air conditioner/dehumidifier 9000btu/hr

air conditioner/dehumidifier 9000btu/hr
instructions for
air conditioner/dehumidifier 9000btu/hr
model no: SAC9001
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
instruction
manual
1. SAFETY
1.1. Electrical Safety
‰‰ WARNING! It is the user’s responsibility to check the following:
1.1.1.Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all
electrical connections for wear and damage. Ensure the risk of electric shock is minimised by the installation of appropriate safety
devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We recommend that an
RCD (Residual Current Device) is used with all electrical products. It is particularly important to use an RCD with portable products
that are plugged into a supply not protected by an RCCB. If in doubt consult a qualified electrician. You may obtain an RCD by
contacting your local Sealey dealer.
Electrical safety information, it is important that the following information is read and understood.
1.2. The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.2.1.The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.2.2.Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and use a
Portable Appliance Tester.
1.2.3.Ensure that cables are always protected against short circuit and overload.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct
fuse - see fuse rating in these instructions.
88 DO NOT pull or carry the appliance by the power cable.
88 DO NOT pull the plug from the socket by the cable. Remove the plug from the socket by maintaining a firm grip on the plug.
88 DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or replaced immediately by a qualified electrician.
1.3. This product is fitted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged, remove from use and ensure that repairs are carried out by a
qualified electrician.
Replace a damaged plug with a BS1363/A 13A 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires and ensure that wires have been correctly connected.
Ensure that the cable outer sheath extends beyond the cable restraint and that the restraint is tight.
Double insulated products are marked with the Class II symbol.
Class II products are wired with live (brown) and neutral (blue) only. To rewire,
connect the wires as indicated in diagram.
Recommended fuse rating
DO NOT connect either wire to the earth terminal.
13Amp
Products which require more than 13 amps are supplied without a plug. Contact a qualified electrician
to ensure that a suitably rated supply is available. Ensure that an industrial round pin plug and socket are
fitted by a qualified electrician.
If an extension cable reel is used, ensure that it is fully unwound before connection. Use a reel that includes an RCD, an appliance will be protected by the RCD. The cable core section is important and should be at least 1.5mm². Ensure that the cable of the reel is appropriate for this product. We recommend the use of 2.5mm² core section cable.
1.4. General Safety
99 Check that the unit is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
99 Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
88 DO NOT stand or place any object closer than 500mm from the unit.
88 DO NOT obstruct the air intakes or outlets of the unit, and do not cover with washed clothes.
88 DO NOT place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.
88 DO NOT operate the unit when you are tired or under the influence of alcohol, drugs or intoxicating medication.
88 DO NOT switch the unit off by disconnecting it from the mains. ALWAYS switch to the “OFF” position first.
88 DO NOT remove the float lever from the water collection tank.
© Jack Sealey Limited
Original Language Version
SAC9001 | Issue 3 (L) 29/11/16
88
99
99
99
88
99
99
99
99
DO NOT connect or disconnect the plug from the mains with wet hands.
Always discard the water from the collection tank, DO NOT use it for any other purpose.
Place the unit on a level and stable surface.
To prevent water from freezing, do not use the unit at ambient temperatures below 0°C.
DO NOT use the unit outside.
Ensure that heating appliances are not exposed to the flow of air from the unit.
Before attempting to move the unit, empty the contents of the water tank. See section 8 for instructions on moving.
Switch off and disconnect unit from the mains before attempting any cleaning or other maintenance work.
Ensure that the unit is turned off correctly when not in use, and stored in a safe, dry area, out of reach of children. See section 9.
NOTE: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
2. introduction
Thermostatically controlled unit with extendible exhaust hose and window kit - ideal for home or office environments. Features two-speed
fan and electronic remote control. Air conditioning temperature range 17-30°C. Also features a dehumidifying function capable of removing
up to 24ltr/day. Refrigerant is R410A. Mounted on castors for manoeuvrability. Cable storage keeps unit tidy when not in use.
3. specification
Model No:. . . . . . . . . . . . . . . . . . . . . . . . . . . . SAC9001
Cooling Capacity: . . . . . . . . . . . . . . . . . . . . .9000Btu/hr
Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 999W
Maximum Air Flow:. . . . . . . . . . . . . . . . . . . . .380mtr³/hr
Maximum Water Extraction Rate:. . . . . . . . . . . 24ltr/day
Refrigerant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R410A
Discharge Side Pressure.. . . . . . . . . . . . . . . . 3.6MPa
Suction Side Pressure . . . . . . . . . . . . . . . . . . . 1.2MPa
Exhaust Hose Length. . . . . . . . . . . . . . . . . . . .1500mm
Energy Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22kg
1. Control panel. 2. Horizontal louvre. 3. Vertical louvre. 4. Air outlet frame. 5. Vertical Louvre connecting lever. 6. Caster. 7. Top cap. 8. Horizontal louvre connecting lever. 9. Main vertical louvre. 10. Front shell. 11. Handle / Remote Control Storage. 12. Back shell. 13. Retaining clamp. 14. Power cord. © Jack Sealey Limited
15. Air duct.
16 Wire-winding posts.
17. Drain cap.
18. Evaporator filter mesh.
19. Evaporator filter frame.
20. Radiating fine mesh.
21. Condenser filter mesh.
22. Condenser filter frame.
23. Base plate.
24. Window sealing board assembly.
25. Window sealing board.
26. Exhaust Hose.
27. Connector.
28. Remote control.
Original Language Version
SAC9001 | Issue 3 (L) 29/11/16
4. installation
‰‰ WARNING! leave this mobile air-conditioner in an upright position for at least 2 hours before first use. Ensure that the air conditioner
remains in an upright position whilst it is being moved. Place the air-conditioner on a flat ground surface.
4.1. Connector 25 and Window Sealing Board Assembly 28 are fitted to Exhaust Hose 26. Place 25 and 26 at each end of the hose and screw clockwise onto the hose to connect.
Exhaust hose Retaining Clamp assembly;
4.2. Select the exhaust hose retaining clamp.
4.3. Fit the exhaust hose to the circular aperture at the rear and secure with the retaining clamp. Rotate the retaining clamp anticlockwise
and snap the retaining clamp closed to secure the Heat Exhaust Hose.
4.4. Fit 27 window sealing board to the window as shown in Fig 1 (vertical) or Fig 2 (horizontal).
Fig.1
4.5. Fig.2
Position the mobile air-conditioner, with the exhaust hose assembly attached, near to a window. Keep the mobile air conditioner at least 50cm away from the walls or other objects. (As shown in Fig 3)
Fig.3
4.6. Snap the flat end of the exhaust hose connector into the elliptical hole of the window sealing board assembly (as shown in Fig 4 and Fig 5).
4.7. To ensure adequate operation, ensure that the exhaust hose is not kinked, do not bend the exhaust hose any more than 45°.
‰‰ Important:
The exhaust hose is 280mm-1500mm long and this length is determined based on the specification of the air-conditioner (s). Do not use hoses with other specifications. Do not replace with non-genuine components as this may affect the functions of the air-conditioner. The flow of exhaust must be smooth. Obstructed exhaust may cause the air-conditioner to overheat.
© Jack Sealey Limited
Original Language Version
SAC9001 | Issue 3 (L) 29/11/16
5. operation
Fig.4
Fig.5
5.1. Function setting
This air conditioner has 3 functions: cooling, dehumidifying and fan.
5.2. Control keys
Power key: press to turn on/off.
Mode key: sets Cooling, Dehumidifying and Fan modes.
Fan speed: press to select high/low fan speed (not available in dehumidifying mode.)
Timer key: when setting the time the Regular Time Indicator will light.
Up/Down key: press these buttons to set the desired room temperature and time.
Switch between °C and °F by pressing these two keys simultaneously or by using the remote control.
5.3. Operation
5.3.1.
Cooling mode:
Ta≥Ts +1°C (1°F), the cooling will start.
Ta≤Ts -1°C (1°F), the compressor stops and only the fan motor remains working at the set fan speed.
Ta: Room Surrounding Temperature
Ts: Setting Temperature
In this mode, press Timer and Down button to set sleep function, In sleep function, after operating two hours, the set temperature increases 1°C (1°F) automatically.
After operating for another 2 hours, the set temperature will increase 1°C (1°F) again. Then the set temperature will not change and the fan will switch to low level.
5.3.2.
Dehumidifying mode:
If the ambient temperature ≥17°C (62°F), the compressor will start. Then, the unit is controlled in the following manner:
When the ambient temperature ≤15°C (59°F), the compressor shuts down.
When the ambient temperature rises to be ≥17°C (62°F), the compressor starts again. The start/stop of the compressor meets the requirement for 3-minute protection time.
5.3.3.
Fan mode:
Fan runs on both high speed or low speed. Temperature setting displays environment temperature between 0 / 35°C (50 / 95°F).
© Jack Sealey Limited
Original Language Version
SAC9001 | Issue 3 (L) 29/11/16
5.3.4.
Timer setting:
a) Upon start, press the Timer button to enter timed shutdown. Upon shutdown, press this button to enter timed start. The timer indicator will illuminate.
b) Press the Timer button to enter the timing function (timed start/timed shutdown). Adjust the up or down button to set the timing time.
The time will cycle in the order of
1-2-3-……....24 0 - 1 hours or
24-23-22-……1 0 - 24 hours.
c) After timed start is set, once the timed start time is reached, the unit will start.
In the meantime, the timer indicator will extinguish and the ambient temperature is displayed.
d) After timed shutdown is set, when the shutdown time is reached the unit will shut down.
In the meantime, the timer indicator will extinguish and the ambient temperature is displayed.
e) Only the final setting of the timing function is activated. This setting is for one operation.
f) ON/OFF selection on the Control Panel or Remote Control will clear all timing settings.
g) Once the timing is determined, if the timer button is pressed once, it is possible to query the
remaining timed start/shutdown time. If the timer button is pressed twice continuously within 5
seconds, the timing will be cancelled.
5.4. Remote control operating instructions
Power button: press this button to turn on/off the unit;
Timer button: upon shutdown, press this button to set timed start; upon start, press this button to
set timed shutdown.
High button: press this button to allow the unit to operate in the high fan speed state (except in
the dry and sleep modes);
Low button: press this button to allow this unit to operate in the low fan speed state;
Up button: press this button to increase the temperature and timing value;
Down button: press this button to decrease the temperature and timing value;
°C — F button: press this button to switch between the Celsius and Fahrenheit;
Cool button: press this button to set this unit to operate in the cooling mode.
Fan button: press this button to set this unit to operate in the air supply mode.
Dry button: press this button to set this unit to operate in the dry mode.
Sleep mode: press this button to set this unit to operate in the sleep mode.
5.5. Antifreeze protection function
Upon cooling, when the compressor operates continuously for more than 10 minutes, if the pipe temperature Tp is less than or equal to 2°C continuously for 20 seconds, the compressor and water spraying motor turn off, other loads operate and LED displays E4.
The unit initiates the anti-frost protection function and the buttons are inactive (except the OFF button). Once the pipe temperature rises to exceed or equal 8°C, the protection is relieved, the original status is restored and the unit meets the requirements for 3-minute delay protection of the compressor.
5.6. Full water protection function
When the water in the water tray exceeds the alarm level, the unit will alarm automatically and the full water indicator illuminates.
Drain the condensate in the unit; otherwise, the unit will shut down automatically after the buzzer gives off 5 beeps.
(For more information about the drain method, refer to Section 6. If the unit is not shut down manually, the unit will be restored to the
previous operating status automatically once the water is fully drained. Or the power may be turned on again to start the unit.
5.7. Delay protection function of the compressor
This unit offers restart protection for the compressor. Except that the compressor may start immediately when the unit is energized for the first time, there is 3 minute delay start protection after the compressor is shut down.
6. water drainage
6.1. Manual drain (Fig 6)
The unit will shut down when the water level is full.
Turn off the power and unplug the power cable.
Note: move the unit carefully to avoid spillage of water in the water tray at the bottom of the unit.
Place a vessel beneath the water outlet, at the back of the unit, to drain water.
Unscrew the drain cap and remove the water plug to allow water to flow into the vessel.
Note: Protect the drain cap and water plug from becoming detached. Tilt the unit slightly backward when draining.
Fig.6
© Jack Sealey Limited
Original Language Version
SAC9001 | Issue 3 (L) 29/11/16
6.2. Continuous drain
6.2.1.
Unscrew the water cap in the direction shown by the arrow and unplug the water plug;(Fig 7)
6.2.2. Attach a drain hose onto the water outlet; (Fig 8)
6.2.3.
Connect the drain hose to a suitable drainage point.
Note: The drain hose must be installed when there is no water in the baseplate;
6.2.4.
When operating in the cooling mode, to ensure the water for radiation of the condenser of the unit and to enhance the cooling effects of the unit, it is recommended that continuous drain is not be set when the unit is in use;
6.2.5.
When operating in the heating mode, use continuous drain; otherwise, the unit may shut down due to water level becoming full. Place the drain hose at a height that is not above the water outlet.
6.2.6.
Prevent the drain hose from becoming kinked.
6.2.7.
When continuous drain is in use, keep the drain cap and water plug closed.
Fig.7
Fig.8
7. maintenance & servicing
Note: Disconnect from the mains before carrying out any servicing or maintenance.
7.1. Clean the surface of the unit with wet soft cloth. Do not use chemical solvents as these may damage the unit.
7.2. Filter Frame and Filter Mesh cleaning
7.2.1.
Clean the filter mesh once every two weeks.
7.2.2.
If the filter frame and filter mesh are clogged with dust, the function of the air-conditioner may decrease.
7.2.3.
Remove the evaporator filter frame and the condenser filter frame gently in the direction shown by the arrow (as shown in Fig 9).
7.2.4.
Remove the evaporator filter mesh and condenser filter mesh gently in the direction shown by the arrow (as shown in Fig 10).
7.2.5.
Remove the filter frame first and then take out the filter mesh.
Note: when taking out the filter frame or filter mesh, the force shall be applied evenly to avoid twisting or damage of the filter frame or filter mesh.
7.2.6.
Place the evaporator filter frame, condenser filter frame, evaporator filter mesh, and condenser filter mesh into warm water (about 40°C). Use neutral cleaner. Dry in the shade. (Fig 11)
Fig.10
Fig.11
Fig.12
Fig.9
Note: Do not damage the mesh fabric on the filter frame and filter mesh.
7.3. Installation of the filter frame and filter mesh
7.2.7.
Install the filter mesh first and then install the filter frame.
7.2.8.
To install the evaporator filter mesh and condenser filter mesh, point the back end of the filter mesh toward the socket and then push the filter mesh evenly and gently into the socket.
Note: Install the filter mesh in the reverse order of removal. The filter mesh must be installed into place; otherwise, the filter frame may not be installed into place.
© Jack Sealey Limited
Original Language Version
SAC9001 | Issue 3 (L) 29/11/16
7.3. Cleaning of the handle position and remote control storage area
7.4. Remove the remote control from the storage area (Fig 12).
7.5. Clean the handle position and remote control storage area with damp soft cloth only. DO NOT allow water to drip into the unit. DO NOT soak the cleaning cloth.
8. moving the unit
8.5.1.To move the unit, hold the top of the air outlet on the front of the unit with one hand and the handle position at the top of the back of the unit with another hand, (Fig 13). Ensure that the unit remains upright. DO NOT hold the horizontal louvre by hand.
8.5.2.Leave the unit in the upright position when handling or moving it.
8.5.3.
To handle or move the unit, drain the water in the unit first to prevent the water in the unit from flowing onto the ground or carpet.
8.5.4.If the remote control is in the position of the handle, take out the remote control, (Fig 14).
Fig.13
Fig.14
9. storage
9.1. Unscrew the drain cap, unplug the water plug and drain the water in the water tray to a suitable vessel.
Note: DO NOT tilt the unit any further than 30° from vertical.
9.2. Start the unit, adjust mode to the low fan speed setting, keep the unit in this state for half a day in order to dry the interior of the unit to prevent mould.
9.3. Turn off the unit, unplug the power plug, wrap the power cord around the wire-winding post, insert the plug into the storage point on the rear of the unit; install the water plug and drain cap.
9.4. Remove the exhaust hose assembly and store appropriately to prevent damage.
Note: to remove the exhaust hose assembly, hold the handle of the exhaust hose retaining clamp, pull the retaining clamp outward
evenly, rotate the retaining clamp clockwise to open. Remove the exhaust hose assembly.
9.5. Pack the air-conditioner in a soft plastic bag. Store the unit in a dry and dust proof place. Keep the unit out of the reach of children.
9.6. Remove batteries from the remote control. Store remote control in an appropriate place.
9.7. Ensure that the unit is stored in a dry place.
10. troubleshooting
Repairs should be carried out by suitably qualified persons only.
© Jack Sealey Limited
Original Language Version
SAC9001 | Issue 3 (L) 29/11/16
Battery Removal
Remove battery from remote.
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential
purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack Sealey Ltd’s Batteries Producer Registration Number (BPRN) is BPRN00705.
Environmental Protection
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.
When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)
into approved containers and dispose of the product and the fluids according to local regulations.
WEEE Regulations
Dispose of this product at the end of its working life in compliance with the EU Directive on
Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed
of in an environmentally protective way. Contact your local solid waste authority for recycling information.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
© Jack Sealey Limited
Original Language Version
01284 757500
www.sealey.co.uk
01284 703534
sales@sealey.co.uk
SAC9001 | Issue 3 (L) 29/11/16