ColorBlast 12 Powercore Data Sheet

ColorBlast 12 Powercore Data Sheet
ColorBlast 12 Powercore Data Sheet
CK INTELLIGENT SERIES
Preliminary
The ColorBlast® 12 Powercore fixture combines rich, saturated, wall-washing color and colorchanging effects with high performance, operational efficiency, and simplified installation.
Projecting a soft-edge beam of light, ColorBlast 12 Powercore is a sealed product designed
for both indoor and outdoor installations.
•
•
•
•
10° clear or 23° frosted glass lens
Low-profile mounting
Rugged, die-cast aluminum housing
Meets or exceeds specifications
for use in wet locations
• Attaches to standard junction
boxes
• Power and data delivered over a
single standard cable
• Versatile range of light positioning
offered with 350°, friction-free
rotation, a locking base swivel, and
110° locking fixture rotation
• Powercore® technology supports
100–240 VAC direct line voltage
input for simple installations
2
Preliminary
ColorBlast 12 Powercore Data Sheet
ColorBlast 12 Powercore Dimensions
SIDE
FRONT
31.7 cm
12.5 in
3.4 m
1.35 in
16.5 cm
6.5 in
18.2 cm
7.1 in
1.7 cm
0.65 in
12.1 cm
4.75 in
12.4 cm
4.9 in
16.5 cm
6.5 in
9.8 cm
3.9 in
SIDE
ColorBlast 12 Powercore Beam Angles
ColorBlast 12 Powercore is available with symmetric beam angles of 10 and 23 degrees.
10o
o
23
Philips Solid-State Lighting Solutions, Inc. • 3 Burlington Woods Drive • Burlington, MA 01803 • USA
Tel: 617.423.9999 • Toll Free: 888.385.5742 • Fax: 617.423.9998 • www.colorkinetics.com
ColorBlast 12 Powercore Specifications
Preliminary
3
ColorBlast 12 Powercore Specifications
See “Maximum Run Length” on page 7 for information on maximum fixture and cable runs.
ColorBlast 12 Powercore
Length
31.7 cm (12.5 in)
Width
16.5 cm (6.5 in)
Height
17.2 cm (7.1 in)
Weight
2.9 kg (6.4 lbs.)
LEDs Per Fixture
36 (12 red, 12 green, 12 blue)
Total Output (lumens)
725 lumens
Efficacy (Lm/W)
14.5
Source
High intensity RGB LEDs
Beam Angle
10º with clear lens; 23º ground lens
Housing
Die-cast aluminum; powder coated finish
Lens
Clear tempered glass or soft-focused tempered glass
Environment
UL Wet; IP66 (Suitable for wet locations)
Power / Data Connector 1.83 m (6-ft) unified power and data cable
Listings
UL/CUL, CE
Control
Philips Solid-State Lighting Solutions controllers or a
DMX512 (RS-485) source.
Operating Voltage
100 – 240 VAC, 50 – 60 Hz
Power Consumption
50W maximum, full-intensity, steady state
Temperature Range
-20°C to 50°C (-4°F to 122°F) starting temperature
-40°C to 50°C (-40°F to 122°F) operating temperature
Humidity Range
0 to 95% non-condensing
LED Source Life
50,000 hours, based on LED manufacturers’ test data
ColorBlast 12 Powercore Replacement Parts
These replacement parts are available for ColorBlast 12 Powercore.
Item Description
Item Number
UL, White, Frosted Lens
123-000009-00
UL, Black, Frosted Lens
123-000009-01
CE, White, Frosted Lens
123-000009-02
CE, Black, Frosted Lens
123-000009-03
UL, White, Clear Lens
123-000009-04
UL, Black, Clear Lens
123-000009-05
CE, White, Clear Lens
123-000009-06
CE, Black, Clear Lens
123-000009-07
UL, White, Narrow Optics
123-000009-08
UL, Black, Narrow Optics
123-000009-09
CE, White, Narrow Optics
123-000009-10
CE, Black, Narrow Optics
123-000009-11
Philips Solid-State Lighting Solutions, Inc. • 3 Burlington Woods Drive • Burlington, MA 01803 • USA
Tel: 617.423.9999 • Toll Free: 888.385.5742 • Fax: 617.423.9998 • www.colorkinetics.com
4
Preliminary
ColorBlast 12 Powercore Data Sheet
ColorBlast 12 Powercore — Clear Lens Photometrics
The photometric data presented in each graph is measured in
footcandles and lux (in parentheses) and is based on test results
from an independent testing lab. IES files are available at http://
www.colorkinetics.com/support/ies.
Candle Power Distribution
The broken line marking x candela is 50% of peak (FWHM).
The tested fixture has these specifications:
Voltage
Optics
Illustration to come later
Lens
Data to come later
Source
Beam Angle
Distribution
Illuminance Distribution, Illuminance, and Beam Angle
The distribution illustration below represents the plane x cm (x ft) from the
fixture in the Illuminance and Beam Angle diagram, right, which shows the
measurement of the center beam.
Illustrations to come later
Philips Solid-State Lighting Solutions, Inc. • 3 Burlington Woods Drive • Burlington, MA 01803 • USA
Tel: 617.423.9999 • Toll Free: 888.385.5742 • Fax: 617.423.9998 • www.colorkinetics.com
ColorBlast 12 Powercore — Ground Lens Photometrics
Preliminary
5
ColorBlast 12 Powercore — Ground Lens Photometrics
The photometric data presented in each graph is measured in
footcandles and lux (in parentheses) and is based on test results
from an independent testing lab. IES files are available at http://
www.colorkinetics.com/support/ies.
Candle Power Distribution
The broken line marking x candela is 50% of peak (FWHM).
The tested fixture has these specifications:
Voltage
Illustration to come later
Optics
Lens
Data to come later
Source
Beam Angle
Distribution
Illuminance Distribution, Illuminance, and Beam Angle
The distribution illustration below represents the plane x cm (x ft) from the
fixture in the Illuminance and Beam Angle diagram, right, which shows the
measurement of the center beam.
Illustrations to come later
Philips Solid-State Lighting Solutions, Inc. • 3 Burlington Woods Drive • Burlington, MA 01803 • USA
Tel: 617.423.9999 • Toll Free: 888.385.5742 • Fax: 617.423.9998 • www.colorkinetics.com
6
Preliminary
ColorBlast 12 Powercore Data Sheet
ColorBlast 12 Powercore — Narrow Optic Photometrics
The photometric data presented in each graph is measured in
footcandles and lux (in parentheses) and is based on test results
from an independent testing lab. IES files are available at http://
www.colorkinetics.com/support/ies.
Candle Power Distribution
The broken line marking x candela is 50% of peak (FWHM).
The tested fixture has these specifications:
Voltage
Optics
Illustration to come later
Lens
Data to come later
Source
Beam Angle
Distribution
Illuminance Distribution, Illuminance, and Beam Angle
The distribution illustration below represents the plane x cm (x ft) from the
fixture in the Illuminance and Beam Angle diagram, right, which shows the
measurement of the center beam.
Illustrations to come later
Philips Solid-State Lighting Solutions, Inc. • 3 Burlington Woods Drive • Burlington, MA 01803 • USA
Tel: 617.423.9999 • Toll Free: 888.385.5742 • Fax: 617.423.9998 • www.colorkinetics.com
ColorBlast 12 Powercore Installation Details
Preliminary
7
ColorBlast 12 Powercore Installation Details
Mounting Options
ColorBlast 12 Powercore is designed to
be mounted to a junction box.
The fixture is shipped with a gasket for
outdoor use. See Figure 1 for assembly
information. There is no need to include
the gasket for indoor use.
Rotation
set screw
Tilting
set screws
Figure 2: Aiming the ColorBlast 12 Powercore Fixture. Rotate the fixture and then
secure the angle using the two set screws.
Figure 1: Assemble the fixture as shown;
insert the gasket if the fixture is to be used
outdoors.
After aiming the fixture, secure the
rotation using the two set screws. See
Figure 2.
Wiring
From Power Source
D
L
L
N
N
G
G
DMX OUT
To Lights
DMX/ETHERNET IN
Figure 3: ColorBlast 12 Powercore Wiring: In Series.
The ColorBlast 12 Powercore fixture is
connected to a junction box and can be
wired either in an interconnected series
or in parallel. See Figures 3 and 4.
Maximum Run Length
Run length is determined by a
combination of line voltage, circuit load,
voltage drop, and leader and jumper
cable lengths. Download the calculator
at www.colorkinetics.com/support/
install_tool to record the variables and
to generate the maximum number of
fixtures.
In a typical installation using a 18.3 m
(60-ft), 12 AWG leader cable with 12
AWG and 1.5 m (5 ft) of cable between
fixtures, each data enabler can support
up to 25 fixtures at 120 VAC (15A), 34
fixtures at 120 VAC (20A), or 60
fixtures at 240 VAC (20A).
Figure 4: ColorBlast 12 Powercore Wiring: In Parallel.
Philips Solid-State Lighting Solutions, Inc. • 3 Burlington Woods Drive • Burlington, MA 01803 • USA
Tel: 617.423.9999 • Toll Free: 888.385.5742 • Fax: 617.423.9998 • www.colorkinetics.com
8
Preliminary
ColorBlast 12 Powercore Data Sheet
This product is protected by one or more of the following U.S. patents and their foreign counterparts: 6,016,038, 6,150,774,
6,340,868, 6,636,003, 6,777,891, 6,788,011, 6,806,659,
6,969,954, 6,975,079, 7,186,003, 7,221,104, 7,256,554 and
7,274,160. Other patents pending.
DAS-000008-00 R00 2008-04-07
Copyright © 2008 Philips Solid-State Lighting Solutions, Inc. All
rights reserved.
Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the
Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ColorCast, ColorPlay, DIMand, Direct Light, EssentialWhite, eW, iColor,
iColor Cove, IntelliWhite, iW, iPlayer, Light Without Limits,
Optibin, Powercore, Sauce, the Sauce logo, and Smartjuice are
either registered trademarks or trademarks of Philips Solid-State
Lighting Solutions, Inc. in the United States and/or other countries.
All other brand or product names are trademarks or registered
trademarks of their respective owners.
Philips Solid-State Lighting Solutions, Inc. • 3 Burlington Woods Drive • Burlington, MA 01803 • USA
Tel: 617.423.9999 • Toll Free: 888.385.5742 • Fax: 617.423.9998 • www.colorkinetics.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising