Installation and wiring guide

Installation and wiring guide
iT600 Wiring Centre KL10 010.qxp_Layout 1 23/03/2015 12:14 Page 1
KL10
Installation and wiring guide
PROGRAMMABLE
ROOM THERMOSTAT PRT
MODEL VS10W
OPTIONAL
HOT WATER TIMER
MODEL VS10W
GROUP 2 CONTROL
THERMOSTAT
MODEL VS10W
GROUP 2
THERMOSTAT
GROUP 2
THERMOSTAT
GROUP 2
DIAL THERMOSTAT
GROUP 1
DIAL THERMOSTAT
OPTIONAL
PRT (RADIATORS)
GROUP 1 CONTROL
THERMOSTAT
2
8
+
2
1 SL L
N
+
2
1 SL L
+
N
1 SL L
2
+
N
1 SL L
2
+
N
2
1 SL L
+
N
1 SL L
2
+
N
2
1 SL L
+
N
2
1 SL L
+
N
2
1 SL L
N
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
0.5MM 2
TWIN
1.5MM 2 3 CORE
1
OPTIONAL
OPTIONAL
1.5MM 2 3 CORE
0.5MM 2 TWIN
1.5MM 2 CABLE
(INSTALLER SUPPLIED)
FACTORY
FITTED
LINK
230V
2
1.5MM CABLE
COLOURS ARE INDICATIVE ONLY.
EXTRA CONNECTIONS MAY BE REQUIRED
AS PER MANUFACTURERS INSTRUCTIONS
OUT
IN
(INSTALLER SUPPLIED)
6
IN OUT
HW CYLINDER
THERMOSTAT
BR EA N
OR GR
HW MOTORISED VALVE
IN OUT
L
OVERHEAT STAT
N
UFH PUMP
E
IN OUT
BR EA N
BOILER ENABLE
FACTORY
FITTED
LINK
FACTORY
FITTED
LINK
OR GR
IN OUT
UFH MOTORISED VALVE
3
9
FUSE
HEETING/
COOLING
4
OUT
IN
FUSE
5
SL N L
HOT WATER
7
L
SL N L
ZONE 1
N L
N
ZONE 1
OPTIONAL
CYLINDER STAT
SL N L
ZONE 2
L
N L
SL N L
ZONE 3
N
ZONE 2
L
N L
SL N L
ZONE 4
N
ZONE 3
L
N L
SL N L
ZONE 5
N
ZONE 4
L
N L
SL N L
ZONE 6
N
ZONE 5
L
N L
SL N L
ZONE 7
N
ZONE 6
L
SL N L
ZONE 8
N L
N
ZONE 7
+ + + + GROUP 2
L
5
N L
-
-
+ + + +
GROUP 1
N
ZONE 8
Meets the following EC Directives
• Electro-Magntic Compatibility directive 2004 / 108 / EC
• Low voltage Directive 2006/95/EC
2
1.5MM CABLE (INSTALLER SUPPLIED)
1.5MM 2 CABLE
(INSTALLER SUPPLIED)
SUPPLIED CABLES
These instructions are applicable to the SALUS model
stated on the front cover of this manual only.
2
OPTIONAL UFH ZONE VALVE
FOR RADIATORS GROUPS
Warning
13 AMP FUSED CONNECTION UNIT
FUSED AT 3 AMPS
This product must be fitted by a competent person, and
installation must comply with the guidance, standards and
regulations applicable to the city, country or state where the
product is installed. Failure to comply with the requirements
of the relevant guidance, standards and regulations could lead
to injury, death or prosecution.
UNDERFLOOR HEATING MANIFOLD
Warning
230V TO UFH PUMP
1.5MM 2 CABLE (INSTALLER SUPPLIED)
Always isolate the AC Mains supply before installing or working
on any components that require 230 VAC 50Hz supply.
For PDF Installation guide please go to www.salus-controls.com
www.salus-controls.com Technical Helpline +49 610 8825 8515
Maintaining a policy of continued product development SALUS Controls plc reserve the right to change
specification, design and materials of products listed on this installation guide without prior notice.
Issue Date: June 2014 Document Number 00105
iT600 Wiring Centre KL10 010.qxp_Layout 1 23/03/2015 12:15 Page 2
KL10
Installation and wiring guide
1
Hot Water Connections
6
OPTONAL UPH
MOTORISED
VALVE REMOVE
LINK IF USED
OPTONAL HOT
WATER
MOTORISED
VALVE
Option 1
Connect Cylinder
Thermostat to
wiring centre
IN OUT
HW CYLINDER
THERMOSTAT
BR EA N
OR GR
HW MOTORISED VALVE
IN OUT
L
OVERHEAT STAT
N
E
UFH PUMP
IN OUT
BOILER ENABLE
BR EA N
OR GR
UFH MOTORISED VALVE
THERMOSTAT CONNECTIONS 230V AC
230V AC
ZONE 1
SL N L
HW TIMER CONNECTION
SL N L
ZONE 2
SL N L
ZONE 3
SL N L
OPTONAL HOT
WATER
MOTORISED
VALVE
ZONE 4
SL N L
OPTONAL UPH
MOTORISED
VALVE REMOVE
LINK IF USED
3
Motorised Valves, Pump, Boiler & Stat Connections
Optional Cylinder Thermostat: If connecting the cylinder thermostat
directly to the timer then a link needs to be fitted between IN and OUT.
Optional Hot Water Motorised Valve: Used if timed hot water is required.
Optional Overheat Thermostat: Used for connecting a pipe thermostat to
prevent over temperature water damaging sensitive floors. Remove the link
and connect the pipe thermostat so it is Normally Closed. The pipe stat will
open if overheating occurs and
the UFH pump will stop running.
Optional Boiler Enable: This Volt Free connection must come from the boiler
thermostat connection, when any zone calls for heat the Boiler enable will
close causing the boiler to run. If work is being carried out on the boiler then
power to and from the switch will cease. (Do not connect to the boiler IN
terminal by linking a 230V feed from the wiring centre)
Optional UFH Motorised Valve: If a UFH motorised valve is
fitted then remove the link between OR and GR.
Optional Heat/Cool Changeover: This connection allows heat/cool
changeover of all thermostats using a single external switch (installer supplied).
Switch: Open-Heating Closed-Cooling
Ribbon Connection
This must be carefully removed
or replaced when removing or
replacing the wiring centre cover,
being careful to ensure the
correct orientation. Ensure the
side coloured red on the ribbon
cable aligns with the red dot on
the wiring centre.
Option 2
Connect Cylinder
Thermostat to RF
Thermostat for wire
free connection. A
link will be needed
between IN & OUT
as shown by arrow.
5
IN OUT
HW CYLINDER
THERMOSTAT
BR EA N
OR GR
HW MOTORISED VALVE
230V AC
HW TIMER CONNECTION
SL N L
IN OUT
L
OVERHEAT STAT
N
UFH PUMP
E
IN OUT
BOILER ENABLE
BR EA N
OR GR
UFH MOTORISED VALVE
IN
HEET
COO
THERMOSTAT CONNECTIONS 230V AC
ZONE 1
SL N L
ZONE 2
SL N L
ZONE 3
SL N L
ZONE 4
SL N L
SL
Sensor Terminals
Can be used for external AIR,
Floor sensor when configured
as thermostat. Can also be
used for cylinder thermostat
when connected for HW.
Thermostat Grouping
The thermostats can work as individual units or in groups. There can be up to 2 groups of
thermostats per wiring centre. In order to work in groups the communications cable must be
connected to the wiring centre communications terminals (+ & -). The (-) terminals are
common to all thermostats. In order to assign the thermostat to group 1 or 2 then the
communications cable + must be connected to the relevant 1 or 2 + terminal.
When using option 2 refer to device
parameters on page 40 of the manual.
8
Fuses
Thermostat Zones
4
Dip Switch Set Up
In order for the wiring centre to be able to control UFH
and Radiators, there is a need to turn off the UFH pump for
a zone when that zone is to be used for radiators.
Eg. When fitting a zone for radiators or towel rail then the
Dip Switch for that zone should be switched to OFF.
The Dip Switches for this are located under the front lid.
When the zone switch is in the ON position the UFH pump
will run when that zone is calling for heat along with the
boiler. When it is in the OFF position then the UFH pump will
not run but the boiler will fire.
There are three other function switches as well.
Pump & Boiler delay: This gives a three minute delay to
allow actuators to open before the boiler fires.
Pump Only Delay: Delays only the UFH pump from firing
for three minutes.
Actuator NC or NO: This refers to Normally Open or
Normally Closed. This should be set to NC for JG products.
Status Neon’s
8
Groups
1
2
2
If hot water is part of a group then
the communication connection
must be connected to group 1.
7
Actuator Connections
Actuator connections corresponding to the thermostat
connections. Up to 2 cables can be used in each
connection (4 Actuators per Zone) If more, that number
needs to be connected, then an external junction box
will be needed. A maximum of xxx actuators can be
connected to a zone in this manner.
www.salus-controls.com Technical Helpline +49 610 8825 8515