non greyness values and a
range of time functions and alarm settings to match your exact
needs.
All parameter settings are entry code protected.
Customer connections are also made as easy as possible, using
two-part demountable terminal strips located on the rear panel.
The modular construction of SYSTEM 4 ensures that any system
expansion is catered for with ease.
GRAPHICAL DISPLAY AND KEYPAD
The LCD panel features a large 320 x 240 pixel display, providing
a high quality visual interface with the system.
The tactile keypad enables easy configuration of the processor
with thermometer and process variables.
Help and error messages simplify setup and operation.
The cold cathode back-lit LCD panel provides a display of
measured temperature in numeric or graphic formats, presenting
useful profile or trending data. The LCD panel provides a choice
of numeric, line chart, deviation chart or mixed displays.
Inputs from up to four individual thermometers can be displayed
simultaneously as 4 channel numeric, 4 channel bar graph or 4
channel deviation bar graph.
REAL TIME PROCESSING
A fully featured and real time Peak Picker is used when
measuring the temperature of intermittent targets, or where the
hot target surface is obscured by cool areas such as scale on
rolled steel.
Landmark® Graphic Processor display and keypad
Fast input sampling by the Peak Picker, combined with a built-in
spike protection filter allows the processor to respond quickly to a
rise in temperature signal from the thermometer.
The user settings also includes a threshold value which, together
with On/Off delay timers and two distinct modes of operation,
allow configuration to deal with the most demanding of
applications.
An Averager is used to smooth any rapid fluctuations in the
process value or reading to deliver a stable, time-averaged value
for process control.
The time constant is selected from 0 to 512 seconds, to give
suitable, gradual changes in the temperature display and
processor output.
If your process is intermittent or interrupted, a Track and Hold
function is provided which allows you, via an external command
signal, to Hold the required measurement value until you wish to
once again Track the variations in the process.
ALARMS
Two alarms are provided, selectable as either high or low, and
are ideal for use as ON/OFF controllers. Alarm thresholds are
selectable in 1° steps within the temperature of the thermometer.
Typical Landmark® Graphic Displays
ORDERING INFORMATION
LANDMARK® GRAPHIC has a unique model number which
describes the processor model.
The model number, consisting of the various options available,
can be used for selection and ordering purposes (see below).
MULTI-CHANNEL PROCESSOR
LMG
LANDMARK
GRAPHIC
MULTIPLE
CHANNEL
M
1
1
1
1
THERMOMETER
CHANNELS
1 = CHANNEL FITTED
0 = CHANNEL OMITTED
1
SERIAL COMMS
0 = OMITTED
1 = SERIAL MODULE
2 = MATH + SERIAL
MODULE
For example: LMG - M 1 1 1 1 - 1 is a LANDMARK® GRAPHIC
configured with four thermometer input cards with serial
communications.
ENVIRONMENTAL PROTECTION
The processor case is constructed from high quality extruded
aluminium with a die cast bezel.
An optional, clear, moulded cover panel is available. The cover
panel, designed to the requirements of IP65/NEMA 4 is removable
and provides environmental protection in hostile locations.
Multi-Channel Bar Chart Display
Landmark Graphic Processor fitted with cover panel
The Landmark® Classic is a simple,
reliable thermometer signal processing
unit, with many optional features, intended
for cost conscious temperature
monitoring and control applications.
• Rugged flexible modular design
• Proven, reliable electronics
• Optional time function and alarm modules
• Industry standard 4 to 20mA output to suit all
industries and control systems
LANDMARK® CLASSIC is a modular, flexible processor, fully
compatible with the entire range of SYSTEM 4 thermometers.
The processor provides the necessary power and control
signals required by the thermometer for either emissivity or non
greyness compensation. It has an LCD display of temperature
and parameter variables.
The processor accepts the input signal from the SYSTEM 4
thermometer, provides a display of temperature and retransmits
the signal as an industry standard 4 to 20mA output either
directly to your process control system, or via optional time
function and alarm modules.
LANDMARK® CLASSIC can be configured with
either a peak picker or averager time function, and up to two
alarm modules which may be selected at the time of purchase or
retrofitted in the field. There is no requirement for recalibration
on subsequent change of options installed.
The modular design of LANDMARK® CLASSIC gives you
maximum flexibility on the choice of processing requirements for
your application.
This ensures that your temperature measurement system can be
adapted to suit all applications, whatever the specific
requirements.
EASY CONFIGURATION
Configuration is simple and quick. The measurement range is
scaled to suit the particular type of thermometer in use via span
and offset controls on the front panel.
Built-in reference sources enable processor calibration without
any external test equipment.
Switches are provided for thermometer series, units (°C or °F)
and emissivity or non greyness.
Landmark Classic Processor fitted with Alarms and Peak Picker function
DISPLAY
The large, easy to read LCD panel provides a continuous
display of measured temperature, together with over and under
range indications.
Alarm and emissivity or non-greyness settings are displayed at
the press of a button.
REAL TIME PROCESSING
A fully featured and real time Peak Picker is used when
measuring the temperature of intermittent targets, or where the
hot target surface is obscured by cool areas such as scale on
rolled steel.
Fast input sampling by the Peak Picker, combined with a built-in
spike protection filter allows the processor to respond quickly to
a rise in temperature signal from the thermometer.
The Peak Picker has a user adjustable decay rate and both
manual and remote reset controls, giving flexibility to deal with
the most demanding of applications.
An Averager is used to smooth any rapid fluctuations in the
process value or reading to deliver a stable, time-averaged
value for process control.
The time constant is selected from 0 to 512 seconds, to give
suitable, gradual changes in the temperature display and
processor output.
ALARMS
Two alarms are provided, selectable as either high or low, and
are ideal for use as ON/OFF controllers. Alarm thresholds are
adjustable in 1° steps within the temperature of the thermometer.
ENVIRONMENTAL PROTECTION
Landmark Classic Processor fitted with cover panel
The processor case is constructed from high quality extruded
aluminium with a die cast bezel. An optional, clear, moulded
door panel is available. The door panel, designed to the
requirements of IP65/NEMA 4, is removable and provides
environmental protection in hostile locations, as well as a
degree of tamper proofing.
ORDERING INFORMATION
LANDMARK® CLASSIC has a unique model number which
describes the processor model. The model number, consisting
of the various options available, can be used for selection and
ordering purposes.
LMC
LANDMARK
CLASSIC
A
A
P
ALARM 1 ALARM 2
TIME FUNCTION
A = FITTED
A = AVERAGER
P = PEAK PICKER
O = OMITTED
0 = NOT FITTED
For example: LMC-A-A-P is a LANDMARK® CLASSIC processor
with alarms 1 and 2, and peak picker modules fitted.
LANDMARK® TECHNIC is a high
precision, digital, DIN-rail mounted
signal processing unit, providing
economic conditioning of any System
4 thermometer output signal - ideal for
both end user and OEMs.
• Standard DIN-rail mounting - requires no panel
space
• Time functions - average, peak picker and track
and hold as standard
• Industry standard 4 to 20mA output
• Remote input for Track and Hold
• Emissivity/non-greyness adjustment
• Alarm output
• Set up performed using a PC and configuration
software
• Indicator (LMi) and power supply are also available
Landmark Technic Processor and System 4 thermometer
LANDMARK® TECHNIC has standard electrical outputs and is
DIN-rail mounted for easy integration into OEM's and end user
process control systems.
RS232C serial communications are included providing a remote
interface between the processor and a PC for configuring the
system parameters.
REAL TIME PROCESSING
Landmark Technic Processor connections
The Averager function is used to smooth unwanted variations or
rapidly fluctuating changes in the measured signal. The Averager
time constant can be adjusted from 50ms to 512s (63%) in 15
steps.
CONFIGURATION
The Peak Picker function is used when measuring the temperature
of intermittent targets or where the hot target surface is obscured by
cool areas. The Peak Picker decay rate is adjustable from 0.25°/s
to 512°/s in 12 steps.
The PC is connected to the RS232C port on the LM Technic
front panel to perform the configuration.
The Track and Hold function is also provided with remote reset via
voltage free relay or switch contacts.
POWER SUPPLY
The DPU power supply unit provides the power supply (30V d.c.
nominal) which the LANDMARK® TECHNIC processor requires.
The DPU can be DIN-rail mounted alongside the LANDMARK®
TECHNIC. Several models are available to cover all input
voltages.
LANDMARK® INDICATOR
The LMi is an easy to read digital panel meter providing
continuous indication of measured temperature. Up to two alarms
(high or low) may be set, providing a voltage free relay output. A
visual display on the front panel indicates when an alarm has
been tripped. Alarm thresholds are set via the front panel.
It also provides scaleable 4 to 20mA output to match the input
range of your process control system.
The temperature measurement system is readily configured
using the LM Technic Configuration Software and a PC.
Once configured, the PC is disconnected from the LM Technic
and the LM Technic can be left to operate. The system
configuration is stored in non volatile memory.
LANDMARK® BASIC is a simple, low
cost, DIN-rail mounted signal
processing unit, providing economic
conditioning of any System 4
thermometer output signal - ideal for
both end user and OEMs.
• Standard DIN-rail mounting - requires no panel
space
• Time functions - average and peak picker as
standard
• Provides easy access to your thermometer's
emissivity/non-greyness control
• Digital panel meter with alarm is available (LMi)
• Industry standard 4 to 20mA output to suit all
industries and control systems
LANDMARK® BASIC has standard electrical outputs and DIN-rail
hardware, designed to allow easy integration into OEM's and
end user process control systems.
Landmark Basic Processor and DPU Power Unit
Landmark Basic Processor and DPU connections
DIN Rail Mounted
Power Supply Unit - DPU
and Basic Processor
4-20mA out
LANDMARK® BASIC enables adjustment of emissivity/nongreyness and time functions from your control room - not out on
your sensor.
LMi Indicator
LANDMARK® BASIC signal processing features an adjustable
averager and peak picker with remote reset.
Thermometer
REAL TIME PROCESSING
The Averager function is used to smooth unwanted variations or
rapidly fluctuating changes in the measured signal.
A.C. Power Supply
The Averager time constant can be adjusted, via the control
mounted on the front of the BASIC processor, from 175ms to 4s
(10 to 90%).
The Peak Picker function is used when measuring the temperature
of intermittent targets or where the hot target surface is obscured by
cool areas. The Peak Picker decay rate is adjustable from 1 to
5000% of span per second. A remote reset function is provided
from voltage free relay or switch contacts.
POWER SUPPLY
The DPU power supply unit provides the power supply (30V d.c.
nominal) which the LANDMARK® BASIC processor requires. The
DPU can be DIN-rail mounted alongside the LANDMARK®
BASIC. Several models are available to cover all input voltages.
LANDMARK® INDICATOR
The LMi is an easy to read digital panel meter providing
continuous indication of measured temperature.
Up to two alarms (high or low) may be set, providing a voltage
free relay output. A visual display on the front panel indicates
when an alarm has been tripped. Alarm thresholds are set via
the front panel.
It also provides scaleable 4 to 20mA output to match the input
range of your process control system.
Peak Picker
Reset
Landmark Basic Processor controls
SPECIFICATIONS
Landmark Graphic
Landmark Classic
Landmark Technic
Landmark Basic
Display
Cold cathode, backlit,
320 x 240 pixels
LCD
Optional LMi Indicator
Optional LMi Indicator
Outputs
4 to 20mA, 0 to 20mA, 1mV/°
4 to 20mA over temperature range
0 to 20mA or 4 to 20mA
4 to 20mA over temperature range
10ms
5ms to 98%
(without time function module)
10ms
3ms to 98%
(time functions at minimum)
0.050 to 1.000 in 0.001 steps**
0.20 to 1.00
0.200 to 1.000 in 0.001 steps
0.20 to 1.00
Output update
Emissivity
Non Greyness
0.800 to 1.250 in 0.001 steps
0.800 to 1.250
0.800 to 1.250 in 0.001 steps
0.800 to 1.250
Peak Picker
Yes
Optional
Yes
Yes
Averager
Yes
Optional
Yes
Yes
Track and Hold
Yes
No
Yes
No
Alarms
Yes
Optional
Yes
No
Optional
No
Yes
No
Serial Comms.
Power requirement 90 to 132V a.c. or 180 to 264V a.c 90 to 132V a.c. or 180 to 264V a.c
48 to 63 Hz, 35VA
30V d.c. nominal
48 to 63 Hz, 35VA
24 to 30V a.c. 50 to 60Hz
or 30 to 45V d.c at 200mA
(290VA max with 4 thermometers)
Ambient operating
temperature
Sealing
5 to 50°C (specified)
5 to 60°C (max. operating)
To requirements of IP65/NEMA4 (with optional cover fitted)
Humidity
0 to 99% non condensing
Vibration
Weight
1g any axis, 10 to 300Hz
5.5kg approx.
4.3kg approx.
CE
Thermometers
0.5kg approx
0.2kg approx.
EN 50-082-2 (immunity), EN 50-081-1 (emission), IEC 1010 (safety)
System Accuracy
(1)
IP40, IP20 to terminals
Repeatability*
Accuracy*
Repeatability*
Accuracy*
Repeatability*
Accuracy*
Repeatability*
Accuracy*
M1 450/1000C
<1K
0.4%K
<1K
0.5%K
<1K
0.4%K
<1K
0.6%K
M1 600/1600C
<1K
0.25%K
<1K
0.5%K
<1K
0.25%K
<1K
0.6%K
M1 800/2600C
<2K
0.4%K
<2K
0.75%+1K
<2K
0.4%K
<2K
0.9%+1K
M2 300/1100C
<1K
2K
<1K
0.25%+2K
<1K
2K
<1K
0.4%+2K
M3 50/250C (1)
<1.5K
2K
<1.5K
3K
<1.5K
2K
<1.5K
4K
M4 50/250C (1)
<1K
3K
<1K
3.5K
<1K
3K
<1K
4K
M4 150/550C
<1K
3.5K
<1K
4.5K
<1K
3.5K
<1K
5.5K
M5 400/1300C
<1K
0.35%K
<1K
0.7%K (2)
<1K
0.35%K
<1K
0.75%K (2)
M5 1000/2500C
<1K
0.5%K
<1K
0.6%K
<1K
0.5%K
<1K
0.65%K
M6 0/300C
<1K
2K
<1K
0.3%+2.5K
<1K
2K
<1K
0.4%+2.5K
M6 100/700C
<1K
2K
<1K
0.3%+2.5K
<1K
2K
<1K
0.4%+2.5K
M7 25/375C (1)
<1.5K
2K
<1.5K
3K
<1.5K
2K
<1.5K
4K
M8 0/1000C
<1K
3.5K
<1K
4.5K
<1K
3.5K
<1K
5.5K
R1 600/1600C
<1K
0.45%K
<1K
0.7%K
<1K
0.45%K
<1K
0.75%K
R1 1000/2600C
<2K
0.75%K
<2K
1.1%K
<2K
0.75%K
<2K
1.2%K
(2)
Above 75°C
Optimised for glass toughening = 3K at 630°C
* For a definition of 'Repeatability' and 'Accuracy', refer to Land document 'NDA 478'
** Systems are functional, but performance is unspecified at emissivity values <0.200.
System 4 THERMOMETERS offer
exceptional flexibility with a choice of
single wavelength, ratio, fibroptic and
fibroptic ratio models.
Thermometer type, temperature range,
spectral response and optical
characteristics are chosen to suit any
application from 0 to 2600°C.
• Focusable optics - guaranteeing 98% of target
energy within the lens graticule. Optics remain
focusable during operation
• Additional close-up lenses for 'standard bodied'
thermometers for targets as small as 0.45mm
• Flexible fibre optics light guide versions - with
optional laser targeting system to define target
size and position
• Traceable, individual calibration - giving flexible
systems with unrestricted interchangeability
• Long term accurate, reliable and drift-free
measurement
• Rugged design with a wide range of mounting
accessories
STANDARD BODIED THERMOMETERS
Proven reliable electronics and a high quality optical system are
housed in a rugged die-cast aluminium body with a robust
electrical connector to provide reliable performance.
All thermometers feature through-the-lens sighting.
Adjustable focus with a circular graticule gives precise alignment
on to the smallest of targets. Two optical variants are available:
Standard and Short-focus.
System 4 Standard Bodied and Fibroptic Thermometers
M1 Thermometers
M1 thermometers are intended for general purpose use in high
temperature applications from 450 to 2600°C. They utilize a silicon
cell detector and operate at short wavelengths and have a fast
response time of 5ms to 95%.
M2 Thermometers
M2 thermometers use the latest generation of germanium detectors
and operate at a wavelength of 1.6µm. They extend the
measurement range of short wavelength thermometers down to
300°C and have a fast response time of 5ms.
M4 Thermometers
M4 thermometers measure from 50 to 550°C and are used on low
temperature, partially obscured, low or uncertain emissivity surfaces
such as bright or unoxidized metals. They use lead sulphide
detectors in a unique null balance mode to guarantee stability.
M5 Thermometers
The fast speed of response, coupled with small target size and
accurate sighting facility make the M5 thermometers ideal for all flat
glass, glass toughening and optical fibre preform applications. They
measure from 400 to 2500°C.
M6 Thermometers
The unique M6 short wavelength thermometers measure from 0 to
700°C and are designed specifically for lower temperature
applications such as metal processing, glass lehr, food, paper,
rubber and textiles.
M7 Thermometers
M7 thermometers operate at a waveband selected especially for
measurement on plastic films as thin as a few microns, such as
Polyethene and PVC, and measure from 25 to 375°C.
M8 Thermometers
M8 thermometers measure from 0 to 1000°C and are ideal for
applications such as food, textiles, paper and plastics. They operate
at a waveband which avoids the effects of atmospheric absorption.
R1 Ratio Thermometers
R1 Ratio Thermometers are intended for difficult, high temperature
applications where the field of view is not fully filled or where the
sight path is obscured. Their range is 600 to 2600°C and can
accurately measure temperature of targets with up to 95%
obscuration.
FIBROPTIC THERMOMETERS
Fibroptic models have a flexible fibre optics light guide which
enables the detector and electronics enclosure to be located in a
less hostile environment.
Fibroptic M1 Thermometers
Fibroptic M1 thermometers measure from 600 to 2600°C and
combine the flexibility of fibre optics with short wavelength
operation. They can be used in high temperature applications such
as metals, glass, coke ovens and induction heating.
Fibroptic M2 Thermometers
Fibroptic M2 thermometers are designed for applications from 300
to 1100°C, such as glass mould temperatures where access to the
target is restricted, or limited to a few milliseconds.
Fibroptic M3 Thermometers
The Fibroptic M3 thermometers is designed for low temperature
applications, with low or uncertain emissivity, such as secondary
metals, within the range 50 to 250°C.
Fibroptic R1 Ratio Thermometers
Fibroptic R1 ratio thermometers measure from 600 to 2600°C and
provide accurate high temperature measurement of small
intermittent targets, such as rod and wire, and tube welding. Other
typical applications include kilns and vacuum furnaces.
THERMOMETER MOUNTINGS AND ACCESSORIES
To enable you to measure temperature
accurately in even the most severe
operating conditions, a complete range
of thermometer protection and
mounting accessories is available.
Full mechanical and thermal protection for the thermometer and
electrical connections is ensured, giving undisrupted service with
minimal maintenance in almost any environment.
JACKET
The corrosion resistant thermometer jacket provides air or water
cooling where excessive heat may exist.
The jacket allows quick, no-tools thermometer installation and
removal and ensures reproducible alignment.
END CAP
The end cap provides protection for the rear of the thermometer.
The ingenious design, featuring a pre-wired thermometer
connector and a terminal strip inside the end cap simplifies
customer connections on-site.
MOUNTING PLATES
Mounting plates enable the thermometer, together with a jacket,
purge and sighting tube, to be securely mounted in a safe
position to monitor the product or process.
O/N/M mounting plate is a simple, rugged mounting which can be
used with all of the sighting tubes.
O/N/AF adjustable mounting
plate is for use where accurate
sighting is essential. The
jacket/ purge fastens to an
adjustable circular plate. The
O/N/AF mounting is used with
the FS6 and FS36 sighting
tubes.
FIBROPTIC MOUNTINGS AND ACCESSORIES
THERMOMETER CONNECTOR
QUICK-RELEASE AND AIR PURGE ASSEMBLY
The thermometer connector is normally supplied pre-wired and
terminated in the end cap. A connector pre-wired to 4m of cable
must be ordered if the user does not require an end cap for the
application.
The quick release and air purge/sighting tube assembly attaches
to the optic head of the fibroptic thermometer to keep the lens
clean.
AIR PURGE
Extensive research has resulted in a highly efficient air purge
which keeps condensation, dirt and other deposits off the
thermometer lens. The air purge also helps to disperse fumes
and smoke from the thermometer sight path.
The purge accepts a range of air entry adapters and fittings, and
has the added bonus of being suitable for use with both fan or
compressed air supplies.
The front flange of the purge also mounts directly onto the Land
System 3 range of mounting plates and sighting tubes.
SIGHTING TUBES
The assembly can be used with a range of mounting
accessories.
MOUNTING PLATE
ASSEMBLY
A simple, robust 127mm diameter
mounting plate and quick release/air
purge assembly permits a range of
mounting options.
ANGLE MOUNTING BRACKET ASSEMBLY
A simple mounting bracket serves as an inexpensive mounting for
the thermometer optic head. The bracket is designed for bolting
to almost any mounting surface.
A range of Silicon Carbide, Sillimanite and Stainless Steel
sighting tubes are available in various lengths up to 1200mm for
use in temperatures up to 1550°C.
ADJUSTABLE MOUNTING FLANGE ASSEMBLY
Open ended sighting tubes (Type STO) are used to ensure a
clear view of a solid target through flame, smoke, fumes and dust.
Closed-end sighting tubes (Type STC) are used to measure the
temperature of a fluid material.
ADJUSTABLE MOUNTING PLATE
The adjustable mounting flange and quick release/air purge
assembly provides accurate alignment of the optic head.
An adjustable mounting flange allows alignment of the optic head
at any angle up to 45°.
For more details of Land Thermometer Mountings and Accessories, please refer to brochure ref. S4M100E
THERMOMETER MOUNTINGS AND ACCESSORIES
Both the Standard bodied and Fibroptic range of mounting
accessories are subdivided into three groups which cover all
environmental conditions i.e. INDUSTRIAL, NON-HOSTILE and
LABORATORY.
NON-HOSTILE
Where the environmental conditions which apply to the
measurement application are less severe.
INDUSTRIAL
To be used where severe or extreme environmental conditions
prevail.
No adverse environmental conditions prevail, a requirement for
thermometer mounting only.
LABORATORY
Industrial
Jacket
S4 J
(Pt. Nº 091.560)
Non-Hostile
Laboratory
Note: Several mountings are common to more than one system
End Cap
S4 C
(Pt. Nº 091.562)
Sighting Tube
STO
Flanged Window
S4 W
(Pt. Nº 091.812)
Air Purge
S4 P
(Pt. Nº 091.807)
Mounting Plate
O/N/AF
(Pt. Nº 095.168)
Thermometer
Mounting Bracket
S4 MB
(Pt. Nº 029.226)
Mounting Plate
O/N/M
(Pt. Nº 095.091)
Small Ball Mount
S4 B
(Pt. Nº 150.560)
Sighting Tube
STC
Mounting Adapter
S4 MA
(Pt. Nº 029.264)
Water Cooled Flange
S4 WF
Mounting Plate
(Pt. Nº 029.547)
S4 MP
Light Air Purge
S4 LP
(Pt. Nº 91.811)
Large Ball Mount
S4 LB
(Pt. Nº 030.566)
(Pt. Nº 029.263)
Industrial
Non-Hostile
Laboratory
Note: Several mountings are
common to more than one
system
Detector Module
Adapter, Air Purge &
Mounting Plate
(Pt. Nº 029.872)
Adapter, Air Purge &
Adjustable Mounting Flange
(Pt. Nº 029.871)
Adapter & Air Purge
(Pt. Nº 029.870)
Hinged Adjustable
Mounting Plate
(Pt. Nº 199.077)
L & N/Honeywell Adapter
(Pt. Nº 199.051)
Adapter, Air Purge &
Mounting Bracket
(Pt. Nº 029.873)
Lightguide
(Choice of 3 lengths)
Optic Head
(Choice of 3 focal variants)
Fibroptic Angle Bracket
S4 FB
(Pt. Nº 029.224)
Large Ball Mount
S4 LB
(Pt. Nº 030.566)
Fibroptic Adapter
S4 FA
(Pt. Nº 029.238)
Small Ball Mount
S4 B
(Pt. Nº 150.560)
For more than fifty years LAND have supplied temperature measuring and process imaging
systems to many different industries all over the world. Now the world leader in non contact
thermometry, our expert advice and support is never far away.
WORLD LEADERS
WORLDWIDE SUPPORT
LAND is the world leader in the
manufacture of non contact
temperature measurement
systems, thermal imagers and
linescanners.
WORLDWIDE
SUPPORT
In addition to the companies
established in Europe, USA,
Mexico and Japan, LAND is
represented by distributors in
most of the major industrial
countries throughout the world.
Our customers benefit, on a
global basis, from practical and
expert advice from fully trained
technicians who are aware of
specific requirements for their
country and industry.
Expert advice and support is never far away
APPLICATIONS
CALIBRATION
LAND have solved many different temperature measurement problems in a wide variety of industries
from food to atomic energy, some of which are list below:
LAND operate an extensive
calibration
service.
All
calibrations made are traceable
to
National
Standards.
Calibration certificates are
available from our UKAS
accredited calibration laboratory
0034.
•
•
•
•
•
Iron & Steel
Petrochemical
Heat Treatment
Minerals
Glass
•
•
•
•
•
Maintenance
Power & Utilities
Aerospace
Electronics
Pharmaceuticals
•
•
•
•
•
Plastics
Paper
Rubber
Textiles
Non-ferrous Metals
For further information or free advice on specific temperature measurement problems within these or
any other industry, contact your nearest Land office.
PRODUCT ASSURANCE
When you specify LAND products you are assured of receiving a completely pretested, calibrated
working product. Each instrument is carefully checked to ensure complete compliance with specification
and is fully guaranteed. LAND was the first manufacturer of infrared instruments to successfully obtain
ISO 9001 Quality Management System Approval for both design and manufacture of non contact
infrared temperature measuring equipment.
A
In the USA a traceable
calibration certificate can be
issued complying with the
National Institute of Standards
and Technology (NIST).
A consultancy service is also
available for those companies
who wish to establish their own
in-house calibration facility.
These products comply with current European directives relating to electromagnetic compatibility
and safety (EMC directive 89/336/EEC; Low voltage directive 73/23/EEC).
The Quality Management System of Land Instruments International Ltd. is approved to BS EN ISO9001:2000
for the design and manufacture, stockholding, in-house repair and site servicing of non contact temperature
measuring instrumentation. Associated software designed and developed in accordance with TickIT.
Calibration certificates are available from our UKAS accredited Calibration Laboratory No. 0034. The Land
calibration laboratory complies with the requirements of the international standard BS EN ISO/IEC 17025.
abc abcdefg
Land Instruments International • Dronfield S18 1DJ • England • Tel: (01246) 417691 • Fax: (01246) 410585
Email: infrared.sales@landinst.com • Internet: www.landinst.com
Land Instruments International • 10 Friends Lane • Newtown, PA 18940-1804 • U.S.A. • Tel: (215) 504-8000
Fax: (215) 504-0879 • Email: irsales@landinstruments.net • Internet: www.landinstruments.net
Printed in England
France
Land Instruments Sarl
Tel: (1) 34 62 05 45 • Fax: (1) 30 56 51 12
Email: commercial@landinst.fr
Germany
Land Instruments GmbH
Tel: 02171/7673-0 • Fax: 02171/7673-9
Email: infrarot@landinst.de
Italy
Land Instruments Srl
Tel: 02/99040423 • Fax: 02/99040418
Email: infrared@landinst.it
Japan
Land KK
Tel: 06 6330 5153 • Fax: 06 6330 5338
Email: ikeland@silver.ocn.ne.jp
Spain
Land Instruments International
Tel: 91 630 0791 • Fax: 91 630 2918
Email: land-infrared@landinst.es
Mexico
Land Instruments International
Tel: 52 55 9171 1466 • Fax: 52 55 9171 1477
Email: ventas@landinstruments.net
Continuous product development may make it necessary to change these details without notice.
S4P101E/0303
abc
THERMOMETER
MOUNTINGS AND ACCESSORIES
abc abcdefg
abc
The new Standard Bodied and Fibroptic range of temperature measurement systems from Land Infrared includes a
comprehensive range of thermometer mounting and protection accessories to suit any measurement environment. All mountings
and accessories feature quick and tool-free installation and removal. The range of accessories can be sub-divided into three
groups INDUSTRIAL, NON-HOSTILE and LABORATORY. These groups provide a classification which equate to the given
environmental conditions.
SELECTING MOUNTINGS AND ACCESSORIES
The following information will help determine which specific mountings and accessories are necessary to maintain
measurement accuracy and reliability of performance of the thermometer.
Cooling Jacket - Standard Thermometers
The thermometer cooling and protection jacket provides benefits where there is a requirement for:
• Thermal protection of the thermometer i.e high ambient temperatures
• Mechanical protection of the thermometer i.e risk of damage
• Full environmental protection of the thermometer i.e water or smoke ingress
End Cap - Standard Thermometers
The End Cap provides benefits where there is a requirement for:
• Full environmental protection of the thermometer electrical connections i.e water ingress
Air Purge
The Air Purge clears dust, steam and smoke from the thermometer sight path to ensure accurate temperature measurement.
An Air Purge is required to:
• Clear the sight path
• Prevent build-up of debris on the thermometer lens
• Protect the lens from flame or gas impingement
Mounting Bracket/Plate/Adapter
The range of brackets, plates and adapters are used where there is a need for:
• Fixed, robust installation
• Thermal protection
• Mechanical protection
• Angular adjustment (accurate sighting)
Sighting Tubes
Sighting Tubes are used for:
• Viewing the target through flame, smoke, fumes etc.
INDUSTRIAL For full details of Standard Body INDUSTRIAL Mountings and Accessories refer to pages 4 - 7.
For Fibroptic INDUSTRIAL Mountings and Accessories, refer to pages 12 and13.
To be used where severe or extreme environmental conditions prevail.
• High or low ambient temperatures
• Smoke, steam, fumes present in the atmosphere i.e. requirement for thermometer purge
• Exposure to exceptional environmental conditions i.e. inside a furnace
• Potential damage from personnel or other equipment
NON-HOSTILE For full details of Standard Body NON-HOSTILE Mountings and Accessories refer to pages 8 and 9.
For Fibroptic NON-HOSTILE Mountings and Accessories refer to page 14.
Where the environmental conditions which apply to the measurement application are less severe i.e. Non-Hostile.
• Room temperature operating conditions i.e. none or minimal requirement for thermometer cooling
• Absence of large amounts of smoke, steam, fumes etc i.e potential for air purging to maintain accuracy of reading only
• No unusual environmental conditions
• No possibility of damage from personnel or other equipment i.e no requirement for heavy-duty mountings
LABORATORY For full details of Standard Body LABORATORY Mountings and Accessories refer to page 10.
For Fibroptic LABORATORY Mountings and Accessories refer to pages 14 and 15.
No adverse environmental conditions prevail, a requirement for thermometer mounting only.
AIR SUPPLY SYSTEMS For full details of AIR SUPPLY SYSTEMS refer to page 15.
Note: Pt. No. - Land Part Number code - please specify when enquiring or ordering.
All dimensions are given in inches.
2
COMPLETE STANDARD BODIED THERMOMETER SYSTEMS
INDUSTRIAL
To
Processor
Target
Sighting Tube
Mounting Plate
Air Purge
Jacket
End Cap
NON-HOSTILE
Water-cooled Flange
Thermometer
Mounting Shoe
To Processor
Target
Mounting Adapter
Light Purge
Large Ball Mounting
LABORATORY
Thermometer
Target
To Processor
Small Ball Mounting
3
4
Mounting Plate
O/N/M
(Pt.-Nº 095.091)
Mounting Plate
O/N/AF*
(Pt.-Nº 095.168)
Note
The O/N/AF Mounting Plate must not
be used with either silicon carbide or
silimanite sighting tubes, or any
sighting tubes with outside diameter
greater than 2.2in
Sighting Tube
STO or STC
(STC shown)
Sighting Tube
STO or STC
(STO shown)
Air Purge
S4 P
(Pt.-Nº 091.561)
Air Inlet
Mounting Plate
S4 MP
(Pt.-Nº 029.263)
Flanged Window
S4 W
(Pt.-Nº 091.812)
Air/Water Inlet/Outlets
End Cap
S4 C
(Pt.-Nº 091.562)
Large Ball Mounting
S4 LB
(Pt.-Nº 030.566)
Mounting Adapter
S4 MA
(Pt.-Nº 029.264)
Jacket
S4 J
(Pt.-Nº 091.560)
Thermometer
INDUSTRIAL
THERMOMETER COOLING JACKET, END CAP AND PURGE
End Cap S4 - C (Pt.No. 091.562)
Cooling Jacket S4 - J (Pt.No. 091.560)
The cooling jacket contains an effective air or water cooling
facility for use in environments where excessive heat may
damage or affect the thermometer. The thermometer fits inside
and is held in place by two retaining clips.
Water cooled: Flow < 1 I/min / 0.2 Gal/min
(exceeding the recommended flow may cause over-cooling
leading to condensation problems)
Air cooled: Flow < 450 I/min / 16cfm
Maximum working pressure: 700kNm2/7Bar (100psi)
The End Cap provides full environmental protection
for the electrical connections to the thermometer.
Customer connections are made to the terminal strip inside the
cap. The pre-wired thermometer connector plug is integral to
the cap.
Two Camlock fasteners secure the cap to the thermometer
jacket for use in a hostile environment.
Weight: 3.42lb
3.94
Rear Panel removed
Customer connections shown
Plain pipe connections: ø0.375
Weight: 4.85lb
140
5.51
Air/Water
Thermometer
Inlet and Outlet Retaining clips (2)
Ø0.38
4.72
Pre-Wired
Thermometer Connector
Cable entry
Ø 0.24 to 0.35
2.95
Thermometer Connector (Pt.No. 029.673)
6.7
4.72
The thermometer connector is normally prewired and terminated
in the end cap. A connector prewired to cable must be ordered
if the user does not require an end cap.
Mounting holes underside of S4 J Jacket
Two holes (M6 x 1P) in the base of the Cooling Jacket (S4 J)
permit mounting directly to a flat surface or to an alternative
mounting i.e. S4 MA or MP.
Air Purge S4 - P (Pt.No. 091.561)
2.95
2.76
Air purge units use a stream of clean air to keep condensation,
dirt and other deposits from the thermometer lens/window.
The air stream also helps to disperse steam, fumes or smoke
from immediately in front of the thermometer. The units are
robust, trouble free and easily fitted between jacket and
mounting plate or straight onto the jacket if a universal
mounting is used. The only requirement is clean and dry air
supply.
Inlet pressure: 350N/m2 / 3.5mBar (0.05 psi)
Flow rate: 60I/min / 2cfm< 2cfm
Pipe thread: G1 (BS), for fan air supply
Weight: 3.2lb
Assembly
16.54 approx.
5.55
Ø4.60
Air Inlet G1(BS)/1in BSP
5.91
2 Holes
M6 x 1P thread
To
Processor
Air Purge
Ø2.09
Total Weight 15.2lb
5
Jacket
(+ Thermometer)
End Cap
THERMOMETER MOUNTINGS AND BRACKETS
Adjustable Mounting Plate O/N/AF (Pt.No.095.168)
Mounting Plate O/N/M (Pt.No.095.091)
The jacket or purge fastens to a circular plate, which with the
adjustment of four screws can move up to 7.5° with respect to
the main plate. For use where accurate sighting is essential.
Weight: 11lb
This plate is not suitable for use with either silicon carbide
or sillimanite sighting tubes.
The mounting plate has four fixing holes, three studs for the
jacket or purge, and a centre thermometer hole. It is ideal for
mounting System 4 thermometer systems.
Weight: 8lb
4 holes 0.55
on 10 PCD
4 holes 0.55
on 10 PCD
9.02Sq
1.14
3.25 dia
9.02 Sq
Adjuster
screws
2.36 dia
3 bolts/studs ¼in BSW
on 3.84 PCD
0.39
0.39
3 studs ¼in BSW
on 3.84 PCD
Large Ball Mounting S4 LB (Pt.No. 150.577)
Mounting Adapter S4 MA (Pt.No. 029.264)
The ball mounting is used with the Mounting adapter (S4 MA).
Four holes permit fixing to flat surface. A locking handle
secures the ball mount at the required orientation for accurate
sighting.
When the ball mounting is used with the cooling jacket this
adapter provides a stable plate on which to attach the jacket.
2 holes CSK Ø0.41
1 hole M12 x 1.5P
0.45
4.13
2.05
2.83
3.94
Locking
handle
2.99
0.28
1.57
1.18
4.02
Mounting Options
A Jacket (S4 J)
B Large Ball Mount (S4 LB)
Mounting Plate S4 MP (Pt.No. 029.263)
4 holes Ø0.35
0.47
2.56
The mounting plate can be used to mount the jacket to a flat
surface using holes A. It has holes at centers identical to those
of the jacket (B). Two ¼in BSW , ½in long screws (112.467)
are supplied with the plate to secure it to the jacket.
2 holes Ø0.41
1.73
2.66
0.45
5.91
7.09
5.91
2 holes C/L Ø0.28
Mounting Options
A Mounting Holes
B Jacket (S4 J)
6
WINDOW ASSEMBLY AND SIGHTING TUBES
Sighting Tube Information
Sighting Tubes
Sighting tubes are made from metal or refractory materials and
are either open ended (Type STO) or closed (Type STC).
Type STO tubes are used when viewing a solid target through
flame, smoke, fumes etc. The closed end of the type STC tube
is used as the target. A thermometer used with an STC tube
can replace a sheathed thermocouple.
To attach the sighting tubes to a mounting plate a steel adapter
(Type STA) is cemented into refractory sighting tubes.
The STA is drilled to fit the studs on the mounting plate
(O/N/M).
Replacement Sighting Tubes can be purchased without the
STA adapter fitted. Contact Land Infrared for details.
There are 3 types of tube material with varying lengths.
For exact dimensions and ordering references please refer to
the table adjacent.
Type
Silicon Carbide Tubes (STO & STC)
These are either open ended or closed, and can be used in
temperatures up to 2700°F/1500°C. They have high mechanical
strength, good resistance to thermal shock and very high
thermal conductivity.
Dimensions in
L
OD
ID
Adapter
Type
Part No.
STA
STA
STA
STA
STA
091.410
091.411
091.412
091.413
091.414
Silicon
Carbide
STC
17.7
23.6
29.5
35.4
41.3
3.0
3.0
3.0
3.0
3.0
2.5
Silicon
Carbide
STO
17.7
23.6
29.5
35.4
41.3
3.0
3.0
3.0
3.0
3.0
STA
STA
STA
STA
STA
091.415
091.416
091.417
091.418
091.419
Sillimanite
STO
Sillimanite
liner tubes
23.6
29.5
35.4
41.3
47.2
14.0
20.0
2.75
2.75
2.75
2.75
2.75
3.74
3.74
2.5
2.5
2.5
2.5
2.5
2.4
2.4
2.4
2.4
2.4
3.2
3.2
STA
STA
STA
STA
STA
-
091.420
091.421
091.422
091.423
091.424
118.270
118.271
Stainless Steel
FS6
FS36
6.0
36.0
2.25
2.25
2.12
2.12
F
F
091.458
N/S
2.5
2.5
2.5
2.5
Sillimanite Tubes (STO only)
These are suitable for use in temperatures up to 2800°F/
1550°C and are fairly resistant to thermal shock.
Sillimanite liner tubes are also available.
Window Assembly S4 W (Pt.No.091.812)
The Window Assembly is required for use on pressure vessels,
vacuum furnaces and other applications where controlled
atmospheres are encountered. Refer to Land Infrared for
suitability in a particular application.
Two versions are available:S4 W (Quartz)
Pt. No. 091.812
For System 4 M1, M2, M4 thermometers
S4 W (Fluorite)
Pt. No. 092.519
For System 4 M5, M6, M7 thermometers
and UNO U5 thermometers
Replacement seals: Pt. No. 001.431
L
I.D. O.D.
STA Adapter
Type STC Sighting Tube
L
4.69
I.D. O.D.
STA Adapter
Type STO Sighting Tube
Stainless Steel Tubes
5.51
A low temperature tube for use up to a maximum of 1470°F/
800°C. The exact temperature will depend upon length and
operating conditions. Used mainly to protect the thermometer
window from physical damage and to direct purge air along the
sight path. Stainless Steel sighting tubes come complete with
own type F adapter.
1.02
7
3.15
NON - HOSTILE
Water Inlets/Outlets
Thermometer
Air Inlet
Mounting Shoe
S4 MB
(Pt. Nº 029.226)
Waterg Cooled Flange
S4 WF
(Pt. Nº 029.547)
Light Purge
S4 LP
(Pt. Nº 091.811)
Mounting Adapter
S4 MA
(Pt. Nº 029.264)
Mounting Plate
S4 MP
(Pt. Nº 029.263)
Large Ball Mounting
S4 LB
(Pt. Nº 030.566)
THERMOMETER MOUNTINGS AND ACCESSORIES
Mounting Shoe S4 MB (Pt. No. 029.226)
The thermometer is held inside the Mounting Shoe using retaining clips similar to those on the S4 J jacket. The holes on the
front permit mounting of the S4 LP purge or S4 WF flange.
3 holes Ø0.18 equispaced as shown on3.09 PCD
3 holes Ø0.28
C
B
C
1.18
2.94
C
3.19
4.57
1.18
A
A
2.93
4.33
2 Retaining clips
5.75
Mounting Options
A Mounting Plate (S4 MP)/Mounting Adapter (S4 MA)
B Thermometer Base (To secure only)
C Water Cooled Flange (S4 WF)/Light Purge (S4 LP)
8
Mounting Adapter S4 MA (Pt.No. 029.264)
Water cooled flange S4 WF (Pt. No. 029.547)
Some applications do not require the strong physical protection
and high efficiency cooling of the S4 J jacket, but some cooling
may still be necessary to protect the thermometer. In these
circumstances the water-cooled flange is recommended. It is
mounted to the front face of the mounting shoe, and will ensure
that the internal temperature of the thermometer does not
exceed the recommended operating temperature upper limit.
Water flow: <1 I/min / 13 Gal/hr
Pipe connections: Ø0.375
When the ball mounting is used with the mounting shoe
(S4 MB), this adapter provides a stable plate on which to attach
the shoe.
1 Hole M12 x 1.5P
A
B
A
0.28
1.18
1.57
2 Holes CSK Ø0.41
0.45
2.05
2.83
3.94
Mounting Options
A Jacket (S4 MB)
B Large Ball Mount (S4 LB)
3 Holes Ø0.18 equispaced as
shown on 3.09 PCD
Tube Ø0.38
Large Ball Mounting S4 LB (Pt.No.150.577)
4.74
The large ball mounting attaches to the thermometer using the
mounting adapter (S4 MA using Mounting Option B).
Four holes (Ø0.35) permit fixing to a flat surface. A locking
handle secures the ball mount at the required orientation for
accurate sighting.
4.04
Locking Handle
2.99
4.13
4.02
0.51
Light Purge S4 LP (Pt.No. 091.811)
This small, highly efficient purge attaches to the mounting
shoe (S4 MB) and is used to keep the thermometer lens/
window clean.
Inlet pressure: 3750N/m²
Flow rate: 140 l/min
Hole: G¼ (¼in BSP)
5.91
0.47
2.56 max.
4 Holes Ø0.35
Tapped hole
G¼ (¼in BSP)
Ø2.09
The mounting plate can be used to mount the shoe to a flat
surface. It has three sets of mounting holes as specified
below.
Two ¼in BSW , ½in long screws (112.467) are supplied with the
plate to secure it to the shoe.
1.73
2.66
A B
3.15
2 Holes Ø0.41
B
Ø3.54
Mounting Plate S4 MP (Pt.No. 029.263)
3 Holes Ø0.18 equispaced as
shown 3.09 PCD
A
0.45
5.91
7.09
2 Holes C/L Ø0.28
Mounting Options
A Mounting Holes
B Jacket (S4 MB)
9
LABORATORY
Thermometer
Small Ball Mounting
S4 B
(Pt Nº 150.560)
Mounting Adapter
S4 MA
(Pt Nº 029.264)
Mounting Plate
S4 MP
(Pt Nº 029.263)
Large Ball Mounting
S4 B
(Pt Nº 030.566)
THERMOMETER MOUNTINGS AND ACCESSORIES
Large Ball Mounting S4 LB (Pt.No.150.577)
Mounting Adapter S4 MA (Pt.No. 029.264)
The large ball mounting attaches to the thermometer using the
mounting adapter (S4 MA using Mounting Option B).
Four holes (Ø0.35) permit fixing to a flat surface. A locking
handle secures the ball mount at the required orientation for
accurate sighting.
When the ball mounting is used with the thermometer this
adapter fits to the thermometer base (A) using the screws
provided, and couples using the centre hole (B) to the Large
Ball Mounting (S4 LB). Two ¼in BSW , ½in long r/head screws
(112.467) are supplied with the adapter to secure it to the
thermometer.
2 Holes CSK Ø0.41
1 Hole M12 x 1.5P
A
2.05
2.83
3.94
Mounting Options
A Jacket
B Large Ball Mount (S4 LB)
0.45
Locking handle
2.99
B
4.13
A
0.28
1.18
1.57
4.02
5.91
Small Ball Mounting S4 B (Pt.No.150.560)
4 Holes Ø0.35
The S4 B can be used with the thermometer only, for accurate
sighting. It is identical to a standard tripod mounting.
2.56 max.
¼in Tripod Wheel
3.00 max.
Tripod Clamp Wheel
3/8in Tripod bush (female)
fitted with removable
¼in adapter
Ø1.38
10
0.47
11
Optic Head
Optic Head
Optic Head
Adapter
EXISTING
SYSTEM 3
MOUNTINGS
Large Ball Mount
S4 LB
(Pt. Nº 030.566)
Fibroptic Angle Bracket
S4 FB
(Pt. Nº 029.224)
NON-HOSTILE
Optic Head
Fibroptic Adapter
S4 FA
(Pt. Nº 029.238)
Small Ball Mount
S4 B
(Pt. Nº 150.560)
LABORATORY
Adapter & Air Purge
(Pt. Nº 029.870)
Processor
Adapter, Air Purge &
Mounting Bracket
(Pt. Nº 029.873)
Adapter, Air Purge &
Mounting Plate
(Pt. Nº 029.872)
Adapter, Air Purge &
Adjustable Mounting Flange
(Pt. Nº 029.871)
Large Ball Mount
S4 LB
INDUSTRIAL
Adapter, Air Purge &
Mounting Plate
Optic Head
Light Guide
Detector Module
Target
Hinged Adjustable Mounting Plate
(Pt. Nº 028.745)
L & N/Honeywell Adapter
(Pt. Nº 028.825)
COMPLETE FIBR
OPTIC THERMOMETER SYSTEMS
FIBROPTIC
INDUSTRIAL
Quick Release Adapter, Air Purge & Adjustable Mounting Flange (Pt.No. 029.871)
The adapter, air purge and adjustable mounting flange assembly attaches to the optic head, and provides a mounting using the
four holes through the circular plate. Three studs link the main plate to a smaller plate which provide adjustment to ensure accurate
alignment on to the target surface; particularly useful when sighting onto a small target. The quick-release adapter which forms
an integral part of this assembly allows rapid, no tools removal of the optic head for routine maintenance.
Air purge flow rate: 60 litre/min (2.12ft³/min), Air purge pressure: 0.1 Atmosphere (0.1bar)
Purge air inlet
Plain pipe Ø0.25
4 holes Ø0.3 equispaced
on 4.0 PCD
Ø1.3
2.1 PCD
2.8
0.25
5.5
Ø5.0
8.5
Adapter, Air Purge & Mounting Plate (Pt.No. 029.872)
The adapter, air purge and mounting plate assembly attaches to the optic head, and provides a mounting using the four holes
through the circular plate. The quick-release adapter which forms an integral part of this assembly allows rapid, no tools removal
of the optic head for routine maintenance.
Air purge flow rate: 60 litre/min (2.12ft³/min), Air purge pressure: 0.1 Atmosphere (0.1bar)
4 holes Ø0.3 equispaced
on 4.0 p.c.d.
Purge air inlet
Plain pipe Ø0.25in
Ø1.3
2.1 p.c.d.
2.6
5.7
0.25
8.5
Ø5.0
Adapter, Air Purge & Mounting Bracket (Pt.No. 029.873)
The adapter, air purge and mounting bracket assembly attaches to the optic head, and provides mounting using the single hole
in the base of the bracket. Alternatively, the bracket will attach to the large ball-mounting (S4 LB) to provide adjustment to ensure
accurate alignment on to the target surface; particularly useful when sighting onto a small target. The quick-release adapter which
forms an integral part of this assembly allows rapid, no tools removal of the optic head for routine maintenance.
Air purge flow rate: 2.12ft³/min, Air purge pressure: 0.1 Atmosphere (0.1bar)
Purge air inlet
Plain pipe Ø0.25in
2.0
2.1 p.c.d.
Ø1.3
4.1
1 Hole Ø1.4
1 Hole Ø0.5
1.6
5.7
3.1
12
3.9
Large Ball Mounting S4 LB (Pt.No.150.577)
Quick Release Adapter & Air Purge (Pt.No. 028.870)
The ball mounting can be used with either the mounting bracket
assembly (029.873) or the fibroptic angle bracket (S4 FB) to
provide adjustable mounting for accurate sighting. A locking
handle secures the ball mount at the required orientation.
The air purge is used where a clear sight path has to be
maintained, by using the purging air to maintain the lens free
from dust, dirt etc. The purge connects to the optic head with
a quick-release adapter (supplied) which allows rapid, no tools
removal of the optic head for routine maintenance. The purge
is secured on the installation using either a mounting adapter
or plate (see below).
Air purge flow rate: 60 litre/min (2.12ft³/min)
Air purge pressure: 0.1 Atmosphere (0.1bar)
4.0
3.0
4.1
Locking
handle
Purge air inlet
Plain pipe Ø0.25in
5.9
0.5
Ø1.3
4 Holes
Ø0.4
6.0
2.6 max
2.5
8.5
Hinged Adjustable Mounting Plate (Pt.No. 028.745)
L&N/Honeywell Adapter (Pt.No. 028.825)
The hinged adjustable mounting plate enables the head/
adapter/purge assembly to be mounted securely at a fixed
location. It has 45° adjustment for accurate sighting onto the
target and can be easily adjusted at any time.
This adapter permits the optic head/adapter/purge assembly to
be mounted (using the range of holes and slots provided) onto
existing thermometer mountings (including competitors) or to
a convenient structure for sighting the measurement target
area.
4 Holes Ø0.3
3.0
2.1 p.c.d.
1 Hole Ø1.4
4.0
5.0
0.5
0.5
5.0
3 Screws M4 x 0.39
CSK/HD
Quick Release Adapter (Pt.No. 029.591)
View showing mounting holes
The quick release adapter allows no tools removal of the optic
head from the air purge or mounting for routine maintenance.
It permits a System 4 optic head to be mounted onto existing
System 3 mountings.
13
NON-HOSTILE
Large Ball Mounting S4 LB (Pt.No.150.577)
Fibroptic Angle Bracket S4 FB (Pt.No.029.224)
The Fibroptic Angle Bracket enables the optic head to be
mounted either as a stand-alone in applications which require
no purging, protection or special mounting considerations;
or with the Large Ball Mounting (S4 LB) where accurate sighting
is essential.
The ball mounting is used with the Fibroptic Angle Bracket
(S4 FB) to provide adjustable mounting for accurate sighting.
Four holes (Ø0.35) permit fixing to a flat surface. A locking
handle secures the ball mount at the required orientation.
2.6
1.9
Locking
handle
3.0
4.1
4.0
5.9
2.0
4 Holes Ø0.4
Ø0.5
1.1
2.0
2.6 max
1 Hole M12 x 1.5P
LABORATORY
2 Mounting holes Ø0.2
Small Ball Mounting S4 B (Pt.No. 150.560)
Fibroptic Adapter S4 FA (Pt.No.029.238)
The S4 B is used with the Fibroptic Adapter (S4 FA) for
mounting the optic head only, where accurate sighting is
essential. It is identical to a standard tripod mounting.
¼in Tripod thread
The Fibroptic Adapter enables the optic head to be mounted as
a stand-alone, in applications which require no purging,
protection or special mounting considerations. A single ¼in
thread bolt hole can attach to the Small Ball Mounting ( S4 B)
or a standard tripod mounting.
Two further holes in the base permit mounting to a flat surface.
Ø1.4
2 Holes Ø0.2
¼in BSW
1.1
3/8in Tripod bush (female)
fitted with removeable
¼in adapter
1.0
1.6
3.0 max.
Tripod clamp wheel
Ø1.5
14
Mounting Plate S4 MP (Pt.No. 029.263)
Thermometer and Detector Module
The thermometer and detector module has two holes on the
underside. It will mount directly onto a tripod or the Small Ball
Mounting (S4 B); or can be used with the Large Ball Mounting
(S4 LB) with the Mounting Adapter (S4 MA); or fixed to a flat
surface using the Mounting Plate (S4 MP).
The mounting plate attaches to the thermometer or detector
module using holes C, and mounts to a flat surface using holes
A or B. It is supplied with two screws (¼in BSW, ½in long
screws, 112.467) to fit the thermometer base.
2.7
2 Holes Ø0.4
6.1
C
1.7
3.2
4.5
A B
B A
C
0.5
5.9
7.1
2 Holes C/L Ø0.3
2.2
3.2
2 Mounting Holes ¼in BSW (tripod)
Mounting Options
A Mounting holes
B Mounting holes
C Detector module base
6.1
4.5
Lightguide
Electrical
connections
2 Mounting holes
2 Holes ¼in BSW (tripod)
2.2
Underside of
Detector Module
1.0
AIR SUPPLY SYSTEMS
Air purges use a stream of air to disperse dust and fumes from
the thermometer sight path and to prevent dirt settling on the
lens or window.
Clean dry air must be supplied to the purges, and jackets with
integral purge and a diffuser.
Any foreign material in the air supply will potentially block the
diffuser, reduce the purge efficiency and deposit material on
the lens or window.
To achieve the necessary cleanliness standards, the air
system should be designed to recommended guidelines.
A filter system should be fitted in every air line which feeds a
purge.
LAND can supply an automatic drain air filter system with
optional low flow alarm for use with correctly engineered
compressed air systems.
A relatively clean, dry compressed air supply of 25 to 150 lb/
in²/1.75 to 10.5 kg/cm² is required for use with the system
A/A air filter system.
System A/A/LF (Pt. No. 004.449)
System A/A/LF with Low flow alarm (Pt. No. 003.939)
System A/A/HF (Pt. No. 004.450)
System A/A/HF with Low flow alarm (Pt. No. 003.940)
Fixing Details
The following are pipe dimensions recommended for use with
the A/A system:
3/8in dia. bore up to 7m/23ft long
1/2in dia. bore 7m to 27m/23ft to 90ft long
3/4in dia. bore 27m to 210m/90ft to 700ft long
19.1
3.7
1.2
11.7
G 3/8
System A/A (LF and HF)
There are two types of restrictor available; low flow (LF) and
high flow (HF). Low Flow (LF) is for use when only purging is
required, the high flow (HF) when both purging and cooling are
required.
The optional flow alarm detects a low flow rate. This can be
linked to a warning device i.e. Klaxon or annunciator lamp to
alarm once the flow falls below the required rate.
4 Holes
Ø0.31
Note: Replacement filters and other spares are available from Land
Infrared.
15
For more than fifty years LAND have supplied temperature measuring systems and instruments
to many different industries all over the world. Now the world leader in non contact thermometry,
our expert advice and support is never far away.
WORLD LEADERS
WORLDWIDE SUPPORT
LAND is the world leader in the
manufacture of non contact
temperature measurement
systems, thermal imagers and
linescanners.
WORLDWIDE
SUPPORT
In addition to the companies
established in Europe, USA,
Mexico and Japan, LAND is
represented by distributors in
most of the major industrial
countries throughout the world.
Our customers benefit, on a
global basis, from practical and
expert advice from fully trained
technicians who are aware of
specific requirements for their
country and industry.
Expert advice and support is never far away
CALIBRATION
APPLICATIONS
LAND have solved many different temperature measurement problems in a wide variety of industries
from food to atomic energy, some of which are list below:
•
•
•
•
•
Iron & Steel
Petrochemical
Heat Treatment
Minerals
Glass
•
•
•
•
•
Maintenance
Power & Utilities
Aerospace
Electronics
Pharmaceuticals
•
•
•
•
•
Plastics
Paper
Rubber
Textiles
Non-ferrous Metals
For further information or free advice on specific temperature measurement problems within these or
any other industry, contact your nearest Land office.
PRODUCT ASSURANCE
When you specify LAND products you are assured of receiving a completely pretested, calibrated
working product. Each instrument is carefully checked to ensure complete compliance with specification
and is fully guaranteed. LAND was the first manufacturer of infrared instruments to successfully obtain
ISO 9001 Quality Management System Approval for both design and manufacture of non contact
infrared temperature measuring equipment.
A
LAND operate an extensive
calibration
service.
All
calibrations made are traceable
to
National
Standards.
Calibration certificates are
available from our UKAS
accredited calibration laboratory
0034.
In the USA a traceable
calibration certificate can be
issued complying with the
National Institute of Standards
and Technology (NIST).
A consultancy service is also
available for those companies
who wish to establish their own
in-house calibration facility.
These products comply with current European directives relating to electromagnetic compatibility
and safety (EMC directive 89/336/EEC; Low voltage directive 73/23/EEC).
The Quality Management System of Land Instruments International Ltd. Is approved to BS EN ISO9001:2000
for the design and manufacture, stockholding, in-house repair and site servicing of non contact temperature
measuring instrumentation. Associated software designed and developed in accordance with TickIT.
Calibration certificates are available from our UKAS accredited Calibration Laboratory No. 0034. The Land
calibration laboratory complies with the requirements of the international standard BS EN/IEC 17025.
abc abcdefg
abc
Land Instruments International • Dronfield S18 1DJ • England • Tel: (01246) 417691 • Fax: (01246) 410585
Email: infrared.sales@landinst.com • Internet: www.landinst.com
instruments international
France
Land Instruments Sarl
Tel: (1) 34 62 05 45 • Fax: (1) 30 56 51 12
Email: commercial@landinst.fr
Germany
Land Instruments GmbH
Tel: 02171/7673-0 • Fax: 02171/7673-9
Email: infrarot@landinst.de
Italy
Land Instruments Srl
Tel: 02/99040423 • Fax: 02/99040418
Email: infrared@landinst.it
Japan
Land KK
Tel: 06 6330 5153 • Fax: 06 6330 5338
Email: ikeland@silver.ocn.ne.jp
Spain
Land Instruments International
Tel: 91 630 0791 • Fax: 91 630 2918
Email: land-infrared@landinst.es
Mexico
Land Instruments International
Tel: 52 55 9171 1466 • Fax: 52 55 9171 1477
Email: ventas@landinstruments.net
Infrared Temperature Measurement
Printed in England
Land Instruments International • 10 Friends Lane • Newtown, PA 18940-1804 • U.S.A. • Tel: (215) 504-8000
Fax: (215) 504-0879 • Email: irsales@landinstruments.net • Internet: www.landinstruments.net
Continuous product development may make it necessary to change these details without notice.
S4M100E-US/0503