LS-3100 - Varispeed

LS-3100 - Varispeed
MAIN MENU
PRODUCTS
APPLICATIONS
Multi-functional
Laser Scan
Micrometers
INDEX
SELECTION GUIDE
Description
Simultaneous 2-point measurement and dual display
LS-3100 Series
The LS-3100 can simultaneously measure two attributes of one target,
or one attribute of two targets, with a single scanning head.
Both results are displayed simultaneously.
Eccentricity
Dia. A
Features
●
●
●
●
Diameter
Dia. B
Simultaneous 2-point measurement
Dual display capabilities
4 segment modes
Industry-standard interfaces
2 targets
2 attributes
Connect 2 scanning heads to one controller
When two scanning heads are employed, the LS-3100 can perform the
following eight calculations for greater application flexibility.
Measuring range
Fine measuring - 0.08 to 30 mm dia.
X & Y, X + Y, X - Y
X +Y
,
2
(0.003" to 1.18")
Standard - 0.3 to 30 mm dia. (0.01" to 1.18")
X -Y
2
,
-X & -Y, - (X + Y), -
( X +2 Y )
Wide range - 0.8 to 60 mm dia. (0.03" to 2.36")
Measure targets from 80 µm 3.12 Mil to 60 mm 2.36"
A 0.1 µm 0.004 Mil resolution enables accurate measurement of
targets up to 60 mm 2.36" in diameter. A variety of targets ranging from
extra fine optical fibers to large diameter pipes can be measured with
high accuracy.
4 segment modes
Four segment modes are available; DIA, EDGE1, EDGE2, SEG (m, n).
Up to 2 segment modes may be in operation at the same time.
EDGE1
DIA.
EDGE2
Reliable measurement of transparent targets
The LS-3100 accurately detects the edges or borders where the target
interrupts the laser beam and processes the detection signal using a
microcomputer, thus enabling transparent as well as opaque targets to
be measured. Highly accurate measurement can be performed without
special operations or adjustments even for transparent objects.
Multi-functional
The LS-3100 provides the following functions for maximum versatility:
•
•
•
•
•
•
•
•
Refer to P.551 for a list of products
complying with EMC directive.
426
Storage of up to 10 tolerance and parameter settings
7-level comparator/3-level comparator
Display units selectable (mm/in)
Auto-zero
Offset
Number of averaging measurements
Analog voltage output scaling
Parameter protection (lock)
Versatile interfaces
The LS-3100 Series features a variety of interfaces to meet your
needs. RS-232C, Analog voltage output, and Control I/O interfaces are
standard. Optional GP-IB and BCD interfaces are also available.
MAIN MENU
PRODUCTS
APPLICATIONS
INDEX
SELECTION GUIDE
Multi-functional Laser Scan Micrometers
LS-3100
Applications
Simultaneous measurement of
roller diameter and eccentricity
Measurement of
electrical wire
Simultaneous measurement of gap
and diameter of multiple targets
)
( X+Y
2
Measurement of sheet thickness
(X-Y)
Measurement of transparent
target outer diameter
Measurement of IC lead pitch
(Segment m, n)
Control of sheet edges
Measurement of target width
Selection Chart
Measuring
range
Scanning head
shape
0.08 mm
0.003"
Measuring
accuracy
Light source
(Semiconductor laser)
30 mm
1.18"
±2 µm
±0.08 Mil
0.3 mm
0.01"
0.8 mm
0.003"
30 mm
1.18"
60 mm
2.36"
0.08 mm
0.003"
30 mm
1.18"
0.5 mm
0.02"
30 mm
1.18"
Controller
Display resolution
0.1 µm 0.004 Mil
LS-3034
760 nm
(Infrared)
LS-3032
670 nm
(Red)
±3 µm
±0.12 Mil
±2 µm
±0.08 Mil
Scanning
head
670 nm
(Red)
760 nm
(Infrared)
LS-3036
LS-3100,
1.
LS-3100D
LS-3060
LS-3033 SO
(8073)
LS-3033
1. The LS-3100D is a controller to which two sets of the scanning heads can be connected.
427
MAIN MENU
PRODUCTS
APPLICATIONS
INDEX
SELECTION GUIDE
LS-3100 Multi-functional Laser Scan Micrometers
Specifications
Standard controller
Type
Fine measuring
Scanning head type
Model
Scanning head
Standard
Single-body
Separate
Single-body
Separate
Single-body
Separate
LS-3034
LS-3033 SO
(8073)
LS-3032
LS-3033
LS-3036
LS-3060
0.3 to 30 mm
0.01" to 1.18"
0.8 to 60 mm
0.03" to 2.36"
Standard controller
Measuring Scanning head
range
Controller
LS-3100
0.08 to 30 mm 1. 0.08 to 30 mm 1.
0.003" to 1.18" 0.003" to 1.18"
0.3 to 30 mm
0.01" to 1.18"
0.08 mm 0.003" 0.08 mm 0.003"
0.3 mm 0.01"
0.5 mm 0.02"
0.3 mm 0.01"
0.8 mm 0.03"
60 mm 2.36"
120 ±40 mm
4.72" ± 1.57"
60 mm 2.36"
200 ±50 mm
7.87" ± 1.97"
0.5 to 30 mm
0.02" to 1.18"
mm/inch selectable
Minimum target width
T and R distance
60 mm 2.36"
Light source
120 mm 4.72"
(Fixed)
Infrared semiconductor laser
Wavelength
Class
Wide range
FDA
IEC
Measuring accuracy
Red semiconductor laser
780 nm
780 nm
780 nm
780 nm
670 nm
670 nm
Class I
Class I
Class I
Class I
Class II
Class II
Class 1
Class 1
Class 1
Class 1
Class 1
Class 1
±2 µm max.2.
0.08 Mil
±2 µm max.2.
0.08 Mil
±2 µm max.2.
0.08 Mil
±2 µm max.2.
0.08 Mil
±2 µm max.2.
0.08 Mil
±3 µm max.3.
0.1 Mil
Repeatability
0.3 µm 0.01 Mil 0.3 µm 0.01 Mil 0.3 µm 0.01 Mil 0.3 µm 0.01 Mil 0.3 µm 0.01 Mil 0.5 µm 0.02 Mil
Display resolution
0.1 µm 0.004 Mil 0.1 µm 0.004 Mil 0.1 µm 0.004 Mil 0.1 µm 0.004 Mil 0.1 µm 0.004 Mil 0.1 µm 0.004 Mil
Laser scan rate
Laser scan velocity
400 scans/s
400 scans/s
400 scans/s
400 scans/s
400 scans/s
400 scans/s
63 m/s 206.7'
63 m/s 206.7'
63 m/s 206.7'
63 m/s 206.7'
63 m/s 206.7'
126 m/s 413.4'
Laser scan range
Approx. 65 mm
2.56"
Approx. 33 mm 1.30"
Main display: 7-segment green LED (8 digits)
Sub display: 16 character x 2 line LCD (Backlight color: yellow-green)
Measured value
Minimum display unit
0.1 µm 0.004 Mil /0.2 µm 0.008 Mil
Display range
-999.9999 to 9999.9999
Target position indicator
Green LED (7 levels)
Comparator output indicator
Green LED x 3 (HI/GO/LO)
Laser emission indicator
Green LED x 2 (HEAD 1/ HEAD 2)
Hold synchronous, LASER REMOTE, PROGRAM SELECT (Program Nos. 1 to 5)
Control I/O
Non-voltage input (contact/solid state)
Analog voltage
±6 V, Output impedance: 0 Ω
Contact output
Relay output: 3PST-NO contact, 250 VAC, 2 A (resistive load)
Control input
36-pin
connector
I/O
Control
7-level/3-level
output
Hold synchronous, AUTO ZERO SET/ RESET, PROGRAM SELECT (Program Nos. 1 to 5)
TTL level, negative logic
40 mA max. (30 V max.)
Interface port
RS-232C/GP-IB (optional)/ BCD (optional)
Power supply
85 to 264 VAC, 50/60 Hz
Power consumption
40 VA max.
40 VA max.
40 VA max.
40 VA max.
40 VA max.
40 VA max.
Ambient
temperature
0 to +45°C
0 to +45°C
0 to +45°C
0 to +45°C
0 to +40°C
0 to +40°C
0 to +40°C
0 to +40°C
0 to +40°C
0 to +40°C
0 to +40°C
0 to +40°C
0.8 kg
T: 0.5 kg
R: 0.4 kg
0.8 kg
T: 0.5 kg
R: 0.4 kg
0.8 kg
Approx. 2.5 kg
(base included)
Weight
Scanning head
Controller
Scanning head
Controller
4.
Approx. 4.6 kg
1. When the outer diameter is measured.
2. When a rod 10 mm 0.39" in diameter is measured in a 2 x 20 mm 0.08" x 0.79", 4 x 20 mm 0.16" x 0.79", or 10 x 20 mm 0.39" x 0.79" measuring area.
3. When measuring a rod 20 mm 0.79" in diameter in a 20 x 40 mm 0.79" x 1.57" measuring area.
4. ‘T’ indicates a transmitter, ‘R’ indicates a receiver.
428
MAIN MENU
PRODUCTS
APPLICATIONS
INDEX
SELECTION GUIDE
Multi-functional Laser Scan Micrometers
LS-3100
2-head controller
Type
Fine measuring
Scanning head type
Model
Scanning head
Standard
Separate
Single-body
Separate
Single-body
Separate
LS-3034
LS-3033 SO
(8073)
LS-3032
LS-3033
LS-3036
LS-3060
0.3 to 30 mm
0.01" to 1.18"
0.8 to 60 mm
0.03" to 2.36"
2-head controller
LS-3100D
Measuring Scanning head
range
Controller
0.08 to 30 mm 1. 0.003" to 1.18"
Minimum target width
0.08 mm 0.003" 0.08 mm 0.003"
0.3 to 30 mm
0.01" to 1.18"
0.5 to 30 mm
0.02" to 1.18"
mm/inch selectable
T and R distance
60 mm 2.36"
Light source
120 mm 4.72"
(Fixed)
0.3 mm 0.01"
0.5 mm 0.02"
0.3 mm 0.01"
0.8 mm 0.03"
60 mm 2.36"
120 ±40 mm
4.72" ± 1.57"
60 mm 2.36"
200 ±50 mm
7.87" ± 1.97"
Infrared semiconductor laser
Wavelength
Class
Wide range
Single-body
780 nm
780 nm
Red semiconductor laser
780 nm
780 nm
670 nm
670 nm
Class II
FDA
Class I
Class I
Class I
Class I
Class II
IEC
Class 1
Class 1
Class 1
Class 1
Class 1
Class 1
±2 µm max.2.
0.08 Mil
±2 µm max.2.
0.08 Mil
±2 µm max.2.
0.08 Mil
±2 µm max.2.
0.08 Mil
±2 µm max.2.
0.08 Mil
±3 µm max.3.
0.01 Mil
Measuring accuracy
Repeatability
0.3 µm 0.01 Mil 0.3 µm 0.01 Mil 0.3 µm 0.01 Mil 0.3 µm 0.01 Mil 0.3 µm 0.01 Mil 0.5 µm 0.02 Mil
Display resolution
0.1 µm 0.004 Mil 0.1 µm 0.004 Mil 0.1 µm 0.004 Mil 0.1 µm 0.004 Mil 0.1 µm 0.004 Mil 0.1 µm 0.004 Mil
Laser scan rate
Laser scan velocity
400 scans/s
400 scans/s
400 scans/s
400 scans/s
400 scans/s
63 m/s 206.7'
63 m/s 206.7'
63 m/s 206.7'
63 m/s 206.7'
63 m/s 206.7'
Laser scan range
400 scans/s
126 m/s 413.4'
Approx. 65 mm
2.56"
Approx. 33 mm 1.30"
Main display: 7-segment green LED (8 digits)
Sub display: 16 character x 2 line LCD (Backlight color: yellow-green)
Measured value
Minimum display unit
0.1 µm 0.004 Mil /0.2 µm 0.008 Mil
Display range
-999.9999 to 9999.9999
Target position indicator
Green LED (7 levels)
Comparator output indicator
Green LED x 3 (HI/GO/LO)
Laser emission indicator
Green LED x 2 (HEAD 1/ HEAD 2)
Hold synchronous, LASER REMOTE, PROGRAM SELECT (Program Nos. 1 to 5)
Control I/O
Non-voltage input (contact/solid state)
Analog voltage
±6 V, Output impedance: 0 Ω
Contact output
Relay output: 3PST-NO contact, 250 VAC, 2 A (resistive load)
Control input
36-pin
connector
I/O
Control
7-level/3-level
output
Hold synchronous, AUTO ZERO SET/ RESET, PROGRAM SELECT (Program Nos. 1 to 5)
TTL level, negative logic
40 mA max. (30 V max.)
Interface port
RS-232C/GP-IB (optional)/ BCD (optional)
Power supply
85 to 264 VAC, 50/60 Hz
Power consumption
40 VA max.
40 VA max.
40 VA max.
40 VA max.
40 VA max.
40 VA max.
Ambient
temperature
0 to +45°C
0 to +45°C
0 to +45°C
0 to +45°C
0 to +40°C
0 to +40°C
0 to +40°C
0 to +40°C
0 to +40°C
0 to +40°C
0 to +40°C
0 to +40°C
0.8 kg
T: 0.5 kg
R: 0.4 kg
0.8 kg
T: 0.5 kg
R: 0.4 kg
0.8 kg
Approx. 2.5 kg
(base included)
Weight
Scanning head
Controller
Scanning head
Controller
4.
Approx. 4.6 kg
1. When the outer diameter is measured.
2. When a rod 10 mm 0.39" in diameter is measured in a 2 x 20 mm 0.08" x 0.79", 4 x 20 mm 0.16" x 0.79", or 10 x 20 mm 0.39" x 0.79" measuring area.
3. When measuring a rod 20 mm 0.79" in diameter in a 20 x 40 mm 0.79" x 1.57" measuring area.
4. ‘T’ indicates a transmitter, ‘R’ indicates a receiver.
429
MAIN MENU
PRODUCTS
APPLICATIONS
INDEX
SELECTION GUIDE
LS-3100 Multi-functional Laser Scan Micrometers
Functions
Four segment modes
Four measurement modes
Targets placed within the measuring area interrupt the
laser beam, thus creating light and dark regions. The
border between the light and dark regions is referred to as
an “edge”. Also, each dark or light region is called a
“segment”.
From the following four measurement modes, the desired
mode can be selected and set by simply pressing a key.
GAP
DIA.
EDGE 2
EDGE # 1
EDGE # 2
EDGE # 3
EDGE # 4
EDGE # 5 (X-1)
EDGE # 6 (X)
1. DIA
This mode is used for outer diameter measurements.
When there is only one target in the measuring area, its
outer diameter is measured. When there are two or
more targets, the distance between the upper edge of
the uppermost target and the lower edge of the lowermost target is measured. In the figure above, the
distance between EDGE #2 and EDGE #5(X-1) is
measured.
2. EDGE 1
The width of the uppermost region where the laser
beam is not interrupted is measured. This mode is for
target displacement measurement. In the figure above,
the distance between EDGE #1 and EDGE #2 is
measured.
• P-P (PEAK to PEAK) ..... (a)
The difference between the maximum (peak) and minimum (bottom) values measured during a specified period
is displayed and output.
• PEAK (PEAK HOLD) ..... (b)
The maximum value measured during a specified period
is displayed and output.
• BOTTOM (BOTTOM HOLD) ..... (c)
The minimum value measured during a specified period is
displayed and output.
Measurement value
EDGE 1
DIA.
• NORMAL
Measured value is displayed or output as is.
(a)
(b)
(c)
t
Calculation function
3. EDGE 2
The width of the lowermost region where the laser
beam is not interrupted is measured. In the figure
above, the distance between EDGE #5(X-1) and EDGE
#6(X) is measured.
By substituting two measured values obtained by simultaneous 2-point measurement for X and Y, various calculations can be performed. The following eight calculation
modes are available;
X- Y
X +Y
, (5)
,
2
2
X +Y
)
2
(1) X & Y, (2) X + Y, (3) X - Y, (4)
4. SEG (m, n)
The distance between two specified edges is measured.
Respectively for “m” and “n”, a number between 1 and
126 can be specified.
(6) -X & -Y, (7) -(X + Y), (8) - (
Example: Measuring the average of X/Y axes of wire
Example: In the figure below, if SEG (5, 6) is specified,
the diameter of IC lead (c) is measured. If SEG (6, 7) is
specified, the distance between leads (c) and (d) is
measured.
1 2
(a)
3
(b)
4
5 6
(c)
7
(d)
8
9 10
(e)
Measurement of IC lead pitch
11 12
(f)
(
X+ Y
)
2
By mounting two scanning
heads at right angles as
shown on the right, the X and
Y axes diameters can be
measured on the same level.
Y
Measurement of (X + Y)
Example: Measuring sheet thickness using a roller (X - Y)
By measuring the distance to
the roller surface and to the
sheet surface, the difference
between the values can be
calculated and the sheet
thickness is obtained.
430
X
X
Y
Measurement of sheet thickness
MAIN MENU
PRODUCTS
APPLICATIONS
INDEX
SELECTION GUIDE
Multi-functional Laser Scan Micrometers
Example: Measuring the outer diameter of a pipe of 60
mm 2.36" or bigger in diameter. [-(X + Y)]
By subtracting X (the distance to the
upper end of the pipe) and Y (the
distance to the lower end of the
pipe) from the distance between the
upper and lower ends of the two
scanning heads’ measuring areas
(offset value), the diameter of the
pipe can be obtained.
X
Y
Measurement of large
target diameter
Versatile functions for control and protection
Storage of settings
Up to 10 different tolerance or parameter settings can be
stored. Even when the target type is changed, these
settings can be called up to match target type by simply
pressing a key.
3-level/7-level comparator
The measured value is
compared to the preset
upper and lower limits and
the comparison result is
output in 3 levels, HIGH,
GO, or LOW. And, the corresponding LED (HIGH, GO, or
LOW) lights according to the result. This comparator
output is sent through the RS-232C interface, analog
outputs, and relays (comparator output terminals). 7-level
comparator output can be accessed using the control I/O.
3-level comparator
Upper limit 3
HIGH2
Upper limit
GO
LOW
Offset
By adding an offset value to the measured value, the
measured value can be changed to the desired reference
value.
7-level comparator
HIGH3
HIGH
Upper limit 2
HIGH1
GO
Lower limit
Analog voltage output scaling
Measured values are converted into an analog voltage
between -6 V and +6 V as desired. By properly matching
the measuring range and the voltage range above, even a
minute change in measured values can be monitored at a
high accuracy without being affected by noise interference.
LS-3100
Upper limit 1
Lower limit 1
LOW1
Lower limit 2
LOW2
Lower limit 3
LOW3
Parameter lock
Various measurement parameters can be locked to
prevent inadvertent alterations.
Display unit selectable
The display can be set to display values in millimeters or
inches with just the touch of a key.
Auto-zero
The value displayed on the front panel can quickly be set
to “0.0000” with just the touch of a key.
Output hold
The displayed value and output value can be retained with
just the touch of a key. Use this function to read the
measured value directly from the display or confirm the
measured value after a measurement.
431
MAIN MENU
PRODUCTS
APPLICATIONS
INDEX
SELECTION GUIDE
LS-3100 Multi-functional Laser Scan Micrometers
Part Names and Functions
Front Panel
Rear Panel
2
1
3
4
5
6
25 26
27
31
32
28
29
30
LIMIT
LS-3100
LASER
1
LASER
2
OFF SET ZERO HOLD LOCK POSITION
LASER SCAN DIAMETER
ON
OFF
POWER
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
SEG
MODE
SET
7
8
9
ZERO
AVE
LIMIT
OFS
4
5
6
HOLD
PRM
FNC
CAL
1
2
3
CLR
PROG
DISP
+/-
ENT
0
21
22
23
24
8 9 10 11 12 13 14 15 16 17 18 19 20
Laser emission indicator LED
Comparator output LEDs
Current setting indicator
Main display (CH1)
Target position indicator
Sub-display (CH2)
Key-operated power switch
SEGMENT key
AVERAGE key (for number of measurements)
PARAMETER key
PROGRAM key
MODE key
LIMIT key (for 3-level comparator output)
FUNCTION key
DISPLAY key
UP/DOWN key
CALIBRATION key
OFFSET key
SET key
Numeric keys
AUTO ZERO key
HOLD key
CLEAR key
ENTER key
25
26
27
28
29
30
31
32
33
34
35
36
37
38
33
34
35
36
37 38
SCANNING HEAD connector
SCANNING HEAD connector (when 2 are installed)
RS-232C connector
Expansion I/O port (used when option board is
installed)
36-pin connector (Control I/O)
Cooling fan
Analog voltage output terminals
Hold synchronous input terminals
Program selection input terminals
Laser emission control input terminals
Comparator limit output terminals
Frame ground terminal
Power supply connector
Fuse holder (2 A)
Connections
Interfaces
Interfaces enable the LS-3100 Series to connect to
external equipment. This enables systems such as a
comprehensive data management system to be created.
• GP-IB (optional)
Accommodates up to 15 physical devices in a system,
simplifying large-scale integration.
• BCD output (optional)
Interfaces to a printer or programmable logic controller to
perform high-speed data processing.
LS-3100
RS-232C
GP-IB
(optional)
BCD
(optional)
Analog
voltage
output
Control
I/O
• RS-232C
For communication with a computer, data transfer, and
remote setting of parameters.
432
• Analog voltage output
Provides analog voltage output in proportion to measurements for high-speed data analysis. The scaling function
adjusts the analog output to the level appropriate to the
desired measuring range, ensuring accurate monitoring of
fine differences in measuring data.
• Control I/O
A 3-level or 7-level tolerance range is standard for all
models. This feature also enables remote operation of
such functions as program change and auto-zero setting.
MAIN MENU
PRODUCTS
APPLICATIONS
INDEX
SELECTION GUIDE
Multi-functional Laser Scan Micrometers
RS-232C interface (equipped as standard)
Analog voltage output terminals
Enables communication with a computer, data transfer,
and remote setting.
Outputs analog voltage in proportion to measurement.
± 6 V ±120 mm 4.72" to ± 6 V ± 0.012 mm 0.0007"
(output impedance: 0 Ω, current capacity: 10 mA)
Conforms to EIA (Electronic Industries Association)
RS-232C.
Control I/O
Communication parameters
Full
Start-stop
ASCII
8 bits
1 bit
None
Duplex
Synchronization
Data format
Data length
Stop bit length
Parity check
Baud rate
75/150/300/600/1200/2400/4800/9600/19200 bps
Output
• TTL open-collector
(7406 equivalent)
• Maximum applied
voltage: 30 V
• Maximum sink current:
40 mA
Input
• TTL level, negative logic
(74LS19 equivalent)
+5 V
IC
OUT
GP-IB interface (optional)
3 kΩ
Accommodates up to 15 physical devices in a system.
Conforms to IEEE standard 488-1978.
Data format
Number of
15 max. (including controller)
connectable devices
20 m 65.6' max.
Total cable length
Cable length between
4 mm 0.16" max.
devices
6.2 k Ω
Terminal block I/O
Control input
Input circuit
Example of connection
Contact input
+12 V
BCD I/O interface (optional)
Output
TTL level, positive logic
(74LS04 equivalent)
photocoupler
1.8 k Ω
Control input
terminal
GND
Controller
Input
680Ω
TTL level, negative logic
(74LS19 equivalent)
Control input
terminal
GND
Solid-state (transistor) input
Controller
OUT
3 kΩ
Open-controller
output
Control input
terminal
GND
Controller
+5 V
IC
IC
IN
ASCII
Logic 0 "High" condition: +2.4 V min.
Logic 1 "Low" condition: +0.4 V max.
(2-way transceiver used)
Logic level
LS-3100
IC
IN
Control output
HIGH, LOW, GO output
Relay contact 3PST-NO, 250 VAC 2 A (resistive load)
6.2 k Ω
Characteristics
Measuring area vs. accuracy (typical example)
LS-3032
Center of detecting area
Transmitter
0.39" 10
0.16" 4
Receiver
LS-3033/LS-3033SO(8073)
Transmitter
1.18"
30 20
30 20
1.18"
0.79"
±2 µm 0.08 Mil
When a rod 10 mm 0.39" in diameter is measured.
(reference temperature: 20°C)
Drift
0°C
10°C
+2.2 µm +1.1 µm
+0.09 Mil +0.04 Mil
20°C
0
30°C
-1.4µm
-0.06 Mil
40°C
-3.2 µm
-0.13 Mil
±2 µm 0.08 Mil
0.79"
60
2.36"
±5 µm 0.20 Mil
Temperature
Center of detecting area
0.39"(0.20") 20 (5)
0.39"(0.08") 10 (2)
±5 µm 0.20 Mil
When a rod 10 mm 0.39" in diameter is measured with
a transmitter-to-receiver distance set to 120 mm 4.72".
(reference temperature: 20°C)
Temperature
Drift
0°C
10°C
+2.6 µm +1.3 µm
+0.10 Mil +0.05 Mil
20°C
0
30°C
-1.4 µm
-0.06 Mil
40°C
-3.2 µm
-0.13 Mil
433
MAIN MENU
PRODUCTS
APPLICATIONS
INDEX
SELECTION GUIDE
LS-3100 Multi-functional Laser Scan Micrometers
LS-3034
Center of detecting area
5 0.20"
2 0.08"
Transmitter
LS-3036
Center of detecting area
Receiver
10 0.39"
4 0.16"
Transmitter
Receiver
30 20
1.18" 0.79"
30 20
1.18"
±2 µm 0.08 Mil
0.79"
±2 µm 0.08 Mil
±5 µm 0.20 Mil
When a rod 10 mm 0.39" in diameter is measured.
(reference temperature: 20°C)
Temperature
Drift
0°C
10°C
+2.6 µm +1.3 µm
+0.10 Mil +0.05 Mil
20°C
0
30°C
-1.4 µm
-0.06 Mil
40°C
-3.2 µm
-0.13 Mil
±5 µm 0.20 Mil
When a rod 10 mm 0.39" in diameter is measured.
(reference temperature: 20°C)
Temperature
Drift
0°C
10°C
+3.7 µm +1.7 µm
+0.15 Mil +0.07 Mil
20°C
0
30°C
-1.7 µm
-0.07 Mil
40°C
-3.5 µm
-0.14 Mil
100
3.94"
LS-3060
1.57"
Transmitter
40 60 2.36"
60 2.36"
20
0.79"
30
1.18"
± 3 µm 0.12 Mil
± 6 µm 0.24 Mil
When a rod 20 mm 0.79" in diameter is measured.
(reference temperature: 20°C)
Temperature
Drift
0°C
10°C
+8.6 µm +4.3 µm
+0.34 Mil +0.17 Mil
20°C
0
30°C
-4.2 µm
-0.17 Mil
40°C
-8.4 µm
-0.34 Mil
Hints on Correct Use
Detectable objects
Compatibility
Different target shapes and luster can sometimes produce
measurement errors. To correct this, measure a known
target and use the calibration key.
Controllers and scanning heads, and transmitters and
receivers are calibrated as pairs. Therefore, to meet
specifications, combine units having the same serial
number.
Measuring conditions
When the target is vibrating, the measured value will
fluctuate. To attain accurate measurement, average a
greater number of measurements.
Connecting to a computer
When connecting the LS-3100 controller to a computer,
use a standard RS-232C connecting cable.
Warning
The LS-3100 Series conforms to FDA and IEC standards
as follows:
Model
FDA
IEC
434
LS-3034
LS-3033
SO
LS-3032 LS-3033 LS-3036 LS-3060
(8073)
Class I
Class II
Class 1
FDA Class II
CAUTION
LASER RADIATION-DO NOT
STARE INTO BEAM
SEMICONDUCTOR LASER 670nm
MAXIMUM OUTPUT 0.5mW
CLASS II LASER PRODUCT
IEC Class 1
CLASS1 LASER PRODUCT
MAIN MENU
PRODUCTS
APPLICATIONS
INDEX
SELECTION GUIDE
Multi-functional Laser Scan Micrometers
LS-3100
Dimensions
Unit: mm
Scanning head
LS-3060
ø0.18"
4 x ø4.5 through-hole
ø8 spot facing, 4.5 (d)
ø0.31"
0.18"
0.59"
15
M4
42
1.65"
22 0.87"
2.58"
65.5
27 1.06"
1.18" 1.34"
30 34
2.58"
65.5
10 0.39"
1.34" 1.18"
34 30
7.11"
180.5
2.36"
98.5
3 x ø5.5 Mounting hole
ø0.22"
3 x ø5.5 Mounting hole
Measuring area
ø0.22"
110 98.5
4.33" 3.88"
60
2.36"
33
1.30"
0.24" 6
3.94"
100
7.87"(±1.97")
200 (±50)
0.31" 8
21
0.83"
167
6.57"
77
3.03"
0.94"
24
110
4.33"
98.5
3.88"
60
6
0.24"
216 (±50)
8.50"(±1.97")
62
2.44"
20
0.79"
1.69"
43
21
0.83"
85
3.35"
0.20"
5
4 x M4
5 0.20"
32 1.26"
1.26" 32
220.5
8.68"
(0.28") (7)
0.47"
12
138.5
5.45"
479
18.86"
(7) (0.28")
4 x M4
4 x M4
12 0.47"
18 0.71"
18
0.71"
152
5.98"
LS-3032/3034/3036
Inch
115.5
4.55"
115.5
4.55"
70
2.76"
(12) (0.47")
38
1.50" 26
1.02"
Measuring area
4 x ø5.5 ø0.22"
mounting hole
(34) (30)
(1.34) (1.18)
72
83 2.83"
3.27"
56
2.20"
32
1.26"
6
0.24"
4.88"
124
0.20" 5
LS-3033/3033SO(8073)
30
1.18"
60
2.36"
19.5
0.77"
8.27"
210
220
8.66"
(7) (0.28")
12.5 0.49"
12.5 0.49"
38
1.50"
38
1.50"(25.5)
(1.00")
(1.18") (1.34")
(30) (34)
4.15"
105.5
4.15"
105.5
(25.5) (1.00")
4 x ø4.5 ø0.18"
mounting hole
4 x ø4.5 ø0.18"
mounting hole
Measuring area
Transmitter
51
2.00"
Receiver
73.5
2.89" 85
3.35"
46
1.81"
85 73.5
3.35" 2.89"46
1.81"
6
0.24"
0.31 8
3.62"
92
2.36"
60
4.72"(±1.57")
120 (± 40)
136 (± 40) 5.35"(±1.57")
331 (± 40) 13.03" (±1.57")
3.62"
92
(34) (30)
(1.34") (1.18")
(7) (0.28")
24
0.94"
30
1.18"
6
0.24"
435
MAIN MENU
PRODUCTS
APPLICATIONS
INDEX
SELECTION GUIDE
LS-3100 Multi-functional Laser Scan Micrometers
Unit: mm Inch
Connecting cable (3 m 9.8' long*, standard)
Scanning head mounting bracket (standard)
(for LS-3032/3033/
(for LS-3060)
3033SO(8073)/3034)
2 x ø 4.5 ø0.18"
ø0.61"
ø15.5
2 x ø 4.5
ø0.18"
22
0.87"
12
0.47"
6
0.24"
2 x ø 4.4 ø0.17"
12
0.47"
0.47"
12
6
18
0.71" 0.24"
24
0.94"
ø6, Cable length : 3 m 9.8'
ø0.24"
34
1.34"
2 x ø 4.4 ø0.17"
12
46
1.81"
t = 1.6
0.06"
0.71" 18
0.94" 24
6 0.47"
0.24"
1.65"
42
t = 1.6 0.06"
Controller
LS-3100 (LS-3100D)
R11
0.43"
330
12.99"
R7.5
0.30"
244
9.61"
230
9.06"
123 111
4.84" 4.37"
ø0.79"
ø 20
0.51"
13
122
4.80"
25
1.42"
36
436
0.98"
Approx. 47
1.85"
238
9.37"
ø0.61"
ø15.5
* For connecting the controller and scanning
head.
For connecting the transmitter and receiver.
LS-3033/3033SO (8073): 3 m 9.8'
LS-3060: 0.7 m 2.3'
22
0.87"
0.24"
6
34
1.34"
20 0.79"
1.34" 34
176
6.93"
ø16
ø0.63"
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising