Upright Extractor OPERATORS MANUAL AND PARTS - Powr

Upright Extractor OPERATORS MANUAL AND PARTS - Powr
Upright Extractor
OPERATORS MANUAL AND PARTS LIST
Model PFX1350 SERIES
WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY
BEFORE OPERATING THIS EQUIPMENT.
X8607 12/2004
IMPORTANT SAFETY PRECAUTIONS
WARNING!: To reduce the risk of fire, electric shock, or injury
WARNING
To avoid electric
shock, DO NOT
expose to rain.
Store Indoors.
WARNING
To avoid fire, DO NOT
use with a flammable
or combustible liquid
to clean floor.
When using this upright extractor, basic precautions should
always be followed, including the following:
1)
DO NOT leave unit when plugged in. Unplug from outlet when not
in use and before servicing.
8)
DO NOT pick up anything that is smoking or
burning such as cigarettes, matches, or hot ashes.
2)
DO NOT allow unit to be used as a toy. Close
attention is necessary when used around or near children.
9)
DO NOT use to pick up hazardous chemicals.
3)
Use only as described in this manual. Use only
manufacturer’s recommended attachments.
4)
5)
DO NOT use with damaged cord or plug. If unit is not working
properly because it has been dropped, dropped into water, left
outdoors, or damaged in any way, contact a service center of
Powr-Flite.
10) Turn off all controls before unplugging.
11) Turn unit off immediately if foam or liquid comes from machine
exhaust. Empty & clean out recovery (dirty) tank and use defoamer
to correct the problem.
12) DO NOT use to pick up flammable or combustible liquids such as
gasoline or use in areas where they may be present.
DO NOT handle plug or appliance with wet hands.
13) DO NOT use where oxygen or anesthetics are used.
6)
7)
2
DO NOT put any objects into openings. DO NOT use with any
opening blocked: keep free of dust, lint, hair, or anything that may
reduce air flow.
14) Replace damaged or worn parts immediately with genuine original
equipment parts to maintain safety.
Keep hair, loose clothing, fingers, and all parts of body away from
openings and moving parts.
15) This unit must be connected to a properly grounded outlet only.
See grounding instruction on page 4.
GROUNDING INSTRUCTIONS
DANGER:
Improper use of the grounding plug can result in a risk of electric shock.
GROUNDING INSTRUCTIONS
This extractor must be properly grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electrical current to reduce the risk of electric shock. This
machine is equipped with 1 or 2 pigtail cords having an equipment-grounding conductor and
grounding plug. The pigtails must be inserted into an appropriate 12 gauge 3 prong extension cord.
GROUNDING METHODS
This unit is for use on a nominal 120 volt circuit and has a
grounded plug that looks like the plug illustrated in (Fig. A).
WARNING!
Improper connection of the equipment-grounding conductor can result in a risk of
electric shock. Check with a qualified electrician or service person if you are in
doubt as to whether the outlet is properly grounded. DO NOT modify the plug provided with the appliance. If it will not fit the outlet, have a proper outlet installed by
a qualified electrician.
3
General instructions for PFX1350 series Extractors
Congratulations on your purchase of a Powr-Flite extractor. You are now equipped to handle any and all commercial carpet
cleaning jobs. .
Shipping and Damage
This equipment is thoroughly inspected, tested, and packaged to provide equipment in good operating condition. It is beyond
our control after the equipment is turned over to a freight carrier. The freight carrier received and signed for the equipment in
good condition. Consequently, it is most important to protect your interest by carefully complying with the following instructions:
Please inspect your cartons for any damage (including concealed damage) that might have occurred during shipment. Any damage is the responsibility of the freight carrier and should be reported to the freight carrier immediately. It is your responsibility to
issue a claim and to receive compensation from the freight carrier for any damage done in transit. Damage of this sort is not
warranted.
Follow these easy step by step instructions to ensure proper operating performance.
1. Fill up the fresh water solution tank with tap water that is
120-135 degrees and approved carpet cleaning chemical
if you are not pre-spraying your chemical on the carpet.
2. Attach two 12 gauge extension cords (NOT INCLUDED)
(one cord for non-heated models) to each of the pigtail
cords located on the lower backside of the unit. The red
pigtail powers the heater while the black pigtail powers
the vacuum motors and pump.
3. Plug each extension cord into a separate and grounded
20 amp wall socket circuits, when this is accomplished
the green indicator light will be lit (on heated models).
4. Attach the hose system to the unit and to your carpet
wand.
5. Turn on the heater and the pump to the "on" position,
(only pump on non-heated models) when the heater is on
the orange indicator light on the switch panel will be lit.
6. With the solution line attached to the wand and the
machine, prime the pump by squeezing the trigger on the
wand releasing the water (hold wand tip over solution
tank to put water back into solution tank). This will
pump water into the heater and get any air out of the
solution line. Let the heater heat up this will take
3 to 5 minutes. *Prime pump on 400 p.s.i. models
with prime hose (included).
4
7. Turn vacuum switches to the "on" position one at at time
to begin cleaning.
8. Anyone designated to operate this equipment must,
without fail, read and thoroughly understand all
instructions and precautions prior to use.
9. Never use equipment out of doors or in the rain.
10. Never use flammable or explosive materials in
or around this equipment!!!
11. When vacuum tank is full, empty by using drain hose at
rear of machine. If a pail is used to empty the vacuum
waste tank, do not use the same pail to fill the solution
tank as this can result in putting dirt and grit into the
solution line that can plug filters, orifices, and generally
degrade the solution line system (do not reuse solution).
12. To empty solution tank, detach the wand from the end of
the vacuum hose and insert the vacuum hose into the
solution tank. Turn the vacuum switches to "on" position
and transfer solution to vacuum tank and dispose of as
outlined in #11. Clean vacuum stack filter at this time.
Maintenance
To receive reliable service from this equipment, regular daily
maintenance is a requirement. Fabric cleaning, both carpet
and upholstery, are very dirty environments for any equipment.
The following recommendations are offered.
2. Always disconnect electric cable from electrical outlet
before attempting to make any adjustments or repairs.
3. Never use this equipment as a toy.
4. Never use equipment near or around flammable or
explosive materials, fuels, or solvents.
1. Keep the equipment clean, both inside and out.
2. Lubricate brass quick disconnects and drain valves with
a quality lubricant such as WD-40.
5. Never put flammable materials, fuels, or solvents
into equipment.
6. Never lift the machine by the drain hose.
3. Flush solution systems after use with clear, clean water.
(A white vinegar solution may also be used). This will
counter-act hard water and alkaline deposits and aid
in keeping orifices clean.
4. Do not allow fluid either in solution or waste tank to sit
overnight. The unit should be emptied and cleaned daily.
5. Clean the strainer in the solution tank, the filters on the
vacuum stack in vacuum tank and all lint filters in the
inlet or vacuum tanks daily.
7. Do not allow the unit to freeze!
8. The equipment was not designed to be used outdoors
or in the rain.
9. Do not operate in standing water.
10. Wear safety equipment and clothing to protect from
extremely hot water.
11. Do not operate equipment under any unsafe condition.
6. Do not use the same receptacle (pail) to fill solution
tank that is used to remove waste from vacuum tank.
7. When the unit is not in use, leave the vacuum tank lid
open.
8. At the end of each day, run the vacuum for 3 minutes
with lid open and filter off.
Safety Precautions
These precautions are designed with the safety of the operator,
the equipment, and others in mind and must be followed at all
times to avoid serious personal harm and/or death, and damage to the unit.
1. Always use a grounded electrical outlet.
5
12. Do not operate if pigtails, hoses, etc. are cracked, frayed,
leaking, or otherwise in need of repair.
13. Common sense is a powerful force in protecting the
operator, the equipment and others from serious damage
injury and/or death.
Storage of Equipment
4. Do not use cleaning chemicals in this machine except
those recommended for steam-type extraction equipment.
The use of any chemicals with abrasive additives voids the
warranty.
5. Do not use any replacement parts except those specified
on the parts list. Performance of the machine
could be affected if substitutions are made.
1. Store extractor indoors in dry area.
2. Recovery and solution tank should be empty and clean
when the extractor is not in use.
3. Leave the recovery lid and dump valve open to air out the
recovery tank.
6. Do not use water in excess of 140° F (62° C) through
the pump system. It could damage the seals and
polyprophene casing of the diaphram pump.
7. Follow maintenance schedule strictly.
8. Failure to comply with the above warnings
instructions will void the warranty.
4. Do not store in freezing temperature.
5. A small amount of windshield washer fluid available at an
auto supply may be left in the pump and internal solution
line for protection against freezing.
Warnings
1. Do not break off or pull the grounding prong on the plug.
2. Do not attempt repair on a warrantied machine unless
instructions to perform it by an authorized shop are
obtained from the factory.
3. Do not use citrus-based (D-Limonene) cleaners in this
machine.
ONE LAST REMINDER
Read All Instructions, Warning and Cautions Before Using. These guidelines are presented for
your protection and convenience. Please read them carefully, since failure to heed these
precautions could result in discomfort or injury. When using an electrical appliance, basic
safety precautions should always be followed.
WARNING
TO AVOID FIRE, DO NOT USE WITH A FLAMMABLE OR COMBUSTIBLE
LIQUID TO CLEAN FLOOR.
6
MODEL PFX1350 SERIES CARPET EXTRACTOR PARTS
PFX1350 recovery tank assembly
ref#
order#
description
ref#
order#
description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
X9113
PX25
PX14A
PX11A
72486A
X8025
72645A
PX103G
PX103
72656A
X8295
PX33
PX31
72615A
housing, recovery tank
fitting, plastic, hose barb
dump valve gasket rubber
fitting, plastic elbow
spacer, 1.625 long, .50 od, .313 id
wheel, black, 4” x 1-1/4”
bolt, 5/16-18 x 2-1/4, hex
gasket, lid, 8”od x 6-5/8 id x 1/8” thick
lid, screw-in, 6” clear w/ black ring
hose, 1-1/2”, wire-reinforced, black
screw, black zinc
vacuum tube
float cage w/ heavy ball
coupling, pvc, 1-1/2 slip x slip
15
16
17
18
19
20
21
X9154
PX63
PX87
X8102
72387A
PX86
X9152
X9130
PAS36
PAS37
7DL005
X8235
7GR016
pipe, pvc, schedule 40, 1-1/2”, 9.5” long
coupler, plastic, 1- _” slip
rocker switch
neon light w/ lens, orang
screw, #8 x 5/8 phil ph black
indicator light, green, 250v
switch panel w/o heater
switch panel w/ heater
expansion plug drain
drain hose
clamp worm gear 1-1/2 ss
washer, _” flat, uss zinc
elbow, 1-1/4h - 1-1/4m, nylon
22
23
24
25
26
7
MODEL PFX1350 SERIES CARPET EXTRACTOR PARTS
PFX1350 base assembly
8
MODEL PFX1350 SERIES CARPET EXTRACTOR PARTS
PFX1350 base assembly
ref#
order#
description
ref#
order#
1
2
3
72620AB
72633A
X9066
PX106B
7GL002
7CM007
72634A
72635A
72640A
72623A
7CW002
72000A
72657A
72658A
72651A
70020B
1942-IE
72365A
7BF003
7CM003
72624A
72641A
PX117A
PC38
72638A
X9157
72173A
72636A
72388A
PX65
housing, base, black
axle
wheel, 12" x 1.75" non-marking,
wheel, 12" w/ 3/4" bore, all black
push nut
washer, 1/2 uss flat, 18-8 ss
bushing, 1/2" id x 3/4" od x 2-1/4" long
spacer, 1/2" id x 3/4" od x 1/4" long
gasket, vac manifold, long
cover, vacuum manifold, long
screw, #6 x 3/4 phil pan ts, type a 18-8 ss
rod, 3/16 x 5-1/2, all thread stud, 18-8 ss
screw, 10-24 x 4" long, hex head
screw, 10-24 x 5" long, hex head
spacer, vac motor, 2.375" long
gasket, vacuum motor seal
vacuum motor, 115 vac, 104 cfm, 2 stage
vacuum motor, 3 stage, 120v
nut, kep, #10-24 zinc
washer, #10 uss flat, 18-8 ss
cover, vacuum manifold, short
gasket, vac manifold, short
gauge, 0-300 psi, 2-1/2", abs
connector, double thread
pressure regulator plate
cover, pressure regulator plate
spring clip, black vinyl coated
cover plate, bottom
screw, #10 x 5/8, tap phil, ss pan head
caster, 4" black
25
26
27
28
29
30
31
32
33
34
35
36
37
38
72490A
screw, 5/16-18 x 5/8, cap screw w/ hex socket
72387A
screw, #8 x 5/8, black, tap phil, pan head
72639A
gasket, mounting pressure regulator
X8256
nut, 8-32 keps, zinc
70063B
coupler, valved 1/4, quick disconnect
7CX002
nipple, hex 1/4 mpt
72115A
washer, 5/8 x 1-3/16, bonded seal, galvanized
PC38
connector, double thread, female
72642A
gasket, vac manifold, circle
72625A
cover, vacuum manifold, circle
72627A
gasket, pump mounting
72626A
pump mounting plate
X9069
end loop, ss, w/ 2 holes, 16g
PF1750
heater unit, 1750 watts
PF1200
heater, 1200w for low flow
PF2000
heater, 2 1000 watt element (split)
PT400
pump, 200 psi w/regulator, 115v
SF814
pump, 100 psi w/by-pass, epdm valves
PT400-KIT3 pump assembly, 400 psi w/ hoses
X9022
heater mounting bracket
X8236
screw, 10-24 x 1-1/4", phil pan ms, zinc
72020A
screw, #12 x 1", self-tap, phms zinc
7BS003
screw, 1/4-20 x 1/2, phil, pan , ms 18-8 ss
X9014
hinge
PD8
strain relief, 1/2" npt
PX112
pigtail, black, 12/3 sjt x 39" long
PR112R
pigtail, red, 12/3 sjt x 39" long
X9131
cord panel
X8008N
nut, lock, 1/2" steel conduit
7BS002
screw, 8-32 x 1/2 phil, pan ms, 18-8 ss
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
PFX1350 solution tank assembly
39
40
41
42
43
44
45
46
47
48
49
50
description
ref#
order#
description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
X9112
X9014
7BS003
PX3H
PX42
PX85
PX17
PX48
72274A
PX48G
71495A
7CT002
PX88
7CM002
X9140
7CP002
7BH004
72173A
X8218
X9149
housing, solution tank
hinge
screw, phil pan ms, 18-8 ss
hose, solution, 3/8" id x 1/8" wall
clamp, 5/8 worm gear
fitting, hose male/male barb
street elbow, 45° brass, 1/4" npt
fitting, brass, bulkhead, 3/4
washer, 3/4"
gasket, fiber
pump protection filter
bolt, 5/16-18 x 1" hex tap
grommet
washer, flat #8 ss, toggle valve
tie down plate
bolt, 5/16-18 x 1/2" hex tap
screw, 10-32 x 3/8" phil pan ms
spring clip, black vinyl coated
washer, 5/16 sae flat zinc
gasket, foam strip
9
Troubleshooting Information
PROBLEM
No electrical power.
Switch is turned on.
Intermittent power to
motor(s).
Electrical Shock
ELECTRICAL SYSTEM
POSSIBLE CAUSE
SOLUTION
1. Defective power cord.
1. Replace
2. Circuit breaker off or
2. Turn circuit breaker
fuse blown.
on or replace fuse.
Unplug any equipment
using the same circuit.
1. Faulty electrical cable.
1. Repair or replace.
2. Defective switches.
2. Replace.
3. Loose terminal or dis3. Replace.
colored terminal connections.
1. Equipment not
1. Locate grounded
grounded.
outlet.
VACUUM SYSTEM
POSSIBLE CAUSE
SOLUTION
1. Drain hose open.
1. Close drain hose.
Recovery tank lid must
be closed.
2. Defective vacuum hose
2. Repair or replace.
hose. Kinks in vacuum
hose.
3. Vacuum disconnected
3. Open machine, connect
vacuum hose to
recovery tank.
Not enough vacuum
1. Damaged recovery
1. Replace
power at the machine.
tank lid.
2. Lint clogging ball 2. Remove screen.
type shutoff screen.
Clean out fibers and
accumulated dirt.
3. Vacuum hose connection 3. Check for leaks
between stand pipe and
around clamps and cuffs
vacuum motor.
(tighten). Replace damaged
hose(s).
4. Vacuum motor
4. Check air flow by
exhaust blocked.
removing hose from
machine and feel the
exhaust under the
machine. Remove
obstruction.
5. Cords not plugged into
5. Relocate one cord to a
different room.
seperate circuits
VACUUM SYSTEM
PROBLEM
POSSIBLE CAUSE
SOLUTION
Motor running and no 1. Faulty vacuum motor.
1. Replace.
vacuum at all.
No exhaust from the
2. Water shutoff closed.
2. Clean water shutoff
blowport.
screen.
Premature closing of 1. Dirty or clogged shut1. Remove and clean
ball type shutoff.
off filter screen.
screen.
2. Ball coated with
2. Remove and rinse
Ball type shutoff
detergent or other
ball with clean water.
failing to release after
recovery tank is drained. foreign material.
3. Bend screen by
2. Screen slightly out of
round.
squeezing slightly by
hand until there is an
obvious space between
ball and inside of screen.
Foam/dirty solution
1. Foam from carpet bycoming out of vacuum
passing water shutoff.
exhaust port.
2. Elbow in vacuum tank
is not positioned
correctly.
PROBLEM
Pump motor on –
no spray through jets.
PROBLEM
Vacuum motor on
Little or no vacuum
on wand head.
10
PROBLEM
Uneven spray from
jet. Spray weak or
uneven.
Leaking or stuck
solution valve.
SOLUTION SYSTEM
POSSIBLE CAUSE
SOLUTION
1. Clogged or faulty
1. Check intake on
solution control valve.
valve and remove lint
or other foreign
material.
2. Clogged or faulty
2. Depress plunger on
quick disconnect on
solution hose against
housing.
inside wall of solution
tank. If solution is flowing at this point, the
system is O.K. If no
solution flows, check the
quick disconnect for lint
and other foreign matter.
3. Punctured pump
3. Replace with
diaphragm.
diaphragm repair kit.
4. Clogged jets
4. clean jets on wand or tool.
POSSIBLE CAUSE
1. Clogged strainer in
solution tank.
2. Clogged jet.
1. Foreign material in
valve.
2. Loose brass hex nut.
3. Valve worn or seals
worn.
Pump motor
not working.
Pump pressure low
1. Use additional
defoamer.
2. The elbow should be
pointed directly at the
side wall of the tank
away from the ball type
shutoff.
1. Loose wiring
2. Defective pump
pressure switch
3. Motor burnout
1. Clogged screens on
.
2. Punctured pump
diaphragm.
3. Defective rectifier or
motor.
4. Pump not primed
Pump pressure varies. 1. Worn carbon brushes.
2. Defective pump
pressure control switch.
SOLUTION
1. Unscrew strainer
and remove lint and
any other foreign
material from screen.
2. Remove and clean.
1. Remove brass hex
plug, clean valve and
replace.
2. Reseal hex and plug.
3. Replace worn parts
with solution valve
repair kit.
1. Tighten wiring
2. Replace with new
pressure switch assembly
3. Replace pump motor
1. Unscrew strainer
strainer in solution tank
remove lint and any
other foreign material
from screen.
2. Replace with
diaphragm repair kit.
3. Replace.
4. Plug priming hose into
solution connection and place
end in solution tank. Run
pump for 4 minutes
1. Replace brushes.
2. Replace.
Series Perfect Heat
Perfect Heat Plus System
TM
WARNING! The Perfect Heat Plus System can produce very hot water that could damage some delicate
fabrics and fibers. Please ensure the surface being cleaned will not be damaged by hot water up to 200 degreEs
Fahrenheit.
TM
This machine is equiped with the Perfect Heat Plus System for heating the cleaning solution. This system uses a combination of the patent pending Perfect Heat coils and an inline electrical heater.
TM
TM
Operation:
1. Follow operating instructions steps for filling the machine with water and cleaning solution.
2. Turn on electrical heater, switch is located on panel.
3. Pre-heat machine for 5-10 minutes before use.
NOTE: There is a valve in the upper compartment that either sends the water through the heating components, or
bypasses them. The machine is preset in the “HOT” position. To clean with cold water, turn the valve to “COLD” or UP
position. This should be done prior to filling the tank with water. For general cleaning, it is recommended leaving the
valve in the “HOT” or down position and cleaning with hot water.
switch panel
valve
3101 Wichita Court ■ Fort Worth, TX 76140 ■ 800.880-2913 ■ www.Powr-Flite.com
XXXXX 06/2005
Ref #
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
Part #
72620AB
72633A
X9066+
7GL002
7CM007
72635A
72640A
72623A
7CW002
72000A
72658A
72605A
70020B
72611A
7BF003
7CM003
72624A
72641A
X9069+
72638A
72173A
72636A
72388A
PX65+
7DT001
72387A
72661A
72662A
PX6+
7CX002
X8239+
PC38+
72642A
72625A
72643A
72639A
71644A
PF1750-2+
72020A
7BS003
X9014+
PD8+
PX112+
PX112R+
X9131+
X8008N+
X9177+
72665A
X8256+
7BS002
7GF033
X8848+
7EW001
X8235+
71521A
7DL008
70079C
X9098+
X9178+
X8542+
PC66+
71130A
70101A
72713B
7AT003
SW158+
X8244+
7AV001
72726A
PX212+
7DL003
Description
Housing, Base, Black
Axle, 23.375” Long
Wheel, 12" x 1.75" Non-Marking, Gray Tire on Black Wheel
Push Nut
Washer, 1/2 USS Flat, 18-8 SS
Spacer, 1/2" ID x 3/4" OD x 1/4" Long
Gasket, Vac Manifold, Long
Cover, Vacuum Manifold, Long
Screw, #6 x 3/4 Phil Pan TS, Type A 18-8 SS
Rod, 3/16 x 5-1/2, All Thread Stud, 18-8 SS
Screw, 10-24 x 5" Long, Rnd Slot, Zinc, Fully Threaded
Spacer, 1/8” Schedule 80 PVC, 3.5" Long
Gasket, Vacuum Motor Seal
Vacuum Motor, 3-Stage, 230V, 5.7IN
Nut, Kep, #10-24 Zinc
Washer, #10 USS Flat, 18-8 SS
Cover, Vacuum Manifold, Short
Gasket, Vac Manifold, Short
End Loop, SS, w/ 2 holes, 16G
Pressure Regulator Plate
Spring Clip, Black Vinyl Coated
Cover Plate, Bottom
Screw, #10 x 5/8, Tap Phil, SS Pan Head
Caster, 4" Black
Bolt, 5/16-18 x 5/8, Hex Tap Zinc
Screw, #8 x 5/8, Black, Tap Phil, Pan Head
Wand Holder
Screw, #10 , Phil Flat SM, Black, Undercut Head
1/4 x 1/4 Female Quick Disconnect, Brass
Nipple, Hex 1/4 MPT
Washer, USS Flat Zinc
Connector, Double Thread, Female, 1/4" to 1/4" Coupling
Gasket, Vac Manifold, Circle
Cover, Vacuum Manifold, Circle
Pump Assembly, 500 PSI
Gasket, Mounting Pressure Regulator
Screw, #10 x 1”, Phil Pan, TS, Type A 18-8 SS
Heater Unit, 220V
Screw, #12 x 1”, Self-Tap, PHMS, Zinc
Screw, 1/4-20 x 1/2, Phil, Pan , MS 18-8 SS
Hinge
Strain Relief, 1/2" NPT
Pigtail, Black, 12/3 SJT x 39" Long
Pigtail, Red, 12/3 SJT x 39" Long
Cord Panel
Nut, Lock, 1/2" Steel Conduit
Screw, Phil Pan, Ext Tooth Washer, Fully Threaded
Insert, Tee Nut, ?-20 Thread, ? High, .305 Barrel Diameter
Nut, 8-32 Keps, Zinc
Screw, 8-32 x 1/2 Phil, Pan MS, 18-8 SS
Pad, Motor Mount
Jacknut, 1/4-20, Steel, #8 LJN
Screw, 1/4-20 x 3/4", Phil, Pan, MS SS
Washer, 1/4 Flat, USS, Zinc
Tee, Barb, 1/2" x 1/2" x 1/2"
Clamp, 1/2" Worm Gear, SS, Hex Slot
Hose, 1/2" Wire Reinforced
Screw, #10 x 1”, A point, PH pan head
Foam, Cord Panel
Hose, Solution, 1/4" ID, 400 PSI
Fitting, Brass, 1/8 NPTM x 1/4 Hose Barb
Coupler, QD, 1/8 M
Nipple, QD, 1/8 F, Brass
Heater coil, 3-Stage Vacuum
Barb, Hose, 1/4 H – ? M
Cable Clamp
Screw, 10-24 x 2”, Phil, Pan MS, Zinc
Tee Union, 1/4 NPT
Valve, 3-Way
Fitting, Brass, 90° Elbow, 1/4 NPTM x 1/4 Hose Barb
Clamp, Hose, 1/4"
Qty
1
1
2
2
6
2
2
2
26
1
3
4
2
2
18
6
1
1
1
1
1
1
6
2
8
8
1
3
1
2
1
1
1
1
1
2
1
1
4
4
2
2
1
1
1
2
2
2
4
4
2
4
4
4
1
5
42”
2
1
70”
5
2
2
1
2
2
2
1
1
1
7
WARRANTY
The manufacturer warrants to the original purchaser that products manufactured are free from defects of
workmanship and material, provided such goods are installed, operated and maintained in accordance with
written manuals or other instructions for a period of 5 years from date of purchase on housings and frame, 3
years on heater, 1 year on pump, vac motor, and parts and workmanship. In case you as our customer, meet
any trouble with your machine, contact your Powr-Flite representative who will be happy to be of service to
you and will take care of the warranty settlement.
NOTE: Alterations and changes made to the machine without written approval of the
manufacturer and use of unapproved spare parts will not be covered by warranty.
A Tacony Company
3101 Wichita Court • Ft. Worth, TX 76140-1710
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising