VC820 DIGITAL-MULTIMETER HIGHLIGHTS
VOLTC RA F T ® - TOP P ERFORMA NCE IN EVERY WAY
“For more than 25 years, our product range has been dynamically adapting to the constant changes in the industry.
We commit to offering first-class quality to our customers while delivering an excellent cost-performance ratio. This
philosophy remains the cornerstone of Voltcraft’s success.”
VC 8 20
D IG ITAL- M ULT IM E T E R
VERSION 09/14
N º 1 2 32 9 4
The unit comes with optoelectronic interface with beam waveguide technology which enables absolutely safe electric
isolation of the measuring instrument from the PC. This protects your PC against any possible damage which otherwise
might be caused as a result of measuring voltages. Apart from this, the VC820 offers any functions expected of a good
multimeter. In addition to the standard functions such as voltage, current and resistance measurement, the unit enables
frequency and capacity measurement. Selfevidently enough, it also offers diode check, acoustic continuity check and
Low-Bat function. Switching from one measuring range to the other is performed automatically (Auto Range). In addition, the unit offers other concenient special functions such as DATA-HOLD, REL, duty cycle.
H IG HL IGH TS
CAT IV 6 0 0 V //
4 0 0 0 Co u n ts / /
I n terfa ce op ti ca l //
D i o de c h e c k / /
Aco u sti c con tinuity check //
Data - H ol d f u n ction //
D u ty cyc l e / /
TEC H N ICA L DATA
Display
33/4 digit liquid crystal display (LCD), display size of 4000
counts
Speed of measurement
3 measurements per sec.
Input resistance
> 10 MΩ
Over-voltage category
CAT III 1000 V, CAT IV 600 V
Battery replacement symbol
from lower than 7.5 V DC ±0.5 V
Voltage supply
9 V compound battery, type: NEDA 1604 6F22 or 006P or
6LR61
Operating temperature
0 °C to +40 °C
Storage temperature
-10 °C to +50 °C (batteries removed)
Rel. air humidity
< 75 %, non-condensing from 0 °C to +30 °C and < 50%, noncondensing from 31 °C to 40 °C
Operating height
up to max. 2,000 m above MSL
Temperature for guaranteed accuracy
+23 °C ±5K (=Kelvin)
Weight
ca. 300 g (with battery, without measuring lines)
Dimensions (L x W x H)
177 x 85 x 40 mm
Operating mode
Measurement range
Accuracy
Resolution
Direct voltage
400 mV
±(1.0 % + 5 dgts)
0.1 mV
4V
±(0.9 % + 5 dgts)
1 mV
40 V
±(0.9 % + 5 dgts)
10 mV
400 V
±(0.9 % + 5 dgts)
100 mV
1000 V
±(1.4 % + 5 dgts)
1V
Overload protection: 1000 V DC lower than 10 s
Alternating voltage
For input voltages < 50 mV not specified
4V
±(1.5 % + 5 dgts)
1 mV
40 V
±(1.5 % + 5 dgts)
10 mV
400 V
±(1.0 % + 5 dgts)
100 mV
750 V
±(2 % + 5 dgts)
1V
Input resistance > 10 MΩ, frequency of the alternating voltage: 50 Hz to 400 Hz
Overload protection: 750V AC rms < 10 s
Indication at the VC-840 as true effective value (True Rms), crest factor max. 3
Direct current
400 µA
±(1.0 % +5 dgts)
0.1 µA
4000 µA
±(1.0 % +5 dgts)
1 µA
40 mA
±(1.2 % +5 dgts)
0.01 mA
400 mA
±(1.2 % +5 dgts)
0.1 mA
4A
±(1.5 % +5 dgts)
0.001 A
20 A
±(1.5 % +5 dgts)
0.01 A
400 µA
±(2.0 % +5 dgts)
0.1 µA
4000 µA
±(2.0 % +5 dgts)
1 µA
40 mA
±(2.0 % +5 dgts)
0.01 mA
400 mA
±(2.0 % +5 dgts)
0.1 mA
4A
±(2.5 % +5 dgts)
0.001 A
20 A
±(2.5 % +5 dgts)
0.01 A
Overload protection see below
Alternating current
Frequency of the alternating current: 50 Hz to 400 Hz
Overload protection see below
Indication at the VC-840 as true effective value (True Rms), crest factor max. 3
Resistance
400 Ω
±(1.2 % +2 dgts)
0.1 Ω
4 kΩ
±(1.0 % +2 dgts)
0.001 kΩ
40 kΩ
±(1.0 % +2 dgts)
0.01 kΩ
400 kΩ
±(1.0 % +2 dgts)
0.1 kΩ
4 MΩ
±(1.2 % +2 dgts)
0.001 MΩ
40 MΩ
±(1.5 % +2 dgts)
0.01 MΩ
40 nF
±(3.0 % +10 dgts)
0.01 nF
400 nF
±(3.0 % +5 dgts)
0.1 nF
4 µF
±(3.0 % +5 dgts)
0.001 µF
40 µF
±(3.0 % +5 dgts)
0.01 µF
100 µF
±(4.0 % +5 dgts)
0.1 µF
Continuity tester: acoustic signal for resistance values < ca. 70 Ω
Capacity C
Diode test
Ge to GaAs
Test voltage 1 mA max.; emitter diode voltage max. 1.5 V
Frequency
1 mV
5 Hz
±(0.1 % +3 dgts)
0.001 Hz
50 Hz
±(0.1 % +3 dgts)
0.01 Hz
500 Hz
±(0.1 % +3 dgts)
0.1 Hz
5 kHz
±(0.1 % +3 dgts)
0.001 kHz
50 kHz
±(0.1 % +3 dgts)
0.01 kHz
500 kHz
±(0.1 % +3 dgts)
0.1 kHz
5 MHz
±(0.1 % +3 dgts)
0.001 MHz
10 MHz
±(0.1 % +3 dgts)
0.01 MHz
Sensitivity higher or equal to ca. 300 mV eff from 1 Hz to 1 MHz
Sensitivity higher or equal to ca. 600 mV eff from 1 MHz to 10 MHz
Temperature measurement
-40 °C ... 0 °C
±(3.0 % +4 dgts)
1 °C
0 °C ... +400 °C
±(1.0 % +3 dgts)
1 °C
+400 °C ... +1000 °C
±(2.0 % +10 dgts)
1 °C
Temperature measurement possible with VC-840
C
Maximum input values
Voltage measurement:
Max. 1000 V DC or 750 V AC rms
Current measurement:
20 A AC / DC in the A-range, for max. 10 s with a subsequent cool-down phase of min. 15 min., max. 250 V
DC / V AC rms, overload protection: quick-acting 10 A - 250 V fuse 400 mA AC / DC in the mA-range, max.
250 V DC / V AC rms, overload protection: quick-acting 0.5 A - 250 V fuse
Resistance measurement, diode test, continuity check, frequency measurement: max. 1000 V peak
PAC KAGE CONT ENT
Digital multimeter // Optical interface cable // Demosoftware // Instrument leads // Battery (9 V block container) //
Operating instructions
This data sheet is published by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This data sheet represents the technical status at the
time of printing.
© Copyright 2014 by Conrad Electronic SE.
V2_0914_02-ETS-Mkde