Eclipse ThermJet Burners
Datasheet 205-9
2/11/2013
Eclipse ThermJet
Burners
Model TJ0500
Version 2.7
Parameter
Burner Velocity
Model TJ0500
Maximum Input, Btu/h (kW)
Medium & High Velocity
5,000,000 (1465)
Minimum Input On-Ratio, Btu/h (kW)
Medium & High Velocity
500,000 (146)
Medium & High Velocity
100,000 (29)
Minimum Input Fixed Air, Btu/h (kW)
Gas Inlet Pressure Required, "w.c. (mbar)
Tap B (see page 3)
High Velocity
Medium Velocity
Air Inlet Pressure Required, "w.c. (mbar)
15% Excess Air at Maximum Input
Tap A (see page 3)
High Velocity
Medium Velocity
High Fire Flame Length, inches (mm)
Measured from the outlet end of the combustor
High Velocity
Medium Velocity
Approximate Flame Velocity, ft/s (m/s)
15% Excess Air at Maximum Input
Maximum Combustion Air Temperature
Flame Detection
Fuel
For any other mixed gas, contact Eclipse, Inc.
Natural Gas
13.5 (34.0)
Propane
14.0 (35.0)
Butane
13.0 (33.0)
Natural Gas
5.5 (14.0)
Propane
6.0 (15.0)
Butane
5.5 (14.0)
Natural Gas
18.5 (46.0)
Propane
17.5 (44.0)
Butane
17.5 (44.0)
Natural Gas
10.0 (25.0)
Propane
10.0 (25.0)
Butane
10.0 (25.0)
Natural Gas
75 (1900)
Propane
90 (2285)
Butane
85 (2160)
Natural Gas
100 (2550)
Propane
100 (2550)
Butane
105 (2670)
High Velocity
580 (177)
Medium Velocity
280 (85)
300°F (149°C). For higher temperatures use TJPCA (Datasheet 206)
UV scanners can be used with all combustors.
Natural gas, propane or butane1
Approvals
1. See Design Guide 205 for more information about typical fuel composition and properties
• All information is based on laboratory testing in neutral (0 "w.c., 0 mbar) pressure chamber. Different chamber conditions may affect
the data.
• All information is based on standard combustor design. Changes in combustor will alter performance and pressures.
• All inputs based upon gross calorific values and standard conditions; 1 atmosphere, 70°F (21°C).
• Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust
earlier supplies accordingly.
• Plumbing of air and gas will affect accuracy of orifice readings. All information is based on generally
acceptable air and gas piping practices.
Performance Graphs
NOX
Ignition & Operational Zones
(High Velocity Combustor)
120
10,000
100
NOX ppm (@ 3% O2)
% Excess Air
Ignition and
Operational Zone
1,000
100
80
60
40
20
10
NOX X Natural Gas
NOX X Propane/Butane
0
0
1,000
0
300
2,000
3,000
Input (x 1,000 Btu/h)
600
900
Input (kW)
4,000
0
5,000
1,200
1,000
2,000
3,000
4,000
5,000
Input (x 1,000 Btu/h)
0
1,500
300
600
900
1,200
1,500
Input (kW)
Emission correction factor for medium velocity combustor
is 1.20. Emissions data based on, on-ratio control firing at 15%
excess air corrected to 3% O2.
Emissions from the burner are influenced by:
• Fuel type
• Combustion air temperature
• Firing rate
• Chamber conditions
• Percent of excess air
For estimates of other emissions, contact Eclipse.
Air Orifice ∆P vs. Input
Fuel Orifice ∆P vs. Input
4
3
2
2.5
1
0.0
0
0
0
2
∆P (mbar ± 5%)
5.0
∆P ("w.c. ± 5%)
∆P (mbar ± 5%)
7.5
Natural Gas - 37 mm orifice
Propane - 29 mm orifice
Butane - 29 mm orifice
1,000
300
2,000
3,000
Input (x 1,000 Btu/h)
600
900
Input (kW)
4,000
5,000
15.0
6
12.5
5
10.0
7.5
∆P ("w.c. ± 5%)
5
12.5
10.0
(∆P Measured Between Taps B and D)
(∆P Measured Between Taps A and C)
15% Excess Air at Maximum Input
Air Orifice (125 mm)
4
3
5.0
2
2.5
1
0.0
0
0
1,000
2,000
3,000
4,000
5,000
Input (x 1,000 Btu/h)
1,200
1,500
0
300
600
900
Input (kW)
1,200
1,500
Eclipse ThermJet TJ0500, V2.7, Datasheet 205-9, 2/11/2013
Dimensions and Specifications
Dimensions in mm (inches)
Burner Housing
347
(13.7)
10 (0.4)
Ø340
(13.4)
4 x Ø12 (0.5)
Ø300
(11.8)
Spark Plug
M14
161
(6.3)
1/2" NPT
UV Scanner
Adapter
260
(10.2)
2" NPT or BSP
Fuel Inlet
6" welded
Pipe Connection
Air Inlet
(165 O/D)
175
(6.9)
331
(13.0)
Burner weight less combustor: 93 lbs (42 kg)
Tap Locations
Tap C
Tap A
Tap D
Tap B
Eclipse ThermJet TJ0500, V2.7, Datasheet 205-9, 2/11/2013
3
Dimensions and Specifications
Dimensions in mm (inches)
Combustors
Ø340
(13.4)
6.4
(0.3)
4 x Ø12 (0.5)
Alloy Combustor (AISI 310)
Weight: 14.5 lbs (6.6 kg)
Maximum Chamber Temp: 1,750°F (950°C)
Ø254
(10)
395
(15.6)
Ø300 (11.8)
334
(13.2)
390
(15.4)
Refractory Combustor with AISI 330 wrapper
Weight: 160 lbs (73 kg)
Maximum Chamber Temp: 2,800°F (1,535°C)
165 (6.5)
394
(15.5)
6
(0.2)
440
(17.3)
4 x Ø14 (0.6)
Exhaust Outlet Diameter:
High Velocity: Ø125 (4.9)
Medium Velocity : Ø177 (7.0)
8 x Ø14 (0.6)
Ø450
(17.7)
Ø320
(12.6)
10
(0.4)
343
(13.5)
394
(15.5)
Datasheet 205-9, 2/11/2013
Ø393
(15.5)
Down Firing Block with AISI 330 wrapper
Weight: 185 lbs (83.9 kg)
Maximum Chamber Temp: 2,800°F (1,535°C)
Ø500