MX6 iBrid
Multi-Gas Monitor
Operation Guide
Part Number:
Revision:
Release Date:
17130279-1
6
03.01.2013
Ex-Ox-Tox Gasdetectie
Westerdreef 5V
2152 CS Nieuw-Vennep
Telefoon: 0252 620885
E-mail: info@exoxtox.nl
Website: www.exoxtox.nl
™
MX6 iBrid™ Multi-Gas Monitor
Table of Contents
CERTIFICATIONS .................................................................................................................................................... 3 WARNINGS AND CAUTIONARY STATEMENTS............................................................................................... 3 KEY FEATURES ........................................................................................................................................................ 8 QUICK START MENU FLOWCHARTS .............................................................................................................. 10 CHARGING THE BATTERY ................................................................................................................................. 11 MENU OPERATION BASICS ................................................................................................................................ 13 POWER UP AND SHUT DOWN ............................................................................................................................ 14 NORMAL OPERATION MODE............................................................................................................................. 14 VIEW MENU OPTIONS .......................................................................................................................................... 16 CONFIGURATION MENUS ................................................................................................................................... 17 CALIBRATION POLICY ........................................................................................................................................ 18 ZERO ALL OPTION ................................................................................................................................................ 19 CALIBRATE OPTION ............................................................................................................................................. 19 BUMP TEST OPTION ............................................................................................................................................. 21 DATALOG MENU OPTIONS ................................................................................................................................. 22 CONFIGURATION MENUS ................................................................................................................................... 23 SENSOR SPECIFICATIONS AND CORRELATION FACTORS ...................................................................... 25 WARRANTY ............................................................................................................................................................. 28 2
INDUSTRIAL SCIENTIFIC
MX6 iBrid Multi-Gas Monitor
Operation Guide
CERTIFICATIONS
Directive/Code
Certification Marking
Standard
ATEX1
Ex ia IIC T4 Ga / Ex ia I Ma; IP65 (IP64 pump EN 60079-0: 2009
version)
EN 60079-1: 2007
Equipment Group and Category: II 1G/ I M1 (I
EN 60079-11: 2007
M2 w/IR sensor)
EN 60079-26: 2007
EN 50303: 2000
EN 50271: 2001
EN 60079-29-1: 2007
EN 50104/A1: 2004
IECEx2
Ex ia IIC T4 Ga T4
IEC 60079-0: 2007
Ex ia I (Ex ia d I w/IR sensor)
IEC 60079-1: 26:2006
IEC 60079-11: 1999
UL3
Class I, Group A B C D T4
UL 913 7th Ed.
Class II, Group F G
UL 60079-0 5th Ed.
Class I, Zone 0, AEx ia IIC T4
UL 60079-11 5th Ed.
2
The IECEx examination certificate is IECEx UL07.0004X with marking code Ex ia IIC T4 Ga for an ambient
temperature range of -20°C to 40°C, with the alkaline battery P/N 17131046-3 or -20°C to 55°C with the li-ion
battery pack, P/Ns 17131038-1, and 17131038-2.
1
The MX6 multi-gas monitor complies with relevant provisions of European ATEX directive 94/9/EC and EMC
directive 2004/108/EC.
1
The EC type examination certificate is DEMKO 07 ATEX 0626395X; for equipment group and category II 1G;
with marking code Ex ia IIC T4 Ga for an ambient temperature range of -20°C to 40°C, with the alkaline battery
pack P/N 17131046-3 or -20°C to 55°C with the li-ion battery pack, P/Ns 17131038-1, and 17131038-2.
1
The EC type examination certificate is INERIS 08 ATEX 0026X; for equipment group and category I M1 /M2 with
marking code Ex ia d I for an ambient temperature range of -20°C to 40°C, with the alkaline battery pack P/N
17131046-3 or -20°C to 55°C with the li-ion battery pack, P/Ns 17131038-1, and 17131038-2.
1
The EC type examination certificate is INERIS 10 ATEX 0027X; for equipment group and category II 2 G with
marking code EN 60079-29-1, and EN 50104.
1 and 2
The MX6 multi-gas monitor is constructed with reference to published standards of directive 72/23/EEC, to
eliminate electrical risks and fulfill 1.2.7 of ANNEX II of directive 94/9/EC.
3
The MX6 is UL classified only as to intrinsic safety for use in Class I, Division 1, Groups A B C D; T4 and Class
II, Groups F, and G and Class I, Zone 0, AEx ia IIC T4 classified locations with the li-ion battery pack P/Ns
17131038-1, and 17131038-2 for T ambient ≤ 55ºC or alkaline battery pack P/N 17131046-3 for T ambient ≤ 40ºC.
WARNINGS AND CAUTIONARY STATEMENTS
IMPORTANT: Failure to perform certain procedures or note certain conditions may impair the
performance of this product. For maximum safety and optimal performance, please read and
follow the procedures and conditions listed below.
INDUSTRIAL SCIENTIFIC
3
Operation Guide
MX6 iBrid™ Multi-Gas Monitor
IMPORTANT: Read and understand this manual before operating.
IMPORTANT: The instrument must be charged before its first use.
IMPORTANT: Be sure to turn off the instrument before (1) servicing the unit or (2)
replacing the battery.
IMPORTANT: Battery contacts are exposed on battery packs when they are removed
from the instrument. Do not touch the battery contacts and do not stack battery packs on
top of each other.
Warning: Explosion hazard. Only replace batteries in non-hazardous locations. Alkaline
battery pack is only approved for use with Duracell MN 1500 or Rayovac LR6 batteries.
Do not mix batteries from different manufacturers. Replace all batteries at the same time.
Prior to each day’s use, a bump test should be performed. If the instrument does not pass
the bump test, a full calibration is recommended.
Oxygen deficient atmospheres may cause combustible gas readings to be lower than
actual concentrations.
Oxygen enriched atmospheres may cause combustible gas readings to be higher than
actual concentrations.
Verify the calibration of the combustible gas sensor after any incident where the
combustible gas content has caused the instrument to display an over-range condition.
Silicone compound vapors or other known contaminants may affect the combustible gas
sensor and cause readings of combustible gas to be lower than actual gas concentrations.
If the instrument has been used in an area where silicone vapors were present, always
calibrate the instrument before next use to ensure accurate measurements.
Sensor openings and water barriers must be kept clean. Obstruction of the sensor
openings and/or contamination of the water barriers may cause readings to be lower than
actual gas concentrations.
Sudden changes in atmospheric pressure may cause temporary fluctuations in the oxygen
reading.
Charge battery, service unit, and use its communication port only in non-hazardous
locations. Not for use in oxygen-enriched atmospheres.
WARNING: Substitution of components may impair intrinsic safety and may cause an
unsafe condition.
AVERTISSEMENT: La substitution de composants peut compomettre la securite
intinseque.
CAUTION: For safety reasons, this equipment must be operated and serviced by
qualified personnel only. Read and understand the instruction manual completely before
operating or servicing.
ATTENTION: Pour des raisons de sécurité, cet équipment doit étre utilesé entretenu et
réparé uniquement par un personnel qualifié. Étudier le manuel d'instructions en entier
avant d'utiliser, d'entretenir ou de réparer l'équipement.
4
INDUSTRIAL SCIENTIFIC
MX6 iBrid™ Multi-Gas Monitor
Operation Guide
CAUTION: High off-scale readings may indicate explosive concentration.
ATTENTION: Des lectrures supérieures a l'échelle peuvent indiquer des concetratoins
explosives.
CAUTION: Any rapid up-scale reading followed by a declining or erratic reading may
indicate a gas concentration beyond the upper scale limit which may be hazardous.
Canadian standards association (CSA) has assessed only the combustible gas detection
portion of this instrument for performance according to CSA standard C22.2 No. 152.
CSA No. 152 certification applies when the instrument is calibrated to 50% LEL CH4,
and for a temperature range of 0°C to 40°C.
CAUTION: Before each day’s usage, sensitivity must be tested on a known
concentration of pentane or methane equivalent to 25%-50% of full scale concentration.
Accuracy must be within -0% to +20% of actual concentration. Accuracy may be
corrected by referring to the zero/calibration section of the instruction manual.
The MX6 multi-gas monitor is certified as intrinsically safe for Zone 1 Classified Areas
within an ambient temperature range of -20°C to 40°C, with the alkaline battery pack and
-20°C to 55°C with the li-ion battery pack.
NOTE: The MX6 is CSA certified according to the Canadian Electrical Code for use
in Class I, Division 1 Hazardous Locations within an ambient temperature range of 40°C to 40°C for the alkaline battery pack and -40°C to 55°C for the li-ion battery
pack.
The MX6 multi-gas monitor is constructed with reference to published standards of
directive 2006/95/EC, to eliminate electrical risks and fulfill 1.2.7 of ANNEX II of
directive 94/9/EC.
WARNING: The use of leather cases can produce inaccurate readings with diffusion
(non-aspirated) gas detection instruments for specific monitoring applications. Leather
cases should be used ONLY as carrying cases, and NOT for continuous monitoring, with
diffusion instruments configured to measure gases other than O2, CO, CO2, H2S, and
combustible gases (LEL/CH4).
Industrial Scientific recommends the “2 & 2 Sampling Rule” when sampling with a
motorized pump and tubing, one should allow for 2 minutes plus 2 seconds per foot of
tubing used, prior to noting the monitor readings. This allows time for the gas to reach
the instrument and for the sensors to adequately react to any gases present. ISC
recommends that clear urethane tubing, part number 17065970, be used with the pumped
versions of the MX6 iBrid when sampling for the following gases: Ammonia (NH3),
Chlorine (Cl2), Chlorine Dioxide (ClO2), Hydrogen Chloride (HCl), Hydrogen Cyanide
(HCN), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Phosphine (PH3), Sulfur Dioxide
(SO2), or Photo Ionization Detectors (PIDs) used to detect volatile organic compounds
(VOCs).
Contact your service representative immediately if you suspect that the MX6 monitor is
working abnormally.
Specifications subject to change.
  
INDUSTRIAL SCIENTIFIC
1-5
MX6 iBrid Multi-Gas Monitor
Operation Guide
The following instructions pertain to the use of the MX6 in conjunction with MSHA
approval.
Conditions of Use:
MSHA approved for use with the following battery packs only:
(A) Replaceable alkaline battery pack, P/N 1713-1046-6, consisting of three each of
either of the following 1.5 V battery types: Duracell MN 1500 or Rayovac LR6.
 Do not mix batteries from different manufacturers.
 Replace all batteries at the same time.

The individual alkaline batteries may be replaced in a gassy area. Do not allow dust to
enter the unit when replacing individual batteries.

The battery pack must be replaced in fresh air only.
(B) Rechargeable lithium-ion battery pack P/N 1713-1038-4, or -5, containing two or
three 3.6V, 1.8 amp-hour Lithium Batteries.
• The lithium-ion cells are not user-replaceable.
• The lithium-ion pack must be charged in fresh air only.
CAUTION: For compliance determinations required by 30 CFR 75, Subpart D, the monitor
must display "CH4" and “%VOL” during the monitor's start-up sequence.
CAUTION: The Model MX6 iBrid Multi-Gas Monitor must be configured to include a
catalytic sensor, Model 4L-LEL, P/N 1710-5081, (CH4, 0-5% v/v).
CAUTION: The IR (infrared) methane sensor reading is not to be used for methane
concentrations below 5% in air.
CAUTION: The Model MX6 iBrid Multi-Gas Monitor must be calibrated according to the
procedure specified in the instruction manual.
CAUTION: In applications requiring MSHA certification, the IR sensor for detecting up to
100% v/v methane-in-air the sensor must be calibrated manually; the DS2 docking station cannot
be used to calibrate the IR sensor. The recommended calibration gas for IR methane sensor
calibration is 99% volume methane.
CAUTION: When calibrated using methane concentrations less than 5% of
volume, reading accuracy of the infrared methane sensor may not be
guaranteed to be better than +/-20%.
INDUSTRIAL SCIENTIFIC
6
MX6 iBrid™ Multi-Gas Monitor
Operation Guide
Hardware Overview
The MX6 multi-gas monitor is Industrial Scientific Corporation’s next-generation handheld,
“dockable,” multiple gas monitoring instrument. It includes up to five temperature-compensated
sensors to monitor up to six ambient gases across the full temperature range of the instrument.
Sensor Openings
(Filters Beneath)
Sensor Filter
(Beneath
Sensor
Openings)
Visual Alarm
(Beneath Sensor
Openings)
Chassis
LCD
Wrist Strap
Connector
(Not Shown)
5-Way
Navigation
Button
Battery Charging
Contacts (Not Shown)
IR Communications
Port (Not Shown)
Up
Left
Enter
Right
Down
NOTE: The backlight of the LCD is enabled for 7 seconds each time a button is pressed. Any
additional button press during the 7 seconds reset the timer for an additional 7 seconds.
INDUSTRIAL SCIENTIFIC
7
Operation Guide
MX6 iBrid™ Multi-Gas Monitor
Key Features
Audio
Indicator
Used for alarming, warnings, and the optional confidence indicator. There are
two levels of audio gas alarms based on the frequency of the beeps and the
length of delay between beeps.
Low-level (level-1)
High-level (level-2)
Low frequency beeps with a long delay
High frequency with short delay
For all sensors but oxygen, if the gas reading is above the high alarm level, the
instrument sustains the high alarm until the gas reading is below the high alarm
level, then the instrument switches to the low alarm until the gas reading is
below the low alarm level. For the oxygen sensor, a high alarm only is
indicated for both oxygen enrichment and depletion.
Vibrating
Alarm
Optional pulsing alarm that is used for limit alarms and as a confidence
indicator.
Visual Alarm
The instrument has alarm LEDs located beneath the opaque sensor array at the
top of the unit. There are two levels of visual alarms based on the length of
delay between the LED flashes.
Low-level (level-1)
High-level (level-2)
LEDs are pulsed with a long delay
LEDs are pulsed with a short delay
The LCD backlight flashes as part of all alarm sequences, except for the
battery low condition. The visual alarm is also used as the confidence
indicator which, when enabled, blinks the LEDs once every 30 seconds.
Infrared (I/R)
Port
An optical media interface (per IrDA physical layer specification) is located on
the bottom of the instrument and is used for infrared (I/R) data transmissions at
speeds of 115200 bytes/second.
Clip/Connector
Located on the back of the MX6 for hands-free gas monitoring. A wrist strap
is also provided to protect against drops during operation.
Cradles
Three different cradles are available for use with the MX6 multi-gas monitor.



8
Charger
Datalink
Charger/Datalink
Charge the internal batteries
Download data (e.g., events) to a host computer
Combination of both.
INDUSTRIAL SCIENTIFIC
MX6 iBrid™ Multi-Gas Monitor
Operation Guide
Color LCD
The STN color graphic liquid crystal display (LCD) uses a 256-color palette
(including a gray scale) and graphics for displaying information.
Menu-Driven
User
Interface
The user interface is menu-driven and contains the LCD, Navigation Button,
Audio Indicator, Vibrating Alarm, and Visual Alarm. It consists of two different
main menus. The background color of the LCD identifies the current menu.


Normal Operation Menu
Configuration Menu
White background on LCD
Yellow background on LCD.
During Normal Operation Mode, the menu bar is hidden, but can be displayed by
pressing the center [ENTER] navigation button. The menu bar has a five-second
time out. If no button is pressed within five seconds of the menu being
activated, it is deactivated.
Security
Access to the Configuration Menu can be protected using a security password.
When activated, this password must be entered in order to access and change the
parameters within the Configuration Menu.
Alarm Events Fifteen alarm events for the instrument are recorded into a FIFO queue in nonvolatile memory and are time stamped. An event is recorded any time that the
instrument goes into alarm. Event information (which can be downloaded from
the instrument) includes instrument serial number, sensor type, sensor serial
number, gas type, peak exposure level, alarm duration in minutes and seconds,
and date and time that alarm occurred.
Error Events
Fifteen error events for the instrument are recorded into a FIFO queue in nonvolatile memory and are time stamped. An error event is recorded any time that
a fault occurs (including pump faults and fault events during the self-test). The
information stored for each event includes instrument serial number, fault that
occurred, fault error code, date and time stamp, and any pertinent data (i.e.,
pump current reading).
Datalog
Datalogging is a feature that allows a variety of system parameters to be
recorded at regular intervals (and saved internally) for retrieval (and viewing) at
a later date. The datalog feature saves the following information:






Gas Type
Time of Day
Temperature
Alarm Conditions Flagged
STEL
Snapshot Enabled/Disabled






Gas Reading
Date
Battery Level
User ID
Site ID
TWA
NOTE: Data saved for one year can be downloaded within 15 minutes.
NOTE: Data is saved in case of power loss.
INDUSTRIAL SCIENTIFIC
9
Operation Guide
MX6 iBrid™ Multi-Gas Monitor
Quick Start Menu Flowcharts
10
INDUSTRIAL SCIENTIFIC
MX6 iBrid™ Multi-Gas Monitor
Operation Guide
Charging the Battery
The MX6 multi-gas instrument is powered using an internal alkaline or Lithium-ion (Li-ion)
rechargeable battery. The Li-ion battery is partially charged before it leaves the factory, but
must be fully recharged prior to use. To charge the battery, follow the steps listed below.
1.
2.
3.
4.
Insert the power cord of the charging cradle into an appropriate wall outlet.
Place the instrument in a Charger or Charger/DataLink cradle.
Note that the LCD on the MX6 shows that the battery is charging.
Wait 8 hours for the MX6 to be fully charged.
INDUSTRIAL SCIENTIFIC
11
Operation Guide
MX6 iBrid™ Multi-Gas Monitor
Under the main menu [View] option, there is a [Battery] menu option. The menu provides a link
to the Battery Status screen.
The Battery Status screen shows approximately how much run-time is left on the instrument.
The instrument polls the battery manager every second to get a battery voltage reading. The user
is able to cycle through the main battery and any attached modules to get the battery status.
NOTE: The Battery Status screen is shown for 15 seconds, after which, the instrument returns
to the Normal Readings screen.
The Battery icon on the NRS visually reflects the current status of the battery life as well.
Depending on the installed LCD, one of two different icons may appear for each charge level.
Charge
remaining
>100%
Icon (color)
Icon (color)
(blue)
(blue)
>75%
(blue)
(blue)
>50%
(blue)
(blue)
>25%
(blue)
(yellow)
>5%
(yellow)
(red)
NOTE: If the battery life remaining is less than
one hour, the battery icon also flashes on the
display and has an audible battery low alarm. If the
runtime is less than 10 minutes, instrument alerts
the user of impending shutdown by showing “Low
Battery” on the lower central part of the display,
where the response factor would be. If there is a
response factor there, the “Low Battery” is
displayed instead of the response factor.
12
INDUSTRIAL SCIENTIFIC
MX6 iBrid™ Multi-Gas Monitor
Operation Guide
Menu Operation Basics
The actions that are initiated by pressing the five-way navigation button may vary significantly
based on (1) the user’s location within the menu structure, and on (2) a particular action item of
interest (of many) on one individual screen. Focus refers to a way of identifying that single item
(from possibly several items) on the LCD screen.
There are several types of “indicators” that may be present on any given LCD screen within the
menu structure of the MX6 instrument. These indicators include:





single function buttons (e.g., OK button)
radio buttons (e.g., select user profile)
check box buttons (e.g., an enable/disable check box)
text box windows (e.g., user-supplied site name)
combo box windows (combinations of these).
Typically, the [LEFT] and [RIGHT] navigation buttons are used to change the current focus and
cycle through those items on the screen that allow some form of user intervention. The item that
currently has the focus is usually denoted with highlighting or a border.
The actions of other buttons are typically dependent on the type of item that has focus. For
example, when a checkbox control has focus, the center [ENTER] navigation button toggles the
check on and off. When a group of radio button controls has focus, the [UP] and [DOWN]
navigation buttons are used to switch focus between the controls and the center [ENTER]
navigation button is used to complete the selection.
When a text box is displayed, the user changes the value of each character one at a time. Once
the focus is on the text box, pressing [ENTER] allows changes to be made to the character values
in the text box. The user changes the character value of the field by using the [UP] and [DOWN]
navigation buttons. The list of available characters varies by text box. The user advances to the
next character using the [RIGHT] navigation button. The user can backspace to the previous
character using the [LEFT] navigation button.
To get the focus on the combo box, the center [ENTER] navigation button must be pressed. If
the user presses the [UP] or [DOWN] navigation buttons when the focus is on the combo box,
the user can scroll through the list of entries. To select one, the user must press the [ENTER]
navigation button once the focus is on the desired entry. Pressing the [RIGHT] or [LEFT] key
removes the focus from the combo box.
If the backlight is off, the first button press only turns on the backlight. If the backlight is on, the
first button press triggers the action.
INDUSTRIAL SCIENTIFIC
13
Operation Guide
MX6 iBrid™ Multi-Gas Monitor
Power Up and Shut Down
Two key operation basics are powering up the
instrument and shutting it down. To power up the
MX6 instrument, locate, press and hold the center
[ENTER] navigation button for at least 3 seconds.
After power up, a series of startup screens are
displayed on the LCD. Optional startup screens may
be displayed depending on your configuration.
Up
Left
Enter
Right
Down
If the unit detects a pump, it requires the operator-assisted completion of a pump check, a built-in
safety measure to ensure the pump is working correctly. The instrument operator is prompted
through the process with the following display-screen sequence.
No action necessary.
Place a finger over the
pump inlet to block the
flow of air.
Remove the finger from
the inlet and press .
No action necessary. After a
brief waiting period, the
operation screen is activated.
To shut down the instrument, hold the center [ENTER] navigation button for more then two
seconds. A confirmation screen is displayed to provide verification of the shut down.
Normal Operation Mode
After the optional Startup Self Test is
Installed
completed, the instrument displays the
Sensor(s)
Normal Operation Mode.
The
Normal Readings screen is the default
screen displayed while the instrument
is in Normal Operation Mode. Other
options include View Menu Options,
Sensor Menu Options, and Datalog
Menu Options. Configuration menus Battery
and options are accessed through the Status
Configuration option of the View
Icon
Menu.
Up to six sensors may be installed in
the instrument. As a result, the screen
layout of sensor information varies
based on the number of sensors that
are actually installed.
14
Datalog
Status Icon
INDUSTRIAL SCIENTIFIC
Current
Reading(s)
Unit(s) of
Measure
Current
Time
Response/Correlation
Factor (for PID/LEL)
MX6 iBrid™ Multi-Gas Monitor
Display Component
Sensor Name
Sensor Reading
Sensor Units
Operation Guide
Attribute
Normal Mode
Alarm Mode
Color
Black
Black
State
Solid
Solid
Color
Black
Red
State
Solid
Solid
Color
Black
Black
State
Solid
Solid
NOTE: For over range conditions, a blinking “OR” is displayed in red as the sensor value. If
the alarm is a STEL or TWA, the word “STEL” or “TWA” are shown to indicate the
corresponding alarm.
Sensor names are displayed as solid black text during normal operation, and blinking black text
during alarm conditions. The sensor readings are displayed as solid black numerals during
normal operation, and solid red numerals during alarm conditions. Units (e.g., % Vol, ppm,
%LEL, etc.) are displayed as black text beneath the sensor readings. Below is a summary of
navigation instructions available for the Normal Readings Screen (NRS).
Destination
Description
Menu Display
Press and release the center [ENTER] navigation button. Use the [UP],
[DOWN], [LEFT] and [RIGHT] navigation buttons to navigate the menus.
Once activated, the menu is deactivated if no buttons are pressed within five
seconds.
Shutdown
Hold the center [ENTER] navigation button for more then two seconds.
Battery Status
From the [VIEW] option, select [BATTERY] to view the battery status.
Datalog
From the [DATA] menu option, select [VIEW DATA] then [MEMORY
Memory Status STATUS] to display the Datalog Memory Status screen.
Sensor
Selection
When there is more the one sensor, it is possible to view the installed sensors
one at a time. Pressing either the [LEFT] or [RIGHT] navigation button
causes the Sensor Selection (SS) menu to be displayed along the right side of
the screen.
The Sensor Selection menu lists the currently installed sensor and the
selection “All” (the default). Navigate the Sensor Selection list using the
[UP] and [DOWN] navigation buttons (with wrap-around).
When a sensor is selected, press the center [ENTER] navigation button to
display the selected sensor in Single Sensor Layout mode. The SS menu
remains on the left. If the “All” list item is selected and the center [ENTER]
navigation button is pressed, all currently installed sensors are displayed and
the SS menu is deactivated. When the SS menu is activated and a sensor
other than the one selected goes into alarm, then that sensor alarm type (in
red) is cycled with the sensor name.
INDUSTRIAL SCIENTIFIC
15
Operation Guide
MX6 iBrid™ Multi-Gas Monitor
View Menu Options
16
INDUSTRIAL SCIENTIFIC
MX6 iBrid™ Multi-Gas Monitor
Operation Guide
Configuration Menus
Under the main menu [View] option, there is a
[Configure] menu option. This menu provides access
to the Configuration screens of the instrument. The
user must enter a password to get to the Configuration
Menus (if a password has been set). If the password is
still the factory default of nothing, no password
protection is set. In this case, the instrument directly
enters Configuration mode.
If the password is anything other than the factory
default value, the [Password] screen is displayed. The
[Password] screen is used to enter a password for
verification, as well as changing the current password.
This password can and should be different than the user
profile passwords.
NOTE: Passwords are a minimum of three characters
and a maximum of 10.
NOTE: If the user uses any navigation buttons while
this screen is displayed, the screen time-out timer is
suspended. The screen time-out timer suspends for 30
seconds after the last navigation button is pressed.
NOTE: If the user doesn’t remember the password, entering “412” as the password and pressing
the [LEFT] and [RIGHT] navigation buttons simultaneously resets the password to nothing.
The initial Configuration Screen consists of several
pieces of information:



Config, Sensor, and Data Menus
Exit button
Save Profile button.
NOTE: All screens under the Configuration menu
have a yellow background.
The Exit Button and the [] exits Configuration mode and returns to the Normal Readings
screen. Changes to the configuration are saved while the instrument remains on, but do not
affect the current profile.
The Save Profile Button exits the Config mode and returns to the Normal Readings screen.
Changes to the configuration are saved to the current profile.
INDUSTRIAL SCIENTIFIC
17
Operation Guide
MX6 iBrid™ Multi-Gas Monitor
NOTE: To reset the password to nothing, the user must enter “412” as the password, and then
press and hold the [LEFT] and [RIGHT] navigation buttons simultaneously.
NOTE: If a time for a configuration screen to remain showing is not specified in this document,
it is 90 seconds. After 90 seconds the instrument returns to the main Configuration screen. After
5 minutes of being on the main configuration screen, the instrument returns to the NRS.
NOTE: If the instrument is still reading gas while in configuration mode, and there is an alarm,
the instrument returns to the normal readings screen, but then allows the user to go back into the
Configuration menu.
The Configuration, Sensor, and Datalog menus are explained in their own chapters later in this
manual.
Calibration Policy
Gas detection instruments are potentially life-saving devices. Recognizing this fact, Industrial
Scientific Corporation recommends that a functional (“bump”) test be performed on every
instrument prior to each day’s use. A functional test is defined as a brief exposure of the monitor
to a concentration of gas(es) in excess of the lowest alarm setpoint for each sensor for the
purpose of verifying sensor and alarm operation and is not intended to be a measure of the
accuracy of the instrument. If an instrument fails to operate properly following any functional
“bump” test, full instrument calibration should be performed prior to use. If conditions do not
permit daily testing, bump tests may be done less frequently based on instrument use, exposure
to gas, and environmental conditions. The frequency of testing is best determined by company
policy or local regulatory agencies.
Industrial Scientific further recommends that a full instrument calibration be performed using a
certified concentration(s) of Industrial Scientific branded calibration gas(es) monthly to ensure
maximum accuracy. Use of calibration gases from manufacturers other than Industrial Scientific
may void product warranties and limit liability claims against the manufacturer.
These recommendations are based on safe work procedures, industry best practices and
regulatory standards to ensure worker safety. Industrial Scientific is not responsible for setting
safety practices and policies.
Prior to each day’s use, a bump test should be performed. If the instrument does not pass
the bump test, a full calibration is recommended.
18
INDUSTRIAL SCIENTIFIC
MX6 iBrid™ Multi-Gas Monitor
Operation Guide
Zero All Option
Under the main menu [Sensor] option, there is a [Zero All]
menu option.
If [Zero All] is selected, the MX6 displays the verification
question. At this time, the focus is on the OK button.

If Cancel is selected, the user is returned to the NRS and
the zeroing is skipped.

If the OK button is selected, the zeroing of the sensors
starts.
If there is a CO2 sensor present in the instrument, it is zeroed
last. Zero air must be applied to zero a CO2 sensor. The
instrument prompts the user to apply zero air. The focus is on
the OK button. If the user selects the OK button, the CO2
sensor starts zeroing.
By pressing the [LEFT] or [RIGHT] key, the focus moves
from the OK button to the Cancel button and back again. If the
user selects Cancel, the CO2 sensor is not zeroed.
If there is an oxygen sensor installed in the instrument, it is
calibrated during the zeroing operation.
When the zero is finished, the results screen is displayed.
Selecting OK, by pressing [ENTER] when the focus is on the
OK button, returns the instrument to the NRS. If OK is not
selected, the instrument asks if the user wants to calibrate after
a 15 second time-out. The calibration confirmation screen will
have focus on the Cancel button.
Calibrate Option
The instrument alarms are deactivated during the calibration to save battery life. If the
[Calibrate] option is selected, the instrument displays the confirmation screen shown below. If
Cancel is selected, the user is returned to the NRS.
INDUSTRIAL SCIENTIFIC
19
Operation Guide
MX6 iBrid™ Multi-Gas Monitor
If the user selects OK, all the installed sensors are zeroed first (following the Zero All steps) and
then calibrated. After the zero, the results are shown, for 5 seconds and then the calibration of
the first sensor begins.
The screen to alert the user to connect gas to the instrument is then shown. Once the sensor
starts to read gas, the calibration begins. The user has 5 minutes to apply gas before the
calibration times out. Gas should be applied at a flow rate of 0.5 lpm. If the user chooses to skip
the sensor, the instrument will move to the next sensor. The Abort option aborts the calibration
and shows the Cal Complete screens.
When the calibration is finished, the following screen shows the passed, marginal, skipped, and
failed sensors, when six sensors are installed. All passing sensors must first pass a zero check.
20
INDUSTRIAL SCIENTIFIC
MX6 iBrid™ Multi-Gas Monitor
Operation Guide
Bump TEST Option
Under the main menu [Sensor] option, there is a [Bump Test]
menu option.
If the [Bump Test] option is selected, a confirmation screen is
displayed. If Cancel is selected, the user is returned to the
NRS. If the user selects OK, all the installed sensors are
bump tested, starting with the first sensor.
The screen to alert the user to apply gas to the instrument is then shown. The user has a fixed
number of seconds to apply gas and select Start before the bump times out. If the user selects
Skip, the bump for this particular sensor is not done. The instrument moves on to the next sensor
in the list.
If the user selects Start, the bump test is started for this sensor. The sensor must reach a gas
reading of 50% or greater (user selectable in configuration menu) of the applied gas (calibration)
concentration within 60 seconds (user selectable in configuration menu) to pass. Once the sensor
has done so, the word “pass” is displayed for 3 seconds before the instrument moves on to the
next sensor.
After all the sensors installed in the instrument have been bump tested, a result screen is shown.
The user must acknowledge this screen to continue, by selecting the OK button. If all the
sensors have passed the bump test, the instrument goes into NRS. If any sensor failed the bump
test, after viewing and acknowledging the results, the instrument asks the user to continue, or
calibrate the failing sensor(s). If the user selects the Cancel button, the sensor is not calibrated
and the instrument moves on to the next sensor in the list. If the user selects OK, the failing
sensor is calibrated.
If there is more than one sensor that failed the bump test, they are calibrated in order (top row
left to right, bottom row left to right on the Normal Readings screen), one at a time – each time
prompting the user to choose whether to calibrate the sensor or not.
INDUSTRIAL SCIENTIFIC
21
Operation Guide
MX6 iBrid™ Multi-Gas Monitor
Datalog Menu Options
22
INDUSTRIAL SCIENTIFIC
MX6 iBrid™ Multi-Gas Monitor
Operation Guide
Configuration Menus
These are similar to the earlier menus, but these menus provide a deeper layer of access for
detailed operational configuration of the device. As such, the settings presented in these three
chapters should only be adjusted by experienced personnel, as inadvertent or accidental changes
to these settings could alter the devices operation significantly. To prevent inadvertent or
accidental changes to these critical parameters, these settings, which are collectively referred to
as the “Configuration/Administration Menus,” are password protected.
Options of the Admin menu include the following:





Password
Clock
Language
Company
Defaults
(Setting passwords)
(Setting time and date)
(Language settings)
(Company information)
(Restoring default settings).
The [Config] [Alarms] menu option allows the user to setup the alarms. Each of these alarm
options are checkbox items which can be toggled between checked and unchecked by focusing
on it and pressing enter.
INDUSTRIAL SCIENTIFIC
23
Operation Guide
MX6 iBrid™ Multi-Gas Monitor
If any two of these alarms are disabled and the user checks the box to disable the third alarm, a
screen is displayed to verify this action. Selecting OK disables the third and final alarm. A
screen is displayed, notifying the user of the action.
If all 3 alarms are disabled, “ALARMS OFF!” is displayed on the bottom of the NRS in red.
24
INDUSTRIAL SCIENTIFIC
MX6 iBrid™ Multi-Gas Monitor
Operation Guide
SENSOR SPECIFICATIONS AND CORRELATION FACTORS
Sensor specifications
Sensor properties
Accuracy
Response time
degrees (°)
(%)
-20°C to 55°C
(-4°F to 131°F)
Over full sensor
temperature and
RH ranges
Sensor RH
2
range
(%vol, %LEL, or ppm)
At temperature
of calibration
Sensor
temperature
2
range
Measurement
range
Measurement
resolution
Gas Names
Sensor technology1
Sensor Category
Abbreviation
(typical)
T50
T90
Seconds (s)
(%)
(%)
5 to 95
± 0.5
± 0.8
5
10
Oxygen
Oxygen
0% to 30%
vol
O2
E
Combustible
LEL
C
0% to
100% LEL
1% LEL
-20°C to 55°C
(-4°F to 131°F)
15 to 95
± 5.0
± 15.0
15
35
Combustible
LEL
IR
0% to
100% LEL
1% LEL
-20°C to 50°C
(-4°F to 122°F)
0 to 95
± 5.0
± 15.0
15
35
Methane
CH4
IR
0% to
100% LEL
1% LEL
-20°C to 50°C
(-4°F to 122°F)
0 to 95
± 5.0
± 15.0
10
25
Methane
CH4
C
0% to 5%
vol
0.01% vol
-20°C to 55°C
(-4°F to 131°F)
15 to 95
± 5.0
± 15.0
15
35
Ammonia
NH3
E
-20°C to 40°C
(-4°F to 104°F)
15 to 95
± 5.0
± 15.0
30 s
80 s
Carbon Dioxide
CO2
IR
0% to 5%
vol
0.01% vol
-20°C to 50°C
(-4°F to 122°F)
0 to 95
± 5.0
± 15.0
10 s
25 s
Carbon Monoxide
CO
E
0 to 1,500
ppm
1.00 ppm
-20°C to 50°C
(-4°F to 122°F)
15 to 90
± 5.0
± 15.0
15 s
50 s
Carbon Monoxide
CO
E
0 to 9,999
ppm
1.00 ppm
-20°C to 50°C
(-4°F to 122°F)
15 to 90
± 5.0
± 15.0
15 s
50 s
CO
E
0 to 1,500
ppm
1.00 ppm
-20°C to 50°C
(-4°F to 122°F)
15 to 90
± 5.0
± 15.0
15 s
50 s
H2 S
E
0 to 500
ppm
0.10 ppm
-20°C to 55°C
(-4°F to 131°F)
15 to 95
± 5.0
± 15.0
15 s
50 s
0.10% vol
Combustible
Toxic
Carbon Monoxide and
Hydrogen Sulfide
(COSH sensor)
0 to 500
ppm
1.00 ppm
INDUSTRIAL SCIENTIFIC
25
Operation Guide
MX6 iBrid™ Multi-Gas Monitor
Sensor specifications
Sensor properties
Accuracy
Response time
degrees (°)
(%)
-20°C to 40°C
(-4°F to 104°F)
15 to 90
0 to 50
ppm
0.10 ppm
Over full sensor
temperature and
RH ranges
(%vol, %LEL, or ppm)
At temperature
of calibration
Measurement
range
E
Sensor RH
2
range
Cl2
Sensor
temperature
2
range
Chlorine
Measurement
resolution
Gas Names
Sensor technology1
Sensor Category
Abbreviation
(typical)
(%)
± 10.0
(%)
Varies*
T50
T90
Seconds (s)
25 s
120 s
*For the Cl2 sensor, accuracy over the “full sensor temperature and RH ranges” is based on temperature range: ± 15.0% from -20°C to 40°C (-4°F to
104°F); and ± 25.0% from 41°C to 50°C (106°F to 122°F).
Chlorine Dioxide
ClO2
E
0 to 1 ppm
0.01 ppm
-20°C to 40°C
(-4°F to 104°F)
15 to 95
± 5.0
± 15.0
30 s
120 s
Hydrogen
H2
E
0 to 2,000
ppm
1.00 ppm
-20°C to 50°C
(-4°F to 122°F)
15 to 90
± 5.0
± 15.0
35 s
120 s
Hydrogen Chloride
HCl
E
0 to 30
ppm
0.10 ppm
-20°C to 40°C
(-4°F to 104°F)
15 to 95
± 5.0
± 15.0
50 s
150 s
Hydrogen Cyanide
HCN
E
0 ppm to
30 ppm
0.10 ppm
-40°C to 40°C
(-40°F to 104°F)
15 to 90
± 5.0
± 15.0
25 s
80 s
Hydrogen Sulfide
H2 S
E
0 to 500
ppm
0.10 ppm
-20°C to 50°C
(-4°F to 122°F)
15 to 90
± 5.0
± 15.0
15 s
50 s
Nitrogen Dioxide
NO2
E
0 to 150
ppm
0.10 ppm
-20°C to 50°C
(-4°F to 122°F)
15 to 90
± 5.0
± 15.0
15 s
50 s
Nitric Oxide
NO
E
0 to 1,000
ppm
1.00 ppm
-20°C to 50°C
(-4°F to 122°F)
15 to 90
± 5.0
± 15.0
15 s
50 s
Phosphine
PH3
E
0 to 5 ppm
0.01 ppm
-20°C to 40°C
(-4°F to 104°F)
20 to 95
± 5.0
± 15.0
10 s
30 s
Phosphine
PH3
E
0 to 1,000
ppm
1.00 ppm
-20°C to 50°C
(-4°F to 122°F)
15 to 90
± 5.0
± 15.0
10 s
50 s
Sulfur Dioxide
SO2
E
0 to 150
ppm
0.10 ppm
-20°C to 50°C
(-4°F to 122 °F)
15 to 90
Varies**
± 15.0
10 s
30 s
**For the SO2 sensor, accuracy at the “temperature of calibration” is based on measurement range: ± 5.0% or 1 ppm (whichever is greater) from 0 ppm
to 20 ppm; and ± 15.0% for 21 ppm to 150 ppm.
Volatile Organic
Compounds
1
2
VOC
10.6 eV
(PID)
0 to 2,000
ppm
0.10 ppm
-20°C to 50°C
(-4°F to 122°F)
0 to 90
± 10.0
± 20.0
Sensor technology: "C" stands for catalytic, "E" for electrochemical, "IR" for infrared, and "PID" for photoionization detector.
During continuous operation.
26
INDUSTRIAL SCIENTIFIC
15 s
50 s
MX6 iBrid™ Multi-Gas Monitor
Operation Guide
LEL and LEL correlation factors for combustible gases
Sample gas*
LEL
(% vol)
LEL correlation factors
Calibration gas
Butane
Hexane
Hydrogen
Methane
Pentane
Propane
Acetone
2.5%
1.00
0.70
1.70
1.70
0.90
1.10
Acetylene
2.5%
0.70
0.60
1.30
1.30
0.70
0.80
Benzene
1.2%
1.10
0.80
1.90
1.90
1.00
1.20
Butane
1.9%
1.00
0.58
1.78
1.67
0.83
1.03
Ethane
3.0%
0.80
0.60
1.30
1.30
0.70
0.80
Ethanol
3.3%
0.89
0.52
1.59
1.49
0.74
0.92
Ethylene
2.7%
0.80
0.60
1.40
1.30
0.70
0.90
Hexane
1.1%
1.71
1.00
3.04
2.86
1.42
1.77
Hydrogen
4.0%
0.56
0.33
1.00
0.94
0.47
0.58
Isopropanol
2.0%
1.10
0.90
2.00
1.90
1.00
1.20
Methane
5.0%
0.60
0.35
1.06
1.00
0.50
0.62
Methanol
6.0%
0.60
0.50
1.10
1.10
0.60
0.70
Nonane
0.8%
2.22
1.30
3.95
3.71
1.84
2.29
Pentane
1.4%
1.21
0.71
2.15
2.02
1.00
1.25
Propane
2.1%
0.97
0.57
1.72
1.62
0.80
1.00
Styrene
0.9%
1.30
1.00
2.20
2.20
1.10
1.40
Toluene
1.1%
1.53
0.89
2.71
2.55
1.26
1.57
Xylene
1.1%
1.50
1.10
2.60
2.50
1.30
1.60
JP-4
—
—
—
—
—
1.20
—
JP-5
—
—
—
—
—
0.90
—
JP-8
—
—
—
—
—
1.50
—
NOTE: The table above provides the LEL for select combustible gases*. It also provides correlation factors that help
the safety technician and instrument operator determine the actual percentage LEL when the sample gas differs from
the gas that was used to calibrate the unit.
For example, if the unit reads 10% LEL in a pentane atmosphere, and was calibrated to methane, the actual
percentage LEL is determined as follows:
1.
Locate the table cell where the sample gas (pentane) intersects with the calibration gas (methane).
2.
Multiply the cell's value (2.02) by the unit's LEL reading (10%) to calculate the actual concentration of
20.2% LEL.
* The combustible gas list is not a comprehensive list of all combustible gases that can be detected by the MX6. For
additional information about combustible gas detection and the MX6, contact the ISC Technical Service department.
INDUSTRIAL SCIENTIFIC
27
Operation Guide
MX6 iBrid™ Multi-Gas Monitor
WARRANTY
Industrial Scientific Corporation’s MX6 iBrid™ portable gas monitors are warranted to be free
from defects in material and workmanship under normal and proper use and service for as long
as the instrument is supported by Industrial Scientific Corporation.
The above warranty does not include sensors, battery packs, and internal pumps, which are
warranted to be free from defects in material and workmanship for 24 months from date of
shipment, except where otherwise stated in writing in Industrial Scientific literature
accompanying the product.
Limitation of Liability
THE WARRANTY SET FORTH ABOVE IS STRICTLY LIMITED TO ITS TERMS
AND IS IN LIEU OF ALL OTHER WARRANTIES, GUARANTEES, EXPRESS OR
IMPLIED, ARISING BY OPERATION OF LAW, COURSE OF DEALING, USAGE OF
TRADE OR OTHERWISE. INDUSTRIAL SCIENTIFIC MAKES NO OTHER
WARRANTIES, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT
LIMITED TO THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR
PARTICULAR PURPOSE.
SHOULD THE PRODUCT FAIL TO CONFORM TO THE ABOVE WARRANTY, BUYER’S
ONLY REMEDY AND INDUSTRIAL SCIENTIFIC’S ONLY OBLIGATION SHALL BE, AT
INDUSTRIAL SCIENTIFIC’S SOLE OPTION, REPLACEMENT OR REPAIR OF SUCH
NON-CONFORMING GOODS OR REFUND OF THE ORIGINAL PURCHASE PRICE OF
THE NONCONFORMING GOODS.
IN NO EVENT WILL INDUSTRIAL SCIENTIFIC BE LIABLE FOR ANY OTHER SPECIAL,
INCIDENTAL OR CONSEQUENTIAL OR OTHER SIMILAR DAMAGES, INCLUDING
LOSS OF PROFIT OR LOSS OF USE, ARISING OUT OF THE SALE, MANUFACTURE OR
USE OF ANY PRODUCTS SOLD HEREUNDER WHETHER SUCH CLAIM IS PLEADED
IN CONTRACT OR IN TORT, INCLUDING STRICT LIABILITY IN TORT AND
WHETHER INDUSTRIAL SCIENTIFIC HAS BEEN ADVISED OF THE POTENTIAL FOR
SUCH DAMAGES.
Industrial Scientific’s total liability hereunder from any cause whatsoever (except liability from
personal injury caused by Industrial Scientific’s negligence), whether arising under contract,
warranty, tort (including negligence), strict liability, products liability or any other theory of
liability, will be limited to the lesser of Buyer’s actual damages or the price paid to Industrial
Scientific for the Products that are the subject of Buyer’s claim. All claims against Industrial
Scientific must be brought within one year after the cause of action arises, and Buyer expressly
waives any longer statute of limitations.
28
INDUSTRIAL SCIENTIFIC
MX6 iBrid™ Multi-Gas Monitor
Operation Guide
It shall be an express condition to Industrial Scientific’s warranty that all products be carefully
inspected for damage by Buyer upon receipt, be properly calibrated for Buyer’s particular use,
and be used, repaired, and maintained in strict accordance with the instructions set forth in
Industrial Scientific’s product literature. Repair or maintenance by non-qualified personnel will
invalidate the warranty, as will the use of non-approved consumables or spare parts. As with any
other sophisticated product, it is essential and a condition of Industrial Scientific’s warranty that
all personnel using the products be fully acquainted with their use, capabilities and limitations as
set forth in the applicable product literature.
Buyer acknowledges that it alone has determined the intended purpose and suitability of the
goods purchased. It is expressly agreed by the parties that any technical or other advice given by
Industrial Scientific with respect to the use of the goods or services is given without charge and
at Buyer’s risk; therefore, Industrial Scientific assumes no obligations or liability for the advice
given or results obtained.
  
INDUSTRIAL SCIENTIFIC
29
Operation Guide
do
30
wykorzystania
MX6 iBrid™ Multi-Gas Monitor
jako
skrócony
kurs
INDUSTRIAL SCIENTIFIC
obsługi
detektora.
MX6 iBrid™ Multi-Gas Monitor
Operation Guide
iBrid™ and MX6 iBrid™ are trademarks of Industrial Scientific Corporation.
All trademarks and registered trademarks are the property of their respective owners.
These help materials or any part thereof may not, without the written consent of Industrial
Scientific Corporation, be copied, reprinted or reproduced in any material form including but not
limited to photocopying, transcribing, transmitting or storing it in any medium or translating it
into any language, in any form or by any means, be it digitally, electronic, mechanical,
xerographic, optical, magnetic or otherwise.
The information contained in this document is proprietary and confidential and all copyright,
trade marks, trade names, patents and other intellectual property rights in the documentation are
the exclusive property of Industrial Scientific Corporation unless otherwise specified. The
information (including but not limited to data, drawings, specification, documentation, software
listings, source or object code) shall not at any time be disclosed directly or indirectly to any
third party without prior written consent.
The information contained herein is believed to be accurate and reliable. Industrial Scientific
Corporation accepts no responsibility for its use by any means or in any way whatsoever
Industrial Scientific Corporation shall not be liable for any expenses, costs by damage that may
result from the use of the information contained within this document. The information
contained herein is subject to change without notice.
Industrial Scientific Corporation
1001 Oakdale Road
Oakdale, PA 15071-1500
USA
Phone: 412-788-4353
Toll Free: 1-800-DETECTS (1-800-338-3287)
Fax: 412-788-8353
Service: 1-888-788-4353
Web: www.indsci.com
Although every effort is made to ensure accuracy, the specifications of this product and the
content herein are subject to change without notice.
©2007, 2009, 2011, 2012, and 2013 Industrial Scientific. All rights reserved.
INDUSTRIAL SCIENTIFIC
31
Operation Guide
MX6 iBrid™ Multi-Gas Monitor
Ex-Ox-Tox Gasdetectie
Westerdreef 5V
2152 CS Nieuw-Vennep
Telefoon: 0252 620885
E-mail: info@exoxtox.nl
Website: www.exoxtox.nl
32
INDUSTRIAL SCIENTIFIC
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising