HPL-N - Philips

HPL-N - Philips
Lighting
HPL-N
HPL-N 400W/542 E40 HG 1SL/6
Standard High Pressure Mercury lamp
Product data
General Information
Lamp Luminous Efficacy EM (Nom)
55 lm/W
Cap base
E40 [ E40]
Colour Rendering Index,horiz (Nom)
50
Burning Position
UNIVERSAL [ Any/Universal]
LLMF 2000 h Rated
88 %
Life to 5% failures (nom.)
6000 h
LLMF 4000 h Rated
86 %
Life to 20% failures (nom.)
12000 h
LLMF 6000 h Rated
84 %
Life to 50% failures (nom.)
16000 h
LLMF 8000 h Rated
82 %
LSF 2000 h Rated
99 %
LLMF 12000 h Rated
78 %
LSF 4000 h Rated
97 %
LLMF 16000 h Rated
75 %
LSF 6000 h Rated
92 %
LLMF 20000 h Rated
72 %
LSF 8000 h Rated
83 %
LSF 12000 h Rated
65 %
Operating and Electrical
LSF 16000 h Rated
45 %
Power (Rated) (Nom)
400.0 W
LSF 20000 h Rated
28 %
Lamp current (EM) (nom.)
3.25 A
Ignition supply voltage (max.)
170 V
Voltage (Max)
150 V
Light Technical
Colour Code
542 [ CCT of 4200K]
Voltage (Min)
130 V
Lamp Luminous Flux (Nom)
22000 lm
Voltage (Nom)
140 V
Colour Designation
Cool White (CW)
Lumen maintenance 2,000 hours (min.)
78 %
Controls and Dimming
Lumen maintenance 2,000 hours (nom.)
88 %
Dimmable
Lumen maintenance 5,000 hours (min.)
75 %
Lumen maintenance 5,000 hours (nom.)
85 %
Mechanical and Housing
Chromaticity coordinate X (nom.)
384
Bulb finish
Coated [ Coated glass (CO)]
Chromaticity coordinate Y (nom.)
384
Bulb material
Hard Glass
Colour Temperature, horizontal (Nom)
4200 K
Datasheet, 2017, May 8
no
data subject to change
HPL-N
Approval and Application
Order product name
HPL-N 400W/542 E40 HG 1SL/6
Energy efficiency label (EEL)
B
EAN/UPC – product
8711500180452
Mercury (Hg) content (nom.)
72 mg
Order code
928053507496
Energy Consumption kWh/1000 h
440 kWh
Numerator – quantity per pack
1
Numerator – packs per outer box
6
Material no. (12NC)
928053507496
Luminaire Design Requirements
Bulb temperature (max.)
350 °C
Net weight (piece)
0.255 kg
Cap base temperature (max.)
210 °C
ILCOS Code
QE-400/40/3-H-E40
Product Data
Full product code
871150018045299
Warnings and Safety
• For use with control gear designed for high-pressure mercury lamps
• A lamp breaking is extremely unlikely to have any impact on your health. If a lamp breaks, ventilate the room for 30 minutes and remove
the parts, preferably with gloves. Put them in a sealed plastic bag and take it to your local waste facilities for recycling. Do not use a
vacuum cleaner.
Dimensional drawing
Product
D (max)
C (max)
HPL-N 400W/542 E40 HG 1SL/6
122 mm
290 mm
HPL N 400W E40 HG
Photometric data
Datasheet, 2017, May 8
2
data subject to change
HPL-N
© 2017 Philips Lighting Holding B.V. All rights reserved. Philips Lighting reserves the right to make changes in specifications
and/or to discontinue any product at any timewithout notice or obligation and will not be liable for any consequences resulting
www.lighting.philips.com
from the use of this publication.
2017, May 8 - data subject to change
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising