JB Systems THE WINNER THE ROVER Users Guide

JB Systems THE WINNER THE ROVER Users Guide
JB Systems
THE WINNER
THE ROVER
Users Guide
Please read these instructions carefully before use
E.
FIXTURE CLEANING
The cleaning of internal and external optical lenses and/or mirrors must be
carried out periodically to optimize light output. Cleaning frequency depends on the
environment in which the fixture operates: damp, smoky or particularly dirty
surroundings can cause greater accumulation of dirt on the unit’s optics.
•
•
•
INDEX
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
Clean the external optics at least once every 20 days. Clean the internal optics
A. GENERAL INSTRUCTIONS
at least every 30/60 days.
B. MAIN FEATURES
C. LAMP
D. HOW TO CONTROL THE UNIT
-----(1) By universal DMX controller
-----(2) Preprogrammed function
-----(3) By easy controller
Technical Specifications
Power
120V~60Hz AC
230V~50Hz AC
Fuse
20mm Glass 6.3A Fast Blow 20mm Glass 5A Fast Blow
Lamps
1 x 24V 250W
Part No. ELC 24V 250W
Dimension 500mm x 200mm x 155mm / 19.69in x 7.87in x 6.1in
Weight
10 kg / 22 lbs
=================================================================
For further requirements, contact the nearest authorized technical assistance office
=================================================================
E. FIXTURE CLEANING
(2)Preprogram functions
The unit can be linked together as master/slave in daisy chain in linkage as
many units as required and run by built in preprogrammed chase sequences
automatically or by sound activation.
Not need to set the dipswitches in master/slave mode.
* 2-light show
Dipswitch 10 “off” means the unit works normally and “on” means inversion. In
order to creating a great light show, you can set dip switch 10 “on” on any unit that is
linking to the master unit to get contrast movement to each other, even if you have
two units only. Dipswitch 10 on the first unit is no use in the DMX linking, as it is the
master unit that operates the light show.
(3)By easy controller
The easy remote control is used only in master/slave
mode. By connecting to the 1/4” microphone jack of the
first unit (its DMX input plug is not used), you will find that
the remote control on the first unit will control all the other
units for stand by, shutter and slow/fast function.
Shutter function is only effective while the button is
held down. It has three modes.
1. The first press:synchronous strobe.
2. The second press:two-light show strobe.
3. The third press:gobos and colors strobe at random.
DMX512 CONFIGURATION
CHANNEL 1
SHUTTER
255
CHANNEL 2
GOBO
255
Fast
255
CHANNEL 3
COLOR
CHANNEL 4
PAN
FLAT
BARREL
CHANNEL 5
TILT
FLAT
BARREL
Stopped
Fast
A.
GENERAL INSTRUCTIONS
Please read the enclosed instructions carefully as they include important points
about safety for the installation, usage and maintenance of the unit.
• Please keep this booklet with the unit for future consultation. If you sell the unit to
another user, be sure that the new user also receives this instruction booklet thus
Gobo
174
giving them the necessary information about the use and general warnings
Slow
Color
92
10
0
Gobo+Color
Stopped
128
120
112
104
96
88
80
72
64
56
48
40
32
24
16
8
0
Slow
Gobo 14
Gobo 13
Gobo 12
Gobo 11
Gobo 10
Gobo 9
Gobo 8
Gobo 7
Gobo 6
Gobo 5
Gobo 4
Gobo 3
Gobo 2
Gobo 1
Open
Blackout
128
121
110
99
88
77
66
55
44
33
22
11
0
regarding the unit.
Stopped
Green
Pink
case any damage may have occurred during shipping.
Light blue
• Locate a suitable spot for your device where there is good ventilation. Also, make
Amber
Red
sure that no ventilating fans or slots are blocked.
Purple
Orange
• Protect our environment! Please dispose of the packing boxes properly.
Light green
Blue
• The electrical work that is necessary for installation must done by qualified
Yellow
Magenta
White
Stopped
personnel.
• Always remember to unplug the unit from the main power before any service is
GOBOS
1
• Before the initial start-up, please unpack and carefully check all components in
2
3
4
5
6
7
8
9
10
11
12
13
14
done. Do not open the unit. There are no serviceable parts inside.
• It is very important to ground the yellow/green conductor to earth in order to meet
• Start the address
regulations for safety.
How to address your DMX512 system:
• Check the surrounding area and make sure there are no flammable liquids, water or
1. Select the channels of DMX controller
metal objects that could enter the fixture. If a foreign object enters the unit,
2. Dipswitches
immediately disconnect the main power. Also, place the fixture in a well-ventilated
Dip
#1
#2
#3
#4
#5
#6
#7
#8
#9
Value
1
2
4
8
16
32
64
128
256
• Examples:
room at about 15 cm from the walls.
• Do not touch any wires during operation, as high voltage is hazardous.
• In the event of serious operating problems, stop using the unit immediately. Never
Channel 01:dip / on : #1(=1)
try to repair the unit yourself. Repairs carried out by unqualified personnel can lead
Channel 06:dip / on : #2, #3(2+4=6)
to damage or malfunction. Please contact the nearest authorized Technical
Channel 11:dip / on : #1, #2,#4(1+2+8=11)
Assistance Center. Always use genuine spare parts.
Channel 16:dip / on : #5(=16)
B.
MAIN FEATURES
• Voltage:AC 120V~60Hz or 230V~50 Hz
• Bulb: ELC 24V 250W
• The unit is a DMX512 scanner. It features full DMX512 control, 14 gobos plus
open and 11 colors plus white, accurate focusable optics system and stepper
D.
HOW TO CONTROL THE UNIT
(1)By universal DMX controller
The DMX512 is widely used in intelligent lighting control, with a maximum of 512
channels.
1
2
3
4
motor with blackout feature. Fan cooled.
• It can be operated by DMX512 control or can be used as an individual unit without
a control.
• It can be linked together in master/slave combination units, as many as required in
DMX512
4 channels and run by built-in preprogrammed chase sequences automatically or
by sound activation through an internal microphone to create an intelligent effect.
• Please use a 3 pin XLR cable/plug when connecting them together.
• It features different preprogrammed chase patterns.
• Dimensions:500mm x 200mm x 155 mm / 19.69 in x 7.87 in x 6.1 in
• Weight:10 kg / 22 lbs
1
DMX INPUT
3
2
120 ohm 1/4W
COMMON
DMX +
DMX -
1
3
2
Termination reduces signal errors and to avoid signal
transmission problems and interference. It is always
advisable to connect a DMX terminal.
(Resistance 120 ohm 1/4W) between pin2 (DMX-) and
pin3 (DMX+) of the last fixture.
DMX OUTPUT
1
3
2
y A DMX512 system requires a controller, lighting equipment and cable. These are
connected together in a “daisy chain” with the terminator at the end. The cable
C.
LAMP
ELC 24V 250W
• Always switch off the mains supply and never handle the lamp or luminaire when it
is hot.
• Do not touch the bulb with bare hands. If this does happen, clean the lamp with
denatured alcohol and wipe with a lint free cloth before installing.
cannot be branched or split to a “Y” cable.
y The terminator requires a 90-120 Ohm 1/4 Watt resistor soldered between two
signal cables.
y The DMX512 uses a very high-speed signal. Inadequate or damaged cables, bad
solder joints or corroded connectors can easily distort the signal and shut down
the system. A reliable DMX512 system starts with good quality cables.
y Each lighting unit needs to have an address set to receive the data sent by the
controller. The address number is between 0-511. The end of the DMX512
system should be terminated reducing signal errors.
y 3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising