samsung air conditioning and heat pump systems

samsung air conditioning and heat pump systems
samsung air conditioning and heat pump systems
Catalogue 2010
Smart Thinking,
Simple Living.
Contents
INTRODUCTION
04 | Global business network
RAC SYSTEMS: ROOM AIR CONDITIONERS
10 | Wall mounted units
CAC SYSTEMS: COMMERCIAL AIR CONDITIONERS
26 | Outdoor units
28 | Indoor units
FJM SYSTEMS: FREE JOINT MULTI-SPLIT AIR CONDITIONERS
62 | Outdoor units
68 | Indoor units
78 | Capacity combinations
CONTROLS
87 | Controls range
KEY
91 | Key to icons
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
PROJECT
Kathy Heyndels Glyfada
LOCATION
Greece
TYPE
Shop
4
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Samsung has overtaken Sony as the world's biggest producer of televisions and its strong
product development has resulted in global leadership in the television segment. Samsung
improved its position from third to the second leading player in mobile phones worldwide. The
1.
2.
3.
Coca Cola
IBM
Microsoft
*
*
18.
Honda
20.
Apple
*
*
29.
33.
75.
Sony
Cannon
Panasonic
philosophy of bringing people the latest technology at a fair price has quickly made it a firm
consumer favourite. New concept shops have been successful in translating to a more expert and
demanding audience by showing the benefits of engaging with the brand.
As a global leader, Samsung will continue to create future with the customers.
Global Business Network
6 Global Operation Centers
7 Design Centers
10 Global Headquarters
4 HA R&D Centers
CIS
London
Chicago
Stuttgart
Los Angeles
Europe
US
Mexico
Milano
Shanghai
ME Asia
China
Africa India
SE Asia
SW Asia
Delhi
Korea (Suwon)
Seoul
Korea (Kwangju)
Tokyo
Japan
Osaka
Thailand
Malaysia
Latin America
5
Every day, all of us need to seek new ways to reduce energy consumption at home and at work. To fulfill customer’s greener way of life,
Samsung continues to manufacture eco-friendly products. Unfortunately, many consumers are unaware of green products and feel there
are not enough options. So now, Samsung created PlanetFirst™ which applies to all of Samsung’s eco-friendly products, partnerships
or internal programs.
PlanetFirstTM is the name that easily identifies eco-friendly products from Samsung. These products join customers' desire of living a green
lifestyle with enjoying the latest in technology. PlanetFirstTM, a unique communication, makes Samsung's commitment, mind-set, and
approach to greener living clear and straightforward. As Samsung continues to work, develop, engineer, and design innovative products
to satisfy customers, PlanetFirstTM also means these technologies, designs, and manufacturing processes are greener. Your choice of
PlanetFirstTM products helps preserve nature and reduce energy use.
Samsung is always striving to find new and better ways to reduce our impact on the environment without sacrificing complete satisfaction
in its products. Samsung started by simply reducing, reusing, and recycling; then by challenging employees to seek out and adopt
extraordinary breakthroughs that make Samsung's processes and products healthier, safer, and less carbon dependent. So help the
cause and start your own journey in being green with PlanetFirstTM.
Samsung Electronics makes an effort to develop environment-friendly products that minimize the negative impacts on the environment
in every aspect of its products, from raw material procurement, production, transportation, usage, and final disposal. Concerns for the
environment are at the core of each product development.
Samsung's environment-friendly technologies and recycling programs have received global approval, receiving well-known awards and
recognitions worldwide.
Samsung eco mark
6
Energy mark Korea
Eco Mark Korea
Ecoflower EU
Energy Star Mark
TCO Sweden
Blue Angel Germany
EPEAT US
Eco Mark Korea 2
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Samsung's Four Seasons of Hope supports community-based foundations and charities headed by some of this country's favourite
sports legends. Samsung pledges to raise national awareness and funds for these outstanding charities and to identify how others can
also make a difference in the lives of these children and families.
As technology continually evolves, so will your digital lifestyle. When you upgrade your consumer electronics, you will need to recycle your
old products responsibly. That's why we're proud to reaffirm our commitment and responsibility to recycle using the new
Samsung Recycling DirectSM program launched on October 1st, 2008.
7
‘Eco-friendly’ Samsung
Preserves the nature you live in.
Thinking of you and the environment, Samsung plans for the future. Realizing your hopes for a greener,
healthier life for you and the generations that follow, Samsung’s environmentally friendly technologies work
to make the world a more beautiful place.
Air & Water
Conservation
As a leading innovator of environmentfriendly products and technologies,
Samsung products already drastically
reduce the strains on nature's valuable
resources. Samsung uses R-600, a
natural refrigerant, and cyclopentane
insulation in its refrigerators, which do not
promote global warming or add to the
greenhouse effect. Samsung's waterefficient washing machines also use less
detergent and water without affecting
cleanliness, helping conserve water.
Use Less,
Save More
Samsung products are energy
efficient, receiving Energy Grade A+ in
the EU and ENERGY STAR in the U.S.
Samsung washers with ceramic
heaters use less power, which save
you energy, money and time. This
energy-efficient technology protects
you and nature, giving you a greener
lifestyle.
Samsung Eco-Friendly Air Conditioner
Making continuous efforts to stay eco-friendly, Samsung uses R-410A,
all-environmentally-friendly refrigerant, for its air conditioners and
restrains the use of materials with high global warming potential (GWP).
Most Samsung products have received Energy Grade A+ in the EU
and ENERGY STAR in the U.S. These energy-efficient air
conditioners not only save you money, but help conserve the
environment.
8
Global
Recycling
Samsung Electronics is making significant
efforts to save the environment and
complies with the WEEE (Waste
Electrical and Electronic Equipment)
directive by joining or establishing the
recycling schemes for each country.
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Galeria de
Innovacion
2009
Comfort &
iF Product
Design Award Design
2008
2009
Samsung attended Europe’s largest
air-conditioner exhibition “Climatization”
in Madrid, Spain. Samsung air
conditioner's beautiful design with
innovative features was awarded the
“Galeria de Innovacion” The idea behind
this award is to encourage innovation in
the practical application of know-how
and
technologies
in
industrial
development. Once again, Samsung
proves its unsurpassed standards in
quality.
As one of the world's oldest and
prestigious design competitions, the
iF product design award can look
back on a rich and long tradition. This
seal of fine design quality has stood for
qualitatively outstanding design awards
for over 50 years. Samsung's air
conditioner with design innovations has
won the iF product design award for
the year 2009.
Samsung air conditioner continues to
receive worldwide recognition and
awards, proving high quality functions
and beauty to value and satisfying
customers' requirements.
Organized
by
Fiera
Milano
International, the Comfort & Design
Award plays the role of intermediary
between the Jury and companies
participating in the 36th Mostra
Convegno Expocomfort / Expobagno.
The MCE / EXPOBAGNO 2008 aimed
to reward the best product that
shows a high level of environmental
quality, providing a complete overview
of the sector along the lines of
"Comfort & Living Technology".
And Samsung air conditioner won
the prize conferring a valid and
professional recognition on the best
products in the ceremony .
Received Certifications and Awards
9
FJM AIR CONDITIONERS
FJM 2010 Line-Up
62
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Powerful new line-up
Once again we are introducing our product line-up with Samsung’s innovative technology
equipped to each and every one of them. Take a look at Samsung’s 2010 products made
to satisfy you.
2010 Line-Up
OUTDOOR UNITS
MH040FXEA2C
MH050FXEA2C
MH060FXEA3B
MH070FXEA4B
MH080FXEA4B
4.0kW
2 Unit
5.0kW
2 Unit
6.0kW
3 Unit
7.0kW
4 Unit
8.0kW
4 Unit
INDOOR UNITS
Type
Capacity
2.0/2.3 kW
2.6 kW
3.5 kW
5.2 kW
MB(White)
MB(Black)
Vivace
Crystal
Neo Forte
Slim 1Way cassette
Mini 4Way cassette
(3.0kW)
Slim Duct
MSP Duct
Console
63
FJM AIR CONDITIONERS
01 Outdoor Units
Compact but
powerful outdoor unit
For the residential place relatively large for a single air
conditioning system and the commercial place with
limited space for large outdoor units, Samsung free joint
multi air conditioner is the perfect fit for your needs.
Samsung’s free joint multi outdoor unit will make your life
easier with its compact size and surprise you with its
powerful capacity, which can cover the entire space of
your house or business.
PROJECT
Gyong Plaza
LOCATION
Gyong yos, Hungary
TYPE
Shopping-Mall
64
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Feature
4 in 1 System
The Advantage of Samsung’s FJM is that a single outdoor unit supports up to 4 indoor
units. Use your backyard more wisely with much more space available created by less
number of outdoor units.
High Performance
Wide Operation Range of
Outdoor Temperature
BLDC(Twin Rotary) Compressor
BLDC Compressor is applied on all FJM
outdoor models.
Highly Efficient BLDC Motor
- Creative motor core design
- High density neodymium magnet
- Concentrated type stator
Extremely Low Vibration
- Twin eccentric cams
- 2 balance weights
Highly Stable Moving Parts
- Optimal material matching rollers and
vanes
- Highly robust bearings
- Coated vane
- Coated shaft
65
FJM AIR CONDITIONERS
Feature
TBR Sine Wave Compressor
Felt Structure
New FJM models have applied the twin BLDC
compressor with highly stable moving parts, which
reduces torque variation by 70% compared to the
conventional single BLDC compressor.
New felt has been selected for more quiet
compressor operation. Double layered felt
structures and the felt cover on the top of the
compressor absorb and minimize the noise.
Conventional
New
Sine Wave Controller
All the FJM models have adopted this newly developed Sine Wave Controller.
No ripple in the current wave makes soft acoustic quality and reduces noise.
Current
Wave
Current
Wave
Torque
Ripple
Torque
Ripple
Current
Wave
Current
Wave
Torque
Ripple
Torque
Ripple
Conventional Square Wave Controller
66
New Sine Wave Controller
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Specification
Model
MH040FXEA2C MH050FXEA2C MH060FXEA3B
Max number of connectable indoor units
Performance Horse Power
Capacity
Cooling *1)
Heating *2)
Sound
Power
Sound Pressure (Cooling/Heating) *3)
Running
Cooling
Current
Heating
Nominal Input Cooling
Heating
Circuit Breaker(MCCB/ELB)
Power Supply
Mode
Compressor Type
Piston Displacement
Output
Lubricant
Type
Charging
Refrigerant
Type
Factory Charging
Fan
Type
Output
Airflow Rate
Set Size
Net Weight
Shipping Weight
Net Dimensions(WxHxD)
Shipping Dimensions(WxDxH)
Piping
Liquid(Flare)
Connections Gas(Flare)
Installation
Max. Length
Limitation
Max. Height
Operating
Cooling
Temp. Range Heating
HP
kW
Btu/h
kW
Btu/h
dB(A)
A
A
W
W
A
Ø/V/Hz
cc/Rev
kW
cc
kg
W
m3/min
kg
kg
mm
mm
Ø,mm
Ø,mm
m
m
ºC
ºC
MH070FXEA4B
MH080FXEA4B
2
3
2
4
4
1.8
2.0
1.5
2.5
3.0
5.0
5.9
3.9
7.0
8.0
17,060
20,131
13,307
23,884
27,296
5.7
6.3
4.4
8.6
9.3
19,448
21,496
15,013
29,343
31,732
49/51
50/51
48/49
51/52
52/52
6.1
7.3
5.2
8.7
10.5
6.4
6.4
5.1
9.2
10.1
1,330
1,600
1,140
1,900
2,300
1,400
1,400
1,120
2,000
2,200
13.5
14.5
9.0
16.6
16.6
1/220~240/50 1/220~240/50 1/220~240/50 1/220~240/50 1/220~240/50
Heat Pump
Heat Pump
Heat Pump
Heat Pump
Heat Pump
TWIN BLDC INV. TWIN BLDC INV. TWIN BLDC INV. TWIN BLDC INV. TWIN BLDC INV.
19.52
19.52
19.52
25.18
25.18
5.86
5.86
5.86
7.77
7.77
POE
POE
POE
POE
POE
700
700
700
700
700
R410A
R410A
R410A
R410A
R410A
1.3
2.0
2.2
2.8
2.8
Propeller
Propeller
Propeller
Propeller
Propeller
25
40
130
130
130
25.4
32.9
41
44.8
45.4
41
53
59
65
65
44
57
63
70
70
790X548X285
880X638X310
880X798X310
880X798X310 880X798X310
926X630X382 1,023X695X413 1,023X889X413 1,023X889X413 1,023X889X413
1/4X2
1/4X2
1/4X3
1/4X4
1/4X4
3/8X2
3/8X1+1/2X1
3/8X2+1/2X1
3/8X2+1/2X2
3/8X2+1/2X2
30
30
45
70
70
15
15
15
15
15
-5~43
-5~43
-5~43
-5~43
-5~43
-15~24
-15~24
-15~24
-15~24
-15~24
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
67
FJM AIR CONDITIONERS
02 Indoor Units
Variety of
indoor units
There are various types of indoor units for
Samsung’s free joint multi air conditioning system.
With the outdoor unit that supports up to 4 indoor
units, you can choose from wall-mounted,
cassette, duct and console type indoor units.
Mix and match indoor units to satisfy your air
conditioning needs.
PROJECT
Kioupia
LOCATION
Athens, Greece
TYPE
Restaurant
68
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
MB
Auto Roof Shutter (Dust Free)
This unique air conditioner automatically seals off to prevent dirt
infiltration when not in operation.
(Micro Plasma Ionizer)
The world's first technology that generates active hydrogen atoms
together with oxygen ions to improve your Indoor Air Quality.
It protects you from harmful particles and viruses existing in the air.
DNA Filter
It is a new technology that screens selectively for only toxic agents.
This enables a smarter and effective air management compared to
other filters.
Good’sleep II
Innovative technology developed to control the air temperature during
your sleep maintains the optimum skin temperature to let you enjoy a
comfortable sleep as well as a refreshed wake up.
Specification
Model
Performance
Cooling *1)
kW
Btu/h
Heating *2)
kW
Btu/h
Sound
Sound Pressure (High/Low) *3)
dB(A)
Type
Power
Fan
Airflow Rate(Cool/Heat) m3/min
Running Current Cooling/Heating
A
Cooling/Heating
Power Input
W
Power Supply
Ø/V/Hz
Mode
Piping
Connecting Pipe Liquid(Flare)
Ø,mm
Gas(Flare)
Ø,mm
Drain
Ø,mm
kg
Net Weight
Set Size
kg
Shipping Weight
mm
Net Dimensions (WxHxD)
mm
Shipping Dimensions (WxHxD)
MH026FBEA (White)
MH026FBES (Black)
MH035FBEA (White)
MH035FBES (Black)
2.6
8,871
2.9
9,895
31/20
Cross Flow Fan
8.14/8.23
0.18/0.18
30/30
1/220~240/50
Heat Pump
6.35
9.52
ID 18
10.2
11.5
900X304X185
963X349X247
3.5
11,942
3.8
12,966
35/21
Cross Flow Fan
9.16/9.46
0.19/0.19
35/35
1/220~240/50
Heat Pump
6.35
9.52
ID 18
10.2
11.5
900X304X185
963X349X247
MH052FBEA (White)
5.2
17,742
5.6
19,107
40/30
Cross Flow Fan
14.98/14.49
0.3/0.3
50/50
1/220~240/50
Heat Pump
6.35
12.70
ID 18
13.0
16.0
1,100X307X225
1,157X381X292
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
69
FJM AIR CONDITIONERS
Vivace
(Micro Plasma Ionizer)
The world's first technology that generates active hydrogen atoms
together with oxygen ions to improve your Indoor Air Quality.
It protects you from harmful particles and viruses existing in the air.
Good’sleep II
Innovative technology developed to control the air temperature during
your sleep maintains the optimum skin temperature to let you enjoy a
comfortable sleep as well as a refreshed wake up.
Mirror Design
Add chic and graceful image
Slim Solution
Compact size and light weight
Specification
Model
Performance
Cooling *1)
kW
Btu/h
Heating *2)
kW
Btu/h
Sound
Sound Pressure (High/Low) *3)
dB(A)
Type
Power
Fan
Airflow Rate(Cool/Heat) m3/min
Running Current Cooling/Heating
A
Cooling/Heating
Power Input
W
Power Supply
Ø/V/Hz
Mode
Piping
Connecting Pipe Liquid(Flare)
Ø,mm
Gas(Flare)
Ø,mm
Drain
Ø,mm
kg
Net Weight
Set Size
kg
Shipping Weight
mm
Net Dimensions (WxHxD)
mm
Shipping Dimensions (WxHxD)
MH020FVEA
MH026FVEA
MH035FVEA
MH052FVEA
2
6,824
2.2
7,506
31/21
Cross Flow Fan
7.5/8.1
0.18/0.18
30/30
1/220~240/50
Heat Pump
6.35
9.52
ID 18
8.5
11.5
825X285X189
900X349X252
2.6
8,871
2.9
9,895
31/21
Cross Flow Fan
8.5/8.3
0.18/0.18
30/30
1/220~240/50
Heat Pump
6.35
9.52
ID 18
8.5
11.5
825X285X189
900X349X252
3.5
11,942
3.8
12,966
35/21
Cross Flow Fan
10/10.4
0.19/0.19
35/35
1/220~240/50
Heat Pump
6.35
9.52
ID 18
8.5
11.5
825X285X189
900X349X252
5.2
17,742
5.6
19,107
40/30
Cross Flow Fan
14.8/14.8
0.3/0.3
50/50
1/220~240/50
Heat Pump
6.35
12.70
ID 18
12.0
15.0
1,065X298X214
1,137X377X299
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
70
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Crystal
(Micro Plasma Ionizer)
The world's first technology that generates active hydrogen atoms
together with oxygen ions to improve your Indoor Air Quality.
It protects you from harmful particles and viruses existing in the air.
Catechin Filter
Catechin, extracted from green tea, is contained in the filter and
deactivates captured bacteria and unpleasant odours.
Good’sleep II
Innovative technology developed to control the air temperature during
your sleep maintains the optimum skin temperature to let you enjoy a
comfortable sleep as well as a refreshed wake up.
Filter Cleaning Indicator
Always know when to clean the filter. The
Filter Clean Indicator automatically alerts
you when the filter needs to be cleaned
with its illuminating blue light, usually after
about 500 hours of use. Now, you can
always keep your air conditioner clean. Lowers energy consumption up to
50% and reduces the vibration to bring peace into your life.
Specification
Model
MH020FAEA
MH026FAEA
MH035FAEA
MH052FAEA
kW
Btu/h
Heating *2)
kW
Btu/h
Sound
Sound Pressure (High/Low) *3)
dB(A)
Type
Power
Fan
Airflow Rate(Cool/Heat) m3/min
Running Current Cooling/Heating
A
Cooling/Heating
Power Input
W
Power Supply
Ø/V/Hz
Mode
Piping
Connecting Pipe Liquid(Flare)
Ø,mm
Gas(Flare)
Ø,mm
Drain
Ø,mm
kg
Net Weight
Set Size
kg
Shipping Weight
mm
Net Dimensions (WxHxD)
mm
Shipping Dimensions (WxHxD)
2
6,824
2.2
7,506
31/21
Cross Flow Fan
7.9/8.2
0.18/0.18
30/30
1/220~240/50
Heat Pump
6.35
9.52
ID 18
9.0
11.0
820X286X190
892X355X263
2.6
8,871
2.9
9,895
31/21
Cross Flow Fan
9.1/9.3
0.18/0.18
30/30
1/220~240/50
Heat Pump
6.35
9.52
ID 18
9.0
11.0
820X286X190
892X355X263
3.5
11,942
3.8
12,966
35/21
Cross Flow Fan
9.8/10.0
0.19/0.19
35/35
1/220~240/50
Heat Pump
6.35
9.52
ID 18
9.0
11.0
820X286X190
892X355X263
5.2
17,742
5.6
19,107
40/30
Cross Flow Fan
14.2/14.6
0.3/0.3
50/50
1/220~240/50
Heat Pump
6.35
12.70
ID 18
13.0
16.0
1,099X315X217
1,137X377X299
Performance
Cooling *1)
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
71
FJM AIR CONDITIONERS
Neo Forte
Good’sleep II
Innovative technology developed to control the air temperature during
your sleep maintains the optimum skin temperature to let you enjoy a
comfortable sleep as well as a refreshed wake up.
Flush Front Panel
Clean-Cut Front Panel + Silver Accent Line
Specification
Model
Performance
Cooling *
1)
kW
Btu/h
Heating *2)
kW
Btu/h
Sound
Sound Pressure (High/Low) *3)
dB(A)
Type
Power
Fan
Airflow Rate(Cool/Heat) m3/min
Running Current Cooling/Heating
A
Cooling/Heating
Power Input
W
Power Supply
Ø/V/Hz
Mode
Piping
Connecting Pipe Liquid(Flare)
Ø,mm
Gas(Flare)
Ø,mm
Drain
Ø,mm
kg
Net Weight
Set Size
kg
Shipping Weight
mm
Net Dimensions (WxHxD)
mm
Shipping Dimensions (WxHxD)
MH020FNEA
MH026FNEA
MH035FNEA
MH052FNEA
2
6,824
2.2
7,506
32/23
Cross Flow Fan
7.73/8
0.18/0.18
30/30
1/220~240/50
Heat Pump
6.35
9.52
ID 18
7.8
9.4
825X285X189
900X349X252
2.6
8,871
2.9
9,895
32/23
Cross Flow Fan
8.31/8.56
0.18/0.18
30/30
1/220~240/50
Heat Pump
6.35
9.52
ID 18
7.8
9.4
825X285X189
900X349X252
3.5
11,942
3.8
12,966
36/23
Cross Flow Fan
9.54/9.93
0.19/0.19
35/35
1/220~240/50
Heat Pump
6.35
9.52
ID 18
7.8
9.4
825X285X189
900X349X252
5.2
17,742
5.6
19,107
40/30
Cross Flow Fan
13.21/14.22
0.3/0.3
50/50
1/220~240/50
Heat Pump
6.35
12.70
ID 18
13.0
16.0
1,099X315X217
1,137X377X299
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
72
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Slim 1Way Cassette
Only 135mm thick
155mm
135mm
Samsung introduces the world's slimmest indoor air conditioner
unit. Only 135mm thick, the slim 1Way Cassette air conditioner can
be installed practically anywhere.
Drain pan is included within panel
NOTE
Ensure that there is sufficient installation space. Allow at least
170mm for the installation.
Min. 170mm
CEILING SOILING
PREVENTION
WIDE BLADE
WIDE
WIDE
HIGH
HIGH LIFT-UP
DRAIN PUMP
QUICK
QUICK CONNECTION
OF DRAIN PIPE
Quiet Operation
25dB
Low
35dB
Samsung's new blade design
drastically reduces noise levels, so
you can relax in peace and quiet.
30dB
High
43dB
Fan speed
Noise level
Specification
Model
Performance
Cooling *
1)
kW
Btu/h
Heating *2)
kW
Btu/h
Sound
Sound Pressure (High/Low) *3)
dB(A)
Type
Power
Fan
Airflow Rate(Cool/Heat) m3/min
Running Current Cooling/Heating
A
Cooling/Heating
Power Input
W
Power Supply
Ø/V/Hz
Mode
Piping
Connecting Pipe Liquid(Flare)
Ø,mm
Gas(Flare)
Ø,mm
Drain
Ø,mm
kg
Set Size
Net Weight
kg
Shipping Weight
mm
Net Dimensions (WxHxD)
mm
Shipping Dimensions (WxHxD)
Accessories Panel
Drain Pump
MH026FSEA
MH035FSEA
2.6
8,871
2.9
9,895
30/25
Turbo Fan
6.2/7.5
0.23
45
1/220~240/50
Heat Pump
6.35
9.52
VP20(OD 25,ID 20)
10.5
13.5
970x135x410
1,164x212x478
PSSMA (Optional)
24/750
3.5
11,942
3.8
12,966
32/27
Turbo Fan
7.6/8.2
0.25
50
1/220~240/50
Heat Pump
6.35
9.52
VP20(OD 25,ID 20)
10.5
13.5
970x135x410
1,164x212x478
PSSMA (Optional)
24/750
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
73
FJM AIR CONDITIONERS
Mini 4Way Cassette
Compact Size
The Mini 4Way cassette air conditioner
can be installed in one standard ceiling
tile (600Wx600H), which can save
installation time.
Fan Speed Adjustment
Fan speed can be adjusted according to
ceiling height by adjusting dip switch of
indoor unit’s PCB.
3~3.5m
High Ceiling
HIGH
HIGH LIFT-UP
DRAIN PUMP
FRESH
FRESH AIR
INTAKE
QUICK
QUICK CONNECTION
OF DRAIN PIPE
High Energy Efficiency
It’s energy efficient. Easy operation coupled with high efficiency
provides you with remarkable performance at extremely low cost
Specification
Model
Performance
Cooling *
1)
kW
Btu/h
Heating *2)
kW
Btu/h
Sound
Sound Pressure (High/Low) *3)
dB(A)
Type
Power
Fan
Airflow Rate(Cool/Heat) m3/min
Running Current Cooling/Heating
A
Cooling/Heating
Power Input
W
Power Supply
Ø/V/Hz
Mode
Piping
Connecting Pipe Liquid(Flare)
Ø,mm
Gas(Flare)
Ø,mm
Drain
Ø,mm
kg
Set Size
Net Weight
kg
Shipping Weight
mm
Net Dimensions (WxHxD)
mm
Shipping Dimensions (WxHxD)
Accessories Panel
Drain Pump
MH030FMEA
MH035FMEA
MH052FMEA
3.0
10,200
3.4
11,600
30/25
Turbo Fan
10.8/11.7
0.37/0.37
85/85
1/220~240/50
Heat Pump
6.35
9.52
VP 25 (OD 32, ID 25)
17.0
20.0
575x260x575
660x310x635
PMSMA (Optional)
Built-in
3.5
11,900
3.8
12,900
34/27
Turbo Fan
10.8/11.7
0.37/0.37
85/85
1/220~240/50
Heat Pump
6.35
9.52
VP 25 (OD 32, ID 25)
17.0
20.0
575x260x575
660x310x635
PMSMA (Optional)
Built-in
5.2
17,700
5.6
19,100
41/33
Turbo Fan
12.1/13.6
0.52/0.52
120/120
1/220~240/50
Heat Pump
6.35
12.70
VP 25 (OD:32, ID 25)
17.0
20.0
575x260x575
660x310x635
PMSMA (Optional)
Built-in
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
74
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Slim Duct
Flexible Installation
The air inlet can be set up on either the bottom or rear of the unit,
so there is more flexibility in installation.
Rear side air inlet
Diffuser
Tex
Suction Duct
BACTERIA
ANTI-BACTERIA
FILTER
EASY FILTER
CLEANING
SMART PRESSURE
CONTROL
WIRED REMOTE
CONTROLLER
Wired
HIGH
HIGH LIFT-UP
DRAIN PUMP
Bottom side air inlet
Tex
Diffuser
Suction Duct
Slim Design
199mm
Only 199mm thick, this slim
design makes installation,
maintenance and repair
easy.
199mm
220mm
225mm
160
180
200
210
220
230
Specification
Model
MH026FEEA
2.6
8,800
2.9
9,800
30/25
Sirocco Fan
8.6/9.0
MH035FEEA
3.5
11,900
3.8
12,900
32/27
Sirocco Fan
9.8/10.3
2/4
2/4
0.4/0.4
80/80
1/220~240/50
Heat Pump
6.35
9.52
VP 25 (OD 32, ID 25)
26.0
31.0
900x199x600
1,133x333x730
MDP-E075SEE
0.4/0.4
80/80
1/220~240/50
Heat Pump
6.35
0.92
VP 25 (OD 32, ID 25)
26.0
31.0
900x199x600
1,133x333x730
MDP-E075SEE
Performance Cooling *1)
kW
Btu/h
Heating *2)
kW
Btu/h
Sound
Sound Pressure (High/Low) *3)
dB(A)
Type
Power
Fan
Airflow Rate(Cool/Heat) m3/min
External Static
mmAq
Pressure(Standard/High)
Running Current Cooling/Heating
A
Cooling/Heating
Power Input
W
Power Supply
Ø/V/Hz
Liquid(Flare)
Mode
Piping
Ø,mm
Connecting Pipe Gas(Flare)
Drain
Ø,mm
Ø,mm
kg
Net Weight
Set Size
kg
Shipping Weight
mm
Net Dimensions (WxHxD)
mm
Shipping Dimensions (WxHxD)
Accessories Drain Pump
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
75
FJM AIR CONDITIONERS
MSP Duct
Smart Pressure Control
E.S.P Control
Air volume
The Smart Pressure Control System
adjusts fan speed according to E.S.P
(External Static Pressure), so the air
conditioner always gives you
consistent cooling and heating
power regardless of the surrounding
environment.
H
M
L
H
M
L
Minimum
Maximum Static pressure (mmAq)
Easy to Maintain
Reduce time and maintenance costs by
keeping parts easily accessible.
BACTERIA
HIGH
ANTI-BACTERIA
FILTER
EASY FILTER
CLEANING
SMART PRESSURE
CONTROL
HIGH LIFT-UP
DRAIN PUMP
Flexible Installation
Samsung's MSP Duct air conditioners offer different solutions for any
shape room allowing for specific airflow requirements.
L-shaped area
Areas far apart
Specification
Model
Performance Cooling *1)
kW
Btu/h
Heating *2)
kW
Btu/h
Sound
Sound Pressure (High/Low) *3)
dB(A)
Type
Power
Fan
Airflow Rate(Cool/Heat) m3/min
External Static
mmAq
Pressure(Standard/High)
Running Current Cooling/Heating
A
Cooling/Heating
Power Input
W
Power Supply
Ø/V/Hz
Liquid(Flare)
Mode
Piping
Ø,mm
Connecting Pipe Gas(Flare)
Drain
Ø,mm
Ø,mm
kg
Net Weight
Set Size
kg
Shipping Weight
mm
Net Dimensions (WxHxD)
mm
Shipping Dimensions (WxHxD)
Accessories Drain Pump
MH052FUEA
5.2
17,742
5.6
19,107
37/33
Sirocco Fan
16.3/15.8
4/6
1.04/1.04
170/170
1/220~240/50
Heat Pump
6.35
12.70
ID 26.5
29.0
34.0
900x260x480
1,146x363x584
MDP-M075SGU3
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
76
Y-shaped area
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Console
Slim Design
199mm
It can't get any slimmer. This newly
introduced console type air conditioner
is only 199mm thick, the slimmest on the
market. Its slim design easily
integrates the unit into your decor.
Black Display
Functional art, the touch screen display
is elegant while it maximizes the
convenience of control.
(Micro Plasma Ionizer)
The world's first technology that generates active hydrogen atoms
together with oxygen ions to improve your Indoor Air Quality.
It protects you from harmful particles and viruses existing in the air.
INTERIOR
DESIGN
INTERIOR
DESIGN
SILENT MODE
BACTERIA
Flexible Pipe
Installation
ANTI-BACTERIA
FILTER
FLEXIBLE PIPE
INSTALLATION
LIGHT
Wireless
LIGHT WEIGHT
UNIT
WIRELESS
REMOTE CONTROL
Silent Operation (23dB)
The silent, yet powerful and efficient
cooling and heating system keeps things
more comfortable. Silent mode is
available in 4 different operating modes:
High / Medium / Low / Silence.
Specification
Model
Performance
Cooling *
1)
kW
Btu/h
Heating *2)
kW
Btu/h
Sound
Sound Pressure (High/Low) *3)
dB(A)
Type
Power
Fan
Airflow Rate(Cool/Heat) m3/min
Running Current Cooling/Heating
A
Cooling/Heating
Power Input
W
Power Supply
Ø/V/Hz
Mode
Piping
Connecting Pipe Liquid(Flare)
Ø,mm
Gas(Flare)
Ø,mm
Drain
Ø,mm
kg
Net Weight
Set Size
kg
Shipping Weight
mm
Net Dimensions (WxHxD)
mm
Shipping Dimensions (WxHxD)
MH026FJEA
MH035FJEA
MH052FJEA
2.6
8,871
2.9
9,895
28/23
Turbo Fan
9.0/10.5
0.25/0.25
30/30
1/220~240/50
Heat Pump
6.35
9.52
ID 18
15.0
19.0
720x620x199
810x710x295
3.5
11,942
3.8
12,966
39/24
Turbo Fan
10.5/11.3
0.29/0.29
35/35
1/220~240/50
Heat Pump
6.35
9.52
ID 18
15.0
19.0
720x620x199
810x710x295
5.2
17,742
5.6
19,107
44/25
Turbo Fan
11.2/12.6
0.35/0.35
50/50
1/220~240/50
Heat Pump
6.35
12.70
ID 18
15.0
19.0
720x620x199
810x710x295
Notes
*1) Nominal cooling capacities are based on - Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*2) Nominal heating capacities are based on - Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB,
Equivalent refrigerant piping: 7.5m, Level differences: 0m
*3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
Specifications are subject to change without prior notice for product improvement.
77
FJM AIR CONDITIONERS
03 Capacity Combination
Capacity
Combination
Different installation settings of outdoor / indoor
units can result in a different capacity
combination for each setting.
PROJECT
Auditorio Municipal da vila de velas
LOCATION
S. Jorge island (Azores), Portugal
TYPE
Auditorium
78
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Combination Table
MH040FXEA2C
Number
of Unit
1 Unit
2 Unit
Cooling
Cooling Capacity(W)
Indoor Unit Combination
A
B
C
D
%
Total
A
B
C
D
Total
2000
2600
3500
2000
2000
2000
2600
2600
2000
2600
3500
2600
3500
-
MAX
51%
67%
90%
103%
118%
141%
133%
156%
2000
2600
3500
4000
4600
5500
5200
6100
2100
2600
3500
1950
1696
1418
1950
1662
1950
2204
2482
1950
2238
-
-
2100
2600
3500
3900
3900
3900
3900
3900
Capacity
Current
Power Consumption
Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. EER
W
W
A
W
Ml
W
W
A
A
1280
1280
1300
1350
1500
1500
1500
1500
2100
2600
3500
3900
3900
3900
3900
3900
2520
3120
4200
4200
4200
4200
4200
4200
400
400
400
420
420
440
440
440
540
750
1160
1160
1140
1160
1160
1140
630
880
1240
1250
1250
1250
1250
1250
2.2
2.2
2.2
2.3
2.3
2.4
2.4
2.4
2.5
3.4
5.3
5.3
5.2
5.3
5.3
5.2
2.9
4.0
5.7
5.7
5.7
5.7
5.7
5.7
3.89
3.47
3.02
3.36
3.42
3.36
3.36
3.42
EG
A
A
B
A
A
A
A
A
Heating
Number
of Unit
1 Unit
2 Unit
Heating Capacity(W)
Indoor Unit Combination
Capacity
Current
Power Consumption
A
B
C
D
%
Total
A
B
C
D
Total
Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP
W
Ml
W
W
A
A
W
W
A
2200
2900
3800
2200
2200
2200
2900
2900
2200
2900
3800
2900
3800
-
-
50%
66%
86%
100%
116%
136%
132%
152%
2200
2900
3800
4400
5100
6000
5800
6700
2400
3100
3800
2200
1898
1613
2200
1904
2200
2502
2787
2200
2496
-
-
2400
3100
3800
4400
4400
4400
4400
4400
1300
1300
1300
1500
1500
1500
1500
1500
2400
3100
3800
4400
4400
4400
4400
4400
2990
3450
4370
4700
4700
4700
4700
4700
280
280
280
300
300
300
300
300
800
900
1160
1160
1160
1160
1160
1120
910
1080
1420
1390
1420
1490
1490
1490
1.5
1.5
1.5
1.6
1.6
1.6
1.6
1.6
3.7
4.1
5.3
5.3
5.3
5.3
5.3
5.1
4.2
4.9
6.5
6.4
6.5
6.8
6.8
6.8
3.00
3.44
3.28
3.79
3.79
3.79
3.79
3.93
EG
D
B
C
A
A
A
A
A
Note
1. Cooling capacity is based on 27°C DB / 19°CWB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°CWB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.
- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:
- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
79
FJM AIR CONDITIONERS
Combination Table
MH050FXEA2C
Number
of Unit
1 Unit
2 Unit
Cooling
Cooling Capacity(W)
Indoor Unit Combination
Capacity
Current
Power Consumption
A
B
C
D
%
Total
A
B
C
D
Total
Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. EER
W
W
A
W
Ml
W
W
A
A
2000
2600
3500
5200
2000
2000
2000
2000
2600
2600
2600
3500
2000
2600
3500
5200
2600
3500
5200
3500
-
-
40%
52%
70%
104%
80%
92%
110%
144%
104%
122%
156%
140%
2000
2600
3500
5200
4000
4600
5500
7200
5200
6100
7800
7000
2400
2600
3500
5000
2000
2000
1818
1389
2500
2131
1667
2500
2000
2600
3182
3611
2500
2869
3333
2500
-
-
2400
2600
3500
5000
4000
4600
5000
5000
5000
5000
5000
5000
1280
1280
1280
1300
1350
1350
1350
1500
1500
1500
1500
1500
2400
2600
3500
5000
4000
4600
5000
5000
5000
5000
5000
5000
2880
3120
4200
5200
4800
5200
5400
5400
5400
5400
5400
5400
400
400
400
400
420
420
420
440
440
440
440
440
730
800
1090
1660
1245
1430
1490
1380
1500
1500
1330
1500
880
960
1310
1740
1490
1720
1780
1800
1780
1780
1800
1780
1.9
1.9
1.9
1.9
2
2
2
2.1
2.1
2.1
2.1
2.1
3.3
3.7
5
7.6
5.7
6.5
6.8
6.3
6.9
6.9
6.1
6.9
4
4.4
6
8
6.8
7.9
8.1
8.2
8.1
8.1
8.2
8.1
3.29
3.25
3.21
3.01
3.21
3.22
3.36
3.62
3.33
3.33
3.76
3.33
EG
A
A
A
B
A
A
A
A
A
A
A
A
Heating
Number
of Unit
1 Unit
2 Unit
Heating Capacity(W)
Indoor Unit Combination
Capacity
Power Consumption
A
B
C
D
%
Total
A
B
C
D
Total
Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP
W
W
A
W
Ml
W
W
A
A
2200
2900
3800
5600
2200
2200
2200
2200
2900
2900
2900
3800
2200
2900
3800
5600
2900
3800
5600
3800
-
-
39%
51%
67%
98%
77%
89%
105%
137%
102%
118%
149%
133%
2200
2900
3800
5600
4400
5100
6000
7800
5800
6700
8500
7600
2500
2900
3800
5400
2200
2200
2090
1608
2850
2467
1945
2850
2200
2900
3610
4092
2850
3233
3755
2850
-
-
2500
2900
3800
5400
4400
5100
5700
5700
5700
5700
5700
5700
1300
1300
1300
1450
1450
1450
1500
1500
1500
1500
1500
1500
2500
2900
3800
5400
4400
5100
5700
5700
5700
5700
5700
5700
2990
3340
4370
5600
4750
5460
6300
6400
6300
6300
6400
6300
320
320
320
340
350
350
350
350
350
350
350
350
Note
1. Cooling capacity is based on 27°C DB / 19°C WB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°C WB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.
- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:
- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
80
Current
880
1030
1300
1810
1220
1410
1520
1440
1550
1480
1400
1470
1010
1290
1620
2060
1390
1610
1950
1830
2060
1940
1830
1890
1.7
1.7
1.7
1.8
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
4
4.7
5.9
8.3
5.6
6.5
7
6.6
7.1
6.8
6.4
6.7
4.6
5.9
7.4
9.4
6.4
7.4
8.9
8.4
9.4
8.9
8.4
8.6
2.84
2.82
2.92
2.98
3.61
3.62
3.75
3.96
3.68
3.85
4.07
3.88
EG
D
D
D
D
A
A
A
A
A
A
A
A
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
MH060FXEA3B
Number
of Unit
1 Unit
2 Unit
3 Unit
Cooling
Cooling Capacity(W)
Indoor Unit Combination
Capacity
Current
Power Consumption
EG
A
B
C
D
%
Total
A
B
C
D
Total
Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. EER
W
W
A
W
Ml
W
W
A
A
2000
-
-
-
34%
2000
2400
-
-
-
2400
1280
2400
2880
400
730
930
2.2
3.3
4.3
3.29
A
2600
-
-
-
44%
2600
2600
-
-
-
2600
1280
2600
3120
400
790
1010
2.2
3.6
4.6
3.29
A
3500
-
-
-
59%
3500
3500
-
-
-
3500
1280
3500
4200
400
1070
1370
2.2
4.9
6.3
3.27
A
5200
-
-
-
88%
5200
5200
-
-
-
5200
1300
5200
5800
400
1620
1900
2.2
7.4
8.7
3.21
A
2000
2000
-
-
68%
4000
2000
2000
-
-
4000
1300
4000
4800
420
1240
1480
2.3
5.7
6.8
3.23
A
2000
2600
-
-
78%
4600
2000
2600
-
-
4600
1300
4600
5520
420
1410
1680
2.3
6.5
7.7
3.26
A
2000
3500
-
-
93%
5500
1909
3341
-
-
5250
1300
5250
6290
430
1550
1820
2.3
7.1
8.3
3.39
A
2000
5200
-
-
122%
7200
1528
3972
-
-
5500
1380
5500
6600
430
1580
1850
2.3
7.2
8.5
3.48
A
2600
2600
-
-
88%
5200
2600
2600
-
-
5200
1300
5200
5800
420
1620
1800
2.3
7.4
8.2
3.21
A
2600
3500
-
-
103%
6100
2259
3041
-
-
5300
1300
5300
6400
430
1550
1840
2.3
7.1
8.4
3.42
A
2600
5200
-
-
132%
7800
1967
3933
-
-
5900
1380
5900
6800
430
1610
1880
2.3
7.4
8.6
3.66
A
3500
3500
-
-
119%
7000
2725
2725
-
-
5450
1300
5450
6560
430
1570
1850
2.3
7.2
8.5
3.47
A
3500
5200
-
-
147%
8700
2374
3526
-
-
5900
1380
5900
6800
440
1620
1880
2.4
7.4
8.6
3.64
A
2000
2000
2000
-
102%
6000
1760
1760
1760
-
5280
1500
5280
6380
430
1550
1840
2.3
7.1
8.4
3.41
A
2000
2000
2600
-
112%
6600
1636
1636
2127
-
5400
1500
5400
6490
430
1560
1850
2.3
7.1
8.5
3.46
A
2000
2000
3500
-
127%
7500
1573
1573
2753
-
5900
1500
5900
6800
440
1610
1880
2.4
7.4
8.6
3.66
A
2000
2600
2600
-
122%
7200
1528
1986
1986
-
5500
1500
5500
6600
430
1580
1850
2.3
7.2
8.5
3.48
A
2000
2600
3500
-
137%
8100
1457
1894
2549
-
5900
1500
5900
6800
440
1610
1880
2.4
7.4
8.6
3.66
A
2000
3500
3500
-
153%
9000
1311
2294
2294
-
5900
1500
5900
6800
440
1610
1880
2.4
7.4
8.6
3.66
A
2600
2600
2600
-
132%
7800
1967
1967
1967
-
5900
1500
5900
6800
440
1600
1880
2.4
7.3
8.6
3.69
A
2600
2600
3500
-
147%
8700
1763
1763
2374
-
5900
1500
5900
6800
440
1600
1880
2.4
7.3
8.6
3.69
A
Heating
Number
of Unit
1 Unit
2 Unit
3 Unit
Heating Capacity(W)
Indoor Unit Combination
Capacity
Power Consumption
Current
Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP
W
Ml
W
W
A
A
W
W
A
EG
A
B
C
D
%
Total
A
B
C
D
Total
2200
-
-
-
35%
2200
2500
-
-
-
2500
1300
2500
2990
350
880
1110
1.9
4
5.1
2.84
D
2900
-
-
-
46%
2900
2900
-
-
-
2900
1300
2900
3340
350
1030
1270
1.9
4.7
5.8
2.82
D
3800
-
-
-
60%
3800
3800
-
-
-
3800
1300
3800
4370
350
1350
1660
1.9
6.2
7.6
2.81
D
5600
-
-
-
89%
5600
5600
-
-
-
5600
1350
5600
6300
350
1820
1920
1.9
8.3
8.8
3.08
D
2200
2200
-
-
70%
4400
2200
2200
-
-
4400
1400
4400
5060
350
1220
1510
1.9
5.6
6.9
3.61
A
2200
2900
-
-
81%
5100
2200
2900
-
-
5100
1400
5100
5870
350
1490
1830
1.9
6.8
8.4
3.42
B
2200
3800
-
-
95%
6000
2053
3547
-
-
5600
1500
5600
6440
350
1640
1860
1.9
7.5
8.5
3.41
B
2200
5600
-
-
124%
7800
1692
4308
-
-
6000
1500
6000
6900
350
1660
1860
1.9
7.6
8.5
3.61
A
2900
2900
-
-
92%
5800
2900
2900
-
-
5800
1400
5800
6300
350
1700
1910
1.9
7.8
8.7
3.41
B
2900
3800
-
-
106%
6700
2510
3290
-
-
5800
1500
5800
6770
350
1700
1900
1.9
7.8
8.7
3.41
B
2900
5600
-
-
135%
8500
2149
4151
-
-
6300
1500
6300
7300
350
1740
1830
1.9
8
8.4
3.62
A
3800
3800
-
-
121%
7600
2950
2950
-
-
5900
1500
5900
6880
350
1730
1860
1.9
7.9
8.5
3.41
B
3800
5600
-
-
149%
9400
2547
3753
-
-
6300
1500
6300
7300
350
1740
1830
1.9
8
8.4
3.62
A
2200
2200
2200
-
105%
6600
1933
1933
1933
-
5800
1500
5800
6760
350
1590
1840
1.9
7.3
8.4
3.65
A
2200
2200
2900
-
116%
7300
1778
1778
2344
-
5900
1500
5900
6840
350
1610
1840
1.9
7.4
8.4
3.66
A
2200
2200
3800
-
130%
8200
1690
1690
2920
-
6300
1500
6300
7300
350
1660
1830
1.9
7.6
8.4
3.80
A
2200
2900
2900
-
127%
8000
1650
2175
2175
-
6000
1500
6000
6920
350
1590
1840
1.9
7.3
8.4
3.77
A
2200
2900
3800
-
141%
8900
1557
2053
2690
-
6300
1500
6300
7300
350
1630
1830
1.9
7.5
8.4
3.87
A
2200
3800
3800
-
156%
9800
1414
2443
2443
-
6300
1500
6300
7300
350
1560
1830
1.9
7.1
8.4
4.04
A
2900
2900
2900
-
138%
8700
2100
2100
2100
-
6300
1500
6300
7300
350
1650
1830
1.9
7.6
8.4
3.82
A
2900
2900
3800
-
152%
9600
1903
1903
2494
-
6300
1500
6300
7300
350
1400
1830
1.9
6.4
8.4
4.50
A
Note
1. Cooling capacity is based on 27°C DB / 19°C WB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°C WB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.
- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:
- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
81
FJM AIR CONDITIONERS
Combination Table
MH070FXEA4B
Number
of Unit
1 Unit
2 Unit
3 Unit
4 Unit
Cooling
Cooling Capacity(W)
Indoor Unit Combination
Capacity
EER
EG
4.3
3.08
B
5
3.10
B
5.2
7.2
3.10
B
1.9
7
9.9
3.42
A
1490
1.9
5.7
6.8
3.23
A
1430
1720
1.9
6.5
7.9
3.22
A
430
1710
2050
2
7.8
9.4
3.22
A
8400
580
2180
2520
2.7
10
11.5
3.21
A
5200
6240
420
1660
2000
1.9
7.6
9.2
3.13
B
1820
6100
7320
440
1880
2260
2
8.6
10.3
3.24
A
1900
7000
8400
580
2130
2540
2.7
9.7
11.6
3.29
A
7000
1900
7000
8400
580
2120
2530
2.7
9.7
11.6
3.30
A
-
7000
1900
7000
8900
580
2110
2540
2.7
9.7
11.6
3.32
A
-
-
7000
1900
7000
8900
580
2000
2540
2.7
9.2
11.6
3.50
A
2000
2000
-
6000
1810
6000
7200
440
1800
2280
2
8.2
10.4
3.33
A
2000
2000
2600
-
6600
1870
6600
7920
440
1830
2460
2
8.4
11.3
3.61
A
7500
1781
1781
3118
-
6680
1900
6680
8020
580
1835
2410
2.7
8.4
11
3.64
A
131%
9200
1522
1522
3957
-
7000
1900
7000
8900
580
1850
2460
2.7
8.5
11.3
3.78
A
-
103%
7200
1847
2401
2401
-
6650
1900
6650
7980
580
1830
2410
2.7
8.4
11
3.63
A
3500
-
116%
8100
1664
2163
3119
-
6740
1900
6740
8080
580
1840
2460
2.7
8.4
11.3
3.66
A
2600
5200
-
140%
9800
1429
1857
3714
-
7000
1900
7000
8900
580
1880
2460
2.7
8.6
11.3
3.72
A
2000
3500
3500
-
129%
9000
1516
2652
2652
-
6820
1900
6820
8180
580
1850
2510
2.7
8.5
11.5
3.69
A
2000
3500
5200
-
153% 10700
1308
2290
3120
-
7000
1900
7000
8900
580
1930
2510
2.7
8.8
11.5
3.63
A
2600
2600
2600
-
111%
7800
2240
2240
2240
-
6720
1900
6720
8050
580
1840
2420
2.7
8.4
11.1
3.65
A
2600
2600
3500
-
124%
8700
2029
2029
2732
-
6790
1900
6790
8150
580
1850
2460
2.7
8.5
11.3
3.67
A
2600
2600
5200
-
149% 10400
1750
1750
3121
-
7000
1900
7000
8900
580
1880
2510
2.7
8.6
11.5
3.72
A
2600
3500
3500
-
137%
9600
1896
2552
2552
-
7000
1900
7000
8900
580
1880
2460
2.7
8.6
11.3
3.72
A
3500
3500
3500
-
150% 10500
2330
2330
2330
-
6990
1900
6990
8900
580
1900
2510
2.7
8.7
11.5
3.68
A
2000
2000
2000 2000 114%
8000
1680
1680
1680 1680
6720
1900
6720
8070
580
1850
2460
2.7
8.5
11.3
3.63
A
2000
2000
2000 2600 123%
8600
1577
1577
1577 2050
6780
1900
6780
8140
580
1880
2460
2.7
8.6
11.3
3.61
A
2000
2000
2000 3500 136%
9500
1474
1474
1474 2579
7000
1900
7000
8900
580
1900
2460
2.7
8.7
11.3
3.68
A
2000
2000
2600 2600 131%
9200
1522
1522
1978 1978
7000
1900
7000
8900
580
1880
2460
2.7
8.6
11.3
3.72
A
2000
2000
2600 3500 144% 10100
1386
1386
1802 2426
7000
1900
7000
8900
580
1900
2510
2.7
8.7
11.5
3.68
A
2000
2600
2600 2600 140%
9800
1429
1857
1857 1857
7000
1900
7000
8900
580
1900
2460
2.7
8.7
11.3
3.68
A
2000
2600
2600 3500 153% 10700
1308
1701
1701 2290
7000
1900
7000
8900
580
1930
2550
2.7
8.8
11.7
3.63
A
2600
2600
2600 2600 149% 10400
1750
1750
1750 1750
7000
1900
7000
8900
580
1900
2550
2.7
8.7
11.7
3.68
A
A
B
C
D
%
Total
A
B
C
D
Total
Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.
W
Ml
W
W
A
A
W
W
A
2000
-
-
-
29%
2000
2400
-
-
-
2400
1350
2400
3000
380
780
950
1.7
3.6
2600
-
-
-
37%
2600
2600
-
-
-
2600
1350
2600
3480
390
840
1100
1.8
3.8
3500
-
-
-
50%
3500
3500
-
-
-
3500
1350
3500
4200
400
1130
1580
1.8
5200
-
-
-
74%
5200
5200
-
-
-
5200
1400
5200
6240
420
1520
2160
2000
2000
-
-
57%
4000
2000
2000
-
-
4000
1500
4000
4800
410
1240
2000
2600
-
-
66%
4600
2000
2600
-
-
4600
1690
4600
5520
420
2000
3500
-
-
79%
5500
2000
3500
-
-
5500
1770
5500
6600
2000
5200
-
-
103%
7200
1944
5056
-
-
7000
1900
7000
2600
2600
-
-
74%
5200
2600
2600
-
-
5200
1750
2600
3500
-
-
87%
6100
2600
3500
-
-
6100
2600
5200
-
-
111%
7800
2333
4667
-
-
7000
3500
3500
-
-
100%
7000
3500
3500
-
-
3500
5200
-
-
124%
8700
2816
4184
-
5200
5200
-
-
149% 10400
3500
3500
2000
2000
2000
-
86%
6000
2000
2000
2000
2600
-
94%
6600
2000
2000
3500
-
107%
2000
2000
5200
-
2000
2600
2600
2000
2600
2000
Note
1. Cooling capacity is based on 27°C DB / 19°C WB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°C WB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.
- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:
- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
82
Current
Power Consumption
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
MH070FXEA4B
Number
of Unit
1 Unit
2 Unit
3 Unit
4 Unit
Heating
Heating Capacity(W)
Indoor Unit Combination
Capacity
Power Consumption
Current
A
B
C
D
%
Total
A
B
C
D
Total
Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP
W
W
A
W
Ml
W
W
A
A
2200
-
-
-
26%
2200
2500
-
-
-
2500
1790
2500
3220
580
950
1330
2.7
4.3
6.1
2.63
2600
-
-
-
30%
2600
2900
-
-
-
2900
1820
2900
3680
590
1100
1500
2.7
5
6.9
2.64
E
3800
-
-
-
44%
3800
3800
-
-
-
3800
1930
3800
4600
600
1250
1810
2.7
5.7
8.3
3.04
D
5600
-
-
-
65%
5600
5600
-
-
-
5600
2080
5600
6440
610
1670
2370
2.8
7.6
10.8
3.35
C
2200
2200
-
-
51%
4400
2200
2200
-
-
4400
1980
4400
5060
600
1220
1530
2.7
5.6
7
3.61
A
2200
2900
-
-
59%
5100
2200
2900
-
-
5100
2040
5100
5870
610
1410
1700
2.8
6.5
7.8
3.62
A
2200
3800
-
-
70%
6000
2200
3800
-
-
6000
2110
6000
6900
610
1760
2110
2.8
8.1
9.7
3.41
B
2200
5600
-
-
91%
7800
2200
5600
-
-
7800
2200
7800
9130
620
2150
2700
2.8
9.8
12.4
3.63
A
2900
2900
-
-
67%
5800
2900
2900
-
-
5800
2100
5800
6670
610
1600
1930
2.8
7.3
8.8
3.63
A
2900
3800
-
-
78%
6700
2900
3800
-
-
6700
2170
6700
8040
610
1940
2330
2.8
8.9
10.7
3.45
B
2900
5600
-
-
99%
8500
2729
5271
-
-
8000
2200
8000
9600
620
2210
2650
2.8
10.1
12.1
3.62
A
3800
3800
-
-
88%
7600
3800
3800
-
-
7600
2200
7600
9120
620
2100
2510
2.8
9.6
11.5
3.62
A
3800
5600
-
-
109%
9400
3283
4837
-
-
8120
2200
8120
9740
620
2250
2700
2.8
10.3
12.4
3.61
A
5600
5600
-
-
130% 11200
4250
4250
-
-
8500
2200
8500 10200
620
2250
2740
2.8
10.3
12.5
3.78
A
2200
2200
2200
-
77%
6600
2200
2200
2200
-
6600
2170
6600
7590
610
1830
2530
2.8
8.4
11.6
3.61
A
2200
2200
2900
-
85%
7300
2200
2200
2900
-
7300
2200
7300
8400
620
1880
2590
2.8
8.6
11.9
3.88
A
2200
2200
3800
-
95%
8200
2200
2200
3800
-
8200
2200
8200
9590
620
1930
2660
2.8
8.8
12.2
4.25
A
2200
2200
5600
-
116% 10000
1892
1892
4816
-
8600
2200
8600 10300
620
1960
2700
2.8
9
12.4
4.39
A
2200
2900
2900
-
93%
8000
2200
2900
2900
-
8000
2200
8000
9360
620
1900
2620
2.8
8.7
12
4.21
A
2200
2900
3800
-
103%
8900
2042
2691
3119
-
8260
2200
8260
9670
620
1930
2660
2.8
8.8
12.2
4.28
A
2200
2900
5600
-
124% 10700
1768
2331
4501
-
8600
2200
8600 10300
620
1970
2720
2.8
9
12.4
4.37
A
2200
3800
3800
-
114%
9800
1872
3234
3234
-
8340
2200
8340
9760
620
1950
2690
2.8
8.9
12.3
4.28
A
2200
3800
5600
-
135% 11600
1631
2817
3120
-
8600
2200
8600 10300
620
2000
2760
2.8
9.2
12.6
4.30
A
2900
2900
2900
-
101%
8700
2750
2750
2750
-
8250
2200
8250
9650
620
1930
2660
2.8
8.8
12.2
4.27
A
2900
2900
3800
-
112%
9600
2516
2516
3297
-
8330
2200
8330
9740
620
1950
2690
2.8
8.9
12.3
4.27
A
2900
2900
5600
-
133% 11400
2188
2188
3121
-
8600
2200
8600 10300
620
1980
2730
2.8
9.1
12.5
4.34
A
2900
3800
3800
-
122% 10500
2375
3112
3112
-
8600
2200
8600 10300
620
1980
2730
2.8
9.1
12.5
4.34
A
3800
3800
3800
-
133% 11400
2867
2867
2867
-
8600
2200
8600 10300
620
2000
2760
2.8
9.2
12.6
4.30
A
2200
2200
2200
2200 102%
8800
2063
2063
2063
2063
8250
2200
8250
9660
620
1930
2660
2.8
8.8
12.2
4.27
A
2200
2200
2200
2900 110%
9500
1927
1927
1927
2540
8320
2200
8320
9730
620
1950
2690
2.8
8.9
12.3
4.27
A
2200
2200
2200
3800 121% 10400
1819
1819
1819
3142
8600
2200
8600 10300
620
2000
2760
2.8
9.2
12.6
4.30
A
2200
2200
2900
2900 119% 10200
1855
1855
2445
2445
8600
2200
8600 10300
620
1970
2720
2.8
9
12.4
4.37
A
2200
2200
2900
3800 129% 11100
1705
1705
2247
2944
8600
2200
8600 10300
620
2000
2760
2.8
9.2
12.6
4.30
A
2200
2900
2900
2900 127% 10900
1736
2288
2288
2288
8600
2200
8600 10300
620
2000
2760
2.8
9.2
12.6
4.30
A
2200
2900
2900
3800 137% 11800
1603
2114
2114
2769
8600
2200
8600 10300
620
2000
2760
2.8
9.2
12.6
4.30
A
2900
2900
2900
2900 135% 11600
2150
2150
2150
2150
8600
2200
8600 10300
620
2000
2760
2.8
9.2
12.6
4.30
A
Note
1. Cooling capacity is based on 27°C DB / 19°C WB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°C WB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.
- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:
- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
83
EG
E
FJM AIR CONDITIONERS
Combination Table
MH080FXEA4B
Number
of Unit
1 Unit
2 Unit
3 Unit
4 Unit
Cooling
Cooling Capacity(W)
Indoor Unit Combination
A
B
C
D
%
Total
A
B
C
2000
-
-
-
25%
2000
2400
-
2600
-
-
-
33%
2600
2600
-
-
3500
-
-
-
44%
3500
3500
-
5200
-
-
-
65%
5200
5200
2000
2000
-
-
50%
4000
2000
2600
-
-
58%
2000
3500
-
-
2000
5200
-
2600
2600
2600
2600
Capacity
Current
Power Consumption
Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. EER
W
W
A
W
Ml
W
W
A
A
Total
-
2400
1470
2400
3000
380
780
950
1.7
3.6
4.3
3.08
B
-
2600
1520
2600
3480
390
840
1100
1.8
3.8
5
3.10
B
-
-
3500
1600
3500
4200
400
1130
1580
1.8
5.2
7.2
3.10
B
-
-
-
5200
1750
5200
6240
420
1520
2160
1.9
7
9.9
3.42
A
2000
2000
-
-
4000
1640
4000
4800
410
1240
1490
1.9
5.7
6.8
3.23
A
4600
2000
2600
-
-
4600
1690
4600
5520
420
1430
1720
1.9
6.5
7.9
3.22
A
69%
5500
2000
3500
-
-
5500
1770
5500
6600
430
1710
2050
2
7.8
9.4
3.22
A
-
90%
7200
2000
5200
-
-
7200
1900
7200
8640
580
2240
2690
2.7
10.3
12.3
3.21
A
-
-
65%
5200
2600
2600
-
-
5200
1750
5200
6240
420
1660
2000
1.9
7.6
9.2
3.13
B
3500
-
-
76%
6100
2600
3500
-
-
6100
1820
6100
7320
440
1900
2260
2
8.7
10.3
3.21
A
5200
-
-
98%
7800
2400
4800
-
-
7200
1900
7200
8640
580
2240
2690
2.7
10.3
12.3
3.21
A
3500
3500
-
-
88%
7000
3500
3500
-
-
7000
1900
7000
8400
580
2180
2620
2.7
10
12
3.21
A
3500
5200
-
-
109%
8700
2957
4393
-
-
7350
1900
7350
8820
580
2290
2750
2.7
10.5
12.6
3.21
A
5200
5200
-
-
130% 10400
3825
3825
-
-
7650
1900
7650
9180
580
2380
2860
2.7
10.9
13.1
3.21
A
2000
2000
2000
-
75%
6000
2000
2000
2000
-
6000
1810
6000
7200
440
1850
2310
2
8.5
10.6
3.24
A
2000
2000
2600
-
83%
6600
2000
2000
2600
-
6600
1870
6600
7920
440
2000
2500
2
9.2
11.4
3.30
A
2000
2000
3500
-
94%
7500
2000
2000
3500
-
7500
1900
7500
9000
580
2220
2780
2.7
10.2
12.7
3.38
A
2000
2000
5200
-
115%
9200
1663
1663
4324
-
7650
1900
7650
9180
580
2190
2730
2.7
10
12.5
3.49
A
2000
2600
2600
-
90%
7200
2000
2600
2600
-
7200
1900
7200
8640
580
2150
2680
2.7
9.8
12.3
3.35
A
2000
2600
3500
-
101%
8100
1864
2423
3262
-
7550
1900
7550
9060
580
2150
2690
2.7
9.8
12.3
3.51
A
2000
2600
5200
-
123%
9800
1573
2046
4091
-
7710
1900
7710
9250
580
2190
2730
2.7
10
12.5
3.52
A
2000
3500
3500
-
113%
9000
1698
2971
2971
-
7640
1900
7640
9160
580
2190
2730
2.7
10
12.5
3.49
A
2000
3500
5200
-
134% 10700
1495
2617
3888
-
8000
1900
8000
9300
580
2260
2820
2.7
10.3
12.9
3.54
A
2600
2600
2600
-
98%
7800
2510
2510
2510
-
7530
1900
7530
9030
580
2110
2640
2.7
9.7
12.1
3.57
A
2600
2600
3500
-
109%
8700
2274
2274
3061
-
7610
1900
7610
9130
580
2140
2690
2.7
9.8
12.3
3.56
A
2600
2600
5200
-
130% 10400
1940
1940
3880
-
7760
1900
7760
9300
580
2210
2780
2.7
10.1
12.7
3.51
A
2600
3500
3500
-
120%
9600
2083
2804
2804
-
7690
1900
7690
9230
580
2180
2730
2.7
10
12.5
3.53
A
2600
3500
5200
-
141% 11300
1841
2478
3681
-
8000
1900
8000
9300
580
2260
2870
2.7
10.3
13.1
3.54
A
3500
3500
3500
-
131% 10500
2667
2667
2667
-
8000
1900
8000
9300
580
2260
2820
2.7
10.3
12.9
3.54
A
3500
3500
5200
-
153% 12200
2295
2295
3410
-
8000
1900
8000
9300
580
2300
2910
2.7
10.5
13.3
3.48
A
2000
2000
2000
2000 100%
8000
1888
1888
1888
1888
7550
1900
7550
9050
580
2140
2690
2.7
9.8
12.3
3.53
A
2000
2000
2000
2600 108%
8600
1767
1767
1767
2298
7600
1900
7600
9120
580
2140
2690
2.7
9.8
12.3
3.55
A
2000
2000
2000
3500 119%
9500
1617
1617
1617
2829
7680
1900
7680
9220
580
2180
2730
2.7
10
12.5
3.52
A
2000
2000
2000
5200 140% 11200
1429
1429
1429
3714
8000
1900
8000
9300
580
2300
2870
2.7
10.5
13.1
3.48
A
2000
2000
2600
2600 115%
9200
1663
1663
2162
2162
7650
1900
7650
9180
580
2190
2730
2.7
10
12.5
3.49
A
2000
2000
2600
3500 126% 10100
1531
1531
1990
2679
7730
1900
7730
9280
580
2200
2780
2.7
10.1
12.7
3.51
A
2000
2000
2600
5200 148% 11800
1356
1356
1763
3525
8000
1900
8000
9300
580
2300
2870
2.7
10.5
13.1
3.48
A
2000
2000
3500
3500 138% 11000
1455
1455
2545
2545
8000
1900
8000
9300
580
2280
2870
2.7
10.4
13.1
3.51
A
2000
2600
2600
2600 123%
9800
1573
2046
2046
2046
7710
1900
7710
9250
580
2190
2730
2.7
10
12.5
3.52
A
2000
2600
2600
3500 134% 10700
1495
1944
1944
2617
8000
1900
8000
9300
580
2260
2820
2.7
10.3
12.9
3.54
A
2000
2600
3500
3500 145% 11600
1379
1793
2414
2414
8000
1900
8000
9300
580
2300
2870
2.7
10.5
13.1
3.48
A
2600
2600
2600
2600 130% 10400
1940
1940
1940
1940
7760
1900
7760
9300
580
2220
2780
2.7
10.2
12.7
3.50
A
2600
2600
2600
3500 141% 11300
1841
1841
1841
2478
8000
1900
8000
9300
580
2300
2870
2.7
10.5
13.1
3.48
A
2600
2600
3500
3500 153% 12200
1705
1705
2295
2295
8000
1900
8000
9300
580
2300
2910
2.7
10.5
13.3
3.48
A
Note
1. Cooling capacity is based on 27°C DB / 19°C WB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°C WB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.
- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:
- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
84
EG
D
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
MH080FXEA4B
Number
of Unit
1 Unit
2 Unit
3 Unit
4 Unit
Heating
Heating Capacity(W)
Indoor Unit Combination
Capacity
Power Consumption
Current
A
B
C
D
%
Total
A
B
C
D
Total
Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. COP
W
W
A
W
Ml
W
W
A
A
EG
2200
-
-
-
24%
2200
2500
-
-
-
2500
1790
2500
3220
580
950
1330
2.7
4.3
6.1
2.63
2900
-
-
-
31%
2900
2900
-
-
-
2900
1820
2900
3680
590
1110
1500
2.7
5.1
6.9
2.61
E
3800
-
-
-
41%
3800
3800
-
-
-
3800
1930
3800
4600
600
1250
1810
2.7
5.7
8.3
3.04
D
5600
-
-
-
60%
5600
5600
-
-
-
5600
2080
5600
6440
610
1670
2370
2.8
7.6
10.8
3.35
C
2200
2200
-
-
47%
4400
2200
2200
-
-
4400
1980
4400
5060
600
1220
1530
2.7
5.6
7
3.61
A
2200
2900
-
-
55%
5100
2200
2900
-
-
5100
2040
5100
5870
610
1410
1700
2.8
6.5
7.8
3.62
A
2200
3800
-
-
65%
6000
2200
3800
-
-
6000
2110
6000
6900
610
1760
2110
2.8
8.1
9.7
3.41
B
2200
5600
-
-
84%
7800
2200
5600
-
-
7800
2200
7800
9130
620
2150
2580
2.8
9.8
11.8
3.63
A
2900
2900
-
-
62%
5800
2900
2900
-
-
5800
2100
5800
6670
610
1600
1930
2.8
7.3
8.8
3.63
A
2900
3800
-
-
72%
6700
2900
3800
-
-
6700
2170
6700
7710
610
1940
2330
2.8
8.9
10.7
3.45
B
2900
5600
-
-
91%
8500
2729
5271
-
-
8000
2200
8000
9360
620
2210
2600
2.8
10.1
11.9
3.62
A
3800
3800
-
-
82%
7600
3800
3800
-
-
7600
2200
7600
8740
620
2090
2510
2.8
9.6
11.5
3.64
A
3800
5600
-
-
101%
9400
3283
4837
-
-
8120
2200
8120
9500
620
2250
2650
2.8
10.3
12.1
3.61
A
5600
5600
-
-
120% 11200
4250
4250
-
-
8500
2200
8500
9950
620
2340
2750
2.8
10.7
12.6
3.63
A
2200
2200
2200
-
71%
6600
2200
2200
2200
-
6600
2170
6600
7590
610
1830
2220
2.8
8.4
10.2
3.61
A
2200
2200
2900
-
78%
7300
2200
2200
2900
-
7300
2200
7300
8400
620
1950
2340
2.8
8.9
10.7
3.74
A
2200
2200
3800
-
88%
8200
2200
2200
3800
-
8200
2200
8200
9590
620
2150
2570
2.8
9.8
11.8
3.81
A
2200
2200
5600
-
108% 10000
1896
1896
4827
-
8620
2200
8620 10090
620
2140
2610
2.8
9.8
11.9
4.03
A
2200
2900
2900
-
86%
8000
2200
2900
2900
-
8000
2200
8000
9360
620
2080
2500
2.8
9.5
11.4
3.85
A
2200
2900
3800
-
96%
8900
2109
2779
3642
-
8530
2200
8530
9980
620
2100
2690
2.8
9.6
12.3
4.06
A
2200
2900
5600
-
115% 10700
1785
2353
4543
-
8680
2200
8680 10150
620
2140
2740
2.8
9.8
12.5
4.06
A
2200
3800
3800
-
105%
9800
1931
3335
3335
-
8600
2200
8600 10070
620
2140
2740
2.8
9.8
12.5
4.02
A
2200
3800
5600
-
125% 11600
1764
3047
4490
-
9300
2200
9300 10900
620
2150
2750
2.8
9.8
12.6
4.33
A
2900
2900
2900
-
94%
8700
2840
2840
2840
-
8520
2200
8520
9960
620
2090
2680
2.8
9.6
12.3
4.08
A
2900
2900
3800
-
103%
9600
2595
2595
3400
-
8590
2200
8590 10050
620
2100
2690
2.8
9.6
12.3
4.09
A
2900
2900
5600
-
123% 11400
2226
2226
4298
-
8750
2200
8750 10900
620
2140
2740
2.8
9.8
12.5
4.09
A
2900
3800
3800
-
113% 10500
2392
3134
3134
-
8660
2200
8660 10130
620
2140
2740
2.8
9.8
12.5
4.05
A
2900
3800
5600
-
132% 12300
2193
2873
4234
-
9300
2200
9300 10900
620
2150
2750
2.8
9.8
12.6
4.33
A
3800
3800
3800
-
123% 11400
2910
2910
2910
-
8730
2200
8730 10220
620
2150
2750
2.8
9.8
12.6
4.06
A
3800
3800
5600
-
142% 13200
2677
2677
3945
-
9300
2200
9300 10900
620
2180
2790
2.8
10
12.8
4.27
A
2200
2200
2200
2200
95%
8800
2130
2130
2130
2130
8520
2200
8520
9970
620
2100
2690
2.8
9.6
12.3
4.06
A
2200
2200
2200
2900 102%
9500
1987
1987
1987
2619
8580
2200
8580 10040
620
2100
2690
2.8
9.6
12.3
4.09
A
2200
2200
2200
3800 112% 10400
1830
1830
1830
3161
8650
2200
8650 10120
620
2140
2740
2.8
9.8
12.5
4.04
A
2200
2200
2200
5600 131% 12200
1677
1677
1677
4269
9300
2200
9300 10900
620
2200
2820
2.8
10.1
12.9
4.23
A
2200
2200
2900
2900 110% 10200
1864
1864
2456
2456
8640
2200
8640 10100
620
2140
2740
2.8
9.8
12.5
4.04
A
2200
2200
2900
3800 119% 11100
1726
1726
2276
2982
8710
2200
8710 10190
620
2140
2740
2.8
9.8
12.5
4.07
A
2200
2200
2900
5600 139% 12900
1586
1586
2091
4037
9300
2200
9300 10900
620
2200
2820
2.8
10.1
12.9
4.23
A
2200
2200
3800
3800 129% 12000
1610
1610
2780
2780
8780
2200
8780 10270
620
2180
2790
2.8
10
12.8
4.03
A
2200
2900
2900
2900 117% 10900
1754
2312
2312
2312
8690
2200
8690 10170
620
2140
2740
2.8
9.8
12.5
4.06
A
2200
2900
2900
3800 127% 11800
1633
2153
2153
2821
8760
2200
8760 10250
620
2180
2790
2.8
10
12.8
4.02
A
2200
2900
3800
3800 137% 12700
1611
2124
2783
2783
9300
2200
9300 10900
620
2200
2820
2.8
10.1
12.9
4.23
A
2900
2900
2900
2900 125% 11600
2188
2188
2188
2188
8750
2200
8750 10240
620
2140
2740
2.8
9.8
12.5
4.09
A
2900
2900
2900
3800 134% 12500
2158
2158
2158
2827
9300
2200
9300 10900
620
2180
2790
2.8
10
12.8
4.27
A
2900
2900
3800
3800 144% 13400
2013
2013
2637
2637
9300
2200
9300 10900
620
2200
2820
2.8
10.1
12.9
4.23
A
E
Note
1. Cooling capacity is based on 27°C DB / 19°C WB (indoor temperature), 35°C DB (outdoor temperature).
2. Heating capacity is based on 20°C DB (indoor temperature), 7°C DB/6°C WB (outdoor temperature).
3. The above is the value for connecting with the following indoor units.
- 2.0, 2.6, 3.5kW class: Wall Mounted Style, MB, Vivace, Crystal Series
4. Capacities are based on the following conditions:
- Corresponding refrigerant piping length : 7.5m / - Level difference : 0m
5. Specifications are subject to change without prior notice for product improvement.
85
FJM AIR CONDITIONERS
S-NE T mini
S-NET mini supports up to 4 Data Management Servers to provide the same remote control
functions as S-NET3 and this touch screen controller can be connected directly with system air
conditioner through centralized controller or interface modules allowing up to 256 indoor units.
S-NET mini
Dynamic compatibility options
(DMS, centralized controller, interface module)
• Control and monitoring of up to 256 indoor units
• Detailed cycling information monitoring
• Schedule function (Weekly, Daily)
• USB keyboard support
• Error display
• 7-inch wide LCD display
• Temperature limit setting
• Touch screen
• Zone control
• Child-lock setting
• Operation mode lock
• External contact control
Supports
4 DMSs
Dynamic Compatibility Option
Supports
16
Centralized
Controllers
S-NET mini
16
Interface
Modules
86
Supports
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Centralized Control System
Centralized control system is more than enough to control multiple groups and
individual indoor units. With Samsung’s centralized controller, conveniently and
efficiently control the multiple or individual indoor units.
Control Systems Function Icon
Operation
Error
Error
ON/OFF, OPERATION MODE,
FAN SPEED, AIRFLOW,
TEMPERATURE SETTING
Group
INDIVIDUAL AND GROUP
CONTROL (MAXIMUM 16
INDOOR UNITS)
Filter
ERROR DISPLAY
FILTER REPLACEMENT
ALARM RESET
Centralized Controller
MCM-A202B
Maximum 16 group controls
(Maximum 256 Indoor units)
Unified/individual indoor unit control (On/Off)
Wireless/wired remote control restriction
Cooling/heating mode control
Indoor unit error display
MCM-A202B has compatibility with MCM-A202A
Function Controller
MCM-A100
Operation
Error
Error
Filter
Control and monitoring of up to 16 indoor unit groups
To use Function Controller, it requires to be connected to
MCM-A202A
Interface Module
MIM-B04A
Communicator between indoor/outdoor units and
the centralized controller
87
FJM AIR CONDITIONERS
Individual Control System
There is a variety of wired and wireless
controllers for convenient use of your
air conditioners. With different control
options, you can choose one that suits
your air conditioning environment.
Control Systems Function Icon
Operation
Group
ON/OFF, OPERATION MODE,
FAN SPEED, AIRFLOW,
TEMPERATURE SETTING
BUILT-IN ROOM
TEMPERATURE SENSOR
INDIVIDUAL AND GROUP
CONTROL (MAXIMUM 16
Lock
CHILD LOCK
INDOOR UNITS)
Error
Error
Filter
Auto Stop
ERROR DISPLAY
AUTOMATIC STOP MODE
FILTER REPLACEMENT
ALARM RESET
Wireless
Silent
Bright
SLEEP & SILENT MODE
WIRELESS REMOTE
CONTROL RESTRICTION
CLEAR & BRIGHT SCREEN
WITH LCD BACKLIGHT
Wired Remote Controller
MWR-WE00 (Multi function)
Operation
Group
Filter
Error
Error
Silent
Lock
Bright
Auto Stop
Wireless
Unified controller (A/C, ERV, A/C+ERV)
• Different permission levels
• Weekly schedule setting (A/C, ERV, A/C+ERV)
• Exception date setting
MWR-WH00
Lock
Operation
Auto Stop
Simple schedule control
Different permission levels
Wireless Remote Controller
MR-CH01
Operation
88
Silent
Filter
Simple schedule control
Wide display
Soft touch button
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Guest Room Management System
The Guest Room Management System is a smart way to save energy and
money. When the Key Tag is in place, the air conditioner is activated. When the
Key Tag is removed, the air conditioner switches off. Now you can avoid
cooling an unoccupied room and save energy.
External Contact Interface Module
MIM-B14
Direct indoor unit control by external contact signal
Window-synchronized indoor unit control
Emergency control with simple contact input
Indoor unit operation/error state output through
relay contacts
Example
On/Off
Key-Tag
On/Off
Window Open
Sensor
Error
On/Off
Malfunction
Alarm
External device
Control
(Wall mounted type indoor unit : Only the model including EEV supports state output function)
89
FJM AIR CONDITIONERS
Accessories
Classification
Integrated
Management
System
Controller
Interface
Module
Controller
Centralized
Control
System
Interface
Module
Individual
Control
System
Controller
Building Management
System
Guest Room
Management
System
Power Distribution
Image
Model
DMS2
MIM-D00A
DVM Series, FJM, CAC, ERV
S-NET3
MST-P3P
DVM Series, FJM, CAC, ERV
S-NET mini
MST-S3W
DVM Series, FJM, CAC, ERV
SiM
MIM-B12
DVM Series, FJM
Centralized Controller
MCM-A202B
DVM Series, FJM, CAC, ERV
Function Controller
MCM-A100
DVM Series, FJM, CAC
Operation Mode Selection Switch
MCM-C200
DVM Series (Except HR models)
MIM-B13B
Mini DVM(R410A), DVM PLUS II, DVM PLUS
II HR, DVM PLUS III, DVM PLUS III HR, FJM,
ERV
Centralized Control Interface Module
MIM-B04A
DVM, DVM PLUS, DVM HR, CAC
Wireless Remote Controller
MR-CH01
Cassette, Ceiling, Duct (Receiver
needed), Console (Included)
Wired Remote Controller (Multi Function)
MWR-WE00
Cassette, Wall Mounted, Ceiling,
Duct, Console
Wired Remote Controller
MWR-WH00
Cassette, Wall Mounted, Ceiling,
Duct, Console
Simplified Wired Remote Controller
MWR-SH00
Cassette, Wall Mounted, Ceiling,
Duct, Console
Wireless Signal Receiver
MRK-A00
Duct (For Wireless Remote Controller)
Receiver Wire
MRW-10A
Duct (For Wireless Remote Controller)
7-day Scheduler
MWR-BS00
Centralized Controller
External Room Sensor
MRW-TA
Cassette, Wall Mounted, Ceiling,
Duct, Console
Lonworks Interface Module
MIM-B07
DVM Series, FJM
Key-tag Interface Module
MIM-B02
DVM Series, FJM (Non MHFXEAB)
External Contact Interface Module
MIM-B14
CAC, Mini DVM(R410A), DVM PLUS II,
DVM PLUS II HR, DVM PLUS III,
DVM PLUS III HR, FJM(Non MHFKEA)
Power Distribution Unit
MCM-B102
DVM Series, FJM
Wireless Signal
Receiver Kit
DVM Series : Mini DVM, DVM, DVM PLUS, DVM HR, DVM PLUS II, DVM PLUS IIHR, DVM PLUS III, DVM PLUS IIIHR
90
Application Model
Product
2010 SAMSUNG RAC | CAC | FJM AIR CONDITIONERS
Icon Index
Wall-mounted Type Icon
Auto Roof Shutter
Virus Doctor generates Hydrogen
atoms and Oxygen ions to create
healthier air.
Air conditioner automatically seals
off to prevent dirt infiltration.
DNA Filter
Good’sleep II
The DNA structure possesses qualities in
absorbing and eliminating microscopic
carcinogenic agents.
Control the air temperature during your
sleep to enjoy a comfortable sleep and
refreshed wake up.
Cassette Type Icon
CEILING SOILING
PREVENTION
WIDE BLADE
Wider blades provide more
even cooling power.
WIDE
WIDE
Newly designed panel prevents
ceiling contamination.
HIGH LIFT-UP
DRAIN PUMP
HIGH
FRESH AIR INTAKE
FRESH
QUICK
Lift-up condensed water up
to 750mm higher than any
other competitor.
Optional air intake motor brings
in fresh air from outside.
SUB DUCT
QUICK CONNECTION
OF DRAIN PIPE
SUB DUCT
Unique drain pipe connection
is easy to install.
The Sub Duct makes it easy
to provide air conditioning to
a nearby smaller space.
Duct Type Icon
BACTERIA
ANTI-BACTERIA FILTER
EASY FILTER CLEANING
Anti-bacteria Filter traps dust
particles and suppresses proliferation
of moulds and bacteria.
Filter cleaning indicator will
let you know when the filter
needs to be cleaned.
SMART PRESSURE CONTROL
HIGH LIFT-UP DRAIN PUMP
HIGH
Lift-up condensed water up
to 750mm higher than any
other competitor.
WIRED REMOTE CONTROLLER
Adjusts fan speed to provide
constant cooling and heating
performance.
Wired
Default wired remote controller
is provided.
Floor & Convertible Type Icon
INTERIOR
DESIGN
Flexible Pipe
Installation
INTERIOR DESIGN
The clean, modern design
complements any decor.
ANTI-BACTERIA FILTER
BACTERIA
FLEXIBLE PIPE
INSTALLATION
The pipe can be installed
in 6 different places for
more placement options.
LIGHT
Anti-bacteria Filter traps dust
particles and suppresses
proliferation of moulds and bacteria.
Extremely lightweight, so
maintenance and installation
is easy.
SILENT MODE
Indoor and outdoor unit
operates silently.
AUTO CHANGEOVER
LIGHT WEIGHT UNIT
AUTO
Automatically changes operation
mode according to temperature
setting.
WIRELESS REMOTE
CONTOLLER
Wireless
Default wireless remote controller
is provided.
Control Systems Icon
Operation
Group
ON/OFF, OPERATION MODE,
FAN SPEED, AIRFLOW,
TEMPERATURE SETTING
Silent
SLEEP & SILENT MODE
Wireless
INDIVIDUAL AND GROUP
CONTROL (MAXIMUM 16
BUILT-IN ROOM
TEMPERATURE SENSOR
INDOOR UNITS)
Filter
FILTER REPLACEMENT
ALARM RESET
Error
Error
ERROR DISPLAY
Bright
Auto Stop
WIRELESS REMOTE
CONTROL RESTRICTION
CLEAR & BRIGHT SCREEN
WITH LCD BACKLIGHT
AUTOMATIC STOP MODE
Lock
CHILD LOCK
air conditioning centre
159 Edinburgh Avenue Slough SL1 4UE
Tel: 01753 495715 Fax: 01753 495716 Email: samsung@hrponline.co.uk
HRP Service Centres
HRP Limited – Bedford
Unit B6 Manton Centre Manton Lane Bedford
Milton Keynes MK41 7PX
Tel: 01234 272702 Fax: 01234 273424
Email: bedford@hrpltd.co.uk
HRP Limited – Birmingham
Units 16/17 Fulford Drive Minworth Industrial
Estate Sutton Coldfield B76 1DR
Tel: 0121 313 6720 Fax: 0121 313 2801
Email: birmingham@hrpltd.co.uk
HRP Limited – Bristol
100 The Quadrant Ash Ridge Road
Bristol BS32 4QA
Tel: 01454 456 430 Fax: 01454 456 431
Email: bristol@hrpltd.co.uk
HRP Limited – Newcastle
Unit K4 Hamar Close Tyne Tunnel Trading
Estate North Shields
Tyne and Wear NE29 7XB
Tel: 0191 258 3492 Fax: 0191 257 3982
Email: newcastle@hrpltd.co.uk
HRP Limited – Norwich
4/6 Murrayfield Road Fifers Lane Norwich
Norfolk NR6 6NQ
Tel: 01603 409616 Fax: 01603 400464
Email: norwich@hrpltd.co.uk
HRP Limited – Sheffield
Unit 2 Brightside 443 Brightside Lane
Sheffield South Yorkshire S9 2RS
Tel: 0114 244 8222 Fax: 0114 244 0400
Email: sheffield@hrpltd.co.uk
HRP Limited – Bury St Edmunds
Rougham Industrial Estate Bury St Edmunds
Suffolk IP30 9XA
Tel: 01359 270888 Fax: 01359 271770
Email: rougham@hrpltd.co.uk
HRP Limited – Slough
159 Edinburgh Avenue Slough SL1 4UE
Tel: 01753 495710 Fax: 01753 495711
Email: slough@hrpltd.co.uk
HRP Limited – Fareham
Unit 2 Stephenson Road Segensworth
Fareham Hampshire PO15 5RU
Tel: 01329 443515 Fax: 01329 443511
Email: fareham@hrpltd.co.uk
HRP Limited – Southampton
Unit 2 South Hampshire Industrial Park
Salisbury Road Totton Southampton SO40 3SA
Tel: 023 8086 9966 Fax: 023 8086 4205
Email: southampton@hrpltd.co.uk
HRP Limted – Glasgow
140 St Andrews Road Pollockshields
Glasgow G41 1 PP
Tel: 0141 420 1606 Fax: 0141 420 1755
Email: glasgow@hrpltd.co.uk
HRP Limited – Swanley
Teardrop Centre London Road Swanley
Kent BR8 8TJ
Tel: 01322 614811 Fax: 01322 614733
Email: swanley@hrpltd.co.uk
HRP Limited – Leeds
Unit 1 Aintree Court Hunslet Business Park
National Road Leeds LS10 1TF
Tel: 0113 277 5000 Fax: 0113 201 6201
Email: leeds@hrpltd.co.uk
HRP Limited – Walthamstow
Unit 12 Waltham Park Way Billet Road
Walthamstow London E17 5DU
Tel: 020 8531 9321 Fax: 020 8531 8155
Email: walthamstow@hrpltd.co.uk
HRP Limited – Merton
Unit 2 Saxon Business Centre Windsor
Avenue Merton London SW19 2RR
Tel: 020 8544 1010 Fax: 020 8544 9717
Email: merton@hrpltd.co.uk
HRP Limited – Warrington
5 Rivington Court Hardwick Grange
Warrington Cheshire WA1 4RT
Tel: 01925 837688 Fax: 01925 831093
Email: warrington@hrpltd.co.uk
www.samsungaccentre.com