electronic thermostat with alarm output
cod. 9IS42084
rel. 6/04
THE USER INTERFACE
The user has a display and four keys for
controlling status and programming of the
instrument.
KEYS AND MENUS
UP key
Scrolls through the menu items
Increases the values
DOWN key
Scrolls through the menu items
Decreases the values
FNC key
fnc
SET key
set
ESC function (exit)
Accesses the setpoint
Accesses the menus
Confirms the commands
out
f nc
set
IC901
At start-up the instrument performs a
Lamp Test; for few seconds the display and
the leds blink, in order to verify their
integrity and correct operation. The instrument has two main menus: the “Machine
Status” and “Programming” menu.
ACCESSING AND USING MENUS
Resources are arranged in a menu, which
can be accessed by pressing and quickly
releasing the “set” key (“Machine Status”
menu) or by holding down the “set” key
for more than 5 seconds (“Programming”
menu).
To access the contents of each folder, indicated by the relevant label, just press the
“set” key once.
You can now scroll through the contents
of each folder, modify it or use its functions.
If you do not use the keyboard for over 15
seconds (time-out) or if you press the
“fnc” key once, the last value shown on
the display is confirmed and you return to
the previous screen mask.
MACHINE STATUS MENU
(See Machine Status Menu Diagram)
To access the “Machine Status” menu Press
and quickly release the “set” key.
If alarms are not present, the label “SEt”
appears. By using the “UP” and “DOWN”
keys you can scroll through the other folders in the menu:
-AL: alarm folder (if present);
-Pb1: probe 1 value folder;
-SEt: Setpoint setting folder.
Set Setting
Access the “Machine Status” menu by
pressing and quickly releasing the “set”
key. The label of the “SEt” folder appears.
To display the Setpoint value press the
“set” key again.
The value appears on the display.
To change the Setpoint value, use the “UP”
and “DOWN” keys within 15 seconds.
If the parameter is LOC = y the Setpoint
cannot be changed.
Alarm on
If alarm condition exists, when accessing
The “Machine Status” menu the “AL” folder label appears (see the “Diagnostics” section).
Displaying Probes
By pressing the “set” key when the appropriate label appears, the value of the
probe associated to it is displayed.
PROGRAMMING MENU
(See Programming Menu Diagram)
To enter the “Programming” menu, press
the “set” key for more than 5 seconds.
If specified, the access PASSWORD will be
requested, (parameter “PA1”), and the
label of the first folder will follow.
To scroll through the other folders, use
the “UP” and “DOWN” keys; the folders
contain the level 1 and 2 parameters. The
level 2 parameters may be protected by a
second password (parameter “PA2”).
To enter the folder, press “set”. The label
of the first visible parameter appears. To
scroll through the other parameters, use
the “UP” and “DOWN” keys; to change the
parameter, press and release “set”, then
set the desired value using the “UP” and
“DOWN” keys, and confirm with the “set”
key to move to the next parameter.
LED
Position
Associated function
Status
out
Relay 1
ON for relay ON, flashing for delay, disabled protection
or activation
Alarm
ON for an active alarm; blink if silenced
PLEASE NOTE: It is suggested to switch-off
and switch-on again the instrument everytime it is changed the configuration of the
parameters: this prevents malfunctioning
on regulation and delay time occuring.
PASSWORD
The password “PA1”allow access to level 1
parameters. In the standard configuration
passwords are not present.
To enable them and assign them the
desired value, access the “Programming”
menu, within the folder with the “diS”
label.
If passwords are enabled, you will see PA1
at the entrance of the
“Programming” menu;
COPY CARD
The Copy Card is an accessory connected
to the TTL serial port which allows programming quickly the instrument parameters. The operation is performed as follows:
Fr-Format
This command allows copy card formatting, an operation recommended in case
of first use.
Warning: if the copy card has been programmed, using the “Fr” the data entered
are erased. This operation cannot be cancelled.
UL-Upload
This operation loads the programming
parameters from the instrument.
dL-Download
This operation downloads to the instrument the programming parameters.
The operations are performed accessing
the folder identified by the “FPr” label and
selecting, according to the case, “UL”, “dL”
or “Fr” commands; the operation is confirmed by pressing the “set” key. If the
operation is successful an “y” is displayed,
on the contrary, if it fails a “n” will be displayed.
NOTE:
• UPLOAD: instrument --> Copy Card
• DOWNLOAD: Copy Card --> instrument.
KEYBOARD LOCKING
The instrument includes a facility for disabling the keyboard, by programming the
“Loc” parameter (see folder with “Dis”
label). If the keyboard is locked, you can
still access the programming menu by
pressing the “set” key.
The Setpoint can also be viewed.
DIAGNOSTICS
INSTALLATION
The alarm condition is always signalled by
the buzzer (if present) and by the led of
the alarm icon
The alarm signal produced by a faulty
thermostat probe (probe 1) is shown as E1
on the instrument display.
Error table
DISPLAY
ERROR
E1
Thermostat probe fault
WARNING!: In 15A version buzzer is not
available.
When the sensor detects an error condition:
• the code E1 is displayed
• the regulator is activated as indicated by
the "On" and "Off" parameters if programmed for the duty cycle or:
Ont
Oft
Regulator output
0
0
>0
>0
0
>0
0
>0
OFF
OFF
ON
dc
Other signalling alarm are not shown on
the instrument display, but from the
“Machine Status” menu within the “AL”
folder.
MINIMUM AND MAXIMUM TEMPERATURE ALARMS
Regulation of the minimum and maximum
temperature alarms refers to the thermostat probe.
The temperature limits defined by the
“HAL” (maximum temperature alarm) and
“LAL” parameters (minimum temperature
alarm) are in absolute temperature value.
When an alarm status occurs, if no alarm
exclusion phases are underway (see alarm
exclusion parameters), the alarm set icon
is lit up and the buzzer, and/or the relay
configured as an alarm, is activated. The
occurrence of this alarm does not in anyway effect the control activities in
progress. This alarm status can be viewed
in the “AL” folder with AH1-AL1 labels.
DISPLAY
ALARM
AH1
High temperature alarm (referred to
the thermostat probe or probe 1)
Low temperature alarm (referred to
the thermostat probe or probe 1)
AL1
To silence alarms press any key.
If silenced it will blink.
Alarms are considered as absolute values.
IC 901 A
The instrument is designed for flush panel
mounting. Insert the unit through a
71x29 mm panel cut-out and affix with the
U-bracket supplied.
Select a location which will not be subject
to high humidity or condensation and
allow some ventilation to provide cooling
to the instrument.
ELECTRICAL
CONNECTIONS
Attention! Never work on electrical
connections when the machine is
switched on.
The instrument is equipped with screw terminal boards for connection of electrical
cables with a diameter of 2.5 mm2 (one
conductor only per terminal for power
connections). For the capacity of the terminals, see the label on the instrument.
Relay outputs are voltage free. Do not
exceed the maximum permissible current
– in case of higher loads, use a contactor
of adequate power. Make sure that the
supplied voltage matches the values specified for the instrument.
In the versions supplied on 12V, the power
supply must be provided via a safety transformer protected by a 250 mA delayed
fuse. The probes do not have any insertion
polarity and can be lengthened by using a
normal bipolar cable (note that if the
probes are lengthened, this will affect the
behaviour of the instrument in terms of
EMC electro-magnetic compatibility –
wiring must be done with great care).
We advise you to keep the probe and supply cables well away from the power
cables.
CONDITIONS OF USE
PERMITTED USE
For safety reasons the instrument must be
installed and used according to the
instruction provided and in particular,
under normal conditions, parts bearing
dangerous voltage levels must not be
accessible.
The device must be adequately protected
from water and dust as per the application
and must also only be accessible via the
use of tools (with the exception of the
frontlet).
The device is ideally suited for use on
household appliances and/or similar refrigeration equipment and has been tested
with regard to the aspects concerning
European reference standards on safety. It
is classified as follows:
• according to its manufacture: as an automatic electronic control device to be
incorporated by independent mounting;
• according to its automatic operating features: as a 1 B-type operated control type;
• as a Class A device in relation to the category and structure of the software
UNPERMITTED USE
Any other use other than that permitted is
de facto prohibited. It should be noted
that the relay contacts provided are of a
practical type and therefore subject to
fault. Any protection devices required by
product standards or dictated by common
sense due to obvious safety reasons should
be applied externally.
TECHNICAL DATA
Frontal panel protection: IP65.
Casing: plastic body in resin type
PC+ABS UL94 V-0, inspection window in
polycarbonate, buttons in thermoplastic
resin.
Dimensions: frontal panel 74x32 mm,
depth 60 mm.
Installation: on panel, with drilling template 71x29 mm (+0.2/–0.1 mm).
Use temperature: –5…55 °C.
Storage temperature.: –30…85 °C.
Use environment humidity: 10…90 % RH
(not condensing).
Storage environment humidity: 10…90% RH
(not condensing).
Viewing range: -50…99 °C (NTC), –55…99
°C (PTC) on 3 digit 1/2 + mark display.
Analog inputs: one PTC or NTC input
(selectable through parameter).
Serial: TTL for connection to Copy Card.
Digital outputs:
(A) one relay output, SPDT 8(3)A 250Va
relay,
(B) one relay output, SPST 8(3)A 250Va
relay or one relay output, SPST 15A (1hp)
250Va relay (for relay capacities check on
the instrument label)
Measuring range: from –55 to 99 °C.
Accuracy: 0.5% better than end scale + 1
digit.
Resolution: 1°C.
Consumption
• model 230V: 3 VA max.
• model 12V: 1,5 VA max.
Power supply: 12 Va/c ±10% or 230Va
±10% 50/60 Hz.
Warning: check the power supply specified
on the instrument label; for relay and
power supply capacities, contact the Sales
Office).
PLEASE NOTE: The technical data
included in this document, related to
measurement (range, accuracy, resolution, etc.) refer to the instrument
itself, and not to its equipment such as,
for example, sensors.
This means, for example, that sensor(s)
error(s) shall be added to the instrument’s one.
2/5
Tab. 1
Parameter table
PARAMETER DESCRIPTION
diF
HSE
LSE
HC
Ont
OFt
dOn
dOF
dbi
OdO (!)
AFd
HAL
LAL
PAO
tAO
LOC
PA1
CA1
dro
H00 (*) (!)
rEL
tAb
UL
dL
Fr
REGULATOR (folder with “CP”)
Relay regulator tripping differential. The regulator stops on reaching the Setpoint value (as indicated by the adjustment probe), and
restarts at temperature value equal to the Setpoint plus the value
of the differential.
Note: the value 0 cannot be assumed.
Maximum possible setpoint value.
Minimum possible setpoint value.
Heat/Cool Mode. If set to H the generic regulator actuates for hot
operation. If set to C the generic regulator actuates for cold operation
REGULATOR PROTECTIVE DEVICES (folder with “CP” label)
Regulator activation time in the event of faulty probe. If set to “1”
with Oft at “0”, the regulator is always on, while for Oft >0,
it functions always in duty cycle mode.
Regulator in disabled state time in the event of a faulty probe. If
set to “1” with Ont at “0”, the regulator is always off, while at Ont
>0, it functions always in duty cycle mode.
Delay time in activating the regulator relay after switch-on of
instrument.
Delay after switch off. The indicated time must elapse between
switch-off of the regulator relay and the successive switch-on.
Delay between switch-ons. The indicated time must elapse between
two successive switch-ons of the regulator.
delay time in activating the outputs after switch-on of the instrument or after a power failure.
ALARMS (folder with “AL” label)
Alarm Fan differential. Alarm differential.
Higher ALarm. Maximum temperature alarm. Temperature value (in
absolute value), which if exceeded in an upward direction triggers
the activation of the alarm signal.
Lower ALarm. Minimum temperature alarm. Temperature value (in
absolute value), which if exceeded in a downward direction, triggers the activation of the alarm signal.
Power-on Alarm Override. Alarm exclusion time after instrument
switch on, after a power failure.
temperature Alarm Override. Temperature alarm signal delay dime.
DISPLAY (folder with label “diS”)
Keyboard locking (set and keys). However, you can enter parameter
programming, modify them and change the status of this parameter to unlock the keyboard.
y = yes; n = no.
Password 1. When enabled (value other than 0) it constitutes the
access key for level 1 parameters.
Calibration 1. Positive or negative temperature value added to the
value read on the adjustment room probe (probe 1) before being
displayed and used for adjustment.
Selection of °C or °F to view the temperature read by the probe.
0 = °C, 1 = °F.
CONFIGURATION (folder with label “CnF”)
Probe type selection, PTC or NTC. 0 = PTC; 1 = NTC.
Device version. Read only parameter.
Reserved. Read only parameter.
COPY CARD (folder with label “Fpr”)
UpLoad: transferring parameters from instrument to Copy Card.
downLoad: transferring parameters from Copy Card to instrument.
Format. Erasing all data in the copy card.
PLEASE NOTE: using “Fr” parameter (copy card formatting)
the data within the copy card will be lost permenently. The
operation cannot be cancelled.
LIEVEL***
U.M.
2
1
°C/°F
LSE..99
-55...HSE
H/C
99
-55
C
1
1
1
°C/°F
°C/°F
flag
0...250
0
1
min
0...250
1
1
min
0...250
0
1
sec
0...250
0
1
min
0...250
0
1
min
0...250
0
1
min
1…50
LAL…150
2
50
1
1
°C/°F
°C/°F
-50.…HAL
-50
1
°C/°F
0…10
0
1
hours
0…999
0
1
min
n/y
n
1
flag
0...250
0
1
num.
-12...12
0
1
°C/°F
0/1
1
1
RANGE
DEFAULT*
1...30
VALUE**
flag
0/1
/
/
0/1*
/
/
1
1
1
flag
/
/
/
/
/
/
/
/
1
1
1
/
/
/
* DEFAULT column: for H00 parameter default is depending on model
* NOTE 1: Switch off and switch on again the instrument after changing the input type NTC/PTC (par. H00)
** VALUE column: to be filled manually, with customized settings (if different from the default value).
*** LEVEL column: indicates the level of visibility of parameters accessible by PASSWORD (see the related paragraph)
(!) WARNING!
• If one or more of these parameters highlighted with (!) are modified, teh controlller must be switched off and switched on again to ensure correct operation.
LIABILITY AND RESIDUAL RISKS
DISCLAIMER
Eliwell & Controlli s.r.l. shall not be liable for any damages deriving from:
- installation/use other than that prescribed and, in particular,
that which does not comply with safety standards anticipated by
regulations and/or those given herein;
- use on boards which do not guarantee adequate protection
against electric shock, water or dust under the conditions of
assembly applied;
- use on boards which allow access to dangerous parts without
the use of tools;
- tampering with and/or alteration of the products;
This manual and its contents remain the sole property of Eliwell
& Controlli s.r.l., and shall not be reproduced or distributed without authorization. Although great care has been exercised in the
preparation of this document, Eliwell & Controlli s.r.l., its employees or its vendors, cannot accept any liability whatsoever connected with its use. Eliwell & Controlli s.r.l. reserves the right to
make any changes or improvements without prior notice.
IC 901 A
3/5
MENU DIAGRAMS
press and release
(single press)
set
AL
set
alarms
if alarm(s)
present
show alarms
SEt
set
SEt value
change SEt
value
Pb1
set
Pb1 value
Machine Status Menu Diagram
Programming Menu Diagram
press for 5 sec
set
PA1≠0
set
set PA1 value
PARAMETERS
folders level 1
CP
AL
diS
CnF
FPr
IC 901 A
CP
set
level 1 par
AL
set
level 1 par
diS
set
level 1 par
CnF
set
level 1 par
Fpr
set
level 1 par
scroll
parameters
change
par value
level 1
4/5
Wiring diagram
WIRING
1-2
1-3
4-5
6-7
8 - 10
A
A
IC 901 A - 12 V
N.O. regulator 1 relay output out1
N.C. regulator 1 relay output out1
N.O. regulator 2 relay output (alarm) out2
Power supply 1,5 VA max. (12V version)
Power supply 3 VA max. (230V version)
Probe 1 input (thermostat)
TTL input for Copy Card
out1
out2
1 2 3 4 5
6 7 8 9 10
PLEASE NOTE:
• User Default Settings
• for relay capacities check on the instrument label
A
IC 901 A - 230 V
out1
out2
1 2 3 4 5 6 7
WIRING
1-2
1-3
4-5
6-7
8 - 10
A
N.O. regulator 1 relay output (alarm) out1
N.C. regulator 1 relay output (alarm) out1
N.O. regulator 2 relay output out2
Power supply 1,5 VA max. (12V version)
Power supply 3 VA max. (230V version)
Probe 1 input (thermostat)
TTL input for Copy Card
8 9 10
A
IC 901 A - 12 V
out1
out2
1 2 3 4 5
6 7 8 10 9
PLEASE NOTE:
• User Default Settings
• for relay capacities check on the instrument label
WARNING:
For 15A version buzzer is not available
A
IC 901 A - 230 V
out1
out2
1 2 3 4 5 6 7
8 10 9
Eliwell & Controlli s.r.l.
Via dell'Industria, 15 Zona Industriale Paludi
32010 Pieve d'Alpago (BL) ITALY
Telephone +39 0437 986111
Facsimile +39 0437 989066
Internet http://www.eliwell.it
Technical Customer Support:
Email: techsuppeliwell@invensys.com
Telephone +39 0437 986300
Climate Controls Europe
An Invensys Company
6/2004 eng
cod. 9IS42084
IC 901 A
5/5
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising