INTRODUCTION
The underfloor heating system is compromised of three components:
1. The heat source (typically a boiler)
2. Distribution of the water into the floor circuit using a manifold
3. The control of these circuits using thermostats.
The heat source produces warm water that is turn circulated though the primary
circuit to the manifold. Conventional boilers produce water at a temperature much
greater than that needed by an underfloor heating system and as a consequence
the manifold must use a water mixing valve to reduce the water to a useful
temperature, typically 40°C to 55°C. The mixed water is then circulated through
the manifold by the secondary circulator and distributed into the underfloor
heating circuits.
As each room becomes cold so the corresponding thermostats will switch on. Each
thermostat is connected via a wiring centre to a zone valve or actuator.
As a thermostat “calls for heat” so two volt-free terminals on the wiring centre
close.
One completing the circuit to fire the boiler and one enabling the live supply to the
circulator. The actuator for the appropriate circuit will open allowing warm water to
flow into that circuit warming up the floor. When the room is warmed up to
temperature and the set point is reached, say 20°C, the thermostat will switch off,
closing the actuator. When all the thermostats have switched off or stopped
“calling for heat” the wiring centre switches off the secondary circulator on the
manifold and stops firing the boiler.
Sensor Network Wiring Detail
The Room Sensor network consists of 4 conductors in a screened cable. There are two twisted pairs of
low voltage wires; power conductors; black -ve and red +ve and data yellow b- and white b+. The
network is terminated by connecting a link wire between e and b-, it will not work without this. A link is
also inserted between C2 (i - f) which is the other end of the network. Links are not fitted to the
intermediate sensors.
Connect the screen at one end of the cable to terminal C2 -ve to drain away induced noise.
First Sensor on BUS
Intermediate Sensors
Room Sensor
Room Sensor
C2
Last Sensor on BUS
C2
C1
C1
e b+ b- + -
e b+ b- + -
Repeat wiring detail
Control Hub Network Wiring Detail
The Control Hub network obeys the same rule, the link is fitted to the Outdoor Sensor and to the
last Wiring Centre. The control Hub is always located between the Wiring Centres or Wiring Centre
and the Outdoor Sensor.
The screen should be connected to C3 -ve at one end only to drain away any induced noise. Use a
cable stripper to remove the insulation on the conductors to avoid nicks in the wire which will lead to
breaks and system failure.
Outdoor
Sensor
Control Hub
C4
C3
e b+ b- + C3
C4
- + b- b+
Link wire at
End of BUS
Omnie Network Controls Wiring Diagram Single Manifold 230V
1)
2)
3)
4)
5)
6)
Up to 8 Room Sensors can be connected to each Wiring Centre via the network BUS cable. Terminate the last Room Sensor with a link between C2: e & b- and the Wiring Centre at C2: I & f.
Wired and wireless Room Sensors can be connected on the same Wiring Centre, make the Access Point the first sensor on the network.
Control Hub is connected between wiring centres or outdoor sensor - not at the end of the Network.
Add a link in the Outdoor Sensor between C4: b- & e
BUS cables MUST be wired in a daisy chain, do not wire radially.
Connect the screen wire to the negative terminal (black wire) at one end only of each section.
First Sensor on BUS
Room Sensor
Room Sensor
C2
Outdoor Temperature
Sensor
Last Sensor on BUS
Intermediate Sensors
C2
C1
Control Hub
C1
e b+ b- + -
e b+ b- + -
Link Wire at the end of the BUS
C4
C3
e b+ b- + -
Connect the screen wire
to the negative terminal on C3
C3
C4
Link wire at
End of BUS
- + b- b+
BUS cable
230V 6A isolated supply
Link Wire
Link Wire
U1
N-N E L-L
AC 230V
+ -
b+b- — i f
C2
C1
Omnie Wiring Centre
A0
b+b- — i f
C3
C4
m r
D1
A1
LN
m r
D2
a b
AN
DG
A2 A3 A4
A5
A6
LN LN LN LN LN
a b
U2
C6
C5
Volt Free Contacts
Powered Contacts
Underfloor Actuators
230V 6A
LEN
+ -
DHW
A7
A8
A9
LN LN LN
Mixer
Circ
A10
C L
A11
a b-
Vent
A12
a b-
Boiler
Change
Over
A13
a b-
A14
a b-
MVHR Boost - Volt free
contacts
Up to 5 actuators per
channel (max) using
channel cap terminals.
OT
T
DHW
motorised
valve ignore if
using a combi
boiler or heat
pump
Boiler
Circulator Supply 230V
Cylinder Stat
Omnie Underfloor Heating Manifold
Notes:
1)
Please refer to the boiler manufacturers instruction for switching
2)
Refer to the Installation manual for network cable specification.
Omnie Network Controls Wiring Diagram Single Manifold V3.2
If connecting to the thermostat terminal
Use A13 volt free.
If Switched Live is needed connect A13: a to
to A0: L and use A0: N if required.
Connect the boiler input to the switch
contacts in the DHW diverter valve
C3
Manifold
D
6 Ports
L.N.E
L.N.E
L.N.E
Up to 5 actuators per
channel (max) using
channel cap terminals.
L.N.E
230V
Up to 5 actuators
per
L.N.E
230V
C2
e b+ b-
C1
- +
Room
Sensor
Room Sensors
Link
Link at end of Bus
Link
C2
e b+ b-
T
Cylinder Stat
OT
T
C3
- +
C4
b- b+
Control Hub
DHW Cylinder
stat and
diverter valve
Volt Free
Wiring Centre
Cylinder Stat
OT
Volt Free Terminals
Wiring Centre
Link at end of Bus
Link at end of Bus
Link
C1
- +
Room
Sensor
Notes:
1. Please refer to boiler manufacturer’s instructions for switching
2. Room Sensors and Wiring Centres are connected by screened BUS cable. Refer
to the installation manual for specification.
230V 6A supply
4 Zones
L.N.E
230V 6A supply
8 Zones
Manifold
A
8 Ports
e b+ b- + -
C4
Outdoor Temperature
Sensor
Circulator
Circulator Supply 230V
L.N.E
230V
C2
e b+ b-
Link at end of Bus
C2
e b+ b-
Link
Link
C1
- +
Room
Sensor
Link at end of Bus
Volt Free Terminals
Wiring Centre
Volt Free Terminals
Wiring Centre
Omnie Controls Layout for 4 Manifolds Manual Mixers
C1
- +
Room
Sensor
Up to 5 actuators per
channel (max) using
channel cap terminals.
L.N.E
230V
L.N.E
230V 6A supply L.N.E
Up to 5 actuators per
channel (max) using
channel cap terminals.
230V 6A supply
Manifold
C
6 Ports
3 Zones
Manifold
B
6 Ports
6 Zones
Circulator Supply 230V
Circulator Supply 230V
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising