OLSSC Brochure Rev. 11-12
Olsen OLSSC Natural or Propane Gas-Fired Modulating Condensing Hot Water Boiler
Dimensions/Weights
Front
B
Boiler Input Rate
(MBH) (1)
Max.
Min.
Heating
Capacity
(MBH) (1)(2)
OLSSC-050
50
10
46
40
95%
OLSSC-075
75
15
69
60
95%
OLSSC-100
100
20
91
79
95%
OLSSC-150
150
30
139
121
95%
OLSSC-200*
200
40
185
161
94%
Model
Net AHRI
Rating, Water
(MBH) (1) (3)
AFUE % (2)
* The UBSSC-200 has an AFUE of 94% and is an ENERGY STAR rated product but it does not meet the 95% criteria for 2012 Most Efficient.
(1) 1000 Btu/hr (British Thermal Units Per Hour)
(2) Heating Capacity and AFUE (Annual Fuel Utilization Efficiency) are based on DOE (Department of Energy) test procedures.
(3) Net AHRI Ratings based on piping and pickup allowance of 1.15. Contact Technical Support before selecting boiler for installations having unusual piping and
pickup requirements, such as intermittent system operation, extensive piping systems, etc.
General Information
A
(See Installation, Operation and Maintenance Manual for complete instructions)
Combustible Materials
(4)
(Required)
Top
C
Bottom
Clearances
(4) Required
distances
measured from
boiler.
(5) Service,
proper operation
clearance
recommendation.
Back
D
Top
0” (0 cm)
0” (0 cm)
0” (0 cm)
Right Side
0” (0 cm)
0” (0 cm)
Front
0” (0 cm)
6” (16 cm)
Back
0” (0 cm)
0” (0 cm)
Bottom
0” (0 cm)
12” (32 cm)
Combustion Air/Vent Piping
050
075
100
150
200
Width
(A)
20”
508 mm
23”
584 mm
Height
(B)
31”
787 mm
42”
1092 mm
Depth
(C)
14”
356 mm
16”
406 mm
Bracket
(D)
28”
711 mm
40”
1016 mm
Min. Length
Max. Length
0” (0 cm)
6” (16 cm)
1/2” (1.3 cm)
6” (16 cm)
2” Pipe
050
2” Pipe
075/100
3” Pipe
075/100
3” Pipe
150/200
6 Ft.
(1.8 m)
6 Ft.
(1.8 m)
6 Ft.
(1.8 m)
6 Ft.
(1.8 m)
100 Ft.
(30.5 m)
50 Ft.
(15.2 m)
100 Ft.
(30.5 m)
100 Ft.
(30.5 m)
Modulating Condensing
Gas Boilers
Up to 95% A.F.U.E.
Natural gas or propane
OLSSC
50-200 MBH
Notes: 1 - 90° Elbow = 5 Ft. (1.6 m), 1 - 45° Elbow = 3.5 Ft. (1.1 m), 1 - 2” x 3” Adapter = 0 Ft. (0 m),
Concentric Vent Kit = 5 Ft. (1.6 m) equivalent length.
Return/Supply Water
Gas In
Condensate Drain
050/075/100
1-1/4” NPT
1/2” NPT
3/4” NPT
150/200
1-1/4” NPT
3/4” NPT
3/4” NPT
Electrical
120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended)
Water Content
050/075/100 - 1.1 Gallons, 150/200 - 1.8 Gallons
Standard
Equipment
Mounting Wall: Wall Bracket included.
Boiler Control Module: Automatic Low Voltage/Intermittent Power Reset. Controls up to 16 boilers
for multiple boiler applications.
User Display interface: Easy programming with text display. Remote mount option utilizes
standard thermostat conductor wiring. Outdoor Temperature Sensor included.
Heat Exchanger: High grade 316L/444 Stainless Steel Fin Coil with Flame Sight Glass.
Built-in Primary/Secondary Manifold Piping and Pump.
Combustion: Gas Valve with Premix Venturi and Blower, Durable Stainless Steel Mesh Modulating
Burner with 5:1 turn down ratio, Direct Spark Igniter, Flame Sensor and LP Conversion Kit included.
Electrical: Detachable Low Voltage Terminal Strip, High Voltage Junction Box and Transformer.
Other: Factory installed probe-type Low Water Cut Off with test feature, 30 PSI Safety Relief Valve,
Boiler Drain Valve and Condensate Drain with built in trap.
Options
gas fired water boilers
14” (36 cm)
Connections
Dimensions
Models
(5)
Left Side
Hot Water Piping
Combustion Air &
Vent Pipe
Equivalent
Length (Schedule
40 PVC)
Service
•
•
•
Wall Mounted
Innovative Design
Superior Savings
ENERGY STAR
Central Heating Pump (Taco 007 or Grundfos UP15-42F), Concentric Vent Kit (2” and 3”),
System Sensor (For Multiple Boiler Applications), Computer Interface
Weights
Ship
Wgt.
111 lbs.
50 kg
~ 182 lbs.
83 kg
Boiler
Wgt.
91 lbs.
41 kg
~ 157 lbs.
71 kg
Certifications
ENERGY
STAR ENERGY STAR
ENERGY
STAR
C
C
US
US
All ratings and specifications subject to change.
PN 240009037 Rev. 11/12
ECR International
2201 Dwyer Ave., Utica, NY 13504
Tel: (315) 797-1310 or (800) 325-5479
Fax: (315) 724-9319
Web: www.ecrinternational.com
keeping families warm for more than 60 years
Dependability is simply part of our heritage.
The Olsen OLSSC “Stainless Steel Condensing” boiler features our own original heat exchanger design. This
revolutionary 316L/444 stainless steel fin tube design is the perfect example of the ingenuity and resourcefulness
that define Olsen Boilers. We actively strive to incorporate design elements that ultimately mean better value to
the consumer both today and over time. That’s because your home heating system is more than just a one-time
investment. Home heating really goes beyond the initial cost of the system. Your boiler selection impacts the family
budget every time you get a utility bill. Efficiency, ease of maintenance and longevity are key. No one wants to
be caught off guard by a runaway home heating bill or costly maintenance and repairs.
Factory wired and installed,
probe-type low water cut off
with test button.
“With an old, inefficient boiler you could be throwing away
up to 30% of the money you spend on fuel each year.”
Control features simple text display,
outdoor reset, priority domestic
hot water and integrated multiple
boiler control capability for up to
16 boiler modules. Can be remotely
mounted with standard thermostat
conductor wiring.
Corrosion resistant
CPVC flue collector.
An older, lower efficiency heating system can have an annual fuel utilization efficiency (AFUE) 70%.
That means 70% of the energy in the fuel you buy becomes heat for the home and the other 30% escapes
up the chimney and elsewhere. You wouldn’t throw away a third of the groceries you put in your cart
each week, so why continue to waste money on fuel.
The Olsen OLSSC features up to 95% AFUE.
Just add up the savings:
• Up to 95% AFUE
• Sealed Combustion
Original 316L/444
stainless steel fin
tube heat exchanger.
Built in primary/secondary
piping with pump.
• Outdoor Temperature Reset*
*A factory standard Outdoor Temperature Reset adjusts water supply temperature for best possible fuel economy based on actual seasonal conditions.
Integral Condensate Trap.
The increased efficiency of the OLSSC could save you up to 40% on your heating bill each year.
If you pay $1,750 annually to heat your home, you could save as much as $700 per year.
That’s $3,500 over 5 years!t
t
Individual savings may vary.
It’s not just about efficiency either.
The OLSSC’s original design incorporates easy maintenance, durability and safety to make the most of your home heating investment.
The self cleaning heat exchanger features wide smooth waterways that help remove hard water deposits and prevent scaling. A corrosion
resistant CPVC flue collector adds to the longevity of the boiler. The OLSSC’s sealed housing reduces noise for quiet comfort in any living
space. Since most municipal codes require heating systems to incorporate a Low Water Cut Off (LWCO) to guard against unsafe operation,
the Olsen OLSSC features a built-in LWCO.
Simplified electrical connections
with removable terminal block.
Wall mount bracket included
Top Connections
Bottom Connections
Olsen actively holds our products to a high standard
of quality and stands behind them.
Each OLSSC boiler produced is subjected to a rigorous set of quality control checks before it leaves our factory. Olsen checks
all of the electrical, plumbing, pressure vessel and combustion set up parameters prior to approving an OLSSC for shipment.
We even include the final computer generated results for your professional contractor to reference while completing your
installation. Every Olsen OLSSC Boiler is backed by a 15 year limited manufacturer’s heat exchanger warranty.
Jacket slides on and off for
quick access.
Replacement ready with 1-1/4” piping
connections and low pressure drop no high head pump required.
Ask your installer about
Argo Boiler Controls for a
professional installation.
Dependability is simply part of our heritage.
The Olsen OLSSC “Stainless Steel Condensing” boiler features our own original heat exchanger design. This
revolutionary 316L/444 stainless steel fin tube design is the perfect example of the ingenuity and resourcefulness
that define Olsen Boilers. We actively strive to incorporate design elements that ultimately mean better value to
the consumer both today and over time. That’s because your home heating system is more than just a one-time
investment. Home heating really goes beyond the initial cost of the system. Your boiler selection impacts the family
budget every time you get a utility bill. Efficiency, ease of maintenance and longevity are key. No one wants to
be caught off guard by a runaway home heating bill or costly maintenance and repairs.
Factory wired and installed,
probe-type low water cut off
with test button.
“With an old, inefficient boiler you could be throwing away
up to 30% of the money you spend on fuel each year.”
Control features simple text display,
outdoor reset, priority domestic
hot water and integrated multiple
boiler control capability for up to
16 boiler modules. Can be remotely
mounted with standard thermostat
conductor wiring.
Corrosion resistant
CPVC flue collector.
An older, lower efficiency heating system can have an annual fuel utilization efficiency (AFUE) 70%.
That means 70% of the energy in the fuel you buy becomes heat for the home and the other 30% escapes
up the chimney and elsewhere. You wouldn’t throw away a third of the groceries you put in your cart
each week, so why continue to waste money on fuel.
The Olsen OLSSC features up to 95% AFUE.
Just add up the savings:
• Up to 95% AFUE
• Sealed Combustion
Original 316L/444
stainless steel fin
tube heat exchanger.
Built in primary/secondary
piping with pump.
• Outdoor Temperature Reset*
*A factory standard Outdoor Temperature Reset adjusts water supply temperature for best possible fuel economy based on actual seasonal conditions.
Integral Condensate Trap.
The increased efficiency of the OLSSC could save you up to 40% on your heating bill each year.
If you pay $1,750 annually to heat your home, you could save as much as $700 per year.
That’s $3,500 over 5 years!t
t
Individual savings may vary.
It’s not just about efficiency either.
The OLSSC’s original design incorporates easy maintenance, durability and safety to make the most of your home heating investment.
The self cleaning heat exchanger features wide smooth waterways that help remove hard water deposits and prevent scaling. A corrosion
resistant CPVC flue collector adds to the longevity of the boiler. The OLSSC’s sealed housing reduces noise for quiet comfort in any living
space. Since most municipal codes require heating systems to incorporate a Low Water Cut Off (LWCO) to guard against unsafe operation,
the Olsen OLSSC features a built-in LWCO.
Simplified electrical connections
with removable terminal block.
Wall mount bracket included
Top Connections
Bottom Connections
Olsen actively holds our products to a high standard
of quality and stands behind them.
Each OLSSC boiler produced is subjected to a rigorous set of quality control checks before it leaves our factory. Olsen checks
all of the electrical, plumbing, pressure vessel and combustion set up parameters prior to approving an OLSSC for shipment.
We even include the final computer generated results for your professional contractor to reference while completing your
installation. Every Olsen OLSSC Boiler is backed by a 15 year limited manufacturer’s heat exchanger warranty.
Jacket slides on and off for
quick access.
Replacement ready with 1-1/4” piping
connections and low pressure drop no high head pump required.
Ask your installer about
Argo Boiler Controls for a
professional installation.
Olsen OLSSC Natural or Propane Gas-Fired Modulating Condensing Hot Water Boiler
Dimensions/Weights
Front
B
Boiler Input Rate
(MBH) (1)
Max.
Min.
Heating
Capacity
(MBH) (1)(2)
OLSSC-050
50
10
46
40
95%
OLSSC-075
75
15
69
60
95%
OLSSC-100
100
20
91
79
95%
OLSSC-150
150
30
139
121
95%
OLSSC-200*
200
40
185
161
94%
Model
Net AHRI
Rating, Water
(MBH) (1) (3)
AFUE % (2)
* The OLSSC-200 has an AFUE of 94% and is an ENERGY STAR rated product but it does not meet the 95% criteria for 2012 Most Efficient.
(1) 1000 Btu/hr (British Thermal Units Per Hour)
(2) Heating Capacity and AFUE (Annual Fuel Utilization Efficiency) are based on DOE (Department of Energy) test procedures.
(3) Net AHRI Ratings based on piping and pickup allowance of 1.15. Contact Technical Support before selecting boiler for installations having unusual piping and
pickup requirements, such as intermittent system operation, extensive piping systems, etc.
General Information
A
(See Installation, Operation and Maintenance Manual for complete instructions)
Combustible Materials
(4)
(Required)
Top
C
Bottom
Clearances
(4) Required
distances
measured from
boiler.
(5) Service,
proper operation
clearance
recommendation.
Back
D
Top
0” (0 cm)
0” (0 cm)
0” (0 cm)
Right Side
0” (0 cm)
0” (0 cm)
Front
0” (0 cm)
6” (16 cm)
Back
0” (0 cm)
0” (0 cm)
Bottom
0” (0 cm)
12” (32 cm)
Combustion Air/Vent Piping
050
075
100
150
200
Width
(A)
20”
508 mm
23”
584 mm
Height
(B)
31”
787 mm
42”
1092 mm
Depth
(C)
14”
356 mm
16”
406 mm
Bracket
(D)
28”
711 mm
40”
1016 mm
Min. Length
Max. Length
0” (0 cm)
6” (16 cm)
1/2” (1.3 cm)
6” (16 cm)
2” Pipe
050
2” Pipe
075/100
3” Pipe
075/100
3” Pipe
150/200
6 Ft.
(1.8 m)
6 Ft.
(1.8 m)
6 Ft.
(1.8 m)
6 Ft.
(1.8 m)
100 Ft.
(30.5 m)
50 Ft.
(15.2 m)
100 Ft.
(30.5 m)
100 Ft.
(30.5 m)
Modulating Condensing
Gas Boilers
Up to 95% A.F.U.E.
Natural gas or propane
OLSSC
50-200 MBH
Notes: 1 - 90° Elbow = 5 Ft. (1.6 m), 1 - 45° Elbow = 3.5 Ft. (1.1 m), 1 - 2” x 3” Adapter = 0 Ft. (0 m),
Concentric Vent Kit = 5 Ft. (1.6 m) equivalent length.
Return/Supply Water
Gas In
Condensate Drain
050/075/100
1-1/4” NPT
1/2” NPT
3/4” NPT
150/200
1-1/4” NPT
3/4” NPT
3/4” NPT
Electrical
120 Volts AC, 60 hertz, 1 phase, Less than 12 amps (15 amp circuit recommended)
Water Content
050/075/100 - 1.1 Gallons, 150/200 - 1.8 Gallons
Standard
Equipment
Mounting Wall: Wall Bracket included.
Boiler Control Module: Automatic Low Voltage/Intermittent Power Reset. Controls up to 16 boilers
for multiple boiler applications.
User Display interface: Easy programming with text display. Remote mount option utilizes
standard thermostat conductor wiring. Outdoor Temperature Sensor included.
Heat Exchanger: High grade 316L/444 Stainless Steel Fin Coil with Flame Sight Glass.
Built-in Primary/Secondary Manifold Piping and Pump.
Combustion: Gas Valve with Premix Venturi and Blower, Durable Stainless Steel Mesh Modulating
Burner with 5:1 turn down ratio, Direct Spark Igniter, Flame Sensor and LP Conversion Kit included.
Electrical: Detachable Low Voltage Terminal Strip, High Voltage Junction Box and Transformer.
Other: Factory installed probe-type Low Water Cut Off with test feature, 30 PSI Safety Relief Valve,
Boiler Drain Valve and Condensate Drain with built in trap.
Options
gas fired water boilers
14” (36 cm)
Connections
Dimensions
Models
(5)
Left Side
Hot Water Piping
Combustion Air &
Vent Pipe
Equivalent
Length (Schedule
40 PVC)
Service
•
•
•
Wall Mounted
Innovative Design
Superior Savings
ENERGY STAR
Central Heating Pump (Taco 007 or Grundfos UP15-42F), Concentric Vent Kit (2” and 3”),
System Sensor (For Multiple Boiler Applications), Computer Interface
Weights
Ship
Wgt.
111 lbs.
50 kg
~ 182 lbs.
83 kg
Boiler
Wgt.
91 lbs.
41 kg
~ 157 lbs.
71 kg
Certifications
ENERGY
STAR ENERGY STAR
ENERGY
STAR
C
C
US
US
All ratings and specifications subject to change.
PN 240009037 Rev. 11/12
ECR International
2201 Dwyer Ave., Utica, NY 13504
Tel: (315) 797-1310 or (800) 325-5479
Fax: (315) 724-9319
Web: www.ecrinternational.com
keeping families warm for more than 60 years
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising