em_brochure_part1
EMZ Series
ZOOM STEREO MICROSCOPES
® Crisp, high resolution, precision optics provide an
excellent, erect, unreversed stereoscopic image.
® Rugged all metal body designed to last a lifetime.
* Zoom Range: 0.7X to 4.5X
® Zoom Ratio: 6.5:1
® Ergonomically positioned bilateral zoom controls.
* Binocular eyetubes inclined at 45 for fatigue free
viewing.
® Total magnification range available with auxillary lenses
and eyepieces: 2.1% to 270X.
* Dual dioptric adjustment (+ 5 diopters) allows the
specimen to remain in focus throughout the entire zoom
magnification range.
e Interpupillary distance adjustment from 54mm to 75mm.
® Binocular body can be rotated a full 360 and locked in
any position.
e Standard working distance 93mm.
® Working distance with optional auxiliary lenses:
4mm to 251mm.
EMZ-5 with MA502 SWF10X
EMZ-5 on PK Stand with EMZ-5 on PKL Stand with EMZ-5 on ABE Stand with
MA502 SWF10X eyepieces MA502 SWF10X eyepieces MA502 SWF10X eyepieces
MASOT
MA718
MA502
МА520
MAS03
MAS35
MA504
МАЗОЗ
MAS21
MAS19
MAGOO
EYEPIEGES AND EYEPIEGE ACGCESSORIES
Super Widefield 5X Eyepiece, field No.26
super Widefield 7.5X Eyepiece with 25mm diameter
reticle mount, field No.26
Super Widefield 10X Eyepiece with 25mm diameter
reticle mount, field No.23
Super Widefield 12.5X Eyepiece with 25mm
diameter reticle mount, field No.20
super Widefield 15X Eyepiece with 25mm diameter
reticle mount, field No.15.4
Super Widefield 15X High-eyepoint eyepiece with
25mm diameter reticle mount, field No.16.0
Super Widefield 20X Eyepiece with 25mm diameter
reticle mount, field No.11.5
super Widefield Focusing Eyepiece 20X
with 25mm diameter reticle mount, field No.11.5
Super Widefield 30X Eyepiece field No. 7.7
Super Widefield 10X Focusing eyepiece (single)
with 25mm diameter reticle mount, field No.21
Eyveshields (paired)
Mote: All eyepieces are paired unless otherwise indicated.
MAS23
MA506
MA509
MAS10
MA524
МА542
МА285
МА286
MA287
MA292
= MEL E
> A a Ta,
ra E FA M
\ / \
1 f 1
| | рн)
% y \ /
5, / Е
a > he A
MA523 MAS506
Cross-line, 25mm diameter Jer HE a
10mm divided into100units, 25mm diameter / | h
5mm divided into 100 units, 25mm diameter | Ne an |
10mm square divided into 100 parts, 25mm diameter \ И Ч
(Each side of each individual square 1.0mm) X y \ J
10mm square divided into 400 parts, 25mm diameter
(Each side of each individual square 0.5mm)
Cross-line with 0.01mm graduations, 25mm diameter
1mm divided into 100 units (0.01mm), for transmitted light
0.04" divided into 40 units (0.001"), for transmitted light
0.1mm by 0.1mm counting square for transmitted light
mm divided into 100 parts(0.01mm), for reflected light
y
A,
er ar
Fa
Lo y”
MA530
МА525
MAS17
MA526
MA507
MAS11
MAS45
MAS58
MA546
MAS47
MA548
MA549
MA791
MA792
MA794
MA795
MAB8OZ
MA515
MAS18
MAS27
MA513
MAS14
“NOTE
MA652
MA796
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Adapter”
Auxiliary
Auxiliary
Auxiliary
Auxiliary
lens 0.3X, Working distance 251mm
lens 0,44X, Working distance 171mm
lens 0.5X, Working distance 148mm
lens 0.75X, Working distance 97mm
lens 1.5X, Working distance 49mm
lens 2.0X, Working distance 33mm
MAS17 MA507
lens 0.3X, Working distance 326mm
lens 0.44X. Working distance 247mm
lens 0.5X, Working distance 194mm
lens 0.754, Working distance 127mm
lens 1.5X, Working distance 64mm
lens 2.0X, Working distance 44mm
lens 0.28x, Working distance 300mm
lens 0.35X, Working distance 280mm
lens 0.54, Working distance 174mm
lens 1.5X, Working distance 57mm
lens 2.0X, Working distance 36.6mm
lens 0.5X, Working distance 108mm
lens 0.75X, Working distance 72mm
lens 1.54, Working distance 35mm
lens 2.0X, Working distance 22mm
МА518 МА513
=
: The MASTS adapter is required when using
the MAS18, MA527, MA513, or MA514 with the EMT-2 and EMTR-2
El ] AILIAR Y
Auxiliary lens 0.7X Working distance 233mm
Auxiliary lens 0.57 X Working distance 300mm
=
MA652
MA796
= MEW!
13
FOCUSING BLOCKS
F HOLDER
Focusing slide block designed to hold the stereo
microscope body on machines or for special OEM
applications. Rack and pinion mount allows smooth,
precise focusing over 55mm of travel. Coarse focus
mechanism incorporates a slip clutch and tension
adjustment. Fits 20mm mounting post, 84. 2mm
diameter opening accepts 84mm stereo microscope
body.
OLDE!
Focusing side block designed to hold the stereo
microscope body on machines or for special OEM
applications. Rack and pinion mount allows
smooth, precise focusing. Coarse focus mechanism
incorpoates a ship clutch and tension adjustment
Distance from center of holder to center of pillar is
27.8mm longer than other holders ike F, FX, FS and
FSC holders, Therefore, when using trinocular
microscope bodies like EMZ-BTH or EMZ-13TH,
it rotates smoothly without the part of straight lube
protruded louching holder
DER
Special lilting locusing slide block with integral
Muminator por designed to hold the stereo microscope
body on machines or for special OEM applications
Rack and pinion mount allows smooth, precise focusing
over 55mm of travel. Coarse focus mechanism
incorporates a ship clutch and tension adjustment,
15.8mm (5 / 8") mounting pin, 84.2mm diameter
opening accepts 84mm stereo microscope body
Travel
= #20 +84.2 range:55mm
— - лини: = a — i
FX width: 113mm
Pole-type
STANDS
P STAND
Pole-type stand with F holder focus block mounted on a plain base. Supplied
with one 94. 5mm diameter reversible black and white stage plate and two
stage clips.
sions: Length: 230mm. Width: 150mm
Height: 248mm. Pillar Diameter: 20mm
Pole-type stand with F holder focus block mounted on a
plain flat base making much of stability and work-efficiency.
PK stand accepts all MEIJI EM series binocular stereo
microscope bodies.
F holder can be fixed at any position of pole. Supplied with
one 94.5mm diameter reversible black and while stage
plate and two stage chips
Dimensions:
Length: 265mm. Width: 330mm
Height: 280mm. Pillar Diameter: 20mm
PL STAND
Fole type stand with FX holder focus block with incident light illuminator port
mounted on a plain base. Supplied with one 94. 5mm diameter reversible
black and white stage plate and two stage clips.
Length: 230mm." Width: 150mm
Height: 248mm. Pillar Diameter: 20mm
Pole-type
Pole-type stand with F holder focus block mounted on a flat base with
integrated LED transmitted and incident illumination system. Automatic
Voltage sensing power supply is incorporated.
PKL stand accepts all MEIJI EM Series binocular and trinocular bodies.
Dimensions: Length: 300mm.~ Width: 320mm
Height: 265mm, Pillar Diameter: 20mm
Pole-type stand with FX holder focus block with incident illuminator port.
Transmitted light base includes a fully rotatable mirror for brightfield or
"pseudo" darkfield work. Supplied with a 94. 5mm diameter clear glass
stage plate and two stage clips. Base and focus block accept optional
versatile type illuminators. (MA264H or MA264)
Dimensions Length: 240mm. Width: 160mm
Height: 280mm.” Pillar Diameter: 20mm
Bulbs: Incident: MAS70.7 Trans: MAST0