electric combination boiler ECB 210

electric combination boiler ECB 210
ELECTRIC COMBINATION BOILER
electric combination
boiler ECB 210
Pre wired and pre plumbed
electric boiler for mains pressure hot water
and vented central heating systems
This electric combination boiler will provide hot water and
central heating in one compact unit and comes complete
with programmers, pump and immersion heaters ready to
plumb straight into your radiator circuit. All hot water controls
are fitted too, for a fast and professional installation.
Suitable for all single bathroom electric
apartments with four to five radiators
Pre wired and pre plumbed
Self commissioning wet central heating
Mains pressure hot water for fast bath
filling and power showering
Safe vented 210 litre store
Danfoss wireless room thermostat/
central heating programmer
Timer for off peak electricity
6kw and 3kw immersion heaters fitted
A rated pump fitted and wired
Stainless thermal store
with 10 year guarantee
The ECB 210 is a plug and play
solution for mains hot water and vented
heating in the all electric apartment.
The hard work is taken out of the
installation as the unit is pre wired
and pre plumbed. A few wiring and
plumbing connections are all that is
required to fit this smart stainless steel
unit. It is supplied as shown above.
Overflow
Vent &
Water
Level
Indicator
Cold
Section
Isolation
Value
Blending
Valve
Hot
Out
2L
Expansion
Vessel
Temperature
Gauge
Hot
Water
Coil
Service
Valve
HTG Flow
Cold
In
Drain
3kw
Immersion
Heater
HTG Return
6kw
Immersion
Heater
ELECTRIC COMBINATION BOILER
ECB 210 operation
the wiring centres
The Advance Electric Combination boiler is perfect for modern all electric apartment
dwellers who prefer the comfort of wet central heating systems and mains pressure hot
water for powerful showers and quick bath filling.
Two programmers are fitted and wired, one for off peak (usually overnight) electricity tariffs and
one for switching the central heating on and off during the day. The central heating programmer/
room thermostat is wireless and can be used without the need for additional wiring.
3 Amp Live
3 Amp Neutral
3 Amp Earth
There is sufficient hot water from an overnight charge for a shower and a bath.
A second immersion heater is fitted for hot water boost.
The product meets HWA Thermal Store Specification and part G and L of the Building Regulations.
The lower part of the store is dedicated to central heating. A 6kw immersion heater is
fitted for this purpose, and can be used in systems up to four or five radiators. During
start up periods the energy stored in the lower part of boiler is ready for immediate
use. If the water in the radiators falls overnight to 20 °C, for example, the 6kw heater is
adequate for demand of up to 10kw when first switched on in the day.
When heating is switched on water is pumped from the store to the radiators and has the
benefit of providing immediate heat. Using the off-peak controller, the immersion heater
will have heated the store to 75 °C which is the recommended temperature.
A temperature gauge is fitted for convenience and diagnostics.
In the higher part of the tank is a large efficient hot water coil which draws heat from
the store for hot outlets in the property. It is connected to the mains so provides fast
safe hot water to all outlets without the need for pumps.
Your morning shower will not be compromised if the heating is on.
wiring schematic
30 Amp Live
30 Amp Neutral
Earth
kw
kw
kw
specification
CAPACITY
HEATING RATING WEIGHT FULL
210 HOT 20 COLD 6KW TO 10KW
250KG
HGT x DIA
HEAT LOSS
1750 x 600
1.92KWHR/24HRS
Full instructions are supplied
with the unit for the plumbing
and wiring. A dedicated 30 amp
supply will be required for the
6kw immersion heater supply in
addition to a 3 amp supply for
the programmers and pump as
shown above.
ECB 210 Installation
The ECB is pre wired. The installer must be a qualified electrician and meet all
appropriate current Regulations and Codes of Practice.
A 3 amp supply is to be wired to the main junction box as indicated in the box.
The large contactor must have a 30 amp switched supply connected as directed above.
This supply must be direct from the board in the property.
It must be connected by a suitably qualified electrician and all relevant and current Building
Regulations and Codes of Practice must be observed.