SS --- PG95XAT --- 03
PG95XAT
CONDENSING GAS FURNACE
Product Data
STANDARD FEATURES
S Heating efficiency of 95.5% AFUE.
S All sizes meet ENERGY STARR Version 4.0 criteria for gas
furnaces: 95+ AFUE; AMACF electrical rating; 2% or less
cabinet airflow leakage.
S Two heating stages.
S Efficient ECM blower motor.
S 4--way multipoise furnace.
S Humidity control when paired with a compatible condensing
unit and using a humidity sensing thermostat.
S Adjustable constant fan speed from a compatible thermostat.
S LED diagnostics and self test feature.
S Stores fault codes during power outages.
S Adjustable heating air temperature rise.
S Approved for Twinning applications (42060 through 66120
sizes, only).
S Dehumidification terminals on control board
S Hot surface ignition.
S Dual fuel compatible.
S Two--speed inducer motor.
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1--in. water column with all
present air inlets, air outlets, and condensate drain port(s) sealed.
LIMITED WARRANTY*
A11300
Utilizing the extensive resources available to PayneR, a new
standard of excellence has been achieved with the model
PG95XAT. The model is a unique 4--way multipoise condensing
furnace with features like no other product in its class including
two heating stages and an efficient ECM Blower Motor. The
PG95XAT builds on the many Payne successes in the furnace
industry and establishes a new standard for all high--efficiency gas
furnaces.
S 20--year limited warranty on heat exchangers.
S 10 year parts limited warranty to the original purchaser upon
timely registration.
S Limited warranty period is five years for parts and twenty years
for the heat exchanger if not registered within 90 days of
installation.{
* For owner occupied, residential applications.
{Jurisdictions where warranty benefits cannot be conditioned on registration will receive registered limited warranty benefits.
Always Ask For
CERTIFIED
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
1
SAP ORDERING NO.
PG95XAT30040A
PG95XAT42060B
PG95XAT48080B
PG95XAT60080C
PG95XAT60100C
PG95XAT66120D
CASING
DIMENSIONS
(IN.)
H
D
35
35
35
35
35
35
30
30
30
30
30
30
W
RATED HEATING
OUTPUT† (BTUH)
High
14.2 39,000
17.5 58,000
17.5 78,000
21.0 78,000
21.0 97,000
24.5 117,000
HEATING AIRFLOW
Low
AFUE
CFM‡
(Low
Heating)
CFM
(High
Heating)
High
Heating
ESP
25,000
38,000
50,000
51,000
63,000
76,000
95.5%
95.5%
95.5%
95.5%
95.5%
95.5%
590
785
1095
1055
1325
1610
695
1000
1360
1360
1700
2125
0.10
0.12
0.15
0.15
0.20
0.20
COOLING
CFM
@ 0.5 ESP
MOTOR
HP-SPEED
APPROX.
SHIP
WT (LB)
385-925
530-1505
920-1610
795-2015
1105-2110
1385-2055
1/2 - 5
3/4 - 5
3/4 - 5
1-5
1-5
1-5
125
146
156
161
171
195
† Capacity in accordance with DOE test procedures. See rating plate.
‡ Heating CFM at factory default blower motor heating tap settings.
ESP --- External Static Pressure
PG95XAT
FEATURES AND BENEFITS
Advanced Heat Staging — This furnace promotes homeowner
comfort through two stages of heating by offering a patented
algorithm that continually monitors and adjusts furnace operation.
By looking at both current and past conditions to determine the
most effective stage of heating and the amount of time to run each
stage, every cycle the furnace confidently meets the homeowner
comfort demands each and every time.
Advanced Dehumidification — When paired with a compatible
thermostat, this dehumidification feature overrides the cooling
blower off-delay when there is a call for dehumidification. By
deactivating the blower off-delay, this feature prevents condensate
that remains on the coil after a dehumidification cycle from
re-humidifying throughout the home. This results in reduced
humidity and a more comfortable indoor environment for the
homeowner.
Unlike competitive systems, this feature only overrides the cooling
blower off delay when humidity control is needed. Once humidity
is back in control, the energy-saving cooling blower off-delay is
re-enabled.
Adjustable Fan Speeds — Constant fan setting on a standard
furnace system can sometimes actually reduce homeowner comfort
by providing too much or too little air! This feature improves
comfort all year long by allowing the homeowner to select the
continuous fan speed of their choice using a compatible thermostat.
HYBRID HEATR Dual Fuel System Compatible — This
system can provide more control over your monthly energy bills
by automatically selecting the most economical method of heating.
With HYBRID HEAT components, our system automatically
switches between the gas furnace and the electric heat pump as
outside temperatures change to maintain greater efficiency and
comfort than with any traditional single-source heating system.
The heat pump also delivers high-efficiency cooling in the summer.
Robust Igniter — Payne’s unique SiN igniter is not only
physically robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage
regulators as do other brands. This unique feature further enhances
the gas furnace reliability and continues Payne’s tradition of
technology leadership and innovation in providing a reliable and
durable product.
ECM Blower Motor — Our ECM, or electronically commutated
motor, can provide an efficiency enhancement for select Payne air
conditioner or heat pump systems. It uses less electrical power than
its PSC counterpart and also has a wider range of speeds
Reliable Heat Exchanger Design — The aluminized steel,
clamshell primary heat exchanger was reengineered to achieve
greater efficiency out of a smaller size. The first two passes of the
heat exchanger are based on the current 80% product, a design
with more than ten years of field-proven performance and success.
These innovations, paired with the continuation of a crimped,
no-weld seam create an efficient, robust design for this essential
component.
The condensing heat exchanger, a stainless steel fin and tube
design, is positioned in the furnace to extract additional heat.
Stainless steel coupling box componentry between heat exchangers
has exceptional corrosion resistance in both natural gas and
propane applications.
4-Way Multipoise Design — One model for all applications –
there is no need to stock special downflow or horizontal models
when one unit will do it all. The new heat exchanger design allows
these units to achieve the certified AFUE in all positions.
Direct or Single-pipe Venting, or Optional Ventilated
Combustion Air — This furnace can be installed as a 2-pipe
(Direct Vent) furnace, in an optional ventilated combustion air
application, or in single-pipe, non-direct vent applications. This
provides added flexibility to meet diverse installation needs.
Sealed Combustion System—This furnace brings in combustion
air from outside the furnace, which results in especially quiet
operation. By sealing the entire combustion vestibule, the entire
furnace can be made quieter, not just the burners.
Insulated Casing — Foil-faced insulation in heat exchanger
section of the casing minimizes heat loss. The acoustical insulation
in the blower compartment reduces air and motor noise for quiet
operation.
Monoport Burners — The burners are specially designed and
finely tuned for smooth, quiet combustion and economical
operation.
Bottom Closure — Factory--installed for side return; easily
removable for bottom return. The multi-use bottom closure can
also serve for roll-out protection in horizontal applications, and act
as the bottom closure for the optional return air base accessory.
Blower Access Panel Switch — Automatically shuts off 115-v
power to furnace whenever blower access panel is opened.
Quality Registration — Our furnaces are engineered and
manufactured under an ISO 9001 registered quality system.
Certifications — This furnace is CSA (AGA and CGA) design
certified for use with natural and propane gases. The furnace is
factory--shipped for use with natural gas. A CSA listed gas
conversion kit is required to convert furnace for use with propane
gas. The efficiency is GAMA efficiency rating certified. This
furnace meets California Air Quality Management District
emission requirements.
2
Input
Output
Efficiency
(BTUH)
(BTUH)
(BTUH)
(BTUH)
High Heat
Certified Temperature Rise Range ºF (ºC)
Low Heat
30040
40,000
26,000
39,000
25,000
95.5
40 - 70
(22 - 39)
30 - 60
(17 - 33)
42060
48080
60080
60100
60,000
80,000
80,000 100,000
39,000
52,000
52,000
65,000
58,000
78,000
78,000
97,000
38,000
50,000
51,000
63,000
95.5
95.5
95.5
95.5
40 - 70 40 - 70 40 - 70 40 - 70
(22 - 39) (22 - 39) (22 - 39) (22 - 39)
30 - 60 30 - 60 30 - 60 30 - 60
(17 - 33) (17 - 33) (17 - 33) (17 - 33)
66120
120,000
78,000
117,000
76,000
95.5
40 - 70
(22 - 39)
30 - 60
(17 - 33)
30040
0.10
0.5
695
590
925
2
2.5
42060
48080
60080
60100
0.12
0.15
0.15
0.20
0.5
0.5
0.5
0.5
1000
1360
1360
1700
785
1095
1055
1325
1505
1610
2015
2110
3.5
4
5
5
4
4.5
5.5
6
Electronically Commutated Motor (ECM)
3/4
3/4
1
1
8.4
8.4
10.9
10.9
600 - 1200
5
11 x 8
11 x 8
11 x 10 11 x 10
Field Supplied
66120
0.20
0.5
2125
1610
2055
5
6
Airflow Capacity and Blower Data
Certified External Static Pressure (in. w.c.)
Airflow Delivery @ Rated ESP (CFM)
Cooling Capacity (tons) @ 400, 350 CFM/ton
Direct-Drive Motor Type
Direct-Drive Motor HP
Motor Full Load Amps
RPM Range
Speed Selections
Blower Wheel Dia x Width
Air Filtration System
Filter Used for Certified Watt Data
Electrical Data
Input Voltage
Operating Voltage Range
Maximum Input Amps
Unit Ampacity
Minimum Wire Size
Maximum Wire Length @ Minimum Wire Size
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Transformer Capacity (24vac output)
External Control Power Available
Heating
Cooling
High Heat
Low Heat
Cooling
400 CFM/ton
350 CFM/ton
1/2
6.8
in.
11 x 7
KGAWF1606UFR
Volts-Hertz-Phase
Min-Max
Amps
Amps
AWG
Feet
(M)
Amps
KGAWF1306UFR
30040
42060
7.5
10.3
14
36
(11.0)
9.2
12.4
14
29
(8.8)
15
15
KGAWF1406UFR
48080
60080
115-60-1
104-127
9.2
11.7
12.4
15.5
14
12
29
37
(8.8)
(13.3)
15
20
1
10.9
11 x 11
KGAWF1506UFR
60100
66120
11.8
15.6
12
36
(10.7)
11.8
15.6
12
36
(11.0)
20
20
40 VA
24.3 VA
34.6 VA
Heating
Cooling
Controls
Gas Connection Size
Burners (Monoport)
Gas Valve (Redundant)
30040
2
Manufacturer
Minimum Inlet Gas pressure (in. wc)
Maximum Inlet Gas pressure (in. wc)
Gas Conversion Kit - Natural to Propane
Gas Conversion Kit - Propane to Natural
Manufactured (Mobile) Home Kit
Ignition Device
Limit Control
Heating Blower Control (Heating Off-Delay)
Cooling Blower Control (Time Delay Relay)
Communication System
Thermostat Connections
Accessory Connections
165
3
42060
48080
60080
60100
66120
1/2" - NPT
3
4
4
5
6
White Rogers
4.5
13.6
KGANP51012SP
KGAPN43012SP
not approved for MH use
Silicon Nitride
180
170
200
180
160
Adjustable: 90, 120, 150, 180 seconds
90 seconds
none
Com 24V, R, W/W1, G, Y/Y2, DHUM, Y1, W2
EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
PG95XAT
SPECIFICATIONS
Heating Capacity and Efficiency
High Heat
Low Heat
High Heat
Low Heat
AFUE % (ICS)
MODEL NUMBER NOMENCLATURE
1
Brand
P
2
Product
G
3-4
Effy.
95
5
Voltage/Motor
X
6
Major Series
A
8-9
10 - 12
Cooling Cap. Heating Cap.
30
040
7
Htg. Stages
T
13
Width/Variation
A
14
Minor Series
A
A - 14.2” Std.
B - 17.5” Std.
C - 21.0” Std.
D - 24.5” Std.
Minor Series
15 - 16
Variations
AA
Brand
Product
040=40,000 BTU
060=60,000 BTU
080=80,000 BTU
100=100,000 BTU
120=120,000 BTU
Efficiency
Variations
S - Std./PSC
X - High Eff.
Major Series
T - Two-stage
S - Single-stage
Cooling Cap.
Not all familes have these models.
PG95XAT
A11166
FURNACE COMPONENTS
GAS BURNER
HOT SURFACE
IGNITER
MANUAL RESET
ROLLOUT SWITCH
FLAME
SENSOR
MANUAL RESET
ROLLOUT SWITCH
GAS VALVE
MAIN LIMIT SWITCH
(BEHIND GAS VALVE)
OPERATING INSTRUCTIONS
NOT SHOWN (LOCATED ON
MAIN FURNACE DOOR, SEE
OPERATING INSTRUCTIONS
INSIDE DOOR FIGURE).
INDUCER MOTOR
ASSEMBLY
ELECTRICAL JUNCTION
BOX (IF REQUIRED,
LOCATION MAY VARY)
BLOWER DOOR
SAFETY SWITCH
BLOWER AND
MOTOR
FURNACE
CONTROL
BOARD
CAPACITOR/
POWER CHOKE
(IF USED)
RATING PLATE NOT SHOWN
(LOCATED ON BLOWER DOOR)
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.
A11485
4
Venting Accessories
Vent Kit - Through the Cabinet
2-in.
3-in.
2-in.
3-in.
Vent Terminal - Concentric
Vent Terminal Bracket
Condensate Drainage Accessories
Freeze Protect Kit - Heat Patch for Drain Trap
Freeze Protect Kit - Heat Tape
CPVC to PVC Drain Adapter - 1/2-in. CPVC to 3/4-in. PVC
Horizontal Trap Grommet for Direct Vent Applications
Condensate Neutralizer Kit
Ductwork Adapter Accessories
Furnace Base Kit for Combustible Floors
Coil Adapters Kits - Painted
Return Air Base (Upflow applications) - Painted
IAQ Device Duct Adapters (side return) - Painted
No Offset
Single Offsett
Double Offset
14.2-in. wide
17.5-in. wide
21-in. wide
24.5-in. wide
20-in IAQ to 16-in side return
24-in IAQ to 16-in side return
Gas Conversion Accessories
Gas Cnv Kit - Nat to LP; Two-stage
Gas Cnv Kit - LP to Nat; Two-stage
#42 Natural Gas
#43 Natural Gas
#44 Natural Gas
#45 Natural Gas
#46 Natural Gas
#47 Natural Gas
#48 Natural Gas
#54 LP
#55 LP
#56 LP
1.25 mm LP
1.30 mm LP
Gas Orifice Kit
Control Accessories
Twinning Kit
IAQ Accessories
Filter Rack - Side Return for 1" Filters
Filter Rack - Bottom Return for 1" Filters
Filter Pack (6 pack) - Washable
Filter Cabinet - Side or Bottom Return for 4" Filters
EZ-Flex Filter
EZ-Flex Filter with End Caps
Cartridge Media Filter
16 X 25
14.2-in. wide
17.5-in. wide
21-in. wide
24.5-in. wide
16 x 25 x 1
24 x 25 x 1
16-in.
20-in.
24-in.
16-in.
20-in.
24-in.
16-in.
20-in.
24-in.
16-in.
20-in.
24.in.
Part Number
Used With
Notes
KGADC0101BVC
KGAVT0701CVT
KGAVT0801CVT
KGAVT0101BRA
KGAVT0201BRA
All
See Venting Tables
See Venting Tables
See Venting Tables
See Venting Tables
1
1
1
1, 2
1, 2
Part Number
Used With
Notes
KGAHT0201CFP
KGAHT0101CFP
KGAAD0110PVC
KGACK0101HCK
P908-0001
All
All
All
All DV Horizontal
All
7
6
Part Number
Used With
Notes
KGASB0201ALL
KGADA0101ALL
KGADA0201ALL
KGADA0301ALL
KGARP0301B14
KGARP0301B17
KGARP0301B21
KGARP0301B24
KGAAD0101MEC
KGAAD0201MEC
All
All
All
All
14.2" Wide Furnaces
17.5" Wide Furnaces
21" Wide Furnaces
24.5" Wide Furnaces
20"x25" IAQ Devices
24"x25" IAQ Devices
7
7
7
7
7
7
Part Number
Used With
Notes
KGANP51012SP
KGAPN43012SP
KGAHA0150N42
KGAHA0250N43
KGAHA0350N44
KGAHA0450N45
KGAHA0550N46
KGAHA1550N47
KGAHA1650N48
KGAHA0650P54
KGAHA0750P55
KGAHA0850P56
KGAHA5750125
KGAHA5750130
All
All
All
All
All
All
All
All
All
All
All
All
All
All
4, 6
4, 6
4
4
4
4
4
4, 6
4
4, 6
4, 6
4, 6
Part Number
Used With
Notes
KGATW0701HSI
42060, 48080, 60080,
48100, 60100, 66120
-
Part Number
Used With
Notes
KGAFR0801SRE
KGBFR0401B14
KGBFR0501B17
KGBFR0601B21
KGAFR0701B24
KGAWF1306UFR
KGAWF1506UFR
FILCABXL0016
FILCABXL0020
FILCABXL0024
EXPXXFIL0016
EXPXXFIL0020
EXPXXFIL0024
EXPXXUNV0016
EXPXXUNV0020
EXPXXUNV0024
FILXXCAR0016
FILXXCAR0020
FILXXCAR0024
All
14.2" Wide Furnaces
17.5" Wide Furnaces
21" Wide Furnaces
24.5" Wide Furnaces
All
All
All
All
All
EZXCAB--1016
EZXCAB--1020
EZXCAB--1024
EZXCAB--1016
EZXCAB--1020
EZXCAB--1024
FILCABXL1016
FILCABXL1020
FILCABXL2024
5
3, 5
3, 5
3, 5
3, 5
5
5
3, 5
3, 5
3, 5
3, 5
3, 5
3, 5
3, 5
3, 5
3, 5
3, 5
3, 5
3, 5
Notes:
1. CSA requires that a termination kit be used. See latest PD for pipe and kit size selection. The qualified installer or agency must use only
factory-authorized kits when modifying these furnaces.
2. Not for use with Concentric Vent Termination Kits.
3. Last 2 digits of Part Number indicate filter size.
4. Last 2 digits of Part Number indicate orifice size.
5. Choose IAQ/filter assembly appropriate for the designed system airflow and static pressure. Use optional IAQ Device Duct Adapters as required.
6. Available from Replacement Components group.
7. Kit coming soon. Expected availability 2Q2012.
5
PG95XAT
ACCESSORIES
PG95XAT
AIR DELIVERY - CFM (BOTTOM RETURN WITH FILTER)
UNIT
SIZE
RETURN-AIR
CONNECTION
030040
SIDE/BOTTOM
042060
SIDE/BOTTOM
048080
SIDE/BOTTOM
060080
BOTTOM or
TWO-SIDES 4, 5
060100
BOTTOM or
TWO-SIDES 4, 5
066120
BOTTOM or
TWO-SIDES 4, 5
SPEED
TAPS 2, 3
Gray
Yellow
Blue
Orange
Red
Gray
Yellow
Blue
Orange
Red
Gray
Yellow
Blue
Orange
Red
Gray
Yellow
Blue
Orange
Red
Gray
Yellow
Blue
Orange
Red
Gray
Yellow
Blue
Orange 3
Red 3
0.1
1120
880
695
640
570
1720
1325
1010
1160
785
1810
1535
1380
1180
1100
2290
1810
1385
1560
1055
2340
1950
1750
1570
1350
2275
1875
2170
1475
1625
0.2
1080
845
665
595
525
1670
1285
970
1115
715
1770
1500
1340
1130
1045
2225
1760
1340
1520
985
2295
1900
1700
1520
1280
2230
1820
2125
1420
1565
EXTERNAL STATIC PRESSURE (IN.W.C.)
0.3
0.4
0.5
0.6
0.7
0.8
1030
980
925
875
820
760
810
780
740
710
680
640
620
575
535
495
455
420
540
495
460
420
370
310
475
425
385
330
255
220
1620
1565
1505
1440
1375
1295
1255
1220
1185
1145
1115
1075
925
875
835
785
745
690
1080
1045
1000
960
920
875
655
595
530
490
435
385
1720
1665
1610
1540
1475
1400
1475
1435
1405
1370
1340
1310
1305
1270
1240
1200
1165
1130
1095
1060
1015
975
935
895
1010
970
920
885
845
790
2155
2090
2015
1930
1845
1750
1725
1685
1640
1600
1555
1520
1285
1240
1200
1140
1090
1050
1475
1430
1385
1335
1295
1240
910
860
795
750
680
615
2250
2195
2110
2030
1935
1835
1855
1800
1755
1705
1655
1605
1650
1605
1555
1500
1455
1395
1460
1410
1350
1300
1240
1195
1225
1155
1105
1045
1000
950
2185
2130
2055
1950
1825
1710
1770
1720
1660
1600
1550
1505
2075
2025
1975
1900
1790
1695
1350
1280
1215
1165
1105
1050
1505
1445
1385
1325
1275
1225
0.9
690
615
370
260
-6
1220
1040
660
840
340
1315
1245
1090
850
745
1640
1480
995
1200
565
1725
1560
1350
1140
895
1610
1450
1590
995
1170
1.0
630
570
280
230
-6
1135
1000
620
785
285
1235
1160
1050
800
690
1515
1415
950
1150
495
1605
1485
1300
1095
830
1500
1390
1470
930
1130
NOTE:
1. A filter is required for each return ---air inlet. Airflow performance includes a 3/4 ---in. (19 mm) washable filter media such as contained in a factory ---authorized accessory filter rack. See accessory list. To determine airflow performance without this filter, assume an additional 0.1 in. w.c. available external static
pressure.
2. ADJUST THE BLOWER SPEED TAPS AS NECESSARY FOR THE PROPER AIR TEMPERATURE RISE FOR EACH INSTALLATION.
3. Shaded areas indicate that this airflow range is BELOW THE RANGE ALLOWED FOR HIGH --- STAGE HEATING OPERATION. THESE AIRFLOW RANGES
MAY ONLY BE USED FOR LOW --- STAGE HEAT OR COOLING.
4. Airflows over 1800 CFM require bottom return, two ---side return, or bottom and side return. A minimum filter size of 20” x 25” (508 x 635 mm) is required.
5. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return.
6. The “ ---” entry indicates an unstable operating condition.
6
Two Stage
Furnace High
Heat Input
Winter Design
Temp ° F (° C)
20 (-10)
0 (-20)
40000*
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
60000
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
80000
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
100000
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
120000
-20 (-30)
-40 (-40)
Pipe
Length in
Ft. & M
No Insulation
3/8-in. (9.5 mm)
1/2-in. (12.7 mm)
Pipe Diameter-inches (mm)
Pipe Diameter-inches (mm)
Pipe Diameter-inches (mm)
1.5
2.0
2.5
3.0
4.0
1.5
2.0
2.5
3.0
4.0
1.5
2.0
2.5
3.0
4.0
(38)
(51)
(64)
(76)
(102)
(38)
(51)
(64)
(76)
(102)
(38)
(51)
(64)
(76)
(102)
Ft.
40.0
35.0
35.0
N/A
N/A
50.0
104.0
94.0
N/A
N/A
50.0
122.0 110.0
N/A
N/A
M
12.2
10.7
10.7
N/A
N/A
15.2
31.7
28.7
N/A
N/A
15.2
37.2
33.5
N/A
N/A
Ft.
19.0
14.0
12.0
N/A
N/A
50.0
61.0
54.0
N/A
N/A
50.0
74.0
65.0
N/A
N/A
M
5.8
4.3
3.7
N/A
N/A
15.2
18.6
16.5
N/A
N/A
15.2
22.6
19.8
N/A
N/A
Ft.
9.0
3.0
1.0
N/A
N/A
50.0
41.0
35.0
N/A
N/A
50.0
51.0
43.0
N/A
N/A
M
2.7
0.9
0.3
N/A
N/A
15.2
12.5
10.7
N/A
N/A
15.2
15.5
13.1
N/A
N/A
Ft.
3.0
0.0
0.0
N/A
N/A
39.0
29.0
23.0
N/A
N/A
48.0
37.0
30.0
N/A
N/A
M
0.9
0.0
0.0
N/A
N/A
11.9
8.8
7.0
N/A
N/A
14.6
11.3
9.1
N/A
N/A
Ft.
30.0
51.0
51.0
45.0
N/A
30.0
135.0 138.0 120.0
N/A
30.0
135.0 162.0 141.0
N/A
M
9.1
15.5
15.5
13.7
N/A
9.1
41.1
42.1
36.6
N/A
9.1
41.1
49.4
43.0
N/A
Ft.
30.0
24.0
23.0
16.0
N/A
30.0
93.0
82.0
69.0
N/A
30.0
111.0
98.0
83.0
N/A
M
9.1
7.3
7.0
4.9
N/A
9.1
28.3
25.0
21.0
N/A
9.1
33.8
29.9
25.3
N/A
Ft.
18.0
11.0
9.0
1.0
N/A
30.0
65.0
56.0
44.0
N/A
30.0
79.0
68.0
55.0
N/A
M
5.5
3.4
2.7
0.3
N/A
9.1
19.8
17.1
13.4
N/A
9.1
24.1
20.7
16.8
N/A
Ft.
10.0
3.0
0.0
0.0
N/A
30.0
48.0
40.0
29.0
N/A
30.0
59.0
50.0
38.0
N/A
M
3.0
0.9
0.0
0.0
N/A
9.1
14.6
12.2
8.8
N/A
9.1
18.0
15.2
11.6
N/A
Ft.
20.0
64.0
64.0
56.0
47.0
20.0
70.0
173.0 150.0 125.0
20.0
70.0
175.0 177.0 147.0
M
6.1
19.5
19.5
17.1
14.3
6.1
21.3
52.7
45.7
38.1
6.1
21.3
53.3
53.9
44.8
Ft.
20.0
32.0
30.0
22.0
11.0
20.0
70.0
104.0
87.0
67.0
20.0
70.0
124.0 104.0
82.0
M
6.1
9.8
9.1
6.7
3.4
6.1
21.3
31.7
26.5
20.4
6.1
21.3
37.8
31.7
25.0
Ft.
20.0
17.0
14.0
6.0
0.0
20.0
70.0
71.0
57.0
40.0
20.0
70.0
86.0
71.0
52.0
M
6.1
5.2
4.3
1.8
0.0
6.1
21.3
21.6
17.4
12.2
6.1
21.3
26.2
21.6
15.8
Ft.
15.0
7.0
5.0
0.0
0.0
20.0
61.0
52.0
40.0
24.0
20.0
70.0
64.0
50.0
33.0
M
4.6
2.1
1.5
0.0
0.0
6.1
18.6
15.8
12.2
7.3
6.1
21.3
19.5
15.2
10.1
Ft.
N/A
25.0
79.0
70.0
59.0
N/A
25.0
110.0 186.0 155.0
N/A
25.0
110.0 219.0 182.0
M
N/A
7.6
24.1
21.3
18.0
N/A
7.6
33.5
56.7
47.2
N/A
7.6
33.5
Ft.
N/A
25.0
40.0
31.0
19.0
N/A
25.0
110.0 109.0
86.0
N/A
25.0
110.0 131.0 104.0
66.8
55.5
M
N/A
7.6
12.2
9.4
5.8
N/A
7.6
33.5
33.2
26.2
N/A
7.6
33.5
39.9
31.7
Ft.
N/A
23.0
21.0
13.0
0.0
N/A
25.0
91.0
74.0
54.0
N/A
25.0
110.0
90.0
68.0
M
N/A
7.0
6.4
4.0
0.0
N/A
7.6
27.7
22.6
16.5
N/A
7.6
33.5
27.4
20.7
Ft.
N/A
13.0
10.0
1.0
0.0
N/A
25.0
68.0
53.0
35.0
N/A
25.0
83.0
66.0
46.0
M
N/A
4.0
3.0
0.3
0.0
N/A
7.6
20.7
16.2
10.7
N/A
7.6
25.3
20.1
14.0
Ft.
N/A
N/A
15.0
85.0
73.0
N/A
N/A
15.0
100.0 190.0
N/A
N/A
15.0
100.0 224.0
M
N/A
N/A
4.6
25.9
22.3
N/A
N/A
4.6
30.5
57.9
N/A
N/A
4.6
30.5
Ft.
N/A
N/A
15.0
41.0
29.0
N/A
N/A
15.0
100.0 109.0
N/A
N/A
15.0
100.0 131.0
68.3
M
N/A
N/A
4.6
12.5
8.8
N/A
N/A
4.6
30.5
33.2
N/A
N/A
4.6
30.5
39.9
Ft.
N/A
N/A
15.0
20.0
7.0
N/A
N/A
15.0
94.0
71.0
N/A
N/A
15.0
114.0
88.0
M
N/A
N/A
4.6
6.1
2.1
N/A
N/A
4.6
28.7
21.6
N/A
N/A
4.6
34.7
26.8
Ft.
N/A
N/A
15.0
7.0
0.0
N/A
N/A
15.0
69.0
48.0
N/A
N/A
15.0
85.0
62.0
M
N/A
N/A
4.6
2.1
0.0
N/A
N/A
4.6
21.0
14.6
N/A
N/A
4.6
25.9
18.9
* Not all families have these models.
* Pipe length (ft) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipe
length calculated from Table 1 or 3.
† Insulation thickness based on R value of 3.5 per in.
7
PG95XAT
MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE - FT. / M
MAXIMUM EQUIVALENT VENT LENGTH - FT. (M)
NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows.
Use Table NO TAG - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
Table 1 – Maximum Equivalent Vent Length -- Ft. (M)
0 to 4500 Ft. (0 to 1370 M) Altitude
Altitude
FT (M)
PG95XAT
0 to 2000
(0 to 610)
2001 to 3000
(610 to 914)
3001 to 4000
(914 to 1219)
4001 to 4500
(1219 to
1370)
Unit Size
BTU/Hr
40,000 3
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
DIRECT VENT (2-PIPE) AND NON-DIRECT VENT (1-PIPE)
50
30
20
NA
NA
NA
45
27
17
NA
NA
NA
39
23
15
NA
NA
NA
36
21
14
NA
NA
NA
1-1/2
(15.2)
(9.1)
(6.1)
(13.7)
(8.2)
(5.2)
(11.9)
(7.0)
(4.6)
(11.0)
(6.4)
(4.3)
210
135
70
25
NA
NA
198
127
64
22
NA
NA
184
119
59
19
NA
NA
177
115
56
17
NA
NA
Vent Pipe Diameter (in.) 1
2
2-1/2
3
(64.0)
250
(76.2)
NA 2
(41.1)
235
(71.6)
265
(80.8)
(21.3)
175
(53.3)
235
(71.6)
(7.6)
110
(33.5)
235
(71.6)
15
(4.6)
100
(30.5)
10
(3.0)
90
(27.4)
(60.4)
232
(70.7)
NA
(38.7)
222
(67.7)
250
(76.2)
(19.5)
165
(50.3)
222
(67.7)
(6.7)
104
(31.7)
223
(68.0)
11
(3.4)
93
(28.3)
NA
80
(24.4)
(56.1)
214
(65.2)
NA
(36.3)
210
(64.0)
235
(71.6)
(18.0)
155
(47.2)
210
(64.0)
(5.8)
98
(29.9)
211
(64.3)
8
(2.4)
86
(26.2)
NA
79
(24.1)
(53.9)
205
(62.5)
NA
(35.1)
204
(62.2)
228
(69.5)
(17.1)
150
(45.7)
202
(61.6)
(5.2)
94
(28.7)
205
(62.5)
NA
83
(25.3)
NA
69
(21.0)
4
NA
NA
265
265
250
210
NA
NA
249
250
237
185
NA
NA
232
236
224
158
NA
NA
224
229
217
146
(80.8)
(80.8)
(76.2)
(64.0)
(75.9)
(76.2)
(72.2)
(56.4)
(70.7)
(71.9)
(68.3)
(48.2)
(68.3)
(69.8)
(66.1)
(44.5)
NOTES: See notes at end of venting tables.
See Table NO TAG for altitudes over 4500 ft. (1370 M)
ELBOW CONFIGURATIONS
VENT TERMINAL CONFIGURATIONS
Concentric
Long
Medium
Mitered
Standard
A11580
8
MAXIMUM EQUIVALENT VENT LENGTH - FT. (M) (CONTINUED)
Table 2 – Deductions from Maximum Equivalent Vent Length -- Ft. (M)
Pipe Diameter (in):
1-1/2
2
2-1/2
3
4
Mitered 90º Elbow
8
(2.4)
8
(2.4)
8
(2.4)
8
(2.4)
8
(2.4)
Medium Radius 90º Elbow
5
(1.5)
5
(1.5)
5
(1.5)
5
(1.5)
5
(1.5)
Long Radius 90º Elbow
3
(0.9)
3
(0.9)
3
(0.9)
3
(0.9)
3
(0.9)
Mitered 45º Elbow
4
(1.2)
4
(1.2)
4
(1.2)
4
(1.2)
4
(1.2)
Medium Radius 45º Elbow
2.5
(0.8)
2.5
(0.8)
2.5
(0.8)
2.5
(0.8)
2.5
(0.8)
Long Radius 45º Elbow
1.5
(0.5)
1.5
(0.5)
1.5
(0.5)
1.5
(0.5)
1.5
(0.5)
Tee
16
(4.9)
16
(4.9)
16
(4.9)
16
(4.9)
16
0
(0.0)
0
(0.0)
0
(0.0)
0
(0.0)
Concentric Vent Termination
Standard Vent Termination
NA
0
(0.0)
NA
0
(0.0)
(4.9)
NA
0
(0.0)
The maximum length for each vent pipe (inlet or exhaust) equals the Maximum Equivalent Vent Length (MEVL) from Table NO TAG or
Table NO TAG minus the number of elbows multiplied by the deduction for each elbow in Table NO TAG.
Standard vent terminations and concentric vent terminations count for zero deductions.
See Vent Manufacturers’ data for equivalent lengths of flexible vent piping.
DO NOT ASSUME that one foot of flexible vent pipe is equivalent to one foot of standard PVC vent pipe.
Example
A direct--vent 60,000 Btuh furnace installed at 2100 ft. (640 M) with 2--in.(51 mm) vent piping. Venting system includes, FOR EACH
PIPE, (3) 90_ long radius elbows, (2) 45_ long radius elbows and a concentric vent kit.
Maximum Equivalent Vent Length
Deduct (3) 90 long radius
Deduct (2) 45 long radius
No deduction for Concentric Vent Kit
Maximum Vent Length
3
2
x
x
=
=
=
=
=
3 ft.
1.5 ft.
0 ft.
9
127 ft.
- 9 ft.
- 3 ft.
- 0 ft.
115 ft.
(From Table NO TAG)
(From Table NO TAG)
(From Table NO TAG)
(From Table NO TAG)
For EACH vent or inlet pipe
PG95XAT
Venting System Length Calculations
MAXIMUM EQUIVALENT VENT LENGTH - FT. (M) (CONTINUED)
NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows.
Use Table NO TAG - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
Table 3 – Maximum Equivalent Vent Length -- Ft. (M)
4501 to 10,000 Ft. (0 to 1370 M) Altitude
Altitude
FT (M) 5
PG95XAT
4501 to 5000
(1370 to
1524)
5001 to 6000
(1524 to
1829)
6001 to 7000
(1829 to
2134)
7001 to 8000
(2134 to
2438)
8001 to 9000
(2438 to
2743)
9001 to
10,000
(2743 to
3048)
DIRECT VENT (2-PIPE) AND SINGLE-PIPE
Vent Pipe Diameter (in.) 1
2
2-1/2
3
Unit Size
1-1/2
40,000
33
(10.1)
171
(52.1)
196
(59.7)
NA 2
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
20
13
NA
NA
NA
27
16
11
NA
NA
NA
21
13
NA
NA
NA
NA
15
10
NA
NA
NA
NA
10
7
NA
NA
NA
NA
5
NA
NA
NA
NA
NA
(6.1)
(4.0)
111
54
16
NA
NA
158
103
49
12
NA
NA
145
96
44
10
NA
NA
133
89
40
NA
NA
NA
121
82
35
NA
NA
NA
110
76
31
NA
NA
NA
(33.8)
(16.5)
(4.9)
198
146
91
NA
NA
179
186
137
85
NA
NA
162
174
120
79
NA
NA
146
163
120
73
NA
NA
130
152
111
67
NA
NA
115
142
103
62
NA
NA
(60.4)
(44.5)
(27.7)
221
195
200
80
60
NA
207
183
188
74
50
NA
194
171
178
68
41
NA
181
159
167
62
32
NA
168
148
157
56
23
NA
156
137
147
51
16
(8.2)
(4.9)
(3.4)
(6.4)
(4.0)
(4.6)
(3.0)
(3.0)
(2.1)
(1.5)
(48.2)
(31.4)
(14.9)
(3.7)
(44.2)
(29.3)
(13.4)
(3.0)
(40.5)
(27.1)
(12.2)
(36.9)
(25.0)
(10.7)
(33.5)
(23.2)
(9.4)
(54.6)
(56.7)
(41.8)
(25.9)
(49.4)
(53.0)
(36.6)
(24.1)
(44.5)
(49.7)
(36.6)
(22.3)
(39.6)
(46.3)
(33.8)
(20.4)
(35.1)
(43.3)
(31.4)
(18.9)
4
NA
(67.4)
(59.4)
(61.0)
(24.4)
(18.3)
(63.1)
(55.8)
(57.3)
(22.6)
(15.2)
(59.1)
(52.1)
(54.3)
(20.7)
(12.5)
(55.2)
(48.5)
(50.9)
(18.9)
(9.8)
(51.2)
(45.1)
(47.9)
(17.1)
(7.0)
(47.5)
(41.8)
(44.8)
(15.5)
(4.9)
NA
216
222
211
134
NA
NA
200
208
199
109
NA
NA
185
195
187
87
NA
NA
170
182
175
63
NA
NA
156
170
164
42
NA
NA
142
157
153
20
(65.8)
(67.7)
(64.3)
(40.8)
(61.0)
(63.4)
(60.7)
(33.2)
(56.4)
(59.4)
(57.0)
(26.5)
(51.8)
(55.5)
(53.3)
(19.2)
(47.5)
(51.8)
(50.0)
(12.8)
(43.3)
(47.9)
(46.6)
(6.1)
NOTES:
1. Use only the vent pipe sizes shown for each furnace. It is NOT necessary to choose the smallest diameter pipe possible for venting.
2. NA --- Not allowed. Pressure switch will not close, or flame disturbance may result.
3. Total equivalent vent lengths under 10’ for 40,000 BTUH furnaces from 0 to 2000 ft. (0 to 610 M) above sea level require use of an outlet choke plate .
Failure to use an outlet choke when required may result in flame disturbance or flame sense lockout.
4. Not all furnace families include 140,000 BTUH input models.
5. Vent sizing for Canadian installations over 4500 ft (1370 M) above sea level are subject to acceptance by local authorities having jurisdiction.
6. Size both the combustion air and vent pipe independently, then use the larger size for both pipes.
7. Assume the two 45_ elbows equal one 90_ elbow. Wide radius elbows are desirable and may be required in some cases.
8. Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
9. The minimum pipe length is 5 ft. (1.5 M) linear feet (meters) for all applications.
10. Use 3 ---in. (76 mm) diameter vent termination kit for installations requiring 4 ---in. (102 mm) diameter pipe.
10
RETURN AIR TEMPERATURE
This furnace is designed for continuous return--air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C)
db such as when used with a night setback thermometer. Return--air temperature must not exceed 80_F (27_C) db. Failure to follow these
return air limits may affect reliability of heat exchangers, motors and controls.
80
/ 27˚C
60
/ 16˚C
PG95XAT
SUPPLY AIR
A10490
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
POSITION
Rear
Front (Combustion air openings in furnace and in structure)
Required for service
All Sides of Supply Plenum
Sides
Vent
Top of Furnace
CLEARANCE
0 (0 mm)
1 in. (25 mm)
*24 in. (610 mm)
1 in. (25 mm)
0 (0 mm)
0 (0 mm)
1 in. (25 mm)
* Recommended
COMBUSTION--AIR PIPE FOR NON--DIRECT (1--PIPE) VENT APPLICATION
FIELD-SUPPLIED
2-IN. (51 mm) DIA.
TIGHT RADIUS
PVC 90° ELBOW
FIELD-SUPPLIED
2-IN. (51 mm) DIA.
PVC PIPE
12” (300 mm) Minimum
A11487
11
DOWNFLOW SUBBASE
LOCATING
TAB
1 1/4-IN. TYP
PLENUM
OPENING
B
A
D
1
2
3
4
LOCATING
TAB
C
FACTORY-SUPPLIED
FIELD-INSTALLED
INSULATION
4
PG95XAT
A97427
3
2
1
A88207
Assembled
Disassembled
DIMENSIONS (IN. / MM)
PLENUM OPENING*
FLOOR OPENING
HOLE NO. FOR
WIDTH
ADJUSTMENT
FURNACE
CASING WIDTH
FURNACE IN DOWNFLOW
APPLICATION
B
C
D
17--- 1/2 (444.5)
Furnace with or without Cased Coil
Assembly or Coil Box
15--- 1/8
(384.2)
19 (482.6)
16--- 3/4
(425.5)
20--- 3/8
(517.5)
3
21 (533.4)
Furnace with or without Cased Coil
Assembly or Coil Box
18--- 5/8
(396.4)
19 (482.6)
20--- 1/4
(514.4)
20--- 3/8
(517.5)
2
24--- 1/2 (622.3)
Furnace with or without Cased Coil
Assembly or Coil Box
22--- 1/8
(562.0)
19 (482.6)
23--- 3/4
(603.3)
20--- 3/8
(517.5)
1
A
*The plenum should be constructed 1/4 ---in. (6 mm) smaller in width and depth than the plenum dimensions shown above.
Concentric Vent Kit
Downflow Subbase
A93086
A88202
A concentric vent kit allows vent and combustion--air pipes to
terminate through a single exit in a roof or side wall. One pipe
runs inside the other allowing venting through the inner pipe and
combustion air to be drawn in through the outer pipe.
One base fits all furnace sizes. The base is designed to be installed
between the furnace and a combustible floor when no coil box is
used or when a coil box other than a Payne cased coil is used. It is
CSA design certified for use with Payne branded furnaces when
installed in downflow applications.
12
TYPICAL WIRING SCHEMATIC
FIELD 24-VOLT WIRING
FIELD 115-, 208/230-, 460-VOLT WIRING
FACTORY 24-VOLT WIRING
FACTORY 115-VOLT WIRING
NOTE 2
W
FIVE
WIRE
Y
R
G
1-STAGE
THERMOSTAT
TERMINALS
FIELD-SUPPLIED
FUSED DISCONNECT
THREE-WIRE
HEATINGONLY
BLK
BLK
WHT
WHT
GND
115-VOLT FIELD- JUNCTION
SUPPLIED
BOX
FUSED
DISCONNECT
C
O
N
T
R
O
L
208/230- OR
460-VOLT
THREE
PHASE
W2
COM
W/W1
Y/Y2
NOTE 1
R
GND
CONDENSING
UNIT
G
24-VOLT
TERMINAL
BLOCK
FURNACE
208/230VOLT
SINGLE
PHASE
PG95XAT
BLOWER
DOOR
SWITCH
C
NOTES: 1. Connect Y/Y2-terminal as shown for proper operation.
2. Some thermostats require a "C" terminal connection as shown.
3. If any of the original wire, as supplied, must be replaced, use
same type or equivalent wire.
A11401
13
PG95XAT
DIMENSIONAL DRAWING
A11611
14
GUIDE SPECIFICATIONS
System Description
Furnish a ______________________ 4--way multipoise gas--fired
condensing furnace for use with natural gas or propane (factory-authorized conversion kit required for propane); furnish cold air
return plenum; furnish external media cabinet for use with
accessory media filter or standard filter.
Quality Assurance
Unit will be designed, tested and constructed to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be third party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit
will carry the CSA Blue StarR and Blue FlameR
labels. Unit
efficiency testing will be performed per the current DOE test
procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the
latest AHRI Consumer’s Directory of Certified Efficiency Ratings.
Unit will carry the current Federal Trade Commission Energy
Guide efficiency label.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon request.
Equipment
Blower Wheel and ECM Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and
dynamically balanced. Blower motor of ECM type shall be
permanently lubricated with sealed ball bearings, of _______hp,
and have multiple speeds from 600--1200 RPM operating only
when motor inputs are provided. Blower motor shall be direct
drive and soft mounted to the blower scroll to reduce vibration
transmission.
Filters
Furnace shall have reusable--type filters. Filter shall be ______ in.
(mm) X ________ in. (mm). An accessory highly efficient Media
Filter is available as an option. _____________ Media Filter.
Casing
Casing shall be of .030 in. thickness minimum, pre--painted
galvanized steel.
Draft Inducer Motor
Draft inducer motor shall be two--speed design.
Primary Heat Exchangers
Primary heat exchangers shall be 3--Pass corrosion--resistant
aluminized steel of fold--and--crimp sectional design and applied
operating under negative pressure.
Secondary Heat Exchangers
Secondary heat exchangers shall be of a stainless steel
flow--through of fin--and--tube design and applied operating under
negative pressure.
Controls
Controls shall include a micro--processor--based integrated
electronic control board with at least 16 service troubleshooting
codes displayed via diagnostic flashing LED light on the control, a
self--test feature that checks all major functions of the furnace, and
a replaceable automotive--type circuit protection fuse. Multiple
operational settings available, including blower speeds for low
heat, high heat, low cooling, high cooling and continuous fan.
Continuous fan speed may be adjusted from the thermostat.
Cooling airflow will be selectable between 325 and 400 CFM per
ton of air conditioning.
Operating Characteristics
Heating capacity shall be _________________ Btuh input;
______________ Btuh output capacity.
Fuel Gas Efficiency shall be __________ AFUE.
Air delivery shall be ________________ cfm minimum at 0.50 in.
W.C.. external static pressure.
Dimensions shall be: depth_________in. (mm); width
__________in. (mm); height___________in. (mm) (casing only).
Height shall be _________in. (mm) with A/C coil and
_________________in. (mm) overall with plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal).
Minimum wire size shall be ________AWG; maximum fuse size
of HACR--type designated circuit breaker shall be _________
amps.
Special Features
Refer to section of the product data identifying accessories and
descriptions for specific features and available enhancements.
15
PG95XAT
General
PG95XAT
E2012 Payne Heating & Cooling Systems D
7310 W. Morris St. D Indianapolis, IN 46231
Printed in U.S.A.
Edition Date: 01/12
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
16
Catalog No: SS---PG95XAT ---03
Replaces: SS--- PG95XAT--- 02
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising