SC-Series Commercial Scale Elimination Systems Featuring Watts

SC-Series Commercial Scale Elimination Systems Featuring Watts
BUILT IN THE USA
SC-Series
Commercial Scale
Elimination Systems
Featuring Watts
OneFlow™ Technology
No Scale
No Waste
Minimal Pressure Loss
Total Satisfaction
Water Control Corporation is pleased to bring you the very latest in environmentally-friendly
scale prevention technology. SC-Series Scale Elimination Systems combine our expertise as a
regional leader in water conditioning and filtration with the benefits of Watts Water Technologies’
breakthrough, OneFlow™ media.
SC-Series systems completely protect fixtures and plumbing systems from the build-up of hard
scale residue. While they do not provide the same bather benefits as commercial water softeners
(i.e. soft skin and hair), they require no electricity, salt, chemicals, or backwash water. Moreover,
they generate virtually no system pressure loss, and occupy far less space in the mechanical room.
Whether you are seeking a cost-effective means for protecting your boilers, dishwashers, and heat
exchangers -- or a “green” solution for protecting an entire plumbing system – a Water Control SCSeries System may be the solution.
How They Work:
SC-Series Scale Elimination Systems provide protection from scale formation on internal and
external plumbing surfaces. These systems may be installed at the point-of-entry to a building to
treat both hot* and cold water, or they can be located directly before a water heater, boiler, or other
hot* water-using device that requires protection from the ill effects of hard water.
OneFlow™ media prevents hard scale via a molecular process called Template-Assisted
Crystallization. Dissolved calcium carbonate (CaC03) is prematurely drawn out of solution by
OneFlow™ media’s strong ionic attraction and irregular surfaces. CaC03 adheres to the media
beads and forms soft crystals, which eventually detach, and are released into the plumbing system.
The energy required for remaining CaCO3 to adhere to these soft CaC03 crystals is far lower than
what is required for adhesion to any other surfaces in a plumbing system. As a result, any remaining
CaC03 coming out of solution binds to the free-floating soft crystals (rather than attaching itself to
surfaces in the plumbing system). In fact, even existing hard scale in a plumbing system will typically
break away and bond with the soft crystals, thereby serving to de-scale the system. The soft
crystals remain suspended in the water and are eventually passed to drain, eliminating hard scale
build-up, water spots, and soap scum. The only evidence of CaC03 soft crystals is an occasional
thin layer of harmless white powder residue, which can be easily wiped away from fixtures and
equipment. The system requires very little maintenance, no backwashing, no salt, and no electricity.
Typical hardness problems -- especially build-up of scale in pipes, water heaters, boilers, and on
fixtures -- are no longer a concern.
SC-Series Systems are not water softeners, nor do they work via chemical additives (like antiscalants or sequesterants). They are scale prevention systems with proven third party test data and
years of successful residential and commercial applications. They are the only non-water softener,
non-chemical-based systems to have undergone rigorous independent laboratory examination
-- and to have been certified to work at an effective level (99.6% to be precise) when applied and
installed properly.
Features
•
•
•
•
•
•
•
•
•
Chemical free scale prevention and protection – converts hardness minerals to harmless,
inactive microscopic crystals making SC-Series Systems effective alternative technology to
water softeners for the prevention of scale due to water hardness.
Virtually maintenance free – No salt bags or other chemicals to constantly add.
No control valve, no electricity and no wastewater.
Uses environmentally friendly “green” technology.
Improves efficiency of all water-using appliances – both hot* and cold.
Simple sizing & installation – all you need to know is pipe size and the peak flow rate.
Perfect system for towns or communities where water softeners are banned or restricted.
OneFlow™ media does not remove minerals or add sodium to the water supply.
SC-Series Systems can be installed as a pre-treatment to reverse osmosis (The SC-System
should be the last stage in treatment unless a point-of-use system is being used downstream).
*For hot water applications where water temperature is 110°F – 150°F (43°C – 63°C), please
refer to pages 10-11 (Series SCH-500).
2
Models SC100-1, SC100-2 and SC100-4
Low-Flow Cartridge Systems
C
Perfect for
- Small Water Heaters
- Hot Beverage Systems
- Small Appliances
Models
Model
Maximum Flow Rate
SC100 – 1
1 gpm (4 lpm)
Connection Sizes
⁄ ” (15mm) FNPT
12
SC100 – 2
2 gpm (8 lpm)
12
SC100 – 4
4 gpm (15 lpm)
34
⁄ ” (15mm) FNPT
⁄ ” (20mm) FNPT
Replacement Cartridge
SC100-1M
Cartridge should be replaced every 12 months
SC100-2M
Cartridge should be replaced every 12 months
SC100-4M
Cartridge should be replaced every 12 months
D
B
E
A
SC100-1
SC100-4
SC100-2
Dimensions — Weights
Model
A
SC100-1
SC100-2
SC100-4
in.
141⁄2
241⁄2
26
B
mm
37
62
66
in.
41⁄2
41⁄2
73⁄4
mm
11
11
20
Dimensions
C
in.
mm
51⁄8
13
51⁄8
13
85⁄8
22
Weight
D
in.
65⁄8
65⁄8
913⁄16
E
mm
17
17
25
in.
21⁄2
21⁄2
53⁄4
mm
6
6
15
lbs.
5
8
18
The overall height and the height of the inlet fitting varies due to material variations and assembly
tolerances. Please allow additional clearance above the tank for making connections.
3
kgs
2.3
3.6
8.2
Models SC200-1, SC200-2 and SC200-4
Low-Flow Cartridge Systems With Taste/Odor Filter
Perfect for:
- Coffee makers
- Espresso machines
- Post-mix systems
- Steamers
D
C
Models
B
E
Model
SC200 – 1
A
Maximum Flow Rate
1 gpm (4 lpm)
Connection Sizes
⁄ ” (15mm) FNPT
12
SC200 – 2
2 gpm (8 lpm)
12
SC200 – 4
4 gpm (15 lpm)
34
⁄ ” (15mm) FNPT
⁄ ” (20mm) FNPT
Replacement Cartridge
A
SC200-1M
Cartridge should be replaced every 12 months
SC200-2M
Cartridge should be replaced every 12 months
SC200-4M
Cartridge should be replaced every 12 months
SC200-1C
Cartridge should be replaced every 6 months
SC200-2C
Cartridge should be replaced every 6 months
SC200-4C
Cartridge should be replaced every 6 months
Clearance
SC200-1
SC200-2
SC200-4
Dimensions — Weights
Model
SC200-1
SC200-2
SC200-4
in
141⁄2
241⁄2
26
A
mm
37
62
66
in
91⁄4
91⁄4
151⁄4
B
mm
24
24
39
Dimensions
C
in
mm
51⁄8
13
51⁄8
13
85⁄8
22
Weight
in
111⁄4
111⁄4
175⁄16
D
mm
29
29
44
in
53⁄4
53⁄4
121⁄4
E
mm
15
15
31
lbs.
9
14
31
The overall height and the height of the fitting varies due to material variations and assembly
tolerances. Please allow additional clearances above the tank for making connections.
4
kgs.
4.1
6.4
14.1
Temperature
41°F to 140°F (5 to 60°C)
Chlorine
< 3 ppm
Iron (maximum)
0.3 mg/l
Manganese (maximum)
0.05 mg/l
1.3 mg/l
Series SC100 and SC200 Series Cartridge Systems
Copper (maximum)
Oil & H2S
Engineer Data
Water Chemistry & Limitations
pH
6.5 to 8.5
Hardness (maximum)
75 grains (1300 ppm CaCO3)
Temperature
41°F to 140°F (5 to 60°C)
Chlorine
< 3 ppm
Iron (maximum)
0.3 mg/l
Manganese (maximum)
0.05 mg/l
Copper (maximum)
1.3 mg/l
Oil & H2S
none allowed
Polyphosphate
none allowed
Silica (maximum)
10 ppm
none allowed
Polyphosphate
none allowed
Silica (maximum)
10 ppm
Standards
DVGW – German Technical and Scientific Association for Gas &
Water
OneFlow™ meets standard W-512 for testing Physical Water
Treatment devices for Scale Prevention and achieved an efficiency rating of 99.6% for scale prevention.
OneFlow™ media has been tested and certified for material
safety to NSF/ANSI Standard 42 and 61.
Standards
DVGW – German Technical and Scientific Association for Gas &
SC100
Series: Cartridge Systems
SC200 Series: Cartridge Systems
Water
Specifications
with Taste and Odor Filters
OneFlow™ meets standard W-512 for testing Physical Water
Treatment
devices model
for Scale
Prevention and achieved
A
Water Control
SC100-__________
Scalean effiSpecifications
ciency ratingSystem
of 99.6%shall
for scale
prevention.
Elimination
be installed
on the cold water
OneFlow™
media
has
been
tested
and certified
for material
service line to condition the tap water
just prior
to
safety
to
NSF/ANSI
Standard
42
and
61.
the service line feeding the equipment it is designed
to protect. The scale elimination system shall feature
OneFlow™ media, as manufactured by Watts Water
Technologies, to initiate Template-Assisted Crystallization
of CaCO3. The system will be sized for maximum or peak
flow rate based on the specification of said equipment.
An SC-Series system may also be installed to protect
multiple pieces of equipment from the ill-effects of hard
water scale provided the aggregate peak flow rate
for each piece of equipment it is protecting has been
considered. The system shall be plumbed with a bypass
valve to allow isolation of filter housing to allow the
bypass of untreated water in the event that service or
cartridge replacement is necessary. The installation area
should be suitable in size for the housing to be serviced
without encumbrance and the system should be installed
per the Installation, Operation & Maintenance manual as
provided with each system.
A Water Control model SC200-__________ Scale
Elimination System with added carbon filter shall be
installed on the cold water service line to condition and
filter the tap water just prior to the service line feeding the
equipment it is designed to protect. The scale elimination
system shall feature OneFlow™ media, as manufactured
by Watts Water Technologies, to initiate Template-Assisted
Crystallization of CaCO3. The system will be sized for
maximum or peak flow rate based on the specification of
said equipment. An SC-Series system with added carbon
filter may also be installed to protect multiple pieces of
equipment from the ill-effects of hard water scale and
taste/odor concerns provided the aggregate peak flow
rate for each piece of equipment it is protecting has
been considered. The system shall be plumbed with a
bypass valve to allow isolation of filter housings to allow
the bypass of untreated water in the event that service or
cartridge replacement is necessary. The installation area
should be suitable in size for the housing to be serviced
without encumbrance and the system should be installed
per the Installation, Operation & Maintenance manual as
provided with each system.
The scale elimination system must not require additional
waste water to backwash, flush, or regenerate once put
into service. The system shall not require any chemical
additives and shall not require electricity for operation.
Scale reduction potential shall be third party certified to
99.6% effectiveness or better.
The scale elimination system must not require additional
waste water to backwash, flush, or regenerate once put
into service. The system shall not require any chemical
additives and shall not require electricity for operation.
Scale reduction potential shall be third party certified to
99.6% effectiveness or better.
5
Models SC300-10, 12, 16, 20 and 30
Commercial Scale Elimination
Systems up to 30 GPM
Perfect for:
- Domestic water systems
- Boiler feeds (domestic hot water only)
- Water heater feeds
- Commercial dishwashers
Models
Model
Maximum
Flow Rate
Connection Sizes
SC300-10
10 gpm (38 lpm)
34
SC300-12
12 gpm (54.5 lpm)
34
SC300-16
16 gpm (60.8 lpm)
34
SC300-20
20 gpm (76 lpm)
34
SC300-30
30 gpm (114 lpm)
34
⁄ ", 1" or 11⁄4" (20, 25, 32mm)
⁄ ", 1" or 11⁄4" (20, 25, 32mm)
⁄ ", 1" or 11⁄4" (20, 25, 32mm)
⁄ ", 1" or 11⁄4" (20, 25, 32mm)
⁄ ", 1" or 11⁄4" (20, 25, 32mm)
Connection Options
SC300-10
SC300-12
SC300-16
SC300-20
SC300-30
D
⁄ " and 1" Sweat (20 and 25mm)
34
1" and 11⁄4" Plastic MPT (25 and 32mm)
Replacement Media
SC300-10M
Media should be replaced every 3 years
SC300-12M
Media should be replaced every 3 years
SC300-16M
Media should be replaced every 3 years
SC300-20M
Media should be replaced every 3 years
SC300-30M
Media should be replaced every 3 years
A
B
Dimensions
Model
Dimensions
C
D
E
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
SC300-10
481⁄2
1232
46
1168
7
178 2 1⁄2
64
3
76
SC300-12
481⁄2
1232
46
1168
8
203 2 1⁄2
64
3
76
SC300-16
521⁄2
1334
48
1219
9
229 2 1⁄2
64
3
76
SC300-20
591⁄2
1511
57
1448
10
254 2 1⁄2
64
3
76
SC300-30
561⁄2
1435
54
1372
12
305 2 1⁄2
64
3
76
The overall height and the height of the fitting varies due to material variations and assembly tolerances.
Please allow additional clearances above the tank for making connections.
A
B
C
E
Peak Flow Rates — Weights
SC300-10
SC300-12
SC300-16
*Maximum Flow
10 gpm
37.8 lpm
12 gpm
45.4 lpm
Dry Weight
22 lbs.
10.0 kgs.
25 lbs.
11.3 kgs.
Service Weight
80 lbs.
36.3 kgs.
97 lbs.
44.0 kgs.
*Exceeding maximum flow can reduce effectiveness and void warranty.
6
16 gpm
29 lbs.
129 lbs.
60.6 lpm
13.2 kgs.
58.5 kgs.
SC300-20
20 gpm
35 lbs.
168 lbs.
75.7 lpm
15.9 kgs.
76.2 kgs.
SC300-30
30 gpm
43 lbs.
235 lbs.
113.6 lpm
19.5 kgs.
106.6 kgs.
Models SC300-50 and 75
Commercial Scale Elimination
Systems up to 75 GPM
Perfect for:
- Domestic water systems
- Boiler feeds (domestic hot water only)
- Water heater feeds
- Commercial dishwashers
Peak Flow Rates - Weights
SC300-50
54 lbs.
31.8 kgs.
350 lbs.
158.8 kgs.
Dry Weight
Service Weight
SC300-75
88 lbs.
30.8 kgs.
420 lbs.
190.6 kgs.
Outlet
Models
Model
Maximum Flow Rate
SC300-50
50 gpm (189.3 lpm)
SC300-75
75 gpm (283.9 lpm)
Connections
Inlet Connection
2" (50mm) PVC Union with 90° Socket
Outlet Connection
2" (50mm) PVC Socket
B
C
Replacement Media
SC300-50M
Media should be replaced every 3 years
SC300-75M
Media should be replaced every 3 years
D
Inlet
E
A
Dimensions
Model
Dimensions
C
D
E
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
SC300-50
17
432
14
356
79
2006
65
1651
10 1⁄4
260
SC300-75
17
432
16
406
79
2006
65
1651
10 1⁄2
267
The overall height and the height of the inlet fitting varies due to material variations and assembly
tolerances. Please allow additional clearance above the tank for making connections.
A
B
7
SC300-75
Series SC400: Models 100 – 450 Turnkey
Skid-mounted Systems
up to 450 GPM
Perfect for:
- Large domestic water systems
- Large domestic hot water systems (on cold water feeds)
- Industrial applications
Replacement Media
Media should be replaced every 3 years
(replacement media model SC400-___M)
PVC
Socket
Connection
Bypass
Assembly
Ball
Valve
System
Outlet
PVC Socket
Connections
{
C
C
System
Inlet
Support
Strut
Piping
Support
Drain Valve
B
Side View
A
A
Skid
Skid
weiV tnorF
Front View
PVC
Socket
Connection
B
Side View
Dimensions – Weights
Model
Max Flow
(gpm)
Tank
Diameter(s)
No. of
Tanks
System Dimensions
(A X B X C)
Inlet Height
(to center)
Outlet Height
(to center)
Manifold Pipe
Connections
Approx. System
Weight (dry)
SC400-100
100
14”
2
50” X 30” X 92”
50”
68”
2” (SWT)
188 lbs.
SC400-150
150
16”
2
54” X 32” X 92”
50”
68”
225
16”
3
70” X 32” X 92”
50”
68”
SC400-300
300
16”
4
94” X 38” X 96”
44”
44”
SC400-375
375
16”
5
110” X 38” X 96”
44”
44”
SC400-450
450
16”
6
126” X 38” X 96”
44”
44”
32” (SWT)
32” (SWT)
43” (SWT)
43” (SWT)
63” (SWT)
266 lbs.
SC400-225
*Dimensions may be subject to change without notice.
8
374 lbs.
472 lbs.
575 lbs.
673 lbs.
Iron (maximum)
0.3 mg/l
Manganese (maximum)
0.05 mg/l
Copper (maximum)
1.3 mg/l
Oil & H2S
None allowed
Polyphosphate
None allowed
Silica (maximum)
10 ppm
Note: Water known to have heavy loads of dirt and debris
should be strained prior to OneFlow™ using a wye-pattern
strainer (100 mesh) or equivalent.
SC300 and SC400 Series Commercial Systems
Engineer Data
Feed Water Chemistry Requirements
Standards
pH
6.5 to 8.5
Hardness (maximum)
75 grains (1300 ppm CaCO3)
Water Pressure
15psi to 100psi (103 kPa to 6.9 bar)
Temperature
40°F to 110°F (5°C to 43°C)*
Chlorine
< 3ppm
Iron (maximum)
0.3 mg/l
Manganese (maximum)
0.05 mg/l
Copper (maximum)
1.3 mg/l
Oil & H2S
None allowed
Polyphosphate
None allowed
Silica (maximum)
10 ppm
Note: Water known to have heavy loads of dirt and debris
should be strained prior to OneFlow™ using a wye-pattern
strainer (100 mesh) or equivalent.
DVGW – German Technical and Scientific Association for Gas
& Water
OneFlow™ meets standard W-512 for testing Physical Water
Treatment devices for Scale Prevention and achieved an efficiency rating of 99.6% for scale prevention.
*For hot water applications where water temperature is 110°F
– 150°F, please consult ES-OneFlow-HotWater.
OneFlow™ media has been tested and certified for material
safety to NSF/ANSI Standard 42 and 61.
Standards
SC300
Series:
DVGW – German
Technical and Scientific Association for Gas
&
Water
Commercial (Single-tank) Systems
OneFlow™ meets standard W-512 for testing Physical Water
Specifications
Treatment devices for Scale Prevention and achieved an effi-
SC400 Series:
Turnkey (Multi-tank) Skid Systems
Specifications
ciency
rating
of 99.6%
forSC300-__________Series
scale prevention.
A
Water
Control
model
Scale
Elimination
System
shall be
installed
the mainiswater
*For hot water
applications
where
water on
temperature
110°F
– 150°F, pipe
please
consult
service
just
after itES-OneFlow-HotWater.
enters the building, but after other
whole
building
water
safety
devices
OneFlow™
media
has been
tested
and (backflow
certified forpreventers
material
safety
to NSF/ANSI
Standard
42to
and
61.
or
pressure
reducing
valves),
effectively
address
water hardness concerns. The scale elimination system
shall feature OneFlow™ media, as manufactured by
Watts Water Technologies, to initiate Template-Assisted
Crystallization of CaCO3. A system may also be installed
further downstream to protect specific equipment or
areas within a plumbing system. The system shall be
plumbed with a bypass valve to allow isolation of tank
and to allow the bypass of untreated water usage in the
event that service or media replacement is necessary.
The installation area should be suitable in size for the
tank to be serviced without encumbrance and sit upright
on a flat level surface.
A Water Control Corporation model SC400-_____ Scale
Elimination System shall be installed on the main water
service pipe just after it enters the building, but after
other whole building water safety devices (backflow
preventers or pressure reducing valves), to effectively
address water hardness concerns. The scale elimination
system shall feature OneFlow™ media, as manufactured
by Watts Water Technologies, to initiate TemplateAssisted Crystallization of CaCO3. A system may also
be installed further downstream to protect specific
equipment of areas within a plumbing system. The entire
system shall be pre-plumbed in reverse-return manifold
configuration and securely fastened to a minimum
14 gauge, powder coated, heavy-duty, welded steel
skid. Manifold assembly (plumbed in 2” or 3” PVC, per
schedule) shall include system bypass, as well as ball
valves, drain valves, and socket connections for isolating,
draining, and removing each individual tank when media
replacement is required. The installation area should
be suitable in size for the tank(s) to be serviced without
encumbrance. Skid shall include adjustable feet to aid in
system leveling. Manifold inlet and outlet shall be located
on (left/right) side of skid, and shall be pre-plumbed with
PVC X copper sweat adaptors.
The scale elimination system must not require additional
wastewater to backwash, flush, or regenerate once put
into service. The system shall not require any chemical
additives and shall not require electricity for operation.
The system shall not require any chemical additives
and shall not require electricity for operation. Scale
reduction potential shall be third party certified to 99.6%
effectiveness or better.
The scale elimination system must not require additional
wastewater to backwash, flush, or regenerate once put
into service. The system shall not require any chemical
additives and shall not require electricity for operation.
Scale reduction potential shall be third party certified to
99.6% effectiveness or better.
9
Models SCH500 – 8, 12, 20 and 75
Commercial Hot Water Scale Elimination Systems
up to 75 GPM
Flow Rates: 2 gpm to 75 gpm (7.6 lpm to 285 lpm)
A Water Control SCH500 Series Scale Elimination System for hot water provides protection from scale formation on internal
and external surfaces where the hot water feed line is being further heated (booster heater) or brought to steam (steam
generator, autoclave). The SC-Series system uses specially designed components to work in applications where the water
is heated between 100°F – 150°F but has not yet been treated for scale control. These types of applications typically involve
protecting and extending the life of equipment and instruments from the damaging effects of hard water scale.
Models
Model
Maximum Flow Rate Connection Sizes
G (clearance)
SCH500-8
8 gpm (30.4 lpm)
1" (25mm) FNPT bypass
SCH500-12
12 gpm (45.6 lpm)
1" (25mm) FNPT bypass
SCH500-20
20 gpm (76 lpm)
1" (25mm) FNPT bypass
SCH500-75
75 gpm (285 lpm)
2" (50mm) Socket
D
Replacement Media
SCH500-8M
Media must be replaced every 3 years
SCH500-12M
Media must be replaced every 3 years
SCH500-20M
Media must be replaced every 3 years
SCH500-75M
Media must be replaced every 3 years
A
B
C
E
F
H
Dimensions — Weights
Model
Dimensions
A
SCH500-8
SCH500-12
SCH500-20
SCH500-75
in.
20
20
22
72
B
mm
508
508
559
1829
in.
18 5⁄8
18 5⁄8
20 5⁄8
69 1⁄2
C
mm
472
472
523
1765
in.
81⁄2
81⁄2
101⁄2
17
D
mm
216
216
267
432
in.
13⁄8
13⁄8
13⁄8
21⁄2
Weight
E
mm
36
36
36
64
10
in.
10
10
11
14
mm
254
254
279
356
in.
2
2
2
2
F
mm
51
51
51
51
in.
6
6
6
10
G
mm
152
152
152
254
in.
41⁄4
41⁄4
41⁄4
N/A
H
mm
108
108
108
N/A
lbs.
15
16
26
105
kgs
6.8
7.3
11.8
47.6
Models SCH500 Hot Water Systems
Engineer Data
Water Chemistry & Limitations:
pH
6.5 to 8.5
Hardness (max)
75 grains (1300 ppm CaCO3)
Temperature
100°F to 150°F (40°C to 70°C)
Chlorine
< 3ppm
Iron
0.3 mg/l
Manganese
0.05 mg/l
Copper
1.3 mg/l
Oil & H2S
none allowed
Polyphosphate
none allowed
Silica (max)
10 ppm
Standards
DVGW – German Technical and Scientific
Association for Gas & Water
OneFlow™ meets standard W-512 for
testing Physical Water Treatment devices
for Scale Prevention and achieved an
efficiency rating of 99.6% for scale
prevention.
OneFlow™ media and components have
been tested and certified for material
safety to NSF/ANSI Standard 42 & 61.
SCH500 Series: Hot Water Systems
Specifications
A Water Control model SC500-__________ Series Scale
Elimination System for hot water shall be installed on
the hot water feed line just prior to the equipment it
is intended to protect. The scale eliminatioin system
shall feature OneFlow™ media, as manufactured by
Watts Water Technologies, to initiate Template-Assisted
Crystallization of CaCO3. The temperature of the hot
water feed line should consistently range between 100°F
– 150°F (or 38°C – 66°C) as all of the components are
designed to work in this elevated temperature condition.
The OneFlow™ system shall effectively reduce water
hardness scale concerns thereby protecting heattransfer and other surfaces from the negative effects of
scale. The system shall be plumbed with a bypass valve
to allow isolation of tank(s) and to allow the bypass of
untreated hot water in the event that service or media
replacement be necessary. The installation area should
be suitable in size for the tank(s) to be serviced without
encumbrance and for the tank to sit upright on a flat
level surface.
The scale elimination system must not require
backwashing, regeneration or any need to discharge
water once put into service. The system must not
require any chemical additives and must not require
electricity for operation. The system must operate in an
up-flow manner to minimize any pressure drop. Scale
reduction potential shall be third party certified to 99.6%
effectiveness or better.
11
Water Control Corporation is ready to help you with:
·
System sizing and selection
·
CAD™ and Revit™ drawings
·
Installation and codes issues
·
Troubleshooting
Contact Our Technical Support Department:
Phone: 1-866-405-1268 • Fax: 763-427-5665
Email:techsupport@watercontrolinc.com
BUILT IN THE USA
Water Control Corporation
7150 143rd Ave NW • Ramsey, MN 55303
Phone: 866-405-1268 • Fax: 763-427-5665
www.watercontrolinc.com
© Water Control Corp. 0514
12