Catalogues and Brochures ICC PRODUCT

Catalogues and Brochures ICC PRODUCT
MANUFACTURER OF PREMIUM CHIMNEY SYSTEMS
FOR PROFESSIONAL INSTALLERS
PRODUCT
CATALOG
2015-2016
Table of Contents
GENERAL INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
THE KEY TO OUR SUCCESS. . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LIST OF NEW AND UPDATED PARTS . . . . . . . . . . . . . . . . . . 3
WARRANTY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
EXCEL
Technical Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Allowable Flue Gas Temperatures. . . . . . . . . . . . . . . . . 6
Clearance to Combustible Materials. . . . . . . . . . . . . . . 6
Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Typical Installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Product Descriptions and Dimensions . . . . . . . . . . . 8 - 15
Canadian Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Offset Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
ULTRABlack
Technical Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Allowable Flue Gas Temperatures. . . . . . . . . . . . . . . . 18
Clearance to Combustible Materials. . . . . . . . . . . . . . 18
Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Engineering and Design Considerations. . . . . . . . . . . . . 18
Product Descriptions and Dimensions . . . . . . . . . . 19 - 21
Offset Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 - 23
EXCELPrime
Technical Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Allowable Flue Gas Temperatures. . . . . . . . . . . . . . . . 26
Clearance to Combustible Materials. . . . . . . . . . . . . . 26
Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Engineering and Design Considerations. . . . . . . . . . . . . 26
Product Descriptions and Dimensions . . . . . . . . . . 27 - 30
EXCELiner
Technical Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Allowable Flue Gas Temperatures. . . . . . . . . . . . . . . . 32
Clearance to Combustible Materials. . . . . . . . . . . . . . 32
Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Engineering and Design Considerations. . . . . . . . . . . . . 32
Product Descriptions and Dimensions . . . . . . . . . . 33 - 36
Model RIS
Technical Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Allowable Flue Gas Temperatures. . . . . . . . . . . . . . . . 38
Clearance to Combustible Materials. . . . . . . . . . . . . . 38
Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Product Descriptions and Dimensions . . . . . . . . . . 39 - 42
Offset Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
EXCELPellet
Technical Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Allowable Flue Gas Temperatures. . . . . . . . . . . . . . . . 44
Clearance to Combustible Materials. . . . . . . . . . . . . . 44
Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Engineering and Design Considerations. . . . . . . . . . . . . 44
Typical Installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Product Descriptions and Dimensions . . . . . . . . . . 46 - 54
Offset Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
EXCELDirect®
Technical Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Clearance to Combustible Materials. . . . . . . . . . . . . . 56
Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Sizes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Design Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Typical Installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Product Descriptions and Dimensions . . . . . . . . . . 58 - 67
Offset Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
OPEN FIREPLACE CHIMNEY
DESIGN CONSIDERATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . 69
Chimney Sizing and Flue Height. . . . . . . . . . . . . . . . . . . . 69
Sizing Fireplace Chimneys. . . . . . . . . . . . . . . . . . . . . . . . . 69
CHIMNEY HEIGHT DESIGN CONSIDERATIONS. . . . . . . . . 70
Recommended Flue Height. . . . . . . . . . . . . . . . . . . . . . . . 70
INDEX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 - 72
OTHER PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
General Information
1
General Information
Industrial Chimney Company was established in 1991
by a small group of partners with over 75 years combined experience in the chimney industry. Our experience convinced us that the needs of our ultimate
customers (the people who live in a house with one of
our chimneys) are served best when our products are
sold by retailers who specialize in chimney and fireplaces. Specialty dealers understand the unique nature
of our industry and are qualified to provide both technical support and installation. One of the cornerstones of
our business is the conviction that hearth dealers are
our essential partners in delivering the highest quality, safest chimney systems available.
From the beginning our objective has been to engineer products which enable better, faster installations
while using fewer parts; improving installation efficiency.
This is the best way we know of to insure that consumers benefit from safer installations and competitive
pricing. Our goal is to do everything possible to help
our business partners do the best installation possible
for the homeowner.
We believe that our long term accomplishments are tied
to our commitment to people, both inside and outside
our company. While we are continuously investing in
our plant and processes, the most gratifying returns
come from investments in people. Our greatest sense
of accomplishment comes when we see an employee
or customer achieve their personal or business goals.
That’s why we continue to make major commitments
in promotion and funding of hearth industry education.
We focus our efforts in four areas. We manufacture residential venting, specifically insulated chimneys, single
& double walled stove pipe and chimney liner for wood
burning applications as well as venting products for pellet and gas appliances. We also manufacture the most
complete line of high-efficiency, clean-burning fireplaces
on the market. Most recently we’ve begun manufacturing clean-burning open fireplaces, a rapidly-growing
new category. In addition we manufacture commercial/
industrial venting - everything from chimney liners to
48" diameter pressure stacks, which we sell through specialty reps in that market. Since the beginning, our residential, commercial, and industrial venting products have
enabled us to secure leadership roles in each segment of
the industry.
Thanks to the strong support we have received from our
distributors and dealers our strategy is working. We have
grown dramatically over the last years. Our 90,000 ft²
factory runs 24 hours a day, twelve months a year. It is
situated on over 20 acres of prime industrial property
and is filled with state of the art machinery, and we employ
about 200 people.
This catalog contains information on our residential venting products and we have done our best to insure it is
complete and up to date. If you have any questions or
concerns regarding any of our products please feel free to
contact us directly. We will be pleased to assist you.
The ICC team
2
The Key to Our Success
THE KEY TO OUR SUCCESS
IS OUR PEOPLE
Making great, innovative products requires great, innovative minds. It is easy to look at a competing product and
reproduce it; but everything we do at ICC is the result of
time, testing and engineering. We will make 50 different
versions of one part, to make sure it satisfies the customer
purchasing it and the dealer installing it.
We occasionally glance at our competitors catalogs, only
to find our components in their product lines. That’s fine,
because while they’re looking at our backs, we’re looking forward with ideas and designs they haven’t even
dreamed of.
ICC’s laboratory is DAP certified by UL, permitting
us to test our new ideas without having to book
independent lab time. This gives us freedom to be
more creative and revolutionary.
List of New and Updated Parts
LIST OF NEW
AND UPDATED PARTS
NEW PARTS
REDESIGNED PARTS
EXCEL
EXCEL
Hardware Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Roof Brace Stiffener. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
EXCELPellet
ULTRABlack
Masonry Thimble Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . 21
EXCELPrime
EXCELiner
Flex Liner Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Offset Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
EXCELPellet
47
47
50
50
51
53
53
53
EXCELDirect®
Slip Elbow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Universal Flashing for IVT . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clay Tile Flashing for IVT . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Prefab Chimney Top Adapter . . . . . . . . . . . . . . . . . . . . . . . .
Universal Flashing for Traditional Cap. . . . . . . . . . . . . . . . .
Clay Tile Flashing for Traditional Cap . . . . . . . . . . . . . . . . .
Hose Clamp Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wind / Rain Shield. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flex Liner Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Insulated Wall Thimble. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Traditional Masonry Adapter Cap . . . . . . . . . . . . . . . . . . . . 53
EXCELDirect®
12" Slip Flue Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Tee Cap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Slip Elbow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type A Chimney Reline Adapter . . . . . . . . . . . . . . . . . . . . .
Female Flex Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Harman Style Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Universal Flashing for Traditional Cap. . . . . . . . . . . . . . . . .
Clay Tile Flashing for Traditional Cap . . . . . . . . . . . . . . . . .
Hose Clamp Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Roof Radiation Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
59
62
62
63
63
63
64
64
66
Insert Vertical Termination . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Traditional Co-Linear Chimney Cap. . . . . . . . . . . . . . . . . . . 63
Traditional Masonry Adapter Cap . . . . . . . . . . . . . . . . . . . . 67
3
4
Limited Lifetime Warranty
LIMITED LIFETIME WARRANTY
FOR ICC VENTING PRODUCTS
Industrial Chimney Company (ICC) warrants all its venting
products to be free from functional failure due to defects in
material or workmanship for as long as the original consumer
owns the chimney system (5 years only for EXCELPrime).
This warranty provides for replacement of any components
which fail as a result of normal use and includes replacement
of any components damaged as a result of a chimney
fire. (Note: Chimney fires are dangerous and preventable.
We strongly encourage you to have your chimney cleaned
regularly.) ICC warrants all stainless steel chimney
components against perforation as a result of corrosion.
This warranty does not cover damage caused to the building
by chimney fires or misuse of the product.
No claims under this warranty will be honored unless
ICC is notified of the potential claim and is given the
opportunity to have one of its agents examine the chimney
prior to replacement.
ICC will only be responsible for repair or replacement of
any components found to be defective under this warranty.
In no event shall ICC be responsible for any incidental or
consequential damage caused by defects.
ICC will not be responsible for labor of any kind required in
the removal or replacement of any system replaced under
this warranty.
Each venting product is designed to vent specific fuels
only. This warranty is void if the venting is used in an
application for which it is not designed.
EXCEL, EXCELiner, EXCELPrime, RIS and ULTRABlack:
Continuous 650°C (1200°F) temperature
Fuel: Residential heating oil, untreated wood,
low sulphur coal and natural or LP gas
EXCELPellet:
Continuous 300°C (570°F)
Fuel: Wood pellet and agricultural products,
natural gas, propane and liquid fuel
EXCELDirect®:
Gas-Fired Direct Vent appliances certified
with EXCELDirect®
Fuel: Natural or LP gas
During the first ten years of the warranty (five years for
EXCELPellet & EXCELDirect), ICC will provide replacement
components except rain caps at no charge. During the
balance of the warranty ICC will provide replacement
chimney components at 50% of the current retail price
at the time of the warranty claim. This applies to all ICC
venting products except for ULTRABlack Double Wall
Stove Pipe and EXCEL Deluxe Rain Caps (EDRC), both of
which are covered 100% for life.
All ICC systems must be installed according to the Installation Instructions which are included with every system at the
time of purchase. If you do not have a set of installation instructions, they are available free upon request or online at:
http://icc-rsf.com/en/installation-instructions-excel-chimney-ultrablack-exceliner-excelpellet-ris
This warranty is void if the chimney is not installed according to the installation instructions.
This warranty may not be extended or modified by our agents or representatives.
This warranty is in lieu of all other express warranties or guarantees, of any kind.
EXCEL
ALL FUEL, INSULATED CHIMNEY SYSTEM 5" – 8"
6
Technical Information | EXCEL
EXCEL
EXCEL Technical Information
Certification
Allowable Flue Gas Temperatures
EXCEL is tested and listed by Intertek Testing Services
to two safety standards:
Max Continuous
650°C (1200°F)
Brief Forced Firing 925°C (1700°F)
Tested To
1150°C (2100°F)
UL 103HT - The standard for solid and liquid fuel chimneys
installed in the USA. Along with many other tests the UL
103HT Standard requires the chimney to withstand three
10 minute chimney fires at 2100°F (1150°C). Listing #5965
Clearance to Combustible Materials
ULC S-629 - The standard for solid and liquid fuel chimneys
installed in Canada. Along with many other tests the ULC
S-629 Standard requires the chimney to withstand three
30 minute chimney fires at 2100°F (1150°C). Listing #5965
2" clearance except in areas protected by factory-built
supports certified for reduced clearance. EXCEL round and
square supports permit the chimney to be installed with
approximately 1 inch of clearance - in the area shielded by
the support.
Applications
Construction
EXCEL chimney is suitable for use on appliances that burn:
Flue: .016" stainless steel
Casing: .016" stainless steel
Seam: Interior and exterior seams are continuous
seam welded
Insulation: Thermoplus continuous blanket
Wall thickness: 1"
Paint: All black EXCEL components are painted
with Forrest “Stove Bright” flat black paint
▪▪ Wood
▪▪ Oil
▪▪ Coal
▪▪ Gas
▪▪ Charcoal
It is specifically engineered for wood burning stoves,
fireplaces and residential furnaces.
EXCEL Dimensions and Support Capacities
Chimney size
5"
6"
7"
8"
Rough opening required
(INCHES)
Round support (ERDS)
10 x 10
10 x 10
11 x 11
12 x 12
Square support (ESS)
N/A
10 x 10
11 x 11
12 x 12
Roof support (ESR)
11 x 11
12 x 12
13 x 13
14 x 14
Offset support (EOS)
11 x 11
12 x 12
13 x 13
14 x 14
Radiation shield (ERS & ERSA)
11 x 11
12 x 12
13 x 13
14 x 14
Wall radiation shield (EWRS)
10 x 10
10 x 10
11 x 11
12 x 12
Maximum height per support
(FEET)
Round support (ERDS)
65
55
50
45
Square support (ESS)
N/A
55
50
45
Roof support (ESR)
65
55
50
45
Wall support (EWS)
50
44
37
35
Offset support (EOS)
35
30
27
25
Radiation shields must be used at all floor joist and ceiling areas
EXCEL has been tested and
listed to the UL 103HT and
ULC S-629 chimney standards
by INTERTEK.
Listing# 5965
Typical Installations | EXCEL7
EXCEL Typical Installations
NOTE: The following information is provided to assist you in selecting
the chimney components required for your installation. It is intended
to be a guideline only. These are not the installation instructions.
EXCEL
DELUXE RAIN CAP
ROOF BRACE
STORM COLLAR
DELUXE RAIN CAP
FLASHING
STORM COLLAR
FLASHING
STORM COLLAR
ROUND SUPPORT
FINISH TRIM
SQUARE SUPPORT
FLUE EXTENSION
FINISH TRIM
STORM COLLAR
RAIN CAP
FLUE EXTENSION
RAIN CAP WITH SPARK SCREEN
FLASHING
STORM COLLAR
RADIATION SHIELD
FLASHING
ROOF SUPPORT
OFFSET SUPPORT
WALL SUPPORT
STORM COLLAR
RADIATION SHIELD
(ATTIC RADIATION SHIELD IN CANADA)
WALL SUPPORT
RADIATION SHIELD TUBE
(REQUIRED IN CANADA ONLY)
WALL RADIATION SHIELD
FLUE EXTENSION
FINISH TRIM
FLUE EXTENSION
FINISH TRIM
8
Product Descriptions | EXCEL
EXCEL
EXCEL Product Descriptions
Insulated Lengths
(EL48, EL24, EL18, EL12, EL6)
EXCEL chimney lengths are available in 48", 24", 18", 12" & 6" lengths. To determine the installed
length deduct 1 1/2" from the overall length.
INCHES
Insulated Lengths
Inside diameter
5
Nominal
7
Outside of Bead 7 1/4
3.6
48
24
46 1/4
22 1/4
Outside diameter
Weight - lbs/foot
Nominal length
Installed length
Insulated Adjustable Lengths
(ELA18)
6
8
8 1/4
4.2
18
16 1/4
7
9
9 1/4
4.9
12
10 1/4
8
10
10 1/4
5.3
6
4 1/4
The most common applications for the adjustable length are: - Between elbows so that any required
centre-to-centre offset can be achieved. - When it is necessary to balance the chimney height so that
the caps line up for functional or aesthetic reasons. - When a specific horizontal offset is required. The
adjustable length must be installed above a straight chimney length. It will not adjust into an elbow
or tee. To determine the installed length deduct 1 1/2" from the overall length. To adjust the length,
remove the screws, slide the sections of the outer casing together to the desired length and cut away
the excess insulation. Do not cut the inner flue, it will slide inside the next chimney length.
INCHES
Insulated Adjustable Lengths
Nominal length
Installed length
Insulated Tees
(ETI)
18" ajustable
9 1/2 - 16 1/4
The insulated tee can be used on the interior or exterior of a building. The tee is designed to be
used in combination with a wall support assembly. The EXCEL tee cap has a handle on the bottom
to simplify removal for cleaning.
INCHES
Dimensions
Code
5ETI
6ETI
7ETI
8ETI
Chimney Top Damper
(ETD)
A
11 1/4
12 1/4
13 1/4
14 1/4
B
6 3/4
7 1/4
7 3/4
8 1/4
C
6 1/4
6 3/4
7 1/4
7 3/4
Adding this “Top Damper” to a system seals it right at the top of the chimney. The “Chimney Top
Damper” is placed directly below the cap and is designed to prevent any cold air infiltration into
the house through the chimney. It functions on a chain that hangs down to the firebox and comes
with 30’ of wire.
INCHES
Dimensions
Code
7ETD
8ETD
A
7
8
B
9
10
C
12
12
D
10 1/4
10 1/4
Product Descriptions | EXCEL9
Elbows
EXCEL 15° and 30°elbows are tested and listed to the UL 103HT and ULC S629 Standards.
EXCEL 45° elbows are certified to ULC S629 only.
INCHES
Dimensions
Code
5EE15
6EE15
7EE15
8EE15
5EE30
6EE30
7EE30
8EE30
A
1 7/8
1 7/8
2
2
2 3/8
2 1/2
2 5/8
2 3/4
5EE45
6EE45
7EE45
8EE45
2 7/8
3
3 1/4
3 1/2
B
2 7/8
2 7/8
3
3
3 3/8
3 1/2
3 5/8
3 3/4
Canada only
Wall supports - Wall Bands (EWS)
Extended Wall Supports (EWSE)
3 7/8
4
4 1/4
4 1/2
The wall support (EWS) is used to support a vertical chimney on a through-the-wall installation.
The EXCEL Wall Support installs on the first length of chimney above the tee, (not below the tee,
thus making it easier to fasten the support to framing, instead of into concrete). The Wall Support utilizes
the universal band to fit 6, 7, & 8 inch chimneys. It is designed to slide in and out to fit a variety of wall
profiles. The Wall Support is also used as a lateral support every 8 feet in height. The Extended Wall
Support (EWSE) will allow the chimney to pass by a 12" overhang. It often eliminates the need to either
offset a chimney around the overhang or cut and finish the soffit and fascia. One support is required every
8’, minimum of two per system. The Old Style Wall Support (EWS-R) is generally more complicated to
install than the EWS. However it simplifies installations on irregular surfaces like vinyl siding.
INCHES
EWS Dimensions (Fits 6", 7" & 8" chimney)
Code
EWS
EWS-R
A
7, 8, 9 or 10
8, 9 or 10
B
5
5
C
3 1/2
3 1/2
D
6
16
EWSE Dimensions (Fits 6", 7" & 8" chimney)
Old Style Wall support (EWS-R)
Roof Support
(ESR)
Extended Wall support (EWSE)
Code
EWSE
A
8, 9 or 10
B
12 1/4
C
6 1/2
D
13
The roof support is primarily used when it is difficult to use a round or square support in a cathedral
ceiling. It can also be used above an offset, or to provide additional support when the chimney height
exceeds the capacity of the primary support. The roof support utilizes a universal band, so that the
same support fits 6, 7, & 8 inch chimneys. It is made with adjustable brackets, which allow it to
adjust easily to any roof pitch.
INCHES
Dimensions (Fits 5", 6", 7" & 8" chimney)
Code
ESR
A
7, 8, 9 or 10
B
6
C
Fits flat - 24 / 12
EXCEL
(EE15, EE30 & EE45)
10 Product Descriptions | EXCEL
EXCEL
Round & Square Supports
(ERDS, ERDSI & ESS)
EXCEL’s ceiling supports are suitable for use on flat or sloping ceilings. They must project into the
room a minimum of 3 inches on a flat ceiling. For sloping ceilings, see the EXCEL installation manual.
These supports are designed to act as a combination of support and attic radiation shield. To use either
support as an attic radiation shield, simply close the open area at the top of the support (in the attic)
with a storm collar.
INCHES
Round Support Dimensions
RDTR
Code
5ERDS
6ERDS
7ERDS
8ERDS
A
5
6
7
8
Code
6ESS
7ESS
8ESS
A
6
7
8
B
10
10
11
12
C
24
24
24
24
D
14 1/4
14 1/4
15 3/4
17
Square Support Dimensions
SQTR
Support Extensions
B
10
11
12
C
24
24
24
D
14
15
16
E
12
12
12
Support extensions are available to facilitate installations on very steep pitched ceilings, or where
the chimney must project unusually far into the room. Both the round and square support extensions
are 24" long.
(ERDSE & ESSE)
24"
Pitched Trim Rings
If you are installing a round support on a sloping ceiling, you will require a pitched trim ring. Use
the following table to determine the correct trim ring for your installation. Pitched trim rings are not
available in 5" Ø. The finish trim which comes with the square support, is adjustable for any ceiling
pitch from flat to 24/12. Not available in 5" Ø.
(ERTA, B, C & ECTA, B, C)
INCHES
Pitched Trim Ring Dimensions
INS
UL
Use ERTA, B, C for pitched
trim on Round Support.
AT
ION
Use ECTA, B, C for pitched
trim on EXCEL lengths.
ERTA, B, C
INS
UL
ROUND SUPPORT
AT
ION
FLUE EXTENSION
Trim For
Code
A
B
C
Pitch Range
ERDS/ERDSI
6ERTA
9 13/16
10 1/8
18 1/2
0/12 - 4/12
ERDS/ERDSI
ERDS/ERDSI
ERDS/ERDSI
ERDS/ERDSI
ERDS/ERDSI
ERDS/ERDSI
ERDS/ERDSI
ERDS/ERDSI
EXCEL
EXCEL
EXCEL
EXCEL
EXCEL
EXCEL
EXCEL
EXCEL
EXCEL
7ERTA
8ERTA
6ERTB
7ERTB
8ERTB
6ERTC
7ERTC
8ERTC
6ECTA
7ECTA
8ECTA
6ECTB
7ECTB
8ECTB
6ECTC
7ECTC
8ECTC
10 13/16
11 13/16
9 13/16
10 13/16
11 13/16
9 13/16
10 13/16
11 13/16
8 1/16
9 1/16
10 1/16
8 1/16
9 1/16
10 1/16
8 1/16
9 1/16
10 1/16
11 3/16
12 1/4
11 3/8
12 1/2
13 5/8
13 7/8
15 1/4
16 11/16
8 3/8
9 3/8
10 7/16
9 5/16
10 1/2
11 5/8
11 3/8
12 13/16
14 1/4
18 1/2
18 1/2
18 1/2
18 1/2
18 1/2
18 1/2
21 1/4
21 1/4
16 3/8
17 3/8
18 1/2
17 3/8
18 1/2
19 5/8
19 3/8
20 7/8
22 1/4
0/12 - 4/12
0/12 - 4/12
4/12 - 8/12
4/12 - 8/12
4/12 - 8/12
8/12 - 12/12
8/12 - 12/12
8/12 - 12/12
0/12 - 4/12
0/12 - 4/12
0/12 - 4/12
4/12 - 8/12
4/12 - 8/12
4/12 - 8/12
8/12 - 12/12
8/12 - 12/12
8/12 - 12/12
Product Descriptions | EXCEL11
Wall Radiation Shields
(EWRS & EWRSI)
INCHES
Dimensions
Code
5EWRS/EWRSI
6EWRS/EWRSI
7EWRS/EWRSI
8EWRS/EWRSI
Stainless Trim for EWRS
(EST)
A
5
6
7
8
B
10
10
11
12
C
14 1/4
14 1/4
15 3/4
17
D
16 X 16
16 X 16
16 X 16
16 X 16
E
6-12
6-12
6-12
6-12
A decorative trim cover for the exterior wall plate of the Wall Radiation Shield that prevents water
infiltration while providing adequate heat ventilation.
INCHES
Dimensions
ø
6"
7"
8"
Insulated Angled Wall
Radiation Shields (EWRSI30 & EWRSI45)
A
16 1/4
16 1/4
16 1/4
B
8"
9"
10"
The insulated angled wall radiation shield is used when the chimney goes through a combustible
exterior wall, with a 30 or 45 degree angle. A radiation shield is installed on the exterior
side of the wall to complete the installation. This part is used for fireplace installations only.
Note: 45° are approved for use in Canada only.
INCHES
Required Opening Dimensions
Angle
ø
6"
7"
8"
Anchor Plate
30°
A
11 3/4
12 3/4
13 3/4
45°
B
38
40
42
A
11 3/4
12 3/4
13 3/4
B
27 7/16
28 7/8
30 1/4
Is used to connect an appliance (such as a masonry fireplace or heater) to an EXCEL chimney.
(EAP)
Anchor Plate Dampers
(EAPD, EAPD2)
Combines the anchor plate with a heavy gauge stainless steel damper to simplify masonry fireplace
construction, reduce installation cost and provides a superior seal.
INCHES
Dimensions
A
A
(EAP)
(EAPD)
(EAPD2)
Code
EAP
EAP - EAPD - EAPD2
EAP - EAPD - EAPD2
EAP - EAPD - EAPD2
Diameter
5
6
7
8
A
12" X 12
12" X 12
13" X 13
14" X 14
EXCEL
The wall radiation shield is used when the chimney passes horizontally through a combustible wall. The
EWRS telescopes to adjust for wall thickness from 6" – 12", so no painting is required. The inside finish
trim is separate from the EWRS, allowing for easy installation before or after the wall finish is applied.
The Insulated Wall Radiation Shield (EWRSI) is designed for installations in energy efficient houses
which have tightly sealed vapour barriers. The EWRSI is fully insulated and has a flange to permit an
air tight seal to the vapour barrier. It can be installed into an existing home but since it must be installed
under the drywall it is most often used for new construction. Flue extention and trim ring included.
12 Product Descriptions | EXCEL
EXCEL
NEW
Hardware Kit
(HK)
Locking Band
(ELB)
Roof Brace
Flue Extension
EXCEL insulated components are
designed to be fastened together with
the stainless steel screws provided with
each part. In some cases, it may be
desirable to install a locking band for
aesthetic purposes. The locking band
is designed to overlap the two beads
immediately above and below the
chimney joint and fastens with a 1/4"
bolt. All three screws are required even
when the ELB is installed.
Offset Support
The roof brace is used to provide lateral
support for a chimney which extends
more than 5 feet above a roof. The roof
brace utilizes a universal band to fit 6,
7 and 8 inch chimneys. The arms on
the roof brace telescope from 5 ft. to
9 ft. long.
(EX)
(EOS)
The flue extension fastens to the bottom
of the first chimney length with three
screws. It makes it possible to connect
a stove pipe, or other type of connector,
to the chimney. It is sometimes used to
connect an EXCEL chimney directly to an
appliance. The flue extension is designed
to fit a variety of stove pipes. However,
due to variations from one manufacturer
to another, some modification may be
required in the field.
The offset support is primarily used
to re-support the chimney above an
offset. However it can also be used
to provide additional support when the
chimney height exceeds the capacity of
the primary support. The offset support
straps are 24 inches long.
24"
NEW
Roof Brace
Stiffener (ERBS)
Prevents roof brace poles bending under
the weight of snow. Recommended for
metal roofs.
5’
TO
9’
(ERB)
Includes common bolts, thumbscrews,
wingnuts and washers for EXCEL installations.
Adjustable Stud
Support (EAS)
Allows you to install a round or square
support (ERDS, ES & ESS) without using
wood framing. The maximum support
capacity is 30 feet of chimney. The
maximum joist spacing is 24" center
to center.
Snow-Wedge
Fits roofs 4/12 to 12/12.
(ESW)
2" MIN
WOOD
SCREWS
ROOF SLOPE
Wall Channel
(EWC)
The wall channel enables a wall
support or wall band to be fastened
solidly to the framing when the framing
centres do not line up with the chimney
opening. The wall channel is 24" long.
Universal Vinyl
Siding Trim (EVT)
This piece comes as two sections
of galvanized metal. There are tabs
cut into the strips that allow for easy
bending at key points. Assembling
these brackets will create a vinyl siding
trim for any size of wall thimble in the
wood, pellet or gas venting products.
Product Descriptions | EXCEL13
Rain Caps
All EXCEL chimneys must be installed with an EXCEL rain cap (any model)
to prevent water from entering the chimney.
ERC: The regular rain cap is made from .016" thick type 304 stainless steel and carries
a one year warranty.
EDRC: The deluxe cap is made from .025" thick type 304 stainless steel and carries a lifetime
100% full replacement warranty.
Regular Rain Cap (ERC)
Rain Cap Deluxe (EDRC)
16"
Spark Screen (ERCS)
Rain/Wind Shield (ERCW)
ERCS: An optional stainless steel spark screen is available for installations where sparks
can pose a safety problem.
ERCW: The optional wind and rain shield improves draft by up to 40% in windy conditions
and is very effective at preventing wind driven rain from entering the chimney. It bolts
to the existing holes in either the regular or deluxe cap.
ERCB: The rain cap base is designed to cover the end of the chimney in applications where
a rain cap is not practical but it does not keep rain from entering the chimney.
ERRC: The revolving rain cap helps to prevent the entry of wind driven rain and helps to prevent
wind induced downdrafts.
13 1/2"
5"
Rain Cap Base (ERCB)
Revolving Rain Cap (ERRC)
Flashings
Flashings include a storm collar
(EF, EFA, EFB, EFC, ESF, ESFA, ESFC, EMFA, EMFB,
EMFC, ELFA, ELFB, ELFC, EVF, EVFA, EVFB, EVFC,
EFP, EDCF)
EF, EFA, EFB, EFC, ESF, ESFA & ESFC: These flashings are made from either galvalume steel, which
is considerably more corrosion resistant than galvanized, or from stainless steel for applications where
maximum corrosion resistance is desired. They are made to cover the entire range of roof pitches.
EMFA, EMFB & EMFC: These flashings are specifically designed for metal roofs and greatly
simplify metal roof installations. They are made from galvalume steel only.
ELFA, ELFB & ELFC: The flexible base flashing combines a stainless steel cone with a flexible
lead base which can be easily formed on site to match virtually any roof profile. It was designed
for masonry tile roofs but can be used wherever a flexible base is required except for metal roofs.
Ajustable Flashing
Metal Roof Flashing
“US Patent 7114301,
Can Patent 2460044”
EVF, EVFA, EVFC: Vented Flashings are required in certain applications where additioanl airflow
is required.
EFP: The adjustable peak flashing is designed to be used when the chimney passes through
the peak of the home. It will fit any peak between 2/12 and 12/12.
EDCF: The decorative cap flashing is made from galvalume steel only and is required with
the decorative cap.
INCHES
Flashing Specifications
Flat Flashing
Vented Flashing
Adjustable Peak
Flashing
Flexible Base Flashing
Code
5, 6, 7 & 8 EF
5, 6, 7 & 8 EFA
5, 6, 7 & 8 EFB
5, 6, 7 & 8 EFC
6, 7 & 8 EVF
6, 7 & 8 EVFA
6, 7 & 8 EVFB
6, 7 & 8 EVFC
5, 6, 7 & 8 EMFA
5, 6, 7 & 8 EMFB
5, 6, 7 & 8 EMFC
6, 7 & 8 ELFA
6, 7 & 8 ELFB
6, 7 & 8 ELFC
6, 7 & 8 EFP
6, 7 & 8 EDCF
Ventilation
not ventilated
not ventilated
not ventilated
not ventilated
ventilated
ventilated
ventilated
ventilated
not ventilated
not ventilated
not ventilated
not ventilated
not ventilated
not ventilated
not ventilated
ventilated
Fits Pitch Range
From Flat to 2/12
1/12 - 7/12
8/12 - 12/12
12/12 - 21/12
Flat 2/12
1/12 - 7/12
8/12 - 12/12
12/12 - 21/12
1/12 - 7/12
8/12 - 12/12
12/12 - 21/12
1/12 - 7/12
8/12 - 12/12
12/12 - 21/12
Peak 2/12 - 12/12
Flat
EXCEL
(ERC, EDRC, ERCS, ERCW, ERCW, ERRC)
Both models of storm collar fit
6, 7 and 8 inch EXCEL chimneys.
To form an attic insulation shield
assembly in an insulated space,
use a storm collar in combination
with a support box or radiation
shield. The ESQSC is required to
form an attic insulation shield on
a Square Support (ESS), all other
supports and radiation shields
can use either collar. If installing
5" EXCEL, use the storm collar for
EXCELDirect (TM-SC).
(ESC, ESQSC)
3"
ESC
51
/4
"
EXCEL
Storm Collar
ESQSC
Radiation Shield
REDESIGNED
14 Product Descriptions | EXCEL
Roof Radiation
Shield
(ERRS)
The roof radiation shield is
required with some roof support
and outside chase installations.
Position of the mounting brackets is adjustable for roof pitch.
The radiation shield protects combustible framing in the floor or ceiling adjacent to the chimney
and also acts as a firestop spacer. When the chimney passes through the radiation shield into an
insulated space a universal storm collar must also be installed to prevent the entry of insulation.
(ERS)
INCHES
Dimensions
Code
5ERS
6ERS
7ERS
8ERS
Radiation Shield
for Cathedral Ceiling
(ERSC)
A
10 1/2
10 1/2
11 1/2
12 1/2
B
16 X 16
16 X 16
16 X 16
16 X 16
C
12 - 22
12 - 22
12 - 22
12 - 22
For installations where EXCEL chimney extends through a pitched ceiling. The firestop trim is
adjustable to accommodate any pitch and has spacers to ensure that proper clearances are met.
In Canada, this part can be used in combination with factory built fireplaces only. For woodstove
installations in Canada, the Attic Radiation Shield for Cathedral Ceilings (ERSCA) is required in
combination with a Radiation Shield Tube.
INCHES
Dimensions
C
A
B
Code
6ERSC
7ERSC
8ERSC
A
8 1/4
9 1/4
10 1/4
B
10 1/4
11 1/4
12 1/4
C
24-38
24-38
24-38
Product Descriptions | EXCEL15
Canadian Components:
EXCEL
The following components are for Canadian installations only
and are not available in the USA.
Attic Radiation Shields
The radiation shield protects combustible framing in the floor or ceiling adjacent to the chimney
and also acts as a firestop spacer. When the chimney passes through the radiation shield into an
insulated space a universal storm collar must be installed on top of the ERSA to prevent the entry of
insulation. The ERSA has a flange on the bottom to fasten the radiation shield tube.
(ERSA)
INCHES
Dimensions
Code
5ERSA
6ERSA
7ERSA
8ERSA
Attic Radiation Shield for
Cathedral Ceiling
A
Ø 10 1/2
Ø 10 1/2
Ø 11 1/2
Ø 12 1/2
B
16 X 16
16 X 16
16 X 16
16 X 16
C
10 - 20
10 - 20
10 - 20
10 - 20
Canada Only, not available in USA
Similar to the Attic Radiation Shield (ERSA), only this component is designed for freestanding
woodstove installations where insulated chimney passes through a cathedral ceiling. The ERSCA
has a flange at its base to connect a Radiation Shield Tube.
(ERSCA)
INCHES
Dimensions
Code
6ERSCA
7ERSCA
8ERSCA
Radiation Shield Tubes
(ERST, ERSF & ERSF10)
ERST
ERSF10*
ERSF
A
10
11
12
B
24 – 38
24 – 38
24 – 38
Canada Only, not available in USA
The radiation shield tube is only used where the chimney is enclosed in the interior of the building
(e.g. between the basement ceiling and the attic). It is not required in the attic or on exterior chase
installations. It is not required when EXCEL is installed on a fireplace, gas or oil appliance. The ERST
or ERSF10 are for straight installations, the ERSF is used when an offset is required in the chimney.
*ERSF10 does not include a Square Support Adapter (SQSA); please order one separately for square
support installations.
INCHES
ERST Dimensions
Chimney
6" Ø
7" Ø
8" Ø
Diameter
9 3/4 - 10 3/4
10 3/4 - 11 3/4
11 3/4 - 12 3/4
Min. Length
32 1/4
32 1/4
32 1/4
Max. Length
98 1/4
98 1/4
98 1/4
Canada Only, not available in USA
INCHES
ERSF10 Dimensions
Chimney
6" Ø
7" Ø
8" Ø
Inside diameter
9 3/4
10 3/4
11 3/4
Min. Length
36
36
36
Max. Length
120
120
120
Canada Only, not available in USA
INCHES
ERSF Dimensions
Chimney
6" Ø
7" Ø
8" Ø
Inside diameter
9 3/4
10 3/4
11 3/4
Min. Length
45
45
45
Max. Length
137 1/2
137 1/2
137 1/2
Canada Only, not available in USA
16 Offset Tables | EXCEL
EXCEL
EXCEL Offset Tables
Use this table if you are not installing an
adjustable length between the elbows.
LENGTH
BETWEEN
OFFSETS
15° Elbows
RISE
NO LENGTH
9 1/4
6" Length
13 1/4
12" Length
19
18" Length
25
24" Length
30 3/4
48" Length
53 3/4
24" + 12"
40 1/2
48" + 12"
63 3/4
48" + 18"
69 1/2
48" + 24"
75 1/4
48"+24"+12"
85 1/4
48" + 48"
98 1/2
NO LENGTH
9 1/2
6" Length
13 1/2
12" Length
19 1/4
18" Length
25 1/4
24" Length
31
48" Length
54
24" + 12"
40 3/4
48" + 12"
64
48" + 18"
69 3/4
48" + 24"
75 1/2
48"+24"+12"
85 1/2
48" +48"
98 3/4
NO LENGTH
9 3/4
6" Length
13 3/4
12" Length
19 1/2
18" Length
25 1/2
24" Length
31 1/4
48" Length
54 1/2
24" + 12"
41
48" + 12"
64 1/4
48" + 18"
70
48" + 24"
75 3/4
48"+24"+12"
85 3/4
48" + 48"
99
NO LENGTH
10
6" Length
14
12" Length
19 3/4
18" Length
25 3/4
24" Length
31 1/2
48" Length
54 3/4
24" + 12"
41 1/4
48" + 12"
64 1/2
48" + 18"
70 1/4
48" + 24"
76 1/4
48"+24"+12"
86
48" + 48"
99 1/4
OFFSET
30° Elbows
RISE
5 INCH Ø
1 1/4 10 1/2
2 1/4 14 1/4
3 3/4 19 1/4
5 1/2 24 1/2
7
29 3/4
13 1/4 50 1/2
9 1/2 38 3/4
15 3/4 59 1/2
17 1/2 64 1/2
19
69 3/4
21 1/2 78 3/4
25 1/4 90 1/2
6 INCH Ø
1 1/4 11
2 1/4 14 3/4
4
19 3/4
5 1/2 25
7
30 1/4
13 1/4 51
9 3/4 39 1/4
15 3/4 60
17 1/2 65
19
70 1/4
21 3/4 79 1/4
25 1/4 91
7 INCH Ø
1 1/4 11 1/2
2 1/2 15 1/4
4
20 1/4
5 1/2 25 1/2
7
30 3/4
13 1/4 51 1/2
9 3/4 39 3/4
16
60 1/2
17 1/2 65 1/2
19
70 3/4
21 3/4 79 3/4
25 1/4 91 1/2
8 INCH Ø
1 1/4 12
2 1/2 15 3/4
4
20 3/4
5 1/2 26
7
31 1/4
13 1/4 52
9 3/4 40 1/4
16
61
17 1/2 66
19
71 1/4
21 3/4 80 1/4
25 1/4 92
OFFSET
45° Elbows
RISE
OFFSET
Use this table when an 18 inch
adjustable length is required.
LENGTH
BETWEEN
OFFSETS
15° Elbows
RISE
30° Elbows
OFFSET
RISE
45° Elbows
OFFSET
RISE
OFFSET
34 1/4 56 1/4 49 1/4
48"+24"+12"
37 1/4 60 1/2 53 1/2
48" +48"
5 INCH Ø
23 - 28 3/4
5 - 6 1/2
22 3/4 - 28
28 3/4 - 34 1/2 6 1/2 - 8
28 - 33 1/4
34 1/2 - 40 1/4 8 - 9 1/2
33 1/4 - 38 1/2
40 1/4 - 46 1/4 9 1/2 - 11
38 1/2 - 43 1/2
63 1/2 - 69 1/4 15 3/4 - 17 1/ 4 59 1/4 - 64 1/2
50 1/4 - 56
12 1/4 - 13 3/4 47 1/4 - 52 1/2
73 1/2 - 79 1/4 18 1/2 - 20
68 - 73 1/4
79 1/4 - 85
20 - 21 1/2
73 1/4 - 78 1/2
85 - 90 3/4
21 1/2 - 23
78 1/2 - 83 3/4
95 - 100 3/4
24 1/4 - 25 3/4 87 1/4 - 92 1/2
108 1/4 - 114
27 3/4 - 29 1/4 99 1/4 - 104 1/2
6 INCH Ø
23 1/4 - 29
5 - 6 1/2
23 1/4 - 28 1/2
29 - 34 3/4
6 1/2 - 8
28 1/2 - 33 3/4
34 3/4 - 40 1/2 8 - 9 1/2
33 3/4 - 39
40 1/2 - 46 1/2 9 1/2 - 11 1/4
39 - 44
63 3/4 - 69 1/2 15 3/4 - 17 1/4 59 3/4 - 65
50 1/2 - 56 1/4 12 1/4 - 13 3/4 47 3/4 - 53
73 3/4 - 79 1/2 18 1/2 - 20
68 1/2 - 73 3/4
79 1/2 - 85 1/4 20 - 21 1/2
73 3/4 - 79
85 1/4 - 91
21 1/2 - 23
79 - 84 1/4
95 1/4 - 101
24 1/4 - 25 3/4 87 3/4 - 93
108 1/2 - 114 1/4 27 3/4 - 29 1/4 99 3/4 - 105
6" Length
23 1/2 - 29 1/4
5 - 6 1/2
23 3/4 - 29
10 1/4 - 13 1/4
22 3/4 - 27
15 1/4 - 19 1/2
12" Length
29 1/4 - 35
6 1/2 - 8
29 - 34 1/4
13 1/4 - 16 1/4
27 - 31 1/4
19 1/2 - 23 3/4
2 3/4
11 1/4 4 3/4
6" Length
5
14 1/4 7 3/4
12" Length
8
18 1/2 12
18" Length
11
22 3/4 16 1/4
24" Length
14
27
20 1/2
48" Length
26
44
37 1/2
24" + 12"
19
34 1/4 27 3/4
48" + 12"
31
51 1/4 44 3/4
48" + 18"
34
55 1/2 49
48" + 24"
37
59 3/4 53 1/4
48"+24"+12"
42 1/4 67
60 1/2
48" + 48"
49
76 3/4 70
3
12
5
6" Length
12" Length
5
15
8
18" Length
8
19 1/4 12 1/4
24" Length
11
23 1/2 16 1/2
48" Length
14
27 3/4 20 3/4
24" + 12"
26
44 3/4 37 3/4
48" + 12"
19 1/4 35
28
48" + 18"
31 1/4 52
45
48" + 24"
21 1/2 - 25 3/4
14 3/4 - 19
13 - 16
25 3/4 - 30
19 - 23 1/4
16 - 19
30 - 34 1/4
23 1/4 - 27 1/2
19 - 22
34 1/4 - 38 1/2
27 1/2 - 31 3/4
31 - 34
51 1/4 - 55 1/4
44 1/2 - 48 3/4
24 - 27
41 1/2 - 45 3/4
34 1/4 - 39
36 - 39
58 1/4 - 62 1/2
51 3/4 - 56
39 - 42
62 1/2 - 66 3/4
56 - 60 1/4
42 - 45
66 3/4 - 71
60 1/4 - 64 1/2
47 1/4 - 50 1/4
74 - 78 1/4
67 1/2 - 71 3/4
54 - 57
83 3/4 - 88
77 1/4 - 81 1/2
10 - 13
13 - 16
22 1/4 - 26 1/2 15 - 19 1/4
26 1/2 - 30 1/2 19 1/4 - 23 1/2
16 - 19
30 1/2 - 34 3/4
23 1/2 - 27 3/4
19 - 22
34 3/4 - 39
27 3/4 - 32
31 - 34
51 3/4 - 56
44 3/4 - 49
24 1/4 - 27 1/4
42 - 46 1/4
35 - 39 1/4
36 1/4 - 39 1/4
59 - 63 1/4
52 - 56 1/4
39 1/4 - 42 1/4
63 1/4 - 67 1/2
56 1/4 - 60 1/2
42 1/4 - 45 1/4
67 1/2 - 71 3/4
60 1/2 - 64 3/4
47 1/4 - 50 1/4
74 3/4 - 79
67 3/4 - 72
54 1/4 - 57 1/4
84 1/2 - 88 3/4
77 1/2 - 81 3/4
7 INCH Ø
42 1/4 67 3/4 60 3/4
49 1/4 77 1/2 70 1/2
10 - 13
3
12 3/4 5 1/4
18" Length
35 - 40 3/4
8 - 9 1/2
34 1/4 - 39 1/2
16 1/4 - 19 1/4
31 1/4 - 35 1/2
23 3/4 - 28
5 1/4
15 3/4 8 1/4
24" Length
40 3/4 - 46 3/4
9 1/2 - 11 1/4
39 1/2 - 44 1/2
19 1/4 - 22 1/4
35 1/2 - 39 3/4
28 - 32 1/4
8 1/4
20
48" Length
64 - 69 3/4
15 3/4 - 17 1/2
60 1/4 - 65 1/2
31 1/4 - 34 1/4
52 1/2 - 56 3/4
45 - 49 1/4
11 1/4 24 1/4 16 3/4
24" + 12"
50 3/4 - 56 1/2
12 1/4 - 13 3/4
48 1/4 - 53 1/2
24 1/4 - 27 1/4
42 3/4 - 47
35 1/4 - 39 1/2
14 1/4 28 1/2 21
48" + 12"
74 - 79 3/4
18 1/2 - 20
69 - 74 1/4
36 1/4 - 39 1/4
59 3/4 - 64
52 1/4 - 56 1/2
26 1/4 45 1/2 38
48" + 18"
79 3/4 - 85 1/2
20 - 21 1/2
74 1/4 - 79 1/2
39 1/4 - 42 1/4
64 - 68 1/4
56 1/2 - 60 3/4
19 1/4 35 3/4 28 1/4
48" + 24"
85 1/2 - 91 1/4
21 1/2 - 23 1/4
79 1/2 - 84 3/4
42 1/4 - 45 1/4
68 1/4 - 72 1/2
60 3/4 - 65
31 1/4 52 3/4 45 1/4
48"+24"+12"
95 1/2 - 101 1/4 24 1/4 - 25 3/4
88 1/4 - 93 1/2
47 1/2 - 50 1/2
75 1/2 - 79 3/4
68 - 72 1/4
34 1/4 57
48" + 48"
108 3/4 - 114 1/2 27 3/4 - 29 1/4
100 1/4 - 105 1/2 54 1/4 - 57 1/4
85 1/4 - 89 1/2
77 3/4 - 82
42 1/2 68 1/2 61
6" Length
23 3/4 - 29 1/2
5 - 6 1/2
24 1/4 - 29 1/2
10 1/4 - 13 1/4
23 1/2 - 27 3/4
15 3/4 - 20
49 1/4 78 1/4 70 3/4
12" Length
29 1/2- 35 1/4
6 1/2 - 8
29 1/2 - 34 3/4
13 1/4 - 16 1/4
27 3/4 - 32
20 - 24 1/4
18" Length
24" Length
48" Length
24" + 12"
48" + 12"
48" + 18"
48" + 24"
48"+24"+12"
48" + 48"
35 1/4 - 41
41 - 47
64 1/4 - 70
51 - 56 3/4
74 1/4 - 80
80 - 85 3/4
85 3/4 - 91 1/2
95 3/4 - 101 1/2
109 - 114 3/4
8 - 9 3/4
9 3/4 - 11 1/4
15 3/4 - 17 1/2
12 1/4 - 13 3/4
18 1/2 - 20
20 - 21 3/4
21 3/4 - 23 1/4
24 1/4 - 25 3/4
27 3/4 - 29 1/2
34 3/4 - 40
40 - 45
60 3/4 - 66
48 3/4 - 54
69 1/2 - 74 3/4
74 3/4 - 80
80 - 85 1/4
88 3/4 - 94
100 3/4 - 106
16 1/4 - 19 1/4
19 1/4 - 22 1/4
31 1/4 - 34 1/4
24 1/2 - 27 1/2
36 1/2 - 39 1/2
39 1/2 - 42 1/2
42 1/2 - 45 1/2
47 1/2 - 50 1/2
54 1/2 - 57 1/2
32 - 36 1/4
36 1/4 - 40 1/2
53 1/4 - 57 1/2
43 1/2 - 47 3/4
60 1/2 - 64 3/4
64 3/4 - 69
69 - 73 1/4
76 1/4 - 80 1/2
86 - 90 1/4
24 1/4 - 28 1/2
28 1/2 - 32 3/4
45 1/4 - 49 1/2
35 3/4 - 40
52 1/2 - 56 3/4
56 3/4 - 61
61 - 65 1/4
68 1/4 - 72 1/2
78 - 82 1/4
12 1/2
49 1/2
8 INCH Ø
37 1/4 61 1/4 53 3/4
3 1/4
13 1/2 5 1/2
5 1/4
16 1/2 8 1/2
8 1/4
20 3/4 12 3/4
11 1/4 25
17
14 1/4 29 1/4 21 1/4
26 1/4 46 1/4 38 1/4
19 1/2 36 1/2 28 1/2
31 1/2 53 1/2 45 1/2
34 1/2 57 3/4 49 3/4
37 1/2 62
54
42 1/2 69 1/4 61 1/4
49 1/2 79
71
All measurements are in inches
All measurements are in inches
ULTRABlack
DOUBLE WALL STOVE PIPE
ULTRABlack
18 Technical Information | ULTRABlack
ULTRABlack Technical Information
Certification
Allowable Flue Gas Temperatures
ULTRABlack has been tested and listed by Intertek Testing
Services. Listing #5965
Max Continuous
650°C (1200°F)
Brief Forced Firing 925°C (1700°F)
Tested To
1150°C (2100°F)
Applications
ULTRABlack is designed to be used as a connector
between a freestanding oil, wood or coal burning stove
and a masonry or metal chimney. There are four primary
advantages to ULTRABlack over single wall connector
pipes:
▪▪ It offers reduced clearance to combustible materials.
▪▪ It is designed to last the lifetime of the stove and/or
chimney system.
▪▪ It offers reduced creosote formation.
▪▪ It is certified for use with mobile home stoves.
Clearance to Combustible Materials
ULTRABlack is certified for 6" clearance with the following
exception. When ULTRABlack is used as the connector on
a mobile home certified stove the clearance is determined
by the installation instructions for the specific stove model
being installed.
Construction
Flue: .016" stainless steel.
Casing: .019" satin coat steel. Satin coat is specifically
designed to be painted.
Seam: Interior and exterior seams are seam welded.
Wall thickness: Approximately 3/8"
Paint: Forrest “Stove Bright” flat black
ULTRABlack Engineering and Design Considerations
Maximum allowable overall height:
EXCEL ULTRABlack
There is no maximum requirement however, as a general
guideline we recommend that the length of ULTRABlack
not exceed 20 feet.
Fully Shielded Stove pipe with smooth, clean lines.
ULTRABlack assembles like a regular single wall stove
pipe - no complicated, unsightly twist lock connectors or
spot welds. There is no cutting required and all the screw
holes are predrilled. Just put one piece on top of the other
and screw together using the black oxide screws provided.
Easily fits most stoves, including cast iron stoves and
stoves with oval collars. ULTRABlack is approved for
mobile home installation on most major stove brands,
when installed with EXCEL insulated chimney. For mobile
home installations follow the stove manufacturer’s
installation instructions.
▪▪ Requires just 6" clearance to combustibles in all
diameters - even when installed in a corner, or parallel
with a ceiling*.
▪▪ Has a smooth, clean appearance to compliment any
stove installation.
▪▪ Maximizes flue gas temperature, insuring good draft.
▪▪ Minimizes creosote buildup.
* Some stoves may require greater clearances.
4005717
Product Descriptions | ULTRABlack19
Lengths
(UB5F, UB1F, UB18F, UB2F & UB3F)
Adjustable Lengths
Slip Lengths
Adjustable Length
(UBAF)
(UB6SF, UB1SF & UB18SF)
Lengths are available in 5", 12", 18", 24" and 36".
Adjustable Lengths combine a 36" length and a 36" slip length in one box. The UBAF fits all brands
of insulated chimney and most brands of wood burning stoves without a stove or chimney adapter.
A UBTC trim collar is included with the UBAF.
Slip Lengths slide over a regular straight length allowing you to adjust the overall length of a straight
run without cutting. The minimum adjustment can be reached only if the length used below the slip
length is long enough to accept it.
Lengths
INCHES
Length Dimensions (6-7-8")
Code
6-7-8 UB5F
6-7-8 UB1F
6-7-8 UB18F
6-7-8 UB2F
6-7-8 UB3F
A
5
12
18
24
36
B
4
11
17
23
35
INCHES
Slip Length Dimensions
Slip length
Code
UB6SF
UB1SF
UB18SF
A MIN.
2
2
2
A MAX.
6
12
18
B MIN.
1
1
1
B MAX.
5
11
17
INCHES
Adjustable Length Dimensions
Code
6UBAF
7UBAF
8UBAF
Tees
(UBT)
A MIN.
40
40
40
A MAX.
68
68
68
B MIN.
39
39
39
B MAX.
67
67
67
Combines a 90° transition with a clean out. Includes a tee cap.
INCHES
Dimensions
Code
6UBT
7UBT
8UBT
Elbows
A
12
12
12
B
11
11
11
C
6
6
6
D
5 7/8
6 3/8
6 7/8
Are available in 30°, 45° and 90°.
INCHES
(UB30, UB45 & UB90)
Dimensions (30°, 45°, 90°)
Code
6UB30
7UB30
8UB30
6UB45
7UB45
8UB45
6UB90
7UB90
8UB90
A
2 5/16
2 7/16
2 9/16
2 3/4
2 15/16
3 1/8
5 9/16
6 1/16
6 9/16
B
2 9/16
2 11/16
2 13/16
3
3 3/16
3 3/8
4 1/2
5
5 1/2
ULTRABlack
ULTRABlack Product Descriptions
ULTRABlack
20 Product Descriptions | ULTRABlack
Reducers
(UBR)
Designed to reduce the diameter of a system to accommodate a range of flue sizes, appliances and
installations. Note: Decreasing chimney diameter even 1" can have a serious negative impact of
chimney performance. Be careful to use these components only when appropriate.
INCHES
Dimensions
Code
UBR76
UBR86
UBR87
Increasers
(UBI)
A
7
8
8
B
6
6
7
C
7
7
7
Designed to increase the diameter of a system to accommodate a range of flue sizes, appliances and
installations. Note: Increasing chimney diameter can reduce draft and increase creosote formation.
Be careful to use these components only when appropriate.
INCHES
Dimensions
Code
UBI56
UBI67
UBI68
UBI78
Oval to Round Adapter
(UBORF)
A
5
6
6
7
B
6
7
8
8
C
7
7
7
7
Adapters are designed to connect ULTRABlack to stoves with oval flue collars - such as a Vermont
Castings Defiant Encore. Available in 8" only.
INCHES
Dimensions (8" only)
Code
8UBORF
Stove Adapters
(UBSE)
A
18
B
17
C
8
D
5 3/4
E
10 3/4
Connect ULTRABlack to stoves with flue collars that do not project above the top of the stove. It can
also be used to connect to stoves with irregular shaped or sized flue collars.
INCHES
Dimensions
Code
6UBSE
A
2 1/2
B
1 1/2
7UBSE
2 1/2
1 1/2
8UBSE
2 1/2
1 1/2
Product Descriptions | ULTRABlack21
This part acts as a thimble sleeve to connect ULTRABlack to a masonry chimney that does not have a
thimble or has an oversize one. Note: ULTRABlack is not certified to pass through a combustible wall.
An EXCELiner Insulated Thimble (ITH) must be used where there is a combustible wall between the
stove and the masonry chimney.
(UBM)
INCHES
Dimensions
NEW
Masonry Thimble
Adapter (UBMA)
Code
A
B
C
D
6UBM
11 7/8
10 7/8
12
6 1/8
7UBM
8UBM
11 7/8
11 7/8
10 7/8
10 7/8
13
14
7 1/8
8 1/8
Connect ULTRABlack to a masonry chimney with an existing 8" thimble. Note: ULTRABlack is not
certified to pass through a combustible wall. An EXCELiner Insulated Thimble (ITH) must be used where
there is a combustible wall between the stove and the masonry chimney.
C
INCHES
Dimensions
D
Code
A
B
C
D
6UBMA
6 7/8
11 1/8
7 1/2
4 3/4
A
B
Damper Section
Butterfly type in line dampers. They are recommended by some stove manufacturers to help control draft.
INCHES
(UBD)
Dimensions
A
Code
A
B
UBD
5
4
B
Trim Collars
Covers the crimped (top) end of ULTRABlack where it connects to the insulated chimney. A UBTC is
included with every UBAF and UBT so they rarely need to be purchased separately.
(UBTC)
INCHES
Dimensions
Code
6UBTC
7UBTC
8UBTC
Conical Trim Ring
(UBTR)
22 x 2
25 3/8 x 2
28 1/2 x 2
Adjustable to fit the exterior of regular ULTRABlack lengths and slip lengths. There are also slots to
fit fixed and slip EXCELDirect lengths as well as single wall black pipe. Available in 6" or 8".
INCHES
Dimensions
A
A
3"
ULTRABlack
Masonry Adapter
ULTRABlack
22 Offset Tables | ULTRABlack
ULTRABlack Offset Tables
45° ELBOWS
45° ELBOWS
UB OFFSET TABLE - Use this table if
you are not installing a slip length
(UBSF) between the elbows.
LENGTH BETWEEN
ELBOWS
6 INCH Ø
NO LENGTH
5" Length
12" Length
18" Length
24" Length
36" Length
7 INCH Ø
NO LENGTH
5" Length
12" Length
18" Length
24" Length
36" Length
8 INCH Ø
NO LENGTH
5" Length
12" Length
18" Length
24" Length
36" Length
UB OFFSET TABLE - Use this table if you are installing
an adjustable length between the elbows.
LENGTH BETWEEN
45 ELBOWS
45° Elbows
RISE
OFFSET
8 1/4
11
16
20 1/4
24 1/2
33
3 1/2
6 1/4
11 1/4
15 1/2
19 3/4
28 1/4
9
11 3/4
16 3/4
21
25 1/4
33 3/4
3 3/4
6 1/2
11 1/2
15 3/4
20
28 1/2
9 3/4
12 1/2
17 1/2
21 3/4
26
34 1/2
4
7
11 3/4
16
20 1/4
28 3/4
All measurements are in inches
RISE
OFFSET
6 INCH Ø
NO LENGTH + UB6SF
5" LENGTH + UB6SF
5" LENGTH + UB12SF
12" LENGTH + UB12SF
18" LENGTH + UB12SF
24" LENGTH + UB18SF
UBAF
18" LENGTH + UBAF
36"+36"+12" + UB18SF
36"+36"+24" + UB18SF
36"+36"+36" + UB18SF
7 INCH Ø
NO LENGTH + UB6SF
5" LENGTH + UB6SF
5" LENGTH + UB12SF
12" LENGTH + UB12SF
18" LENGTH + UB12SF
24" LENGTH + 18UBSF
UBAF
18" LENGTH + UBAF
36"+36"+12" + UB18SF
36"+36"+12" + UB18SF
36"+36"+12" + UB18SF
8 INCH Ø
NO LENGTH + UB6SF
5" LENGTH + UB6SF
5" LENGTH + UB12SF
12" LENGTH + UB12SF
18" LENGTH + UB12SF
24" LENGTH + 18UBSF
UBAF
18" LENGTH + UBAF
36"+36"+12" + UB18SF
36"+36"+12" + UB18SF
36"+36"+12" + UB18SF
45° Elbows
RISE
OFFSET
9 1/4 - 11
12 - 14
16 - 18 1/4
17 - 23
21 1/4 - 27 1/4
25 1/2 - 35 3/4
36 1/2 - 56 1/4
47 3/4 - 67 3/4
66 1/2 - 76 3/4
75 - 85 1/4
83 1/2 - 93 3/4
4 1/2 - 6 1/4
7 1/4 - 9 1/4
11 1/4 - 13 1/2
12 1/4 - 18 1/4
16 1/2 - 22 1/2
20 3/4 - 31
31 3/4 - 51 1/2
43 - 63
61 3/4 - 72
70 1/4 - 80 1/2
78 3/4 - 89
10 - 11 3/4
12 3/4 - 14 3/4
16 3/4 - 19
17 3/4 - 23 3/4
22 - 28
26 1/4 - 36 1/2
37 1/4 - 57
48 1/2 - 68 1/2
67 1/4 - 77 1/2
75 3/4 - 86
84 1/4 - 94 1/2
4 3/4 - 6 1/2
7 1/2 - 9 1/2
7 1/2 - 13 3/4
12 1/2 - 18 1/2
16 3/4 - 22 3/4
21 - 31 1/4
32 - 51 3/4
43 1/4 - 63 1/4
62 - 72 1/4
70 1/2 - 80 3/4
79 - 89 1/4
10 1/2 - 12 1/2
13 1/2 - 15 1/4
17 1/2 - 19 1/2
18 1/4 - 24 1/2
22 1/2 - 28 3/4
26 3/4 - 37 1/4
38 - 57 3/4
49 1/4 - 69
67 3/4 - 78 1/4
76 1/4 - 86 3/4
84 3/4 - 95 1/4
5-7
7 3/4 - 9 3/4
7 3/4 - 14
12 3/4 - 19
17 - 23 1/4
21 1/4 - 31 3/4
32 1/4 - 52 1/4
43 3/4 - 63 1/2
62 1/4 - 72 3/4
70 3/4 - 81 1/4
79 1/4 - 89 1/2
All measurements are in inches
Offset Tables | ULTRABlack23
30° ELBOWS
UB OFFSET TABLE- Use this table if you are installing an adjustable
length between the elbows.
30° Elbows
30° Elbows
LENGTH BETWEEN
ELBOWS
RISE
OFFSET
6 INCH Ø
NO LENGTH
7 1/4
2
5" Length
10 1/2
4
5" LENGTH + UB12SF
16 3/4 - 19 1/4
7 1/2 - 9
12" Length
16 3/4
7 1/2
12" LENGTH + UB12SF
17 3/4 - 25 1/4
8 1/4 - 12 1/2
18" Length
21 3/4
10 1/2
18" LENGTH + UB12SF
23 - 30 1/2
11 1/4 - 15 1/2
24" Length
27
13 1/2
24" LENGTH + UB18SF
28 1/4 - 41
14 1/4 - 21 1/2
36" Length
37 1/2
19 1/2
UBAF
41 3/4 - 66
22 - 36
18" LENGTH + UBAF
55 1/2 - 79 3/4
30 - 44
36"+36"+12" + UB18SF
78 1/4 - 91 1/4
43 1/4 - 50 1/2
LENGTH
BETWEEN
OFFSETS
6 INCH Ø
RISE
7 INCH Ø
OFFSET
RISE
OFFSET
NO LENGTH + UB6SF
8 1/4 - 10 1/2
2 3/4 - 4
5" LENGTH + UB6SF
11 3/4 - 14
4 3/4 - 6
NO LENGTH
7 3/4
2
5" Length
11
4
36"+36"+24" + UB18SF
88 3/4 - 101 1/2
49 1/4 - 56 1/2
12" Length
17 1/4
7 1/2
36"+36"+36" + UB18SF
99 1/4 - 112
55 1/4 - 62 1/2
18" Length
22 1/4
10 1/2
7" INCH Ø
24" Length
27 1/2
13 1/2
NO LENGTH + UB6SF
8 3/4 - 11
2 3/4 - 4
36" Length
38
19 1/2
5" LENGTH + UB6SF
12 1/4 - 14 1/2
4 3/4 - 6
5" LENGTH + UB12SF
17 1/4 - 19 3/4
7 1/2 - 9
NO LENGTH
8 1/4
2 1/4
12" LENGTH + UB12SF
18 1/4 - 25 3/4
8 1/4 - 12 1/2
5" Length
11 3/4
4 1/4
18" LENGTH + UB12SF
23 1/2 - 31
11 1/4 - 15 1/2
12" Length
17 3/4
7 3/4
24" LENGTH + 18UBSF
28 3/4 - 41 1/2
14 1/4 - 21 1/2
18" Length
23
10 3/4
UBAF
42 1/4 - 66 1/2
22 – 36
24" Length
28 1/4
13 3/4
18" LENGTH + UBAF
56 – 80 1/4
30 – 44
36" Length
38 1/2
19 3/4
36"+36"+12" + UB18SF
78 3/4 - 91 3/4
43 1/4 - 50 1/2
36"+36"+12" + UB18SF
89 1/4 - 102
49 1/4 - 56 1/2
36"+36"+12" + UB18SF
99 3/4 - 112 1/2
55 1/4 - 62 1/2
8 INCH Ø
All measurements are in inches
8" INCH Ø
NO LENGTH + UB6SF
9 1/4 - 11 3/4
3 - 4 1/4
5" LENGTH + UB6SF
12 3/4 - 15 1/4
5 - 6 1/4
5" LENGTH + UB12SF
17 3/4 - 20 1/4
7 3/4 - 9 1/4
12" LENGTH + UB12SF
18 3/4 - 26 1/2
8 1/2 - 12 3/4
18" LENGTH + UB12SF
24 - 31 3/4
11 1/2 - 15 3/4
24" LENGTH + 18UBSF
29 1/4 - 42
14 1/2 - 21 3/4
22 1/4 - 36 1/4
UBAF
43 – 67 1/4
18" LENGTH + UBAF
56 3/4 - 81
30 1/4 - 44 1/4
36"+36"+12" + UB18SF
79 1/2 - 92 1/4
43 1/2 - 50 3/4
36"+36"+12" + UB18SF
89 3/4 - 102 3/4
49 1/2 - 56 3/4
36"+36"+12" + UB18SF
100 1/4 - 113
55 1/2 - 62 3/4
All measurements are in inches
ULTRABlack
30° ELBOWS
UB OFFSET TABLE- Use this table when a
slip length (UBSF) is not installed between
the elbows.
REVOLUTIONARY
NEW STOVE PIPE
THE ONLY STOVE PIPE LISTED FOR4" CLEARANCE WITH SHIELDING
4" CLEARANCE VERTICAL
4" CLEARANCE HORIZONTAL
EXCELPrime
SINGLE WALL STOVE PIPE
EXCELPrime
26 Technical Information | EXCELPrime
EXCELPrime Technical Information
Certification
Clearance to Combustible Materials
EXCELPrime has been tested and listed by Intertek Testing
Services
EXCELPrime is certified for 18" clearance to combustible
materials.
Applications
With the addition of a listed EXCELPrime Heat Shield, the
clearance can be reduced to:
EXCELPrime is designed to be used as a connector
between a freestanding oil, wood or coal burning stove
and a masonry or metal chimney.
Allowable Flue Gas Temperatures
Max Continuous
Brief Forced Firing
Tested To
650°C (1200°F)
925°C (1700°F)
1150°C (2100°F)
6" dia.
7" & 8" dia.
- 4" clearance from the shield
- 6" clearance from the shield
Construction
Single Wall: 22ga steel
Seam: Laser seam welded
Paint: Forrest “Stove Bright” flat black
EXCELPrime Engineering and Design Considerations
Maximum allowable overall height:
EXCELPrime
EXCELPrime must not exceed 10 feet in length and a
maximum of two 90 degree elbows is permitted.
Single wall stove pipe with smooth, clean lines
To assemble EXCELPrime, ensure that the shrunken end
is facing down. Place one length on top of another and
screw them together using the screws provided. There is
no cutting required and all the screw holes are predrilled.
EXCELPrime easily fits most stoves including cast iron
stoves and stoves with oval collars.
▪▪ Laser welded to be perfectly round and does not
require assembly like snap lock pipes.
▪▪ Heavy wall, 22ga steel
▪▪ Has a 5 year, no questions asked replacement warranty
▪▪ Without shielding, EXCELPrime requires 18" clearance
to combustibles in all diameters.
▪▪ With an EXCELPrime UL Listed Heat Shield, clearance
to combustibles can be reduced to 4" from the exterior
of the shield for 6" EXCELPrime or 6" clearance for 7 &
8" EXCELPrime.
4005717
Product Descriptions | EXCELPrime27
Lengths are available in 12", 18", 24", 36" and 48" lengths; 6", 7" and 8" diameter.
(SW1, SW18, SW2, SW3, SW4)
Slip Length
(SW1S)
Slip Lengths will slide into a regular straight length allowing you to adjust the overall length of a
straight run without cutting. The minimum adjustment can be reached only if the length used below
the slip length is long enough to accept it.
INCHES
Length Dimensions
Code
SW1
SW18
SW2
SW3
SW4
A
12
18
24
36
48
B
10 5/8
16 5/8
22 5/8
34 5/8
46 5/8
INCHES
Slip Length Dimensions
Code
SW1S
Adjustable Length
(SWA)
Min. Installed Length
1 3/8
Max. Installed Length
12
Adjustable Lengths combine a 36" length and a 36" slip length in one box. The SWA provides enough
range that it is often the only component required for vertical installations.
INCHES
Adjustable Length Dimensions
Code
SWA
Tee
A MIN.
40
A MAX.
68
B MAX.
66 5/8
Combines a 90° transition with a clean out. Tee Cap (SWTP) not included.
INCHES
(SWT)
Dimensions
Code
6SWT
7SWT
8SWT
Tee Cap
B MIN.
38 5/8
A
10 5/8
10 5/8
10 5/8
B
4 1/4
4 3/4
5 1/4
C
4 3/4
4 3/4
4 3/4
Caps off the open portion of a Tee.
INCHES
(SWTP)
Dimensions
Code
6SWTP
7SWTP
8SWTP
A
6
7
8
B
1
1
1
EXCELPrime
Length
EXCELPrime
28 Product Descriptions | EXCELPrime
Elbow
Are available in 45° and 90°
INCHES
(SW45, SW90)
Dimensions
Code
6SW45
7SW45
8SW45
6SW90
7SW90
8SW90
Slip Elbow 90°
A
2 5/8
2 7/8
3 1/8
4 3/4
5 1/4
5 3/4
Combines a 90° elbow and a slip length in one piece.
INCHES
(SW90S)
Dimensions
Code
6SW90S
7SW90S
8SW90S
Clean Out Elbow 90°
A max.
19 3/4
19 3/8
19 1/8
A min.
4
4 1/2
5
B
5 5/8
6 1/8
6 5/8
Incorporates an easily removable inspection port that is large enough for a chimney brush.
INCHES
(SW90C)
Dimensions
Code
6SW90C
7SW90C
8SW90C
Adjustable Elbow 90°
B
2 1/4
2 1/4
2 1/2
5 3/8
5 7/8
6 3/8
A
4 5/8
5 1/8
5 5/8
B
6
6 1/2
7
The angle of this elbow is variable between 90° and straight. Patent Pending
INCHES
(SWA90)
Dimensions
Code
6SWA90
7SWA90
8SWA90
A
5 3/8
5 7/8
6 3/8
B
6 3/8
6 7/8
7 3/8
Product Descriptions | EXCELPrime29
Designed to increase the diameter of a system to accommodate a range of flue sizes, appliances
and installations. Note: Increasing chimney diameter can reduce draft and increase creosote
formation. Be careful to use these components only when appropriate.
(SWSI)
INCHES
Dimensions
Code
SWSI67
SWSI68
A
6
6
B
7 1/8
8 1/8
C
2 5/8
2 5/8
Small end male
Reducer
(SWSR)
Small end female
Designed to reduce the diameter of a system to accommodate a range of flue sizes, appliances and
installations. Note: Decreasing chimney diameter even 1" can have a serious negative impact on
chimney performance. Be careful to use these components only when appropriate.
INCHES
Dimensions
Code
SWSR76
SWSR87
SWSR86
Oval to Round Adapter
A
7
8
8
B
6 1/8
7 1/8
6 1/8
Connects EXCELPrime to stoves with oval flue collars. Available in 8" only.
INCHES
(8SWOR)
Dimensions
Code
8SWOR
NEW
12" Slip Flue Extension
(SWEX)
C
2 1/2
2 1/2
2 1/2
A
9
B
7 7/8
C
8
D
5 3/4
E
10 3/8
Can be used to replace the EXCEL Flue Extension (EX) in EXCELPrime installations. This 12" long
version will slip into a standard length, eliminating the need for a slip length.
INCHES
Dimensions
Code
6SWEX
A
5 7/8
B
8
C MIN.
1/2
C MAX.
10 - 3/4
EXCELPrime
Increaser
EXCELPrime
30 Product Descriptions | EXCELPrime
Masonry Adapter
(SWM)
Connects 6" EXCELPrime to a 7" or 8" masonry chimney thimble. Note: EXCELPrime is not certified
to pass through a combustible wall. An EXCELiner Insulated Thimble (ITH, page 35) must be used
where there is a combustible wall between the stove and the masonry chimney.
INCHES
Dimensions
Code
6SWM
Masonry Plug
(SWMP)
A
6 1/4
B
10 1/2
C
6 5/8
D
4 3/4
Plugs the opening into an existing masonry chimney that had been previously used to vent another
appliance. The Masonry Plug is capable of plugging a round opening up to 8" diameter and is lined
with insulation to prevent cold drafts.
INCHES
Dimensions
Code
SWMP
Heat Shield
(SW1HS, SW2HS, SW3HS, SW45HS, SW90HS)
A
10 1/2
B
5 7/8
C
4 3/4
Reduces clearance required from combustible walls and ceilings. EXCELPrime heat shields are UL
listed in combination with EXCELPrime only and will not reduce the clearance of other brands of
stove pipe to the clearances listed below. For other brands of single wall stove pipe, clearances
will be reduced to those of an unlisted heat shield installation. Available in 12", 24", 36", 45°
and 90° designs.
INCHES
Clearance
Diameter
6"
7"
8"
Clearance to Combustibles from Shielding
4"
6"
6"
CONNECTOR
6" Ø ; 4" MIN.
7" AND 8" Ø ; 6" MIN.
SHIELD
18" MIN.
Heat Shield Spacer
Used to maintain 7/8" spacing where shields do not overlap.
INCHES
(SWHSS)
Dimensions
Code
SWHSS
A
7/8
EXCELiner
RIGID LINER FOR MASONRY CHIMNEYS
EXCELiner
32 Technical Information | EXCELiner
EXCELiner Technical Information
Certification
Applications
EXCELiner is tested and listed by Intertek Testing Services
to the following standards:
EXCELiner is certified as a chimney liner for use on appliances
that burn:
ULC S-635 - Standard for relining existing masonry
chimneys in Canada.
▪▪ Wood
ULC S-640 - Standard for liners for new masonry chimneys
in Canada.
▪▪ Natural or LP Gas
UL 1777 - Standard for liners in new and existing masonry
chimneys in the USA.
Allowable Flue Gas Temperatures
The installation requirements vary depending on which
standard your installation must meet, particularly with
respect to the requirements for insulation and clearance
from the liner. You must insure that your EXCELiner is
installed in accordance with your local building codes.
EXCELiner is available in 5", 5.5", 6", 7" and 8" diameters
EXCELiner is certified for installation in combination
with all certified brands of flexible chimney liner.
▪▪ Oil
Max Continuous
650°C (1200°F)
Brief Forced Firing 925°C (1700°F)
Tested To
1150°C (2100°F)
Clearance to Combustible Materials
The clearance between EXCELiner and surrounding
combustible and non-combustible materials varies with
the type of installation. Please refer to the installation
instructions for specific details for your application.
Construction
Single wall: .016" or .025" stainless steel (all tees are heavy
gauge .025").
Seam: Continuous seam welded.
Insulation: Optional (required for some applications) Foil
backed ceramic liner.
EXCELiner Engineering and Design Considerations
EXCELiner is a fast, cost effective solution
to the following chimney situations:
To repair cracked or damaged clay tile liners. EXCELiner
is designed and approved to replace clay tile liners which
have become cracked from age, misuse, or chimney
fires. EXCELiner can be used to reline structurally sound
masonry chimneys where the liners have deteriorated due
to chimney fires, spalled tiles, moisture damage or eroded
mortar joints.
To improve the safety, performance and efficiency of
wood or gas burning stoves and fireplace inserts. By
reducing the chimney to the correct size for the appliance
EXCELiner improves draft, reduces fuel consumption, and
helps insure consistent operation. There is less creosote
formation in a properly sized flue which decreases the
probability of a chimney fire.
EXCELiner is listed to UL and ULC standards by Intertek
Testing Services to be used as stainless steel liner in a new
chimney, instead of a clay tile liner. Unlike clay tile liners,
EXCELiner can withstand chimney fires without damage
and comes with a lifetime warranty.
EXCELiner is easier to clean
EXCELiner’s smooth surface accumulates less creosote
than a flexible liner and is much easier to clean.
EXCELiner has been tested and
listed to the ULC S-635 ULC
S-640 and UL 1777 chimney liner
standards by INTERTEK.
Listing # 5965
Product Descriptions | EXCELiner33
Lengths
EXCELiner is available in 4’, 3’, 2’ and 1’ lengths. EXCELiner components fasten together with 100%
stainless steel pop rivets wich are supplied with the liner. The holes and slots for the rivets are
factory pre-punched so no drilling is required. The male and female ends are hemmed to make the
liner more rigid and reduce the likelihood of cutting yourself during installation.
(LL4, LL3, LL2 & LL1)
EXCELiner is available in 5", 5.5", 6", 7" and 8" diameter.
INCHES
Length Dimensions
A
11 5/8
23 5/8
35 1/2
47 1/2
LL1
LL2
LL3
LL4
A B
Slip Lengths
B
10 1/4
21 1/4
33 1/8
45 1/8
Slip lengths are available in 3’ and 1’ lengths. Slip lengths are used to adjust the length of the
system without cutting. Note: Slip lengths must be installed above a fixed length or they will not
adjust. They should not be installed immediately above a tee or elbow.
(LLA3 & LLA1)
INCHES
Dimensions
Code
LLA1
LLA3
A
Split Base Tees
A MIN.
1 3/8
1 3/8
A MAX.
11 5/8
35 1/2
EXCELiner tees are made from .025" thick stainless steel. The removable snout is fastened to the
body of the tee with heavy duty stainless steel screws. All 5 1/2", and 6" tees have a 6" diameter
snout so that they can connect to 6" smoke pipe without a reducer. Tee Cap (LTC) not included.
(LT)
INCHES
C
A B
D
Adjustable Snout Tees
Dimensions
Code
5LT
55LT
6LT
7LT
8LT
A
9 3/8
9 7/8
10 3/8
11 3/8
12 3/8
B
8
8 3/8
9
10
11
C
4 5/8
4 7/8
5 1/8
5 5/8
6 1/8
D
3 1/8
3 3/8
3 5/8
4 1/8
4 5/8
E
5 7/8
5 7/8
5 7/8
6 7/8
7 7/8
EXCELiner tees are made from .025" thick stainless steel. The LTA eliminates the difficult job of cutting and
fastening a short horizontal length of liner in the breeching. All 5 1/2", and 6" tees have a 6" diameter
snout so that they can connect to 6" smoke pipe without a reducer. Tee Cap (LTC) not included.
(LTA)
INCHES
C
A B
D
Dimensions
Code
5LTA
55LTA
6LTA
7LTA
8LTA
A
9 3/8
9 7/8
10 3/8
11 3/8
12 3/8
B
8
8 1/2
9
10
11
C
4 5/8
4 7/8
5 1/8
5 5/8
6 1/8
D MIN.
9 5/8
9 7/8
10 1/8
10 5/8
11 1/8
D MAX.
15 3/4
16
16 1/4
16 5/8
17 1/8
E
5 7/8
5 7/8
5 7/8
6 7/8
7 7/8
EXCELiner
EXCELiner Product Descriptions
34 Product Descriptions | EXCELiner
EXCELiner
Tee Cap
Blocks off the open portion of the tee.
INCHES
(LTC)
Dimensions
Code
5LTC
55LTC
6LTC
7LTC
8LTC
Elbows
A
5
5 1/2
6
7
8
B
1
1
1
1
1
The elbows are used when a directional change is required (LEA90 can be adjusted).
(LE30, LE45, LE90 & LEA90)
INCHES
Dimensions
Code
5LE30
55LE30
6LE30
7LE30
8LE30
5LE45
55LE45
6LE45
7LE45
8LE45
5LE90
55LE90
6LE90
7LE90
8LE90
5LEA90
55LEA90
6LEA90
7LEA90
8LEA90
B
A
B
A
A
1 1/4
1 3/8
1 3/8
1 1/2
1 5/8
1 5/8
1 3/4
1 7/8
2
2 1/4
5 1/4
5 1/2
5 3/8
6 1/4
6 3/4
5 7/8
6 1/8
6 3/8
6 7/8
7 3/8
B
2 5/8
2 3/4
2 7/8
3
3 1/8
3
3 1/8
3 1/4
3 1/2
3 5/8
3 7/8
4 1/8
4 3/8
4 7/8
5 3/8
4 1/2
4 3/4
5
5 1/2
6
B
A
Adjustable Flex Adapter Elbow
(LAF90)
This adjustable elbow is designed for use during the installation of an insert. The angle of the elbow
is adjustable to ease installation, and three tabs on the inside of the elbow help secure a flexible
liner in place without tearing.
INCHES
Dimensions
Code
5LAF90
55LAF90
6LAF90
7LAF90
8LAF90
A
8 1/2
8 3/4
9 1/4
9 3/4
10 1/4
B
4 1/2
4 3/4
5
5 1/2
6
Product Descriptions | EXCELiner35
Flex Liner Adapters
Can be used either as an appliance adapter for stainless flex or to connect rigid EXCELiner to flex. The
6LAF5 and 6LAF55 will connect an appliance with a 6" flue outlet to 5" or 5 1/2" flex liner respectively.
(LAF)
INCHES
Dimensions
Code
4LAF
5LAF
55LAF
6LAF
7LAF
8LAF
A
4 1/2
5 3/4
5 3/4
5 3/4
5 3/4
5 3/4
Code
6LAF5
6LAF55
A
4 5/8
3 3/8
B
1 3/4
4 1/4
4 1/4
4 1/4
4 1/4
4 1/4
C
3 7/8
4 7/8
5 3/8
5 7/8
6 7/8
7 7/8
D
4 1/2
5 1/2
6
6 1/2
7 1/2
8 1/2
C
5 7/8
5 7/8
D
5 1/2
6
Dimensions
B
3 1/4
1 3/4
Note: The male end of EXCELiner will fit into most brands of stainless flex
(except for some models of flex which are intentionally made undersize) so
no adapter is generally required when the flex is installed below the rigid.
Increasers and Reducers
Designed to increase or reduce the size of an EXCELiner to accommodate a range of flue sizes,
appliances and installations. Note: Increasing or decreasing chimney size can have a negative
impact of chimney performance and safety. Use these components only when appropriate.
(LI & LR)
B
Increaser
INCHES
Increaser Dimensions
Code
LI56
LI556
LI67
LI78
A
Reducer
B
A
4 7/8
5 3/8
5 7/8
6 7/8
B
6
6
7
8
C
3 1/4
3 1/4
3 1/4
3 1/4
Reducer Dimensions
Code
LR65
LR655
LR76
LR87
A
Insulated Wall Thimbles
A
5 7/8
5 7/8
6 7/8
7 7/8
B
5
5 1/2
6
7
C
3
3
3
3
The ITH is tested and listed to connect through a combustible wall into a masonry chimney. It is
adjustable to accommodate wall thickness up to 10" and can be combined with any UL listed liner
system (ULC S-635, ULC S-640 or UL 1777). Not available in 5.5"
(ITH)
INCHES
Dimensions
Code
5ITH
6ITH
7ITH
8ITH
ITH Extension
A MIN.
7 1/2
7 1/2
7 1/2
7 1/2
A MAX.
13
13
13
13
B
20
20
20
20
C
8 3/4
9 3/4
10 3/4
11 3/4
UL Listed extension for the Insulated Wall Thimble (ITH). Increases the total depth of the ITH to 24".
(ITHE)
INCHES
B
C
Dimensions
A
Code
5ITHE
6ITHE
7ITHE
8ITHE
A
4 7/8
5 7/8
6 7/8
7 7/8
B
13 1/2
13 1/2
13 1/2
13 1/2
C
8 7/16
9 7/16
10 7/16
11 7/16
EXCELiner
NEW
36 Product Descriptions | EXCELiner
EXCELiner
Rain Caps
(LCR, LCD)
EXCELiner rain caps are made entirely of type 304 stainless steel. The top is held in place with four
wing nuts on the regular (LCR) and deluxe (LCD) rain caps for easy removal and cleaning without the
need to remove the rain cap itself. The deluxe cap has a stainless steel band.
INCHES
LCR
LCD
Top Supports
(LSA, LSAL, LSAG & LSAGL)
Dimensions
Code
5 LCR & LCD
55 LCR & LCD
6 LCR & LCD
7 LCR & LCD
8 LCR & LCD
A
13
13
13
13
13
B
3 7/8
4
4 1/8
4 1/4
4 3/8
The top support is designed to seal off the top of the liner system and support the vertical liner.
It is available in either stainless steel or galvalume. There are two base sizes available - 16" X 16"
and 24" X 24".
INCHES
Dimensions
Code
LSA
LSAL
LSAG
LSAGL
Base Support
A
4
4
4
4
B
4 1/2
4 1/2
4 1/2
4 1/2
C
16
24
16
24
The base support is designed to seal and support a liner system. It is available in galvalume only.
(LSB)
NEW
Offset Box
(FOB)
For tight insert installations that need to be offset quickly in order to align with the flue. The Offset
Box is adjustable in length and has a clean-out port with removable thumb screws.
INCHES
Dimensions
Code
6FOB
8FOB
A
5 7/8
7 7/8
B
6 3/8
8 3/8
C
2 1/8
3 3/8
D MIN.
15 5/8
17 7/8
D MAX.
20 1/4
21 3/8
E MIN.
6 3/8
6 5/8
E MAX.
11 7/8
10 1/8
Model RIS
ALL FUEL, INSULATED CHIMNEY SYSTEM 10" - 24"
Model RIS
38 Technical Information | Model RIS
Model RIS Technical Information
Certification
Allowable Flue Gas Temperatures
Model RIS is tested and listed by Intertek Testing Services
to the following standard:
Max Continuous
540°C (1000°F)
Brief Forced Firing 760°C (1400°F)
Tested To
1150°C (2100°F)
UL 103HT - The standard for solid and liquid fuel chimneys.
Applications
RIS chimney is suitable for use on appliances that burn:
Clearance to Combustible Materials
Model RIS is certified for 2" clearance to combustible
materials.
▪▪ Wood
▪▪ Oil
▪▪ Coal
▪▪ Natural or LP Gas
▪▪ Charcoal
Model RIS is certified to vent wood burning stoves, fireplaces
and residential furnaces. In addition, there are a number of
RIS components specifically designed and certified to vent
large open masonry fireplaces burning wood and/or gas.
There are also specific components designed to extend
masonry chimneys and repair earthquake damaged masonry
chimneys.
Note for customers in Canada: Model RIS is not certified
to the ULC S-629 Standard. Do not install an RIS system
on a wood fireplace without first contacting your
local authority for approval. ICC can provide complete
engineering services (sizing, material selection, installation
recommendations, drawings etc.) to assist you in obtaining
approval. However, we can not guarantee that it will be
accepted in all cases. If you have a large fireplace project
you would like to quote on please be sure to contact us in
advance so we can work with your local engineer, architect
and building authority.
Construction
Flue: .018" - .025", stainless steel.
Casing: .018" - .025", stainless steel or
.018" - .025" galvalume steel.
Seam: Interior and exterior seams are continuous
seam welded.
Insulation: Thermoplus continuous blanket.
Wall thickness: 1"
See page 69 of this catalog for recommended chimney
sizing for masonry fireplaces.
Note: There are some components of RIS chimney that are
available in 10" and 12" diameter only. The parts include
the Roof Top Shield (RTS), Insulated Angle Wall Radiation
Shields (45° & 30°), Chimney Top Damper (ETD) and Metal
Roof Flashings (RMFA, RMFB, RMFC). Some of these parts
are specific to particular fireplaces and not described in
the catalog.
Model RIS has been tested
and listed to the UL 103HT
chimney standards by
INTERTEK.
Listing #5965
Product Descriptions | Model RIS39
Lengths
(RIL)
RIS is available in 12", 18", 24" and 48" lengths. Deduct 1 1/2" from overall length of each length to
determine the actual installed length.
Diameters 10" – 14" have a 430 stainless steel exterior like EXCEL.
Diameters 16" – 24" have either a galvalume or 304 stainless steel exterior.
Adjustable Lengths
(RILA)
12" and 24" adjustable lengths are available. The 12" can be adjusted from 7 1/2 to 10". The 24" can
be adjusted from 13 1/2 to 22". Deduct 1 1/2" from overall length to determine the actual installed
length. Note: Adjustable lengths must be installed above a fixed length or they will not work. They
should not be installed immediately above a round or square support, tee or elbow.
Insulated Tees
Designed to connect horizontal and vertical lengths of the chimney. Does not include a tee cap (RITC).
INCHES
(RIT)
Dimensions
PIPE I.D.
10
12
14
16
18
20
22
24
Elbows
A
16 3/4
18 3/4
20 3/4
22 3/4
24 3/4
26 3/4
28 3/4
30 3/4
B
9
10
11
12
13
14
15
16
C
9
10
11
12
13
14
15
16
Used when a directional change is required. Note: 45° elbows are approved for use in Canada only.
INCHES
(RIE15, RIE30 & RIE45)
Dimensions
PIPE I.D.
10
12
14
16
18
20
22
24
15°
A
6 7/8
7 3/8
7 7/8
8 3/8
8 7/8
9 3/8
9 7/8
10 3/8
B
3/4
7/8
7/8
1
1
1 1/8
1 1/8
1 1/4
30°
A
8 1/2
9
9 1/2
10
10 1/2
11
11 1/2
12
B
1 7/8
2
2 1/8
2 1/4
2 1/2
2 5/8
2 3/4
2 7/8
45° CANADA ONLY
A
B
9 3/8
2 3/4
10
3 1/4
10 3/4
3 3/4
11 1/2
4 1/4
12 1/4
4 5/8
12 7/8
5 1/8
13 1/2
5 5/8
14 1/4
6
Model RIS
Model RIS Product Descriptions
40 Product Descriptions | Model RIS
Model RIS
Chimney Top Damper
Currently available in 10" and 12" diameter only. Adding this “Top Damper” to a system seals it
right at the top of the chimney. The “Chimney Top Damper” is placed directly below the cap and is
designed to prevent any cold air infiltration into the house through the chimney. It functions on a
chain that hangs down to the firebox and comes with 30’ of wire.
(RCTD)
INCHES
Dimensions
Code
10RCTD
12RCTD
Radiation Shield
(RRS)
Used when the chimney passes through a
combustible floor or ceiling.
O.D. + 2"
B
12
14
Anchor Plate
(RAP)
C
12
12
D
10 1/4
10 1/4
Is used to connect an appliance (such as a masonry
fireplace or heater) to an RIS chimney.
O.D. + 4"
12"
12"
O.D. + 6"
O.D. + 6"
10" RIS
≥ 12" RIS
Anchor Plate Damper
Combines the anchor plate with a heavy gauge stainless steel damper. The RAPD simplifies masonry
fireplace construction, reduces installation cost and provides a superior seal.
(RAPD, RAPD2)
(RAPD)
(RAPD2)
Rain Caps
(RRC)
(RRC)
A
10
12
(RRCW)
The RIS rain cap is constructed entirely of stainless steel. It is designed to provide good protection
from wind and rain while incorporating small size and a low profile. An optional wind/rain shield is
available in 10" – 24" diameter.
Note: We do not recommend the use of untested, unlisted rain caps or shrouds. In some cases it is
possible to create an unsafe installation simply by using an aftermarket shroud. If you choose to do
so you must terminate the chimney with an ICC Rain Cap Base (RRCB). The RRCB closes off the top
of the chimney to prevent moisture from entering the insulation.
Spark Screen
(RRCS)
An optional spark screen is available for installations where sparks can pose a safety problem.
Product Descriptions | Model RIS41
Roof Flashings
Flashings include a storm collar
(RMFA, RMFB, RMFC) These flashings are specifically designed for metal roofs and greatly
simplify metal roof installations. They are made from galvalume steel only.
INCHES
(F)
Ø
10
12
14
16
18
20
22
24
Pitch 0 - 2/12
A
17 15/16
19 15/16
21 15/16
23 15/16
25 15/16
27 15/16
29 15/16
31 15/16
(FA)
B
28 x 28
30 x 30
32 x 32
34 x 34
36 x 36
38 x 38
40 x 40
42 x 42
Pitch 1/12 - 7/12
A
16 7/8 - 17 7/8
19 1/4 - 20 1/4
21 1/2 - 22 5/8
23 3/4 - 25
27 3/8 - 26
29 3/4 - 28 1/4
31 7/8 - 33 5/8
32 1/8 - 38 1/2
(FB)
B
28 x 28
30 x 30
32 x 32
35 x 35
37 x 37
38 x 40
42 x 44
42 x 48
Pitch 8/12 - 12/12
A
19 1/8 - 23
21 3/4 - 26 1/8
24 - 29 1/8
27 - 32 1/2
29 1/8 - 35 1/8
32 - 38 3/8
n/a
32 1/8 - 38 1/2
B
28 x 33
32 x 36
34 x 40
37 x 42
40 x 45
42 x 48
n/a
48 x 51
Metal Roof Flashings (10" & 12" dia. Only)
Metal Roof Flashing
US Patent #7114301
Can Patent #2460044
Wall Support
Wall Band
(RWB)
Roof Support
(RSR)
Ventilation
ventilated
ventilated
ventilated
Fits Pitch Range
1/12 - 7/12
8/12 - 12/12
12/12 - 21/12
Designed to support a vertical chimney on a wall. There are two styles of wall support, one for 10"
& 12" diameter RIS and one for all other diameters.
(RWS)
RWS for 10" & 12" diameters
Code
RMFA
RMFB
RMFC
RWS for all other sizes
Used on vertical or horizontal runs of chimney
to stabilize the chimney. The maximum distance
between wall bands is 8’.
Offset Support
The roof support is used above an offset, to
provide additional support when the chimney
height exceeds the primary support capacity.
Roof Brace
(ROS)
(RRB)
The offset support is primarily used to re-support
the chimney above an offset. However it may
also be used to provide additional support when
the chimney height exceeds the capacity of the
primary support.
Designed to provide a lateral support for the
chinmney above a roof. The roof brace must be
fastened solidly into a structural member.
Model RIS
(RF, RFA & RFB) Used to provide weather protection where the chimney penetrates the roof.
Three models are available to accommodate various roof pitches. The storm collar (RSC) is included.
42 Offset Tables | Model RIS
Model RIS
Locking Band
All RIS insulated components are designed
to be fastened together with the stainless
steel screws provided with each part. In some
cases, it may be desirable to install a locking
band for aesthetic purposes. The locking
band is designed to overlap the two beads
immediately above and below the chimney
joint and fastens with a 1/4" bolt. All screws
are required even when the locking band is
installed. Available in stainless steel and
galvalume.
(RSLB & RGLB)
Roof Top Shield
Required for Renaissance Fireplace installations.
(RTS)
24"
Model RIS Offset Tables
RIS Offset Table 10 to 16 inches
LENGTH
BETWEEN
ELBOWS
2 X 15°
RIS Offset Table 18 to 24 inches
2 X 30°
2 X 45°
RISE
OFFSET
RISE
OFFSET
RISE
OFFSET
NO LENGTH
11 7/8
1 5/8
14 1/8
3 3/4
15 7/8
6 5/8
12" Length
22 1/4
4 3/8
23 3/8
9 1/8
23 1/2
14 1/8
24" Length
33 7/8
7 1/2
33 3/4
15 1/8
32
48" Length
57
13 5/8
54 5/8
27 1/8
48" + 12"
67 3/8
16 1/2
63 7/8
48" + 24"
79
19 1/2
48"+24"+12"
89 3/8
48" + 48"
LENGTH
BETWEEN
ELBOWS
2 X 15°
2 X 30°
2 X 45°
RISE
OFFSET
RISE
OFFSET
RISE
OFFSET
NO LENGTH
13 7/8
1 7/8
17 7/8
4 3/4
21 3/8
8 7/8
12" Length
24 1/4
4 5/8
27 1/8
10 1/8
29
16 1/2
22 5/8
24" Length
35 7/8
7 3/4
37 1/2
16 1/8
37 1/2
25
48 7/8
39 5/8
48" Length
59
13 7/8
58 1/4
28 1/8
54 1/8
41 7/8
32 1/2
56 1/2
47 1/4
48" + 12"
69 3/8
16 3/4
67 5/8
33 1/2
62 1/8
49 1/2
74 1/4
38 1/2
65
55 3/4
48" + 24"
81
19 3/4
78
39 1/2
70 5/8
58
22 3/8
83 5/8
43 7/8
72 5/8
63 3/8
48"+24"+12"
91 3/8
22 5/8
87 3/8
44 7/8
78 1/8
65 5/8
102 1/4
25 3/4
95
50 1/2
82
72 3/4
48" + 48"
104 1/8
26
98 3/4
51 1/2
87 1/2
75
NO LENGTH
11 7/8
1 5/8
15
4
17 1/8
7 1/8
NO LENGTH
13 7/8
1 7/8
19 1/4
5 1/8
23 1/8
9 5/8
12" Length
22 1/4
4 3/8
24 3/8
9 3/8
24 3/4
14 3/4
12" Length
24 1/4
4 5/8
28 1/2
10 1/2
30 3/4
17 1/8
24" Length
33 7/8
7 1/2
34 3/4
15 3/8
33 1/4
23 1/4
24" Length
35 7/8
7 3/4
38 7/8
16 1/2
39 1/8
25 5/8
48" Length
57
13 5/8
55 1/2
27 3/8
50 1/4
40 1/8
48" Length
59
13 7/8
59 3/4
28 1/2
56 1/4
42 5/8
48" + 12"
67 3/8
16 1/2
64 7/8
32 3/4
57 7/8
47 3/4
48" + 12"
69 3/8
16 3/4
69
33 7/8
63 3/4
50 1/4
48" + 24"
79
19 1/2
75 1/4
38 3/4
66 1/4
56 1/4
48" + 24"
81
19 3/4
79 3/8
39 7/8
72 1/4
58 3/4
48"+24"+12"
89 3/8
22 3/8
84 1/2
44 1/8
73 7/8
63 7/8
48"+24"+12"
91 3/8
22 5/8
88 3/4
45 1/4
79 7/8
66 3/8
48" + 48"
102 1/4
25 3/4
96
50 3/4
83 1/4
73 1/4
48" + 48"
104 1/8
26
100 1/8
51 7/8
89 1/4
75 3/4
10 INCH Ø
18 INCH Ø
12 INCH Ø
20 INCH Ø
14 INCH Ø
22 INCH Ø
NO LENGTH
12 7/8
1 3/4
16
4 1/4
18 7/8
7 3/4
NO LENGTH
14 7/8
2
20 1/8
5 3/8
24
9 7/8
12" Length
23 1/4
4 1/2
25 1/4
9 5/8
26 1/2
15 3/8
12" Length
25 1/4
4 3/4
29 1/2
10 3/4
31 5/8
17 1/2
24" Length
34 7/8
7 5/8
35 5/8
15 5/8
35
23 7/8
24" Length
36 7/8
7 7/8
39 7/8
16 3/4
40 1/8
26
48" Length
58
13 3/4
56 1/2
27 5/8
51 7/8
40 7/8
48" Length
60
14
60 5/8
28 3/4
57
43
48" + 12"
68 3/8
16 5/8
65 3/4
33
59 1/2
48 1/2
48" + 12"
70 3/8
16 7/8
70
34 1/8
64 5/8
50 5/8
48" + 24"
80
19 5/8
76 1/8
39
68
57
48" + 24"
82
20
80 3/8
40 1/8
73 1/8
59 1/8
48"+24"+12"
90 3/8
22 1/2
85 1/2
44 3/8
75 5/8
64 1/2
48"+24"+12"
92 3/8
22 3/4
89 5/8
45 1/2
80 3/4
66 5/8
48" + 48"
103 1/8
25 7/8
96 5/8
51
85
73 7/8
48" + 48"
105 1/8
26 1/8
101 1/8
52 1/8
90 1/8
76
16 INCH Ø
24 INCH Ø
NO LENGTH
12 7/8
1 3/4
16 7/8
4 1/2
20 1/8
8 3/8
NO LENGTH
14 7/8
2
21 1/8
5 5/8
25 3/4
10 5/8
12" Length
23 1/4
4 1/2
26 1/4
9 7/8
27 3/4
16
12" Length
25 1/4
4 3/4
30 3/8
11
33 1/4
18 1/4
24" Length
34 7/8
7 5/8
36 5/8
15 7/8
36 1/4
24 3/8
24" Length
36 7/8
7 7/8
40 3/4
17
41 3/4
26 3/4
48" Length
58
13 3/4
57 3/8
27 7/8
53 1/4
41 3/8
48" Length
60
14
61 5/8
29
58 3/4
43 3/4
48" + 12"
68 3/8
16 5/8
66 5/8
33 1/4
60 3/4
49
48" + 12"
70 3/8
16 7/8
70 7/8
34 3/8
66 3/8
51 1/4
48" + 24"
80
19 5/8
77 1/8
39 1/4
69 1/4
57 1/2
48" + 24"
82
20
81 1/4
40 3/8
74 7/8
59 3/4
48"+24"+12"
90 3/8
22 1/2
86 3/8
44 5/8
76 7/8
65 1/8
48"+24"+12"
92 3/8
22 3/4
90 5/8
45 3/4
82 1/2
67 3/8
48" + 48"
103 1/8
25 7/8
97 7/8
51 1/4
86 1/4
74 1/2
48" + 48"
105 1/8
26 1/8
102
52 3/8
91 3/4
76 3/4
All measurements are in inches
All measurements are in inches
EXCELPellet
PELLET AND BIOFUEL VENTING SYSTEM
EXCELPellet
44 Technical Information | EXCELPellet
EXCELPellet Technical Information
Certification
Allowable Flue Gas Temperatures
EXCELPellet has been tested and listed to UL 641 and ULC
S609 by Intertek Testing Services.
Max Continuous Tested To
Applications
Clearance to Combustible Materials
EXCELPellet is certified as a chimney liner for use on
appliances that burn:
EXCELPellet is certified for 1" clearance to combustible
materials.
▪▪ Wood
300°C (572°F)
927°C (1700 °F)
▪▪ Agricultural products
Construction
▪▪ Natural or LP Gas
Flue: .016" laser welded stainless steel.
Casing: .019" laser welded Galvalume steel or .019" laser
welded satin coat steel (painted)
Paint: Forrest “Stove Bright” flat black.
Insulation: 3/8" Air Space
Gasket: Silicone Rubber
EXCELPellet Engineering and Design Considerations
We suggest that your pellet system be designed with
a vertical rise. This is not a requirement but will help
the stove to vent combustion products in the case
of a power failure.
Keeping the horizontal run and number of elbows
to a minimum will reduce the cost of your installation and
improve performance.
EXCELPellet is manufactured using specialized machinery
which makes it possible to maintain strict tolerances
between components. This precision permits the use
of a factory installed silicone gasket and eliminates
the need for field application of silicone.
This unique factory installed silicone rubber gasket solves
two major pellet venting problems:
Although not required we recommend that terminations
be installed 12" away from the wall to reduce the
potential for smoke staining on outside walls. Refer
to your stove manual for exact dimensions.
▪▪ The gasket seals perfectly so there is no need
for sealant application in the field. This speeds up
installation, simplifies clean up, facilitates painting
and eliminates callbacks.
Do not install a vent smaller in diameter than the flue
outlet on the stove.
▪▪ Not only do all parts assemble easily, they can be
disassembled and reassembled just as easily making
routine maintenance much easier.
EXCELPellet must be installed according to the installation
instructions (available from your dealer upon purchase
of support or on our web site) have drawings of typical
installations and detailed installation information.
EXCELPellet has a smooth attractive Black painted or
Galvalume steel exterior. Galvalume is corrosion resistant
and requires very little preparation for painting.
4005717
Typical Installations | EXCELPellet45
EXCELPellet
EXCELPellet Typical Installations
NOTE: The following information are not to be used as installation
instructions. Please refer to the detailed EXCELPellet installation
instructions for complete details on your specific application.
All measurements are in inches
Inside Diameter
Outside Diameter
Weight/Foot (lb/ft.)
3 Inch
4 Inch
3 3/4"
1.3
4 3/4"
1.6
Jet Cap
6 3/4" x 6 3/4"
6 3/4" x 6 3/4"
7 1/2" x 7 1/2"
or 7 1/2" round
6" to 8" dia.
Elbow
Rough Opening Required:
Supports (PSA, PSF)
Supports (PSS)
Wall Thimble (PWT)
Masonry Chimney Adapter (PAM)
5 3/4" x 5 3/4"
6 3/4" x 6 3/4"
6 1/2" x 6 1/2"
or 6 1/2" round
6" to 8" dia.
Wall Support
Length
Maximum Support capacity
Ceiling Supports (PSA, PSF)
Ceiling Support (PSS)
Wall Support (PSW)
30 feet
37 feet
21 feet
25 feet
30 feet
17 feet
Insulated
Wall Thimble
Stove Adapter
Vertical Cap
Storm Collar
Clean-out Tee
Flashing
Horizontal Cap
Insulated
Wall Thimble
Storm Collar
Elbow
Length
Support /
Radiation Shield
Clean-out Length
Length
Stove
Adapter
3" to 4" Stove
Adapter Tee
3" to 4" Tee
EXCELPellet
46 Product Descriptions | EXCELPellet
EXCELPellet Product Descriptions
Lengths
48", 36", 24", 16", 12", 5" & 6", 16" slip lengths, all lengths are available in Galvalume or Black
exterior.
(PL5, PL5B, PLA6, PLA6B, PL16, PL16B,
PLA16, PLA16B, PL1, PL1B, PL2, PL2B,
PL3, PL3B, PL4, PL4B)
INCHES
Length Dimensions
A
B
Lengths
3"
3
3 3/4
4"
4
4 3/4
5"
C
4 7/8
D
3 1/8
12"
16"
24"
36"
48"
11 7/8
15 7/8
23 7/8
35 7/8
47 7/8
10 1/8
14 1/8
22 1/8
34 1/8
46 1/8
6" & 16" Slip Length Dimensions
A
B
Lengths
C
D
Clean-Out Length
3"
2 7/8
3 7/8
6"
7 3/4
6
16"
15 3/4
14
4"
3 7/8
4 7/8
6"
7 3/4
6
16"
15 3/4
14
The removable casing allows access to the inside of the flue for easy cleaning. The Clean-Out length
can be in any location as a substitute for a standard length.
(PCOL)
INCHES
Clean-Out Length Dimensions
3"
3 1/16
3 5/8
11 7/8
10 1/8
4 3/16
3 3/16
A
B
C
D
E
F
Tees
4"
4 1/16
4 5/8
11 7/8
10 1/8
4 1/8
2 1/2
The tee cap incorporates a silicone gasket making it easy to remove for cleaning. All tees are
available in Galvalume or Black exterior. Short snout places vent closer to stove. Tee cap included.
(PT, PTB, 3PT4, 3PT4B)
INCHES
Tee Dimensions
A
B
C
D
Stove Adapter Tee
3"
3
3 3/4
8 3/4
4 1/8
4"
4
4 3/4
9 3/4
4 5/8
3" to 4"
3
4 3/4
8 3/4
4 5/8
These Tees can be installed directly to the Stove without the need for a stove adapter. Tee cap included.
INCHES
(3PAT3, 3PAT3B, 3PAT4, 3PAT4B)
Stove Adapter Tee Dimensions
B
C
A
D
3"
3" to 4"
A
3
3
B
C
D
E
3 3/4
8 3/4
3 7/8
5/8
4 3/4
8 3/4
4 3/8
5/8
Product Descriptions | EXCELPellet47
Clean-Out Tee
Allows easy access to the horizontal run of a system for cleaning. Tee cap included.
Clean Out Tee Dimensions
3"
3
3 3/4
8 3/4
4 1/8
A
B
C
D
Tee Cap
NEW
If a replacement tee cap is required. Two versions of the tee cap exist depending on the style of
your tee. The PTC is held in place with screws, the PTC1 is held with a bolt at the bottom of the cap.
(PTC, PTC1)
PTC
Elbows
(PE45, PE45B, PE90, PE90B)
4"
4
4 3/4
9 3/4
4 5/8
PTC1
Small radius to make installations in tight spaces easier. 45° and 90° available, all elbows are
available in Galvalume or Black exterior.
INCHES
Dimensions
A
2 7/8
3
4 11/16
5 1/4
3PE45
4PE45
3PE90
4PE90
NEW
Slip Elbow
(PE90S, PE90SB)
B
2 7/8
3
4 11/16
5 1/4
The vertical portion of the slip elbow slides over a standard pellet length just like a slip section. This
eliminates the need for a separate slip piece.
INCHES
Dimensions
Code
3PE90S
4PE90S
Clean-Out Elbow
(PCOE)
A max.
10 3/4
11 1/4
A min.
2 7/8
3 3/8
B
3
3 1/2
The removable casing allows access to the inside of the flue for easy cleaning. Typically used for
“up and out” installations.
INCHES
Dimensions
A
B
C
D
3"
3
4 1/2
12 3/8
9 3/8
4"
4
5 1/2
13 3/8
9 7/8
EXCELPellet
INCHES
(PCOT)
REDESIGNED
EXCELPellet
48 Product Descriptions | EXCELPellet
3" - 4" Tapered Increaser
(3PIT4, 3PIT4B)
Increase from 3" to 4" diameter at any point in the system.
INCHES
Dimensions
A
B
C
D
E
Insulated Wall Thimble
(PWT)
4
4 3/4
3
3 5/8
6
Telescopes to accommodate wall thicknesses from 5" to 10". It is fully insulated to maintain
insulation integrity and fits tightly to prevent heat loss. The 3" requires a 6 1/2" X 6 1/2" framed
opening; the 4" requires a 7 1/2" X 7 1/2" framed opening. A template for EXCELPellet wall thimbles
can be purchased to simply installation (PTMP).
INCHES
Dimensions
A
B
C
D
E
Wall Thimble with Integrated
Outside Air (PWTOI)
3"
3 7/8
9 1/4
6 3/8
min. 5 - max. 10
1 1/2
4"
4 7/8
10 1/4
7 3/8
1 1/2
Simplifies a fresh air connection by integrating it into the same conduit as the wall thimble.
This component is fully insulated through the wall and on the inside wall to prevent cold air or
condensation in the home. Includes 10' of aluminum flex and 3' flex insulation.
INCHES
Dimensions
A
B
3"
3 7/8
2 7/8
C
15
D
E
F
G
Wall Thimble with Outside
Air Channel (PWTOC)
4"
4 7/8
2 7/8
16
min. 6 1/2 - max. 11 1/2
11 1/4
6 5/8
1 1/2
12 1/4
7 5/8
1 1/2
Functions similarly to the PWTOI, but designed for “up and out” installations (e.g. basement). The
outside air channel is adjustable for height and can be painted any color to match the décor. Includes
10' of aluminum flex and 3' flex insulation.
INCHES
Dimensions
A
B
3"
3 7/8
2 7/8
C
Adj. 44 – 68
D
E
F
G
Wall Thimble Extension
(PWTE)
4"
4 7/8
2 7/8
Adj. 45 – 68
min. 6 1/2 - max. 11 1/2
11 1/4
6 5/8
1 1/2
12 1/4
7 5/8
1 1/2
UL Listed Wall Thimble insulated extensions. They install easily and will allow wall thimbles to fit
walls up to 20 3/4" thick.
INCHES
Dimensions
A
B
C
3"
4 1/8
6 1/4
5 3/4 to 15
4"
5 1/4
7 1/4
Product Descriptions | EXCELPellet49
(PSA)
Rated to support up to 30’ (3") or 25’ (4") of venting where it passes through a floor or ceiling. It
telescopes from 12" to 23" to keep insulation and debris away from the vent.
INCHES
Dimensions
A
B
C
D
Square Support/Radiation Shield
(PSS)
3"
3 7/8
9 1/4
5 3/4
4"
4 7/8
9 1/4
6 3/4
min. 12 - max. 23
Rated to support up to 37’ (3") or 30’ (4") of venting where it passes through an insulated or
un-insulated ceiling. It is particularly suitable for cathedral and drop ceilings.
INCHES
Dimensions
A
B
C
D
Adjustable Wall Support
(PSW)
3"
3 7/8
10 3/4
6 5/8
16
4"
4 7/8
10 3/4
6 5/8
16
Rated to support up to 21’ (3") or 17’ (4") of venting. Fits 3" and 4" diameters. It adjusts easily to
provide from 1" to 5" of clearance to the wall.
INCHES
Dimensions
A
B
C
D
Masonry Adapter
(PAM)
3"
3 3/4
7 1/2
4 1/4
2 3/4
4"
4 3/4
7 1/2
4 1/4
2 3/4
Provides a tight, positive transition to a masonry chimney. Fits existing masonry thimbles up to 8"
in diameter.
INCHES
Dimensions
A
B
C
D
Type A Chimney Adapter
(PAA5, PAA6, PAA7, PAA8)
3"
3 15/16
9 1/2
5 7/8
3 3/4
4"
4 15/16
9 1/2
5 7/8
3 3/4
Provides a positive sealed connection between EXCELPellet and type A chimneys. Models to connect
3" or 4" pellet vent to 6", 7’ or 8" type A.
INCHES
Dimensions
A
B
C
D
3"
3 3/4
4"
4 3/4
5, 6, 7 or 8
2
2 1/4
2
2 1/4
EXCELPellet
Ceiling Support/Radiation Shield
EXCELPellet
50 Product Descriptions | EXCELPellet
NEW
Type A Chimney
Reline Adapter
Permits re-lining of an existing pre-fab chimney with EXCELPellet or an approved flexible liner.
Available to fit 6", 7" or 8" chimneys with 3" or 4" venting. Use the universal Chimney Adapter Cap
(PCA) at the top.
(PAX6, PAX7, PAX8)
INCHES
Dimensions
3"
3 7/8
A
B
C
Chimney Adapter Cap
4"
4 7/8
6, 7 or 8
2 3/4
2 3/4
This cap will fit any brand of chimney with up to an 8" I.D. It’s connects to EXCELPellet or a flexible
liner used to re-line the existing chimney. Available in 3" or 4".
(PCA)
INCHES
Dimensions
3"
3 3/4
13 1/2
5
A
B
C
NEW
Female Flex Adapter
Provides a sealed connection where a flexible liner is installed above an EXCELPellet system.
INCHES
(PAF, 3PAF4, PAF5, PAF55, PAF6)
Dimensions
Code
3PAF
3PAF4
3PAF5
3PAF55
3PAF6
4PAF
4PAF5
4PAF55
4PAF6
Flex Adapter Tee
4"
4 3/4
13 1/2
5
A
3
3
3
3
3
4
4
4
4
B
3 3/4
3 3/4
3 3/4
3 3/4
3 3/4
4 3/4
4 3/4
4 3/4
4 3/4
C
5
2 3/4
3 1/2
3 1/2
3 1/2
5
3 1/2
3 1/2
3 1/2
D
3 5/8
4 5/8
5 1/2
6
6 1/2
4 5/8
5 1/2
6
6 1/2
For pellet stove installations that are vented into a masonry chimney. Connects EXCELPellet to a 4"
flexible liner and has a removable twist mouth that is available in 3" or 4". Use in combination with
the Masonry Adapter (PAM).
(3PATF4, 4PATF4)
INCHES
Dimensions
A
B
C
D
E
Pellet / Liner 5" Adapter
(PAL5)
3"
4 9/16
2 7/8
6 3/4
4 5/8
10 3/4
4"
4 9/16
3 7/8
7 3/4
4 5/8
10 3/4
Provides a sealed connection where a rigid liner is installed above an EXCELPellet system.
INCHES
Dimensions
A
B
C
D
3"
3
3 3/4
5
4 1/4
4"
4
4 3/4
5
5 5/8
Product Descriptions | EXCELPellet51
Universal adapter fits both large OD flue collars (e.g.: Harman) and small OD flue collars. The stove
adapter fastens permanently to the stove but can be easily disconnected from the rest of the vent
to simplify cleaning. Available in Galvalume or Black exterior.
(PAS, PASB)
INCHES
Dimensions
A
B
C
Tapered Stove Adapter
(3PI4, 3PI4B)
3"
3
3 5/8
4"
4
4 5/8
3 3/8
Universal Stove adapter that increases diameter from 3" to 4".
INCHES
Dimensions
A
B
C
D
E
Quick Disconnect
Stove Adapter (PAQ)
4
4 3/4
3
3 5/8
6
Makes cleaning and servicing pellet stoves dramatically easier. This stove adapter comes apart at
the center by undoing two thumb screws. With the PAQ installed, there is no need to take lengths
apart for cleaning.
INCHES
Dimensions
A
B
C
D
Harman Stove Adapter
(PASH, PASH6)
3"
3
5 3/8
3 5/8
4 3/4
4"
4
5 3/8
3 5/8
5 3/4
Bolts directly to Harman stoves and does not require silicone. Available in two lengths to accommodate stoves with extended hoppers. Includes a Harman Style Gasket (HG).
INCHES
Dimensions
A
B
C
NEW
Harman Style Gaskets
(HG)
PASH
3
2 7/8
1 1/8
PASH6
3
6 3/8
4 5/8
Replacement gaskets for the Harman Stove Adapter, comes in packs of 5.
EXCELPellet
Stove Adapter
EXCELPellet
52 Product Descriptions | EXCELPellet
Adjustable Jet Cap
Can be rotated to direct hot flue gasses away from bushes or other things in proximity to the exhaust.
INCHES
(PCJ)
Dimensions
A
B
C
Horizontal Cap
3"
9 3/8
5 1/2
3 3/4
4"
9 3/4
5 7/8
4 3/4
Directs and accelerates flue gasses away from the house reducing the possibility of “moustache
effect” from smoke accumulation.
(PCH)
INCHES
Dimensions
A
B
C
Economy Cap
3"
5
6 1/4
3
4"
6
8
4
Can be installed straight or at a 45° angle to direct hot flue gasses away from bushes and other
objects. Made of single wall stainless steel. Does not include a screen.
(PCE)
INCHES
Dimensions
A
B
C
Spark Screen
3"
3 11/16
3 9/16
5 5/8
4"
4 1/16
4
6 1/16
A stainless steel spark screen that fits any standard length or elbow to be used as a termination.
Also fits Economy Cap (PCE).
(PCS)
INCHES
Dimensions
A
B
Vertical Rain Cap (PCR)
Rain/Wind Shield (PRCW)
Vertical rain cap (PCR)
with rain/wind shield (PRCW)
4"
4 3/4
1 7/8
INCHES
Dimensions
A
B
C
D
E
Vertical rain cap (PCR)
3"
3 3/4
1 7/8
3"
3
8
3 7/8
11
3 7/8
4"
4
9
3 7/8
11
3 7/8
Product Descriptions | EXCELPellet53
(PCT)
A
B
C
D
E
Universal
Flashing for
Traditional Cap
(CTF)
NEW
Clay Tile
Flashing for
Traditional Cap
(CTFC)
NEW
INCHES
Dimensions
Hose Clamp Bracket
6 1/2
2 3/4
3 3/4
16 1/2
12
REDESIGNED
NEW
Certified for pellet appliances in a masonry chimney. Requires a flashing (CTF, or CTFC). The optional
Wind / Rain Shield (CTS) can improve performance in extreme wind conditions.
Made of galvalume, this flat flashing base is easy to cut, bend, or simply silicone to the top of a
masonry chimney.
INCHES
Dimensions
A
B
C
11 3/4
7 1/4
20
Made of galvalume and designed to fit onto a clay tile flue. Optional Hose Clamp Bracket (HC) can
be used or it can be secured in the method of your choice.
INCHES
Dimensions
A
B
C
D
11 3/4
7 1/4
13 3/4
1 1/2
Heavy duty hose clamp and two mounting brackets for the Clay Tile Flashings (MFC and CTFC).
(HC)
68" long
Flashings
INCHES
Flashing Dimensions
(PF, PFA, PFB)
A
B
C
D
Flat
3"
4
8 1/16
15 7/8
15 7/8
4"
5
8 1/16
15 7/8
15 7/8
EXCELPellet
Traditional
Masonry Adapter
Cap
1/12 - 7/12
3"
4
9 3/4
18
15 15/16
4"
5
10
18
15 15/16
8/12 - 12/12
3"
4
14 1/4
22 1/2
18
4"
5
15 5/16
24
18
Includes a storm collar
EXCELPellet
54 Offset Tables | EXCELPellet
Storm Collars
INCHES
Dimensions
(PSC)
3"
3 3/4
9 7/16
4
A
B
C
Metal Roof Flashing Adapter
4"
4 3/4
10 7/16
4
This flashing cone fits onto a 6" EXCEL Metal Roof Flashing (6EMFA or 6EMFB, p. 13) to convert it for
use with EXCELPellet vent or EXCELDirect. Metal Roof Flashing and storm collar ordered separately.
(MFA, MFB)
INCHES
Dimensions
Code
A
B
3MFA
4
9 1/2
3MFB
4
11 1/8
4MFA
5
8
4MFB
5
9 1/2
EXCELPellet Offset Tables
Use this table if you are not
installing an adjustable length
between the elbows
LENGTH BETWEEN OFFSETS
3 INCH Ø
NO LENGTH
6" Length
12" Length
24" Length
36" Length
48" Length
48" + 6" Length
48" + 12" Length
48" + 24" Length
48" + 36" Length
48" + 48" Length
48" + 48" + 12" Length
48" + 48" + 24" Length
4 INCH Ø
NO LENGTH
6" Length
12" Length
24" Length
36" Length
48" Length
48" + 6" Length
48" + 12" Length
48" + 24" Length
48" + 36" Length
48" + 48" Length
48" + 48" + 12" Length
48" + 48" + 24" Length
Use this table if you are installing a 16" adjustable length
between the elbow
45° Elbows
RISE
OFFSET
7
9 3/4
14
23 1/4
31
39 1/2
42 1/2
46 3/4
55 3/4
63 3/4
72
79 1/4
88 1/2
2 3/4
5 3/4
10
19 1/4
27
35 1/2
38 1/2
42 3/4
51 3/4
59 1/2
68
75 1/4
84 1/2
7 1/4
10
14 1/4
23 1/2
31 1/4
39 3/4
42 3/4
47
56 1/4
64
72 1/2
79 1/2
88 3/4
3
6
10 1/4
19 1/4
27
35 1/2
38 1/2
42 3/4
52
59 3/4
68 1/4
75 1/4
84 1/2
All measurements are in inches
LENGTH BETWEEN OFFSETS
3 INCH Ø
6" Length*
12" Length
12" + 6" Length*
24" Length
36" Length
48" Length
48" + 6" Length
48" + 12" Length
48" + 24" Length
48" + 36" Length
48" + 48" Length
48" + 48" + 12" Length
48" + 48" + 24" Length
4 INCH Ø
6" Length*
12" Length
12" + 6" Length*
24" Length
36" Length
48" Length
48" + 6" Length
48" + 12" Length
48" + 24" Length
48" + 36" Length
48" + 48" Length
48" + 48" + 12" Length
48" + 48" + 24" Length
45° Elbows
RISE
OFFSET
13 1/2 - 21 1/2
15 1/2 - 23 1/2
18 1/2 - 26 1/4
24 3/4 - 32 1/2
32 1/2 - 40 1/2
41 - 48 3/4
43 3/4 - 51 3/4
48 - 56
57 1/4 - 65 1/4
65 - 73
41 - 48 3/4
80 3/4 - 88 3/4
90 - 97 3/4
9 1/2 - 17 1/2
11 1/2 - 19 1/2
14 1/4 - 22 1/4
20 1/2 - 28 1/2
28 1/2 - 36 1/4
37 - 44 3/4
39 3/4 - 47 3/4
44 - 52
53 1/4 - 61 1/4
61 - 69
69 1/2 - 77 1/2
76 3/4 - 84 1/2
85 3/4 - 93 3/4
13 3/4 - 21 3/4
15 3/4 - 23 3/4
18 3/4 - 26 3/4
25 - 33
32 3/4 - 40 3/4
41 1/4 - 49 1/4
44 1/4 - 52
48 1/2 - 56 1/4
57 1/2 - 65 1/2
65 1/4 - 73 1/4
73 3/4 - 81 3/4
81 - 89
90 1/4 - 98 1/4
9 1/2 - 17 1/2
11 1/2 - 19 1/2
14 1/2 - 22 1/2
20 3/4 - 28 3/4
28 1/2 - 36 1/2
37 - 45
40 - 48
44 1/4 - 52
53 1/4 - 61 1/4
61 1/4 - 69
69 1/2 - 77 1/2
76 3/4 - 84 3/4
86 - 94
All measurements are in inches
* Use a 6" adjustable length instead of the 16" adjustable length
EXCELDirect
DIRECT VENT FOR GAS & PROPANE APPLIANCES
EXCELDirect®
56 Technical Information | EXCELDirect®
EXCELDirect® Technical Information
Certification
Construction
EXCELDirect is certified by INTERTEK testing services.
Flue: .016" Type 430 Stainless Steel
Casing: .019" Galvalume Steel or .022" Satin Coated
(painted black)
Paint: Forrest “Stove Bright” flat black.
Seam: Interior and exterior seams are laser welded.
®
Applications
EXCELDirect® is a certified venting system designed to be
used only with certified direct vent gas fired appliances.
Clearance to Combustible Materials
As determined by the gas appliance specifications
in its instruction manual.
Sizes
4" interior X 6 5/8" exterior
5" interior X 8" exterior
* charts refer to inner diameter.
EXCELDirect® Design Considerations
Prior to starting your installation, we suggest you take the
following into consideration:
1.There are two possible ways to connect a direct vent
venting system to a gas appliance:
▪▪ The horizontal installation (through the wall);
▪▪ The vertical installation (through the roof). Check
the appliance manufacturer’s installation instructions
to see all possible vent configurations.
2.Review all your options for the appliance location
and also venting configuration. Try to minimize the
alteration and reframing of structural components of
the building (wall studs, water pipes, electrical wiring,
ceiling joists, roof rafters, etc.). It may be easier to
change the location of your appliance than to modify
the building structure.
3.Carefully read the appliance and the venting system
instruction manuals. Good planning will save you time,
work and money.
5.For a horizontal installation, you will have to take into
consideration the distance between the gas appliance
adapter to the wall, as well as the wall thickness
and a vertical rise (if applicable). The horizontal
vent termination on the exterior must be located in
accordance with the Installation Codes and Regulations.
6.For a vertical installation, you must consider
the distance between the gas appliance outlet and
the ceiling, the ceiling thickness, the height of the attic
or second floor and allow sufficient vent height above
roof line.
7.For two-story applications, firestops are required
at each floor. If an offset is needed in the attic,
additional lengths and elbows will be required.
8.Contact your local building authority and/or fire
officials for permits, restrictions and installation
inspections. You may also wish to contact your house
insurance representative.
4.Use only authorized EXCELDirect® listed components
unless compatibility with another brand is specified in
the appliance manufacturer’s instructions. Do not use
damaged parts.
4005717
Typical Installations | EXCELDirect®57
NOTE: The following information is provided to assist you in selecting the chimney
components required for your installation. It is intended to be a guideline only. These
are not the installation instructions.
EXCELDirect®
EXCELDirect® Typical Installations
Vertical
Termination
Flashing
Elbow
Horizontal
Termination
Offset
Support
Insulated Wall
Thimble
Elbow
Storm Collar
Length
Attic Radiation
Shield
Length
Round Support
EXCELDirect®
58 Product Descriptions | EXCELDirect®
EXCELDirect® Product Descriptions
Horizontal Termination Kit
(4HTK)
Lengths
(DL6, DL6B, DL9, DL9B, DL1, DL1B,
DL2, DL2B, DL3, DL3B, DL4, DL4B)
Slip Lengths
(DLS1, DLS1B, DLS2, DLS2B)
This classic up and out kit includes a Horizontal Termination (HT), Insulated Wall Thimble (WT), Trim
Plate (TP), Black 90° Elbow (DE90B), Black 9" Length (DL9B) and Black 2’ Length (DL2B).
EXCELDirect® lengths are available in 48", 36", 24", 12", 9" & 6". All lengths have a stainless steel
interior and either a Galvalume or “Stove Bright” flat black exterior. All EXCELDirect® lengths fit
directly onto DuraVent flue collars without the need for an adapter.
Slip lengths enable an installer to adjust the system to the exact overall length required for any
installation. Slip lengths must be installed above a straight length that is not adjustable and will
not adjust into an elbow.
INCHES
Dimensions
Code
DL6
DL9
DL1
DL2
DL3
DL4
A
5 5/8
8 5/8
11 5/8
23 5/8
35 5/8
47 5/8
B
4 1/4
7 1/4
10 1/4
22 1/4
34 1/4
46 1/4
DLS1
DLS2
Adds 1 7/8" - 9"
Adds 1 7/8" - 21"
Slip Lengths
Telescopic Length
(DLA30, DLA30B)
The Telescopic Length includes two pipe sections that must be used together. The joint between the
pipe sections is cleaner looking than using a slip length. Telescoping from 16 1/2" to 29" in length
makes it Ideal for up and out installations.
INCHES
Telescopic Length
DLA30
Adjustable from 16 1/2" to 29"
Product Descriptions | EXCELDirect®59
(DE45, DE45B, DE90, DE90B)
EXCELDirect® elbows are available in 45° and 90° and also in Black or Galvalume. The stainless
steel inner casings are seam welded to ensure there is no leakage.
INCHES
Dimensions
Code
4DE90
4DE45
5DE90
5DE45
NEW
Slip Elbow
(DE90S, DE90SB)
A
6 3/4
3 5/8
7 5/8
4
B
7
4 3/8
7 7/8
4 5/8
The vertical section of the slip elbow slides over a standard length just like a slip section of pipe.
This eliminates the need for a separate slip piece. The installation can be completed faster and
with fewer joints.
INCHES
Dimensions
4DE90S
5DE90S
Ceiling Support / Firestop
(CS)
A max.
11 1/2
11 1/2
A min.
4 3/4
5
B
6 7/8
7 3/4
The Ceiling Support/Firestop is the most common support. It can be used on any floor level. It is the
perfect choice when a structure hides the venting system. Simply screw the support to the framed
joist with four #8 x 1 1/2" wood screws or use four spiral nails, 2" long. The Ceiling Support/Firestop
acts as a firestop and a support when installed from below. It can also be installed above the joists;
however an additional firestop is required from below in this case.
INCHES
Dimensions
A
B
C
4CS
6 3/4
8 3/4
10 3/4
5CS
8 1/8
10
12
EXCELDirect®
Elbows 45° & 90°
EXCELDirect®
60 Product Descriptions | EXCELDirect®
Round and Square Support /
Radiation Shield
(RDS, SS)
EXCELDirect® supports are suitable for use on flat or sloping ceilings. The amount they project into
the room is determined only by the desired visual effect, but must be more than 1/4 inch. These
supports are designed to act as a combination of support and attic radiation shield. To use either
support as an attic radiation shield, simply close the open area at the top of the support (in the
attic) with a storm collar. The Round & Square Supports can hold up to 50’ of 4"x 6 5/8" venting or
40’ of 5"x 8".
INCHES
Square Support Dimensions
A
B
C
4SS
6 3/4
9 3/4
24
5SS
8 1/8
10 3/4
24
Round Support Dimensions
A
B
C
Insulated Wall Thimble
(WT)
4RDS
6 3/4
9 3/4
15 3/4
5RDS
8 1/8
10 3/4
15 3/4
Telescopes to accommodate wall thickness from 5 3/4" to 10 1/2". It is fully insulated and fits tightly
to prevent heat loss. The 4" X 6 5/8" venting requires an 8 3/4" x 8 3/4" framed opening; the 5" X 8"
venting requires a 10" x 10" framed opening.
INCHES
Dimensions
A
B
C
D
Wall Thimble Extension
(WTE)
4WT
7
8 5/8
12
5 3/4 to 10 1/2
5WT
8 3/8
9 7/8
13
5 3/4 to 10 1/2
UL listed Wall Thimble insulated extensions. They install easily and will allow our standard wall
thimble (WT) to fit walls up to 20 3/4" thick.”
INCHES
Dimensions
A
B
C
4WTE
6 7/8
8 1/2
5WTE
8 1/4
9 3/4
5 3/4 to 15
Product Descriptions | EXCELDirect®61
These Trims are typically used as decorative covers when installing a wall thimble in a gas stove
application. On vertical installations they can serve as firestops when installed from below. They
can also serve as a firestop on horizontal installations that don’t require a wall thimble (i.e. a fully
non-combustible wall). The Trim Ring (TR) is larger and round and the Trim Plate (TP) is smaller and
square. Available in black only.
(TR, TP)
All EXCELDirect trims include a rubberized O-ring to seal the gap between the trim and vent.
Trim plate (TP)
Trim ring (TR)
INCHES
Dimensions
A
B
Adjustable Wall Support
(WS)
4TP
6 7/8
12 1/4
4TR
6 7/8
19
5TP
8 1/4
13
5TR
8 1/4
20
Rated to support up to 13’ (4" x 6 5/8") or 10’ (5" x 8") of venting. The universal support collar is
adjustable for either the 6 5/8" or 8" outside vent casing. It adjusts easily to provide from 1" to 5"
of clearance to the wall.
INCHES
Dimensions
A
B
C
D
Offset Support
(OS)
WS (universal)
6 1/2 or 7 7/8
7 1/2
2
4 1/4
The offset support is primarily used to re-support the chimney above an offset. However it can also
be used to provide additional support when the chimney height exceeds the capacity of the primary
support, or to support horizontal runs. The offset support straps are 24 inches long and the collar is
adjustable to fit the 6 5/8" or 8" outside vent casing.
INCHES
Dimensions
A
B
Horizontal Terminations
(HT, DHT)
OS (universal)
6 1/2 or 7 7/8
24
Both horizontal terminations are tested to high wind conditions and perform well even at winds
equivalent to 40 mph. The Deluxe Termination is arched, while the regular cap is angular. The
length connected to the terminations is a slip section that provides adjustment through the wall. All
Horizontal Terminations have built-in vinyl siding standoffs for siding up to 1 1/2" deep. For deeper
siding, an additional Vinyl Siding Standoff (VSS) is required.
INCHES
Dimensions
Regular
Deluxe
Ø
A
B
C
D
4"
6 3/4
5 1/4
7 5/8
14
5"
8 1/8
5 1/4
7 5/8
14
EXCELDirect®
Trim Ring, Trim Plate
EXCELDirect®
62 Product Descriptions | EXCELDirect®
Vinyl Siding Standoff
(VSS)
Required when siding is more than 1 1/2" deep. Prevents damage to temperature sensitive siding
materials such as vinyl, shakes or shingles. For use with horizontal terminations only.
INCHES
Dimensions
Ø
A
B
C
Vertical Termination
VSS (universal)
5
14
1 1/2
The SVT cap is made of stainless steel and is welded during assembly to ensure lasting performance.
It is certified to high wind applications where the vent terminates vertically. It cannot be installed
horizontally.
(SVT)
INCHES
Dimensions
Ø
A
B
C
D
4"
6 5/8
10 1/2
9 1/2
12 1/4
5"
8
10 1/2
9 1/2
12 1/4
REDESIGNED
SVT
Insert Vertical Termination
(IVT)
Used when installing a direct vent system in a masonry chimney using two aluminum flex liners. The
IVT has a 3" air inlet and a 4" exhaust. An adapter for 3" exhaust is included. Requires a flashing
(MF, MFR, MFC or IVTP). Certified for high wind. The optional Wind / Rain Shield (SVTS) can improve
performance in extreme wind conditions. Stainless steel construction.
INCHES
Dimensions
A
B
C
NEW
Universal
Flashing
for IVT
Made of galvalume, this flashing can be cut,
bent, or secured with silicone to the top of a
masonry chimney.
(MFR)
8 1/8
10 1/2
12 1/4
NEW
Clay Tile
Flashing
for IVT
(MFC)
20"
20"
Made of galvalume and designed to fit onto a
clay tile flue. Optional Hose Clamp Bracket (HC)
can be used or it can be secured in the method
of your choice.
13 1/2"
13 1/2"
Product Descriptions | EXCELDirect®63
Made of stainless steel for added rigidity and
corrosion resistance.
(MF)
16"
NEW
Prefab
Chimney
Top Adapter
For co-linear direct vent installations in a
prefab chimney. Will fit any round prefab
chimney up to 11 1/2" OD. Use with the IVT
termination only.
(IVTP)
13"
8"
EXCELDirect®
Masonry
Flashing for IVT
16"
Ø
Fits chimneys 8"- 11" OD
(CT3, CT4)
This stainless steel cap is designed for a direct vent insert installation in a masonry chimney that
uses two aluminum flex liners. Requires a flashing (CTF, or CTFC). Certified for high wind. The
optional Wind / Rain Shield (CTS) can improve performance in extreme wind conditions.
INCHES
Dimensions
A
B
C
D
E
F
NEW
Universal Flashing for
Traditional Cap
CT3
6 1/2
2
2 7/8
2 7/8
16 1/2
12
Made of galvalume, this flat flashing base is easy to cut, bend, or simply silicone to the top of a
masonry chimney.
INCHES
(CTF)
Dimensions
A
B
C
NEW
Clay Tile Flashing
for Traditional Cap
CT4
6 1/2
2
2 7/8
3 3/4
16 1/2
12
11 3/4
7 1/4
20
Made of galvalume and designed to fit onto a clay tile flue. Optional Hose Clamp Bracket (HC) can
be used or it can be secured in the method of your choice.
INCHES
Dimensions
(CTFC)
A
B
C
D
11 3/4
7 1/4
13 3/4
1 1/2
REDESIGNED
Traditional Co-Linear
Chimney Cap
EXCELDirect®
64 Product Descriptions | EXCELDirect®
NEW
Hose Clamp Bracket
Heavy duty hose clamp and two mounting brackets for Clay Tile Flashings (MFC and CTFC).
(HC)
68" long
NEW
Wind / Rain Shield
(SVTS, CTS)
SVTS
Snorkel Termination
(ST14, ST36)
Optional Wind and Rain Shields prevent issues caused by strong wind or driving rain. The SVTS
shield will fit the SVT or IVT cap, the CTS is for the Traditional Style caps.
Termination
Wind / Rain Shield
SVT, IVT
CT3, CT4, PCT
SVTS
CTS
CTS
There are two Snorkel Terminations designed for use when a vertical rise is desired on the exterior
of the home, or if the installation is below grade.
INCHES
Dimensions
Ø
A
B
C
D
E
ST14
4"
6 5/8
7 to 10 3/4
6 1/2
26 3/8
12 3/4
ST36
5"
8
7 to 10 3/4
6 1/2
26 3/8
12
4"
6 5/8
7 to 10 3/4
6 1/2
48 3/8
12 3/4
5"
8
7 to 10 3/4
6 1/2
48 3/8
12
Adjustable Flashing
Our Flashings are made of galvalume steel and there are versions to fit any pitch.
(F, FA, FB)
For 5" x 8" EXCELDirect, a 6" EXCEL chimney flashing is used. Similarly, for installations through
metal roofs, a 6" EXCEL Metal Roof Flashing should be used in combination with a Metal Roof
Flashing Adapter (4MFA, 4MFB).
4F Flat roof
4FA 1/12 – 7/12 pitch roof
4FB 8/12 – 12/12 pitch roof
INCHES
Dimensions
Flashings include a storm collar
A
B
C
D
4F
7
20
20
8
4FA
7
20
20
3 3/4
4FB
7
22
26
3 3/4
For 5", use EXCEL flashings 6EF, 6EFA, 6EFB
Product Descriptions | EXCELDirect®65
(MFA, MFB)
This flashing cone fits onto a 6" EXCEL Metal Roof Flashing (6EMFA or 6EMFB, page 13) to convert
it for use with EXCELPellet vent or EXCELDirect. Metal Roof Flashing and storm collar ordered
separately.
INCHES
Dimensions
Code
A
B
Storm Collars
3MFA
4
9 1/2
3MFB
4
11 1/8
4MFA
5
8
4MFB
5
9 1/2
The storm collars fit both 4" x 6 5/8" and 5" x 8" EXCELDirect®. The regular Storm Collar (SC) is
required to be used in combination with the Round Support or Attic Radiation Shield to form an attic
insulation shield assembly when these components are installed into an insulated space. For square
support installations, use the Square Support Attic Collar (SQSC) in an attic instead.
(SC, SQSC)
INCHES
Dimensions
(SC)
(SQSC)
Attic Radiation Shield / Firestop
(AS)
A
B
C
SC
6 1/2 or 7 7/8
9 1/4 or 10 5/8
2
SQSC
6 1/2 or 7 7/8
14 1/4 or 17
6 7/16
The Attic Radiation Shield / Firestop protects combustible framing in the floor or ceiling adjacent
to the chimney, and also acts as a firestop spacer. When EXCELDirect® passes through the Attic
Radiation Shield into an insulated space, a storm collar (SC) must also be installed to prevent the
entry of insulation. This option CANNOT be used as a support and is typically used when the venting
system will be enclosed.
INCHES
Dimensions
A
B
C
D
Restrictor Disk
(4RD)
4 5/8"
5 1/4"
4AS
6 7/8
10 3/4
8 5/8
17 1/2 to 30
5AS
8 1/4
12
9 7/8
17 1/2 to 30
Used only in accordance with specific manufacturer’s installation instructions to reduce the flow
of combustion air.
EXCELDirect®
Metal Roof Flashing Adapter
EXCELDirect®
66 Product Descriptions | EXCELDirect®
NEW
Flex Liner Connector
Used to join lengths of 3" or 4" flex together securely and without tearing.
(CFAA3, CFAA4)
Co-Axial to Co-Linear
Appliance Adapter
(CAA)
Use with direct vent gas appliances that require 4" x 6 5/8" venting. This part adapts a co-axial flue
outlet to a flexible co-linear system to be used in an existing masonry chimney. Flexible liners are
not provided.
INCHES
Dimensions
Ø
A
B
C
D
E
Co-Linear Termination Adapter
(CTA and CTA4)
4"
6 5/8
10 1/2
7 1/2
2
2 7/8
The Co-Linear Termination Adapter is for direct vent systems that are installed in existing masonry
chimneys and use two co-linear liners. It is made out of stainless steel and is available with either
3" or 4" exhaust.
INCHES
Dimensions
CTA
10 3/8
18
2 7/8
2 7/8
6 1/2
A
B
C
D
E
Type A Chimney Adapter
(CA6, CA7, CA8)
CTA4
10 3/8
18
2 7/8
3 3/4
7 1/2
Provides a positive sealed connection between EXCELDirect® and type A chimneys. The Chimney
Adapter includes a universal connector to tie into the existing chimney and an adapter to connect
to an EXCELDirect® Vertical Cap. A 4 inch flexible liner must be run throughout the existing chimney
and is not included with the Chimney Adapter. Chimney cap ordered separately.
INCHES
Dimensions
Ø
A
B
C
4CA6
4"
6
4
8 1/8
4CA7
4"
7
4
9 1/8
4CA8
4"
8
4
10 1/8
USA only, not available in Canada
Product Descriptions | EXCELDirect®67
(MA)
Easily connect a masonry chimney of any size to a freestanding gas stove with the Masonry Adapter.
It is to be installed in combination with the MTA (Masonry Termination Adapter); 4" diameter flex
and a termination are required.
INCHES
Dimensions
Ø
A
B
C
D
4"
6 5/8
9 1/2
7 7/8
3 3/4
EXCELDirect®
Masonry Adapter
USA only, not available in Canada
Masonry Termination Adapter
(MTA)
Adapts a 4" flexible liner to a direct vent system, typically used with the MA (Masonry Adapter). The
MTA does not include flex and allows for your choice of vertical termination.
INCHES
Dimensions
A
B
C
MTA
6 5/8
18
4
USA only, not available in Canada
(PCT)
This stainless steel cap is designed for direct vent installations in a masonry chimney that uses
a single 4" aluminum flex liner for exhaust and the masonry chimney for fresh air. Requires a
flashing (CTF, or CTFC). Certified for high wind. The optional Wind / Rain Shield (CTS) can improve
performance in extreme wind conditions.
INCHES
Dimensions
A
B
C
D
E
6 1/2
2 3/4
3 3/4
16 1/2
12
REDESIGNED
Traditional Masonry Adapter Cap
EXCELDirect®
68 Offset Tables | EXCELDirect®
EXCELDirect® Offset Tables
Vent Offset Specifications
LENGTH BETWEEN OFFSETS
45° Elbows
90° Elbows
RISE
OFFSET
RISE
OFFSET
10 1/2
13 5/8
17 7/8
26 3/8
43 3/8
4 3/8
7 1/2
11 3/4
20 1/4
37 1/4
10 3/4
10 3/4
10 3/4
10 3/4
10 3/4
10 3/4
15 1/4
21 1/4
33 1/4
57 1/4
11 3/4
14 7/8
19 1/8
27 5/8
44 5/8
4 7/8
8
12 1/4
20 3/4
37 3/4
12"
12"
12"
12"
12"
12"
16 1/2
22 1/2
34 1/2
58 1/2
4 INCH Ø
NO LENGTH
6" Length
12" Length
24" Length
48" Length
5 INCH Ø
NO LENGTH
6" Length
12" Length
24" Length
48" Length
OFFSET
RISE
Open Fireplace Chimney Design Considerations 69
Open Fireplace Chimney Design Considerations
Chimney Sizing and Flue Height
The following information is provided to assist you in
determining the correct chimney size and overall height
required to provide trouble free operation. It is intended
as a guideline only. There are many other factors, which
determine the effective draft of a specific installation.
Sizing Fireplace Chimneys
The chimney-sizing chart on this page determines the
correct chimney size for an open fireplace. For factory-built
fireplaces and woodbuming stoves, use the size specified
by the appliance manufacturer. In most cases, this is the
diameter of the flue collar.
If you need help with a more complicated shape such
as a multisided fireplace or an open fire pit please
feel free to contact us by phone, fax or e-mail. Our
engineering department will be pleased to assist you with
sizing, material specifications, and any other technical
information you require.
TOTAL
CHIMNEY
HEIGHT
HEIGHT, H
WIDTH, W
Example: A fireplace with a 24 inch wide by 18 inch high opening requires a 8 inch
diameter chimney for 15’ of chimney height.
70 Chimney Height Design Considerations
Chimney Height Design Considerations
Recommended Flue Height
Once the correct chimney size has been determined, there are two factors which can be compensated for when calculating
the optimum height of the system-elevation and chimney layout. The higher the elevation, the greater the chimney height
required to provide the same draft as an installation at sea level. The more complex the chimney layout is (the more tees,
elbows, etc. in the system), the greater the chimney height required to provide the same draft as a straight up system.
The minimum overall height of any chimney system is 12 feet for a vertical chimney with no offsets at sea level.
You must increase the vertical height of the system to compensate for horizontal runs, tees, and elbows. To compensate for:
One Tee
Add 3 feet. to the minimum height.
One 45° Elbow
Add I feet. to the minimum height.
One 90° Elbow
Add 2 feet. to the minimum height.
Each foot of horizontal run
Add 2 feet. to the minimum height.
Each 1000 feet. above sea level
Add 4% to the minimum height.
Example 1: House Built at Sea Level
Example 2: Identical House Built at 8,000 feet
A wood burning stove is installed on the main floor of a
single story house at sea level. The chimney is installed
with a 90° elbow through the wall into a tee, then straight
up through the roof. To determine the minimum overall
height add:
To determine the minimum overall height, add 32%
(4% per 1000 feet) to the height calculated in the above
example:
The minimum overall height =
1 1/2 feet of horizontal run =
One “Tee” =
One 90’ Elbow =
Additional Height =
20 feet + 32% = 26.4 feet
If the house were built at an altitude of 5000 feet, the
overall height would be:
12 feet
3 feet
3 feet
2 feet
8 feet
20 feet + 20% (4% per 1000 feet.) = 24 feet
The minimum overall chimney height required is 12 ft. + 8 ft. = 20 ft.
Minimum Recommended Flue Height
from the flue connection on the appliance (feet)
Number of elbows
Elevation Above
Sea Level (feet)
0
2 X 15°
2 X 30°
2 X 45°
4 X 15°
4 X 30°
4 X 45°
1
2
0-1000
12
13
15
16
14
18
20
18
20
1000-2000
12 1/2
13 1/2
15 1/2
16 1/2
14 1/2
19
20 1/2
19
21
2000-3000
13
14
16
17
15
19 1/2
21 1/2
19 1/2
21 1/2
3000-4000
13 1/2
14 1/2
17
18
15 1/2
20
22 1/2
20
22 1/2
4000-5000
14
15
17 1/2
18 1/2
16
21
23
21
23
5000-6000
14 1/2
15 1/2
18
19
17
21 1/2
24
21 1/2
24
6000-7000
15
16
18 1/2
20
17 1/2
22 1/2
25
22 1/2
25
7000-8000
15 1/2
16 1/2
19
20 1/2
18
23
25 1/2
23
25 1/2
8000-9000
16
17
20
21
18 1/2
24
26 1/2
24
26 1/2
9000-10000
16 1/2
17 1/2
20 1/2
22
19
24 1/2
27
24 1/2
27
No more than two offsets (four elbows) allowed
1.
2.
This column shows the height required for a rear vented stove run 18" horizontally into a tee
This column shows the height required for a top vented stove with a 90° degree elbow and an 18" horizontal run into a tee
The table above can be used to determine the minimum height required for many common installations
Index71
Index
EXCEL
EXCELPrime
Adjustable Stud Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Anchor Plate Dampers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Anchor Plate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Attic Radiation Shield for Cathedral Ceiling. . . . . . . . . . . . 15
Attic Radiation Shields. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Chimney Top Damper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Elbows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Extended Wall Supports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Flashings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Flue Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Hardware Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Insulated Adjustable Lengths . . . . . . . . . . . . . . . . . . . . . . . . . 8
Insulated Angled Wall Radiation Shields . . . . . . . . . . . . . . 11
Insulated Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Insulated Tees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Locking Band . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Offset Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Pitched Trim Rings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Radiation Shield for Cathedral Ceiling. . . . . . . . . . . . . . . . . 14
Radiation Shield Tubes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Radiation Shield. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Rain Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Roof Brace Stiffener. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Roof Brace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Roof Radiation Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Roof Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Round & Square Supports. . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Snow-Wedge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Stainless Trim for EWRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Storm Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Support Extensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Universal Vinyl Siding Trim . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Wall Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Wall Radiation Shields (Regular & Insulated) . . . . . . . . . . 11
Wall supports - Wall Bands. . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ULTRABlack
Adjustable Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Conical Trim Ring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Damper Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Elbows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Increasers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Masonry Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Masonry Thimble Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . .
Oval to Round Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reducers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Slip Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stove Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trim Collars. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
21
21
19
20
19
21
21
20
20
19
20
19
21
12" Slip Flue Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adjustable Elbow 90° . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adjustable Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clean Out Elbow 90°. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Elbow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heat Shield Spacer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heat Shield. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Increaser. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Masonry Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Masonry Plug. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Oval to Round Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reducer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Slip Elbow 90°. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Slip Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tee Cap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tee. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29
28
27
28
28
30
30
29
27
30
30
29
29
28
27
27
27
EXCELiner
Adjustable Flex Adapter Elbow. . . . . . . . . . . . . . . . . . . . . . .
Adjustable Snout Tees. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Base Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Elbows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flex Liner Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Increasers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Insulated Wall Thimbles. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ITH Extension. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Offset Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rain Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reducers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Slip Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Split Base Tees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tee Cap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Top Supports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34
33
36
34
35
35
35
35
33
36
36
35
33
33
34
36
72Index
Model RIS
Adjustable Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Anchor Plate Damper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Anchor Plate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chimney Top Damper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Elbows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Insulated Tees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Locking Band . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Offset Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Radiation Shield. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rain Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Roof Brace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Roof Flashings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Roof Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Roof Top Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Spark Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wall Band. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wall Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
40
40
40
39
39
39
42
41
40
40
41
41
41
42
40
41
41
EXCELPellet
3" - 4" Tapered Increaser . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adjustable Jet Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adjustable Wall Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ceiling Support / Radiation Shield . . . . . . . . . . . . . . . . . . . .
Chimney Adapter Cap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clay Tile Flashing for Traditional Cap . . . . . . . . . . . . . . . . .
Clean-Out Elbow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clean-Out Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clean-Out Tee. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Economy Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Elbows. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Female Flex Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flashings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flex Adapter Tee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Harman Stove Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Harman Style Gaskets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Horizontal Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hose Clamp Bracket. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Insulated Wall Thimble. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Masonry Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Metal Roof Flashing Adapter. . . . . . . . . . . . . . . . . . . . . . . . .
Pellet / Liner 5" Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Quick Disconnect Stove Adapter . . . . . . . . . . . . . . . . . . . . .
Rain/Wind Shield. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Slip Elbow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Spark Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Square Support / Radiation Shield. . . . . . . . . . . . . . . . . . . .
Storm Collars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stove Adapter Tee. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stove Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tapered Stove Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
48
52
49
49
50
53
47
46
47
52
47
50
53
50
51
51
52
53
48
46
49
54
50
51
52
47
52
49
54
46
51
51
Tee Cap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tees. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Traditional Masonry Adapter Cap . . . . . . . . . . . . . . . . . . . .
Type A Chimney Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type A Chimney Reline Adapter. . . . . . . . . . . . . . . . . . . . . .
Universal Flashing for Traditional Cap. . . . . . . . . . . . . . . . .
Vertical Rain Cap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wall Thimble Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wall Thimble with Integrated Outside Air. . . . . . . . . . . . . .
Wall Thimble with Outside Air Channel. . . . . . . . . . . . . . . .
47
46
53
49
50
53
52
48
48
48
EXCELDirect®
Adjustable Flashing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adjustable Wall Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Attic Radiation Shield / Firestop. . . . . . . . . . . . . . . . . . . . . .
Ceiling Support / Firestop. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clay Tile Flashing for IVT. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clay Tile Flashing for Traditional Cap . . . . . . . . . . . . . . . . .
Co-Axial to Co-Linear Appliance Adapter. . . . . . . . . . . . . .
Co-Linear Termination Adapter. . . . . . . . . . . . . . . . . . . . . . .
Elbows 45° & 90°. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flex Liner Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Horizontal Termination Kit. . . . . . . . . . . . . . . . . . . . . . . . . . .
Horizontal Terminations. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hose Clamp Bracket. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Insert Vertical Termination . . . . . . . . . . . . . . . . . . . . . . . . . .
Insulated Wall Thimble. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Masonry Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Masonry Flashing for IVT. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Masonry Termination Adapter . . . . . . . . . . . . . . . . . . . . . . .
Metal Roof Flashing Adapter. . . . . . . . . . . . . . . . . . . . . . . . .
Offset Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Prefab Chimney Top Adapter . . . . . . . . . . . . . . . . . . . . . . . .
Radiation Shield. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Restrictor Disk. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Round and Square Support. . . . . . . . . . . . . . . . . . . . . . . . . .
Slip Elbow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Slip Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Snorkel Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storm Collars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Telescopic Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Traditional Co-Linear Chimney Cap. . . . . . . . . . . . . . . . . . .
Traditional Masonry Adapter Cap . . . . . . . . . . . . . . . . . . . .
Trim Ring, Trim Plate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type A Chimney Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Universal Flashing for IVT . . . . . . . . . . . . . . . . . . . . . . . . . . .
Universal Flashing for Traditional Cap. . . . . . . . . . . . . . . . .
Vertical Termination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Vinyl Siding Standoff. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wall Thimble Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wind / Rain Shield. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
64
61
65
59
62
63
66
66
59
66
58
61
64
62
60
58
67
63
67
65
61
63
60
65
60
59
58
64
65
58
63
67
61
66
62
63
62
62
60
64
RSF Woodburning Fireplaces, a division of ICC, is one of North
America’s largest manufacturers of clean burning, high efficiency
fireplaces. RSF has been designing leading edge woodburning
products for over twenty years and manufactures the broadest
range of environmentally friendly fireplaces on the market today.
Renaissance Fireplaces is a line of high end award winning fireplaces
which offer an unmatched view of the fire and very low emissions.
VIP | VIC | IS
Industrial Chimney Company Inc.
Visit our website at www.icc-rsf.com
400 J.F. Kennedy St. Jerome, Quebec, Canada, J7Y 4B7
Tel.: (450) 565-6336 | Fax: (450) 565-6519
XL-CAT_2016_05
ICC Chimney engineers a wide range of
commercial/industrial chimney systems. We
make insulated pressure stacks for applications
ranging from forced draft boilers and industrial
ovens to diesel engine exhaust systems. ICC
can provide complete engineering and design
services from preliminary chimney sizing and
material specifications to detailed 3D AutoCAD
assembly drawings.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising