VNX System Operations Guide

VNX System Operations Guide
EMCé VNXé Series
Release 7.1
System Operations
P/N 300-013-448 Rev. 02
EMC Corporation
Corporate Headquarters:
Hopkinton, MA 01748-9103
1-508-435-1000
www.EMC.com
Copyright â 2011 - 2013 EMC Corporation. All rights reserved.
Published December 2013
EMC believes the information in this publication is accurate as of its publication date. The
information is subject to change without notice.
THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." EMC CORPORATION
MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO
THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Use, copying, and distribution of any EMC software described in this publication requires an
applicable software license.
For the most up-to-date regulatory document for your product line, go to the Technical
Documentation and Advisories section on EMC Powerlink.
For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on
EMC.com.
All other trademarks used herein are the property of their respective owners.
Corporate Headquarters: Hopkinton, MA 01748-9103
2
System Operations
Contents
Chapter 1: Introduction...........................................................................7
System requirements....................................................................................8
Limitations.....................................................................................................8
Considerations..............................................................................................8
Cautions........................................................................................................9
User interface choices...................................................................................9
Terminology.................................................................................................10
Related information.....................................................................................10
Chapter 2: Planned powerdown of the VNX.......................................11
Planned powerdown of VNX VG2/VNX VG8 Gateway system....................12
VNX5100/VNX5300/VNX5500 planned powerdown...................................16
Planned powerdown of your VNX5100/VNX5300/VNX5500 for
Block system.................................................................................16
Planned powerdown of VNX5300/VNX5500 for File/Unified..............19
VNX5700/VNX7500 planned powerdown....................................................25
Planned power down of your VNX5700/VNX7500 for Block
system...........................................................................................25
Planned powerdown of VNX5700/VNX7500 for File/Unified..............28
Chapter 3: Power up the VNX...............................................................35
VNX VG2 and VG8 powerup.......................................................................36
VNX5100 Block powerup............................................................................39
VNX5300 powerup......................................................................................40
VNX5300 for File/Unified powerup.....................................................41
VNX5300 Block powerup...................................................................44
VNX5500 powerup......................................................................................46
System Operations
3
Contents
VNX5500 for File/Unified powerup.....................................................46
VNX5500 Block powerup...................................................................49
VNX5700 powerup......................................................................................51
VNX5700 for File/Unified powerup.....................................................51
VNX5700 Block powerup...................................................................54
VNX7500 powerup......................................................................................56
VNX7500 for File/Unified powerup.....................................................56
VNX7500 Block powerup...................................................................59
Chapter 4: Shut down the VNX in an emergency..............................63
VNX series emergency shutdown...............................................................64
Power up after an emergency shutdown.....................................................64
Chapter 5: Halt and/or restart Control Stations and Data
Movers................................................................................................65
Halt the Control Station...............................................................................66
Halt one Control Station, locally or remotely......................................66
Halt dual Control Station, locally or remotely.....................................66
Restart the Control Station..........................................................................67
Restart one Control Station, locally or remotely.................................67
Restart two Control Station, locally or remotely.................................68
Halt and/or restart Data Movers..................................................................69
Halt the Data Movers..........................................................................69
Restart a Data Mover.........................................................................70
Chapter 6: View and manage system details....................................73
Identify the software versions......................................................................74
View Control Station software version................................................74
View Data Mover software version.....................................................74
Audit the VNX..............................................................................................74
Check the system status.............................................................................76
Change the Control Station hostname........................................................77
Install Control Station Linux security alerts.................................................79
Verify the daemons......................................................................................80
Back up the VNX database.........................................................................81
Manual VNX database backup...........................................................82
Query VNX for SCSI details .......................................................................84
Chapter 7: Manage VNX time and date settings...............................87
4
System Operations
Contents
Set the date and time of the VNX................................................................88
Set Control Station date and time......................................................88
Set Data Mover date and time............................................................88
Configure NTP service using the CLI..........................................................90
Set the time zone of the VNX......................................................................90
Change Control Station time zone manually using the CLI................90
Set Data Mover time zone manually...................................................91
Chapter 8: Manage networking ..........................................................93
Configure IPv6 on the Control Station.........................................................94
Configure SNMP.........................................................................................95
Avoid private LAN IP address conflicts........................................................96
Add DNS Server..........................................................................................96
Configure IP aliasing...................................................................................97
Create an IP alias...............................................................................98
Delete an IP alias...............................................................................99
Change VNX management port IP address values...................................100
Chapter 9: Manage logging and alerting capabilities...................101
Change the ConnectHome settings..........................................................102
Configure Connect Home.................................................................102
Provision ESRS................................................................................105
Re-provision ESRS..........................................................................107
International toll-free numbers..........................................................108
Set the country code on the MT5634ZBA modem....................................111
Manual instructions for setting the country code..............................112
Interpret log files........................................................................................116
Location of VNX logs........................................................................116
Read log messages..........................................................................117
VNX and RSA Envision.............................................................................122
NAS or SAN environment rules.................................................................123
VNX for file problem information................................................................125
Automatically collect and transfer logs.............................................125
Configuration file..............................................................................126
Enable Automatic Log Transfer from Unisphere...............................127
Run Log Collection from the CLI......................................................127
Disable Automatic Collection and Transfer tool................................128
Use CLI options to perform script operations...................................130
System Operations
5
Contents
Chapter 10: Troubleshooting..............................................................133
EMC E-Lab Interoperability Navigator.......................................................134
Error messages.........................................................................................134
Error messages for Data Mover................................................................134
EMC Training and Professional Services..................................................135
Recovery after an VNX SP failure.............................................................135
Monitor system activity..............................................................................136
System activity output...............................................................................136
Index.....................................................................................................141
6
System Operations
1
Introduction
System operations are common operation tasks that include powering up
or powering down a server, halting or restarting a Control Station or a Data
Mover or setting the server time, date, and time zone.
This document is part of the EMCé VNX㍷ Series documentation set and
is intended for use by system administrators responsible for performing
day-to-day operations of a VNX File and for monitoring the server or
resolving simple operation problems.
◆
◆
◆
◆
◆
◆
◆
System requirements on page 8
Limitations on page 8
Considerations on page 8
Cautions on page 9
User interface choices on page 9
Terminology on page 10
Related information on page 10
System Operations
7
Introduction
System requirements
Table 1 on page 8 describes the VNX software, hardware, network, and storage
configuration requirements.
Table 1. System requirements
Software
EMC VNX OE for File version 7.1
Hardware
VNX Series system
Network
No specific network requirements
Storage
No specific storage requirements
Limitations
When you change Data Mover names by using the command line interface (CLI), the new
names do not appear in the EMC Unisphere㍷ software until you refresh the browser.
The EMC VNX Operating Environment for File Release Notes and VNX Operating
Environment for Block Release Notes contain additional, late-breaking information about
VNX and its OEs.
Considerations
This document covers the operation of the following servers:
Storage type
Model name
Gateway
VNX VG2
VNX VG8
VNX for Block
VNX5100
VNX5300
VNX5500
VNX5700
VNX7500
VNX for File
VNX5300
VNX5500
VNX5700
VNX7500
8
System Operations
Introduction
Cautions
CAUTION
◆ To prevent data loss, never power down the VNX by simply turning off the red Emergency
Power Off (EPO) switch.
◆ To avoid service disruption to other clients, do not turn off the two cabinet circuit breaker
switches when the cabinet contains other equipment powered by these switches that either
services other clients or is not part of the server.
◆ EMC strongly recommends that you regularly copy the VNX database backup file from the
Control Station and save it to a remote location for safe keeping. Always copy the VNX
database backup file when hardware or software upgrades are planned.
◆ Only EMC qualified support personnel should restore the VNX database by using the VNX
database backup file.
◆ Do not manually edit the nas_db database without consulting Customer Service. Any changes
you make might disrupt services.
◆ If you use the CLI to change the Control Station hostname and use the Unisphere software
to manage the server, ensure that you follow this procedure carefully. Otherwise, file systems
cannot be created using the Unisphere software.
User interface choices
The VNX offers flexibility in managing networked storage based on interface preferences
and support environment. This document describes the system operations of the VNX by
using the CLI. You can also perform some of these tasks by using one of the VNX
management applications:
◆
EMC Unisphere software
◆
Microsoft Management Console (MMC) snap-ins
◆
Active Directory Users and Computers (ADUC) extensions
The following provide additional information about managing your VNX Unified/File:
◆
Unisphere online help
◆
Installing Management Applications on VNX for File includes instructions on launching
Unisphere software, and on installing MMC snap-ins and ADUC extensions.
Note: Unless otherwise directed, log in as nasadmin when executing CLI commands.
Cautions
9
Introduction
Terminology
The VNX Glossary provides a complete list of VNX terminology.
Related information
Specific information related to the features and functionality described in this document is
included in:
◆
EMC VNX Command Line Interface Reference for File
◆
Parameters Guide for VNX for File
◆
Online VNX for File man pages
EMC VNX Documentation on the EMC Online Support website:
The complete set of EMC VNX series customer publications is available on the EMC Online
Support website. To search for technical documentation, go to http://Support.EMC.com.
After logging in to the website, click the VNX Support by Product page to locate information
for the specific feature required.
VNX wizards:
Unisphere software provides wizards for performing setup and configuration tasks. The
Unisphere online help provides more details on the wizards.
10
System Operations
2
Planned powerdown of the
VNX
You should perform a planned power down to remove power from the VNX
in an orderly way to protect data.
CAUTION Incorrectly powering down the VNX can cause data loss or service
disruption.
Note: For instructions on powering up a DC-powered VNX, refer to the EMC
DC-Powered VNX Series Enclosures Installation and Operation Guide (P/N:
300-012-880) for instructions.
◆
◆
◆
Planned powerdown of VNX VG2/VNX VG8 Gateway system on
page 12
VNX5100/VNX5300/VNX5500 planned powerdown on page 16
VNX5700/VNX7500 planned powerdown on page 25
System Operations
11
Planned powerdown of the VNX
Planned powerdown of VNX VG2/VNX VG8 Gateway system
Before you begin
Before powering down your VNX Gateway system, EMC recommends that you know the
Operating Environment (OE) version on your VNX Gateway, as the power down process
differs between certain OE versions. Ensure that you perform the steps required for your
OE version.
Procedure
To perform a complete planned power down of your VNX system:
1. When possible, before you power down the system:
a. Notify all users of the planned powerdown several days in advance when possible.
b. Prevent all logins and notify all users several minutes in advance of the impending
powerdown.
c. Log out all users.
Note: At times in this procedure you will be directed to view status (power and/or fault) LEDs on
certain system components. For an unobstructed view of component status LEDs, be prepared to
remove protective front bezels and/or access the rear of the system. Reattach all front bezels when
the power down is complete.
2. Log into Unisphere on the primary Control Station of the system being powered down
and check the system status.
a. From a browser, type the IP address of the primary Control Station.
b. Log in to the Unisphere software as Root and define the scope as Local.
c. On the Unisphere Dashboard locate the Systems by Severity quadrant.
d. Verify that the Status fields for the VNX system to be powered down shows no current
Critical alerts.
e. Optionally, confirm the status of the Control Station and Data Mover components by
selecting the <VNX_system> ➤ System ➤ Run Command option in Unisphere under
Control Station CLI on the right-hand side of the page:
/nasmcd/sbin/getreason
Expected Reason Code values for booted VNX with a single Control Station and two
Data Movers:
10 - slot_0 primary control station
5 - slot_2 contacted
5 - slot_3 contacted
12
System Operations
Planned powerdown of the VNX
3. [VNX OE for File version 7.1.74.5] Power off the VNX Gateway Control Station(s) and
Data Movers using the Unisphere power off button.
Note: VNX systems on VNX OE for File version 7.1.72.1 or below do not present a power off button.
Follow the instructions in Step 4 to power down your VNX system.
a. Select System List from the top navigation bar.
Note: If System List is not shown in the navigation bar, select All Systems in the system list drop-down
menu.
b. Select the system to be powered down from the system list.
c. Click the Power Off button and follow the prompts that appear as you power off the
system.
Note: If you experience any issues or uncertainties during this planned powerdown activity,
contact you authorized support provider. Do NOT remove external power from the VNX until
you resolve the situation.
Ensure that you read and follow the recommendations that appear in Unisphere as
you power off the VNX system.
You have powered off the VNX Gateway system. Continue to Step 5 to complete the
planned power down activity.
4. [VNX OE for File version 7.1.72.1 or below] Power down the VNX Gateway Control
Station(s) and Data Movers using Control Station CLI.
a. Use Unisphere Control Station CLI to halt the Control Stations and the Data Movers:
/nasmcd/sbin/nas_halt now
The following warning message will appear prompted for your confirmation to continue.
*************************** WARNING! **************************
You are about to HALT this VNX including all of its Control
Stations and Data Movers. DATA will be UNAVAILABLE when the system
is halted.
Note that this command does *not* halt the storage array.
ARE YOU SURE YOU WANT TO CONTINUE? [ yes or no ] :
b. At the warning prompt, type yes to initiate the power down process for the system's
Control Stations and Data Movers.
You will see details about the progress of the power down process for these
components displayed in the command output.
Planned powerdown of VNX VG2/VNX VG8 Gateway system
13
Planned powerdown of the VNX
Note: It can take from 5 minutes to 20 minutes to halt the server, depending on the system
configuration. Do not continue until this command completes.
All Control Stations and Data Movers are successfully powered down when the terminal
emulator session is unresponsive and a prompt similar to the one below appears:
May 10 11:35:08 rtpplat32cs0 exiting on signal 15
5. If you want to power down the storage array, follow the powerdown instructions in the
array documentation, at this time.
6. Follow the steps below to completely remove power from each Data Mover enclosure
and Control Station.
a. Check each Data Mover enclosure (DME) power and fault LEDs.
CPU power LED
Power supply/cooling
(fan) LED
AC
Enclosure
fault LED
CPU fault LED
Enclosure
power LED
AC
CPU unsafe to
remove LED
AC
AC
VNX-SK-001668
On the front of a successfully powered down DME, the enclosure amber fault LED is
lit and the enclosure power LED is not lit.
Additionally, on the rear of a successfully powered down DME, the amber fault LED
is lit on the latch handle of each DME management module.
b. After verifying the successful power down of each DME, disconnect all DME power
cables from the PDUs. There are two power cables per DME.
c. Check the front LEDs of each Control Station.
14
System Operations
Planned powerdown of the VNX
Note: The front bezel must be removed to for a clear view of the CS LEDs.
Only the networking indication LED (number 6 in the illustration) may be lit on a
successfully powered down Control Station. All other LEDs on the front of the Control
Station are off.
d. After verifying the successful power down of each CS, disconnect the power cords
for CS 0 and CS 1, if present, from the PDUs.
7. Does the VNX Gateway server cabinet contain other equipment that is connected to the
cabinet PDPs and shared with other systems (such as Fibre Channel switches, storage
arrays, and so forth)?
◆
If yes, stop here. The VNX Gateway server is powered down.
◆
If no, go to the next step.
8. Turn off (0 position) the left and right cabinet circuit-breaker switches located at the back
of the cabinet near the bottom to complete the powerdown of the server.
Note: If the server is installed in a non-EMC cabinet, the switches are probably in a different location.
Planned powerdown of VNX VG2/VNX VG8 Gateway system
15
Planned powerdown of the VNX
CAUTION To avoid service disruption to other clients, do not turn off the two cabinet circuit
breaker switches when the cabinet contains other equipment powered by these switches
that either services other clients or is not part of the VNX Gateway server.
VNX5100/VNX5300/VNX5500 planned powerdown
Follow the powerdown instructions for your system configuration.
The VNX5100 is available in one configuration: Block. The VNX5300 and VNX5500 are
available in three configurations: Block, File, and Unified.
◆
Planned powerdown of your VNX5100/VNX5300/VNX5500 for Block system on page
16
◆
Planned powerdown of VNX5300/VNX5500 for File/Unified on page 19
Planned powerdown of your VNX5100/VNX5300/VNX5500 for Block system
Before you begin
Before powering down your VNX for Block system, EMC recommends that you know the
Operating Environment (OE) version on your VNX for Block, as the power down process
differs between certain OE versions. Ensure that you perform the steps required for your
OE version.
Procedure
16
System Operations
Planned powerdown of the VNX
To perform a complete planned power down of your VNX system:
1. When possible, before you power down the system:
a. Notify all users of the planned powerdown several days in advance when possible.
b. Prevent all logins and notify all users several minutes in advance of the impending
powerdown.
c. Log out all users.
Note: At times in this procedure you will be directed to view status (power and/or fault) LEDs on
certain system components. For an unobstructed view of component status LEDs, be prepared to
remove protective front bezels and/or access the rear of the system. Reattach all front bezels when
the power down is complete.
2. Log into Unisphere on one of the storage processors of the system being powered down
and check the system status.
a. From a browser, type the IP address of a storage processor.
b. Log in to the Unisphere software as sysadmin and define the scope as Global.
c. On the Unisphere Dashboard locate the Systems by Severity quadrant.
d. Verify that the Status fields for the VNX system to be powered down shows no current
Critical alerts.
3. [VNX OE for Block version 05.32.000.5.209 or higher] Power off the VNX for Block storage
processors using the Unisphere power off button.
Note: VNX systems on VNX OE for Block version 05.32.000.5.207 or below do not present a power
off button. Follow the instructions in Step 4 to power down your VNX system.
a. Select System List from the top navigation bar.
Note: If System List is not shown in the navigation bar, select All Systems in the system list drop-down
menu.
b. Select the system to be powered down from the system list.
c. Click the Power Off button and follow the prompts that appear as you power off the
system.
Note: If you experience any issues or uncertainties during this planned powerdown activity,
contact you authorized support provider. Do NOT remove external power from the VNX until
you resolve the situation.
VNX5100/VNX5300/VNX5500 planned powerdown
17
Planned powerdown of the VNX
Ensure that you read and follow the recommendations that appear in Unisphere as
you power off the VNX system.
d. Verify disk processor enclosure (DPE) and storage processor (SP) LEDs to confirm
power off status.
On the rear of a successfully powered down DPE, the SP blue power LED, SP amber
fault LED, and Unsafe to remove (white hand symbol) LED are OFF on each storage
processor.
Additionally, on the front of a successfully powered down DPE, the DPE enclosure
power/status blue LED is ON and all other DPE and disk module LEDs are OFF.
After verifying the status of these DPE and SP LEDs, continue to the next step.
e. Turn the SPS switches to the off position (0 position):
f. For systems with a single SPS, after waiting two minutes, unplug the SP B power
cable from the PDU.
You have powered off the VNX system. Go to Step 5 and continue the planned power
down activity.
4. [VNX OE for Block version 05.32.000.5.207 or below] Power down the VNX for Block
storage processors using the power switches on the SPS.
a. Stop all I/O activity to the storage processors, which includes all I/O activity from any
external hosts attached to the storage processors and then wait 5 minutes.
18
System Operations
Planned powerdown of the VNX
Stopping I/O allows the SP to destage cache data, and may take some time. The
length of time depends on criteria such as the size of the cache, the amount of data
in the cache, the type of data in the cache, and the target location on the disks, but
it is typically less than one minute.
b. Turn the SPS switches to the off position (0 position):
c. Wait two minutes to allow the storage system to write its cache to disk.
d. Ensure that the SPS LEDs are off before continuing, which indicates that the cached
data has been saved to the vault disks and that the SPS units are powered off and
have removed power from connect components.
e. For systems with a single SPS, after waiting two minutes, unplug the SP B power
cable from the PDU.
You have powered off the VNX system. Go to Step 5 and continue the planned power
down activity.
5. If there are additional optional DAEs and you intend to power off the entire array,
disconnect the power cables from each DAE to the PDUs. This powers down the DAEs.
Planned powerdown of VNX5300/VNX5500 for File/Unified
Before you begin
Before powering down your VNX for File/Unified system, EMC recommends that you know
the Operating Environment (OE) version on your VNX for File/Unified, as the power down
process differs between certain OE versions. Ensure that you perform the steps required
for your OE version.
Procedure
To perform a complete planned power down of your VNX system:
1. When possible, before you power down the system:
a. Notify all users of the planned powerdown several days in advance when possible.
VNX5100/VNX5300/VNX5500 planned powerdown
19
Planned powerdown of the VNX
b. Prevent all logins and notify all users several minutes in advance of the impending
powerdown.
c. Log out all users.
Note: At times in this procedure you will be directed to view status (power and/or fault) LEDs on
certain system components. For an unobstructed view of component status LEDs, be prepared to
remove protective front bezels and/or access the rear of the system. Reattach all front bezels when
the power down is complete.
2. Log into Unisphere on the primary Control Station of the system being powered down
and check the system status.
a. From a browser, type the IP address of the primary Control Station.
b. Log in to the Unisphere software as sysadmin and define the scope as Global.
c. On the Unisphere Dashboard locate the Systems by Severity quadrant.
d. Verify that the Status fields for the VNX system to be powered down shows no current
Critical alerts.
e. Optionally, confirm the status of the Control Station and Data Mover components by
selecting the <VNX_system> ➤ System ➤ Run Command option in Unisphere under
Control Station CLI on the right-hand side of the page:
/nasmcd/sbin/getreason
Expected Reason Code values for booted VNX with a single Control Station and two
Data Movers:
10 - slot_0 primary control station
5 - slot_2 contacted
5 - slot_3 contacted
3. [VNX OE for File version 7.1.74.5/VNX OE for Block version 05.32.000.5.209 or higher]
Power off the VNX for File Control Station(s), Data Movers, and storage processors using
the Unisphere power off button.
Note: VNX systems on VNX OE for File version 7.1.72.1/VNX OE for Block version 05.32.000.5.207
or below do not present a power off button. Follow the instructions in Step 4 to power down your
VNX system.
a. Select System List from the top navigation bar.
Note: If System List is not shown in the navigation bar, select All Systems in the system list drop-down
menu.
20
System Operations
Planned powerdown of the VNX
b. Select the system to be powered down from the system list.
c. Click the Power Off button and follow the prompts that appear as you power off the
system.
Note: If you experience any issues or uncertainties during this planned powerdown activity,
contact you authorized support provider. Do NOT remove external power from the VNX until
you resolve the situation.
Ensure that you read and follow the recommendations that appear in Unisphere as
you power off the VNX system.
d. Verify disk processor enclosure (DPE) and storage processor (SP) LEDs to confirm
power off status.
On the rear of a successfully powered down DPE, the SP blue power LED, SP amber
fault LED, and Unsafe to remove (white hand symbol) LED are OFF on each storage
processor.
Additionally, on the front of a successfully powered down DPE, the DPE enclosure
power/status blue LED is ON and all other DPE and disk module LEDs are OFF.
After verifying the status of these DPE and SP LEDs, continue to the next step.
e. Turn the SPS switches to the off position (0 position):
VNX5100/VNX5300/VNX5500 planned powerdown
21
Planned powerdown of the VNX
f. For systems with a single SPS, after waiting two minutes, unplug the SP B power
cable from the PDU.
You have powered off the VNX system. Continue to Step 5 to complete the planned
power down activity.
4. [VNX OE for File version 7.1.72.1/VNX OE for Block version 05.32.000.5.207 or below]
Power down the VNX for File.
In this step, you will use Control Station CLI to power down the Control Station(s) and
Data Movers and the power switches on the SPS to power down the storage processors.
a. Use Unisphere Control Station CLI to halt the Control Stations and the Data Movers:
/nasmcd/sbin/nas_halt now
The following warning message will appear prompted for your confirmation to continue.
*************************** WARNING! **************************
You are about to HALT this VNX including all of its Control
Stations and Data Movers. DATA will be UNAVAILABLE when the system
is halted.
Note that this command does *not* halt the storage array.
ARE YOU SURE YOU WANT TO CONTINUE? [ yes or no ] :
b. At the warning prompt, type yes to initiate the power down process for the system's
Control Stations and Data Movers.
You will see details about the progress of the power down process for these
components displayed in the command output.
Note: It can take from 5 minutes to 20 minutes to halt the server, depending on the system
configuration. Do not continue until this command completes.
All Control Stations and Data Movers are successfully powered down when the terminal
emulator session is unresponsive and a prompt similar to the one below appears:
May 10 11:35:08 rtpplat32cs0 exiting on signal 15
c. Determine your next step:
◆
If you do not wish to power down the system completely, skip the remaining
alpha-numbered steps and go to Step 5 and continue the planned power down
activity.
◆
If you do wish to power down the system completely, continue with the next
alpha-numbered step to power down the storage processors and vault drives.
Note: All I/O activity flowing from the Data Movers was stopped when the Data Movers were
shutdown upon issuing /nas_halt now.
22
System Operations
Planned powerdown of the VNX
d. Stop all I/O activity to the storage processors, which includes all I/O activity from any
external hosts attached to the storage processors and then wait 5 minutes.
Stopping I/O allows the SP to destage cache data, and may take some time. The
length of time depends on criteria such as the size of the cache, the amount of data
in the cache, the type of data in the cache, and the target location on the disks, but
it is typically less than one minute.
e. Turn the SPS switches to the off position (0 position):
f. Wait two minutes to allow the storage system to write its cache to disk.
g. Ensure that the SPS LEDs are off before continuing, which indicates that the cached
data has been saved to the vault disks and that the SPS units are powered off and
have removed power from connect components.
h. For systems with a single SPS, after waiting two minutes, unplug the SP B power
cable from the PDU.
You have powered off the VNX system. Continue to Step 5 to complete the planned
power down activity.
5. Follow the steps below to completely remove power from each Data Mover enclosure
and Control Station.
a. Check each Data Mover enclosure (DME) power and fault LEDs.
CPU power LED
Power supply/cooling
(fan) LED
AC
Enclosure
fault LED
CPU fault LED
Enclosure
power LED
AC
CPU unsafe to
remove LED
AC
AC
VNX-SK-001668
VNX5100/VNX5300/VNX5500 planned powerdown
23
Planned powerdown of the VNX
On the front of a successfully powered down DME, the enclosure amber fault LED is
lit and the enclosure power LED is not lit.
Additionally, on the rear of a successfully powered down DME, the amber fault LED
is lit on the latch handle of each DME management module.
b. After verifying the successful power down of each DME, disconnect all DME power
cables from the PDUs. There are two power cables per DME.
c. Check the front LEDs of each Control Station.
Note: The front bezel must be removed to for a clear view of the CS LEDs.
Only the networking indication LED (number 6 in the illustration) may be lit on a
successfully powered down Control Station. All other LEDs on the front of the Control
Station are off.
d. After verifying the successful power down of each CS, disconnect the power cords
for CS 0 and CS 1, if present, from the PDUs.
6. If there are additional optional DAEs and you intend to power off the entire array,
disconnect the power cables from each DAE to the PDUs. This powers down the DAEs.
24
System Operations
Planned powerdown of the VNX
VNX5700/VNX7500 planned powerdown
Follow the powerdown instructions for your system configuration.
The VNX5700 and VNX7500 are available in three configurations: Block, File, and Unified.
◆
Planned power down of your VNX5700/VNX7500 for Block system on page 25
◆
Planned powerdown of VNX5700/VNX7500 for File/Unified on page 28
Planned power down of your VNX5700/VNX7500 for Block system
Before you begin
Before powering down your VNX for Block system, EMC recommends that you know the
Operating Environment (OE) version on your VNX for Block, as the power down process
differs between certain OE versions. Ensure that you perform the steps required for your
OE version.
Procedure
To perform a complete planned power down of your VNX system:
1. When possible, before you power down the system:
a. Notify all users of the planned powerdown several days in advance when possible.
b. Prevent all logins and notify all users several minutes in advance of the impending
powerdown.
c. Log out all users.
Note: At times in this procedure you will be directed to view status (power and/or fault) LEDs on
certain system components. For an unobstructed view of component status LEDs, be prepared to
remove protective front bezels and/or access the rear of the system. Reattach all front bezels when
the power down is complete.
2. Log into Unisphere on one of the storage processors of the system being powered down
and check the system status.
a. From a browser, type the IP address of a storage processor.
b. Log in to the Unisphere software as sysadmin and define the scope as Global.
c. On the Unisphere Dashboard locate the Systems by Severity quadrant.
d. Verify that the Status fields for the VNX system to be powered down shows no current
Critical alerts.
VNX5700/VNX7500 planned powerdown
25
Planned powerdown of the VNX
3. [VNX OE for Block version 05.32.000.5.209 or higher] Power off the VNX for Block storage
processors using the Unisphere power off button.
Note: VNX systems on VNX OE for Block version 05.32.000.5.207 or below do not present a power
off button. Follow the instructions in Step 4 to power down your VNX system.
a. Select System List from the top navigation bar.
Note: If System List is not shown in the navigation bar, select All Systems in the system list drop-down
menu.
b. Select the system to be powered down from the system list.
c. Click the Power Off button and follow the prompts that appear as you power off the
system.
Note: If you experience any issues or uncertainties during this planned powerdown activity,
contact you authorized support provider. Do NOT remove external power from the VNX until
you resolve the situation.
Ensure that you read and follow the recommendations that appear in Unisphere as
you power off the VNX system.
d. Verify storage processor enclosure (SPE) and storage processor LEDs to confirm
power off status.
CPU power LED
Power supply/cooling
(fan) LED
AC
Enclosure
fault LED
CPU fault LED
Enclosure
power LED
AC
CPU unsafe to
remove LED
AC
AC
VNX-SK-001668
On the front of a successfully powered down SPE, each power supply/cooling module
amber fault LED is ON and all other SP and SPE LEDs are OFF.
Additionally, on the rear of a successfully powered down SPE, all power, status, and
fault LEDs on each SP are OFF.
26
System Operations
Planned powerdown of the VNX
After verifying the status of these SPE and SP LEDs, continue to the next step.
e. Turn the SPS switches to the off position (0 position):
4. [VNX OE for Block version 05.32.000.5.207 or below] Power down the VNX for Block
storage processors and vault DAE (DAE0_0) using the power switches on the SPS.
a. Stop all I/O activity to the storage processors, which includes all I/O activity from any
external hosts attached to the storage processors and then wait 5 minutes.
Stopping I/O allows the SP to destage cache data, and may take some time. The
length of time depends on criteria such as the size of the cache, the amount of data
in the cache, the type of data in the cache, and the target location on the disks, but
it is typically less than one minute.
b. Turn the SPS switches to the off position (0 position):
c. Wait two minutes to allow the storage system to write its cache to disk.
d. Ensure that the SPS LEDs are off before continuing, which indicates that the cached
data has been saved to the vault disks and that the SPS units are powered off and
have removed power from connect components.
5. If there are additional optional DAEs and you intend to power off the entire array,
disconnect the power cables from each DAE to the PDUs. This powers down the DAEs.
VNX5700/VNX7500 planned powerdown
27
Planned powerdown of the VNX
Planned powerdown of VNX5700/VNX7500 for File/Unified
Before you begin
Before powering down your VNX for File/Unified system, EMC recommends that you know
the Operating Environment (OE) version on your VNX for File/Unified, as the power down
process differs between certain OE versions. Ensure that you perform the steps required
for your OE version.
Procedure
To perform a complete planned power down of your VNX system:
1. When possible, before you power down the system:
a. Notify all users of the planned powerdown several days in advance when possible.
b. Prevent all logins and notify all users several minutes in advance of the impending
powerdown.
c. Log out all users.
Note: At times in this procedure you will be directed to view status (power and/or fault) LEDs on
certain system components. For an unobstructed view of component status LEDs, be prepared to
remove protective front bezels and/or access the rear of the system. Reattach all front bezels when
the power down is complete.
2. Log into Unisphere on the primary Control Station of the system being powered down
and check the system status.
a. From a browser, type the IP address of the primary Control Station.
b. Log in to the Unisphere software as sysadmin and define the scope as Global.
c. On the Unisphere Dashboard locate the Systems by Severity quadrant.
d. Verify that the Status fields for the VNX system to be powered down shows no current
Critical alerts.
e. Optionally, confirm the status of the Control Station and Data Mover components by
selecting the <VNX_system> ➤ System ➤ Run Command option in Unisphere under
Control Station CLI on the right-hand side of the page:
/nasmcd/sbin/getreason
Expected Reason Code values for booted VNX with a single Control Station and two
Data Movers:
10 - slot_0 primary control station
5 - slot_2 contacted
5 - slot_3 contacted
28
System Operations
Planned powerdown of the VNX
3. [VNX OE for File version 7.1.74.5/VNX OE for Block version 05.32.000.5.209 or higher]
Power off the VNX for File Control Station(s), Data Movers, and storage processors using
the Unisphere power off button.
Note: VNX systems on VNX OE for File version 7.1.72.1/VNX OE for Block version 05.32.000.5.207
or below do not present a power off button. Follow the instructions in Step 4 to power down your
VNX system.
Note: VNX systems operating with OE versions below those listed do not present a power off
button. Follow the instructions in ___ to power down your VNX system.
a. Select System List from the top navigation bar.
Note: If System List is not shown in the navigation bar, select All Systems in the system list drop-down
menu.
b. Select the system to be powered down from the system list.
c. Click the Power Off button and follow the prompts that appear as you power off the
system.
Note: If you experience any issues or uncertainties during this planned powerdown activity,
contact you authorized support provider. Do NOT remove external power from the VNX until
you resolve the situation.
Ensure that you read and follow the recommendations that appear in Unisphere as
you power off the VNX system.
d. Verify storage processor enclosure (SPE) and storage processor LEDs to confirm
power off status.
CPU power LED
Power supply/cooling
(fan) LED
AC
Enclosure
fault LED
CPU fault LED
Enclosure
power LED
AC
CPU unsafe to
remove LED
AC
AC
VNX-SK-001668
VNX5700/VNX7500 planned powerdown
29
Planned powerdown of the VNX
On the front of a successfully powered down SPE, each power supply/cooling module
amber fault LED is ON and all other SP and SPE LEDs are OFF.
Additionally, on the rear of a successfully powered down SPE, all power, status, and
fault LEDs on each SP are OFF.
After verifying the status of these SPE and SP LEDs, continue to the next step.
e. Turn the SPS switches to the off position (0 position):
You have powered off the VNX system. Go to Step 5 and continue the planned power
down activity.
4. [VNX OE for File version 7.1.72.1/VNX OE for Block version 05.32.000.5.207 or below]
Power down the VNX for File.
In this step, you will use Control Station CLI to power down the Control Station(s) and
Data Movers and the power switches on the SPS to power down the storage processors
and vault DAE (DAE0_0).
a. Use Unisphere Control Station CLI to halt the Control Stations and the Data Movers:
/nasmcd/sbin/nas_halt now
The following warning message will appear prompted for your confirmation to continue.
*************************** WARNING! **************************
You are about to HALT this VNX including all of its Control
Stations and Data Movers. DATA will be UNAVAILABLE when the system
is halted.
Note that this command does *not* halt the storage array.
ARE YOU SURE YOU WANT TO CONTINUE? [ yes or no ] :
b. At the warning prompt, type yes to initiate the power down process for the system's
Control Stations and Data Movers.
You will see details about the progress of the power down process for these
components displayed in the command output.
Note: It can take from 5 minutes to 20 minutes to halt the server, depending on the system
configuration. Do not continue until this command completes.
30
System Operations
Planned powerdown of the VNX
All Control Stations and Data Movers are successfully powered down when the terminal
emulator session is unresponsive and a prompt similar to the one below appears:
May 10 11:35:08 rtpplat32cs0 exiting on signal 15
c. Determine your next step:
◆
If you do not wish to power down the system completely, skip the remaining
alpha-numbered steps and go to Step 5 and continue the planned power down
activity.
◆
If you do wish to power down the system completely, continue with the next
alpha-numbered step to power down the storage processors and vault drives.
Note: All I/O activity flowing from the Data Movers was stopped when the Data Movers were
shutdown upon issuing /nas_halt now.
d. Stop all I/O activity to the storage processors, which includes all I/O activity from any
external hosts attached to the storage processors and then wait 5 minutes.
Stopping I/O allows the SP to destage cache data, and may take some time. The
length of time depends on criteria such as the size of the cache, the amount of data
in the cache, the type of data in the cache, and the target location on the disks, but
it is typically less than one minute.
e. Turn the SPS switches to the off position (0 position):
f. Wait two minutes to allow the storage system to write its cache to disk.
g. Ensure that the SPS LEDs are off before continuing, which indicates that the cached
data has been saved to the vault disks and that the SPS units are powered off and
have removed power from connect components.
You have powered off the VNX system. Go to Step 5 and continue the planned power
down activity.
5. Follow the steps below to completely remove power from each Data Mover enclosure
and Control Station.
VNX5700/VNX7500 planned powerdown
31
Planned powerdown of the VNX
a. Check each Data Mover enclosure (DME) power and fault LEDs.
CPU power LED
Power supply/cooling
(fan) LED
AC
Enclosure
fault LED
CPU fault LED
Enclosure
power LED
AC
CPU unsafe to
remove LED
AC
AC
VNX-SK-001668
On the front of a successfully powered down DME, the enclosure amber fault LED is
lit and the enclosure power LED is not lit.
Additionally, on the rear of a successfully powered down DME, the amber fault LED
is lit on the latch handle of each DME management module.
b. After verifying the successful power down of each DME, disconnect all DME power
cables from the PDUs. There are two power cables per DME.
c. Check the front LEDs of each Control Station.
32
System Operations
Planned powerdown of the VNX
Note: The front bezel must be removed to for a clear view of the CS LEDs.
Only the networking indication LED (number 6 in the illustration) may be lit on a
successfully powered down Control Station. All other LEDs on the front of the Control
Station are off.
d. After verifying the successful power down of each CS, disconnect the power cords
for CS 0 and CS 1, if present, from the PDUs.
6. If there are additional optional DAEs and you intend to power off the entire array,
disconnect the power cables from each DAE to the PDUs. This powers down the DAEs.
VNX5700/VNX7500 planned powerdown
33
Planned powerdown of the VNX
34
System Operations
3
Power up the VNX
Follow the appropriate task below to power up the VNX after a planned
power down or after an emergency shutdown:
Note: For instructions on powering up a DC-powered VNX, refer to the EMC
DC-Powered VNX Series Enclosures Installation and Operation Guide (P/N:
300-012-880) for instructions.
◆
◆
◆
◆
◆
◆
VNX VG2 and VG8 powerup on page 36
VNX5100 Block powerup on page 39
VNX5300 powerup on page 40
VNX5500 powerup on page 46
VNX5700 powerup on page 51
VNX7500 powerup on page 56
System Operations
35
Power up the VNX
VNX VG2 and VG8 powerup
The VG2 can be configured with either one or two Data Movers and one or two Control
Stations.
The VG8 has either two to eight Data Movers and one or two Control Stations. These
instructions cover all configurations.
1. If the VNX Gateway is in a cabinet by itself (that is, the storage array is not in the same
cabinet), then turn off the cabinet circuit-breakers to remove all power from the cabinet.
2. Ensure that the power cables for the Data Mover enclosures (two cables per enclosure)
and Control Stations (one cable per CS) are not connected to the PDUs.You will connect
these power cables later.
3. Turn on (I position) the left and right cabinet circuit-breaker switches at the back of the
cabinet near the bottom.
If the server is installed in a cabinet not manufactured by EMC, the circuit-breaker switches
might be in a different location.
4. If the boot storage array is off, power it up. Follow the instructions in the array
documentation.
5. Connect all Data Mover enclosure power cables to the PDUs in a manner ensuring high
availability and wait for the Data Movers to power up. The blue power LED on the front
of the Data Mover enclosure will light when the Data Movers have powered up.
6. Wait 4-5 minutes as the Data Movers power up to ensure that the Data Movers have
booted and that they are ready. Then, connect the power cable for the Control Station 0
to the PDU.
Important: Do not plug in the power cable for CS 1, if present, at this time. CS 1 will be booted later
in this process.
7. Check the CS power LED (3 in the following figure) on the front of the Control Station
verify that the CS is booting. This green LED will blink as the CS boots and be on when
complete.
36
System Operations
Power up the VNX
Note: The front bezel must be removed to for a clear view of the CS LEDs and to access the power
button of the Control Station.
If, after 5 minutes, this LED indicates that the Control Station is off, turn on the Control
Station by pressing the power button (1) on the front.
Ensure that the Control Station is powered up before continuing.
8. Check the system and hardware status as follows:
a. From a browser, type the IP address of the primary Control Station.
b. Log in to the Unisphere software as sysadmin and define the scope as Global.
c. Use the drop-down list at the topleft Dashboard to select the system name and view
its System Information.
d. On this page, verify that the Status fields for the VNX display OK.
e. Next, locate the Run Command option in Unisphere under Control Station CLI on the
righthand side of the System page and verify that CS 0 and the Data Movers booted
successfully by running a Control Station CLI command:
/nasmcd/sbin/getreason
Expected Reason Code values for booted VNX for File components:
10 - slot_0 primary control station
5 - slot_2 contacted
5 - slot_3 contacted
VNX VG2 and VG8 powerup
37
Power up the VNX
9. For dual Control Station systems only, once you have confirmed that CS 0 is up and
healthy, power up CS 1 by connecting the power cable for the CS 1 to a PDU on a different
circuit from CS 0 to ensure high availability.
10. After completing the power up of the system, return to the Run Command option in
Unisphere and perform a system checkup:
nas_checkup
Fix issues discovered by the nas_checkup command in the manner indicated in its output.
38
System Operations
Power up the VNX
VNX5100 Block powerup
Follow the instructions below for your VNX5100 for Block:
1. Verify that the master switch/circuit breakers for each cabinet power strip are OFF.
2. Verify that the power switches on SPS A and SPS B are in the OFF position.
3. Ensure that the power cable for SP A is plugged into SPS A and the power cable retention
bails are in place.
4. In a system with one SPS, ensure that the power cable for SP B is plugged into the
nearest power distribution unit (PDU) on a different circuit from SPS A and that the power
cable retention bails are in place.
In a system with two SPSs, ensure that the power cable for SP B is plugged into SPS B
and the power cable retention bails are in place.
5. Verify that the following sense cable serial connections are in place:
◆
SP A to SPS A
◆
SP B to SPS B
6. Verify that the power cables for the SPSs are plugged into the appropriate cabinet power
strips on either side of the rack in a manner ensuring high availability and the power cable
retention bails are in place.
7. Verify that the power cables for any additional DAEs are plugged into the appropriate
cabinet power strips on either side of the rack in a manner ensuring high availability and
the power cable retention bails are in place.
8. Turn the SPS power switches ON.
9. Ensure that any other devices in the cabinet are correctly installed and ready for power
up.
VNX5100 Block powerup
39
Power up the VNX
10. Turn on the master switch/circuit breakers for each cabinet power strip.
In a 40U EMC cabinet, the master switches are on the power distribution panels (PDPs).
The storage system can take 10-12 minutes to complete a typical power up. Amber
warning LEDs flash during the power on self-test (POST) and then go off. The front fault
LED and the SPS recharge LEDs commonly stay on for several minutes while the SPSs
are charging.
11. You have completed the powerup of the system when the SP power LED on each SP is
steady green.
If amber LEDs on the front or back of the storage system remain on for more than 10
minutes, ensure that the system is correctly cabled, and then refer to the Troubleshooting
Trees on the EMC Support page for the storage system. If you cannot determine any
reasons for the fault, contact your authorized service provider.
VNX5300 powerup
The VNX5300 is available in three configurations: Block, File, and Unified. Follow the
instructions for your system configuration.
40
◆
VNX5300 for File/Unified powerup on page 41
◆
VNX5300 Block powerup on page 44
System Operations
Power up the VNX
VNX5300 for File/Unified powerup
The VNX5300 for File and VNX5300 Unified can be configured with either one or two Data
Movers and one or two Control Stations.
1. Verify that the master switch/circuit breakers for each cabinet power strip are ON.
2. Verify that the power switches on SPS A and SPS B are in the OFF position.
3. Ensure that the power cables for the Data Mover enclosures (two cables per enclosure)
and Control Stations (one cable per CS) are not connected to the PDUs.You will connect
these power cables later.
4. Ensure that the power cable for SP A is plugged into SPS A and the power cable retention
bails are in place.
5. In a system with one SPS, ensure that the power cable for SP B is plugged into the
nearest power distribution unit (PDU) on a different circuit from SPS A and that the power
cable retention bails are in place.
In a system with two SPSs, ensure that the power cable for SP B is plugged into SPS B
and the power cable retention bails are in place.
6. Verify that the following sense cable serial connections are in place:
◆
SP A to SPS A
◆
SP B to SPS B
7. Verify that the power cables for the SPSs are plugged into the appropriate cabinet power
strips on either side of the rack in a manner ensuring high availability and the power cable
retention bails are in place.
8. Verify that the power cables for any additional DAEs are plugged into the appropriate
cabinet power strips on either side of the rack in a manner ensuring high availability and
the power cable retention bails are in place.
VNX5300 powerup
41
Power up the VNX
9. Turn the SPS power switches ON.
10. Connect all Data Mover enclosure power cables to the PDUs in a manner ensuring high
availability and wait for the Data Movers to power up. The blue power LED on the front
of the Data Mover enclosure will light when the Data Movers have powered up.
11. Wait 4-5 minutes as the Data Movers power up to ensure that the Data Movers have
booted and that they are ready. Then, connect the power cable for the Control Station 0
to the PDU.
Important: Do not plug in the power cable for CS 1, if present, at this time. CS 1 will be booted later
in this process.
12. Check the CS power LED (3 in the following figure) on the front of the Control Station
verify that the CS is booting. This green LED will blink as the CS boots and be on when
complete.
Note: The front bezel must be removed to for a clear view of the CS LEDs and to access the power
button of the Control Station.
If, after 5 minutes, this LED indicates that the Control Station is off, turn on the Control
Station by pressing the power button (1) on the front.
Ensure that the Control Station is powered up before continuing.
42
System Operations
Power up the VNX
13. Check the system and hardware status as follows:
a. From a browser, type the IP address of the primary Control Station.
b. Log in to the Unisphere software as sysadmin and define the scope as Global.
c. Use the drop-down list at the topleft Dashboard to select the system name and view
its System Information.
d. On this page, verify that the Status fields for the VNX display OK.
e. Next, locate the Run Command option in Unisphere under Control Station CLI on the
righthand side of the System page and verify that CS 0 and the Data Movers booted
successfully by running a Control Station CLI command:
/nasmcd/sbin/getreason
Expected Reason Code values for booted VNX for File components:
10 - slot_0 primary control station
5 - slot_2 contacted
5 - slot_3 contacted
14. For dual Control Station systems only, once you have confirmed that CS 0 is up and
healthy, power up CS 1 by connecting the power cable for the CS 1 to a PDU on a different
circuit from CS 0 to ensure high availability.
15. You have completed the powerup of the system when the SP power LED on each SP is
steady green.
If amber LEDs on the front or back of the storage system remain on for more than 10
minutes, ensure that the system is correctly cabled, and then refer to the Troubleshooting
VNX5300 powerup
43
Power up the VNX
Trees on the EMC Support page for the storage system. If you cannot determine any
reasons for the fault, contact your authorized service provider.
16. After completing the power up of the system, return to the Run Command option in
Unisphere and perform a system checkup:
nas_checkup
Fix issues discovered by the nas_checkup command in the manner indicated in its output.
VNX5300 Block powerup
Follow the instructions below for your VNX5300 for Block:
1. Verify that the master switch/circuit breakers for each cabinet power strip are OFF.
2. Verify that the power switches on SPS A and SPS B are in the OFF position.
3. Ensure that the power cable for SP A is plugged into SPS A and the power cable retention
bails are in place.
4. In a system with one SPS, ensure that the power cable for SP B is plugged into the
nearest power distribution unit (PDU) on a different circuit from SPS A and that the power
cable retention bails are in place.
In a system with two SPSs, ensure that the power cable for SP B is plugged into SPS B
and the power cable retention bails are in place.
5. Verify that the following sense cable serial connections are in place:
44
◆
SP A to SPS A
◆
SP B to SPS B
System Operations
Power up the VNX
6. Verify that the power cables for the SPSs are plugged into the appropriate cabinet power
strips on either side of the rack in a manner ensuring high availability and the power cable
retention bails are in place.
7. Verify that the power cables for any additional DAEs are plugged into the appropriate
cabinet power strips on either side of the rack in a manner ensuring high availability and
the power cable retention bails are in place.
8. Turn the SPS power switches ON.
9. Ensure that any other devices in the cabinet are correctly installed and ready for power
up.
10. Turn on the master switch/circuit breakers for each cabinet power strip.
In a 40U EMC cabinet, the master switches are on the power distribution panels (PDPs).
The storage system can take 10-12 minutes to complete a typical power up. Amber
warning LEDs flash during the power on self-test (POST) and then go off. The front fault
LED and the SPS recharge LEDs commonly stay on for several minutes while the SPSs
are charging.
11. You have completed the powerup of the system when the SP power LED on each SP is
steady green.
If amber LEDs on the front or back of the storage system remain on for more than 10
minutes, ensure that the system is correctly cabled, and then refer to the Troubleshooting
Trees on the EMC Support page for the storage system. If you cannot determine any
reasons for the fault, contact your authorized service provider.
VNX5300 powerup
45
Power up the VNX
VNX5500 powerup
The VNX5500 is available in three configurations: Block, File, and Unified. Follow the
instructions for your system configuration.
◆
VNX5500 for File/Unified powerup on page 46
◆
VNX5500 Block powerup on page 49
VNX5500 for File/Unified powerup
The VNX5500 for File and VNX5500 Unified can be configured with either one, two, or three
Data Movers and one or two Control Stations.
1. Verify that the master switch/circuit breakers for each cabinet power strip are ON.
2. Verify that the power switches on SPS A and SPS B are in the OFF position.
3. Ensure that the power cables for the Data Mover enclosures (two cables per enclosure)
and Control Stations (one cable per CS) are not connected to the PDUs.You will connect
these power cables later.
4. Ensure that the power cable for SP A is plugged into SPS A and the power cable retention
bails are in place.
5. Ensure that the power cable for SP B is plugged into SPS B and the power cable retention
bails are in place.
6. Verify that the following sense cable serial connections are in place:
◆
SP A to SPS A
◆
SP B to SPS B
7. Verify that the power cables for the SPSs are plugged into the appropriate cabinet power
strips on either side of the rack in a manner ensuring high availability and the power cable
retention bails are in place.
46
System Operations
Power up the VNX
8. Verify that the power cables for any additional DAEs are plugged into the appropriate
cabinet power strips on either side of the rack in a manner ensuring high availability and
the power cable retention bails are in place.
9. Turn the SPS power switches ON.
10. Connect all Data Mover enclosure power cables to the PDUs in a manner ensuring high
availability and wait for the Data Movers to power up. The blue power LED on the front
of the Data Mover enclosure will light when the Data Movers have powered up.
11. Wait 4-5 minutes as the Data Movers power up to ensure that the Data Movers have
booted and that they are ready. Then, connect the power cable for the Control Station 0
to the PDU.
Important: Do not plug in the power cable for CS 1, if present, at this time. CS 1 will be booted later
in this process.
12. Check the CS power LED (3 in the following figure) on the front of the Control Station
verify that the CS is booting. This green LED will blink as the CS boots and be on when
complete.
Note: The front bezel must be removed to for a clear view of the CS LEDs and to access the power
button of the Control Station.
VNX5500 powerup
47
Power up the VNX
If, after 5 minutes, this LED indicates that the Control Station is off, turn on the Control
Station by pressing the power button (1) on the front.
Ensure that the Control Station is powered up before continuing.
13. Check the system and hardware status as follows:
a. From a browser, type the IP address of the primary Control Station.
b. Log in to the Unisphere software as sysadmin and define the scope as Global.
c. Use the drop-down list at the topleft Dashboard to select the system name and view
its System Information.
d. On this page, verify that the Status fields for the VNX display OK.
e. Next, locate the Run Command option in Unisphere under Control Station CLI on the
righthand side of the System page and verify that CS 0 and the Data Movers booted
successfully by running a Control Station CLI command:
/nasmcd/sbin/getreason
Expected Reason Code values for booted VNX for File components:
10 - slot_0 primary control station
5 - slot_2 contacted
5 - slot_3 contacted
14. For dual Control Station systems only, once you have confirmed that CS 0 is up and
healthy, power up CS 1 by connecting the power cable for the CS 1 to a PDU on a different
circuit from CS 0 to ensure high availability.
48
System Operations
Power up the VNX
15. You have completed the powerup of the system when the SP power LED on each SP is
steady green.
If amber LEDs on the front or back of the storage system remain on for more than 10
minutes, ensure that the system is correctly cabled, and then refer to the Troubleshooting
Trees on the EMC Support page for the storage system. If you cannot determine any
reasons for the fault, contact your authorized service provider.
16. After completing the power up of the system, return to the Run Command option in
Unisphere and perform a system checkup:
nas_checkup
Fix issues discovered by the nas_checkup command in the manner indicated in its output.
VNX5500 Block powerup
Follow the instructions below for your VNX5500 for Block:
1. Verify that the master switch/circuit breakers for each cabinet power strip are OFF.
VNX5500 powerup
49
Power up the VNX
2. Verify that the power switches on SPS A and SPS B are in the OFF position.
3. Ensure that the power cable for SP A is plugged into SPS A and the power cable retention
bails are in place.
4. Ensure that the power cable for SP B is plugged into SPS B and the power cable retention
bails are in place.
5. Verify that the following sense cable serial connections are in place:
◆
SP A to SPS A
◆
SP B to SPS B
6. Verify that the power cables for the SPSs are plugged into the appropriate cabinet power
strips on either side of the rack in a manner ensuring high availability and the power cable
retention bails are in place.
7. Verify that the power cables for any additional DAEs are plugged into the appropriate
cabinet power strips on either side of the rack in a manner ensuring high availability and
the power cable retention bails are in place.
8. Turn the SPS power switches ON.
9. Ensure that any other devices in the cabinet are correctly installed and ready for power
up.
10. Turn on the master switch/circuit breakers for each cabinet power strip.
In a 40U EMC cabinet, the master switches are on the power distribution panels (PDPs).
The storage system can take 10-12 minutes to complete a typical power up. Amber
warning LEDs flash during the power on self-test (POST) and then go off. The front fault
LED and the SPS recharge LEDs commonly stay on for several minutes while the SPSs
are charging.
50
System Operations
Power up the VNX
11. You have completed the powerup of the system when the SP power LED on each SP is
steady green.
If amber LEDs on the front or back of the storage system remain on for more than 10
minutes, ensure that the system is correctly cabled, and then refer to the Troubleshooting
Trees on the EMC Support page for the storage system. If you cannot determine any
reasons for the fault, contact your authorized service provider.
VNX5700 powerup
The VNX5700 is available in three configurations: Block, File, and Unified. Follow the
instructions for your system configuration.
◆
VNX5700 for File/Unified powerup on page 51
◆
VNX5700 Block powerup on page 54
VNX5700 for File/Unified powerup
The VNX5700 for File and VNX5700 Unified can be configured with either two to four Data
Movers and one or two Control Stations.
1. Verify that the master switch/circuit breakers for each cabinet power strip are ON.
VNX5700 powerup
51
Power up the VNX
2. Verify that the power switches on SPS A and SPS B are in the OFF position.
3. Ensure that the power cables for the Data Mover enclosures (two cables per enclosure)
and Control Stations (one cable per CS) are not connected to the PDUs.You will connect
these power cables later.
4. Ensure that the power cable for SP A is plugged into SPS A and the power cable retention
bails are in place.
5. Ensure that the power cable for SP B is plugged into SPS B and the power cable retention
bails are in place.
6. Verify that the following sense cable serial connections are in place:
◆
SP A to SPS A
◆
SP B to SPS B
7. Verify that the power cable for LCC A on the vault DAE (EA 0, bus 0) is plugged into the
SPS A and the power cable retention bails are in place.
8. Verify that the power cable for LCC B on the vault DAE (EA 0, bus 0) is plugged into the
SPS B and the power cable retention bails are in place.
9. Verify that the power cables for the SPSs are plugged into the appropriate cabinet power
strips on either side of the rack in a manner ensuring high availability and the power cable
retention bails are in place.
10. Verify that the power cables for any additional DAEs are plugged into the appropriate
cabinet power strips on either side of the rack in a manner ensuring high availability and
the power cable retention bails are in place.
11. Turn the SPS power switches ON.
12. Connect all Data Mover enclosure power cables to the PDUs in a manner ensuring high
availability and wait for the Data Movers to power up. The blue power LED on the front
of the Data Mover enclosure will light when the Data Movers have powered up.
52
System Operations
Power up the VNX
13. Wait 4-5 minutes as the Data Movers power up to ensure that the Data Movers have
booted and that they are ready. Then, connect the power cable for the Control Station 0
to the PDU.
Important: Do not plug in the power cable for CS 1, if present, at this time. CS 1 will be booted later
in this process.
14. Check the CS power LED (3 in the following figure) on the front of the Control Station
verify that the CS is booting. This green LED will blink as the CS boots and be on when
complete.
Note: The front bezel must be removed to for a clear view of the CS LEDs and to access the power
button of the Control Station.
If, after 5 minutes, this LED indicates that the Control Station is off, turn on the Control
Station by pressing the power button (1) on the front.
Ensure that the Control Station is powered up before continuing.
15. Check the system and hardware status as follows:
a. From a browser, type the IP address of the primary Control Station.
b. Log in to the Unisphere software as sysadmin and define the scope as Global.
VNX5700 powerup
53
Power up the VNX
c. Use the drop-down list at the topleft Dashboard to select the system name and view
its System Information.
d. On this page, verify that the Status fields for the VNX display OK.
e. Next, locate the Run Command option in Unisphere under Control Station CLI on the
righthand side of the System page and verify that CS 0 and the Data Movers booted
successfully by running a Control Station CLI command:
/nasmcd/sbin/getreason
Expected Reason Code values for booted VNX for File components:
10 - slot_0 primary control station
5 - slot_2 contacted
5 - slot_3 contacted
16. For dual Control Station systems only, once you have confirmed that CS 0 is up and
healthy, power up CS 1 by connecting the power cable for the CS 1 to a PDU on a different
circuit from CS 0 to ensure high availability.
17. You have completed the power up of the system when the SP power LED on each SP
is steady green.
If amber LEDs on the front or back of the storage system remain on for more than 10
minutes, ensure that the system is correctly cabled, and then refer to the Troubleshooting
Trees on the EMC Support page for the storage system. If you cannot determine any
reasons for the fault, contact your authorized service provider.
18. After completing the power up of the system, return to the Run Command option in
Unisphere and perform a system checkup:
nas_checkup
Fix issues discovered by the nas_checkup command in the manner indicated in its output.
VNX5700 Block powerup
Follow the instructions below for your VNX5700 for Block:
54
System Operations
Power up the VNX
1. Verify that the master switch/circuit breakers for each cabinet power strip are OFF.
2. Verify that the power switches on SPS A and SPS B are in the OFF position.
3. Ensure that the power cable for SP A is plugged into SPS A and the power cable retention
bails are in place.
4. Ensure that the power cable for SP B is plugged into SPS B and the power cable retention
bails are in place.
5. Verify that the following sense cable serial connections are in place:
◆
SP A to SPS A
◆
SP B to SPS B
6. Verify that the power cable for LCC A on the vault DAE (EA 0, bus 0) is plugged into the
SPS A and the power cable retention bails are in place.
7. Verify that the power cable for LCC B on the vault DAE (EA 0, bus 0) is plugged into the
SPS B and the power cable retention bails are in place.
8. Verify that the power cables for the SPSs are plugged into the appropriate cabinet power
strips on either side of the rack in a manner ensuring high availability and the power cable
retention bails are in place.
9. Verify that the power cables for any additional DAEs are plugged into the appropriate
cabinet power strips on either side of the rack in a manner ensuring high availability and
the power cable retention bails are in place.
10. Turn the SPS power switches ON.
11. Ensure that any other devices in the cabinet are correctly installed and ready for power
up.
12. Turn on the master switch/circuit breakers for each cabinet power strip.
In a 40U EMC cabinet, the master switches are on the power distribution panels (PDPs).
VNX5700 powerup
55
Power up the VNX
The storage system can take 10-12 minutes to complete a typical power up. Amber
warning LEDs flash during the power on self-test (POST) and then go off. The front fault
LED and the SPS recharge LEDs commonly stay on for several minutes while the SPSs
are charging.
13. You have completed the power up of the system when the SP power LED on each SP
is steady green.
If amber LEDs on the front or back of the storage system remain on for more than 10
minutes, ensure that the system is correctly cabled, and then refer to the Troubleshooting
Trees on the EMC Support page for the storage system. If you cannot determine any
reasons for the fault, contact your authorized service provider.
VNX7500 powerup
The VNX7500 is available in three configurations: Block, File, and Unified. Follow the
instructions for your system configuration.
◆
VNX7500 for File/Unified powerup on page 56
◆
VNX7500 Block powerup on page 59
VNX7500 for File/Unified powerup
The VNX7500 for File and VNX7500 Unified can be configured with either two to eight Data
Movers and one or two Control Stations.
1. Verify that the master switch/circuit breakers for each cabinet power strip are ON.
56
System Operations
Power up the VNX
2. Verify that the power switches on SPS A and SPS B are in the OFF position.
3. Ensure that the power cables for the Data Mover enclosures (two cables per enclosure)
and Control Stations (one cable per CS) are not connected to the PDUs.You will connect
these power cables later.
4. Ensure that the power cable for SP A is plugged into SPS A and the power cable retention
bails are in place.
5. Ensure that the power cable for SP B is plugged into SPS B and the power cable retention
bails are in place.
6. Verify that the following sense cable serial connections are in place:
◆
SP A to SPS A
◆
SP B to SPS B
7. Verify that the power cable for LCC A on the vault DAE (EA 0, bus 0) is plugged into the
SPS A and the power cable retention bails are in place.
8. Verify that the power cable for LCC B on the vault DAE (EA 0, bus 0) is plugged into the
SPS B and the power cable retention bails are in place.
9. Verify that the power cables for the SPSs are plugged into the appropriate cabinet power
strips on either side of the rack in a manner ensuring high availability and the power cable
retention bails are in place.
10. Verify that the power cables for any additional DAEs are plugged into the appropriate
cabinet power strips on either side of the rack in a manner ensuring high availability and
the power cable retention bails are in place.
11. Turn the SPS power switches ON.
12. Connect all Data Mover enclosure power cables to the PDUs in a manner ensuring high
availability and wait for the Data Movers to power up. The blue power LED on the front
of the Data Mover enclosure will light when the Data Movers have powered up.
VNX7500 powerup
57
Power up the VNX
13. Wait 4-5 minutes as the Data Movers power up to ensure that the Data Movers have
booted and that they are ready. Then, connect the power cable for the Control Station 0
to the PDU.
Important: Do not plug in the power cable for CS 1, if present, at this time. CS 1 will be booted later
in this process.
14. Check the CS power LED (3 in the following figure) on the front of the Control Station
verify that the CS is booting. This green LED will blink as the CS boots and be on when
complete.
Note: The front bezel must be removed to for a clear view of the CS LEDs and to access the power
button of the Control Station.
If, after 5 minutes, this LED indicates that the Control Station is off, turn on the Control
Station by pressing the power button (1) on the front.
Ensure that the Control Station is powered up before continuing.
15. Check the system and hardware status as follows:
a. From a browser, type the IP address of the primary Control Station.
b. Log in to the Unisphere software as sysadmin and define the scope as Global.
58
System Operations
Power up the VNX
c. Use the drop-down list at the topleft Dashboard to select the system name and view
its System Information.
d. On this page, verify that the Status fields for the VNX display OK.
e. Next, locate the Run Command option in Unisphere under Control Station CLI on the
righthand side of the System page and verify that CS 0 and the Data Movers booted
successfully by running a Control Station CLI command:
/nasmcd/sbin/getreason
Expected Reason Code values for booted VNX for File components:
10 - slot_0 primary control station
5 - slot_2 contacted
5 - slot_3 contacted
16. For dual Control Station systems only, once you have confirmed that CS 0 is up and
healthy, power up CS 1 by connecting the power cable for the CS 1 to a PDU on a different
circuit from CS 0 to ensure high availability.
17. You have completed the power up of the system when the SP power LED on each SP
is steady green.
If amber LEDs on the front or back of the storage system remain on for more than 10
minutes, ensure that the system is correctly cabled, and then refer to the Troubleshooting
Trees on the EMC Support page for the storage system. If you cannot determine any
reasons for the fault, contact your authorized service provider.
18. After completing the power up of the system, return to the Run Command option in
Unisphere and perform a system checkup:
nas_checkup
Fix issues discovered by the nas_checkup command in the manner indicated in its output.
VNX7500 Block powerup
Follow the instructions below for your VNX7500 for Block:
VNX7500 powerup
59
Power up the VNX
1. Verify that the master switch/circuit breakers for each cabinet power strip are OFF.
2. Verify that the power switches on SPS A and SPS B are in the OFF position.
3. Ensure that the power cable for SP A is plugged into SPS A and the power cable retention
bails are in place.
4. Ensure that the power cable for SP B is plugged into SPS B and the power cable retention
bails are in place.
5. Verify that the following sense cable serial connections are in place:
◆
SP A to SPS A
◆
SP B to SPS B
6. Verify that the power cable for LCC A on the vault DAE (EA 0, bus 0) is plugged into the
SPS A and the power cable retention bails are in place.
7. Verify that the power cable for LCC B on the vault DAE (EA 0, bus 0) is plugged into the
SPS B and the power cable retention bails are in place.
8. Verify that the power cables for the SPSs are plugged into the appropriate cabinet power
strips on either side of the rack in a manner ensuring high availability and the power cable
retention bails are in place.
9. Verify that the power cables for any additional DAEs are plugged into the appropriate
cabinet power strips on either side of the rack in a manner ensuring high availability and
the power cable retention bails are in place.
10. Turn the SPS power switches ON.
11. Ensure that any other devices in the cabinet are correctly installed and ready for power
up.
12. Turn on the master switch/circuit breakers for each cabinet power strip.
In a 40U EMC cabinet, the master switches are on the power distribution panels (PDPs).
60
System Operations
Power up the VNX
The storage system can take 10-12 minutes to complete a typical power up. Amber
warning LEDs flash during the power on self-test (POST) and then go off. The front fault
LED and the SPS recharge LEDs commonly stay on for several minutes while the SPSs
are charging.
13. You have completed the power up of the system when the SP power LED on each SP
is steady green.
If amber LEDs on the front or back of the storage system remain on for more than 10
minutes, ensure that the system is correctly cabled, and then refer to the Troubleshooting
Trees on the EMC Support page for the storage system. If you cannot determine any
reasons for the fault, contact your authorized service provider.
VNX7500 powerup
61
Power up the VNX
62
System Operations
4
Shut down the VNX in an
emergency
This section explains how to shut down the VNX in case of an emergency.
Chapter 2 provides more specifics on normal (planned) powerdown
procedures.
Perform the following tasks to shut down the VNX in an emergency:
CAUTION These procedures can cause data loss or disrupt service to other
clients. Use these procedures only when faced with personal hazard or
possible property damage.
◆
◆
VNX series emergency shutdown on page 64
Power up after an emergency shutdown on page 64
System Operations
63
Shut down the VNX in an emergency
VNX series emergency shutdown
To shut down VNX systems in an emergency, turn off the two cabinet circuit-breaker switches.
CAUTION Turning off the cabinet circuit-breakers immediately removes power from Data Movers,
Control Station, storage array system, standby power supplies (SPSs), and any other equipment
connected to the cabinet’s PDU. No other action is required.
Power up after an emergency shutdown
After you use the emergency shutdown procedure, you might encounter errors or problems
when you try to restart the VNX server. If this occurs, record any error messages and contact
the EMC Customer Service immediately.
To power up a server after an emergency shutdown, follow Chapter 3.
64
System Operations
5
Halt and/or restart Control
Stations and Data Movers
Follow the tasks below to perform routine Control Station and Data Mover
power management tasks.
◆
◆
◆
Halt the Control Station on page 66
Restart the Control Station on page 67
Halt and/or restart Data Movers on page 69
System Operations
65
Halt and/or restart Control Stations and Data Movers
Halt the Control Station
This section explains how to perform an orderly halt of Control Stations in Unified, Integrated,
and Gateway servers. You can halt a Control Station either locally or remotely.
Perform these tasks to halt Control Stations either locally or remotely:
◆
Halt one Control Station, locally or remotely on page 66
◆
Halt dual Control Station, locally or remotely on page 66
Halt one Control Station, locally or remotely
This procedure applies to all VNX Unified and VNX File systems with a single Control Station.
1. Log in to the server as root.
Note: If logging in remotely, use a secure, encrypted, remote login application to log in to the server
as root.
2. Halt the Control Station by typing:
# /sbin/halt
The Control Station halts.
Halt dual Control Station, locally or remotely
This procedure applies to all VNX Unified and VNX File systems with two Control Stations.
Important: Always halt the secondary Control Station before the primary.
1. Log in to the server as root.
Note: If logging in remotely, use a secure, encrypted, remote login application to log in to the server
as root.
2. Determine which Control Station (CS 0 or CS 1) is primary and which is secondary by
typing:
66
System Operations
Halt and/or restart Control Stations and Data Movers
# /nasmcd/getreason
The primary Control Station returns a reason code of 10; the secondary Control Station
returns a reason code of 11.
3. If logged in to the primary CS, log in to the secondary Control Station as root.
Note: If logging in remotely, use a secure, encrypted, remote login application to log in to the
secondary CS as root.
4. Halt the secondary CS by typing:
# /sbin/halt
The secondary CS halts.
5. Log in to the primary Control Station as root.
Note: If logging in remotely, use a secure, encrypted, remote login application to log in to the primary
CS as root.
6. Halt the primary CS by typing:
# /sbin/halt
The primary CS halts.
Restart the Control Station
This section explains how to perform an orderly restart of Control Station(s) in a VNX Unified
and VNX File systems. Control Stations restart either locally or remotely.
Perform these tasks to restart Control Stations either locally or remotely:
◆
Restart one Control Station, locally or remotely on page 67
◆
Restart two Control Station, locally or remotely on page 68
Restart one Control Station, locally or remotely
This restart procedure applies to all VNX Unified and VNX File systems with a single Control
Station.
Restart the Control Station
67
Halt and/or restart Control Stations and Data Movers
1. Log in to the server as root.
Note: If logging in remotely, use a secure, encrypted, remote login application to log in to the server
as root.
2. Restart the CS by typing:
# reboot
The CS reboots.
Note: To continue working remotely, establish another remote connection.
Restart two Control Station, locally or remotely
This restart procedure applies to all VNX Unified and VNX File systems with a two Control
Stations.
1. Log in to the server as root.
Note: If logging in remotely, use a secure, encrypted, remote login application to log in to the server
as root.
2. Determine which Control Station (CS 0 or CS 1) is primary and which is secondary by
typing:
# /nasmcd/getreason
The primary Control Station returns a reason code of 10; the secondary Control Station
returns a reason code of 11.
3. If not already, log in to the primary Control Station as root.
Note: If logging in remotely, use a secure, encrypted, remote login application to log in to the primary
CS as root.
4. Restart the primary CS by typing:
# reboot
68
System Operations
Halt and/or restart Control Stations and Data Movers
The primary Control Station restarts and fails over to the secondary Control Station
(making it the new primary Control Station).
Do not go to the next step until the Control Station has finished restarting.
5. Log in to the new primary Control Station as root.
Note: If logging in remotely, use a secure, encrypted, remote login application to log in to the new
primary CS as root.
6. Restart the new primary CS by typing:
# reboot
The new primary Control Station restarts and fails over to the original primary Control
Station (returning it the primary Control Station).
Note: To continue working remotely, establish another remote connection.
Halt and/or restart Data Movers
This section explains how to perform an orderly halt or reboot of Data Movers in Unified,
Integrated, and Gateway servers. You can halt or reboot a Data Mover either locally or
remotely.
◆
Halt the Data Movers on page 69
◆
Restart a Data Mover on page 70
Halt the Data Movers
The following procedure explains how to perform an orderly, timed, or immediate halt of a
network server’s Data Mover. This procedure applies to all VNX Unified and VNX File
systems.
Note: A Data Mover is also called a blade. There is no functional difference between a Data Mover
and a blade.
To immediately halt a Data Mover, use this command syntax:
$ server_cpu <movername> -halt <time>
where:
Halt and/or restart Data Movers
69
Halt and/or restart Control Stations and Data Movers
◆
<movername> = name of the Data Mover
◆
<time> = when the Data Mover is to be halted, specified as one of the following:
{ now | +<min> | <hour>:<min> }
Example:
To halt server_5 immediately, type:
$ server_cpu server_5 -halt now
server_5 : done
Restart a Data Mover
The following procedure explains how to perform an orderly, timed or immediate restart of
the network server’s Data Movers. The procedure applies to all VNX Unified and VNX File
systems.
To immediately restart and monitor a Data Mover, use this command syntax:
$ server_cpu <movername> -reboot [cold|warm] -monitor <time>
where:
◆
<movername> = name of the Data Mover
◆
[cold|warm]= defines the degree to which the Data Mover is reset.
◆
•
A cold reboot or a hardware reset shuts down the Data Mover completely before
restarting, including a Power on Self Test (POST).
•
A warm reboot or a software reset performs a partial shutdown of the Data Mover,
and skips the POST after restarting. A software reset is faster than the hardware
reset.
<time> = when the Data Mover is to be restarted, specified as one of the following:
{ now | +<min> | <hour>:<min> }
Note: The default parameter of the -reboot option will be the warm parameter. In case the warm
rebooting fails, the -reboot option will use the cold parameter to reboot the Data Mover.
Example 1:
To monitor an immediate cold restart of server_5, type:
$ server_cpu server_5 -reboot cold -monitor now
Example 2:
To monitor an immediate warm restart of server_5, type:
70
System Operations
Halt and/or restart Control Stations and Data Movers
$ server_cpu server_5 -reboot -monitor now
server_5 : reboot in progress .....3.4.4.done
Note: You can verify when the system is back online by using /nas/sbin/getreason.
Code 5 indicates the Data Mover is available.
You might also see the following codes as the Data Mover restarts:
◆ 0 - (reset) - Data Mover performing BIOS check, then begins boot sequence
◆ 1 - (POST pass) - Data Mover passes POST
◆ 3 - (loaded) - Operating system loaded and initializing
◆ 4 - (ready) - Operating system initialized
◆ 5 - (contacted) - Data Mover available
Halt and/or restart Data Movers
71
Halt and/or restart Control Stations and Data Movers
72
System Operations
6
View and manage system
details
Find details about viewing and managing general system settings.
◆
◆
◆
◆
◆
◆
◆
◆
Identify the software versions on page 74
Audit the VNX on page 74
Check the system status on page 76
Change the Control Station hostname on page 77
Install Control Station Linux security alerts on page 79
Verify the daemons on page 80
Back up the VNX database on page 81
Query VNX for SCSI details on page 84
System Operations
73
View and manage system details
Identify the software versions
To determine the software versions on the Control Station or Data Mover, use the following:
◆
View Control Station software version on page 74
◆
View Data Mover software version on page 74
View Control Station software version
To view the software version running on the Control Station, type:
$ nas_version -l
Name
: emcnas
Version
: 7.1.21
Release
: 1
06:54:59 PM EST
Size
: 753358063
Signature
: (none)
Packager
: EMC Corporation
URL
: http://www.emc.com
Summary
: EMC nfs base install
Description :
EMC nfs base install
Relocations: /nas
Vendor: EMC
Build Date: Wed 10 Dec 2012
License: EMC Copyright
View Data Mover software version
To view the software version running on a Data Mover, type:
$ server_version <movername>
where <movername> = name of the Data Mover
For example:
$ server_version server_3
server_3 : Product: EMC File Server
Version: T7.1.21
Audit the VNX
The Control Station provides powerful system auditing capabilities. VNX auditing provides
a method to audit/detect access to the Data Mover file systems from the Control Station.
Auditing is enabled by default on the Control Station after a fresh install and a Control Station
recovery.
Verify if auditing is enabled, by:
74
System Operations
View and manage system details
1. Log in to the server as root.
2. To check if auditing in running on the Control Station, type:
# /sbin/service auditd status
Output:
auditd (/spid 13367) is running...
Note: For more information about configuring VNX auditing, refer to Auditing the VNX Control
Station Technical Note.
Audit the VNX
75
View and manage system details
Check the system status
Use the nas_checkup command to perform a health checkup for the VNX.
nas_checkup runs scheduled and unscheduled health checks on the VNX and reports
problems that are found, and the actions needed to fix the problem and acts as a system
health monitor.
The scheduled run time for the nas_checkup command is every 2 weeks by default. If a
warning or error is discovered during this time, an alert is posted on the Unisphere software.
Set up email notification for warnings or errors in the Unisphere software Notifications page,
or modify and load the sample nas_checkup event configuration file.
nas_checkup returns one of the following exit statuses for system diagnostics:
◆
0 — No problems found
◆
1 — nas_checkup posted information
◆
2 — nas_checkup discovered a warning
◆
3 — nas_checkup discovered an error
◆
255 — Any other error
Examples of errors that could cause a 255 exit status include, but are not limited to:
◆
If nas_checkup is run when another instance of nas_checkup is running
◆
If nas_checkup is run by someone other than root or the administrator group (generally
nasadmin)
◆
If nas_checkup is run on the standby Control Station
If a problem is discovered that requires EMC Service Personnel assistance, nas_checkup
will notify EMC.
To perform a checkup of the VNX File, use this command syntax:
$ nas_checkup
76
System Operations
View and manage system details
Change the Control Station hostname
You can change a VNX server’s Control Station hostname. The following procedure uses
the CLI. However, if you use the Unisphere software to manage the server, use it to make
the hostname change instead.
In the following procedure, the Control Station hostname was changed from Eng_1 to cs100.
CAUTION If you use the CLI to change the Control Station hostname and use the Unisphere
software to manage the server, ensure that you follow this procedure carefully. Otherwise, you
will not be able to create file systems by using the Unisphere software.
Add the new hostname to either DNS or the VNX system. To make changes to DNS, check
the DNS documentation. This procedure adds the new hostname to the VNX system only.
1. Log in to the Control Station as root.
2. To verify the current environment, type:
# hostname
Output:
Eng_1
3. To display information about the Control Station, including its hostname and ID, type:
# /nas/bin/nas_cel -list
Output:
id
name
owner
0
Eng_1
0
APM04490091900
mount_dev
channel
net_path
CMU
172.24.101.100
4. To change the hostname of the Control Station, type:
# /nas/bin/nas_cs -set -hostname <new_hostname>
Output:
OK
5. To confirm the hostname of the Control Station, type:
# /nas/bin/nas_cel -list
Output:
Change the Control Station hostname
77
View and manage system details
id
name
owner
0
cs100
0
APM04490091900
mount_dev
channel
net_path
CMU
172.24.101.100
6. To change the SSL certificate for Apache, type:
# /nas/sbin/nas_config -ssl
Output:
Installing a new SSL certificate requires restarting the Apache
web server.
Do you want to proceed? [y/n]: y
New SSL certificate has been generated and installed successfully.
78
System Operations
View and manage system details
Install Control Station Linux security alerts
EMC monitors Linux security alerts and carefully evaluates how the associated errata apply
to Control Station Linux. Be sure to install only EMC-approved security updates on the VNX.
You can have them installed anytime either during the installation of a new VNX software
release or between the installation of new software releases.
New software release installations
EMC-approved Linux security updates are automatically installed on the VNX each time
a new VNX software release is installed.
Between software release installations
If you want to install a current Linux security update before installing a new VNX software
release, contact the EMC Customer Service. Only EMC-approved security updates
should be installed on the VNX.
Install Control Station Linux security alerts
79
View and manage system details
Verify the daemons
After installation, daemons begin running on the Control Station at all times. If for some
reason the daemons become disabled, certain server facilities might fail.
Perform these tasks to verify whether VNX daemons are enabled:
◆
New software release installations on page 136
◆
View HTTPD daemons on page 80
View VNX daemons
To view the VNX daemons enabled at the Control Station, type:
$ ps -e|grep nas | awk ' { print $4 } ' | sort | uniq
The following appears:
nas_boxmonitor
nas_eventcollec
nas_eventlog
nas_mcd
nas_watchdog
Note:
The complete list of daemons is displayed in the output above, but the output list for your server
might be different.
If the daemons are not running, restart them by typing:
/etc/rc.d/init.d/nas stop
/etc/rc.d/init.d/nas start
View HTTPD daemons
It is essential that the HTTPD daemons run on the Control Station at all times, so the
Unisphere software can manage the VNX.
To view whether the HTTPD daemons are enabled at the Control Station and to reenable
them if necessary, type:
$ ps -e|grep httpd
The following appears:
80
System Operations
View and manage system details
15937
15949
15950
15951
15964
15965
15966
15995
16008
?
?
?
?
?
?
?
?
?
00:00:10
00:00:00
00:00:00
00:00:00
00:00:00
00:00:00
00:00:00
00:00:00
00:00:00
httpd
httpd
httpd
httpd
httpd
httpd
httpd
httpd
httpd
Note:
If the HTTPD daemons are not running, restart the Unisphere software by switching to root and
typing:
# /nas/http/nas_ezadm/etc/script restart
Back up the VNX database
VNX database created by the VNX software during installation is stored on disk in the Control
Station. The VNX database maintains vital information required for each Data Mover. The
VNX File software automatically creates a VNX database backup file 1 minute after each
hour. You can manually create a VNX database backup file at any time.
Perform these tasks to back up the VNX database:
◆
New software release installations on page 136
◆
Manual VNX database backup on page 82
CAUTION
◆ EMC strongly recommends that you regularly copy the VNX database backup file
from the Control Station and save it to a remote location for safe keeping. Always
copy the VNX database backup file when hardware or software upgrades are
planned.
◆ Only EMC qualified support personnel should restore the VNX database by using
the VNX database backup file.
◆ Do not manually edit the nas_db database without consulting Customer Service.
Any changes you make might disrupt services.
Back up the VNX database
81
View and manage system details
Automatic VNX database backup
The VNX automatically backs up the entire database and saves it to a file named
nasdb_backup.1.tar.gz in the /nas/var/backup directory. It does this 1 minute after each
hour. It also maintains the last 12 backup files.
To copy a VNX database backup file to a remote location, use FTP as described in Using
FTP, TFTP and SFTP on VNX.
Manual VNX database backup
Use this procedure to back up and save a copy of the VNX database without waiting for an
hourly automatic backup.
1. Log in to the primary Control Station as nasadmin.
2. List the VNX database backup files by typing:
$ ls –l nasdb*
A display similar to the following appears:
-rw-r--r-- 1 nasadmin nasadmin 1920308 May 4 12:03
nasdb_backup.1.tar.gz
-rw-r--r-- 1 nasadmin root 1022219 Mar 23 19:32
nasdb_backup.b.tar.gz
Ensure that a version of nasdb_backup.1.tar is listed with the current date and time. If a
current version is not present, ensure that nasadmin is the group and owner of
nasdb_backup.1.tar.gz and _nasbkup.
3. To ensure that the VNX database backup does not fill the root file system, check the root
file system free space by typing:
$ df -k /
The system returns the amount of space in the root directory in kilobytes (KB). Ensure
that the free space is more than the size of the most recent VNX database backup.
4. Create a backup file of the VNX database by using this command syntax:
$ /nas/sbin/nasdb_backup /nas /celerra/backup <yymmdd>
where <yymmdd> is the last two digits of the current year, the two-digit month, and the
two-digit day.
The following appears:
NAS_DB backup in progress .....NAS_DB checkpoint in
progress.....done
82
System Operations
View and manage system details
5. Examine the date and time to verify that a new version of nasdb_backup.<yymmdd>.tar.gz
was created by typing:
$ ls -l celerra/backup*
A display similar to the following appears:
total 46208
-rw-r--r-- 1 nasadmin nasadmin 2700 Feb 5 13:01
_dbms_backup.01.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 2702 Feb 5 14:01
_dbms_backup.02.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 2702 Feb 5 14:01
_dbms_backup.OK.tar.gz
drwx------ 2 root root 16384 Feb 1 11:27 lost+found
-rw-r--r-- 1 nasadmin nasadmin 3163954 Feb 5 13:01
_nasbkup.01.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 3163960 Feb 5 14:01
_nasbkup.02.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 3163941 Feb 5 03:01
_nasbkup.03.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 3163965 Feb 5 04:01
_nasbkup.04.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 3163959 Feb 5 05:01
_nasbkup.05.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 3163934 Feb 5 06:01
_nasbkup.06.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 3163945 Feb 5 07:01
_nasbkup.07.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 3163957 Feb 5 08:01
_nasbkup.08.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 3163964 Feb 5 09:01
_nasbkup.09.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 3163922 Feb 5 10:01
_nasbkup.10.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 3163960 Feb 5 11:01
_nasbkup.11.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 3163954 Feb 5 12:01
_nasbkup.12.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 4407468 Feb 5 14:01
nasdb_backup.1.tar.gz
-rw-r--r-- 1 nasadmin nasadmin 4268888 Feb 1 11:33
nasdb_backup.b.tar.gz
drwxrwxr-x 2 root root 4096 Feb 1 12:01 SCCS
-rwx------ 1 root root 528384 Feb 1 12:01 wpart
6. Using secure FTP, copy the VNX database file nasdb_backup.<yymmdd>.tar.gz and
nasdb_backup.b.tar.gz to a remote location.
Note: The backup file should not be copied to the Data Mover because Data Movers might not be
functional if VNX database gets corrupted.
Back up the VNX database
83
View and manage system details
Query VNX for SCSI details
The Control Station database maintains a list of all SCSI devices. When required, you can
probe the storage system to discover and save the present SCSI devices for a specific Data
Mover.
Discover SCSI devices
To discover all SCSI devices for the specified Data Mover, use this command syntax:
$ server_devconfig <movername> -probe -scsi -all
where <movername> = name of the Data Mover
For example, the following command and output pair discovers all SCSI devices for DM
2, named server_2:
$ server_devconfig server_2 -probe -scsi -all
server_2 :
SCSI disk devices :
chain= 0, scsi-0
symm_id= 0 symm_type= 0
tid/lun= 0/0 type= disk
tid/lun= 0/1 type= disk
tid/lun= 1/0 type= disk
tid/lun= 1/1 type= disk
tid/lun= 1/2 type= disk
tid/lun= 1/3 type= disk
tid/lun= 1/4 type= disk
tid/lun= 1/5 type= disk
tid/lun= 1/6 type= disk
tid/lun= 1/7 type= disk
tid/lun= 1/8 type= disk
tid/lun= 1/9 type= disk
sz=
sz=
sz=
sz=
sz=
sz=
sz=
sz=
sz=
sz=
sz=
sz=
4153
4153
8631
8631
8631
8631
8631
8631
8631
8631
8631
8631
val=
val=
val=
val=
val=
val=
val=
val=
val=
val=
val=
val=
1 info= 526691000051
2 info= 526691001051
3 info= 52669100C051
4 info= 52669100D051
5 info= 52669100E051
6 info= 52669100F051
7 info= 526691010051
8 info= 526691011051
9 info= 526691012051
10 info= 526691013051
11 info= 526691014051
12 info= 526691015051
Note: If you attempt to view SCSI devices and the system stops responding, the storage system
might be offline. To solve this, verify that the storage system is online and then retry the procedure.
CAUTION Discovering or saving SCSI devices is time-consuming for the server, so it is better
to do it during nonpeak times when resources are available. Discovering and saving SCSI
devices might cause temporary service disruption to the VNX.
Save SCSI devices
You can save SCSI devices to the device table. Before using the -create option, ensure
that you back up the existing camdisk file located in the /nas/server/slot_# directory.
To discover and save all SCSI devices for a Data Mover, use this command syntax:
$ server_devconfig <movername> -create -scsi -all
84
System Operations
View and manage system details
where <movername> = name of the Data Mover
For example, the following command and output pair discovers and saves all SCSI
devices for DM 2, named server_2:
$ server_devconfig server_2 -create -scsi -all
server_2 : done
Query VNX for SCSI details
85
View and manage system details
86
System Operations
7
Manage VNX time and date
settings
Find details about setting timezone values, managing NTP service, and
setting the time and date for the VNX system in the sections that follow.
◆
◆
◆
Set the date and time of the VNX on page 88
Configure NTP service using the CLI on page 90
Set the time zone of the VNX on page 90
System Operations
87
Manage VNX time and date settings
Set the date and time of the VNX
To set the date and time of a Control Station or a Data Mover:
◆
Set Control Station date and time on page 88
◆
Set Data Mover date and time on page 88
Set Control Station date and time
Before you begin
You must log in as root on the primary Control Station to perform this operation.
Procedure
To set the date and time for a primary Control Station, use this command syntax:
# nas_cs -set -time <yyyymmddhhmm [ss]>
where <yyyymmddhhmm [ss]> = date and time (seconds, optional) format
Note: Additionally, you can define the timezone and NTP servers, using the -timezone and
-ntp_servers nas_cs switches, respectively. For more information review your system Command
Reference Manual.
Example:
To set the date and time to 2:40 P.M. on July 2, 2012, type:
# nas_cs -set -time 201207021440
OK
Note: To view the output, type date at the command prompt.
Set Data Mover date and time
You can customize the display of the date and time on a Data Mover by using the server_date
command. Configuring Time Services on VNX provides additional information on time
services.
To set the current date and time for a Data Mover, use this command syntax:
$ server_date <movername> <yymmddhhmm> [<ss>]
where:
88
System Operations
Manage VNX time and date settings
◆
<movername> = name of the Data Mover
◆
<yymmddhhmm> [<ss>] = where <yy> is the year; the first <mm> is the month; <dd> is the
day; <hh> is the hour (in 24-hour system); and the second <mm> is the minute, and <ss>
is the second.
Example:
To set the date and time on server_2 to July 4, 2005, 10:30 A.M., type:
$ server_date server_2 0507041030
server_2 : done
Set the date and time of the VNX
89
Manage VNX time and date settings
Configure NTP service using the CLI
Note: For more information about the configuring NTP, refer to the Configuring Time Services on VNX
technical module.
1. Log in to the primary Control Station as root.
2. View the current time, date, NTP settings on the primary Control Station:
# nas_cs -info
3. Add or remove NTP servers from the Control Station:
◆
To add an NTP server:
# nas_cs -set -ntp_servers <ntp_server_IP_address>
Note: When adding multiple NTP servers at one time, type the IP addresses for each NTP
server to be added in a comma-separated list.
◆
To clear all NTP servers:
# nas_cs -clear -ntp_servers
4. View the updated time, date, NTP settings on the primary Control Station:
# nas_cs -info
Set the time zone of the VNX
You can update the time zone information on the Data Mover by using simple and
decipherable strings that correspond to the time zones available in the Control Station. You
can also update the daylight savings time on the Data Mover for the specified time zone.
◆
Change Control Station time zone manually using the CLI on page 90
◆
Set Data Mover time zone manually on page 91
Change Control Station time zone manually using the CLI
1. Log in to the primary Control Station as root.
90
System Operations
Manage VNX time and date settings
2. To verify the current environment, type:
# date
Output:
Mon Feb 27 16:42:52 EST 2012
3. Change the timezone:
Note: To view a list of the supported timezones, at the command prompt, type:
# nas_cs -info -timezone
# nas_cs -set -timezone <supported_timezone>
Example:
# nas_cs -set -timezone America/Denver
Warning 17985699848: The time zone has been set successfully. Reboot the
Control Station.
4. Reboot the primary CS:
Note: If the system is configured with two Control Stations, you will need to power down the
secondary Control Station prior to rebooting the primary CS.
# nas_cs -reboot
5. To verify the current environment, type:
# date
Output:
Mon Feb 27 14:42:52 MTN 2012
6. If you powered down the secondary CS earlier, power on CS 1 at this time.
The time zone of the Control Station is changed to the new location specified
Set Data Mover time zone manually
1. Log in to the Control Station as root.
Set the time zone of the VNX
91
Manage VNX time and date settings
2. To set the time zone on a Data Mover using the Linux time zone method, use this
command syntax:
$ server_date <movername> timezone -name <timezonename>
where:
◆
<movername> = name of the Data Mover
◆
<timezonename> = a Linux style time zone specification
Example:
To set the time zone to Central Time and adjust the daylight savings time for a Data
Mover by using the Linux method, type:
$ server_date server_2 timezone -name America/Chicago
Output:
server_2 : done
92
System Operations
8
Manage networking
Manage the VNX networking settings and values using the following
sections:
◆
◆
◆
◆
◆
◆
Configure IPv6 on the Control Station on page 94
Configure SNMP on page 95
Avoid private LAN IP address conflicts on page 96
Add DNS Server on page 96
Configure IP aliasing on page 97
Change VNX management port IP address values on page 100
System Operations
93
Manage networking
Configure IPv6 on the Control Station
The Control Station supports IPv6 through a dual-stacking implementation of IPv4 and IPv6
network addresses. To implement and manage this feature, a new CLI command, nas_cs,
has been introduced to manage the configuration properties of the Control Station.
Note: For more information about nas_cs and configuring IPv6 on the Control Station, refer to VNX
Command Line Interface Reference for File.
To set the IPv6 address of a primary Control Station, it must be implemented alongside
IPv4. To implement dual-stacking of IPv4 and IPv6 addresses through the CLI follow the
process below.
# nas_cs -set -ip6address <ipv6_address[/prefix_length]> -ip6gateway
<ipv6_gateway>
where:
<ipv6_address[/prefix_length]>= the IPv6 network address of the primary Control Station.
TheIPv6 address must be a valid address. The /prefix_length option sets the integer value,
between 8 and 128, for the prefix length of the IPv6 address of the primary Control Station.
<ipv6_gateway>= the IPv6 network address of the gateway machine for the primary Control
Station on the network. The IPv6 address must be a valid address.
Example:
To set the IPv6 address and the IPv6 gateway for the primary Control Station, type:
# nas_cs -set -ip6address 2002:ac18:af02:f4:20e:cff:fe6e:d524/64 - ip6gateway
2002:ac18:af02:f4:20e:cff:fe6e:d527
OK
94
System Operations
Manage networking
Configure SNMP
The SNMP collects and processes valuable network information. It gathers data by polling
the devices on the network from a management station at fixed or random intervals. When
the network is operating ideally, SNMP establishes a state that is called a baseline, which
lists all of the operational parameters.
The SNMP protocol acts as a network safeguard against irregularities that might hamper
the functioning of the network. The SNMP agent, the SNMP daemon (SNMPD), which runs
on the Data Mover, supports SNMPv1, SNMPv2c, and SNMPv3. The SNMPD service is
started, but unconfigured, by default.
For more information about SNMP and SNMPv3, refer to Using SNMPv3 on VNX and the
server_snmpd man pages.
View SNMP status
To view the SNMP service status for all Data Movers, type:
$ server_snmpd ALL -service -status
Output:
server_2:
SNMP Running
server_3:
SNMP Stopped
Note: Only a single SNMPD runs on each Data Mover. In the event of a failover, the standby Data
Mover runs the SNMPD.
Configure SNMP
95
Manage networking
Avoid private LAN IP address conflicts
VNX servers use a private LAN for communication between the Control Stations and Data
Movers. This LAN is sometimes also called a local or internal LAN. By default, this private
LAN uses IP addresses in the following three subnets:
◆
128.221.252.nnn — This subnet is the primary private LAN. For the NS series servers,
this LAN connects to the LAN switch on the Control Station 0 tray assembly.
◆
128.221.253.nnn — This subnet is the secondary (or backup) private LAN. For the VNX
server with two Control Stations, the secondary LAN connects to the LAN switch on the
Control Station 1 tray assembly. For a single Control Station NS series server, it shares
the same network as the primary private LAN, which uses the LAN switch on the Control
Station 0 tray assembly.
◆
128.221.254.nnn — This subnet is used for the Intelligent Platform Management Interface
(IPMI) connection between two Control Stations. IPMI enables one Control Station to
restart the other. The subnet consists of a crossover cable connected between ports on
the two Control Stations. This subnet is not used for single Control Station servers.
Although the VNX private LAN does not connect to the public LAN, the Data Movers (or
blades) and Control Stations do connect to both the private and public. If you are using these
default subnet addresses in the public network, the VNX equipment installer gave the VNX
private LAN new addresses at installation time. Ensure that you have these new addresses.
Note: To prevent server disruption, do not connect the private LAN Ethernet switch to any other network,
network device, or host.
If you have more than one VNX server, each server can have the same set of private LAN
addresses. A conflict occurs only when the same subnet exists in both the public and private
LANs.
If you change the network configuration after the VNX server is installed, avoid using the
VNX private LAN subnets. If you must use them, reconfigure the VNX private LAN to use
different subnet addresses.
If you still have questions after reading this section, contact the EMC Customer Service for
assistance to avoid creating conflicting subnets.
Add DNS Server
Before you begin
Only a global user who has the privileges associated with the Administrator or Security
Administrator role can configure DNS settings.
96
System Operations
Manage networking
Note: The list of DNS Server IP addresses is an ordered list. Both IPv4 and IPv6 addresses are
acceptable. The VNX for block OE will always prefer IPv6 addresses (if the addresses have been
configured) over IPv4, even if the addresses are ordered differently at configuration time.
Procedure
To add a DNS Server:
1. Select All Systems > Domains, and from the Local Domain task list, click Configure DNS.
Alternatively, select the system, and then select Settings, and from the Network Settings
task list, click Configure DNS.
DNS Configuration for Storage Domain appears.
2. In DNS Domain Suffix, if the displayed domain suffix is not correct for the DNS Server
you are adding, type the valid domain suffix for the DNS Server.
If the domain suffix has never been set, the field is empty.
3. In DNS Server IP Address, type the IP address of the server (either an IPv4 or IPv6 address
is acceptable) in the box to the left of Add.
4. Click Add.
The IP address entry appears at the bottom of the list.
5. If required, you can click an IP address and use Move Up or Move Down to position the
IP address in the list.
6. If the domain suffix does not appear in Domain Search List, type the valid domain suffix
for the DNS Server in the box to the left of Add.
7. Click Add.
The domain suffix entry for the DNS Server appears at the bottom of the list.
8. If required, you can click a domain suffix and then use Move Up or Move Down to position
the domain suffix in the list.
9. Click OK to save any changes.
Configure IP aliasing
IP aliasing allows different IP addresses to point to the same network device. The VNX
allows you to configure IP aliasing for a Control Station. This enables communication with
Configure IP aliasing
97
Manage networking
the primary Control Station by using a single IP address regardless of whether the primary
Control Station is running in slot 0 or slot 1.
To create or delete an IP alias:
Note: Any IP address entered is checked to ensure that it is valid and not used by another network
device.
◆
Create an IP alias on page 98
◆
Delete an IP alias on page 99
Create an IP alias
1. Log in to the server as root.
2. To create an IP alias for the Control Station, use one of the following scripts:
◆
For an IPv4 IP alias, use:
# /nas/sbin/nas_config -IPalias -create 0
◆
For an IPv6 IP alias, use:
# /nas/sbin/nas_config -IPalias -create6 0
3. To use a new IP address as the IP alias, answer no to the question and then type the
new IP address to use as an IP alias within the same network.
For example, when the script prompts:
Do you want slot_0 IP address <1.2.3.4> as your alias [yes or no]: no
Please enter an IP address to use as an alias: 1.2.3.6
4. To use the current IP address as the IP alias, answer yes to the question, and then type
a new IP address to replace the current IP address.
For example, when the script prompts:
Do you want slot_0 IP address <1.2.3.4> as your alias [yes or no]: yes
Please enter an IP address to use as an alias: 1.2.3.6
5. To view the IP alias you created:
◆
98
For an IPv4 IP alias, use:
System Operations
Manage networking
# /nas/sbin/nas_config -IPalias -list
◆
For an IPv6 IP alias, use:
# /nas/sbin/nas_config -IPalias -list6
Delete an IP alias
1. To delete an IP alias using the script, type:
◆
For an IPv4 IP alias, use:
# /nas/sbin/nas_config -IPalias -delete 0
◆
For an IPv6 IP alias, use:
# /nas/sbin/nas_config -IPalias -delete6 0
2. Type yes to delete the IP alias at the prompt shown below:
All current sessions using alias eth2:0 will terminate
Do you want to continue [yes or no]: yes
done
3. To view the result, type:
◆
For an IPv4 IP alias, use:
# /nas/sbin/nas_config -IPalias -list 0
◆
For an IPv6 IP alias, use:
# /nas/sbin/nas_config -IPalias -list6 0
Configure IP aliasing
99
Manage networking
Change VNX management port IP address values
The network properties are initially set by EMC service personnel to work at your site. We
strongly recommend that you do not change any value unless you are moving the SP to
another LAN or subnet.
Change the IP addresses for VNX for File/Unified management ports
Note: Do not attempt to change the IP addresses of a VNX system using Unisphere, you will lose
management access to this storage system.
To properly change the IP addresses of this system, refer to the Changing VNX
File/Unified IP Addresses procedure located in the Related Documents on
https://mydocs.emc.com/VNX for instructions on changing management ports IP
addresses.
Change the IP addresses for VNX Gateway management ports
VNX series gateway servers that use a VNX for Block or CLARiiON storage array
communicate with the array over the public LAN. The IP addresses of the VNX for Block
or CLARiiON storage processor (SP) management ports are stored as part of the VNX
File configuration. If you need to change the IP addresses of the SP management ports,
you must reconfigure the server to use the new addresses.
Note: Do not attempt to change the IP addresses of a VNX system using Unisphere, you will lose
management access to this storage system.
To properly change the IP addresses of this system, refer to the Changing VNX Gateway
IP Addresses procedure located in the Related Documents on
https://mydocs.emc.com/VNX for instructions on changing management ports IP
addresses.
100
System Operations
9
Manage logging and
alerting capabilities
Configure VNX logging and alert capabilities using the following sections.
◆
◆
◆
◆
◆
◆
Change the ConnectHome settings on page 102
Set the country code on the MT5634ZBA modem on page 111
Interpret log files on page 116
VNX and RSA Envision on page 122
NAS or SAN environment rules on page 123
VNX for file problem information on page 125
System Operations
101
Manage logging and alerting capabilities
Change the ConnectHome settings
The VNX ConnectHome function automatically notifies the EMC service center or other
service provider if the VNX system detects a serious problem. ConnectHome sends messages
by using email, FTP server, or the VNX modem and a customer supplied analog telephone
line.
Configure Connect Home
EMC recommends that ESRS transport be configured as the primary transport.
If necessary, EMC recommends that Email transport be configured as the secondary transport
and that you keep the default EMC recipient address, emailalert@emc.com, unless otherwise
specified by your authorized service provider. Be sure to update the settings if your Site ID
or dial-in information changes.
Note: To pause and resume the Connect Home service, and to clear the pending Connect Home event
files, use the nas_connecthome -service command.The online man page for nas_connecthome
provides more information.
Configure the sender address of the email transport using the nas_connecthome command
with the site administrator's email address to capture the email relay errors.
To change any of the properties, you must be logged in as root.
1. Select System.
2. From the task list, under Service Tasks, select Manage Connect Home.
If you access the ConnectHome page and every transport mechanism is disabled, an
informational message appears on top of the ConnectHome page. The message instructs
you to configure a transport mechanism and recommends the ESRS transport mechanism.
If you access the ConnectHome page and the ESRS is disabled on the Control Station,
an informational message appears on top of the ConnectHome page. The message
notifies you that the ESRS is disabled and instructs you to enable it. In this case, the
ESRS Priority drop-down list is disabled until ESRS is provisioned.
3. In the Your Site ID field, type the name of your site, if known.
4. The Enable dial-in is selected by default.
This option allows support personnel to access your Control Station remotely; it is intended
for modem dial in.
102
System Operations
Manage logging and alerting capabilities
5. In the Number to Dial In (Modem) field, type the modem number of the VNX system. Be
sure to include country and city codes, if applicable.
If your VNX system has two modems, one for each Control Station, type both dial-in
phone numbers.
First, type the modem number for Control Station 0, followed by a slash (/), and then the
modem number for Control Station 1. You cannot enter more than 31 characters.
Examples:
Numbers without extension: 912344356000/912344356001
Numbers with extension: 911239549842x6095/x6096
6. Enable or disable encryption using the Enable Encryption.
Encryption is used for ESRS, email and FTP only, and is enabled by default. This option
allows encryption of all transport type payloads during transmission.
7. Use the ESRS Priority drop-down list to set or modify ESRS as a primary, secondary, or
tertiary transport mechanism.
If ESRS is disabled, Disabled appears in the ESRS Priority drop-down list and the list is
disabled. You must click Manage ESRS Settings to open the Manage ESRS page and
provision ESRS. See Provision ESRS on page 105 for instructions. When ESRS
provisioning is completed, the drop-down list is enabled. Also, if you need to re-provision
the ESRS, click Manage ESRS Settings to open the Manage ESRS page and make any
necessary changes to ESRS. See Re-provision ESRS on page 107 for instructions.
This selection refers to using the ESRS software on the Control Station which is included
as part of the VNX Operating Environment (OE). The ESRS software on the Control
Station should not be used in conjunction with the ESRS IP Client for VNX software which
must be installed on a host or virtual machine.
8. Use the Email Priority drop-down list to set or modify email as a primary, secondary, or
tertiary transport mechanism.
Specifying disabled removes email as a transport mechanism.
9. In the Email-SMTP field, type the fully qualified domain name or IP address of the primary
email server. You cannot enter more than 63 characters.
10. In the Subject field, set or modify the subject of the email message. You cannot enter
more than 127 characters.
11. In the Recipient Address (es) field, set or modify the destination email addresses that
receive event files. You cannot enter more than 255 characters.
Change the ConnectHome settings
103
Manage logging and alerting capabilities
Note: EMC recommends that you do not change the default EMC recipient address
emailalert@emc.com unless otherwise specified by your authorized service provider.
12. In the Sender Email Address field, accept or modify the sender email address.
It is important to note that email can be forwarded through your email server. In this case,
the Email server will require a valid mail user.
13. Under FTP, use the FTP Priority drop-down list to set or modify FTP as a primary,
secondary, or tertiary transport mechanism.
Specifying disabled removes FTP as a transport mechanism.
14. In the FTP Server field, type the IP address of the ESRS Gateway FTP server. This is
where event files will be transferred.
15. In the FTP Port field, set or modify the corresponding primary FTP port.
16. In the User Name field, set or modify the username of the login account on the primary
FTP server. You cannot enter more than 15 characters.
17. In the Password field, set or modify the password of the login account on the primary
FTP server. You cannot enter more than 15 characters.
18. In the Remote Location field, set or modify the remote directory path on the FTP server
where event files will be deposited. You cannot enter more than 63 characters.
19. In the Transfer Mode field, set or modify the transfer mode of the primary FTP transport
mechanism.
20. Use the Modem Priority drop-down list to set or modify the modem as a primary,
secondary, or tertiary transport mechanism.
If there is no modem, select Disabled.
21. By default, the modem uses a dialing prefix of 9 to get an outside line, and then dials a
1-800 number. You do not need to change the number in the Number to Dial Out field if
you are configuring Connect Home on a system in the US or Canada.
Note: Review the list of International toll-free numbers on page 108 if you are configuring Connect
Home on a system outside of the US or Canada.
22. Use the Monitoring Station HTTPS Priority drop-down list to set or modify the monitoring
station server as a primary, secondary, or tertiary transport mechanism.
104
System Operations
Manage logging and alerting capabilities
This selection refers to using the ESRS IP Client for VNX software which is not included
as part of the VNX OE. The ESRS IP Client for VNX software must be installed on a host
or virtual machine and should not be used in conjunction with the ESRS software on the
Control Station that is included as part of the VNX OE.
23. Use the URL to set or modify the URL of the monitoring station server. IPv4 and IPv6
addresses can be used in the URL.
An IPv6 address must be in the following format:
https://[<IPv6-address>]:<port>/<directory>
where
<IPv6-address> = IPv6 address
<port> = port number
<directory> = target directory
24. Click Apply.
After you finish
Configuring Events and Notifications on VNX for File provides more information about events
that cause the VNX system to connect home.
Provision ESRS
Before you begin
EMC Secure Remote Support (ESRS) depends on the DNS setting on the Control Station.
To function properly, the VNX system must be configured with at least one DNS Server.
Procedure
To provision ESRS, you must be logged in with root privileges.
1. Ensure that a DNS Server is configured.
To view and, if necessary, add a DNS Server to the DNS configuration settings, select
All Systems > Domains, and from the Local Domain task list, click Configure DNS.
Alternatively, select the system, and then select Settings, and from the Network Settings
task list, click Configure DNS. DNS Configuration for Storage Domain appears. See Add
DNS Server on page 96 for more information about adding a DNS Server.
2. Select System.
3. From the task list, under Service Tasks, select Manage EMC Secure Remote Support.
Change the ConnectHome settings
105
Manage logging and alerting capabilities
For a VNX with two Control Stations, a dialog box for selecting the target Control Station
(Primary or Standby) appears first. The Primary Control Station will be selected by default.
If necessary, change the selection and click Continue to navigate to the Manage ESRS
page for the corresponding Control Station.
As an alternate method to access the ESRS parameters, under Service Tasks, select
Manage Connect Home and click Manage ESRS Settings in the ESRS Priority field. This
link navigates directly to the Manage ESRS page for the primary Control Station. To
manage the ESRS on a standby Control Station, you must select Manage EMC Secure
Remote Support from the task list under Service Tasks.
4. Select either EMC Online Support (Powerlink) or RSA SecurID for the Type credential.
The EMC support credentials are required for ESRS.
If you select RSA SecurID, be aware that the SecurID is valid for only 60 seconds. The
SecurID password may expire while you fill in the remaining fields.
5. Type the user name for the User Name credential.
6. Type the password for the Password credential.
7. If a Proxy Server will be used in the ESRS configuration, select the checkbox to the right
of Use Proxy Server for ESRS.
The fields related to the Proxy Server appear.
8. Select either HTTP or SOCKS for the Protocol field.
9. Type the IP address of the Proxy Server in the Proxy Address field.
10. Type the port number to use for the Proxy Server in the Port field.
11. If credentials are required for the Proxy Server, select the checkbox to the right of Need
Credentials.
When the credentials for the Proxy Server are required they must be provided; otherwise,
the Proxy Server may fail to connect to the ESRS server.
12. Type the user name for the User Name credential.
13. Type the password for the Password credential.
14. If a Policy Manager will be used in the ESRS configuration, select the checkbox to the
right of Use Policy Manager for ESRS.
The fields related to the Policy Manager appear.
106
System Operations
Manage logging and alerting capabilities
15. If SSL protocol will be used for the Policy Manager, select the checkbox to the right of
Is Secure.
16. Type the IP address of the Policy Manager in the Address field.
17. Type the port number to use for the Policy Manager in the Port field.
18. If a Proxy Server will be used for the Policy Manager, select the checkbox to the right of
Use Proxy Server.
19. Select either HTTP or SOCKS for the Protocol field.
20. Type the IP address of the Proxy Server in the Proxy Address field.
21. Type the port number to use for the Proxy Server in the Proxy Port field.
22. If credentials are required for the Proxy Server, select the checkbox to the right of Need
Credentials.
When the credentials for the Policy Manager Proxy Server are required they must be
provided; otherwise, the Proxy Server may fail to connect to the Policy Manager.
23. Type the user name for the User Name credential.
24. Type the password for the Password credential.
25. Click OK to save the ESRS configuration.
Re-provision ESRS
Before you begin
EMC Secure Remote Support (ESRS) must be provisioned completely and enabled before
you can re-provision the ESRS.
Procedure
To re-provision ESRS, you must be logged in with root privileges.
1. Select System.
2. From the task list, under Service Tasks, select Manage EMC Secure Remote Support.
For a VNX with two Control Stations, a dialog box for selecting the target Control Station
(Primary or Standby) appears first. The Primary Control Station will be selected by default.
If necessary, change the selection and click Continue to navigate to the Manage ESRS
page for the corresponding Control Station.
Change the ConnectHome settings
107
Manage logging and alerting capabilities
As an alternate method to access the provisioned ESRS parameters, under Service
Tasks, select Manage Connect Home and click Manage ESRS Settings in the ESRS Priority
field.This link navigates directly to the Manage ESRS page for the primary Control Station.
To manage the ESRS on a standby Control Station, you must select Manage EMC Secure
Remote Support from the task list under Service Tasks.
3. Click the check box to the right of Re-provision.
4. Select either EMC Online Support (Powerlink) or RSA SecurID for the Type credential.
The EMC support credentials are required for ESRS.
If you select RSA SecurID, be aware that the SecurID is valid for only 60 seconds. The
SecurID password may expire while you fill in the remaining fields.
5. Type the user name for the User Name credential.
6. Type the password for the Password credential.
7. Make any necessary changes to the Proxy Server or Policy Manager parameters.
To add a Proxy Server, you must select the check box to the right of Use Proxy Server
for ESRS and provision the related fields. To change existing Proxy Server information,
you must unselect then select the check box to the right of Use Proxy Server for ESRS
and re-provision the related fields.
8. Click OK to save the changes.
International toll-free numbers
The Connect Home dialing configuration must change if any of the following were to apply:
108
◆
If the customer is outside the U.S. or Canada, refer to the list of international toll-free
numbers.
◆
If the customer-supplied telephone line does not use the prefix 9 to reach an outside line,
change the dialing prefix.
◆
If the customer is located in a country that does not use the U.S.-style dial tone, such as
Germany, disable dial tone detection on the modem.
◆
If the customer has an MT5634ZBA modem (check the label on the bottom of the modem
or on the box that the modem shipped in), you might need to run a special utility to set
the correct country/regional code.
System Operations
Manage logging and alerting capabilities
Table 2. International toll-free numbers
Country
AT&T 1800
MCI
Argentina
0800-444-0932
0-800-3330327
Australia (AU)
10800-150-072
1-800-1-48291
Austria
0800-200-288
0800-292575
866-285-3258
Bahamas
1-866-282-3258
Bahrain
8000-960
Belgium (BG)
0800-7-2692
0800-78824
Brazil (BZ)
000811-005-9773
0800-891-0678
Chile (CH)
1230-020-0133
123-0-020-2855
China (Netcom Group) (CI)
10-800-711-0288
10-800-712-0654
China (Telecom South) (CI)
10-800-110-0288
10-800-120-0654
Colombia (CL)
980912-1659
01800-9-155034
Costa Rica (CR)
0-800-011-0794
0800-012-0994
Czech Republic
800-142-409
Denmark (DK)
80-884824
80-883573
Dominican Republic (DR)
1-866-285-3258
1-888-156-1787
Finland (FI)
08001-1-7491
0-800-1-19810
France (FR)
0800-90-7131
0800-908817
Germany (GE)
0800-182-7792
0800-1009325
Greece (GR)
00-800-11-005-9773
00800-12-5546
Guam (U.S. Trust Territory)
1-866-285-3258
Guanya
1-8662216493
1-866-820-7113
Change the ConnectHome settings
109
Manage logging and alerting capabilities
Table 2. International toll-free numbers (continued)
Country
AT&T 1800
Hong Kong (HK)
800-96-6548
800-900982
Hungary (HU)
06-800-12-038
06-800-14445
Indonesia (IO)
001-803-1-005-9773
001-803-011-2869
Ireland (IR)
1-800-55-3878
1-800-55-7532
Israel (IS)
1-800-941-9773
1-800-930-3020
Italy (IT)
800-783283
800-782106
Japan (JP)
00531-11-5188
00531-1-20466
Korea (KO)
00798-1-1-005-9773
00798-14-800-5139
Lativa (LV)
800-0013
Luxembourg (LX)
800-23011
8002-9833
Malaysia
1-800-80-5830
1-800-8-04295
Mexico (MX)
001-866-285-3258
001-8663644901
Netherlands (NL)
0800-023-2361
0800-0224963
New Zealand (NZ)
0800-103519
0800-446336
Nicaragua (NI)
001-800-2201512
Norway (NW)
800-15798
800-12660
Peru
0800-50997
0800-51592
Philippines (PH)
1-800-1-111-0841
1-800-1-114-1093
Poland (PD)
0-0-800-111-1422
00-800-1112812
Portugal (PO)
800-8-11028
800-8-12381
Russia (RU)
110
MCI
System Operations
8-10-8002-3153011 OR
8-10-8022-1523011
Manage logging and alerting capabilities
Table 2. International toll-free numbers (continued)
Country
AT&T 1800
MCI
Singapore (SI)
800-110-1285
800-1203666
South Africa
0800-990-808
080-09-99955
Spain (SP)
900-95-1215
900-961845
Sweden (SW)
020-79-0950
020-79-6581
Switzerland (SZ)
0800-56-4581
0800-835421
Taiwan (TW)
0080-10-3965
00801-13-7087
Thailand (TH)
001800-11-005-9773
001-800-12-066-3916
Turkey (TU)
00-800-13-005-9773
00-800-151-0964
UK
0800-028-7702
08-001696651
Uruguay (UR)
000-411-005-9773
000-413-598-2665
United States
866-285-3258
800-527-0941
Venezuela
0800-1-00-2043
0800-1-00-2404
Set the country code on the MT5634ZBA modem
If the customer has a MT5634ZBA modem (check the label on the bottom of the modem or
on the box that the modem shipped in) you might need to run a special utility to set the
correct country or regional code. The modem ships with a default value for the country or
regional code. The default value might not be appropriate for the location of the system.
Manual instructions for setting the country code on page 112 provides more information if
your service laptop is not a Microsoft Windows-based PC. If your service laptop is a Microsoft
Windows-based PC, then the procedure explained in the Windows-based PC instructions
that follow has more information.
Note: If you need to verify the country or regional code that is configured on the modem, you must use
the manual instructions.
1. Download the latest version of the ZBAWizard.exe utility:
Set the country code on the MT5634ZBA modem
111
Manage logging and alerting capabilities
a. In a web browser on your service laptop go to the Global Services website:
http://www.cs.isus.EMC.com/
b. Click the Application Download Area hyperlink.
c. Click the ZBA Global Modem Wizard hyperlink.
d. Click the ZBAWizard.exe hyperlink to download the executable.
e. Click Save and select a location on your service laptop to save the file. This application
will be run at a later step in the procedure, so ensure that you know where the file is.
2. Connect the serial cable from the modem to your service laptop.
Note: Ensure that the modem is powered on.
3. Using Windows Explorer on your service laptop, double-click the ZBAWizard.exe file. A
password prompt appears.
4. Type EMC (case-sensitive) and click OK when prompted for the decryption password.
The Global Wizard application appears, as displayed.
5. Click Next to begin the wizard. The wizard will now try to contact the modem. Wait for
modem detection. If this does not occur, verify that the modem is powered on and the
serial cable is securely connected at both ends.
6. Click Next when the modem is found.
7. If the following message appears, click OK to acknowledge the message.
8. Select or verify that the correct country or region is selected, as displayed. Click Next. A
confirmation screen appears with your selection.
9. Click Next on the confirmation screen.
10. Click Finish to exit the wizard. This completes the procedure.
Manual instructions for setting the country code
To manually set the country or region code without ZBAWizard.exe:
1. Connect the serial cable from the modem to your service laptop.
Note: Ensure that the modem is powered on.
112
System Operations
Manage logging and alerting capabilities
2. Open a terminal emulator session by using the following settings:
◆
19200 bits per second
◆
8 data bits
◆
parity None
◆
1 stop bit
◆
flow control None
◆
Set terminal emulation to ANSI. Typically this is done by using COM 1
3. Type the following command to check the current country or regional setting:
ATI9
9
The decimal value associated with the country or region code is output to the terminal
emulator session. Table 3 on page 114 details the list of countries and their decimal values.
For example:
+++
+ ATI9
952
2(?$MTS00C1\\MODEM\TIA0602,TIA0578\MultiTech Systems MT5634ZBAV92A9)
OK
4. If the country or region code needs to be changed, type the following command:
AT%T19,0,<modem_hex_value>
where <modem_hex_value> is the hex value for the country or region code. Table 3 on
page 114 provides more information.
For example:
AT%T19,0,1
1OK
5. Type the following command to confirm that the current country or regional setting was
changed correctly:
ATI9
The decimal value associated with the country or region code is output to the terminal
emulator session. Table 3 on page 114 details the list of countries and their decimal values.
This completes the procedure.
Set the country code on the MT5634ZBA modem
113
Manage logging and alerting capabilities
Table 3. MT5634ZBA modem country/region codes
114
Country
Region config. command (Hex)
ATI9 result code (Decimal)
Australia
AT%T19,0,1
1
Hong Kong, Hungary, India, Indonesia, AT%T19,0,30
Israel, Korea, Malaysia, Republic of
Korea, Philippines, Poland, Singapore,
Slovenia, Vietnam
48
Japan
AT%T19,0,10
16
New Zealand
AT%T19,0,9
9
South Africa
AT%T19,0,35
53
Afghanistan, Albania, Algeria, Ameri- AT%T19,0,34
can Samoa, Andorra, Angola, Anguilla,
Antigua and Barbuda, Argentina, Armenia, Aruba, Austria, Azerbaijan,
Bahamas, Bahrain, Bangladesh, Barbados, Belarus, Belgium, Belize,
Benin, Bermuda, Bhutan, Bolivia,
Bosnia and Herzegovina, Botswana,
Brazil, Brunei Darussalam, Bulgaria,
Burkina Faso, Burundi, Cambodia,
Cameroon, Canada, Canary Islands,
Cape Verde, Cayman Islands, Central
African Republic, Chad, Chile, China,
Colombia, Congo, The Democratic
Republic of Congo,Cook Islands,
Costa Rica, Côte D'Ivoire, Croatia,
Cyprus, Czech Republic, Denmark,
Djibouti, Dominica, Dominican Republic
52
System Operations
Manage logging and alerting capabilities
Table 3. MT5634ZBA modem country/region codes (continued)
Country
Region config. command (Hex)
ATI9 result code (Decimal)
East Timor, Ecuador, Egypt, El Sal- AT%T19,0,34
vador, Equatorial Guinea, Estonia,
Ethiopia, Faero Islands, Fiji, Finland,
France, French Guiana, French Polynesia, Gabon, Gambia, Georgia, Germany, Ghana,Gibraltar, Greece,
Greenland, Grenada, Guadeloupe,
Guam, Guatemala, Guernsey, C.I.,
Guinea, Guinea-Bissau, Guyana, Haiti,
Holy See (Vatican City State), Honduras, Iceland, Iran, Iraq, Ireland, Isle
of Man, Italy, Jamaica, Jersey C.I.,
Jordan, Kazakhstan, Kenya, Kiribati,
Kuwait, Kyrgyzstan, Lao People's
Democratic Republic, Latvia, Lebanon,
Liberia, Libya, Liechtenstein, Lithuania, Luxembourg, Macau, Macedonia,
The Former Yugoslav Republic of,
Madagascar, Malawi, Maldives, Mali,
Malta, Martinique, Mauritania, Mauritius, Mayotte, Mexico, Moldova, Republic of Monaco, Mongolia, Montserrat,
Morocco, Mozambique
52
Namibia, Nauru, Nepal, Netherlands, AT%T19,0,34
Netherlands Antilles, New Caledonia,
Nicaragua, Niger, Nigeria, Norway,
Oman, Pakistan, Palestine Territory,
Occupied, Panama, Papua New
Guinea, Paraguay, Peru, Portugal,
Puerto Rico, Qatar, Reunion, Romania, Russian Federation, Rwanda,
Saint Kitts and Nevis, Saint Lucia,
Saint Vincent and the Grenadines,
Samoa, Saudi Arabia, Senegal, Seychelles, Sierra Leone, Slovakia,
Solomon Islands, Spain, Sri Lanka,
Sudan, Surinam, Swaziland, Sweden,
Switzerland, Syrian Arab Republic,
Taiwan, Tajikistan, Tanzania, United
Republic of, Thailand, Tahiti, Togo,
Tonga, Trinidad and Tobago, Tunisia,
Turkey, Turkmenistan, Turks and
Caicos Islands, Uganda, Ukraine,
United Arab Emirates, United Kingdom, Uruguay, USA, Uzbekistan,
Vanuatu, Venezuela, Virgin Islands,
British, Virgin Islands, Yemen, Yugoslavia, Zambia, Zimbabwe
52
Set the country code on the MT5634ZBA modem
115
Manage logging and alerting capabilities
Interpret log files
Log files contain messages to assist you in determining what is happening with the VNX.
Some logs have information about the state of the VNX, while others have information about
errors. The system log (sys_log) must be viewed using the nas_logviewer command when
viewing the log from the CLI.
◆
Location of VNX logs on page 116
◆
Read log messages on page 117
Location of VNX logs
Table 4 on page 116 provides a complete list of VNX File logs.
Note: To view VNX logs located in the /nas/log directory, use the nas_logviewer command to
format and view these log files.
For example, to view the last 50 entries to the /nas/log/sys_log file tersely formatted, use the
logviewer command in the following manner:
$ /nas_logviewer -t /nas/log/sys_log|tail -50
Table 4. VNX log files
Log
Command line or log location
Description
Command
$ /nas/log/cmd_log
Displays a list of all successful commands executed for the VNX File. Commands displaying information only and most commands in the /nas/sbin directory are not logged.
Command error
$ /nas/log/cmd_log.err
Lists all the failed commands issued by the administrator. Commands displaying information only
and most commands in the /nas/sbin directory are
not logged.
Data Mover
$ server_log <movername>
Displays the current log updates from the most
recent restart.
Data Mover
$ server_log <movername> -a
Displays the available history of logs for a Data
Mover.
Note: Use the -s option to display logs with a userfriendly timestamp.
116
System Operations
Manage logging and alerting capabilities
Table 4. VNX log files (continued)
Log
Command line or log location
Description
System
$ /nas/log/sys_log
Displays a cumulative list of system event and log
messages from the most recent Control Station
restarts.
Note: Use this command to format system logs:
nas_logviewer -f
/nas/log/sys_log
OS system
$ /nas/log/osmlog
Lists events related to the Control Station operating-system operation.
ConnectHome
$ /nas/log/ConnectHome
Stores each CallHome pending in XML format.
SIB POST
$ /nas/log/sibpost_log
Displays results from Control Station hardware
tests performed at boot time.
EMC
$ /nas/log/symapi.log
Symmetrix㍷ API
Installation and
upgrade
Lists events from the SYMAPI layer generated as
the VNX File interacts with an attached Symmetrix
system. The Symmetrix documentation provides
more information about these messages.
$ /nas/log/instcli.log
Stores log SYMCLI installation.
$ /nas/log/install.
<NAS_Code_Version>.log
NAS code installations and upgrades.
$ /nas/log/upgrade.
<NAS_Code_Version>.log
Read log messages
Each type of log has a slightly different format. This section explains the formats by displaying
a line of the log with an explanation of the component parts.
Server log
Example:
2012-03-15 04:38:04: ADMIN: 4: Command succeeded: logsys add output>
disk=root_log_2 bufsz=256
Table 5 on page 118 provides a complete list of Server log components using the example
shown above.
Interpret log files
117
Manage logging and alerting capabilities
Table 5. Server log components
Log component
Description
Example
Date
Displays the date.
2012-03-15
Time
Displays the time.
04:38:04
Category
Lists the part of the VNX File where
the error originates.
ADMIN
Table 7 on page 119 provides a complete list of categories.
Severity level
Indicates the importance of the event. 4
Values can be 0 through 7, with 0 indicating the highest level of importance.
Table 6 on page 118 describes these
levels.
The default severity for each module
is set to 4. Whenever the Data Mover
tries to generate a log message, it
provides the log severity level and the
module name. If the given severity is
less than or equal to the current
severity level for the given module, the
message goes to server log; otherwise, it is ignored.
Message text
Command succeeded:
The log message.
logsys add output>
disk=root_log_2
bufsz=256
Table 6 on page 118 provides a complete list of server log and system log severity levels.
Table 6. Server log and system log severity levels
118
Severi- Meaning
ty level
Severity Meaning
level
0
Emergency
4
Warning
1
Alert
5
Notice
2
Critical
6
Info
3
Error
7
Debug
System Operations
Manage logging and alerting capabilities
Table 7 on page 119 provides a list of server message category types.
Table 7. Server log message category
Category
Explanation
Category
ADMIN
Status of commands issued to the VNX File PAX
Portable Archive Exchange for backup
BOOT
CPU boot
RCPD
VNX Replicator remote copy daemon messages
CAM
Common Access Method layer, typically
storage-system related
RPC
Remote Procedure Call
CFS
Common File System, generic file system
information, not specific to UxFS
SECURITY
Security messages
CVFS
Checkpoint Virtual File System
SHADOW
Shadow directory messages
DRIVERS
Device driver messages (for example, SCSI, SMB
Fibre Channel, NIC)
FMP and
MPFS
MPFS server and file system
STORAGE Similar to CAM — messages related to the
and CHAMII storage system storage devices
FSTOOLS
File system monitoring
SVFS
EMC SnapSure㍷ checkpoint activity
FTPD
FTP daemon
SYSTEM
Environment monitor-related messages (for
example, SIB attention status and bit errors)
HTTPD
HTTP daemon
TCP
TCP layer messages
IP
Internet Protocol (IP) layer messages (for
example, address block allocation/release
and route changes)
TIMESRVC Time service activity messages (for example, NTP)
KERBEROS
Kerberos-related messages (for example,
domain join)
UDP
User Datagram Protocol
KERNEL
Data Mover motherboard and BIOS messages
UFS
File system messages
LDAP
Lightweight Directory Access Protocol-relat- VC
ed messages
Antivirus-checking related
LIB
Library-related messages
Data Mover version
LOCK
Lock manager messages (for example, statd VMCAST
for NFS)
EMC VNX Replicator volume multicasting
MGFS
Migration File System
VNX Replicator
NDMP
Network Data Management Protocol informa- XLT
tion
VERSION
VRPL
Explanation
CIFS services
I18N or Unicode messages
Interpret log files
119
Manage logging and alerting capabilities
Table 7. Server log message category (continued)
Category
Explanation
Category
NFS
NFS information (for example, exports and
cache activity)
Explanation
System log
Table 8 on page 120 provides a complete list of system log components.
Example:
Jun 24 10:39:46 2011 BoxMonitor:2:101 Slot 1 reason code of 0 is stale
Table 8. System log components
Log component
Description
Example
Date and time
Displays the date and time.
Jun 24 10:39:46 2011
Facility
Identifies the part of the system gener- BoxMonitor
ating the message text.
Severity level
Indicates the importance of the event. 2
Values can be 0 through 7, with 0 indicating the highest level of importance.
Table 6 on page 118 describes these
levels.
Event ID
Identifies the event associated with
101
the facility. EMC VNX Command Line
Interface Reference for File provides
more details on the nas_event command.
Event text
Displays the log message.
Slot 1 reason code of 0 is stale
Some of the facilities that generate messages are explained inTable 9 on page 120.
Table 9. System log facilities
120
Facility
Description
BoxMonitor
Monitors hardware components presence, interrupts, and alarms.
MasterControl
Monitors required system processes.
System Operations
Manage logging and alerting capabilities
Table 9. System log facilities (continued)
Facility
Description
CallHome
Contains messages related to the
CallHome feature.
Command log and command error log
Example:
2005-03-15 09:52:36.075 db:0:9558:S: /nas/bin/nas_acl -n nasadmin -c -u
201 level=2
2005-03-15 10:46:31.469 server_2:0:26007:E: /nas/bin/server_file
server_2
-get group /nas/server/slot_2/group.nbk: No such file or directory
Table 10 on page 121 lists the command log components using the example shown above.
Table 10. Command log components
Log component
Description
Example
Date
Displays the date.
2005-03-15
Time
Displays the time.
09:52:36.075
Source
Indicates where the command or error originates.
db
User ID
Indicates the user who issued the command.
0
Note:
◆ 0=root
◆ 201=nasadmin
Process ID
A system-generated identifier.
9558
Beginning and end markers Displays the beginning (S) and end (E) of the
command. If there is not an S and E pair, the
command did not complete.
S
Message text
/nas/bin/nas_acl -n nasadmin -c -u 201
The command log displays commands.
The command error log displays the command
and the error.
Interpret log files
121
Manage logging and alerting capabilities
VNX and RSA Envision
To make VNX storage systems even more secure, they also leverage the continuous
collecting, monitoring, and analyzing capabilities of RSA enVision. RSA enVision performs
the following functions:
◆
Collects logs - Collects event log data from over 130 event sources - from firewalls to
databases. RSA enVision can also collect data from custom, proprietary sources using
standard transports such as Syslog, OBDC, SNMP, SFTP, OPSEC, or WMI.
◆
Securely stores logs - Compresses and encrypts log data so that it can be stored for later
analysis, while maintaining log confidentiality and integrity.
◆
Analyzes logs - Analyzes data in real time to check for anomalous behavior that requires
an immediate alert and response. The RSA enVision proprietary logs are also optimized
for later reporting and forensic analysis. Built-in reports and alerts allow administrators
and auditors quick and easy access to log data that is easy to understand.
RSA enVision collects and analyzes administrative events logged by VNX storage systems,
and creates logs of this information that it stores on the VNX storage system. This gives
auditors easy access to scheduled and unscheduled reports about administrative events
that occurred on VNX storage systems; the auditor does not have to access the actual device
itself or have knowledge of VNX administrative applications. Specific use cases include:
122
◆
Providing an audit trail for making copies of data
◆
Alerting and reporting when replication services malfunction
◆
Creating reports on daily device configuration changes
◆
Creating alerts and reports about user actions
◆
Creating alerts about disks that are removed
System Operations
Manage logging and alerting capabilities
NAS or SAN environment rules
When you connect a SAN configuration to the VNX, you create a NAS or SAN configuration.
A NAS or SAN configuration has rules for RAID types, LUN allocation, and array read or
write cache settings that you must consider. Table 11 on page 123 lists these considerations.
If needed, contact the EMC Customer Support or your service provider for help with template
selection. The EMC E-LabTM Interoperability Navigator explains how to configure CLARiiON
CX, CLARiiON CX3, CLARiiON CX4, VNX for Block storage arrays by using predefined
templates and is available at http://Support.EMC.com.
After logging in, go to Support ➤ Interoperability and Product Lifecycle Information ➤ E-Lab
Interoperability Navigator.
Note: The E-Lab Interoperability Navigator provides information on supported NAS or SAN environments.
Table 11. VNX File/VNX for Block NAS and SAN environment considerations
Category
Considerations
RAID types
◆
For detailed information about RAID types and LUN usages see the EMC Unified Storage
Best Practices for Performance and Availability Common Platform and Block Storage 31.0:
Applied Best Practices found on Powerlink.
◆
The Vault drives containing the VNX control LUNs uses about 192 GB of their per-drive capacity for system files. The portion of the drives not used for the system files is user configurable.
A RAID group for traditional LUNs may be created there. To provision system drives for the
highest usable capacity they can be configured as a four drive RAID level 5 (3+1) and used
to host traditional LUNs.
◆
There are no RAID-type restrictions for LUNs on a SAN. RAID groups consisting of only SAN
LUNs might be configured with any number of disks supported by the VNX for Block system.
◆
On a single shelf, you can configure mixed RAID types.
NAS or SAN environment rules
123
Manage logging and alerting capabilities
Table 11. VNX File/VNX for Block NAS and SAN environment considerations (continued)
Category
Considerations
Allocation of LUNs
◆
The RAID group containing the VNX File control LUNs must be dedicated to NAS. No SAN
LUNs might reside on this RAID group. LUN numbers 0 to 15 are dedicated to VNX File control
LUNs.
Note: Any attempt to allocate storage in a LUN number between 0-15 will result in
Error 3147: volume <disk-id> resides on a reserved disk
. If a reserved disk is already used in an AVM storage pool, no additional storage will be allocated from the volume built on the reserved disk. This restriction affects only new space allocation. Existing file systems will continue to function normally. If you see this error, contact
your EMC Customer Support representative so corrective action can be taken.
◆
All other RAID groups are not restricted to all SAN or all NAS. The RAID group can be sliced
up into LUNs and distributed to either a SAN or NAS environment.
◆
RAID groups do not have to be split into two, four, or eight equal-size NAS LUNs, but they
must be balanced across the array. This means an equal number of same-size NAS LUNs
must be spread across storage processor (SP) A and SP B.
Note: If you do not configure the LUNs across SP A and SP B properly, you will not be able
to manage the LUNs by using the Unisphere software.
Array read/write
cache settings
For the VNX File with a VNX for block integrated array, set the read or write caches with the following
principle: the rule of the thumb is to allocate one third of memory for read cache and two thirds for
write cache (remember that read cache is for prefetch and that if data is in the write cache, it is
read from cache, not from disk).
Note: For gateway servers, write cache is required. The VNX for Block documentation provides
more details on settings.
124
System Operations
Manage logging and alerting capabilities
Table 11. VNX File/VNX for Block NAS and SAN environment considerations (continued)
Category
Considerations
Standard parame- These parameters or settings must be enabled or disabled as follows:
ters and settings
when binding LUNs ◆ Enable write cache
◆
Enable read cache
◆
Disable auto-assign for each LUN
◆
Disable clariion no_tresspass
◆
Disable failovermode
◆
Disable arraycommpath
CAUTION To prevent file system corruption, the arraycommpath setting should not be
changed while the server is online.The server should be taken offline to change this setting.
EMC MirrorView㍷, VNX for block, MirrorView, SnapView, and SAN Copy are not supported on NAS-allocated LUNs.
EMC SnapView㍷,
and EMC
SAN Copy㍷
VNX for file problem information
For problems with Unisphere or the VNX for file, EMC recommends that before contacting
the service provider or EMC for help, you should run log collection promptly. The sooner
the collection script is run, the more likely that command output, logs, and dump files that
can help correct the problem can be collected.
The tasks for collecting problem information are:
◆
Enable Automatic Log Transfer from Unisphere on page 127
◆
Run Log Collection from the CLI on page 127
Use CLI options to perform script operations on page 130 details the command options
available to perform script operations for VNX for file.
Automatically collect and transfer logs
The Automatic Collection and Transfer tool aids in troubleshooting and resolving system
errors and other problems with a VNX for file that is configured to issue a call home. When
VNX for file services are running, the collection script runs automatically in the background
on the Control Station. It collects and saves command output, logs, and dump files related
VNX for file problem information
125
Manage logging and alerting capabilities
to events that produce a CallHome. Examples of such events include Data Mover panics
and Replication session failures. If you enable Automatic Transfer, the Control Station
automatically transfers this information to a preconfigured FTP server when it is generated.
Note: As the script does not run during system installations and upgrades, it does not collect events
that might occur during those operations.
The tool produces zipped archive files of logs needed to analyze issues, and writes these
files to /nas/var/emcsupport. This tool also collects Data Mover panic dumps when they
occur with support materials. The Data Mover panic dumps are stored in the directory
/nas/var/dump. After collecting logs and files, if the transfer script is enabled, the tool
automatically transfers the collected data to EMC by using the configured transport mode
(such as Monitoring Station HTTPS). By default, the transfer capability is disabled.
A maximum of 460 MB is used for archiving log collections and a maximum of two Data
Mover panic dumps. If the logs and dumps specified in the configuration file have reached
the maximum, the tool deletes the oldest log to make room for new logs. However, the tool
leaves old dumps in place, so those have to be manually deleted from the dump directory.
When the tool successfully transfers a Data Mover panic dump to /nas/var/dump, it
automatically clears the dump partition. If two dumps already exist in the dump area, the
tool logs a message to sys_log, indicating that it cannot extract any further dumps to
/nas/var/dump until unneeded dumps are manually deleted.
The system logs contain entries each time a dump is transferred by the configured transport
mode to EMC Customer Service. If the tool is invoked manually, the command output and
any other important messages are logged in /nas/log/sys_log.
Note: If the configuration file has used the entire serial number string to identify dumps, the location
of the dump transfer might be truncated in sys_log. If this occurs, even though the system log might
not report the complete transfer location, the transfer is successful, as recorded in the log. Administrator
or root user privileges are needed to invoke the Automatic Collection and Transfer tool, which is run
from the command line interface (CLI). You also might be asked by an EMC Customer Support
Representative to run the tool to diagnose and solve system problems.
Configuration file
The first time the master script runs, it creates the configuration file
/nas/site/automaticcollection.cfg. This file contains lines that set various parameters to
manage the collection and transfer processes. For instance, it determines the location from
which the files are transferred, and, in the case of FTP as the configured transport mode, it
automatically sets the username and password for transfer files if the automatic transfer
capability is enabled. If the configuration file is changed, the automatic collection script does
not re-create it. In this case, to return to the default configuration file, rename or remove the
edited configuration file from the system.
However, apart from disabling the tool or changing the part of the file related to the transport
mode configuration, EMC strongly recommends that you use the default values in this file.
126
System Operations
Manage logging and alerting capabilities
Otherwise, it is possible that the tool could consume more Control Station resources than
are necessary.
The configuration file manages the following information:
◆
Whether to disable the automatic transfer capability.
◆
The number of dumps to retain in the /nas/var/dump directory. The default is 2.
◆
Indicates the current version of the tool.
◆
The number of simultaneous transfers allowed from the Control Station. The default is
2.
◆
The host IP address or URL for the configured transport mode of files.
◆
For FTP as the configured transport mode, the username and password of the
administrator responsible for using the tool to transfer the files manually.
◆
For FTP as the configured transport mode, the remote directory for the FTP of files.
Enable Automatic Log Transfer from Unisphere
The Automatic Log Transfer tool is a support feature in VNX for file. Log Collection is enabled
by default. The system automatically collects and compresses logs and dumps when certain
events are generated. Support materials, logs, and dumps are saved locally on the Control
Station. After collecting logs and files, you can configure the system to automatically transfer
the collected data to EMC. The Automatic Transfer option is disabled by default. When you
enable Automatic Transfer, the system will automatically transfer the support materials
collected—both logs and dumps—from the Control Station to a pre-configured transport
mode, such as FTP or Monitoring Station HTTPS.
To enable automatic transfer:
1. Select the system.
2. Under Service Tasks, select Automatic Log Transfer for File.
3. In the dialog box that appears, select Enable Automatic Transfer and click Apply.
Run Log Collection from the CLI
You might be asked by an EMC Customer Support Representative to run the automatic
collection script on the Control Station.
To run the log collection script to create the support materials file, perform the following:
1. Log in to the control station as nasadmin and then switch (su) to root.
2. To run the script, type the complete path:
VNX for file problem information
127
Manage logging and alerting capabilities
Select /nas/tools/automaticcollection -getlogs
3. The script compiles the VNX for file support information into a compressed file and saves
the file in the /nas/var/log directory. The file is given the name:
support_materials_<serial number>.<yymmdd_hhss>.zip
where:
<serial number>
<yymmdd_hhss>
= the serial number of the VNX for file.
= the date and the time the script was run.
After creating the support materials file, contact the service provider or the EMC Customer
Service Center for directions on how to deliver the file for analysis. Use CLI options to perform
script operations on page 130 describes how to use the CLI options to perform several script
operations.
Disable Automatic Collection and Transfer tool
To completely disable the Automatic Collection and Transfer tool, type:
$/nas/tools/automaticcollection -disable -all
An alternative method of disabling the entire tool is to edit the configuration file
/nas/site/automaticcollection.cfg using a text editor such as vi, and uncomment the line
containing the word OFF.
The following is an example of a configuration file output:
Output
[nasadmin@bulls-cs ~]$ cat /nas/site/automaticcollection.cfg
# This is the configuration file for automaticcollection.
# Anything after the # character on that line is ignored.
# lines are also ignored.
Blank
Whitespace at the begining and end of each
# line is also ignored.
# To get back to the default configuration file, simply remove this
128
System Operations
Manage logging and alerting capabilities
Output
# file (or rename it, of course), and a new one will be created the
# next time automaticcollection runs.
wish,
You may change this file if you
# and if you do so, automaticcollection will not recreate it.
# However, you will not receive any updates to this file should you
# choose to upgrade your control station software later.
# Don't modify the following line unless instructed by authorized
# service personnel.
# OFF
# Current version number
VERSION 2
# Uncomment the following line to disable the transfer feature.
# Disable
# Uncomment the following line to control the number of copies of
# panic dumps you would like to keep in /nas/var/dump directory.
# We strongly suggest to keep the default value.
The default is 2.
# MaxCopyDump 2
# Uncomment the following line to control the number of simultaneous
# transfer you will allow from the Control Station.
The default is
# 2, and it should not go any lower.
# MaxTransfer 2
# The following configurations are used by the transfer process.
# Please do not modify these unless instructed by authorized service
# personnel.
host ftp.emc.com
user anonymous
pass APM00055108049@emc.com
VNX for file problem information
129
Manage logging and alerting capabilities
Output
# Modify the following line to specify the remote directory where
# the materials should be stored.
The default is on the FTP server
# /incoming/APM00055108049 directory.
remote_directory /incoming/APM00055108049
Use CLI options to perform script operations
This section describes the available options, regardless of whether you invoke them yourself
or at the request of EMC Customer Service. You must have administrator privileges to use
this tool. Consequently, be sure to log in to the Control Station as nasadmin before using
this tool.
Command options
To display a list of Automatic Collection and Transfer tool command options, type:
$/nas/tools/automaticcollection -help
Table 12 on page 130 lists the Automatic Collection and Transfer tool’s command options
and descriptions.
Table 12. Automatic Collection and Transfer tool command options
130
Option
Description
-help
Displays the complete list of options.
-getlogs
Runs the collection script which, when complete, causes the
logs to be transferred if the transfer script is enabled.
-filename <filename>
Includes additional information, such as the case number, in the
filename.
-retrievedump
Extracts the most recent dump and then runs the transfer script
for dumps if the transfer script is enabled.
-slot
Indicates the number of the slot from which to retrieve the dump.
-local
Writes the dump to a local directory.
-transferlogs
Runs the transfer script for logs. The script reviews timestamps
on all collected logs in /nas/var/log and then transfers the most
recent set of logs in this partition.
System Operations
Manage logging and alerting capabilities
Table 12. Automatic Collection and Transfer tool command options (continued)
Option
Description
-config
Displays the current configuration.
-disable
Turns off the transfer script.
-enable
Turns on the transfer script.
-info
Checks the state of the transfer script.
User examples
The following examples describe the functions you are most likely to perform with the
Automatic Collection and Transfer tool:
◆
To enable automatic transfer of file logs and dumps to EMC Customer Service, at the
command prompt, type:
$/nas/tools/automaticcollection -enable
◆
To disable automatic transfer of log files and dumps if they have been previously enabled,
at the command prompt, type:
$/nas/tools/automaticcollection -disable
◆
To completely turn off the Automatic Collection and Transfer tool, at the command prompt,
type:
$/nas/tools/automaticcollection -disable -all
EMC Customer Service and support provider examples
The following examples describe the functions you might perform if asked to do so by EMC
Customer Service or an authorized support provider:
◆
To run the collection script for logs, at the command prompt, type:
$/nas/tools/automaticcollection -getlogs
◆
To run the transfer script for dumps, at the command prompt, type:
$/nas/tools/automaticcollection -retrievedump -slot <slot ID>
◆
To run the transfer script for logs, at the command prompt, type:
$/nas/tools/automaticcollection -transferlogs
◆
To display the current configuration, at the command prompt, type:
VNX for file problem information
131
Manage logging and alerting capabilities
$/nas/tools/automaticcollection -config
◆
To check the state of the transfer script, at the command prompt, type:
$/nas/tools/automaticcollection -info
132
System Operations
10
Troubleshooting
As part of an effort to continuously improve and enhance the performance
and capabilities of its product lines, EMC periodically releases new versions
of its hardware and software. Therefore, some functions described in this
document may not be supported by all versions of the software or hardware
currently in use. For the most up-to-date information on product features,
refer to your product release notes.
If a product does not function properly or does not function as described
in this document, contact your EMC Customer Support Representative.
Problem Resolution Roadmap for VNX contains additional information
about using EMC Online Support and resolving problems.
Topics included in this chapter are:
◆
◆
◆
◆
◆
◆
◆
EMC E-Lab Interoperability Navigator on page 134
Error messages on page 134
Error messages for Data Mover on page 134
EMC Training and Professional Services on page 135
Recovery after an VNX SP failure on page 135
Monitor system activity on page 136
System activity output on page 136
System Operations
133
Troubleshooting
EMC E-Lab Interoperability Navigator
The EMC E-Lab㍷ Interoperability Navigator is a searchable, web-based application that
provides access to EMC interoperability support matrices. It is available on EMC Online
Support at http://Support.EMC.com. After logging in, in the right pane under Product and
Support Tools, click E-Lab Navigator.
Error messages
All event, alert, and status messages provide detailed information and recommended actions
to help you troubleshoot the situation.
To view message details, use any of these methods:
◆
Unisphere software:
•
◆
CLI:
•
◆
Type nas_message -info <MessageID>, where <MessageID> is the message
identification number.
Celerra Error Messages Guide:
•
◆
Right-click an event, alert, or status message and select to view Event Details, Alert
Details, or Status Details.
Use this guide to locate information about messages that are in the earlier-release
message format.
EMC Online Support:
•
Use the text from the error message's brief description or the message's ID to search
the Knowledgebase on EMC Online Support. After logging in to EMC Online Support,
locate the applicable Support by Product page, and search for the error message.
Error messages for Data Mover
While using the system, various messages can appear indicating successful or unsuccessful
command execution. Error messages can appear when there is a fault in a command syntax
or a fault with the system. Normally, system messages are reported to the log files. Always
check the system log (sys_log), which is produced by server_log, and the command error
log (cmd_log.err) for message information. In some cases when a problem occurs, no
message appears. Instead, system actions occur, which in turn, might indicate a problem.
Table 13 on page 135 lists two examples that might occur with Data Movers.
134
System Operations
Troubleshooting
Error messages indicating a problem with a Data Mover might also appear in the system
log. Therefore, when troubleshooting, periodically check the log for the presence of certain
error messages. These error messages appear only in the system log and do not appear
on screen during an active session.
Table 13. Data Mover problems
Symptom
Probable cause
Solution
Data Mover repeatedly stops respond- Data Mover might have lost its connection either in its cabling or from the neting.
work; or it might be out of memory or
free space.
Restart the Data Mover and then check
free space and memory. If these appear
acceptable, verify that all cables are
secure. Then ping or view system uptime.
When attempting to view SCSI devices, Storage system is offline.
the system stops responding.
Verify the storage system is online, and
then retry.
EMC Training and Professional Services
EMC Customer Education courses help you learn how EMC storage products work together
within your environment to maximize your entire infrastructure investment. EMC Customer
Education features online and hands-on training in state-of-the-art labs conveniently located
throughout the world. EMC customer training courses are developed and delivered by EMC
experts. Go to EMC Online Support at http://Support.EMC.com for course and registration
information.
EMC Professional Services can help you implement your system efficiently. Consultants
evaluate your business, IT processes, and technology, and recommend ways that you can
leverage your information for the most benefit. From business plan to implementation, you
get the experience and expertise that you need without straining your IT staff or hiring and
training new personnel. Contact your EMC Customer Support Representative for more
information.
Recovery after an VNX SP failure
If a storage processor (SP) panics (software failure) or must be removed and replaced
(hardware failure), perform the following to get the SP back online after it restarts:
1. Determine if an SP failed over by using the following CLI command:
$ nas_storage -info -id=<storage_id>
If an SP failed over, its disk volumes were transferred to the other SP.
2. Transfer the disk volumes back to the default (owning) SP by using the command:
$ nas_storage -failback -id=<storage_id>
EMC Training and Professional Services
135
Troubleshooting
3. After the SP is backed up, restart any Data Mover that restarted while the SP was down.
A Data Mover that restarts while one SP is down runs with only a single I/O path, even
after both SPs are up again. If this single I/O path fails, the Data Mover panics. This step
avoids a Data Mover panic and maintains the server’s high-availability operation.
Monitor system activity
Table 14 on page 136 describes various statistical outputs to help you monitor system activity.
Table 14. System activity monitoring
Type of display
Output
Command line
Protocol
Packet statistics and connection statuses server_netstat <movername> -s -p {
tcp|udp|icmp|ip }
Routing table
Routing table statistics
server_netstat <movername> -r
Interface
Specific interface statistics
server_netstat <movername> -i
Active connections
TCP or UDP connections
server_netstat <movername> -p {
tcp|udp }
System
Threads information, memory status, and server_sysstat <movername>
CPU state
System activity output
The following sections display samples of the system activity output.
server_sysstats
Returns the operating system statistics for the specified Data Mover:
$ server_sysstat server_2
server_2 :
threads runnable = 2
threads blocked = 230
threads I/J/Z = 1
memoryfree(kB)=412359
cpu idle_% = 57
server_netstat
Retrieves the network statistics for the specified Data Mover. You can also retrieve the
information for the sockets, physical interfaces, and routing table. The following command
returns the network statistics for each protocol:
136
System Operations
Troubleshooting
$ server_netstat server_2 -s
ip:
***
1054053 total packets received
0 bad header checksums
0 with unknown protocol
9 fragments received
0 fragments dropped (dup or out of space)
0 fragments dropped after timeout
9 packets reassembled
2 packets forwarded
80824 packets not forwardable
80824 no routes
973235 packets delivered
493572 total packets sent
0 packets fragmented
0 packets not fragmentable
0 fragments created
icmp:
*****
0 calls to icmp_error
Output histogram:
echo reply: 260861
destination unreachable: 56
echo: 0
Input histogram:
echo reply: 0
destination unreachable: 0
routing redirect: 0
echo: 260861
time exceeded: 0
address mask request: 0260908 messages received
260917 messages sent
tcp:
****
123708 packets sent
23 data packets retransmitted
0 resets
118192 packets received
7 connection requests
14 connections lingered
udp:
****
0 incomplete headers
249390 bad ports
345047 input packets delivered
98126 packets sent
You can also retrieve routing table and interface information, as displayed in the next
two commands:
$ server_netstat server_2 -r
System activity output
137
Troubleshooting
Destination
Gateway
Mask
Type
Proto
Interface
*******************************************************************************
0.0.0.0
10.245.56.1
0.0.0.0
DIRECT
LOCAL
cge-1-0
10.245.56.0
10.245.56.22
255.255.252.0
DIRECT
LOCAL
cge-1-0
128.221.252.0
128.221.252.2
255.255.255.0
DIRECT
LOCAL
mge0
128.221.253.0
128.221.253.2
255.255.255.0
DIRECT
LOCAL
mge1
Gateway
Type
Proto
Metric
IsValid Interface VLAN
******************************************************************************************************
::1
LOCAL
LOCAL
4294967295
true
$ server_netstat server_2 -i
Name
Mtu
Ibytes
Ierror Obytes
Oerror PhysAddr
****************************************************************************
cge-1-0 9000 1765361334
0
381528
0
0:60:48:1b:eb:86
cge-1-1 9000 0
0
0
0
0:60:48:1b:eb:87
cge-1-2 9000 0
0
0
0
0:60:48:1b:eb:98
cge-1-3 9000 0
0
0
0
0:60:48:1b:eb:99
mge0
1500 3866349266
0
3524897336
0
0:60:16:37:c:af
mge1
1500 2323210584
0
3983756798
0
0:60:16:37:c:ae
server_stats
server_stats provides real-time statistics for the specified Data Mover. Statistics are
displayed in a time-series fashion at the end of each interval. The statistics are organized
as a hierarchy of families that replaces the summary and table collections. Previously
defined summary and table collections have been converted to system-defined statistics
groups that can be used as arguments with the new - monitor option:
Table 15. Sample of Statistics Group names
138
System-defined Statistics Group
name
server_stats collection name
basic-std
-summary basic
caches-std
-summary caches
cifs-std
-summary cifs
nfs-std
-summary nfs
cifsOps-std
-table cifs
System Operations
Troubleshooting
Table 15. Sample of Statistics Group names (continued)
System-defined Statistics Group
name
server_stats collection name
diskVolumes-std
-table dvol
Statistics Groups are managed by the newly available nas_stats command.
To monitor a Statistics Group or Statistics Path, use the following syntax:
Note: For more information about the syntax and usage of the server_stats command, refer to the
VNX Command Line Interface Reference for File.
$ server_stats <movername> –monitor <statpath | statgroup_name> –interval
<seconds> -count <count>
where:
◆
<movername>= name of the Data Mover
◆
<statpath|statgroup_name>= a comma-separated list of statpath and statgroup
names.
◆
<seconds>= the number of seconds between samples.
◆
<count>= the number of reports that are generated.
Example:
$ server_stats server_2 -monitor cifs-std -i 3 -c 5
$ server_stats server_2 -monitor cifs-std -i 3 -c 5
server_2
CIFS
CIFS
CIFS
CIFS Avg
CIFS
Avg
CIFS
CIFS
Timestamp
Total
Read
Read
Read
Write
Share
Open
Ops/s
Ops/s
KiB/s
Size KiB
Ops/s
KiB Connections
Files
20:52:15
0
0
0
0
0
0
20:52:18
0
0
0
0
0
0
20:52:21
0
0
0
0
0
0
20:52:24
0
0
0
0
0
0
20:52:27
0
0
0
0
0
0
CIFS
CIFS
Write
Write
KiB/s
Size
0
0
0
0
0
System activity output
139
Troubleshooting
server_2
CIFS
CIFS
Avg
CIFS
CIFS
Summary
Total
Read
Share
Open
Ops/s
Ops/s
KiB Connections
Files
Minimum
0
0
0
0
Average
0
0
0
0
Maximum
0
0
0
0
CIFS
CIFS Avg
Read
Read
KiB/s
Size KiB
CIFS
CIFS
Write
Write
Ops/s
CIFS
Write
KiB/s
Size
0
-
0
0
0
-
0
0
0
-
0
0
nas_stats
nas_stats allows the user to manage Statistics Groups. There are two types of Statistics
Groups: System and User-defined groups. These groups are the same groups that
server_stats will display with –monitor, -list, and –info. nas_stats can be used to modify
existing System-defined Statistic Groups or it can be used to create new Userdefined
Statistics groups.
For more information about the syntax and usage of the nas_stats command, refer to
the VNX Command Line Interface Reference for File.
140
System Operations
Index
A
analyzing log data 122
Automatic Collection and Transfer tool
command examples 131
command options 130
configuring 126
described 125
disabling 128
problem reporting 125
running from CLI 130
user command examples 131
C
collecting event log data 122
configuring 102
connect home 102, 108
configuring 102
Control Station 66, 68, 77, 80, 88, 90, 94, 96, 98,
102
change hostname value 77
configure for IPv6 94
connect home, configuring 102
enabling daemons 80
halting locally 66
IP aliasing 98
IPv4 networking
avoid conflicts 96
restarting locally 68
set time zone 90
setting date and time 88
Data Mover
halting 69
rebooting 70
cold 70
warm 70
set time zone 91
setting date and time 88
date setting
Control Station 88
Data Mover 88
E
EMC E-Lab Navigator 134
Emergency shutdown 64
powering up after 64
VNX series 64
error messages 134
H
Halt Control Stations 65
Halt Data Movers 65
halting
Data Mover 69
dual Control Station
Locally 66
Remotely 66
single Control Station
Locally 66
Remotely 66
HTTPD daemons 80, 81
restarting 81
D
daemon
Control Station 80
HTTPD 80
I
IP aliasing
System Operations
141
Index
IP aliasing (continued)
create 98
delete 99
IP networking
change VNX management port values 100
configure IPv6 on Control Station 94
IPv6
configure IPv6 on Control Station 94
L
Linux security alerts
between software installations 79
new software installations 79
log files
automatic collection and transfer 126
problem reporting 126
M
messages, error 134
N
nas_cel 77
nas_checkup
check system status 76
IP aliasing
create 98
delete 99
nas_cs 77, 88, 90, 94
configure IPv6 on Control Station 94
setting date and time 88
setting timezone 90
nas_version 74
NTP service
configure 90
P
Powering up
VNX VG2 Gateway 36
VNX VG8 Gateway 36
VNX5100 for Block 39
VNX5300 for Block 44
VNX5300 for File 41
VNX5300 Unified 41
VNX5500 for Block 49
VNX5500 for File 46
VNX5500 Unified 46
VNX5700 for Block 55
VNX5700 for File 51
VNX5700 Unified 51
142
System Operations
Powering up (continued)
VNX7500 for Block 60
VNX7500 for File 56
VNX7500 Unified 56
powerup after emergency shutdown 64
private LAN
avoid address conflicts 96
problem reporting
automatic collection and transfer of logs 126
collecting log files 126
R
reason codes 66, 68
rebooting
Data Mover 70
Restart Control Stations 65
Restart Data Movers 65
restarting 68
dual Control Station
Locally 68
Remotely 68
single Control Station
Locally 68
Remotely 68
S
SCSI devices
discovering 84
saving 84
securing event log data 122
server_cpu
halt Data Mover 69
reboot Data Mover 70
server_date
seting Data Mover time zone 91
setting
time and date 88
server_devconfig
discovering SCSI devices 84
saving SCSI devices 84
server_snmpd
view SNMP status 95
server_version 74
date
Control Station 88
Data Mover 88
time
Control Station 88
Data Mover 88
setting time zone
Control Station using CLI 90
Data Mover using CLI 91
Index
Shutdown in emergency 64
SNMP
about 95
view 95
time setting
Control Station 88
Data Mover 88
troubleshooting 133
T
V
time service 87, 88, 90, 91
Control Station
set using CLI 90
Data Mover
set using CLI 91
setting
Control Station time and date 88
Data Mover time and date 88
verifying Control Station software version 74
verifying Data Mover software version 74
VNX database
backup 81, 82
automatic 82
manual 82
System Operations
143
Index
144
System Operations