ESP- Spindle - Installation PDF

ESP- Spindle - Installation PDF
R
O
R
O
TM
www.microiqlock.com
CORE REPLACEMENT LOCK
Installation Instructions
TriTeq Lock and Security
701 Gullo Ave
Elk Grove Village, IL 60007
ESP
Phone: (847) 640-7002
Toll Free: (888) 603-5625
Email: marketing@triteqlock.com
061515 - Rev. 5
FOR OFFICE FURNITURE, STORAGE CABINETS, LOCKERS, SAFES, VAULTS, SECURED ENCLOSURES
© Copyright 2014 TriTeq Lock and Security. All rights reserved
General dimensions
M3
7
3.86
8
#4
Fig. 1
1
#4
M3
M2
10
2
9
1 Knob
2 Cam stop
3 Lock Housing with keypad
1.00
4
5
6
7
8
9
10
11
12
13
.39
3
11
12
and infrared receiver
3M - VHB 4952 Foam tape (optional)
Spindle spacer
Spindle
Hex tool (1.5 mm)
Temper proof battery holder screw
CR2032 - 3 Volt Lithium Battery and battery holder
Mounting screws ( select one )
Mounting washer
Mounting nut
0.1” or 0.187” Lock spacers ( optional )
4
5
6
13
1
Installation
2
See Figure 1 for available mounting hardware for the MicroIQ. When mounting the MicroIQ to a
cabinet door or drawer, the existing handle or a separately mounted handle should be used to
operate, open and close the door or drawer.
Additional mounting fasteners (item 10) are provided and must be added through the battery
extremity of the housing. Select the fastener that best fits your panel material and thickness.
If drilling is required, use the drilling template provided at the end of this manual.
Double sided tape is also provided.
1
Insert the provided hex tool into the spindle
as shown.
Move the hex tool towards the arrow
indicated on the spindle until the retaining
tumbler is retracted.
Using your change key, remove the
existing lock core.
Note the position of the retaining
tumbler on the lock core removed
3
i.e.: 12 o`clock, 3, 6 or 9 o`clock position.
Insert the spindle with the retaining tumbler
in the same orientation as the original lock
core retaining tumbler.
Push the spindle into the lock shell until fully
seated.
You can purchase the change key online
at: www.easykeys.com
Example:
12 o`clock position
3
4
4
Remove the hex tool and confirm that the
spindle is captured into the shell by retaining
the tumbler.
6
Remove the knob and insert the provided
spindle spacer. Align the spline of the
spindle spacer with one valley from your
lock shell.
7
The MicroIQ can be mounted to the cabinet with
the enclosed screw or double stick tape or both.
The spindle is inserted properly when it can
not be removed from the housing.
5
Insert the knob. Exercise the knob and verify
that the spindle is engaged and operates
your locking mechanism as intended.
The installation template at the end of this
manual can be used to drill the mounting hole
for the MicroIQ. A wood screw and a
self-tapping metal screw are provided.
Remove the knob from the spindle with the
mechanism in the locked position.
1/8” diameter hole
for metal
3/32” diameter
hole for wood
6
51
Bezel
8
If the lock shell has a non-removable finish cup or a collar/bezel that would
restrict the MicroIQ from being inserted flush to the cabinet, use an
appropriate lock spacer in between the MicroIQ and the cabinet. Spacers of
0.1” ( P/N: 13081-00 ) and 0.187” ( P/N: 13081-10 ) are available from TriTeq.
The spacers are available in chrome and black finish. To select your preffered
finish, add the letter “C” for chrome or “B” for black to the end of the part
number. (e.g.: 13081-00-C )
Select appropriate mounting screw. If a lock spacer is required, a mounting
screw must be used.
Spindle
Spacer
Mount as shown on page 8.
Remove the backing from the foam tape (underneath the lock body) and insert
the MicroIQ in the desired orientation until it is flush with the face of your panel.
Lock
Spacer
Allow tape to cure for 72 hours.
7
8
9
11
OPTIONAL:
If your locking mechanism does not have a
rotational stop, insert one of the provided
cam stops to match the desired rotation.
Insert the knob at LOCKED position and
rotatate to verify that the cam stop was
positioned correctly.
Confirm that your mechanism is locked
when the knob points to the lock icon
9
12
If your locking mechanism requires the knob to rotate CCW from “locked”
to “unlocked”, rotate your knob only 45° and using the hex tool, fasten the
knob to the spindle from the indicated location.
13
If your locking mechanism requires the knob to
rotate CW from “locked” to “unlocked”, rotate your
knob only 45°. Using the hex tool, fasten the knob to
the spindle from the indicated location.
10
Battery
After installing the lock to the mounting surface, the battery and holder can be inserted
into the lock. The cover for the battery holder also serves to lock the holder into the lock
housing. The battery cover must be in the fully open position before inserting the holder.
The battery holder screw cannot be protruding from the bottom of the battery holder. It
must be flush with the holder so the holder can be inserted.
1
Battery
Holder
Check that the battery is properly inserted into the holder. The “+” surface of the
battery should be Inserted into the holder against the surface of the holder marked
with the “+” symbol. Insert the battery holder into the lock with the holder cover in the
fully open position and with the battery holder screw flush to the bottom of the holder
until the holder is fully seated. Next, use the hex tool to fasten the battery holder
screw into the lock body. Last, swing the battery holder cover to the closed position,
push in and fully seat the cover into the battery holder until it is flush to the lock body.
Battery
Cover
2
LIFT
UPWARD
3
4
Hex
Tool
Battery
Cover
Screw
SWING OVER
AND SNAP THE
COVER DOWN
If the battery is inserted while the knob is locked, you should hear the lock mechanism
click and the unit will lock. If the battery is inserted while the knob is unlocked, after
turning the knob to the locked position you should hear the lock mechanism click and
the unit will lock. If the unit will not lock after inserting the battery, enter the factory
code, move the knob to the unlocked position, and move the knob to the locked
position and you should hear the lock mechanism click and the unit will lock. If the
unit still does not lock, replace the battery.
11
12
Cleaning and Care:
To clean the MicroIQ surface, apply a non-acid based cleaner to a clean cotton
cloth. Do not spray cleaner directly on the MicroIQ. Wipe down the keypad and
housing surface of excess cleaner.
TriTeq Limited Warranty:
TriTeq offers a one year limited warranty on all products to be free from
manufacturing defects in materials and workmanship. This limited
warranty does not cover battery, lost combinations or damages caused by
improper mounting, operation or unreasonable use.
Liability Limits:
This is a limited warranty and in lieu of all other warranties (including the
implied warranties of merchantability and fitness of use) and under no
circumstances shall TriTeq Lock & Security or Hudson Lock, LLC be liable for
any incidental or consequential damages or losses.
Operating Temperature: 0 - +50 C
Storage temperature: -10 - +70 C
Operating Moisture: 20% - 80% Rh (without condensation)
Replacement Battery: 3 volt lithium CR2032
Battery Life: 5 years or more ( calculated at 20 uses per day )
ATTENTION: Battery life may vary with battery brand and environmental conditions.
Mounting Template
3.150
.75
1/8” diameter hole for metal
3/32” diameter hole for wood
1.00
Measure before drilling.
If the length of the segment is different from 1.00"
the template dimensions will be scaled accordingly
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF