ELECTRIC AIR CONDITIONER Model PA12

ELECTRIC AIR CONDITIONER Model PA12
AVAILABLE SIZES:
Nominal sizes are available from
018 through 060 to meet the
needs of residential and light
commercial applications.
CERTIFICATION:
All models are listed with UL,
(U.S. and Canada), ARI, and CEC.
UNIT DESIGN:
The copper tube, enhanced sine
wave, aluminum fin coil is designed for optimum heat transfer.
Vertical air discharge carries
sound and hot condenser air up
and away from adjacent patio
areas and foliage. The base pan
is designed for easy removal of
water, dirt, and leaves.
COMPRESSOR:
Each compressor is protected
with internal temperature- and
current-sensitive overloads. An
internal pressure relief valve provides high-pressure protection to
the refrigerant system. For
improved serviceability, all models are equipped with a compressor terminal plug.
SERVICE VALVES:
Both service valves are brass,
front seating type with sweat connections. Valves are externally
located so refrigerant tube connections can be made quickly and
easily. Each valve has a service
port for ease of checking operating refrigerant pressures.
SERVICEABILITY:
One access panel provides
access to electrical controls.
Removal of top gives access to
fan motor, compressor, and condenser coil.
ELECTRICAL RANGE: Units are offered in 208-230v, single phase.
FAN MOTOR:
The totally enclosed fan motor
provides greater reliability under
adverse conditions and dependable performance for many years.
The permanent split capacitor
type motor was designed for optimum efficiency. The motor was
then qualified under extreme conditions to help ensure a long, reliable life.
CABINET:
A weather protective cabinet of
steel is protected with a galvanized coating and treated with a
layer of zinc phosphate. A coat of
modified polyester powder coating is then applied and baked on,
providing each unit with a hard,
smooth finish that will last for
many years. All screws on cabinet exterior are coated for a longlasting, rust-resistant, quality
appearance.
ELECTRIC AIR CONDITIONER
Model PA12
FEATURES
SS-PA12-04
NOTES:
1.Allow 30 in. clearance to service side of unit, 48 in.
above unit, 6 in. on one side, 12 in. on remaining side,
and 24 in. between units for proper airflow.
2.Minimum outdoor operating ambient in cooling mode is 55°F
max 125°F.
3.Series designation is the 14th position of the unit
model number.
4.Center of gravity .
A
AIR IN
AIR
DISCHARGE
AIR
DISCHARGE
AIR
DISCHARGE
FIELD POWER
SUPPLY CONN
7/8 IN. DIA HOLE WITH
1 1/8 IN. DIA KNOCKOUT
AND 1 3/8 IN. DIA KNOCKOUT
3/8 IN. DIA
TIEDOWN
KNOCKOUTS
(2) PLACES
AIR IN
FIELD CONTROL
SUPPLY CONN
7/8 IN. DIA HOLE
AIR IN
3/8 IN. DIA LIQUID
LINE CONN
N
J
AIR
DISCHARGE
B
P
C
2 7/8″
AIR IN
D DIA VAPOR LINE CONN
M
1 1/4″
F
E
A96237
DIMENSIONS (IN.)
SHIPPING
WEIGHT
(Lb)
SERIES
A
B
C
D
E
F
J
M
N
P
018
A
22-1/2
31-15/16
3-3/16
5/8
18-1/2
4-1/16
8-3/16
12-1/8
12-1/4
11
143
024
A, B, C
30
23-15/16
3-3/16
5/8
23-1/2
6-1/2
10
14-3/4
14
11
152
030
A, B
30
27-15/16
3-3/16
3/4
23-1/2
6-1/2
10
14-3/4
14
11
164
036
A, B
30
27-15/16
3-3/16
3/4
23-1/2
6-1/2
10
14-3/4
14
11
169
042
A, B
30
33-15/16
3-1/4
7/8
23-1/2
6-1/2
10
14-3/4
14
15
183
048
B, C
30
39-15/16
3-1/4
7/8
23-1/2
6-1/2
10
14-3/4
14
15
183
048
D
30
33-15/16
3-1/4
7/8
23-1/2
6-1/2
10
15-1/2
14-3/4
15
253
060
A, B
30
39-15/16
3-1/4
7/8
23-1/2
6-1/2
10
15-1/2
14-3/4
15
267
A
AIR
CO
Y
NING
ITIO
ND
UNIT
AR
T
IFIED O ARI A
RT
S
C
CE
EQ
RI
YING WITH
PL
OM
MANUFACTUR
ER
UNIT
SIZE
UIP M E NT
STA
NDARD
21
0
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI.
—2—
REGISTERED QUALITY SYSTEM.
SPECIFICATIONS
UNIT SIZE
SERIES
ELECTRICAL
Unit Volts—Hertz—Phase
Operating Voltage Range*
Compressor—Rated Load Amps
Locked Rotor Amps
Condenser Fan Motor—Full Load Amps
Min Unit Ampacity for Wire Sizing
Min Wire Size (60°/75° Copper) AWG**
Max Wire Length (60°/75°) (Ft)‡
Max Branch Circuit Fuse Size†
COMPRESSOR AND REFRIGERANT
Compressor—Manufacturer
Type
Temperature and Current Protection
Refrigerant—Type and Amount (Lb) @ 15 ft
Refrigerant Tubes (In. OD)
Vapor and Liquid (Up to 50 Ft)
CONDENSER COIL AND FAN
Coil Face Area (Sq Ft)
Fan Motor—HP, Type, and RPM
Volts—Hertz—Phase
Condenser Airflow (CFM)
OPTIONAL EQUIPMENT
Cycle Protector
Start Assist—PTC Type
Start Assist—Capacitor/Relay Type
MotorMaster® Control
Ball Bearing Fan Motor
Low-Pressure Switch
High-Pressure Switch
Sound Hood
Time-Delay Relay
Low-Ambient Kit
Winter Start Control
Evaporator Freeze Thermostat
Crankcase Heater
Liquid Line Solenoid Valve††
Coastal Filter
Filter Drier
TXV Kit (RPB)
TXV (Hard Shutoff)††
Standard Thermostat, Manual Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Thermostat, Auto Changeover,
7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Outdoor Sensor
Backplate for Standard Thermostat
Backplate for Programmable Thermostat
018
024
030
036
A
A, B/C
A, B
A, B
15.0
72.5
0.8
19.6
14/14
39/37
30
17.9
88.0
1.1
23.5
12/12
52/50
30
208-230—60—1
187—253
9.0
41.0
0.5
11.8
14/14
66/62
20
11.4/10.9
56.0/54.0
0.5
14.8/14.2
14/14
53/50
25
Copeland
Scroll
Internal Line Break
R-22 5.25
R-22 6.00
R-22 4.75
5/8 and 3/8
R-22 6.25
3/4 and 3/8
10.17
1/12 PSC and 1100
10.71
1700
2000
12.85
1/15 PSC and 825
208/230—60—1
3000
KSACY0101AAA
KAACS0201PTC
KSAHS1501AAA
32LT660004
N/A
KAACF1001MED
KAATX0201RPB
HC38GE231
KAALP0101LPS
KSAHI0101HPS
KSASH1801COP
KSASH1901CYL
KAATD0101TDR
KSALA0210R22
KAAWS0101AAA
KAAFT0101AAA
KAACH1201AAA
KAALS0101LLS
KAACF1101LRG
P502-8083S
KAATX0301RPB
KAATX0401RPB
KAATX0501RPB
KSATX0601HSO
TSTATPPBAC01
TSTATPPPAC01
TSTATXXSEN01-B
TSTATXXBBP01
TSTATXXPBP01
See notes on page 4.
—3—
SPECIFICATIONS Continued
UNIT SIZE
042
048
060
SERIES
ELECTRICAL
A, B
B, C/D
A, B
20.0
104.0
1.1
26.1
10/10
74/70
40
208-230—60—1
187—253
20.2/19.7
129.0/137.0
1.1
26.4/25.7
10/10
74/70
40
28.8
148.0
1.4
37.4
8/8
82/78
50
R-22 6.50
Copeland
Scroll
Internal Line Break
R-22 9.75/8.75
R-22 11.50
Unit Volts—Hertz—Phase
Operating Voltage Range*
Compressor—Rated Load Amps
Locked Rotor Amps
Condenser Fan Motor—Full Load Amps
Min Unit Ampacity for Wire Sizing
Min Wire Size (60°/75° Copper) AWG**
Max Wire Length (60°/75°) (Ft)‡
Max Branch Circuit Fuse Size†
COMPRESSOR AND REFRIGERANT
Compressor—Manufacturer
Type
Temperature and Current Protection
Refrigerant—Type and Amount (Lb) @ 15 ft
Refrigerant Tubes (In. OD)
Vapor and Liquid (Up to 50 Ft)
CONDENSER COIL AND FAN
Coil Face Area (Sq Ft)
Fan Motor—HP, Type, and RPM
Volts—Hertz—Phase
Condenser Airflow (CFM)
OPTIONAL EQUIPMENT
Cycle Protector
Start Assist—PTC Type
Start Assist—Capacitor/Relay Type
MotorMaster® Control
Ball Bearing Fan Motor
Low-Pressure Switch
High-Pressure Switch
Sound Hood
Time-Delay Relay
Low-Ambient Kit
Winter Start Control
Evaporator Freeze Thermostat
Crankcase Heater
Liquid Line Solenoid Valve††
Coastal Filter
Filter Drier
TXV Kit (RPB)
TXV (Hard Shutoff)††
Standard Thermostat, Manual Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Thermostat, Auto Changeover,
7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Outdoor Sensor
Backplate for Standard Thermostat
Backplate for Programmable Thermostat
7/8 and 3/8
16.1
19.3/16.1
1/5 PSC and 825
19.3
1/4 PSC and 1125
208/230—60—1
3000
3400
KSACY0101AAA
KAACS0201PTC
KSAHS1501AAA
32LT660004
HC38GE231
KSASH1901CYL
KAATX0501RPB
KSATX0601HSO
HC40GE232
KAALP0101LPS
KSAHI0101HPS
KSASH2101COP/KSASH0601COP
KSASH2101COP
KAATD0101TDR
KSALA0201R22
KAAWS0101AAA
KAAFT0101AAA
KAACH1201AAA
KAALS0101LLS
KAACF1101LRG
P502-8163S
KAATX0601RPB
KAATX0701RPB
KSATX0701HSO
TSTATPPBAC01
TSTATPPPAC01
TSTATXXSEN01-B
TSTATXXBBP01
TSTATXXPBP01
N/A—Not applicable in this application.
* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† Time-delay fuse or circuit breaker.
‡ Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.
** If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70)
Article 336-26.
†† Do not use hard shutoff TXV with liquid solenoid valve.
NOTES: 1. Control circuit is 24v on all units and requires external power source.
2. All motors/compressors contain internal overload protection.
3. Copper wire must be used from service disconnect to unit.
—4—
OPTIONAL EQUIPMENT USAGE GUIDELINE
ACCESSORY
REQUIRED FOR
LOW-AMBIENT
APPLICATIONS
(Below 55°F)
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 50 Ft)
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 Miles)
Crankcase Heater
Yes
Yes
No
Evaporator Freeze Thermostat
Yes
No
No
Winter Start Control
Yes†
No
No
Accumulator
No
No
No
Compressor Start Assist
Capacitor and Relay
Yes
Yes
No
MotorMaster® Control
Yes
No
No
Wind Baffle
See Low-Ambient Instructions
No
No
Coastal Filter
No
No
Yes
Support Feet
Recommended
No
Recommended
Liquid-Line Solenoid Valve
or
Hard Shutoff TXV
No
See Long-Line
Application
Guideline
No
Ball Bearing Fan Motor
Yes
No
No
* For tubing line sets between 50 and 175 ft and/or 20 ft vertical differential, refer to Residential Split Systems Long-Line Application Guidelines.
† Only when low-pressure switch is used.
OPTIONAL EQUIPMENT DESCRIPTION AND USAGE (Listed Alphabetically)
1. Ball Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
SUGGESTED USE: Required on all units where Low-Ambient kit (full modulation feature) or MotorMaster® Control has been added.
2. Coastal Filter
A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow.
SUGGESTED USE: In geographic areas where salt damage could occur.
3. Compressor Start Assist—Capacitor/Relay Type
Start capacitor and start relay gives hard boost to compressor motor at each start-up.
SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft.
Installations where outdoor design temperature exceeds 105°F (40.6°C).
Replacement installations with hard shutoff expansion valve on indoor coil.
4. Compressor Start Assist—PTC Type
Solid-state electrical device which gives a soft boost to the compressor at each start-up.
SUGGESTED USE: Installations with marginal power supply.
Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil.
5. Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication
on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control.
SUGGESTED USE: When interconnecting tube length exceeds 50 ft.
When unit will be operated below 55°F (12.8°C) outdoor air temperature. (Use with low-ambient controller.)
All commercial installations.
6. Evaporator Freeze Thermostat
An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions.
SUGGESTED USE: All units where winter start control has been added.
7. High-Pressure Switch
Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to about 400
psig. Provides additional protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling, cycle protector can
be used with this switch.
SUGGESTED USE: Installations exposed to very ‘‘dirty’’ outdoor air.
Installations where condenser inlet air temperature exceeds 125°F (51.7°C).
8. Liquid Solenoid Valve (LSV)
An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant
liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle.
NOTE: Compressor start assist—capacitor/relay type—must also be used on units with reciprocating compressors.
SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
In certain long line applications. Refer to Residential Split System Long-Line Application Guidelines.
9. Low-Pressure Switch
Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27
psig. Prevents indoor coil freeze-up due to loss of indoor airflow. Also, provides additional protection against compressor damage due to loss of refrigerant
charge. To prevent rapid compressor recycling, cycle protector can be used with this switch.
SUGGESTED USE: Where indoor coil is exposed to ‘‘dirty’’ air.
All commercial installations.
10. MotorMaster® Control
A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing
temperature during operation in cooling mode only. For outdoor temperatures down to –20°F, it maintains condensing temperature at 100°F ± 10°F.
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F.
All commercial installations.
—5—
OPTIONAL EQUIPMENT DESCRIPTION AND USAGE (Listed Alphabetically) Continued
11. Sound Hood
Wraparound sound attenuation cover for the compressor. Reduces unit sound level by about 2 dBA.
SUGGESTED USE: Unit installed closer than 15 ft to quiet areas—bedrooms, etc.
Unit installed between 2 houses less than 10 ft apart.
12. Thermostatic Expansion Valve (TXV) Kits
A modulating flow control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the
evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shut-off and RPB type valves are available.
SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
13. Time-Delay Relay
An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off.
SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
14. Winter Start Control
An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load conditions.
SUGGESTED USE: All air conditioners where low-ambient controller has been added.
METERING DEVICE
PISTON*
IDENTIFICATION NO.
UNIT SIZE-SERIES
018-A
52
024-A, B
61
024-C
59
030-A, B
70
036-A, B
76
042-A, B
82
048-B, C, D
90
060-A, B
101
* Piston listed is for any approved coil non-capillary tube combination. Piston is
shipped with outdoor unit and must be installed in an approved indoor coil.
SOUND POWER (dBA)
OCTAVE BAND CENTER FREQUENCY (HZ)
UNIT
SIZE
Sound Level
(dBA)
125
250
500
1000
2000
4000
8000
018-A
76
53.9
60.0
66.6
72.0
65.4
61.0
55.2
024-A, B
78
49.0
59.5
67.0
79.0
68.5
65.5
57.0
024-C
78
50.7
60.8
68.2
73.3
62.9
57.6
54.2
030-A, B
78
51.5
61.5
68.0
73.0
66.5
63.5
59.0
036-A, B
80
49.0
60.5
64.5
74.5
74.5
67.0
57.5
042-A, B
80
48.5
61.0
64.5
69.5
69.0
70.0
64.5
048-B, C
80
50.0
65.5
75.5
76.0
70.0
66.0
57.5
048-D
80
57.1
65.3
69.7
76.2
70.2
68.4
62.5
060-A, B
80
54.5
64.0
70.5
71.0
68.0
67.5
60.0
—6—
RATINGS AND PERFORMANCE
UNIT
SIZE-SERIES
018-A
024-A, B, C
030-A, B
036-A, B
042-A, B
INDOOR
MODEL
COOLING
CAPACITY
FACTORY
SUPPLIED
ENHANCEMENT
*CC5A/CD5AA018
CC5A/CD5AA024
CC5A/CD5AW024
CE3AA024
CF5AA024
CK3BA024
CK5A/CK5BA018
CK5A/CK5BA024
CK5A/CK5BW024
FF1DNA018
FF1DNA024
FF1DNE018
FF1DNE024
PF1MNB018
PF1MNB024
*CC5A/CD5AA024
CC5A/CD5AA030
CC5A/CD5AW024
CC5A/CD5AW030
CE3AA024
CE3AA030
CF5AA024
CK3BA024
CK3BA030
CK5A/CK5BA024
CK5A/CK5BA030
CK5A/CK5BW024
CK5A/CK5BW030
FF1DNA024
FF1DNA030
FF1DNE024
FF1DNE030
PF1MNB024
PF1MNB030
CC5A/CD5AA030*
CC5A/CD5AA036
CC5A/CD5AW030
CE3AA030
CE3AA036
CK3BA030
CK3BA036
CK5A/CK5BA030
CK5A/CK5BA036
CK5A/CK5BW030
CK5A/CK5BW036
FF1DNA030
PF1MNA030
PF1MNA036
CC5A/CD5AA036*
CC5A/CD5AA042
CC5A/CD5AW042
CE3AA036
CE3AA042
CK3BA036
CK3BA042
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BN036
CK5A/CK5BW036
PF1MNA036
PF1MNA042
CC5A/CD5AA042*
CC5A/CD5AC048
CC5A/CD5AW042
CC5A/CD5AW048
CE3AA042
CE3AA048
CK3BA042
CK3BA048
CK5A/CK5BA042
CK5A/CK5BA048
CK5A/CK5BN048
CK5A/CK5BW048
PF1MNA042
PF1MNA048
17,000
17,600
17,600
17,600
17,600
17,600
17,000
17,600
17,600
17,000
17,000
17,000
17,000
17,000
17,600
23,000
23,200
23,000
23,200
23,400
23,600
23,000
23,000
23,400
23,000
23,400
23,000
23,400
23,200
23,400
23,200
23,400
23,200
23,600
29,000
29,000
28,000
29,000
29,600
29,000
29,600
29,000
29,600
29,000
29,600
29,000
29,200
29,600
35,000
33,800
33,400
34,800
35,000
35,000
35,000
35,000
35,000
33,000
35,000
34,800
35,000
40,000
40,000
40,000
40,500
40,000
40,000
40,000
40,500
40,000
40,500
39,500
40,500
40,000
40,500
None
None
None
None
None
None
None
None
None
TDR
TDR
TDR&TXV
TDR&TXV
TDR
TDR
None
None
None
None
None
None
None
None
None
None
None
None
None
TDR
TDR
TDR&TXV
TDR&TXV
TDR
TDR
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
TDR
TDR
TDR
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
TDR
TDR
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
TDR
TDR
See notes on page 8.
—7—
SEER
Payne GAS FURNACE ACCESSORY
STANDARD
OR ACCESSORY
RATING
TDR†
TXV‡
LLS
—
—
—
—
—
—
—
—
—
12.00
12.00
12.00
12.00
12.00
12.50
—
—
—
—
—
—
—
—
—
—
—
—
—
12.00
12.00
12.00
12.00
12.00
12.00
—
—
—
—
—
—
—
—
—
—
—
12.00
12.10
12.00
—
—
—
—
—
—
—
—
—
—
—
11.50
12.00
—
—
—
—
—
—
—
—
—
—
—
—
11.80
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
—
—
—
—
—
—
12.00
12.10
12.00
12.10
12.00
12.10
12.00
12.00
12.10
12.00
12.10
12.00
12.10
—
—
—
—
—
—
12.00
12.20
12.20
12.00
12.20
12.00
12.20
12.00
12.20
12.00
12.20
—
—
—
12.00
12.00
12.00
11.80
12.10
12.00
12.00
12.00
12.00
11.70
12.00
—
—
12.00
11.80
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
—
—
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
—
—
12.00
12.50
12.00
12.10
12.00
12.10
12.00
12.10
12.00
12.00
12.10
12.00
12.10
12.00
12.10
12.00
12.00
—
—
12.00
12.00
12.00
12.20
12.20
12.00
12.20
12.00
12.20
12.00
12.20
12.00
12.20
12.00
12.10
12.00
12.00
12.00
12.00
11.80
12.10
12.00
12.00
12.00
12.00
11.70
12.00
11.50
12.00
12.00
11.80
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
11.80
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
—
—
—
—
—
—
12.00
12.10
12.00
12.10
12.00
12.10
12.00
12.00
12.10
12.00
12.10
12.00
12.10
—
—
—
—
—
—
12.00
12.20
12.20
12.00
12.20
12.00
12.20
12.00
12.20
12.00
12.20
—
—
—
12.00
12.00
12.00
11.80
12.10
12.00
12.00
12.00
12.00
11.70
12.00
—
—
12.00
11.80
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
—
—
EER
10.90
11.05
11.05
11.10
11.05
11.25
11.05
11.25
11.25
11.35
11.20
11.35
11.35
11.00
11.35
10.75
10.75
10.75
10.75
10.80
10.90
10.70
10.80
10.80
10.90
10.85
10.90
10.80
10.75
10.90
10.80
10.95
11.25
11.10
10.60
10.65
10.65
10.55
10.70
10.65
11.00
10.65
11.00
10.65
11.00
10.60
10.60
10.55
10.40
10.40
10.40
10.40
10.55
10.40
10.40
10.40
10.40
10.15
10.40
10.20
10.45
10.35
10.10
10.35
10.35
10.40
10.25
10.35
10.40
10.35
10.40
10.40
10.40
10.10
10.30
RATINGS AND PERFORMANCE Continued
UNIT
SIZE-SERIES
048-B, C, D
060-A, B
INDOOR
MODEL
COOLING
CAPACITY
FACTORY
SUPPLIED
ENHANCEMENT
*CD5AA048
CC5A/CD5AA060
CC5A/CD5AC048
CC5A/CD5AW048
CC5A/CD5AW060
CE3AA048
CE3AA060
CF5AA048
CK3BA048
CK3BA060
CK5A/CK5BA048
CK5A/CK5BA060
CK5A/CK5BT048
CK5A/CK5BT060
CK5A/CK5BW048
CK5A/CK5BX060
PF1MNB048
PF1MNB060
PF1MNB070
PF1MNB071
CC5A/CD5AW060*
CC5A/CD5AA060
CE3AA060
CK3BA060
CK5A/CK5BA060
CK5A/CK5BX060
PF1MNA060
PF1MNA070
PF1MNA071
47,000
47,500
46,500
47,000
48,000
47,000
47,500
47,000
47,000
47,500
47,000
47,500
47,000
47,500
47,000
48,000
47,000
47,500
48,000
48,000
57,000
55,000
57,000
55,000
55,000
57,000
57,000
58,000
58,000
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
TDR
TDR
TDR
TDR&TXV
NONE
NONE
NONE
NONE
NONE
NONE
TDR
TDR
TDR & TXV
SEER
STANDARD
RATING
Payne GAS
FURNACE OR
ACCESSORY TDR†
ACCESSORY
TXV‡
LLS
EER
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
12.00
12.10
12.50
13.00
—
—
—
—
—
—
11.50
12.00
12.50
12.00
12.10
11.80
12.00
12.20
12.00
12.10
12.00
12.00
12.10
12.00
12.10
12.00
12.10
12.00
12.20
—
—
—
—
12.00
11.50
12.00
11.50
11.50
12.00
—
—
—
12.00
12.10
11.80
12.00
12.20
12.00
12.10
12.00
12.00
12.10
12.00
12.10
12.00
12.10
12.00
12.20
12.00
12.10
12.50
—
12.00
11.50
12.00
11.50
11.50
12.00
11.50
12.00
12.50
12.00
12.10
11.80
12.00
12.20
12.00
12.10
12.00
12.00
12.10
12.00
12.10
12.00
12.10
12.00
12.20
—
—
—
—
12.00
11.50
12.00
11.50
11.50
12.00
—
—
—
10.70
10.70
10.60
10.70
10.95
10.80
11.00
10.75
10.75
10.95
10.75
10.95
10.75
10.95
10.75
11.10
10.65
10.70
11.05
12.10
10.45
10.25
10.60
10.25
10.25
10.55
10.30
10.70
11.15
* Tested Combination
† In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Payne furnaces are equipped with TDR.
‡ Requires hard shutoff TXV; based on computer simulation.
EER — Energy Efficiency Ratio
SEER — Seasonal Energy Efficiency Ratio
TDR — Time-Delay Relay.
TXV — Thermostatic Expansion Valve.
NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other
combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Minimum outdoor operating ambient in cooling mode is 55°F (12.8°C), maximum 115°F (46.1°C).
—8—
DETAILED COOLING CAPACITIES*
CONDENSER ENTERING AIR TEMPERATURES °F
EVAPORATOR
AIR
75
85
Capacity
MBtuh†
CFM
EWB
Total
Total
System
Sens‡ kW**
95
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
105
115
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
15.77
13.92
12.39
12.38
16.07
14.19
12.86
12.87
16.29
14.36
13.30
13.31
8.71
10.77
12.39
12.38
9.16
11.49
12.86
12.87
9.59
12.16
13.30
13.31
PA12NA018-A Outdoor Section With CC5A/CD5AA024 Indoor Section
525
600
675
72
67
62
57
72
67
62
57
72
67
62
57
18.61
17.37
15.61
14.90
18.69
17.66
15.98
15.53
18.72
17.85
16.31
16.09
9.64
12.13
14.27
14.90
9.85
12.73
15.18
15.53
10.02
13.29
16.02
16.09
1.25
18.35
9.62
1.40
17.68
9.42
1.57
17.03
9.26
1.24
16.68
11.92
1.39
15.80
11.54
1.53
14.90
11.17
1.23
14.88
13.89
1.35
14.07
13.47
1.49
13.22
12.99
1.22
14.36
14.36
1.34
13.72
13.72
1.48
13.06
13.06
1.28
18.60
10.07
1.43
17.98
9.84
1.59
17.11
9.54
1.27
17.00
12.74
1.42
16.10
12.26
1.57
15.19
11.89
1.25
15.20
14.73
1.39
14.38
14.38
1.53
13.61
13.61
1.25
14.93
14.93
1.38
14.30
14.30
1.52
13.62
13.62
1.31
18.70
10.25
1.46
18.23
10.26
1.62
17.37
10.00
1.30
17.22
13.25
1.44
16.35
12.97
1.60
15.42
12.60
1.28
15.51
15.51
1.42
14.81
14.81
1.56
14.07
14.07
1.28
15.46
15.46
1.42
14.82
14.82
1.56
14.08
14.08
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Indoor
Section
Unit
Size
Capacity
Power
CC5A/CD5AA
018
024
024
024
024
024
018
024
1.00
1.04
1.04
1.04
1.04
1.04
1.00
1.04
1.00
1.02
1.02
1.02
1.02
1.00
0.99
1.00
CC5A/CD5AW
CE3AA
CF5AA
CK3BA
CK5A/CK5BA
1.73
1.69
1.64
1.64
1.78
1.72
1.68
1.68
1.80
1.75
1.72
1.72
1.91
1.86
1.81
1.81
1.95
1.89
1.85
1.85
1.99
1.92
1.89
1.89
Cooling
Indoor
Section
Unit
Size
Capacity
Power
CK5A/CK5BW
FF1DNA
024
018
024
018
024
018
024
—
1.04
1.00
1.00
1.00
1.00
1.00
1.04
—
1.00
0.96
0.97
0.96
0.96
0.99
1.00
—
FF1DNE
PF1MNB
PA12NA024-A, B, C Outdoor Section With CC5A/CD5AA024 Indoor Section
700
800
900
72
67
62
57
72
67
62
57
72
67
62
57
26.9
24.5
22.3
21.0
27.4
25.0
22.8
21.9
27.8
25.4
23.2
22.6
13.0
16.3
19.5
21.0
13.6
17.3
20.8
21.9
14.1
18.2
22.0
22.6
1.73
25.9
12.7
1.91
25.0
12.3
2.13
24.1
12.0
1.73
23.7
16.0
1.91
22.8
15.6
2.11
21.9
15.2
1.72
21.5
19.1
1.90
20.7
18.7
2.12
19.9
18.3
1.73
20.4
20.4
1.90
19.8
19.8
2.10
19.2
19.2
1.77
26.4
13.2
1.94
25.4
12.9
2.16
24.4
12.5
1.76
24.1
16.9
1.95
23.2
16.5
2.15
22.3
16.2
1.77
22.0
20.4
1.94
21.1
20.0
2.15
20.3
19.5
1.75
21.2
21.2
1.94
20.6
20.6
2.14
19.9
19.9
1.80
26.8
13.8
1.99
25.8
13.4
2.21
24.7
13.0
1.80
24.5
17.8
1.98
23.5
17.4
2.19
22.7
17.1
1.79
22.4
21.5
1.98
21.5
21.0
2.19
20.7
20.5
1.80
21.9
21.9
1.98
21.2
21.2
2.18
20.5
20.5
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Indoor
Section
Unit
Size
Capacity
Power
CC5A/CD5AA
024
030
024
030
024
030
024
024
030
1.00
1.01
1.00
1.01
1.02
1.03
1.00
1.00
1.02
1.00
1.01
1.00
1.01
1.01
1.01
1.00
0.99
1.01
CC5A/CD5AW
CE3AA
CF5AA
CK3BA
11.6
14.9
17.9
18.6
12.2
15.8
19.0
19.2
12.6
16.7
19.8
19.8
2.65
2.62
2.63
2.61
2.67
2.67
2.64
2.64
2.70
2.70
2.68
2.70
Cooling
Unit
Size
Capacity
Power
CK5A/CK5BA
024
030
024
030
024
030
024
030
024
030
1.00
1.02
1.00
1.02
1.01
1.02
1.01
1.02
1.01
1.03
0.99
1.01
0.99
1.01
1.01
1.00
1.00
1.00
0.96
1.00
FF1DNA
FF1DNE
PF1MNB
—9—
23.1
21.0
19.1
18.6
23.5
21.4
19.5
19.2
23.7
21.7
19.8
19.8
Indoor
Section
CK5A/CK5BW
See notes on page 12.
2.37
2.36
2.36
2.35
2.40
2.40
2.40
2.38
2.43
2.44
2.42
2.42
DETAILED COOLING CAPACITIES*
CONDENSER ENTERING AIR TEMPERATURES °F
EVAPORATOR
AIR
75
85
Capacity
MBtuh†
CFM
EWB
Total
Total
System
Sens‡ kW**
95
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
Capacity
MBtuh†
Total
System
Sens‡ kW**
Total
105
115
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
PA12NA030-A, B Outdoor Section With CC5A/CD5AA030 Indoor Section
875
1000
1125
72
67
62
57
72
67
62
57
72
67
62
57
33.4
30.5
27.8
26.2
34.1
31.1
28.4
27.2
34.6
31.6
28.9
28.1
16.2
20.3
24.3
26.2
16.9
21.4
25.8
27.2
17.5
22.6
27.2
28.1
2.17
32.3
15.8
2.38
31.2
15.3
2.60
30.0
14.9
2.15
29.5
19.8
2.35
28.5
19.4
2.58
27.4
18.9
2.13
26.8
23.8
2.34
25.9
23.3
2.56
24.9
22.8
2.12
25.4
25.4
2.33
24.7
24.7
2.54
23.9
23.9
2.22
32.9
16.5
2.42
31.7
16.0
2.65
30.5
15.6
2.20
30.1
21.0
2.40
29.0
20.6
2.64
27.8
20.1
2.18
27.4
25.3
2.39
26.4
24.8
2.61
25.3
24.2
2.17
26.4
26.4
2.38
25.6
25.6
2.60
24.8
24.8
2.27
33.4
17.1
2.46
32.2
16.6
2.70
30.9
16.2
2.24
30.6
22.1
2.45
29.4
21.6
2.67
28.2
21.2
2.23
27.9
26.7
2.43
26.8
26.1
2.66
25.8
25.4
2.22
27.3
27.3
2.43
26.4
26.4
2.65
25.5
25.5
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
2.85
2.85
2.80
2.79
2.91
2.88
2.86
2.84
2.96
2.92
2.91
2.89
28.8
26.2
23.8
23.1
29.3
26.7
24.3
24.0
29.6
27.0
24.7
24.7
14.4
18.5
22.2
23.1
15.1
19.6
23.6
24.0
15.7
20.7
24.7
24.7
3.14
3.12
3.08
3.09
3.20
3.16
3.13
3.14
3.25
3.23
3.19
3.19
Cooling
Indoor
Section
Unit
Size
Capacity
Power
Indoor
Section
Unit
Size
Capacity
CC5A/CD5AA
030
1.00
1.00
CK5A/CK5BW
030
1.00
1.00
CE3AA
030
1.00
1.01
036
1.02
1.00
036
1.02
1.01
FF1DNA
030
1.00
1.01
CK3BA
030
036
1.00
1.02
1.00
1.00
PF1MNA
030
036
1.01
1.02
1.00
1.03
CK5A/CK5BA
030
036
1.00
1.02
1.00
1.00
—
—
—
Power
PA12NA036-A, B Outdoor Section With CC5A/CD5AA036 Indoor Section
1050
1200
1350
72
67
62
57
72
67
62
57
72
67
62
57
40.4
37.2
34.0
32.4
41.2
37.8
34.7
33.6
41.7
38.3
35.2
34.7
19.9
25.1
30.2
32.4
20.8
26.7
32.2
33.6
21.6
28.1
34.0
34.7
2.73
39.1
19.4
3.02
37.6
18.8
3.31
36.1
18.2
2.72
35.8
24.6
2.98
34.5
24.0
3.27
33.1
23.5
2.69
32.8
29.6
2.96
31.5
29.0
3.27
30.2
28.3
2.67
31.4
31.4
2.94
30.5
30.5
3.25
29.4
29.4
2.81
39.8
20.2
3.07
38.2
19.7
3.37
36.5
19.1
2.77
36.5
26.1
3.04
35.0
25.5
3.33
33.6
24.9
2.75
33.4
31.6
3.01
32.2
30.9
3.32
30.8
30.1
2.74
32.7
32.7
3.01
31.6
31.6
3.32
30.5
30.5
2.86
40.2
21.0
3.13
38.6
20.5
3.43
37.1
19.9
2.83
37.0
27.5
3.10
35.5
27.0
3.41
34.0
26.4
2.81
34.0
33.3
3.07
32.7
32.4
3.37
31.4
31.4
2.80
33.7
33.7
3.08
32.5
32.5
3.37
31.3
31.3
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Indoor
Section
Unit
Size
Capacity
Power
CC5A/CD5AA
CE3AA
036
036
042
1.00
0.99
1.00
1.00
1.00
0.99
CK3BA
036
042
1.00
1.00
1.00
1.00
—10—
34.4
31.5
28.8
28.2
35.0
32.0
29.4
29.2
35.3
32.3
30.1
30.1
17.6
22.8
27.6
28.2
18.5
24.3
29.2
29.2
19.3
25.7
30.1
30.1
4.00
3.98
3.93
3.93
4.09
4.04
4.02
3.99
4.14
4.09
4.07
4.09
Cooling
Indoor
Section
Unit
Size
Capacity
Power
CK5A/CK5BA
CK5A/CK5BN
036
036
036
1.00
0.94
1.00
1.00
1.00
1.00
036
042
0.99
1.00
1.00
0.99
CK5A/CK5BW
PF1MNA
See notes on page 12.
3.64
3.63
3.58
3.59
3.70
3.68
3.63
3.64
3.78
3.74
3.72
3.70
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAPORATOR
AIR
75
85
Capacity
MBtuh†
CFM
EWB
Total
Total
System
Sens‡ kW**
95
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
105
115
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
PA12NA042-A, B Outdoor Section With CC5A/CD5AA042 Indoor Section
1225
1400
1575
72
67
62
57
72
67
62
57
72
67
62
57
46.4
42.5
38.9
37.0
47.2
43.4
39.7
38.4
47.8
44.0
40.3
39.6
22.7
28.7
34.4
37.0
23.7
30.4
36.7
38.4
24.6
32.0
38.7
39.6
3.13
44.6
22.1
3.44
42.9
21.4
3.79
41.1
20.8
3.09
41.0
28.0
3.41
39.3
27.3
3.73
37.7
26.6
3.05
37.5
33.7
3.36
35.9
32.9
3.68
34.4
32.2
3.03
35.9
35.9
3.34
34.6
34.6
3.66
33.4
33.4
3.21
45.4
23.0
3.51
43.6
22.4
3.86
41.8
21.7
3.16
41.7
29.7
3.46
40.0
29.0
3.81
38.3
28.3
3.12
38.2
35.9
3.44
36.6
35.1
3.76
35.1
34.2
3.10
37.2
37.2
3.42
35.9
35.9
3.75
34.6
34.6
3.28
46.0
23.9
3.59
44.1
23.3
3.94
42.3
22.6
3.23
42.2
31.3
3.53
40.5
30.6
3.88
38.7
29.9
3.19
38.9
37.8
3.51
37.3
36.8
3.84
35.7
35.7
3.18
38.4
38.4
3.50
37.0
37.0
3.83
35.6
35.6
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Indoor
Section
Unit
Size
Capacity
Power
CC5A/CD5AA
CE3AA
042
042
048
048
048
042
048
1.00
1.00
1.01
1.01
1.01
1.00
1.01
1.00
1.00
1.02
1.00
1.00
1.00
1.00
CF5AA
CG5AA
CK3BA
4.18
4.12
4.06
4.05
4.25
4.19
4.14
4.13
4.33
4.27
4.22
4.21
39.1
35.9
32.8
32.1
39.6
36.4
33.5
33.2
40.0
36.7
34.2
34.2
20.0
25.9
31.3
32.1
21.0
27.6
33.1
33.2
21.8
29.1
34.2
34.2
4.58
4.53
4.47
4.46
4.66
4.61
4.55
4.55
4.73
4.66
4.63
4.63
Cooling
Indoor
Section
Unit
Size
Capacity
Power
CK5A/CK5BA
042
048
048
048
042
048
—
1.00
1.01
0.99
1.01
1.00
1.01
—
1.00
1.00
1.00
1.00
1.02
1.02
—
CK5A/CK5BN
CK5A/CK5BW
PF1MNA
PA12NA048-B, C, D Outdoor Section With CC5A/CD5AA048 Indoor Section
1400
1600
1800
72
67
62
57
72
67
62
57
72
67
62
57
54.9
50.5
46.3
43.2
55.9
51.4
47.2
44.9
56.6
52.4
48.1
46.3
26.4
33.0
39.4
43.2
27.4
34.8
41.9
44.9
28.4
36.6
44.3
46.3
3.59
52.7
25.6
4.04
50.3
24.7
4.53
47.9
23.7
3.56
48.4
32.1
4.00
46.2
31.2
4.48
44.0
30.2
3.54
44.4
38.5
3.97
42.4
37.6
4.44
40.3
36.5
3.52
41.8
41.8
3.95
40.2
40.2
4.42
38.7
38.7
3.67
53.6
26.6
4.11
51.1
25.7
4.61
48.5
24.7
3.64
49.3
33.9
4.08
47.0
33.0
4.56
44.6
32.0
3.61
45.2
41.0
4.04
43.1
39.9
4.52
40.9
38.8
3.60
43.3
43.3
4.03
41.7
41.7
4.51
40.0
40.0
3.74
54.2
27.5
4.19
51.7
26.6
4.68
49.0
25.6
3.73
49.9
35.6
4.15
47.6
34.6
4.64
45.1
33.7
3.70
45.8
43.1
4.12
43.7
42.0
4.60
41.5
40.7
3.68
44.6
44.6
4.11
42.9
42.9
4.59
41.1
41.1
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Indoor
Section
Unit
Size
Capacity
Power
CC5A/CD5AA
CC5A/CD5AC
CC5A/CD5AW
060
048
048
060
048
048
060
048
048
060
1.01
0.99
1.00
1.02
1.00
1.00
1.01
1.00
1.00
1.01
1.01
1.00
1.00
1.00
1.00
0.99
0.99
0.99
1.00
0.99
CD5AA
CE3AA
CF5AA
CK3BA
22.8
29.3
35.5
37.0
23.8
31.0
37.6
38.2
24.7
32.7
39.2
39.2
5.63
5.56
5.49
5.47
5.71
5.64
5.58
5.56
5.79
5.72
5.66
5.66
Cooling
Unit
Size
Capacity
Power
CK5A/CK5BA
048
060
048
060
048
060
048
060
070
071
1.00
1.01
1.00
1.01
1.00
1.02
1.00
1.01
1.02
1.02
1.00
0.99
1.00
0.99
1.00
0.99
1.00
1.01
0.99
0.90
CK5A/CK5BW
CK5A/CK5BX
PF1MNB
PF1MNB
PF1MNB
PF1MNB
—11—
45.3
41.7
38.2
37.0
45.9
42.2
38.8
38.2
46.3
42.6
39.3
39.2
Indoor
Section
CK5A/CK5BT
See notes on page 12.
5.06
5.01
4.95
4.92
5.15
5.09
5.03
5.02
5.23
5.17
5.11
5.11
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAPORATOR
AIR
75
85
Capacity
MBtuh†
CFM
EWB
Total
System
Sens‡ kW**
Total
95
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
Capacity
MBtuh†
Total
System
Sens‡ kW**
Total
105
115
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
Capacity
MBtuh†
Total
Total
System
Sens‡ kW**
PA12NA060-A, B Outdoor Section With CC5A/CD5AW060 Indoor Section
1750
2000
2250
72
67
62
57
72
67
62
57
72
67
62
57
66.1
60.8
55.7
52.7
67.4
62.1
56.9
54.6
68.2
62.9
57.7
56.4
32.2
40.6
48.7
52.7
33.6
42.9
51.9
54.6
34.8
45.1
54.7
56.4
4.39
63.8
31.3
4.88
61.4
30.4
5.41
58.5
29.4
4.35
58.6
39.7
4.82
56.2
38.6
5.33
53.5
37.5
4.31
53.7
47.8
4.78
51.4
46.6
5.27
49.0
45.4
4.29
51.0
51.0
4.73
49.3
49.3
5.26
47.5
47.5
4.51
65.1
32.7
4.99
62.3
31.7
5.51
59.3
30.6
4.46
59.6
41.9
4.92
57.0
40.8
5.43
54.2
39.7
4.43
54.7
50.8
4.87
52.3
49.5
5.37
49.7
48.2
4.39
52.9
52.9
4.86
51.1
51.1
5.36
49.0
49.0
4.60
65.8
33.9
5.09
62.9
32.9
5.61
59.8
31.8
4.56
60.4
44.1
5.02
57.6
43.0
5.53
55.0
42.0
4.51
55.4
53.4
4.97
53.2
52.1
5.49
50.7
50.5
4.51
54.5
54.5
4.96
52.4
52.4
5.46
50.6
50.6
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Indoor
Section
Unit
Size
Capacity
Power
CC5A/CD5AW
060
1.00
1.00
CE3AA
CK3BA
060
060
060
1.00
0.96
0.96
0.96
1.00
1.00
CK5A/CK5BA
5.98
5.89
5.83
5.81
6.07
5.99
5.93
5.92
6.18
6.10
6.05
6.05
55.5
50.7
46.5
45.5
56.2
51.3
47.5
46.9
56.5
51.7
48.5
48.1
28.3
36.4
44.2
45.5
29.5
38.5
46.8
46.9
30.7
40.7
48.5
48.1
6.60
6.51
6.44
6.43
6.70
6.61
6.56
6.54
6.80
6.70
6.69
6.65
Cooling
Indoor
Section
Unit
Size
Capacity
CK5A/CK5BX
PF1MNA
060
1.00
1.00
060
070
071
1.00
1.02
1.02
0.98
0.97
0.92
Power
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation, per ARI Standard 210/240-94, and connected by 25 ft of tubing. If
other than 25 ft of tubing is used and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C).
When the required data falls between the published data, interpolation may be performed.
** Unit kW is total of indoor and outdoor unit kilowatts.
SYSTEM DESIGN
1.
2.
3.
4.
5.
6.
Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).
Maximum outdoor operating air temperature is 115°F (46.1°C).
For reliable operation, unit should be level in all horizontal planes.
Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft, indoor coil below = 150 ft.
For interconnecting refrigerant tube lengths greater than 50 ft or 20 ft vertical differential, consult Residential Split System Long-Line Application
Guideline available from equipment distributor.
7. Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft.
8. If any refrigerant tubing is buried, provide a minimum 6 in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in.
may be buried without further consideration. For buried lines longer than 3 ft, consult your local distributor.
9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
Cancels: SS-PA12-03
©2003 Payne Heating & Cooling
P.O. Box 70, Indianapolis, IN 46206
—12—
PRINTED IN U.S.A.
Catalog No. 52PA-123
05-03
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising