About the heating in your home.

About the heating in your home.
About the heating in your home....
is a program le room
thermostat?
A Programmer allows you to set 'On' and'Off time periods to suit your
own lifestyle. A room thermostat works by sensing the air temperature
and switching on the heating when the air temperature falls below
the thermostat setting, switching it off once this set temperature has
been reached. A programmable room thermostat is a combination
of both. It lets you choose what times you want the heating to be on
and what temperature it should reach while it is on. It allows you to
select different temperatures in your home at different times of the
day and on different days of the week to meet your particular needs.
Accepting The Factory Pre-settings
The TPS000 S| has pre-set times already programmed in, which
often suit most people. (see table below).
Mon-Fri Sat-Sun
Event Time op Event Time | Temp°C
1 06:30 20 1 07:30 20
2 08:30 15 2 09:30 20
3 11:30 20 3 11:30 20
= 13:30 15 = 13:30 20
5 16:30 21 5 16:30 20
6 22:30 15 6 22:30 15
Note: if set up for 4 events per day, events 3 & 4 are skipped. If set up
for 2 events per day, events 2,3,4 & 5 are skipped and the events are
. A low battery symbol will flash in the LCD display
. You have 15 days in which to replace the battery before the
unit will switch off
. Remove old batteries and insert new ones, all settings
including time are maintained
Press and release the RESET button to restart the unit
NB. If the display ever goes blank during normel operation, the
batteries will need to be renewed with high quality alkaline cells. The
reset button should be pressed to restart the unit. All times, dates
and events will be retained and do not need to be reprogrammed.
Boiler Service
If your property is owned by a landlord he may have set
the boiler service timer for gas safety reasons. If this has been set
you will hear an alarm when your boiler needs servicing.
Contact your landlord immediatley to arrange the boiler service.
Failure to do so will result in your heating and hot water system
operating at areduced level.
Temporary Override Buttons
The TP5000 SI has several useful overide buttons which can be
selected without affecting the thermostat programming.
Temporary Overide Of Programmed Temperature
Press A or v until required temperature is displayed (overide will
automatically cancel at beginning of next programmed event)
Frost Protection
A constant low temperature can be selected whilst away from home
by pressing » and v together. Then use » or v to select the required
temerature. To return to automatic programming » and v together
Select Display Of Time Or Actual Room
Temperature
Press - and + together to change between settings
Reset Button
Partial reset: If the display freezes for any reason press the
RESET button. This will not reset any programme, clock or
date. It is recomended that this is done at time of installation.
User full reset: Press RESET whilst holding down the PROG
button. This resets event times and any user advanced
programme setting, but does not reset time or date.
Installer Details
Frentline
Energy 8: Environmental
TP5000 Si/TP5000 RF Si
User Instructions
Before programming the thermostat press and release the RESET button to restart CD “- Fa à
the unit. (Fig. 1) №7 № №
PROG = +
RESET
Setting the Clock and Day
The day and time are set in the factory and therefore it will not normally be necessary
to dothis onsite. Changes between summer and winter time are handled automatically
by the unit.
Accepting the Factory Pre-settings
The TP5000 Si has pre-set times already programmed in, which often suit most people
(see table below).
Mote: If set up for 4 events per day, events 3 & 4 are skipped. If set up for 2 events per
day, events 2, 3,4 & 5 are skipped and the events are re-numbered.
Mon-Fri Sat-Sun
To adjust the factory pre-settings & set your own time and temperature
programmes
For Days 1-5 (weekdays)
Press PROG (Fig. 2) until the 15 pre-settime and temperature (Event 1Days 1,2,34,5) SD
(Fig. 3).
b) Use+or- buttons (Fig. 4) to adjust the TIME (press and hold to change in 10 min
increments).
с) Use AorV buttons (Fig. 5) to adjust the TEMPERATURE.
d) Press PROG (Fig. 2) to move to next presettime é temp (Event 2) (Fig. 6).
e) Repeat steps b, c & d for programming Events 3, 4,5 86.
For Days 6-7 (weekends) SD
« Press PROG (Fig. 2) to show 1% pre-set time and temperature (Event T Days 6-7)
—
a
(Fig. 7).
= Repeat steps b, c and d above to programme time and temperature events for
the weekend.
Returning to RUN mode сэ
Press PROG (Fig. 2) - the colon in the LCD display will start to flash (Fig. 8).
Complete Shut off - Summer time
Press A and V together to enter thermostat mode. A frost protection symbal (snowflake ina
shield) will appear in the display . Press the down arrow v onde, OFF will appear in the display.
o return to automatic programming press both a and + together.
Temporary User Overrides
The TP5000 has several useful overrides which can be selected without affecting the
thermostat programming.
programmed event) (Fig. 10).
« Selection of time or actual room temperature in main LCD display - press +
and - together to change between settings (Fig. 9).
+ Temporary override of programmed temperature - press AorV until required
temperature is displayed (override will automatically cancel at beginning of next
Frost Protection - a constant low temperature can be selected whilst away from
home - press A and V together (Fig.11). Then use A orV to select the required
temperature. To return to automatic programming press Aand V together again.
maintained.
programmed.
Battery Replacement
A low battery symbol will flash in the LCD display (Fig. 12)
You have 15 days to replace the battery before the unit will switch off.
Remove old batteries and insert new ones. All settings including time are
Press and release the RESET button to restart the unit, (Fig. 1)
NB. If the display ever goes blank during normal operation, the batteries will need
to be renewed with high quality alkaline cells. The reset button should be pressed
to restart the unit. All times, dates and events will be retained and need not be re-
IMPORTANT ВЕ М | nl
To ensure that the factory pro
it Is essential that you press and hold the RESET button
programming.
Commissioning Instructions
if the thermostat and the receiver have been supplied together in a combined pack, the
units have been pairedin the factory and no commissioning is required (RX 1 only).
Step
Step 2
continucush for 3 minutes).
Step 3
(Fig. 14)
Step 4 (Fig.14)
RX 2 (if applicable)
Stat 1 - perform steps 1-3 and 5.
RX3 (if applicable)
Stat 1 - perform steps 1-3 and 5.
Step 5
TPS000-RF Si = Reset the unit by pressing the recessed reset button,
Stat 2 -perform steps 1-2 and then press PROG and CH2on RXZ.
grammes are set and the microcomputer ls operating comecty
any commissioning or
To fune the AX recever to the frequency of the thermostat signal follow steps 1-5 below.
Press and hold Vand + buttons (fig. 13) for 3 seconds (TP5000 RF Si now trans mits unique signal
RX1 - Press and hold buttons PROG and CH1 for 3 seconds until green ight lashes once
Stat 2 - perform steps 1-2 and then press PROG and СН2 оп RX3 then step 5.
Stat 3 - perform steps 1-2 and then press PROG and CH3 on RX3.
TPS0005i-RF - Press Vor A toselect temperatura - the unit will revert back to operating mode,
Service Interval Timer
to set the service interval timer.
28 days This warning is repeated each day at noon. (Fig. 15)
will enly operate for 15 minutes in each programmed hour.
as part of the boiler senice as part of the boller service.
if the property & owned by alandlord he may, for gas safety reasons, have instruc ted the installer
If set avis ual and awd ble warning will alert vou that the boiler will need servicing within the next
If thie boiler is not serviced within 28 days the daily audible warning will sound continuously and
can only be cancelled each day by pressing any button on the unit,
In addition, all ovemides and programming buttons will be disabled and the heating and hot water
As this isa gas safety feature only an installer can reset the service interval timer. This will be done
D
Selection of time
or actual room
temperature in main
LCD display
(Fig.10) Temporary
override of
programmed O
«о |
temperature
ED Frost
Protection 4 press
Danfoss Randall Ltd
Ampthill Road
Bedford, MK42 9ER
Tel: 0845 1217 400
Fax: 0845 1217 515
Email: danfossrandallédanfoss
Website: wen danfoss-randall.co uk
Frentline
Energy & Environmental
Was this manual useful for you? yes no