Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Rosemount 3051S Series of Instrumentation
Scalable Pressure, Flow, and Level Solutions
• 3051S Series delivers highest field
performance and reliability
• SuperModule® Platform provides a foundation
for integrated pressure, flow, and level
solutions
• IEC 62591 (WirelessHART™) Protocol
enables cost effective installations
• MultiVariable™ technology enables fully
compensated mass and energy flow
• Advanced Diagnostics provides coverage
from the process to the host system
• Innovative DP Flowmeters integrate a primary
element and transmitter into a single device
• Electronic Remote Sensors and
Tuned-System™ Assemblies provide cost
efficient, optimized level measurement
Contents
Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2
Ordering Information
Rosemount 3051S Scalable Coplanar Pressure Transmitter . . . . . . . . . . . . . page 4
Rosemount 3051S Scalable In-Line Pressure Transmitter . . . . . . . . . . . . . . page 11
Rosemount 3051S Scalable MultiVariable Transmitter . . . . . . . . . . . . . . . . . page 16
Rosemount 3051SF DP Flowmeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22
Rosemount 3051S Electronic Remote Sensors . . . . . . . . . . . . . . . . . . . . . . page 44
Rosemount 3051S Liquid Level Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . page 53
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 68
Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 86
Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 98
www.rosemount.com
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
Achieve More with Rosemount 3051S Series of Instrumentation
The Foundation for Pressure, Flow, and Level
Measurement
• SuperModule® Platform delivers the highest field
reliability with all-welded hermetic SST design
• Ultra and Ultra for Flow provide industry leading
performance, 10-year stability, and a 12-year limited
warranty
• Simplify compliance with IEC 61508 safety
certification
The World’s Only Scalable Platform
•
Optimize performance, functionality, and process connections for your
application
•
MultiVariable, Advanced Diagnostics, Wireless, Electronic Remote Sensors, and
enhanced FOUNDATION™ fieldbus capabilities enable better plant performance
•
Seamless integration of flanges, manifolds, remote mount seals, and flow
elements
Industry Leading Capabilities Extended To IEC 62591 (WirelessHART)
• Cost effectively implement wireless on the proven SuperModule platform
• Realize a decade of virtually maintenance-free performance
• Optimize safety with the industry’s only intrinsically safe Power Module
• Implement wireless using existing tools and practices
• Installation-ready integrated wireless pressure, flow, and level solutions
Advanced Diagnostics Provides Coverage from the Process to the Host
• Proactively monitor for loop wiring and power supply issues
• Predict and prevent abnormal process conditions
• Log process characteristics and device health
• Extend diagnostic coverage to Safety Instrumented Systems
2
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Advanced MultiVariable Technology
•
Dynamically calculate mass or volumetric, energy, and totalized flow through
real time compensation of over 25 variables
•
Customize the level of compensation with the scalable platform
•
Easily configure flow and device parameters with Engineering Assistant™
software.
•
Achieve up to ±0.65% flow accuracy over a 14:1 flow turndown
Innovative, Integrated DP Flowmeters
•
Fully assembled and leak tested for out-of-the-box installation
•
Lower installed costs by replacing 10 devices with one integrated flowmeter
•
Reduce straight pipe requirements, lower permanent pressure loss, and
achieve accurate measurement in small line sizes
•
Measure up to 14:1 flow turndown with % of reading performance
Proven, Reliable, and Innovative DP Level Technologies
•
Connect to virtually any process with a comprehensive offering of process
connections, fill fluids, direct mount or capillary connections, and materials
•
Quantify and optimize total system performance with QZ option
•
Achieve success on tall vessels and distillation towers with Electronic Remote
Sensor digital architecture
•
Optimize level measurement with cost efficient Tuned-System Assemblies
Instrument Manifolds – Quality, Convenient, and Easy
•
Designed and engineered for optimal performance with Rosemount
transmitters
•
Save installation time and money with factory assembled manifolds
•
Offers a variety of styles, materials, and configurations
•
Enable “flange-less” valve integration with Coplanar™ design
3
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Rosemount 3051S Scalable Coplanar Pressure Transmitter
Rosemount 3051S Scalable Coplanar Pressure transmitters are the industry
leader for Differential, Gage, and Absolute pressure measurement. The
coplanar platform allows seamless integration with manifolds, primary
elements, and seal solutions. Capabilities include:
• Ultra, Ultra for Flow, and Classic Performance
• HART/4-20 mA, Wireless, FOUNDATION fieldbus protocols
• Safety Certification (Option Code QT)
• Advanced Diagnostics (Option Code DA2)
• Remote Display and Interface (Option Code M7, M8, or M9)
3051S Scalable Coplanar
Pressure Transmitter
Additional Information
Specifications: page 68
Certifications: page 86
Dimensional Drawings: page 98
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter Type
3051S
Scalable Pressure Transmitter
Performance Class
Standard
1
Ultra: 0.025 percent span accuracy, 200:1 rangedown, 10-yr stability, 12-yr limited warranty
3(1)
Ultra for Flow: 0.04 percent reading accuracy, 200:1 turndown, 10-yr stability, 12-yr ltd warranty
2
Classic: 0.055 percent span accuracy, 100:1 rangedown, 5-yr stability
Connection Type
Standard
C
Coplanar
Measurement Type(2)
Standard
D
Differential
G
Gage
Expanded
A
Absolute
Pressure Range
Differential
Gage
Absolute
Standard
1A
-25 to 25 inH2O (-62,2 to 62,2 mbar) -25 to 25 inH2O (-62,2 to 62,2 mbar) 0 to 30 psia (0 to 2,06 bar)
2A
-250 to 250 inH2O (-623 to
-250 to 250 inH2O (-623 to 623 mbar) 0 to 150 psia (0 to 10,34 bar)
623 mbar)
3A
-1000 to 1000 inH2O (-2,5 to 2,5 bar) -393 to 1000 inH2O (-0,98 to 2,5 bar) 0 to 800 psia (0 to 55,2 bar)
4A
-300 to 300 psi (-20,7 to 20,7 bar)
-14.2 to 300 psig (-0,98 to 21 bar)
0 to 4000 psia (0 to 275,8 bar)
5A
-2000 to 2000 psi (-137,9 to 137,9
-14.2 to 2000 psig (-0,98 to 137,9
N/A
bar)
bar)
Expanded
0A(3)
-3 to 3 inH2O (-7,47 to 7,47 mbar)
N/A
0 to 5 psia (0 to 0,34 bar)
Isolating Diaphragm
Standard
2(4)
316L SST
3(4)
Alloy C-276
Expanded
4
Alloy 400
5(5)
Tantalum
6
Gold-Plated Alloy 400 (includes Graphite-Filled PTFE o-ring)
7
Gold-plated 316L SST
4
Standard
★
★
★
Standard
★
Standard
★
★
Standard
★
★
★
★
★
Standard
★
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Process Connection
Size
Materials of Construction
Flange
Material
Standard
000
A11(6)
A12(6)
B11(6)(7)(8)
B12(6)(7)(8)
C11(6)
D11(6)
EA2(6)
EA3(6)
EA5(6)
Drain Vent
None
Assemble to Rosemount 305 Integral Manifold
Assemble to Rosemount 304 or AMF Manifold and SST traditional flange
Assemble to one Rosemount 1199 Seal
SST
Assemble to two Rosemount 1199 Seals
SST
Assemble to Rosemount 405 Primary Element
Assemble to Rosemount 1195 integral orifice and Rosemount 305 Integral Manifold
Assemble to Rosemount Annubar® Primary Element with
SST
316 SST
Coplanar flange
Assemble to Rosemount Annubar Primary Element with
Cast C-276
Alloy C-276
Coplanar flange
Assemble to Rosemount Annubar Primary Element with
SST
Alloy C-276
Coplanar flange
1
Coplanar flange
/4–18 NPT
CS
316 SST
1
Coplanar flange
/4–18 NPT
SST
316 SST
1
Coplanar flange
/4–18 NPT
Cast C-276
Alloy C-276
1
Coplanar flange
/4–18 NPT
Cast Alloy 400 Alloy 400/K-500
1
Coplanar flange
/4–18 NPT
SST
Alloy C-276
1
Coplanar flange
/4–18 NPT
CS
Alloy C-276
Coplanar flange
RC 1/4
CS
316 SST
Coplanar flange
RC 1/4
SST
316 SST
Coplanar flange
RC 1/4
Cast C-276
Alloy C-276
Coplanar flange
RC 1/4
Cast Alloy 400 Alloy 400/K-500
Coplanar flange
RC 1/4
SST
Alloy C-276
Coplanar flange
RC 1/4
CS
Alloy C-276
1/4–18 NPT
Traditional flange
SST
316 SST
1/4–18 NPT
Traditional flange
Cast C-276
Alloy C-276
1/4–18 NPT
Traditional flange
Cast Alloy 400 Alloy 400/K-500
1
Traditional flange
/4–18 NPT
SST
Alloy C-276
Traditional flange
RC 1/4
SST
316 SST
Traditional flange
RC 1/4
Cast C-276
Alloy C-276
Traditional flange
RC 1/4
Cast Alloy 400 Alloy 400/K-500
Traditional flange
RC 1/4
SST
Alloy C-276
1
DIN-compliant traditional flange
/4–18 NPT
SST
316 SST
Vertical mount level flange
2-in. ANSI class 150 SST
316 SST
Vertical mount level flange
2-in. ANSI class 300 SST
316 SST
Vertical mount level flange
3-in. ANSI class 150 SST
316 SST
Vertical mount level flange
3-in. ANSI class 300 SST
316 SST
Vertical mount level flange
DIN- DN 50 PN 40
SST
316 SST
Vertical mount level flange
DIN- DN 80 PN 40
SST
316 SST
E11
E12
E13(4)
E14
E15(4)
E16(4)
E21
E22
E23(4)
E24
E25(4)
E26(4)
F12
F13(4)
F14
F15(4)
F22
F23(4)
F24
F25(4)
F52
G11
G12
G21
G22
G31
G41
Expanded
1/4–18 NPT
F32
Bottom vent traditional flange
SST
F42
Bottom vent traditional flange
RC 1/4
SST
1
F62
DIN-compliant traditional flange
/4–18 NPT
SST
1
F72
DIN-compliant traditional flange
/4–18 NPT
SST
Transmitter Output
Standard
A
4–20 mA with digital signal based on HART® protocol
(9)
F
FOUNDATION™ fieldbus protocol
X(10)
Wireless (Requires wireless options and wireless PlantWeb housing)
316 SST
316 SST
316 SST
316 SST
Bolting
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
7
/16-in. bolting
★
★
★
★
★
★
★
M10 bolting
M12 bolting
Standard
★
★
★
5
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Housing Style
Standard
00
1A
1B
1J
1K
5A(11)
5J(11)
2A
2B
2J
2E
2F
2M
7J(12)
Expanded
1C
1L
2C
2G
Material
Conduit
Entry Size
None (SuperModule spare part, order output code A)
PlantWeb housing
PlantWeb housing
PlantWeb housing
PlantWeb housing
Wireless PlantWeb housing
Wireless PlantWeb housing
Junction Box housing
Junction Box housing
Junction Box housing
Junction Box Housing with output for remote display and interface
Junction Box Housing with output for remote display and interface
Junction Box Housing with output for remote display and interface
Quick Connect (A size Mini, 4-pin male termination)
Aluminum
Aluminum
SST
SST
Aluminum
SST
Aluminum
Aluminum
SST
Aluminum
Aluminum
SST
SST
1
PlantWeb housing
PlantWeb housing
Junction Box housing
Junction Box Housing with output for remote display and interface
Aluminum
SST
Aluminum
Aluminum
G1/2
G1/2
G1/2
G1/2
/2–14 NPT
M20 x 1.5
1
/2–14 NPT
M20 x 1.5
1
/2–14 NPT
1
/2–14 NPT
1/2–14 NPT
M20 x 1.5
1
/2–14 NPT
1/2–14 NPT
M20 x 1.5
1
/2–14 NPT
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
Wireless Options (Requires option code X and wireless PlantWeb housing)
Update Rate
Standard
WA
User Configurable Update Rate
Operating Frequency and Protocol
Standard
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Omnidirectional Wireless Antenna
Standard
WK
External Antenna
WM
Extended Range, External Antenna
Expanded
WN
High-Gain, Remote Antenna
SmartPower™
Standard
Adapter for Black Power Module (I.S. Power Module Sold Separately)
1(13)
Standard
★
Standard
★
Standard
★
★
Standard
★
Other Options (Include with selected model number)
PlantWeb Control Functionality
Standard
FOUNDATION fieldbus Advanced Control Function Block Suite
A01(14)
PlantWeb Diagnostic Functionality
Standard
FOUNDATION fieldbus Diagnostics Suite
D01(14)
Advanced HART Diagnostics Suite
DA2(14)(15)
PlantWeb Enhanced Measurement Functionality
Standard
FOUNDATION fieldbus Fully Compensated Mass Flow Block
H01(14)(16)
Mounting Bracket(17)
Standard
B4
Coplanar flange bracket, all SST, 2-in. pipe and panel
B1
Traditional flange bracket, CS, 2-in. pipe
B2
Traditional flange bracket, CS, panel
B3
Traditional flange flat bracket, CS, 2-in. pipe
6
Standard
★
Standard
★
★
Standard
★
Standard
★
★
★
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
B7
Traditional flange bracket, B1 with SST bolts
B8
Traditional flange bracket, B2 with SST bolts
B9
Traditional flange bracket, B3 with SST bolts
BA
Traditional flange bracket, B1, all SST
BC
Traditional flange bracket, B3, all SST
Software Configuration
Standard
Custom software configuration (Requires Configuration Data Sheet)
C1(18)
C2
Custom flow configuration (Requires H01 and Configuration Data Sheet)
Gage Pressure Calibration
Standard
C3
Gage pressure calibration on Rosemount 3051S_CA4 only
Alarm Limit
Standard
NAMUR alarm and saturation levels, high alarm
C4(14)(18)
NAMUR alarm and saturation levels, low alarm
C5(14)(18)
Custom alarm and saturation signal levels, high alarm (Requires C1 and Configuration Data Sheet)
C6(14)(18)
Custom alarm and saturation signal levels, low alarm (Requires C1 and Configuration Data Sheet)
C7(14)(18)
Low alarm (standard Rosemount alarm and saturation levels)
C8(14)(18)
Hardware Adjustments
Standard
Hardware adjustments (zero, span, alarm, security)
D1(14)(18)(19)
Flange Adapter
Standard
1/2-14 NPT flange adapter
D2(17)
Expanded
RC1/2 SST flange adapter
D9(17)
Custody Transfer
Standard
Measurement Canada Accuracy Approval
D3(20)
Ground Screw
Standard
D4
External ground screw assembly
Drain/Vent Valve
Standard
Delete transmitter drain/vent valves (install plugs)
D5(17)
Expanded
SST Coplanar flange without drain/vent ports
D7(17)
Conduit Plug
Standard
316 SST Conduit Plug
DO(21)
Product Certifications(22)
Standard
E1
ATEX Flameproof
I1
ATEX Intrinsic Safety
IA
ATEX FISCO Intrinsic Safety (FOUNDATION™ fieldbus protocol only)
N1
ATEX Type n
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust
ND
ATEX Dust
E4
TIIS Flameproof
TIIS Intrinsic Safety
I4(11)
E5
FM Explosion-proof, Dust Ignition-proof
I5
FM Intrinsically Safe, Division 2
IE
FM FISCO Intrinsically Safe (FOUNDATION™ fieldbus protocol only)
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
★
★
★
★
★
Standard
★
★
Standard
★
Standard
★
★
★
★
★
Standard
★
Standard
★
Standard
★
Standard
★
Standard
★
Standard
★
Standard
★
★
★
★
★
★
★
★
★
★
★
★
7
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
CSA Explosion-proof, Dust Ignition-proof, Division 2
E6(23)
I6
CSA Intrinsically Safe
IF
CSA FISCO Intrinsically Safe (FOUNDATION™ fieldbus protocol only)
(23)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
K6
E7
IECEx Flameproof, Dust Ignition-proof
I7
IECEx Intrinsic Safety
IG
IECEx FISCO Intrinsic Safety (FOUNDATION™ fieldbus protocol only)
N7
IECEx Type n
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n
E2
INMETRO Flameproof
I2
INMETRO Intrinsic Safety
K2
INMETRO Flameproof, Intrinsic Safety
E3
China Flameproof
I3
China Intrinsic Safety
N3
China Type n
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
KA(23)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
KB(23)
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
KC
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
KD(23)
Shipboard Approvals
Standard
SBS
American Bureau of Shipping
Sensor Fill Fluid
Standard
Inert sensor fill fluid
L1(24)
O-ring
Standard
L2
Graphite-filled PTFE o-ring
Bolting Material
Standard
Austenitic 316 SST bolts
L4(17)
ASTM A 193, Grade B7M bolts
L5(4)(17)
Alloy K-500 bolts
L6(17)
ASTM A453, Class D, Grade 660 bolts
L7(4)(17)
ASTM A193, Class 2, Grade B8M bolts
L8(17)
Display Type(25)
Standard
M5
PlantWeb LCD Display
M7(14)(26)(27) Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracket
M8(14)(26)
Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15 m) cable, SST bracket
M9(14)(26)
Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31 m) cable, SST bracket
Pressure Testing
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
Standard
★
Standard
★
Standard
★
Standard
★
★
★
★
★
Standard
★
★
★
★
Expanded
P1(28)
Hydrostatic testing with certificate
Special Cleaning
Expanded
P2(17)
Cleaning for special services
P3(17)
Cleaning for less than 1PPM chlorine/fluorine
Maximum Static Line Pressure
Standard
P9
4500 psig (310 bar) static pressure limit (Rosemount 3051S_CD only)
P0(29)
6092 psig (420 bar) static pressure limit (Rosemount 3051S2CD only)
Calibration Certification
Standard
Q4
Calibration certificate
QP
Calibration certificate and tamper evident seal
8
Standard
★
★
Standard
★
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 1. Rosemount 3051S Scalable Coplanar Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Material Traceability Certification
Standard
Q8
Material traceability certification per EN 10204 3.1
Quality Certification for Safety
Standard
Prior-use certificate of FMEDA Data
QS(14)(18)
Safety-certified to IEC 61508 with certificate of FMEDA data
QT(30)
Transient Protection
Standard
Transient terminal block
T1(31)(32)
Drinking Water Approval
Standard
NSF Drinking Water Approval
DW(33)
Surface Finish Certification
Standard
Q16
Surface finish certification for sanitary remote seals
Toolkit Total System Performance Reports
Standard
QZ
Remote Seal System Performance Calculation Report
Conduit Electrical Connector
Standard
GE(34)
M12, 4-pin, Male Connector (eurofast®)
GM(34)
A size Mini, 4-pin, Male Connector (minifast®)
Typical Model Number: 3051S1CD 2A 2 E12 A 1A DA2 B4 M5
Standard
★
Standard
★
★
Standard
★
Standard
★
Standard
★
Standard
★
Standard
★
★
(1) This option is only available with range codes 2A and 3A, 316L SST or Alloy C-276 isolating diaphragm and silicone fill fluid.
(2) Performance Class code 3 is available with Measurement Type code D only.
(3) 3051S_CD0 is only available with traditional flange, 316L SST diaphragm material, and Bolting option L4.
(4) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
(5) Tantalum diaphragm material is only available for ranges 2A - 5A, differential and gage.
(6) “Assemble to” items are specified separately and require a completed model number. Process connection option codes B12, C11, D11, EA2, EA3, and
EA5 are only available on differential Measurement Type, code D.
(7) Consult an Emerson Process Management representative for performance specifications.
(8) Not available with performance class code 3.
(9) Requires PlantWeb housing.
(10) Available approvals are FM Intrinsically Safe, Division 2 (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety
(option code I1), and IECEx Intrinsic Safety (option code I7).
(11) Only available with output code X.
(12) Available with output code A only. Available approvals are FM Intrinsically Safe, Division 2 (option code I5), ATEX Intrinsic Safety (option code I1), or IECEx
Intrinsic Safety (option code I7). Contact an Emerson Process Management representative for additional information.
(13) Long-Life Power Module must be shipped separately, order Part #00753-9220-0001.
(14) Not available with output code X.
(15) Requires PlantWeb housing and output code A. Includes Hardware Adjustments as standard.
(16) Requires Rosemount Engineering Assistant to configure.
(17) Not available with process connection option code A11.
(18) Not available with output code F.
(19) Not available with housing style codes 00, 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
(20) Requires PlantWeb housing and Hardware Adjustments option code D1. Limited availability depending on transmitter type and range. Contact an Emerson
Process Management representative for additional information.
(21) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
9
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
(22) Valid when SuperModule Platform and housing have equivalent approvals.
(23) Not available with M20 or G ½ conduit entry size.
(24) Only available on differential and gage measurement types. Silicone fill fluid is standard.
(25) Not available with Housing code 7J.
(26) Not available with output code F, option code DA2, or option code QT.
(27) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management
representative for additional information.
(28) P1 is not available with 3051S_CA0.
(29) Requires 316L SST, Alloy C-276, or Gold-plated 316L SST diaphragm material, assemble to Rosemount 305 integral manifold or DIN-compliant traditional
flange process connection, and bolting option L8. Limited to Pressure Range (Differential), ranges 2A – 5A.
(30) Not available with output code F or X. Not available with housing code 7J.
(31) Not available with Housing code 00, 5A, 5J, or 7J.
(32) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IE, IF, and IG.
(33) Requires 316L SST diaphragm material, glass-filled PTFE O-ring (standard), and Process Connection code E12 or F12.
(34) Not available with Housing code 00, 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Division 2 (option code I5) or
FM FISCO Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009 to maintain outdoor rating (NEMA 4X and IP66).
10
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Rosemount 3051S Scalable In-Line Pressure Transmitter
Rosemount 3051S Scalable In-line Pressure transmitters are the industry
leader for Gage and Absolute pressure measurement. The in-line, compact
design allows the transmitter to be connected directly to a process for quick,
easy and cost effective installation. Capabilities include:
• Ultra and Classic Performance
• HART/4-20 mA, Wireless, FOUNDATION fieldbus protocols
• Safety Certification (Option Code QT)
3051S Scalable In-Line
Pressure Transmitter
• Advanced Diagnostics (Option Code DA2)
• Remote Display and Interface (Option Code M7, M8, or M9)
Additional Information
Specifications: page 68
Certifications: page 86
Dimensional Drawings: page 100
Table 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter Type
3051S
Scalable Pressure Transmitter
Performance Class
Standard
1
Ultra: 0.025 percent span accuracy, 200:1 rangedown, 10-yr stability, 12-yr limited warranty
2
Classic: 0.055 percent span accuracy, 100:1 rangedown, 5-yr stability
Connection Type
Standard
T
In-Line
Measurement Type
Standard
G
Gage
A
Absolute
Pressure Range
Gage
Absolute
Standard
1A
-14.7 to 30 psi (-1,0 to 2,1 bar)
0 to 30 psia (2,1 bar)
2A
-14.7 to 150 psi (-1,0 to 10,3 bar)
0 to 150 psia (10,3 bar)
3A
-14.7 to 800 psi (-1,0 to 55 bar)
0 to 800 psia (55 bar)
4A
-14.7 to 4000 psi (-1,0 to 276 bar)
0 to 4000 psia (276 bar)
5A
-14.7 to 10000 psi (-1,0 to 689 bar)
0 to 10000 psia (689 bar)
Isolating Diaphragm
Standard
2(1)
316L SST
3(1)
Alloy C-276
Process Connection
Standard
A11(2)
B11(2)(3)
E11
G11
Expanded
F11
Assemble to Rosemount 306 Integral Manifold
Assemble to one Rosemount 1199 Seal
1
/2–14 NPT female
G1/2 A DIN 16288 male (Range 1-4 only)
Standard
★
★
Standard
★
Standard
★
★
Standard
★
★
★
★
★
Standard
★
★
Standard
★
★
★
★
Non-threaded instrument flange (I-flange) (Range 1-4 only)
11
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
Table 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Transmitter Output
Standard
A
4–20 mA with digital signal based on HART® protocol
F(4)
FOUNDATION™ fieldbus protocol
(5)
X
Wireless (Requires wireless options and wireless PlantWeb housing)
Housing Style
Material
Conduit Entry Size
Standard
00
None (SuperModule spare part, order output code A)
1
1A
PlantWeb housing
Aluminum
/2–14 NPT
1B
PlantWeb housing
Aluminum
M20 x 1.5
1/2–14 NPT
1J
PlantWeb housing
SST
1K
PlantWeb housing
SST
M20 x 1.5
1
5A(6)
Wireless PlantWeb housing
Aluminum
/2–14 NPT
(6)
1
5J
Wireless PlantWeb housing
SST
/2–14 NPT
1
2A
Junction Box housing
Aluminum
/2–14 NPT
2B
Junction Box housing
Aluminum
M20 x 1.5
1/2–14 NPT
2J
Junction Box housing
SST
1
2E
Junction Box Housing with output for remote display and interface
Aluminum
/2–14 NPT
2F
Junction Box Housing with output for remote display and interface
Aluminum
M20 x 1.5
1/2–14 NPT
2M
Junction Box Housing with output for remote display and interface
SST
(7)
SST
7J
Quick Connect (A size Mini, 4-pin male termination)
Expanded
1C
PlantWeb housing
Aluminum
G1/2
1L
PlantWeb housing
SST
G1/2
2C
Junction Box housing
Aluminum
G1/2
2G
Junction Box Housing with output for remote display and interface
Aluminum
G1/2
Standard
★
★
★
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
Wireless Options (Requires option code X and wireless PlantWeb housing)
Update Rate
Standard
WA
User Configurable Update Rate
Operating Frequency and Protocol
Standard
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Omnidirectional Wireless Antenna
Standard
WK
External Antenna
WM
Extended Range, External Antenna
Expanded
WN
High-Gain, Remote Antenna
SmartPower™
Standard
1(8)
Adapter for Black Power Module (I.S. Power Module Sold Separately)
Standard
★
Standard
★
Standard
★
★
Standard
★
Other Options (Include with selected model number)
PlantWeb Control Functionality
Standard
A01(9)
FOUNDATION fieldbus Advanced Control Function Block Suite
PlantWeb Diagnostic Functionality
Standard
D01(9)
FOUNDATION fieldbus Diagnostics Suite
DA2(9)(10)
Advanced HART Diagnostics Suite
Mounting Bracket(11)
Standard
B4
Bracket, all SST, 2-in. pipe and panel
Software Configuration
Standard
C1(12)
Custom software configuration (Requires Configuration Data Sheet)
12
Standard
★
Standard
★
★
Standard
★
Standard
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Alarm Limit
Standard
C4(9)(12)
NAMUR alarm and saturation levels, high alarm
C5(9)(12)
NAMUR alarm and saturation levels, low alarm
C6(9)(12)
Custom alarm and saturation signal levels, high alarm (Requires C1 and Configuration Data Sheet)
C7(9)(12)
Custom alarm and saturation signal levels, low alarm (Requires C1 and Configuration Data Sheet)
C8(9)(12)
Low alarm (standard Rosemount alarm and saturation levels)
Hardware Adjustments
Standard
D1(9)(12)(13)
Hardware adjustments (zero, span, alarm, security)
Custody Transfer
Standard
D3(14)
Measurement Canada Accuracy Approval
Ground Screw
Standard
D4
External ground screw assembly
Conduit Plug
Standard
DO(15)
316 SST Conduit Plug
Product Certifications(16)
Standard
E1
ATEX Flameproof
I1
ATEX Intrinsic Safety
IA
ATEX FISCO Intrinsic Safety (FOUNDATION™ fieldbus protocol only)
N1
ATEX Type n
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust
ND
ATEX Dust
E4
TIIS Flameproof
I4(6)
TIIS Intrinsic Safety
E5
FM Explosion-proof, Dust Ignition-proof
I5
FM Intrinsically Safe, Division 2
IE
FM FISCO Intrinsically Safe (FOUNDATION™ fieldbus protocol only)
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
E6(17)
CSA Explosion-proof, Dust Ignition-proof, Division 2
I6
CSA Intrinsically Safe
IF
CSA FISCO Intrinsically Safe (FOUNDATION™ fieldbus protocol only)
(17)
K6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
E7
IECEx Flameproof, Dust Ignition-proof
I7
IECEx Intrinsic Safety
IG
IECEx FISCO Intrinsic Safety (FOUNDATION™ fieldbus protocol only)
N7
IECEx Type n
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n
E2
INMETRO Flameproof
I2
INMETRO Intrinsic Safety
K2
INMETRO Flameproof, Intrinsic Safety
E3
China Flameproof
I3
China Intrinsic Safety
N3
China Type n
KA(17)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
KB(17)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
KD(17)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
Shipboard Approvals
Standard
SBS
American Bureau of Shipping
Standard
★
★
★
★
★
Standard
★
Standard
★
Standard
★
Standard
★
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
Standard
★
13
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
Table 2. Rosemount 3051S Scalable In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Sensor Fill Fluid
Standard
L1(18)
Inert sensor fill fluid
Display Type(19)
Standard
M5
PlantWeb LCD Display
M7(9)(20)(21)
Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracket
M8(9)(20)
Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15 m) cable, SST bracket
M9(9)(20)
Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31 m) cable, SST bracket
Pressure Testing
Standard
★
Standard
★
★
★
★
Expanded
P1
Hydrostatic testing with certificate
Special Cleaning
Expanded
P2(11)
Cleaning for special services
P3(11)
Cleaning for less than 1PPM chlorine/fluorine
Calibration Certification
Standard
Q4
Calibration certificate
QP
Calibration certificate and tamper evident seal
Material Traceability Certification
Standard
Q8
Material traceability certification per EN 10204 3.1
Quality Certification for Safety
Standard
QS(9)(12)
Prior-use certificate of FMEDA Data
QT(22)
Safety-certified to IEC 61508 with certificate of FMEDA data
Transient Protection
Standard
T1(23)(24)
Transient terminal block
Drinking Water Approval
Standard
DW(25)
NSF Drinking Water Approval
Surface Finish Certification
Standard
Q16
Surface finish certification for sanitary remote seals
Toolkit Total System Performance Reports
Standard
QZ
Remote Seal System Performance Calculation Report
Conduit Electrical Connector
Standard
GE(26)
M12, 4-pin, Male Connector (eurofast®)
(26)
GM
A size Mini, 4-pin, Male Connector (minifast®)
Typical Model Number: 3051S1TG 2A 2 E11 A 1A DA2 B4 M5
Standard
★
★
Standard
★
Standard
★
★
Standard
★
Standard
★
Standard
★
Standard
★
Standard
★
★
(1) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
(2) “Assemble to” items are specified separately and require a completed model number.
(3) Consult an Emerson Process Management representative for performance specifications.
(4) Requires PlantWeb housing.
(5) Available approvals are FM Intrinsically Safe, Division 2 (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety
(option code I1), and IECEx Intrinsic Safety (option code I7).
(6) Only available with output code X.
14
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
(7) Available with output code A only. Available approvals are FM Intrinsically Safe, Division 2 (option code I5), ATEX Intrinsic Safety (option code I1), or IECEx
Intrinsic Safety (option code I7). Contact an Emerson Process Management representative for additional information.
(8) Long-Life Power Module must be shipped separately, order Part #00753-9220-0001.
(9) Not available with output code X.
(10) Requires PlantWeb housing and output code A. Includes Hardware Adjustments as standard.
(11) Not available with process connection option code A11.
(12) Not available with output code F.
(13) Not available with housing style codes 00, 01, 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
(14) Requires PlantWeb housing and Hardware Adjustments option code D1. Limited availability depending on transmitter type and range. Contact an Emerson
Process Management representative for additional information.
(15) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(16) Valid when SuperModule Platform and housing have equivalent approvals.
(17) Not available with M20 or G ½ conduit entry size.
(18) Silicone fill fluid is standard.
(19) Not available with Housing code 7J.
(20) Not available with output code F, option code DA2, or option code QT.
(21) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management
representative for additional information.
(22) Not available with output code F or X. Not available with housing code 7J.
(23) Not available with Housing code 00, 5A, 5J, or 7J.
(24) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IE, IF, and IG.
(25) Requires 316L SST diaphragm material and Process Connection code E11 or G11.
(26) Not available with Housing code 00, 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Division 2 (option code I5) or
FM FISCO Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009 to maintain outdoor rating (NEMA 4X and IP66).
15
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Rosemount 3051S Scalable MultiVariable Transmitter
The Rosemount 3051S Scalable MultiVariable Transmitter delivers
unprecedented performance and capabilities by providing superior flow
calculations including fully compensated mass or volume, energy, and totalized
flow. Specify the level of compensation that best matches the application:
• Gas, natural gas, and steam measurement: Utilize full compensation
(differential pressure, line pressure, and temperature measurement)
• Saturated steam: Utilize differential and line pressure, or differential
pressure and temperature measurement
3051S Scalable
MultiVariable Transmitter
• Liquids: Utilize differential pressure and temperature measurement
• Liquids at stable temperatures: Utilize differential pressure measurement
Additional Information
Specifications: page 68
Certifications: page 93
Dimensional Drawings: page 98
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter Type
3051SMV
Scalable MultiVariable Transmitter
Performance Class
Standard
3051SMV MultiVariable SuperModule, Measurement Types 1 and 2
3(1)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,10-year stability, 12-year limited warranty
5
Classic MV: 0.04% span DP accuracy, 100:1 rangedown, 5-year stability
3051SMV Single Variable SuperModule, Measurement Types 3 and 4
1(2)
Ultra: 0.025% span DP accuracy, 200:1 rangedown, 10-year stability, 12-year limited warranty
2
Classic: 0.055% span DP accuracy, 100:1 rangedown, 5-year stability
3(1)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,10-year stability, 12-year limited warranty
Standard
★
★
★
★
★
MultiVariable Type
Standard
M
P
MultiVariable Measurement with Fully Compensated Mass and Energy Flow
MultiVariable Measurement with Direct Process Variable Output
Standard
★
★
Measurement Type
Standard
1
2
3
4
Differential Pressure, Static Pressure, and Temperature
Differential Pressure and Static Pressure
Differential Pressure and Temperature
Differential Pressure
Standard
★
★
★
★
Differential Pressure Range
Standard
0(2)(3)
1
2
3
4(2)
5(2)
16
-3 to 3 inH2O (-7,47 to 7,47 mbar)
-25 to 25 inH2O (-62,2 to 62,2 mbar)
-250 to 250 inH2O (-623 to 623 mbar)
-1000 to 1000 inH2O (-2,5 to 2,5 bar)
-300 to 300 psi (-20,7 to 20,7 bar)
-2000 to 2000 psi (-137,9 to 137,9 bar)
Standard
★
★
★
★
★
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Static Pressure Type
Standard
N(4)
A
G
Standard
★
★
★
None
Absolute
Gage
Static Pressure Range
Absolute
Gage
Standard
N(4)
3
None
Range 3
0.5 to 800 psia (0,03 to 55,2 bar)
4(5)
Range 4
0.5 to 3626 psia (0,03 to 250 bar)
Standard
★
★
-14.2 to 800 psig
(-0,98 to 55,2 bar)
-14.2 to 3626 psig
(-0,98 to 250 bar)
★
Temperature Input
Standard
N(6)
R(7)
Standard
★
★
None
RTD Input (Type Pt 100, -328 to 1562 °F (-200 to 850 °C))
Isolating Diaphragm
Standard
2(8)
3(8)
Expanded
5(9)
7
Standard
★
★
316L SST
Alloy C-276
Tantalum
Gold-Plated 316L SST
Material Type
Process Connection
Standard
000
A11(10)
A12(10)
B11(10)(11)
B12(10)(11)
C11(10)
D11(10)
EA2(10)
EA3(10)
EA5(10)
E11
E12
E13(8)
E14
E15(8)
E16(8)
E21
E22
E23(8)
E24
E25(8)
E26(8)
Size
Flange
Material
Drain Vent
None
Assemble to Rosemount 305/306 Integral Manifold
Assemble to Rosemount 304 or AMF Manifold with SST Traditional Flange
Assemble to one Rosemount 1199 Seal
Assemble to two Rosemount 1199 Seals
Assemble to Rosemount 405 Primary Element
Assemble to Rosemount 1195 Integral Orifice and Rosemount 305 Integral Manifold
Assemble to Rosemount Annubar Primary Element with
SST
316 SST
Coplanar flange
Assemble to Rosemount Annubar Primary Element with
Cast C-276
Alloy C-276
Coplanar flange
Assemble to Rosemount Annubar Primary Element with
SST
Alloy C-276
Coplanar flange
1/4–18 NPT
Coplanar flange
Carbon Steel
316 SST
1
Coplanar flange
/4–18 NPT
SST
316 SST
1
Coplanar flange
/4–18 NPT
Cast C-276
Alloy C-276
1/4–18 NPT
Coplanar flange
Cast Alloy 400 Alloy 400/K-500
1
Coplanar flange
/4–18 NPT
SST
Alloy C-276
1
Coplanar flange
/4–18 NPT
Carbon Steel
Alloy C-276
Coplanar flange
RC 1/4
Carbon Steel
316 SST
Coplanar flange
RC 1/4
SST
316 SST
Coplanar flange
RC 1/4
Cast C-276
Alloy C-276
Coplanar flange
RC 1/4
Cast Alloy 400 Alloy 400/K-500
Coplanar flange
RC 1/4
SST
Alloy C-276
Coplanar flange
RC 1/4
Carbon Steel
Alloy C-276
Bolting
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
17
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
F12
F13(8)
F14
F15(8)
F22
F23(8)
F24
F25(8)
Traditional flange
Traditional flange
Traditional flange
Traditional flange
Traditional flange
Traditional flange
Traditional flange
Traditional flange
1/4–18
NPT
NPT
1
/4–18 NPT
1/4–18 NPT
RC 1/4
RC 1/4
RC 1/4
RC 1/4
SST
Cast C-276
Cast Alloy 400
SST
SST
Cast C-276
Cast Alloy 400
SST
316 SST
Alloy C-276
Alloy 400/K-500
Alloy C-276
316 SST
Alloy C-276
Alloy 400/K-500
Alloy C-276
F52
G11
G12
G14(8)
G15(8)
G21
G22
G31
Expanded
EB6
F32
F42
F62
F72
G41
DIN-compliant traditional flange
Vertical mount level flange
Vertical mount level flange
Vertical mount level flange
Vertical mount level flange
Vertical mount level flange
Vertical mount level flange
Vertical mount level flange
1/4–18
SST
SST
SST
Cast C-276
Cast C-276
SST
SST
SST
316 SST
1/4–18
NPT
2-in. ANSI class 150
2-in. ANSI class 300
2-in. ANSI class 150
2-in. ANSI class 300
3-in. ANSI class 150
3-in. ANSI class 300
DIN- DN 50 PN 40
Assemble to Primary Element with Manifold and Coplanar Flange, CS, Alloy C-276
1/4–18 NPT
Bottom vent traditional flange
SST
316 SST
Bottom vent traditional flange
RC 1/4
SST
316 SST
1
DIN-compliant traditional flange
/4–18 NPT
SST
316 SST
1/4–18 NPT
DIN-compliant traditional flange
SST
316 SST
Vertical mount level flange
DIN- DN 80 PN 40
SST
★
★
★
★
★
★
★
★
7/16-in.
bolting
★
★
★
★
★
★
★
★
M10 bolting
M12 bolting
Transmitter Output
Standard
A
Housing Style
Standard
1A
1B
1J
1K
Expanded
1C
1L
Standard
★
4–20 mA with digital signal based on HART protocol
Material
Conduit Entry Size
PlantWeb housing
PlantWeb housing
PlantWeb housing
PlantWeb housing
Aluminum
Aluminum
SST
SST
1/2–14
PlantWeb housing
PlantWeb housing
Aluminum
SST
G1/2
G1/2
NPT
M20 x 1.5
1/2–14 NPT
M20 x 1.5
Standard
★
★
★
★
Options (Include with selected model number)
RTD Cable (RTD Sensor must be ordered separately)
Standard
C12
RTD Input with 12 ft. (3.66 m) of Shielded Cable
C13
RTD Input with 24 ft. (7.32 m) of Shielded Cable
C14
RTD Input with 75 ft. (22.86 m) of Shielded Cable
C20(12)
RTD Input with 27 in. (69 cm) of Armored Shielded Cable
C21
RTD Input with 4 ft. (1.22 m) of Armored Shielded Cable
C22
RTD Input with 12 ft. (3.66 m) of Armored Shielded Cable
C23
RTD Input with 24 ft. (7.32 m) of Armored Shielded Cable
C24
RTD Input with 75 ft. (22.86 m) of Armored Shielded Cable
C30(12)
RTD Input with 25 in. (64 cm) of ATEX/IECEx Flameproof Cable
C32
RTD Input with 12 ft. (3.66 m) of ATEX/IECEx Flameproof Cable
C33
RTD Input with 24 ft. (7.32 m) of ATEX/IECEx Flameproof Cable
C34
RTD Input with 75 ft. (22.86 m) of ATEX/IECEx Flameproof Cable
C40(12)
RTD Input with 34 in. (86.36 cm) Shielded Cable and 24 in. (60.96 cm) FM Approved Coupling Flex
C41(12)
RTD Input with 40 in. (101.60 cm) Shielded Cable and 30 in. (76.20 cm) FM Approved Coupling Flex
18
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Mounting Brackets(13)
Standard
B4
Coplanar flange bracket, all SST, 2-in. pipe and panel
B1
Traditional flange bracket, Carbon Steel, 2-in. pipe
B2
Traditional flange bracket, Carbon Steel, panel
B3
Traditional flange flat bracket, Carbon Steel, 2-in. pipe
B7
Traditional flange bracket, B1 with SST bolts
B8
Traditional flange bracket, B2 with SST bolts
B9
Traditional flange bracket, B3 with SST bolts
BA
Traditional flange bracket, B1, all SST
BC
Traditional flange bracket, B3, all SST
Software Configuration
Standard
C1
Custom software configuration
Note: A Configuration Data Sheet must be completed, see document number 00806-0100-4803.
C2
Custom flow configuration
Note: A Custom Fluid Data Sheet must be completed, see document number 00806-0200-4803.
C4
NAMUR alarm and saturation levels, high alarm
C5
NAMUR alarm and saturation levels, low alarm
C6
Custom alarm and saturation signal levels, high alarm
C7
Custom alarm and saturation signal levels, low alarm
C8
Low alarm (standard Rosemount alarm and saturation levels)
Special Configuration
Standard
1
D2(13)
/2-14 NPT flange adapter
D4
External ground screw assembly
D5(13)
Delete transmitter drain/vent valves (install plugs)
Expanded
D9(13)
RC 1/2 SST flange adapter
(13)
D7
Coplanar flange without drain/vent ports
Product Certifications
Standard
E1
ATEX Flameproof
I1
ATEX Intrinsic Safety
N1
ATEX Type n
ND
ATEX Dust
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
E4
TIIS Flameproof
K4
TIIS Flameproof and Intrinsic Safety (combination E4 and I4)
E5
FM Explosion-proof, Dust Ignition-proof
I5
FM Intrinsically Safe, Division 2
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5 and I5)
E6(14)
CSA Explosion-proof, Dust Ignition-proof, Division 2
I6
CSA Intrinsically Safe
K6(14)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and I6)
E7
IECEx Flameproof, Dust Ignition-proof
I7
IECEx Intrinsic Safety
N7
IECEx Type n
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of E7, I7, and N7)
E2
INMETRO Flameproof
I2
INMETRO Intrinsic Safety
E3
China Flameproof
I3
China Intrinsic Safety
Standard
★
★
★
★
★
★
★
★
★
Standard
★
★
★
★
★
★
★
Standard
★
★
★
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
19
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
Table 3. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
KA(14)(15)
ATEX and CSA Explosion-proof, Intrinsically Safe, Division 2 (combination of E1, E6, I1, and I6)
KB(14)(15)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5, E6, I5, and I6)
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5, and I1)
KD(14)(15)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, E6, E1, I5, I6, and I1)
DW(16)
NSF Drinking Water Certification
Alternate Materials of Construction
Standard
L1
Inert sensor fill fluid (Differential and Gage sensors only) Note: Silicone fill fluid is standard.
L2
Graphite-filled PTFE O-ring
L4(13)
Austenitic 316 SST bolts
L5(8)(13)
ASTM A193, Grade B7M bolts
L6(13)
Alloy K-500 bolts
L7(8)(13)
ASTM A453, Class D, Grade 660 bolts
L8(13)
ASTM A193, Class 2, Grade B8M bolts
Digital Display
Standard
M5
PlantWeb LCD Display
Special Procedures
Standard
P1(17)
Hydrostatic testing with certificate
P9(2)
4500 psig (310 bar) static pressure limit
P0(2)(18)
6092 psig (420 bar) static pressure limit
Expanded
P2(13)
Cleaning for special services
P3(13)
Cleaning for less than 1PPM chlorine/fluorine
Special Certifications
Standard
Q4
Calibration Certificate
QP
Calibration Certificate and Tamper Evident Seal
Q8
Material Traceability Certification per EN 10204 3.1
Q16
Surface Finish Certification for Sanitary Remote Seals
QZ
Remote Seal System Performance Calculation Report
Transient Protection
Standard
T1
Transient terminal block
Conduit Electrical Connector
Standard
GE(19)
M12, 4-pin, Male Connector (eurofast®)
(19)
GM
A size Mini, 4-pin, Male Connector (minifast®)
Cold Temperature
Standard
BRR
-60 °F (-51 °C) Cold Temperature Start-up
Typical Model Number:
3051SMV 3 M 1 2 G 4 R 2 E12 A 1A B4 C2 M5
(1) Only available with DP range codes 2 and 3, 316L SST or Alloy C-276 isolating diaphragm and silicone fill fluid.
(2) Only available with Measurement Type codes 3 and 4.
(3) DP Range 0 is only available with traditional flange, 316L SST diaphragm material, and Bolting option L4.
(4) Required for Measurement Type codes 3 and 4.
(5) For Measurement Type 1 and 2 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are -14.2 to 2000 psig
(-0,98 to 137,9 bar).
(6) Required for Measurement Type codes 2 and 4.
(7) Required for Measurement Type codes 1 and 3. RTD Sensor must be ordered separately.
20
★
★
★
★
★
Standard
★
★
★
★
★
★
★
Standard
★
Standard
★
★
★
Standard
★
★
★
★
★
Standard
★
Standard
★
★
Standard
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
(8) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
(9) Tantalum diaphragm material is only available for DP ranges 2-5.
(10) “Assemble to” items are specified separately and require a completed model number.
(11) Consult an Emerson Process Management representative for performance specifications.
(12) For use with Flowmeters with integral RTDs.
(13) Not available with process connection option code A11.
(14) Not available with M20 or G ½ conduit entry size.
(15) RTD cable not available with this option.
(16) Requires 316L SST diaphragm material, glass-filled PTFE O-ring (standard), and Process Connection code E12 or F12.
(17) Not available with DP range 0.
(18) Requires 316L SST or Alloy C-276 diaphragm material, assemble to Rosemount 305 Integral Manifold or DIN-compliant traditional flange process
connection, and bolting option L8. Limited to differential pressure ranges 2-5.
(19) Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Non-Incendive approval (option code I5), install in accordance with Rosemount
drawing 03151-1009 to maintain outdoor rating (NEMA 4X and IP66).
21
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Rosemount 3051SF DP Flowmeters
Rosemount 3051SF Flowmeters integrate industry leading transmitters with
industry leading primary elements. Capabilities include:
3051SFC
3051SFA
3051SFP
•
Flowmeters are factory configured to meet your application needs
(Configuration Data Sheet required)
•
MultiVariable capabilities allow scalable flow compensation
(Measurement Types 1-7)
•
HART 4-20, Wireless, and FOUNDATION fieldbus protocols
•
Ultra for Flow for improved flow performance across wider flow ranges
•
Integral temperature measurement (Option Code T)
•
Advanced Diagnostics (Option Code DA2)
•
Direct or remote mount configurations available
Additional Information
Specifications: page 68
Dimensional Drawings: page 103
Rosemount 3051SFA Annubar Flowmeter
•
Annubar flowmeters reduce permanent pressure loss by creating less blockage in the pipe
•
Ideal for large line size installations when cost, size and weight of the flowmeter are concerns
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Measurement
Type
• = Available
—=
Unavailable
Model
Product Description
D
1-7
3051SFA
Annubar Flowmeter
•
•
—
•
Standard
★
—
—
—
—
—
—
•
•
•
•
•
•
•
—
★
★
★
★
★
★
★
•
•
•
•
•
•
Standard
★
★
★
Measurement Type
Standard
1
2
3
4
5
6
7
D
MultiVariable (Fully Compensated Mass & Energy Flow) – Differential & Static Pressures w/
Temperature
MultiVariable (Compensated Flow) – Differential & Static Pressures
MultiVariable (Compensated Flow) – Differential Pressure & Temperature
MultiVariable (Compensated Flow) – Differential Pressure
MultiVariable (Direct Measurement) – Differential & Static Pressures with Temperature
MultiVariable (Direct Measurement) – Differential & Static Pressures
MultiVariable (Direct Measurement) – Differential Pressure & Temperature
Differential Pressure
Fluid Type
Standard
L
G
S
22
Liquid
Gas
Steam
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Line Size
Standard
020
025
030
035
040
050
060
070
080
100
120
Expanded
140
160
180
200
240
300
360
420
480
600
720
780
840
900
960
D
1-7
2-in. (50 mm)
21/2-in. (63.5 mm)
3-in. (80 mm)
31/2-in. (89 mm)
4-in. (100 mm)
5-in. (125 mm)
6-in. (150 mm)
7-in. (175 mm)
8-in. (200 mm)
10-in. (250 mm)
12-in. (300 mm)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
14-in. (350 mm)
16-in. (400 mm)
18-in. (450 mm)
20-in. (500 mm)
24-in. (600 mm)
30-in. (750 mm)
36-in. (900 mm)
42-in. (1066 mm)
48-in. (1210 mm)
60-in. (1520 mm)
72-in. (1820 mm)
78-in. (1950 mm)
84-in. (2100 mm)
90-in. (2250 mm)
96-in. (2400 mm)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Range C from the Pipe I.D. table
Range D from the Pipe I.D. table
•
•
•
•
Range A from the Pipe I.D. table
Range B from the Pipe I.D. table
Range E from the Pipe I.D. table
Non-standard Pipe I.D. Range or Line Sizes greater than 12-in. (300 mm)
•
•
•
•
•
•
•
•
Carbon steel (A105)
316 Stainless Steel
No Mounting (Customer Supplied)
•
•
•
•
•
•
Chrome-Moly Grade F-11
Chrome-Moly Grade F-22
Chrome-Moly Grade F-91
•
•
•
•
•
•
•
•
•
•
•
•
Standard
★
★
★
★
★
★
★
★
★
★
★
Pipe I.D. Range
Standard
C
D
Expanded
A
B
E
Z
Standard
★
★
Pipe Material / Mounting Assembly Material
Standard
C
S
0(1)
Expanded
G
N
J
Standard
★
★
★
Piping Orientation
Standard
H
D
U
Horizontal Piping
Vertical Piping with Downwards Flow
Vertical Piping with Upwards Flow
Standard
★
★
★
23
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Annubar Type
Standard
P
F
Expanded
L
G
M
D
1-7
Pak-Lok
Flanged with opposite side support
•
•
•
•
Flange-Lok
Gear-Drive Flo-Tap
Manual Flo-Tap
•
•
•
•
•
•
316 Stainless Steel
•
•
Alloy C-276
•
•
Sensor size 1 — Line sizes 2-in. (50 mm) to 8-in. (200 mm)
Sensor size 2 — Line sizes 6-in. (150 mm) to 96-in. (2400 mm)
Sensor size 3 — Line sizes greater than 12-in. (300 mm)
•
•
•
•
•
•
Standard
★
★
★
Compression/Threaded Connection
150# RF ANSI
300# RF ANSI
600# RF ANSI
DN PN16 Flange
DN PN40 Flange
DN PN100 Flange
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Standard
★
★
★
★
★
★
★
900# RF ANSI
1500# RF ANSI
2500 # RF ANSI
150# RTJ Flange
300# RTJ Flange
600# RTJ Flange
900# RTJ Flange
1500# RTJ Flange
2500# RTJ Flange
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Standard
★
•
•
•
•
★
★
•
•
•
•
•
•
•
•
•
•
Standard
★
★
Sensor Material
Standard
S
Expanded
H
Standard
★
Sensor Size
Standard
1
2
3
Mounting Type
Standard
T1
A1
A3
A6
D1
D3
D6
Expanded
A9(2)
AF(2)
AT(2)
R1
R3
R6
R9(2)
RF(2)
RT(2)
Opposite Side Support or Packing Gland
Standard
0
C
D
Expanded
J
K
L
N
R
24
No opposite side support or packing gland (Required for Pak-Lok and Flange-Lok models)
Opposite Side Support – Required for Flanged Models
NPT Threaded Opposite Support Assembly – Extended Tip
Welded Opposite Support Assembly – Extended Tip
Packing Gland – Required for Flo-Tap Models
Packing Gland Material
Stainless Steel Packing Gland / Cage Nipple
Stainless Steel Packing Gland / Cage Nipple
Stainless Steel Packing Gland / Cage Nipple
Stainless Steel Packing Gland / Cage Nipple
Alloy C-276 Packing Gland / Cage Nipple
Rod Material
Carbon Steel
Stainless Steel
Carbon Steel
Stainless Steel
Stainless Steel
Packing Material
PTFE
PTFE
Graphite
Graphite
Graphite
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Isolation Valve for Flo-Tap Models
Standard
0(1)
Expanded
1
2
5
6
D
1-7
Not Applicable or Customer Supplied
•
•
Gate Valve, Carbon Steel
Gate Valve, Stainless Steel
Ball Valve, Carbon Steel
Ball Valve, Stainless Steel
•
•
•
•
•
•
•
•
Integral RTD – not available with Flanged model greater than class 600#
No Temperature Sensor
•
•
•
•
Remote Thermowell and RTD
•
•
Direct-mount, Integral 3-valve Manifold– not available with Flanged model greater than class 600
Direct -mount, 5-valve Manifold – not available with Flanged model greater than class 600
Remote-mount NPT Connections (1/2-in. FNPT)
•
•
•
•
•
•
Direct-mount, High Temperature 5-valve Manifold – not available with Flanged model greater
than class 600
Remote-mount SW Connections (1/2-in.)
•
•
•
•
•
•
•
•
•
•
Standard
★
★
★
•
—
—
—
—
•
•
•
•
•
Standard
★
★
★
★
★
•
•
•
•
—
—
Standard
★
★
★
•
•
•
•
•
•
•
•
—
•
•
•
•
—
—
—
Standard
★
★
★
★
★
★
★
★
Standard
★
Temperature Measurement
Standard
T(3)
0(4)
Expanded
R(3)
Standard
★
★
Transmitter Connection Platform
Standard
3
5
7
Expanded
6
8
Standard
★
★
★
Differential Pressure Range
Standard
1
2
3
0 to 25 in H2O (0 to 62.3 mbar)
0 to 250 in H2O (0 to 623 mbar)
0 to 1000 in H2O (0 to 2.5 bar)
Static Pressure Range
Standard
A(5)
D
E(6)
J
K(6)
None
Absolute 0 to 800 psia (0 to 55.2 bar)
Absolute 0 to 3626 psia (0 to 250 bar)
Gage -14.2 to 800 psig (-0.979 to 55.2 bar)
Gage -14.2 to 3626 psig (-0.979 to 250 bar)
Transmitter Output
Standard
A
F
X(7)
4–20 mA with digital signal based on HART protocol
FOUNDATION fieldbus protocol (requires PlantWeb housing)
Wireless (Requires wireless options and Wireless Plantweb housing)
Transmitter Housing Style
Standard
00
1A
1B
1J
1K
2A
2B
2E
None (Customer-supplied electrical connection)
PlantWeb Housing
PlantWeb Housing
PlantWeb Housing
PlantWeb Housing
Junction Box Housing
Junction Box Housing
Junction Box housing with output for remote display and
interface
Material
Aluminum
Aluminum
SST
SST
Aluminum
Aluminum
Aluminum
Conduit Entry
Size
1/2-14
NPT
M20 x 1.5
1/2-14 NPT
M20 x 1.5
1
/2-14 NPT
M20 x 1.5
1
/2-14 NPT
25
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
2F
2J
2M
5A(8)
5J(8)
7J(7)(9)
Expanded
1C
1L
2C
2G
Junction Box housing with output for remote display and
interface
Junction Box Housing
Junction Box housing with output for remote display and
interface
Wireless PlantWeb housing
Wireless PlantWeb housing
Quick Connect (A size Mini, 4-pin male termination)
Aluminum
M20 x 1.5
•
—
★
SST
SST
1
•
•
—
—
★
★
Aluminum
SST
1
1
•
•
•
—
—
—
★
★
★
PlantWeb Housing
PlantWeb Housing
Junction Box Housing
Junction Box housing with output for remote display and
interface
Aluminum
SST
Aluminum
Aluminum
G1/2
G1/2
G1/2
G1/2
•
•
•
•
•
•
—
—
D
1-7
/2-14 NPT
/2-14 NPT
1
/2-14 NPT
/2-14 NPT
Transmitter Performance Class
Standard
3051S MultiVariable SuperModule, Measurement Types 1, 2, 5, and 6
3
Ultra for Flow: 0.8% flow rate accuracy, 14:1 flow turndown, 10-year stability, limited 12-year
warranty
5
Classic MV: 1.15% flow rate accuracy, 8:1 flow turndown, 5-yr. stability
3051S Single Variable SuperModule, Measurement Types 3, 4, 7, and D
1
Ultra: up to 0.95% flow rate accuracy, 8:1 flow turndown, 10-year stability, limited 12-year
warranty
2
Classic: up to 1.4% flow rate accuracy, 8:1 flow turndown, 5-year stability
3(10)
Ultra for Flow: 0.8% flow rate accuracy, 14:1 flow turndown, 10-year stability, limited 12-year
warranty
Standard
•
•
★
—
•
★
•
—
★
•
•
—
•
★
★
•
—
Standard
★
•
—
★
•
•
—
—
★
★
•
—
•
—
•
•
•
•
•
•
•
•
•
•
Wireless Options (Requires option code X and wireless PlantWeb housing)
Update Rate, Operating Frequency and Protocol
Standard
WA
User Configurable Update Rate
Operating Frequency and Protocol
Standard
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Omnidirectional Wireless Antenna
Standard
WK
External Antenna
WM
Extended Range, External Antenna
Expanded
WN
High-Gain, Remote Antenna
SmartPower™
Standard
1(11)
Adapter for Black Power Module (I.S. Power Module Sold Separately)
Other Options (Include with selected model number)
Pressure Testing
Expanded
P1(12)
Hydrostatic Testing with Certificate
PX(12)
Extended Hydrostatic Testing
Special Cleaning
Expanded
P2
Cleaning for Special Services
PA
Cleaning per ASTM G93 level D (section 11.4)
Material Testing
Expanded
V1
Dye Penetrant Exam
26
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Material Examination
Expanded
V2
Radiographic Examination
Flow Calibration
Expanded
W1
Flow Calibration (Average K)
WZ
Special Calibration
Special Inspection
Standard
QC1
Visual & Dimensional Inspection with Certificate
QC7
Inspection & Performance Certificate
Surface Finish
Standard
RL
Surface finish for Low Pipe Reynolds Number in Gas & Steam
RH
Surface finish for High Pipe Reynolds Number in Liquid
Material Traceability Certification
Standard
Q8(13)
Material Traceability Certificate per EN 10204:2004 3.1
Code Conformance
Expanded
J2(14)
ANSI / ASME B31.1
J3(14)
ANSI / ASME B31.3
Material Conformance
Expanded
J5(15)
NACE MR-0175 / ISO 15156
Country Certification
Standard
J6
European Pressure Directive (PED)
Expanded
J1
Canadian Registration
Installed in Flanged Pipe Spool Section
Expanded
H3
150# Flanged Connection with Rosemount Standard Length and Schedule
H4
300# Flanged Connection with Rosemount Standard Length and Schedule
H5
600# Flanged Connection with Rosemount Standard Length and Schedule
Instrument Connections for Remote Mount Option
Standard
G2
Needle Valves, Stainless Steel
G6
OS&Y Gate Valve, Stainless Steel
Expanded
G1
Needle Valves, Carbon Steel
G3
Needle Valves, Alloy C-276
G5
OS&Y Gate Valve, Carbon Steel
G7
OS&Y Gate Valve, Alloy C-276
Special Shipment
Standard
Y1
Mounting Hardware Shipped Separately
Attach To
Expanded
H1
Attach to Transmitter
Special Dimensions
Expanded
VM
Variable Mounting
VT
Variable Tip
VS
Variable length Spool Section
D
1-7
•
•
•
•
•
•
•
•
•
•
Standard
★
★
•
•
•
•
Standard
★
★
•
•
Standard
★
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Standard
★
Standard
★
★
Standard
★
27
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Transmitter Calibration Certification
Standard
Q4
Calibration Certificate for Transmitter
QP
Calibration Certificate & Tamper Evident Seal
Quality Certification For Safety
Standard
QS(18)(24)
Prior-use Certificate of FMEDA data
QT(17)(18)(24)
Safety certified to IEC 61508 with certificate of FMEDA data
Product Certifications
Standard
E1
ATEX Flameproof
I1
ATEX Intrinsic Safety
IA
ATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol only
N1
ATEX Type n
ND
ATEX Dust
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
E4
TIIS Flameproof
E5
FM Explosion-proof, Dust Ignition-proof
I5
FM Intrinsically Safe, Division 2
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5 and I5)
E6(16)
CSA Explosion-proof, Dust Ignition-proof, Division 2
I6
CSA Intrinsically Safe
K6(16)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and I6)
E7
IECEx Flameproof, Dust Ignition-proof
I7
IECEx Intrinsic Safety
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7, I7, and N7)
E3
China Flameproof
I3
China Intrinsic Safety
KA(16)
ATEX and CSA Explosion-proof, Intrinsically Safe, Division 2 (combination of E1, I1, E6, and I6)
KB(16)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
(combination of E5, E6, I5, and I6)
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5, and I1)
KD(16)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, I5, E6, I6, E1, and I1)
Shipboard Approvals
Standard
SBS
American Bureau of Shipping
Sensor Fill Fluid and O-ring Options
Standard
L1
Inert Sensor Fill Fluid
L2
Graphite-Filled (PTFE) O-ring
LA
Inert Sensor Fill Fluid and Graphite-Filled (PTFE) O-ring
Digital Display(17)
Standard
M5
PlantWeb LCD display (Requires PlantWeb housing)
M7(18)(19)(20)
Remote mount LCD display and interface, PlantWeb housing, no cable; SST bracket
M8(18)(19)
Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15 m) cable; SST bracket
M9(18)(19)
Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31 m) cable; SST bracket
Transient Protection
Standard
T1(21)
Transient terminal block
Manifold for Remote Mount Option
Standard
F2
3-Valve Manifold, Stainless Steel
F6
5-Valve Manifold, Stainless Steel
28
Standard
★
★
•
•
•
•
D
1-7
•
•
—
—
Standard
★
★
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
—
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
•
•
•
•
★
★
•
•
Standard
★
•
•
•
•
•
•
Standard
★
★
★
•
•
•
•
•
•
•
•
Standard
★
★
★
★
•
•
Standard
★
•
•
•
•
Standard
★
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 4. Rosemount 3051SFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Expanded
F1
3-Valve Manifold, Carbon Steel
F3
3-Valve Manifold, Alloy C-276
F5
5-Valve Manifold, Carbon Steel
F7
5-Valve Manifold, Alloy C-276
PlantWeb Control Functionality
Standard
A01
FOUNDATION fieldbus Advanced Control Function Block Suite
PlantWeb Diagnostic Functionality
Standard
D01
FOUNDATION fieldbus Diagnostics Suite
DA2(22)
Advanced HART Diagnostic Suite
PlantWeb Enhanced Measurement Functionality
Standard
H01(23)
FOUNDATION fieldbus Fully Compensated Mass Flow Block
Cold Temperature
Standard
BRR
-60 °F (-51 °C) Cold Temperature Start-up
Alarm Limit(18)(24)
Standard
C4
NAMUR Alarm & Saturation Levels, High Alarm
C5
NAMUR Alarm & Saturation Levels, Low Alarm
C6
Custom Alarm & Saturation Levels, High Alarm
C7
Custom Alarm & Saturation Levels, Low Alarm
C8
Low Alarm (Standard Rosemount Alarm & Saturation Levels)
Hardware Adjustments and Ground Screw
Standard
D1(18)(24)(25)
Hardware Adjustments (zero, span, alarm, security)
D4
External Ground Screw Assembly
DA(18)(24)(25)
Hardware Adjustments (zero, span, alarm, security) & External Ground Screw Assembly
Conduit Plug
Standard
DO
316 SST Conduit Plug (standard for all 3051SF Models)
Conduit Electrical Connector
Standard
GE(26)
M12, 4-pin, Male Connector (eurofast®)
GM(26)
A size Mini, 4-pin, Male Connector (minifast®)
Typical Model Number: 3051SFA D L 060 D C H P S 2 T1 0 0 0 3 2A A 1A 3
•
•
•
•
•
•
•
•
D
1-7
•
—
Standard
★
•
•
—
—
Standard
★
★
•
—
Standard
★
—
•
Standard
★
•
•
•
•
•
•
•
•
•
•
Standard
★
★
★
★
★
•
•
•
—
•
—
Standard
★
★
★
•
•
Standard
★
•
•
•
•
Standard
★
★
(1) Provide the “A” dimension for Flanged, Flange-Lok, and Threaded Flo-Tap models. Provide the “B” dimension for Flange Flo-Tap models.
(2) Available in remote mount applications only.
(3) Temperature Measurement Option code T or R is required for Measurement Type codes 1, 3, 5, and 7.
(4) Required for Measurement Type codes 2, 4, 6, and D.
(5) Required for Measurement Type codes 3, 4, 7, and D.
(6) For Measurement Type 1, 2, 5, and 6 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are
-14.2 to 2000 psig (-0,98 to 137,9 bar).
(7) Available approvals are FM Intrinsically Safe, Division 2 (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1), and
IECEx Intrinsic Safety (option code I7).
(8) Only available with output code X.
(9) Available with output code A only.
(10) Only available with differential pressure ranges 2 and 3, and silicone fill fluid.
(11) Long-life Power Module must be shipped separately, order Part No. 00753-9220-0001.
(12) Applies to assembled flowmeter only, mounting not tested.
29
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
(13) Instrument Connections for Remote Mount Options and Isolation Valves for Flo-tap Models are not included in the Material Traceability Certification.
(14) Not available with Transmitter Connection Platform 6.
(15) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental
limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(16) Not available with M20 or G ½ conduit entry size.
(17) Not available with housing code 7J.
(18) Not available with output code X.
(19) Not available with output code F, option code DA2, or option code QT.
(20) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management representative for
additional information.
(21) Not available with Housing code 5A, 5J, or 7J. External ground screw assembly (option code D4) is included with the T1 option. The T1 option is not needed
with FISCO Product Certifications, transient protection is included with the FISCO Product Certification code IA.
(22) Includes Hardware Adjustments (option code D1) as standard. Not available with output code X.
(23) Requires Rosemount Engineering Assistant version 5.5.1 to configure.
(24) Not available with Output Protocol code F.
(25) Not available with housing style codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
(26) Not available with Housing code 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Division 2 (option code I5) or FM FISCO
Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009 to maintain outdoor rating (NEMA 4X and IP66).
30
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Rosemount 3051SFC Compact Orifice Flowmeter
•
Compact Conditioning flowmeters reduce straight piping requirements to 2D upstream and 2D
downstream from a flow disturbance
•
Simple installation of Compact flowmeters between any existing raised-face flanges
Table 5. Rosemount 3051SFC Compact Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Measurement
Type
• = Available
—=
Unavailable
Model
Product Description
D
1-7
3051SFC
Compact Orifice Flowmeter
•
•
—
•
Standard
★
—
—
—
—
—
—
•
•
•
•
•
•
•
—
★
★
★
★
★
★
★
Conditioning Orifice Plate
Orifice Plate
•
•
•
•
Standard
★
★
316 SST
•
•
Standard
★
1/2-in.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Standard
★
★
★
★
★
★
★
★
★
★
•
•
Standard
★
•
•
•
•
Standard
★
★
—
•
•
•
Standard
★
★
Transmitter Feature Board Measurement Type
Standard
1
2
3
4
5
6
7
D
MultiVariable (Fully Compensated Mass & Energy Flow) – Differential & Static Pressure w/
Temperature
MultiVariable (Compensated Flow) – Differential & Static Pressures
MultiVariable (Compensated Flow) – Differential Pressure & Temperature
MultiVariable (Compensated Flow) – Differential Pressure
MultiVariable (Direct Measurement) – Differential & Static Pressures with Temperature
MultiVariable (Direct Measurement) – Differential & Static Pressures
MultiVariable (Direct Measurement) – Differential Pressure & Temperature
Differential Pressure
Primary Element Technology
Standard
C
P
Material Type
Standard
S
Line Size
Standard
005(1)
010(1)
015(1)
020
030
040
060
080
100
120
(15 mm)
1-in. (25 mm)
11/2-in. (40 mm)
2-in. (50 mm)
3-in. (80 mm)
4-in. (100 mm)
6-in. (150 mm)
8-in. (200 mm)
10-in. (250 mm)
12-in. (300 mm)
Primary Element Style
Standard
N
Square Edged
Primary Element Type
Standard
040
065(2)
0.40 Beta Ratio ()
0.65 Beta Ratio ()
Temperature Measurement
Standard
T(4)
0(3)
Integral RTD
No Temperature Sensor
31
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 5. Rosemount 3051SFC Compact Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Expanded
R(4)
•
•
Transmitter Connection Platform
Remote Thermowell and RTD
D
1-7
Standard
3
7
•
•
•
•
Standard
★
★
•
•
•
•
•
•
Standard
★
★
★
•
—
—
—
—
•
•
•
•
•
Standard
★
★
★
★
★
•
•
•
•
—
—
Standard
★
★
★
—
•
•
•
•
—
—
—
Standard
★
★
★
★
★
★
★
★
Direct-mount, 3-valve Integral Manifold, SST
Remote-mount, 1/4-in. NPT Connections
Differential Pressure Range
Standard
1
2
3
0 to 25 inH2O (0 to 62.3 mbar)
0 to 250 inH2O (0 to 623 mbar)
0 to 1000 inH2O (0 to 2.5 bar)
Static Pressure Range
Standard
A(5)
D
E(6)
J
K(6)
None
Absolute 0 to 800 psia (0 to 55.2 bar)
Absolute 0 to 3626 psia (0 to 250 bar)
Gage -14.2 to 800 psig (-0.979 to 55.2 bar)
Gage -14.2 to 3626 psig (-0.979 to 250 bar)
Transmitter Output
Standard
A
F(7)
X(8)(9)
4–20 mA with digital signal based on HART protocol
FOUNDATION fieldbus protocol
Wireless
Transmitter Housing Style
Standard
00
1A
1B
1J
1K
2A
2B
2E
2F
2J
2M
5A(10)
5J(10)
7J(8)(11)
Expanded
1C
1L
2C
2G
None (Customer-supplied electrical connection)
PlantWeb Housing
PlantWeb Housing
PlantWeb Housing
PlantWeb Housing
Junction Box Housing
Junction Box Housing
Junction Box housing with output for remote display and
interface
Junction Box housing with output for remote display and
interface
Junction Box Housing
Junction Box housing with output for remote display and
interface
Wireless PlantWeb housing
Wireless PlantWeb housing
Quick Connect (A size Mini, 4-pin male termination)
PlantWeb Housing
PlantWeb Housing
Junction Box Housing
Junction Box housing with output for remote display and
interface
Material
Conduit Entry
Size
Aluminum
Aluminum
SST
SST
Aluminum
Aluminum
Aluminum
1/2-14
NPT
M20 x 1.5
1/2-14 NPT
M20 x 1.5
1
/2-14 NPT
M20 x 1.5
1
/2-14 NPT
•
•
•
•
•
•
•
•
Aluminum
M20 x 1.5
•
—
★
SST
SST
1
•
•
—
—
★
★
Aluminum
SST
1
1
•
•
•
—
—
—
★
★
★
Aluminum
SST
Aluminum
Aluminum
G1/2
G1/2
G1/2
G1/2
•
•
•
•
•
•
—
—
•
•
•
•
★
—
•
★
/2-14 NPT
/2-14 NPT
1
/2-14 NPT
/2-14 NPT
Transmitter Performance Class
Standard
3051S MultiVariable SuperModule, Measurement Types 1, 2, 5, and 6
3
Ultra for Flow: 0.75% flow rate accuracy, 14:1 flow turndown, 10-yr stability, limited 12-yr
warranty
5
Classic MV: 1.10% flow rate accuracy, 8:1 flow turndown, 5-yr stability
32
Standard
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 5. Rosemount 3051SFC Compact Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
3051S Single Variable SuperModule, Measurement Types 3, 4, 7, and D
1
Ultra: 0.90% flow rate accuracy, 8:1 flow turndown, 10-yr stability, limited 12-yr warranty
2
Classic: 1.40% flow rate accuracy, 8:1 flow turndown, 5-yr stability
3(12)
Ultra for Flow: 0.75% flow rate accuracy, 14:1 flow turndown, 10-yr stability, limited 12-yr
warranty
•
•
•
•
•
—
—
•
★
★
★
•
—
Standard
★
•
—
★
•
•
—
—
★
★
•
—
•
—
★
•
•
•
•
•
•
•
•
•
•
•
•
Standard
★
★
★
★
★
★
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Wireless Options (Requires option code X and wireless PlantWeb housing)
Update Rate, Operating Frequency, and Protocol
Standard
WA
User Configurable Update Rate
Operating Frequency and Protocol
Standard
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Omnidirectional Wireless Antenna
Standard
WK
External Antenna
WM
Extended Range, External Antenna
Expanded
WN
High-Gain, Remote Antenna
SmartPower™
Standard
1(13)
Adapter for Black Power Module (I.S. Power Module Sold Separately)
Other Options (Include with selected model number)
Installation Accessories
Standard
A
ANSI Alignment Ring (150#) (Only required for 10-in. (250 mm) and 12-in. (300mm) line sizes)
C
ANSI Alignment Ring (300#) (Only required for 10-in. (250 mm) and 12-in. (300mm) line sizes)
D
ANSI Alignment Ring (600#) (Only required for 10-in. (250 mm) and 12-in. (300mm) line sizes)
G
DIN Alignment Ring (PN 16)
H
DIN Alignment Ring (PN 40)
J
DIN Alignment Ring (PN 100)
Expanded
B
JIS Alignment Ring (10K)
R
JIS Alignment Ring (20K)
S
JIS Alignment Ring (40K)
Remote Adapters
Standard
E
Flange adapters 316 SST (1/2-in. NPT)
High Temperature Applications
Expanded
T
Graphite Valve Packing (Tmax = 850 °F)
Flow Calibration
Expanded
WC
Discharge Coefficient Verification (3 point)
WD
Discharge Coefficient Verification (full 10 point)
Pressure Testing
Expanded
P1
Hydrostatic Testing with Certificate
Special Cleaning
Expanded
P2
Cleaning for Special Processes
PA
Cleaning per ASTM G93 Level D (section 11.4)
Standard
★
33
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
Table 5. Rosemount 3051SFC Compact Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Special Inspection
Standard
QC1
Visual & Dimensional Inspection with Certificate
QC7
Inspection & Performance Certificate
Transmitter Calibration Certification
Standard
Q4
Calibration Data Certificate for Transmitter
QP
Calibration Certificate and Tamper Evident Seal
Quality Certification for Safety
Standard
QS(14)(15)
Prior-use certificate of FMEDA data
QT(14)(15)(18)
Safety Certified to IEC 61508 with certificate of FMEDA data
Material Traceability Certifications
Standard
Q8
Material Traceability Certification per EN 10204:2004 3.1
Code Conformance
Expanded
J2
ANSI / ASME B31.1
J3
ANSI / ASME B31.3
J4
ANSI / ASME B31.8
Material Conformance
Expanded
J5(16)
NACE MR-0175 / ISO 15156
Country Certification
Expanded
J1
Canadian Registration
Product Certifications
Standard
E1
ATEX Flameproof
I1
ATEX Intrinsic Safety
IA
ATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol only
N1
ATEX Type n
ND
ATEX Dust
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
E4
TIIS Flameproof
E5
FM Explosion-proof, Dust Ignition-proof
I5
FM Intrinsically Safe, Division 2
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5 and I5)
E6(17)
CSA Explosion-proof, Dust Ignition-proof, Division 2
I6
CSA Intrinsically Safe
K6(17)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and I6)
E7
IECEx Flameproof, Dust Ignition-proof
I7
IECEx Intrinsic Safety
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7, I7, and N7)
E3
China Flameproof
I3
China Intrinsic Safety
KA(17)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2 (combination of E1, I1, E6, and I6)
KB(17)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of
E5, E6, I5, and I6)
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5, and I1)
KD(17)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, E6, E1, I5, I6, and I1)
34
•
•
•
•
Standard
★
★
•
•
•
•
Standard
★
★
D
1-7
•
•
—
—
Standard
★
★
•
•
Standard
★
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
—
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
•
•
•
•
★
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 5. Rosemount 3051SFC Compact Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Shipboard Approvals
Standard
SBS
American Bureau of Shipping
Sensor Fill Fluid and O-ring Options
Standard
L1
Inert Sensor Fill Fluid
L2
Graphite-filled (PTFE) O-ring
LA
Inert sensor fill fluid and graphite-filled (PTFE) O-ring
Digital Display(18)
Standard
M5
PlantWeb LCD display
M7(15)(19)(20)
Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracket
M8(15)(19)
Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15m) cable, SST bracket
M9(15)(19)
Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31m) cable, SST bracket
Transient Protection
Standard
T1(21)
Transient terminal block
Manifold for Remote Mount Option
Standard
F2
3-Valve Manifold, SST
F6
5-Valve Manifold, SST
PlantWeb Control Functionality
Standard
A01
FOUNDATION fieldbus Advanced Control Function Block Suite
PlantWeb Diagnostic Functionality
Standard
D01
FOUNDATION fieldbus Diagnostics Suite
DA2(22)
Advanced HART Diagnostic Suite
PlantWeb Enhanced Measurement Functionality
Standard
H01(23)
FOUNDATION fieldbus Fully Compensated Mass Flow Block
Cold Temperature
Standard
BRR
-60 °F (-51 °C) Cold Temperature Start-up
Alarm Limit(14)(15)
Standard
C4
NAMUR Alarm & Saturation Levels, High Alarm
C5
NAMUR Alarm & Saturation Levels, Low Alarm
C6
Custom Alarm & Saturation Levels, High Alarm
C7
Custom Alarm & Saturation Levels, Low Alarm
C8
Low Alarm (Standard Rosemount Alarm & Saturation Levels)
Hardware Adjustments and Ground Screw
Standard
D1(14)(15)(24)
Hardware Adjustments (zero, span, alarm, security).
D4
External ground screw assembly
DA(14)(15)(24)
Hardware adjustments (zero, span, alarm, security) and external ground screw assembly
Conduit Plug
Standard
DO
316 SST Conduit Plug
Conduit Electrical Connector
Standard
ZE(25)
M12, 4-pin, Male Connector (eurofast)
ZM(25)
A size Mini, 4-pin, Male Connector (minifast)
Typical Model Number: 3051SFC 1 C S 060 N 065 T 3 2 J A 1A 3
★
•
•
D
1-7
•
•
•
•
•
•
Standard
★
★
★
•
•
•
•
•
•
•
•
Standard
★
★
★
★
•
•
Standard
★
•
•
•
•
Standard
★
★
•
—
Standard
★
•
•
—
—
Standard
★
★
•
—
Standard
★
•
•
Standard
★
•
•
•
•
•
•
•
•
•
•
Standard
★
★
★
★
★
•
•
•
—
•
—
Standard
★
★
★
•
•
Standard
★
•
•
•
•
Standard
★
★
35
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
(1) Not available for Primary Element Technology code C.
(2) For 2-in. (50 mm) line sizes the Primary Element Type is 0.6 for Primary Element Technology Code C.
(3) Required for Measurement Type codes 2, 4, 6, and D.
(4) Only available with Transmitter Feature Board Measurement Type: 1, 3, 5, 7.
(5) Required for Measurement Type codes 3, 4, 7, and D.
(6) For Measurement Type 1, 2, 5, and 6 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are
-14.2 to 2000 psig (-0,98 to 137,9 bar).
(7) Requires PlantWeb housing.
(8) Available approvals are FM Intrinsically Safe, Division 2 (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety
(option code I1), and IECEx Intrinsic Safety (option code I7).
(9) Requires wireless options and wireless PlantWeb housing.
(10) Only available with output code X.
(11) Available with output code A only.
(12) Only available with differential pressure ranges 2 and 3, and silicone fill fluid.
(13) Long-life Power Module must be shipped separately, order Part No. 00753-9220-0001.
(14) Not available with Output Protocol code F.
(15) Not available with output code X.
(16) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits
apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(17) Not available with M20 or G ½ conduit entry size.
(18) Not available with housing code 7J.
(19) Not available with output code F, option code DA2, or option code QT.
(20) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management representative
for additional information.
(21) Not available with Housing code 00, 5A, 5J, or 7J. External ground screw assembly (option code D4) is included with the T1 option. The T1 option is not needed
with FISCO Product Certifications, transient protection is included with the FISCO Product Certification code IA.
(22) Includes Hardware Adjustments (option code D1) as standard. Not available with output code X.
(23) Requires Rosemount Engineering Assistant version 5.5.1 to configure.
(24) Not available with housing style codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
(25) Not available with Housing code 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Division 2 (option code I5) or FM
FISCO Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009 to maintain outdoor rating (NEMA 4X and IP66).
36
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Rosemount 3051SFP Integral Orifice Flowmeter
•
Precision honed pipe section for increased accuracy in small line sizes
•
Self-centering plate design prevents alignment errors that magnify measurement inaccuracies
in small line sizes
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Measurement
Type
• = Available
— = Unavailable
Model
Product Description
D
1-7
3051SFP
Integral Orifice Flowmeter
•
•
—
•
Standard
★
—
—
—
—
—
—
•
•
•
•
•
•
•
—
★
★
★
★
★
★
★
316 SST
•
•
Standard
★
1/2-in.
•
•
•
•
•
•
Standard
★
★
★
NPT Female Body (Not Available with Remote Thermowell and RTD)
Socket Weld Body (Not Available with Remote Thermowell and RTD)
Pipe Ends: NPT threaded
Pipe Ends: Beveled
Pipe Ends: Flanged, DIN PN16, slip-on
Pipe Ends: Flanged, DIN PN40, slip-on
Pipe Ends: Flanged, DIN PN100, slip-on
Pipe Ends: Flanged, ANSI Class 150, weld-neck
Pipe Ends: Flanged, ANSI Class 300, weld-neck
Pipe Ends: Flanged, ANSI Class 600, weld-neck
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Standard
★
★
★
★
★
★
★
★
★
★
Pipe Ends: Flanged, RF, ANSI Class 150, slip-on
Pipe Ends: Flanged, RF, ANSI Class 300, slip-on
Pipe Ends: Flanged, RF, ANSI Class 600, slip-on
Pipe Ends: Flanged, RTJ, ANSI Class 150, slip-on
Pipe Ends: Flanged, RTJ, ANSI Class 300, slip-on
Pipe Ends: Flanged, RTJ, ANSI Class 600, slip-on
Special Process Connection
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Measurement Type
Standard
1
2
3
4
5
6
7
D
MultiVariable (Fully Compensated Mass & Energy Flow) – Differential & Static Pressures w/
Temperature
MultiVariable (Compensated Flow) – Differential and Static Pressures
MultiVariable (Compensated Flow) – Differential Pressure and Temperature
MultiVariable (Compensated Flow) – Differential Pressure
MultiVariable (Direct Measurement) – Differential and Static Pressures with Temperature
MultiVariable (Direct Measurement) – Differential and Static Pressures
MultiVariable (Direct Measurement) – Differential Pressure and Temperature
Differential Pressure
Body Material
Standard
S
Line Size
Standard
005
010
015
(15 mm)
1-in. (25 mm)
11/2-in. (40 mm)
Process Connection
Standard
T1
S1(1)
P1
P2
D1
D2
D3
W1
W3
W6
Expanded
A1
A3
A6
R1
R3
R6
P9
Orifice Plate Material
Standard
S
316 SST
Standard
★
37
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Expanded
H
M
Alloy C-276
Alloy 400
•
•
•
•
D
1-7
0.066-in. (1.68 mm) for 1/2-in. pipe
0.109-in. (2.77 mm) for 1/2-in. pipe
0.160-in. (4.06 mm) for 1/2-in. pipe
0.196-in. (4.98 mm) for 1/2-in. pipe
0.260-in. (6.60 mm) for 1/2-in. pipe
0.340-in. (8.64 mm) for 1/2-in. pipe
0.150-in. (3.81 mm) for 1-in. pipe
0.250-in. (6.35 mm) for 1-in. pipe
0.345-in. (8.76 mm) for 1-in. pipe
0.500-in. (12.70 mm) for 1-in. pipe
0.630-in. (16.00 mm) for 1-in. pipe
0.800-in. (20.32 mm) for 1-in. pipe
0.295-in. (7.49 mm) for 11/2-in. pipe
0.376-in. (9.55 mm) for 11/2-in. pipe
0.512-in. (13.00 mm) for 11/2-in. pipe
0.748-in. (19.00 mm) for 11/2-in. pipe
1.022-in. (25.96 mm) for 11/2-in. pipe
1.184-in. (30.07 mm) for 11/2-in. pipe
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.010-in. (0.25 mm) for 1/2-in. pipe
0.014-in. (0.36 mm) for 1/2-in. pipe
0.020-in. (0.51 mm) for 1/2-in. pipe
0.034-in. (0.86 mm) for 1/2-in. pipe
•
•
•
•
•
•
•
•
Direct-mount, 3-valve Manifold, SST
Direct-mount, 5-valve Manifold, SST
Remote-mount, 3-valve Manifold, SST
Remote-mount, 5-valve Manifold, SST
•
•
•
•
•
•
•
•
Direct-mount, 3-valve Manifold, Alloy C-276
Direct-mount, 5-valve Manifold, Alloy C-276
Direct-mount, High Temperature, 5-valve Manifold, SST
Remote-mount, 3-valve Manifold, Alloy C-276
Remote-mount, 5-valve Manifold, Alloy C-276
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Standard
★
★
★
•
—
—
—
—
•
•
•
•
•
Standard
★
★
★
★
★
Bore Size Option
Standard
0066
0109
0160
0196
0260
0340
0150
0250
0345
0500
0630
0800
0295
0376
0512
0748
1022
1184
Expanded
0010
0014
0020
0034
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
Transmitter Connection Platform
Standard
D3
D5
R3
R5
Expanded
D4
D6
D7
R4
R6
Standard
★
★
★
★
Differential Pressure Range
Standard
1
2
3
0 to 25 inH2O (0 to 62.3 mbar)
0 to 250 inH2O (0 to 623 mbar)
0 to 1000 inH2O (0 to 2.5 bar)
Static Pressure Range
Standard
A(2)
D
E(3)
J
K(3)
38
None
Absolute 0 to 800 psia (0 to 55.2 bar)
Absolute 0 to 3626 psia (0 to 250 bar)
Gage -14.2 to 800 psig (-0.979 to 55.2 bar)
Gage -14.2 to 3626 psig (-0.979 to 250 bar)
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Transmitter Output
D
1-7
Standard
A
F
X(4)
•
•
•
•
—
—
Standard
★
★
★
NPT
M20 x 1.5
1
/2-14 NPT
M20 x 1.5
1/2-14 NPT
M20 x 1.5
1/2-14 NPT
•
•
•
•
•
•
•
•
—
•
•
•
•
—
—
—
Standard
★
★
★
★
★
★
★
★
M20 x 1.5
•
—
★
1/2-14
•
•
—
—
★
★
•
•
•
—
—
—
★
★
★
•
•
•
•
•
•
—
—
4–20 mA with digital signal based on HART protocol
FOUNDATION fieldbus (Requires PlantWeb housing)
Wireless (Requires wireless options and wireless PlantWeb housing)
Transmitter Housing Style
Standard
00
1A
1B
1J
1K
2A
2B
2E
2F
2J
2M
5A(5)
5J(5)
7J(4)(6)
Expanded
1C
1L
2C
2G
Material
None (Customer-supplied electrical connection)
PlantWeb Housing
Aluminum
PlantWeb Housing
Aluminum
PlantWeb Housing
SST
PlantWeb Housing
SST
Junction Box Housing
Aluminum
Junction Box Housing
Aluminum
Junction Box Housing with output for remote
Aluminum
display and interface
Junction Box Housing with output for remote
Aluminum
display and interface
Junction Box Housing
SST
Junction Box Housing with output for remote
SST
display and interface
Wireless PlantWeb Housing
Aluminum
Wireless PlantWeb Housing
SST
Quick Connect (A size Mini, 4-pin male termination)
PlantWeb Housing
PlantWeb Housing
Junction Box Housing
Junction Box Housing with output for remote
display and interface
Aluminum
SST
Aluminum
Aluminum
Conduit Entry Size
1/2-14
NPT
/2-14 NPT
1
1
/2–14
1/2–14
NPT
NPT
G1/2
G1/2
G1/2
G1/2
Transmitter Performance Class
Standard
3051S MultiVariable SuperModule, Measurement Types 1, 2, 5, and 6
3(7)
Ultra for Flow: 0.95% flow rate accuracy, 14:1 flow turndown, 10-year stability, limited 12-year
warranty
5
Classic MV: 1.25% flow rate accuracy, 8:1 flow turndown, 5-year stability
3051S Single Variable SuperModule, Measurement Types 3, 4, 7, and D
1
Ultra: 1.05% flow rate accuracy, 8:1 flow turndown, 10-year stability, limited 12-year warranty
2
Classic: 1.50% flow rate accuracy, 8:1 flow turndown, 5-year stability
3(7)
Ultra for Flow: 0.95% flow rate accuracy, 14:1 flow turndown, 10-year stability, limited 12-year
warranty
Standard
•
•
★
—
•
★
•
•
•
•
•
•
★
★
★
•
—
Standard
★
•
—
★
•
•
—
—
★
★
Wireless Options (Requires option code X and wireless PlantWeb housing)
Update Rate, Operating Frequency and Protocol
Standard
WA
User Configurable Update Rate
Operating Frequency and Protocol
Standard
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Omnidirectional Wireless Antenna
Standard
WK
External Antenna
WM
Extended Range, External Antenna
39
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Expanded
WN
SmartPower™
Standard
1(8)
High-Gain, Remote Antenna
•
—
Adapter for Black Power Module (I.S. Power Module Sold Separately)
•
—
D
1-7
•
•
•
•
Standard
★
•
•
Standard
★
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Standard
★
★
•
•
Standard
★
•
•
•
•
•
•
•
•
•
•
•
•
★
Other Options (Include with selected model number)
Transmitter / Body Bolt Material
Expanded
G(9)
High temperature Option (850 °F (454 °C))
Temperature Sensor
Standard
T(10)
Thermowell and RTD
Optional Connection
Standard
G1
DIN 19213 Transmitter Connection
Pressure Testing
Expanded
P1(11)
Hydrostatic Testing with Certificate
Special Cleaning
Expanded
P2
Cleaning for Special Services
PA
Cleaning per ASTM G93 Level D (Section 11.4)
Material Testing
Expanded
V1
Dye Penetrant Exam
Material Examination
Expanded
V2
Radiographic Examination (available only with Process Connection code W1, W3, and W6)
Flow Calibration
Expanded
WD(12)
Discharge Coefficient Verification
WZ(12)
Special Calibration
Special Inspection
Standard
QC1
Visual & Dimensional Inspection with Certificate
QC7
Inspection & Performance Certificate
Material Traceability Certification
Standard
Q8
Material certification per EN 10204:2004 3.1
Code Conformance
Expanded
J2(13)
ANSI / ASME B31.1
J3(13)
ANSI / ASME B31.3
J4(13)
ANSI / ASME B31.8
Materials Conformance
Expanded
J5(14)
NACE MR-0175 / ISO 15156
Country Certification
Standard
J6
European Pressure Directive (PED)
Expanded
J1
Canadian Registration
40
Standard
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Transmitter Calibration Certification
Standard
Q4
Calibration Data Certificate for Transmitter
Quality Certification for Safety
Standard
QS(15)(16)
Prior-use Certificate of FMEDA data
QT(15)(16)(18)
Safety-certified to IEC 61508 with Certificate of FMEDA data
Product Certifications
Standard
E1
I1
IA
N1
ND
K1
E4
E5
I5
K5
E6(17)
I6
K6(17)
E7
I7
K7
E3
I3
KA(17)
KB(17)
ATEX Flameproof
ATEX Intrinsic Safety
ATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol only
ATEX Type n
ATEX Dust
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E1, I1, N1, and ND)
TIIS Flameproof
FM Explosion-proof, Dust Ignition-proof
FM Intrinsically Safe, Division 2
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E5 and I5)
CSA Explosion-proof, Dust Ignition-proof, Division 2
CSA Intrinsically Safe
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of E6 and I6)
IECEx Flameproof, Dust Ignition-proof
IECEx Intrinsic Safety
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n (combination of E7, I7, and N7)
China Flameproof
China Intrinsic Safety
ATEX and CSA Flameproof, Intrinsically Safe, Division 2 (combination of E1, I1, E6, and I6)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2 (combination of
E5, E6, I5, and I6)
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E1, I5, and I1)
KD(17)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, I5, E6, I6, E1, and I1)
Shipboard Approvals
Standard
SBS
American Bureau of Shipping
Sensor Fill Fluid and O-ring Options
Standard
L1
Inert Sensor Fill Fluid
L2
Graphite-filled (PTFE) O-ring
LA
Inert sensor fill fluid and graphite-filled (PTFE) O-ring
Digital Display(18)
Standard
M5
PlantWeb LCD display (Requires PlantWeb housing)
M7(15)(19)(20)
Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracket
M8(15)(20)
Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15 m) cable, SST bracket
M9(15)(20)
Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31 m) cable, SST bracket
Transient Protection
Standard
T1(21)
Transient terminal block
PlantWeb Control Functionality
Standard
A01
FOUNDATION fieldbus Advanced Control Function Block Suite
•
•
Standard
★
•
•
—
—
Standard
★
★
D
1-7
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
—
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
•
•
•
•
★
★
•
•
Standard
★
•
•
•
•
•
•
Standard
★
★
★
•
•
•
•
•
—
—
—
Standard
★
★
★
★
•
•
Standard
★
•
—
Standard
★
41
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 6. Rosemount 3051SFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
PlantWeb Diagnostic Functionality
Standard
D01
FOUNDATION fieldbus Diagnostics Suite
DA2(22)
Advanced HART Diagnostics Suite
PlantWeb Enhanced Measurement Functionality
Standard
H01(23)
FOUNDATION fieldbus Fully Compensated Mass Flow Block
Cold Temperature
Standard
BRR
-60 °F (-51 °C) Cold Temperature Start-up
Alarm Limit(15)(16)
Standard
C4
NAMUR Alarm & Saturation Levels, High Alarm
C5
NAMUR Alarm & Saturation Levels, Low Alarm
C6
Custom Alarm & Saturation Levels, High Alarm
C7
Custom Alarm & Saturation Levels, Low Alarm
C8
Low Alarm (Standard Rosemount Alarm & Saturation Levels)
Hardware Adjustments and Ground Screw
Standard
D1(15)(16)(24)
Hardware Adjustments (zero, span, alarm, security)
D4
External ground screw assembly
DA(15)(16)(24)
Hardware adjustments (zero, span, alarm, security) & External Ground Screw Assembly
Conduit Plug
DO
316 SST Conduit Plug
Conduit Electrical Connector
Expanded
GE (25)
M12, 4-pin, Male Connector (eurofast®)
GM(25)
A size Mini, 4-pin, Male Connector (minifast®)
Typical Model Number:
3051SFP
1
S
010
W3
S
0150
D3
1
J
A
1A
3
•
•
—
—
Standard
★
★
•
—
Standard
★
—
•
Standard
★
D
1-7
•
•
•
•
•
•
•
•
•
•
Standard
★
★
★
★
★
•
•
•
—
•
—
Standard
★
★
★
•
•
•
•
M5
(1) To improve pipe perpendicularity for gasket sealing, socket diameter is smaller than standard pipe O.D.
(2) Required for Measurement Type codes 3, 4, 7, and D.
(3) For Measurement Type 1, 2, 5, and 6 with DP range 1, absolute limits are 0.5 to 2000 psi (0,03 to 137,9 bar) and gage limits are
-14.2 to 2000 psig (-0,98 to 137,9 bar).
(4) Available approvals are FM Intrinsically Safe, Division 2 (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety
(option code I1), and IECEx Intrinsic Safety (option code I7).
(5) Only available with output code X.
(6) Only available with output code A.
(7) Only available with differential pressure ranges 2 and 3, and silicone fill fluid.
(8) Long-life Power Module must be shipped separately, order Part No. 00753-9220-0001.
(9) Not available with 11/2-in. (38 mm) line size.
(10) Thermowell material is the same as the body material.
(11) Does not apply to Process Connection codes T1 and S1.
(12) Not available for bore sizes 0010, 0014, 0020, or 0034.
(13) Not available with DIN Process Connection codes D1, D2, or D3.
(14) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply
to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(15) Not available with output code X.
(16) Not available with Output Protocol code F.
(17) Not available with M20 or G ½ conduit entry size.
(18) Not available with housing code 7J.
42
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
(19) See the 3051S Reference Manual (document number 00809-0100-4801) for cable requirements. Contact an Emerson Process Management representative for
additional information.
(20) Not available with output code F, option code DA2, or option code QT.
(21) Not available with Housing code 5A, 5J, or 7J. The T1 option is not needed with FISCO Product Certifications, transient protection is included with the FISCO
Product Certification code IA.
(22) Includes Hardware Adjustments (option code D1) as standard. Not available with output code X.
(23) Requires Rosemount Engineering Assistant version 5.5.1 to configure.
(24) Not available with housing style codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
(25) Not available with Housing code 5A, 5J, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Division 2 (option code I5) or
FM FISCO Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009 to maintain outdoor rating (NEMA 4X and IP66).
43
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Rosemount 3051S Electronic Remote Sensors
The 3051S ERS™ System is a flexible, 2-wire 4-20 mA HART
architecture that calculates differential pressure (DP) electronically
using two pressure sensors that are linked together with a
non-proprietary electrical wire.
Ideal applications for the 3051S ERS System include tall vessels and
distillation columns that have traditionally required long lengths of
capillary or impulse piping. When used in these types of applications,
the 3051S ERS System can deliver:
1
Secondary
3051SAM
•
More accurate and repeatable DP measurements
•
Faster time response
•
Simplified installations
•
Reduced maintenance
How to Order
Coplanar
In-Line
1. Choose two ERS transmitter models. These may be any
combination of 3051SAM and 3051SAL models.
2
3051SAL
Primary
Coplanar
3
In-Line
3051SAL1PG4AA1A1020DFF71DA00M5
3051SAM1ST2A2E11A2A
2. Decide which model will be the ERS Primary (4-20 mA loop
termination and optional LCD) and which will be the ERS
Secondary. This will be specified by the “Configuration Type”
code in each model number.
3. Specify two full model numbers per the desired configuration.
Additional Information
Specifications: page 68
Certifications: page 96
Dimensional Drawings: page 98
Rosemount 3051SAM Transmitter for ERS Applications
• Coplanar and In-Line sensor module platforms
• Variety of process connections including threaded NPT, flanges, manifolds, and 1199 remote
seals
• Available with 10-year stability and limited 12-year warranty
Table 7. 3051SAM Scalable Advanced Measurement Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common models and options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter Type
3051SAM Scalable Advanced Measurement Transmitter
Performance Class
Standard
Standard
1
Ultra: 0.025% span accuracy, 200:1 rangedown, 10-year stability, 12-year limited warranty
★
2
Classic: 0.055% span accuracy, 100:1 rangedown, 5-year stability
★
Configuration Type
Standard
Standard
P
Electronic Remote Sensor - Primary
★
S
Electronic Remote Sensor - Secondary
★
44
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 7. 3051SAM Scalable Advanced Measurement Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common models and options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Pressure Module Type
Standard
G
Coplanar
T
In-Line
E
In-Line
Expanded
A
Coplanar
Pressure Range(1)
Coplanar Gage
Standard
1A
N/A
2A
3A
4A
5A
-250 to 250 inH2O
(-623 to 623 mbar)
-393 to 1000 inH2O
(-0,98 to 2,49 bar)
-14.2 to 300 psig
(-0,98 to 20,7 bar)
-14.2 to 2000 psig
(-0,98 to 137,9 bar)
Pressure Sensor Type
Standard
★
★
★
Gage
Gage
Absolute
Absolute
In-Line Gage
In-Line Absolute
Coplanar Absolute
-14.7 to 30 psig
(-1,0 to 2,06 bar)
-14.7 to 150 psig
(-1,0 to 10,34 bar)
-14.7 to 800 psig
(-1,0 to 55,2 bar)
-14.7 to 4000 psig
(-1,0 to 275,8 bar)
-14.7 to 10000 psig
(-1,0 to 689,5 bar)
0 to 30 psia
(0 to 2,06 bar)
0 to 150 psia
(0 to 10,34 bar)
0 to 800 psia
(0 to 55,2 bar)
0 to 4000 psia
(0 to 275,8 bar)
0 to 10000 psia
(0 to 689,5 bar)
0 to 30 psia
(0 to 2,06 bar)
0 to 150 psia
(0 to 10,34 bar)
0 to 800 psia
(0 to 55,2 bar)
0 to 4000 psia
(0 to 275,8 bar)
N/A
Isolating Diaphragm
Standard
2(2)
316L SST
3(2)
Alloy C-276
Expanded
4(3)
Alloy 400
5(3)(4)
Tantalum
6(3)
Gold-plated Alloy 400 (includes Graphite-Filled PTFE O-Ring)
7(3)
Gold-plated 316L SST
Process Connection
Coplanar Module Type
In-Line Module Type
Standard
000
None
N/A
A11(5)
Assemble to Rosemount 305 Manifold
Assemble to Rosemount 306 Manifold
A12(5)
Assemble to Rosemount 304 or AMF Manifold with SST N/A
Traditional Flange
B11(5)(6)
Assemble to One Rosemount 1199 Remote Diaphragm Assemble to One Rosemount 1199 Remote Diaphragm
Seal with SST transmitter flange
E11
Coplanar Flange (CS), ¼-18 NPT, 316 SST Drain Vents ½ -14 NPT Female
E12
Coplanar Flange (SST), ¼-18 NPT, 316 SST Drain
N/A
Vents
E13(2)
Coplanar Flange (Cast C-276), ¼-18 NPT, Alloy C-276 N/A
Drain Vents
E14
Coplanar Flange (Cast Alloy 400), ¼-18 NPT, Alloy
N/A
400/K-500 Drain Vents
E15(2)
Coplanar Flange (SST), ¼-18 NPT, Alloy C-276 Drain
N/A
Vents
E16(2)
Coplanar Flange (CS), ¼-18 NPT, Alloy C-276 Drain
N/A
Vents
E21
Coplanar Flange (CS), RC ¼, 316 SST Drain Vents
N/A
E22
Coplanar Flange (SST), RC ¼, 316 SST Drain Vents
N/A
E23(2)
Coplanar Flange (Cast C-276), RC ¼, Alloy C-276
N/A
Drain Vents
E24
Coplanar Flange (Cast Alloy 400), RC ¼, alloy
N/A
400/K-500 Drain Vents
E25(2)
Coplanar Flange (SST), RC ¼, Alloy C-276 Drain Vents N/A
E26(2)
Coplanar Flange (CS), RC ¼, Alloy C-276 Drain Vents N/A
Standard
★
★
★
★
★
Standard
★
★
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
45
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 7. 3051SAM Scalable Advanced Measurement Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common models and options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
F12
Traditional Flange (SST), 1/4-18 NPT, 316 SST Drain
N/A
★
Vents
F13(2)
Traditional Flange (Cast C-276), 1/4-18 NPT, Alloy
N/A
★
C-276 Drain Vents
F14
Traditional Flange (Cast Alloy 400), 1/4-18 NPT, Alloy
N/A
★
400/K-500 Drain Vents
F15(2)
Traditional Flange (SST), 1/4-18 NPT, Alloy C-276 Drain N/A
★
Vents
F22
Traditional Flange (SST), RC ¼, 316 SST Drain Vents
N/A
★
F23(2)
Traditional Flange (Cast C-276), RC ¼, Alloy C-276
N/A
★
Drain Vents
F24
Traditional Flange (Cast Alloy 400), RC ¼, Alloy
N/A
★
400/K500 Drain Vents
F25(2)
Traditional Flange (SST), RC ¼, Alloy C-276 Drain
N/A
★
Vents
F52
DIN-Compliant Traditional Flange (SST), ¼-18 NPT,
N/A
★
316 Drain Vents, 7-16-in. Bolting
G11
Vertical Mount Level Flange (SST), 2-in ANSI Class
G ½ A DIN 16288 Male (Range 1-4 Only)
★
150, 316 SST Drain Vents
G12
Vertical Mount Level Flange (SST), 2-in ANSI Class
N/A
★
300, 316 SST Drain Vents
G21
Vertical Mount Level Flange (SST), 3-in ANSI Class
N/A
★
150, 316 SST Drain Vents
G22
Vertical Mount Level Flange (SST), 3-in ANSI Class
N/A
★
300, 316 SST Drain Vents
G31
Vertical Mount Level Flange (SST), DIN-DN 50 PN 40, N/A
★
316 SST Drain Vents
G41
Vertical Mount Level Flange (SST), DIN-DN 80 PN 40, N/A
★
316 SST Drain Vents
Expanded
F11
Traditional Flange (CS), ¼-18 NPT, 316 SST Drain /
Non-Threaded Instrument Flange (I-Flange)
Vents
F32
Bottom Vent Traditional Flange (SST), ¼-18 NPT, 316
N/A
SST Drain Vents
F42
Bottom Vent Traditional Flange (SST), RC ¼, 316 SST N/A
Drain Vents
F62
DIN-Compliant Traditional Flange (316 SST), ¼-18
N/A
NPT, 316 Drain Vents, M10 Bolting
F72
DIN-Compliant Traditional Flange (316 SST), ¼-18
N/A
NPT, 316 Drain Vents, M12 Bolting
Transmitter Output
Standard
Standard
A
4–20 mA with digital signal based on HART protocol
★
Housing Style
Material
Conduit Entry Size
Standard
Housings for ERS Primary - Configuration Type code P
1A
PlantWeb Housing
Aluminum
1B
PlantWeb Housing
Aluminum
1J
PlantWeb Housing
SST
1K
PlantWeb Housing
SST
2E
Junction Box with Remote Display
Aluminum
Output
2F
Junction Box with Remote Display
Aluminum
Output
2M
Junction Box with Remote Display
SST
Output
Housings for ERS Secondary - Configuration Type code S
2A
Junction Box
Aluminum
2B
Junction Box
Aluminum
2J
Junction Box
SST
46
Standard
1/2–14
NPT
M20 x 1.5 (CM 20)
1
/2–14 NPT
M20 x 1.5 (CM 20)
1/2–14 NPT
★
★
★
★
★
M20 x 1.5 (CM 20)
★
1
★
1
★
★
★
/2–14 NPT
/2–14 NPT
M20 x 1.5 (CM 20)
1
/2–14 NPT
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 7. 3051SAM Scalable Advanced Measurement Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common models and options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Expanded
Housings for ERS Primary - Configuration Type code P
1C
PlantWeb Housing
Aluminum
1L
PlantWeb Housing
SST
2G
Junction Box with Remote Display
Aluminum
Output
Housings for ERS Secondary - Configuration Type code S
2C
Junction Box
Aluminum
G1/2
G1/2
G1/2
G1/2
Options (Include with selected model number)
Electronic Remote Sensor Connection Cable
Standard
R05
50 ft. (15.2 m) Spool of Electronic Remote Sensor Cable
R10
100 ft. (30.5 m) Spool of Electronic Remote Sensor Cable
Mounting Bracket
Standard
B1(3)
Traditional flange bracket, CS, 2-in. pipe
B2(3)
Traditional flange bracket, CS, panel
B3(3)
Traditional flange flat bracket, CS, 2-in. pipe
B4
Bracket, all SST, 2-in. Pipe and Panel
B7(3)
Traditional flange bracket, B1 with SST bolts
B8(3)
Traditional flange bracket, B2 with SST bolts
B9(3)
Traditional flange bracket, B3 with SST bolts
BA(3)
Traditional flange bracket, B1, all SST
BC(3)
Traditional flange bracket, B3, all SST
Special Configuration (Software)
Standard
C1(7)
Customer Software Configuration (“Configuration Data Sheet” Must Be Completed)
C3
Gage Pressure Calibration on Rosemount 3051SAM_ _A4 only
C4(7)
NAMUR Alarm and Saturation Levels, High Alarm
C5(7)
NAMUR Alarm and Saturation Levels, Low Alarm
C6(7)
Custom Alarm and Saturation Levels, High Alarm (Requires C1 and Configuration Data Sheet)
C7(7)
Custom Alarm and Saturation Levels, Low Alarm (Requires C1 and Configuration Data Sheet)
C8(7)
Low alarm (standard Rosemount alarm and saturation levels)
Special Configuration (Hardware)
Standard
1/2-14 NPT Flange Adapters
D2(8)
D4
External ground screw assembly
D5(8)
Delete transmitter drain/vent valves (install plugs)
Expanded
D7(8)
Coplanar flange without drain/vent ports
D9(8)
RC 1/2 Flange Adapters
Product Certifications
Standard
E1
ATEX Flameproof
I1
ATEX Intrinsic Safety
N1
ATEX Type n
K1
ATEX Flameproof and Intrinsically Safe, Type n, Dust
ND
ATEX Dust
E4
TIIS Flameproof
E5
FM Explosion-proof, Dust Ignition-proof
I5
FM Intrinsically Safe, Division 2
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
E6(9)
CSA Explosion-proof, Dust Ignition-proof, Division 2
I6
CSA Intrinsically Safe
K6(9)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
E7
IECEx Flameproof
I7
IECEx Intrinsic Safety
Standard
★
★
Standard
★
★
★
★
★
★
★
★
★
Standard
★
★
★
★
★
★
★
Standard
★
★
★
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
47
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
Table 7. 3051SAM Scalable Advanced Measurement Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common models and options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
N7
IECEx Type n
K7
IECEx Flameproof, Intrinsic Safety, Type n
E2
INMETRO Flameproof
I2
INMETRO Intrinsically Safe
K2
INMETRO Flameproof, Intrinsic Safety, Type n
E3
China Flameproof
I3
China Intrinsic Safety
KA(9)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
KB(9)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
KD(9)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
Special Certifications
Standard
Q4
Calibration certificate
QP
Calibration Certificate and Tamper Evident Seal
Q8
Material Traceability Certification per EN 10204 3.1B
Q16
Surface Finish Certification for Hygienic Remote Seals
QZ(10)
Remote Seal System Performance Calculation Report
Terminal Blocks
Standard
T1(7)
Transient Terminal Block
Alternate Materials of Construction
Standard
L1(11)
Inert Sensor Fill Fluid
L2
Graphite-Filled PTFE O-Ring
L4(8)
Austenitic 316 SST Bolts
L5(2)(8)
ASTM A 193, Grade B7M Bolts
L6(8)
Alloy K-500 Bolts
L7(2)(8)
ASTM A 453, Class D, Grade 660 Bolts
L8(8)
ASTM A 193, Class 2, Grade B8M Bolts
Display Type (ERS Primary Only)
Standard
M5(7)
PlantWeb LCD Display
M7(7)
Remote Mount LCD Display and Interface, PlantWeb Housing, No Cable, SST Bracket
M8(7)
Remote Mount LCD Display and Interface, PlantWeb Housing, 50 ft. (15.2 m) Cable, SST Bracket
M9(7)
Remote Mount LCD Display and Interface, PlantWeb Housing, 100 ft. (30.5 m) Cable, SST Bracket
Special Procedures
Expanded
P1
Hydrostatic Testing with Certificate
P2(8)
Cleaning for Special Services
P3(8)
Cleaning for Less than 1 PPM Chlorine/Fluorine
Typical Model Number: 3051SAM 1 S T 2A 2 E11 A 2A
★
★
★
★
★
★
★
★
★
★
★
Standard
★
★
★
★
★
Standard
★
Standard
★
★
★
★
★
★
★
Standard
★
★
★
★
(1) The pressure range should be specified based on the maximum static pressure, not differential pressure.
(2) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
(3) Not available with Pressure Sensor / Module codes T or E.
(4) Tantalum diaphragm material is only available with Pressure Sensor / Module code G.
(5) “Assemble to” items are specified separately and require a completed model number.
(6) Consult an Emerson Process Management representative for performance specifications.
(7) Not available with Configuration Type code S.
(8) Not available with Process Connection code A11.
(9) Not available with M20 or G ½ conduit entry size.
(10) The QZ report quantifies the performance of the entire ERS system. One report is provided per ERS system. The QZ option is specified on the Primary
Transmitter (Configuration Type code P).
(11) Silicone fill fluid is standard.
48
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Rosemount 3051SAL Level Transmitter for ERS Applications
•
Integrated transmitter and remote seal in a single model number
•
Variety of process connections including flanged, threaded, and hygienic remote seals
•
Available with 10-year stability and limited 12-year warranty
A 3051SAL Transmitter consists of 3 parts. First, specify the transmitter model codes found on page 49. Then,
specify a remote seal found on page 59. Finish the model number by specifying all desired options on page 51.
ERS Transmitter Model Codes....page 49
Remote Seal Model Codes.......page 59
ERS Options.......page 51
Table 8. 3051SAL Scalable Advanced Level Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter Type
3051SAL
Scalable Advanced Level Transmitter
Performance Class
Standard
1
Ultra: 0.065% span accuracy, 100:1 rangedown, 12-year limited warranty
2
Classic: 0.065% span accuracy, 100:1 rangedown
Configuration Type
Standard
P
Electronic Remote Sensor - Primary
S
Electronic Remote Sensor - Secondary
Pressure Module Type
Pressure Sensor Type
Standard
G
Coplanar
Gage
T
In-Line
Gage
E
In-Line
Absolute
Expanded
A
Coplanar
Absolute
Pressure Range(5)
Coplanar Gage
In-Line Gage
In-Line Absolute
Coplanar
Absolute
Standard
1A
N/A
-14.7 to 30 psig
0 to 30 psia
0 to 30 psia
(-1,0 to 2,06 bar)
(0 to 2,06 bar)
(0 to 2,06 bar)
2A
-250 to 250 inH2O
-14.7 to 150 psig
0 to 150 psia
0 to 150 psia
(-623 to 623 mbar)
(-1,0 to 10,34 bar)
(0 to 10,34 bar)
(0 to 10,34 bar)
3A
-393 to 1000 inH2O
-14.7 to 800 psig
0 to 800 psia
0 to 800 psia
(-0,98 to 2,49 bar)
(-1,0 to 55,2 bar)
(0 to 55,2 bar)
(0 to 55,2 bar)
4A
-14.2 to 300 psig
-14.7 to 4000 psig
0 to 4000 psia
0 to 4000 psia
(-0,98 to 20,7 bar)
(-1,0 to 275,8 bar)
(0 to 275,8 bar)
(0 to 275,8 bar)
5A
-14.2 to 2000 psig
-14.7 to 10000 psig
0 to 10000 psia
N/A
(-0,98 to 137,9 bar)
(-1,0 to 689,5 bar)
(0 to 689 bar)
Transmitter Output
Standard
A
4-20 mA with Digital Signal Based on HART Protocol
Housing Style
Material
Standard
Housings for ERS Primary - Configuration Type code P
1A
PlantWeb Housing
Aluminum
1B
PlantWeb Housing
Aluminum
1J
PlantWeb Housing
SST
Standard
★
★
Standard
★
★
Standard
★
★
★
Standard
★
★
★
★
★
Standard
★
Conduit Entry
Size
Standard
1
/2–14 NPT
M20 x 1.5 (CM 20)
1/2–14 NPT
★
★
★
49
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
Table 8. 3051SAL Scalable Advanced Level Transmitter for ERS Applications Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
1K
PlantWeb Housing
SST
M20 x 1.5 (CM 20)
1
2E
Junction Box with Remote Display
Aluminum
/2–14 NPT
Output
2F
Junction Box with Remote Display
Aluminum
M20 x 1.5 (CM 20)
Output
1
2M
Junction Box with Remote Display
SST
/2–14 NPT
Output
Housings for ERS Secondary - Configuration Type code S
1
2A
Junction Box
Aluminum
/2–14 NPT
2B
Junction Box
Aluminum
M20 x 1.5 (CM 20)
1/2–14 NPT
2J
Junction Box
SST
Expanded
Housings for ERS Primary - Configuration Type code P
1C
PlantWeb Housing
Aluminum
G1/2
1L
PlantWeb Housing
SST
G1/2
2G
Junction Box with Remote Display
Aluminum
G1/2
Output
Housings for ERS Secondary - Configuration Type code S
2C
Junction Box
Aluminum
G1/2
Seal System Type
Standard
1
Direct-Mount Seal System
Direct-Mount Extension (Between Transmitter Flange and Seal)
Standard
0
No Extension
2
2-in. (50 mm) Extension
4
4-in. (100 mm) Extension
5
4-in. (100 mm) Thermal Optimizer Extension
Transmitter Reference Pressure Connection
Standard
00
None (In-Line Style Sensor)
20
316L SST Isolator / SST Transmitter Flange
30
Alloy C-276 Isolator / SST Transmitter Flange
Seal Fill Fluid
Specific
Temperature Limits(1)
Gravity
No Extension 2-in. (50 mm)
4-in. (100 mm)
Thermal
at 77 °F
Extension
Extension
Optimizer
(25 °C)
Standard
A
Syltherm XLT
0.85
-102 to 293 °F -102 to 293 °F -102 to 293 °F
-102 to 293 °F
(-75 to 145 °C) (-75 to 145 °C) (-75 to 145 °C)
(-75 to 145 °C)
C
Silicone 704
1.07
32 to 401 °F(2) 32 to 464 °F(2) 32 to 500 °F(2)
32 to 599 °F
(0 to 240 °C)
(0 to 315 °C)
(0 to 205 °C)
(0 to 260 °C)
D
Silicone 200
0.93
-49 to 401 °F
-49 to 401 °F
-49 to 401 °F
-49 to 401 °F
(-45 to 205 °C) (-45 to 205 °C) (-45 to 205 °C)
(-45 to 205 °C)
H
Inert (Halocarbon)
1.85
-49 to 320 °F
-49 to 320 °F
-49 to 320 °F
-49 to 320 °F
(-45 to 160 °C) (-45 to 160 °C) (-45 to 160 °C)
(-45 to 160 °C)
G(3)(4)
Glycerin and Water
1.13
5 to 203 °F
5 to 203 °F
5 to 203 °F
5 to 203 °F
(-15 to 95 °C)
(-15 to 95 °C)
(-15 to 95 °C)
(-15 to 95 °C)
N(3)
Neobee M-20
0.92
5 to 401 °F(2)
5 to 437 °F
5 to 437 °F
5 to 437 °F
(-15 to 205 °C) (-15 to 225 °C) (-15 to 225 °C)
(-15 to 225 °C)
P(3)(4)
Propylene Glycol and Water 1.02
5 to 203 °F
5 to 203 °F
5 to 203 °F
5 to 203 °F
(-15 to 95 °C)
(-15 to 95 °C)
(-15 to 95 °C)
(-15 to 95 °C)
50
★
★
★
★
★
★
★
Standard
★
Standard
★
★
★
★
Standard
★
★
★
Standard
★
★
★
★
★
★
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Continue specifying a completed model number by choosing a remote seal type below:
page 59
FF Flush Flanged Seal
Process Connections:
2 in. / DN 50 / 50A
3 in. / DN 80 / 80A
4 in. / DN 100 / 100A
page 61
EF Extended Flanged Seal
Process Connections:
3 in. / DN 80 / 80A
4 in. / DN 100 / 100A
page 62
RF Remote Flanged Seal
Process Connections:
1 in. / DN 25 / 25A
1.5 in. / DN 40 / 40A
page 64
RT Remote Threaded Seal
Process Connections:
¼ - 18 NPT
½ - 14 NPT
¾ - 14 NPT
1 – 11.5 NPT
page 66
SC Hygienic Tri-Clamp Seal
Process Connections:
1.5 in.
2 in.
3 in.
page 67
SS Hygienic Tank Spud Seal
Process Connections:
4 in.
Options (Include with selected model number)(1)(2)(3) (4)
Electronic Remote Sensor Connection Cable
Standard(5)
R05
50 ft. (15.2 m) Spool of Electronic Remote Sensor Cable
R10
100 ft. (30.5 m) Spool of Electronic Remote Sensor Cable
Special Configuration (Software)
Standard
C1(6)
Customer Software Configuration (“Configuration Data Sheet” Must Be Completed)
C3
Gage Pressure Calibration on Rosemount 3051SAL_ _A4 only
C4(6)
NAMUR Alarm and Saturation Levels, High Alarm
C5(6)
NAMUR Alarm and Saturation Levels, Low Alarm
C6(6)
Custom Alarm and Saturation Levels, High Alarm (Requires C1 and Configuration Data Sheet)
C7(6)
Custom Alarm and Saturation Levels, Low Alarm (Requires C1 and Configuration Data Sheet)
C8(6)
Low Alarm (Standard Rosemount Alarm and Saturation Levels)
Special Configuration (Hardware)
Standard
D4
External Ground Screw Assembly
Product Certifications
Standard
E1
ATEX Flameproof
I1
ATEX Intrinsic Safety
N1
ATEX Type n
K1
ATEX Flameproof and Intrinsically Safe, Type n, Dust
ND
ATEX Dust
E4
TIIS Flameproof
E5
FM Explosion-proof, Dust Ignition-proof
I5
FM Intrinsically Safe, Division 2
Standard
★
★
Standard
★
★
★
★
★
★
★
Standard
★
Standard
★
★
★
★
★
★
★
★
51
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
E6(7)
CSA Explosion-proof, Dust Ignition-proof, Division 2
I6
CSA Intrinsically Safe
K6(7)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
E7
IECEx Flameproof
I7
IECEx Intrinsic Safety
N7
IECEx Type n
K7
IECEx Flameproof, Intrinsic Safety, Type n
E2
INMETRO Flameproof
I2
INMETRO Intrinsically Safe
K2
INMETRO Flameproof, Intrinsic Safety, Type n
KA(7)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
KB(7)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
KD(7)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
Alternate Materials of Construction
Standard
L1(8)
Inert Sensor Fill Fluid
L2
Graphite-Filled PTFE O-Ring
L4
Austenitic 316 SST Bolts
L5(9)
ASTM A 193, Grade B7M Bolts
L6
Alloy K-500 Bolts
L7(9)
ASTM A 453, Class D, Grade 660 Bolts
L8
ASTM A 193, Class 2, Grade B8M Bolts
Display Type (ERS Primary Only)
Standard
M5(6)
PlantWeb LCD Display
M7(6)
Remote Mount LCD Display and Interface, PlantWeb Housing, No Cable, SST Bracket
M8(6)
Remote Mount LCD Display and Interface, PlantWeb Housing, 50 ft. (15.2 m) Cable, SST Bracket
M9(6)
Remote Mount LCD Display and Interface, PlantWeb Housing, 100 ft. (30.5 m) Cable, SST Bracket
Special Procedures
Expanded
P1
Hydrostatic Testing with Certificate
P2
Cleaning for Special Services
P3
Cleaning for Less than 1 PPM Chlorine/Fluorine
Special Certifications
Standard
Q4
Calibration Certificate
QP
Calibration certificate with tamper evident seal
Q8
Material traceability certification per EN 10204 3.1
QZ(10)
Remote Seal System Performance Calculation Report
Transient Protection
Standard
T1(6)
Transient Terminal Block
Typical Model Number: 3051SAL 1 P G 4A A 1A 1 0 20 D FF 7 1 DA 0 0 M5
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
Standard
★
★
★
★
★
★
★
Standard
★
★
★
★
Standard
★
★
★
★
Standard
★
(1) At ambient pressure of 14.7 psia (1 bar-a) and ambient temperature of 70°F (21°C).
(2) Maximum process temperature is limited by heat transfer to the transmitter electronics and must be further derated if ambient.
(3) This is a food grade fill fluid.
(4) Not suitable for vacuum applications.
(5) The pressure range should be specified based on the maximum static pressure, not differential pressure.
(6) Not available with Configuration Type code S.
(7) Not available with M20 or G ½ conduit entry size.
(8) Silicone fill fluid is standard.
(9) Materials of construction comply with metallurgical requirements highlighted within NACE MR0175 / ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
(10) The QZ report quantifies the performance of the entire ERS system. One report is provided per ERS system. The QZ option is specified on the Primary
Transmitter (Configuration Type code P).
52
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Rosemount 3051S Liquid Level Transmitter
3051SAL In-Line with
“FF” Flanged Seal
Rosemount 3051S liquid level transmitters combine the scalable features
and benefits of a high-performance 3051S transmitter with the durability and
reliability of a remote diaphragm seal all in a single model number.
Level transmitters can also be ordered with an additional 1199 remote seal
to form a Tuned-System Assembly that offers improved performance and
reduced costs compared to traditional symmetrical (balanced) assemblies.
3051SAL Coplanar
with “SS” Hygienic
Tank Spud Seal
Product features and capabilities include:
• Variety of process connections including flanged, threaded, and hygienic
seals
• Quantified performance for the entire transmitter / seal assembly (QZ
option)
Tuned-System
Assembly Comprised
of 3051SAL with
1199 Flanged Seal
• HART, FOUNDATION fieldbus, and Wireless protocols
Additional Information
Specifications: page 68
Dimensional Drawings: page 98
Rosemount 3051SAL Liquid Level Transmitter
A 3051SAL Transmitter consists of 3 parts. First, specify the transmitter model codes found on page 53. Then,
specify a remote seal found on page 59. Finish the model number by specifying all desired options on page 55.
Transmitter Model Codes........page 53
Remote Seal Model Codes........page 59
Transmitter Options...page 55
Table 9. Rosemount 3051S Liquid Level Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter Type
3051SAL
Scalable Advanced Level Transmitter for Liquid Level Applications
Performance Class
Standard
1
2
Ultra: 0.065% Span Accuracy, 100:1 Rangedown, 12-Year Limited Warranty
Classic: 0.065% Span Accuracy, 100:1 Rangedown
Standard
★
★
Configuration Type
Standard
C
Pressure Module Type
Standard
D
G
T
E
Expanded
A
Standard
★
Liquid Level Transmitter
Pressure Sensor Type
Coplanar
Coplanar
In-Line
In-Line
Differential
Gage
Gage
Absolute
Coplanar
Absolute
Standard
★
★
★
★
53
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 9. Rosemount 3051S Liquid Level Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Pressure Range
Standard
1A
2A
3A
4A
5A
Coplanar DP
Coplanar Gage
In-Line Gage
In-Line
Absolute
Coplanar Absolute
N/A
N/A
-250 to 250 inH2O
(-623 to 623 mbar)
-1000 to 1000 inH2O
(-2,5 to 2,5 bar)
-300 to 300 psi
(-20,7 to 20,7 bar)
-2000 to 2000 psi
(-137,9 to 137,9 bar)
-250 to 250 inH2O
(-623 to 623 mbar)
-393 to 1000 inH2O
(-0,98 to 2,5 bar)
-14.2 to 300 psig
(-0,98 to 20,7 bar)
-14.2 to 2000 psig
(-0,98 to 137,9 bar)
-14.7 to 30 psig
(-1,0 to 2,06 bar)
-14.7 to 150 psig
(-1,0 to 10,3 bar)
-14.7 to 800 psig
(-1,0 to 55,2 bar)
-14.7 to 4000 psig
(-1,0 to 275,8 bar)
-14.7 to 10000 psig
(-1,0 to 689 bar)
0 to 30 psia
(0 to 2,06 bar)
0 to 150 psia
(0 to 10,34 bar)
0 to 800 psia
(0 to 55,2 bar)
0 to 4000 psia
(0 to 275,8 bar)
0 to 10000 psia
(0 to 689 bar)
0 to 30 psia
(0 to 2,06 bar)
0 to 150 psia
(0 to 10,34 bar)
0 to 800 psia
(0 to 55,2 bar)
0 to 4000 psia
(0 to 275,8 bar)
N/A
Standard
★
★
★
★
★
Transmitter Output
Standard
A
F(10)
X(11)
Standard
★
★
★
4-20 mA with digital signal based on HART protocol
FOUNDATION fieldbus protocol
Wireless (Requires wireless options and wireless PlantWeb housing)
Housing Style
Material(17)
Standard
1A
1B
1J
1K
2A
2B
2E
2F
2J
5A(5)
5J(5)
7J(12)
PlantWeb housing
PlantWeb housing
PlantWeb housing
PlantWeb housing
Junction Box housing
Junction Box housing
Junction Box with output for remote interface
Junction Box with output for remote interface
Junction Box housing
Wireless PlantWeb housing
Wireless PlantWeb housing
Quick Connect (A size Mini, 4-pin male
termination)
Aluminum
Aluminum
SST
SST
Aluminum
Aluminum
Aluminum
Aluminum
SST
Aluminum
SST
SST
1
PlantWeb housing
PlantWeb housing
Junction Box housing
Junction Box with output for remote interface
Aluminum
316L SST
Aluminum
Aluminum
G1/2
G1/2
G1/2
G1/2
Expanded
1C
1L
2C
2G
Conduit Entry
/2–14 NPT
M20 x 1.5
1/2–14 NPT
M20 x 1.5
1/2–14 NPT
M20 x 1.5
1
/2–14 NPT
M20 x 1.5
1/2–14 NPT
1
/2–14 NPT
1/2–14 NPT
Standard
★
★
★
★
★
★
★
★
★
★
★
★
Direct-Mount Extension (Between Transmitter Flange and Seal)
Standard
10
12
14
15
No Extension
2-in. (50 mm) Extension
4-in. (100 mm) Extension
4-in. (100 mm) Thermal Optimizer Extension
Standard
★
★
★
★
Transmitter Reference Pressure Connection
Standard
00
10(13)
20
30
54
None (Inline Module Type Only)
Tuned-System Assembly, One Capillary Remote Seal (Requires separate 1199 model number)
316 L SST Isolator with SST Transmitter Flange
Alloy C-276 Isolator with SST Transmitter Flange
Standard
★
★
★
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 9. Rosemount 3051S Liquid Level Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
(1)
Seal Fill Fluid
Specific Gravity at Temperature Limits
77 °F (25 °C)
No Extension
2-in. (50 mm)
4-in. (100 mm)
Thermal
Extension
Extension
Optimizer
Standard
A
Syltherm XLT
0.85
-102 to 293 °F
-102 to 293 °F
102 to 293 °F
102 to 293 °F
(-75 to 145 °C)
(-75 to 145 °C) (-75 to 145 °C)
C
Silicone 704
1.07
32 to 401 °F
32 to 464 °F
32 to 500 °F
32 to 599 °F
(0 to 205 °C)(2)
(0 to 240 °C)(2) (0 to 260 °C)(2)
(0 to 315 °C)
D
Silicone 200
0.93
-49 to 401 °F
-49 to 401 °F
-49 to 401 °F
-49 to 401 °F
(-45 to 205 °C)
(-45 to 205 °C) (-45 to 205 °C) (-45 to 205 °C)
H
Inert (Halocarbon)
1.85
-49 to 320 °F
-49 to 320 °F
-49 to 320 °F
-49 to 320 °F
(-45 to 160 °C)
(-45 to 160 °C) (-45 to 160 °C) (-45 to 160 °C)
G(3)(4)
Glycerine and Water
1.13
5 to 203 °F
5 to 203 °F
5 to 203 °F
5 to 203 °F
(-15 to 95 °C)
(-15 to 95 °C)
(-15 to 95 °C)
(-15 to 95 °C)
N(3)
Neobee M-20
0.92
5 to 401 °F
5 to 437 °F
5 to 437 °F
5 to 437 °F
(-15 to 205 °C)(2)
(-15 to 225 °C) (-15 to 225 °C) (-15 to 225 °C)
P(3)(4)
Propylene Glycol
1.02
5 to 203 °F
5 to 203 °F
5 to 203 °F
5 to 203 °F
and Water
(-15 to 95 °C)
(-15 to 95 °C)
(-15 to 95 °C)
(-15 to 95 °C)
Standard
★
★
★
★
★
★
★
Continue specifying a completed model number by choosing a remote seal type below:
page 59
FF Flush Flanged Seal
Process Connections:
2 in. / DN 50 / 50A
3 in. / DN 80 / 80A
4 in. / DN 100 / 100A
page 61
EF Extended Flanged Seal
Process Connections:
3 in. / DN 80 / 80A
4 in. / DN 100 / 100A
page 62
RF Remote Flanged Seal
Process Connections:
1 in. / DN 25 / 25A
1.5 in. / DN 40 / 40A
page 64
RT Remote Threaded Seal
Process Connections:
¼ - 18 NPT
½ - 14 NPT
¾ - 14 NPT
1 – 11.5 NPT
page 66
SC Hygienic Tri-Clamp Seal
Process Connections:
1.5 in.
2 in.
3 in.
page 67
SS Hygienic Tank Spud Seal
Process Connections:
4 in.
Wireless Options (Requires option code X and wireless PlantWeb housing)(1)(2) (3) (4)
Update Rate
Standard(5)
WA
User Configurable Update Rate
Operating Frequency and Protocol
Standard
3
2.4 GHz DSSS, IEC 62591 (WirelessHART)
Standard
★
★
55
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
Omnidirectional Wireless Antenna
Standard
WK
External Antenna
WM
Extended Range, External Antenna
Expanded
WN
High-Gain, Remote Antenna
SmartPower™
Standard
1(6)
Adapter for Black Power Module (I.S. Power Module Sold Separately)
★
★
★
Other Options (Include with selected model number)
PlantWeb Control Functionality
Standard
A01(7)(8)
FOUNDATION fieldbus Advanced Control Function Block Suite
PlantWeb Diagnostic Functionality
Standard
D01(7)(8)
FOUNDATION fieldbus Diagnostics Suite
DA2(9)
Advanced HART Diagnostics Suite
Special Configuration (Software)
Standard(10)(11)(12)(13)
C1(14)
Custom software configuration (Requires Configuration Data Sheet)
C3
Gage pressure calibration on Rosemount 3051SAL_ _A4 only
C4(7)(14)
NAMUR alarm and saturation levels, high alarm
C5(7)(14)
NAMUR alarm and saturation levels, low alarm
C6(7)(14)
Custom alarm and saturation signal levels, high alarm (Requires C1 and Configuration Data Sheet)
C7(7)(14)
Custom alarm and saturation signal levels, low alarm (Requires C1 and Configuration Data Sheet)
C8(7)(14)
Low alarm (standard Rosemount alarm and saturation levels)
Special Configuration (Hardware)
Standard
DO(15)
316 SST Conduit Plug
D1(7)(14)(16)
Hardware adjustments (zero, span, alarm, security)
1/2-14 NPT flange adapter
D2
D4
External ground screw assembly
D5
Delete transmitter drain/vent valves (install plugs)
D9
RC 1/2 SST flange adapter
Product Certifications(17)
Standard
E1
ATEX Flameproof
I1
ATEX Intrinsic Safety
IA
ATEX FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only)
N1
ATEX Type n
K1
ATEX Flameproof, Intrinsic Safety, Type n, Dust
ND
ATEX Dust
E4
TIIS Flameproof
E5
FM Explosion-proof, Dust Ignition-proof
I5
FM Intrinsically Safe, Division 2
IE
FM FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only)
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
E6(18)
CSA Explosion-proof, Dust Ignition-proof, Division 2
I6
CSA Intrinsically Safe
IF
CSA FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only)
K6(18)
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
D3(19)
Measurement Canada Accuracy Approval
E7
IECEx Flameproof, Dust Ignition-proof
I7
IECEx Intrinsic Safety
IG
IECEx FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only)
N7
IECEx Type n
56
Standard
★
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n
E2
INMETRO Flameproof
I2
INMETRO Intrinsic Safety
K2
INMETRO Flameproof, Intrinsic Safety
E3
China Flameproof
I3
China Intrinsic Safety
KA(18)
ATEX and CSA Flameproof, Intrinsically Safe, Division 2
KB(18)
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, Division 2
KC
FM and ATEX Explosion-proof, Intrinsically Safe, Division 2
KD(18)
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe
Alternate Materials of Construction
Standard
L1(20)
Inert sensor fill fluid
L2
Graphite-filled PTFE o-ring
L4
Austenitic 316 SST bolts
L5(21)
ASTM A193, Grade B7M bolts
L6
Alloy K-500 bolts
L7(21)
ASTM A453, Class D, Grade 660 bolts
L8
ASTM A193, Class 2, Grade B8M bolts
Display Type(22)
Standard
M5
PlantWeb LCD Display
M7(7)
Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracket
M8(7)
Remote mount LCD display and interface, PlantWeb housing, 50 ft. (15 m) cable, SST bracket
M9(7)
Remote mount LCD display and interface, PlantWeb housing, 100 ft. (31 m) cable, SST bracket
Special Procedures
Expanded
P1
Hydrostatic testing with certificate
P2
Cleaning for special services
P3
Cleaning for less than 1PPM chlorine/fluorine
Special Certification
Standard
Q4
Calibration certificate
QP
Calibration certificate and tamper evident seal
Q8
Material traceability certification per EN 10204 3.1.B
QS(7)(14)
Prior-use certificate of FMEDA Data
QT(23)
Safety-certified to IEC 61508 with certificate of FMEDA data
QZ
Remote Seal System Performance Calculation Report
Transient Protection
Standard
T1(24)(25)
Transient terminal block
Conduit Electrical Connector
Standard
GE(26)
M12, 4-pin, Male Connector (eurofast®)
GM(26)
A size Mini, 4-pin, Male Connector (minifast®)
Typical Model Number: 3051SAL 1 C G 2A A 1A 10 20 D FF G 1 DA 0 0
★
★
★
★
★
★
★
★
★
★
Standard
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
(1) At ambient pressure of 14.7 psia (1 bar-a) and ambient temperature of 70°F (21°C)
(2) Maximum process temperature is limited by heat transfer to the transmitter
(3) This is a food grade fill fluid.
(4) Not suitable for vacuum applications.
(5) Only available with output code X.
(6) Long-Life Power Module must be shipped separately, order Part #00753-9220-0001.
(7) Not available with output code X.
(8) Not available with output code A.
(9) Requires PlantWeb housing and Output code A. Includes Hardware Adjustments as standard.
57
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
(10) Requires PlantWeb housing.
(11) Available approvals are FM Intrinsically Safe, Division 2 (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1),
and IECEx Intrinsic Safety (option code I7).
(12) Available with output code A only. Available approvals are FM Intrinsically Safe, Division 2 (option code I5), ATEX Intrinsic Safety (option code I1), or IECEx
Intrinsic Safety (option code I7). Contact an Emerson Process Management representative for additional information.
(13) With option code 10, user must select Seal Location option code M in Table 7 of Rosemount DP Level PDS.
(14) Not available with output code F.
(15) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of carbon steel conduit plug.
(16) Not available with housing style codes 2E, 2F, 2G, 2M, 5A, 5J, or 7J.
(17) Valid when SuperModule Platform and housing have equivalent approvals.
(18) Not available with M20 or G ½ conduit entry size.
(19) Requires PlantWeb housing and Hardware Adjustments option code D1. Limited availability depending on transmitter type and range. Contact an Emerson
Process Management representative for additional information.
(20) Silicone fill fluid is standard.
(21) Materials of construction comply with metallurgical requirements highlighted within NACE MR0175 / ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
(22) Not available with Housing code 01 or 7J.
(23) Not available with output code F or X. Not available with housing code 01 or 7J.
(24) Not available with Housing code 00, 01, 5A, or 7J.
(25) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IE, IF, and IG.
(26) Not available with Housing code 00, 01, 5A, or 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Division 2 (option code I5) or
FM FISCO Intrinsically Safe (option code IE), install in accordance with Rosemount drawing 03151-1009 to maintain outdoor rating (NEMA 4X and IP66).
58
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Direct Mount Seals for 3051SAL
Flush Flanged (FF) Seal
•
Most common seal
•
Good for use in general applications
•
Easy installation on flanged connections ranging from 2-in. (DN 50) to 4-in. (DN 100)
Table 10. Flush Flanged (FF) Seal Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Process Connection
FF
Flush Flanged Seal
Process Connection Size
Standard
G
2-in. / DN 50 / 50A
7
3-in. / 80A
J
DN 80
9
4-in. / DN 100 / 100A
Flange / Pressure Rating
Standard
1
Class 150 per ANSI/ASME B16.5
2
Class 300 per ANSI/ASME B16.5
4
Class 600 per ANSI/ASME B16.5
G
PN 40 per EN 1092-1
Expanded
A
10K per JIS B2238
B
20K per JIS B2238
D
40K per JIS B2238
E
PN 10/16 per EN 1092-1 (DN 100 only)
Materials of Construction
Isolating Diaphragm
Upper Housing
Flange
Standard
CA
316L SST
316L SST
CS
DA
316L SST
316L SST
316 SST
CB(1)
Alloy C-276
316L SST
CS
DB(1)
Alloy C-276
316L SST
316 SST
CC
Tantalum
316L SST
CS
DC
Tantalum
316L SST
316 SST
Flushing Connection Ring (Lower Housing)(2)
Standard
0
None
A
316 SST
B
Alloy C-276
Flushing Connection Quantity & Size
Standard
0
None
1
One 1/4-18 NPT Flushing Connection
3
Two 1/4-18 NPT Flushing Connections
7
One 1/2-14 NPT Flushing Connection
9
Two 1/2-14 NPT Flushing Connections
Standard
★
★
★
★
Standard
★
★
★
★
Standard
★
★
★
★
★
★
Standard
★
★
★
Standard
★
★
★
★
★
59
Product Data Sheet
Rosemount 3051S Series
00813-0100-4801, Rev PA
April 2011
Table 10. Flush Flanged (FF) Seal Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Options (Include with selected model number)
Flushing Connection Ring Plugs
Standard
SD
Alloy C-276 Plug(s) for Flushing Connection(s)
SG
SST Plug(s) for Flushing Connection(s)
SH
SST Drain / Vent(s) for Flushing Connection(s)
Flushing Connection Ring Gaskets
Expanded
SK
Barium Sulfate-Filled PTFE Gasket
SN
Grafoil Gasket
Additional Options
Expanded
SB
Extra Fill Fluid for Cold Temperature Applications
SJ
PTFE Gasket
SC(3)
0.006-in. (150 μm) Diaphragm Thickness
ST(4)
Wetted Materials Compliance to NACE MR 0175 / ISO 1516, MR 0103
SU(3)
0.001-in. (25 μm) Gold Plated Diaphragm
SV(5)
PTFE Coated Diaphragm for Non-Stick Purposes
Standard
★
★
★
Complete the 3051SAL model number by specifying options as needed:
ERS Transmitter Options, see page 51
Liquid Level Transmitter Options, see page 55
(1) Not available with option code SC.
(2) Supplied with Thermo Tork TN9000 gasket.
(3) Not available with Tantalum diaphragms (Material of Construction codes CC and DC).
(4) Materials of construction comply with metallurgical requirements highlighted within NACE MR0175 / ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
(5) Not available with transmitter option code Q8 (Material Traceability per EN 10204 3.1)
60
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Extended Flanged (EF) Seal
•
Good for use in viscous applications with plugging issues
•
Seal diaphragm installed flush with inner tank wall to prevent process plugging
•
Easy installation on 3-in. (DN 80) and 4-in. (DN 100) flanged connections
Table 11. Extended Flanged (EF) Seal Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Process Connection
EF
Extended Flanged Seal
Process Connection Size
Standard
7
3-in. / DN 80 / 80A
9
4-in. / DN 100 / 100A
Flange / Pressure Rating
Standard
1
Class 150 per ANSI/ASME B16.5
2
Class 300 per ANSI/ASME B16.5
4
Class 600 per ANSI/ASME B16.5
G
PN 40 per EN 1092-1
Expanded
A
10K per JIS B2238
B
20K per JIS B2238
D
40K per JIS B2238
E
PN 10/16 per EN 1092-1 (DN 100 only)
Materials of Construction
Isolating Diaphragm
Extension / Gasket Surface
Standard
CA
316L SST
316L SST
DA
316L SST
316L SST
CB
Alloy C-276
Alloy C-276
DB
Alloy C-276
Alloy C-276
Seal Extension Length
Standard
20
2-in. (50 mm)
40
4-in. (100 mm)
60
6-in. (150 mm)
Standard
★
★
Standard
★
★
★
★
Mounting Flange
CS
316 SST
CS
316 SST
Standard
★
★
★
★
Standard
★
★
★
Options (Include with selected model number)
Standard
ST(1)
SB
Expanded
SC
SU
SV(2)
Wetted Materials Compliance per NACE MR 0175 / ISO 1516, MR 0103
Extra Fill Fluid for Cold Temperature Applications
Standard
★
★
0.0016-in. (150 μm) Diaphragm Thickness
0.001-in. (25 μm) Gold Plated Diaphragm
PTFE Coated Diaphragm for Non-Stick Purposes
Complete the 3051SAL model number by specifying options as needed:
ERS Transmitter Options, see page 51
Liquid Level Transmitter Options, see page 55
(1) Materials of construction comply with metallurgical requirements highlighted within NACE MR0175 / ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
(2) Not available with transmitter option code Q8 (Material Traceability per EN 10204 3.1)
61
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Remote Flanged (RF) Seal
•
Designed to improve performance on smaller process connections
•
Easy installation on flanged connections ranging from 1-in. to 1.5-in. (DN 50 – DN 40)
•
Lower housing / flushing ring required
Table 12. Remote Flanged (RF) Seal Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Process Connection
RF
Remote Flanged Seal
Process Connection Size
Standard
2
1-in. / 25A
4
1.5-in. / 40A
D
DN 25
F
DN 40
Flange / Pressure Rating
Standard
1
Class 150 per ANSI/ASME B16.5
2
Class 300 per ANSI/ASME B16.5
4
Class 600 per ANSI/ASME B16.5
G
PN 40 per EN 1092-1
Expanded
A
10K per JIS B2238
B
20K per JIS B2238
D
40K per JIS B2238
Materials of Construction
Isolating Diaphragm
Upper Housing
Standard
CA
316L SST
316L SST
DA
316L SST
316L SST
CB
Alloy C-276
316L SST
DB
Alloy C-276
316L SST
CC
Tantalum
316L SST
DC
Tantalum
316L SST
Flushing Connection Ring Material (Lower Housing)(1)
Standard
A
316L SST
B
Alloy C-276
D
Plated CS
Number of Flushing Connections
Standard
1
One ¼-18 NPT Flushing Connection
3
Two ¼-18 NPT Flushing Connections
5
None
Standard
★
★
★
★
Standard
★
★
★
★
Flange
CS
316 SST
CS
316 SST
CS
316 SST
Standard
★
★
★
★
★
★
Standard
★
★
★
Standard
★
★
★
Options (Include with selected model number)
Flushing Connection Ring Plugs
Standard
SD
Alloy C-276 Plugs
SG
316 SST Plugs
SH
316 SST Drain / Vents
Flushing Connection Ring Gaskets
Standard
SJ
PTFE Gasket
62
Standard
★
★
★
Standard
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 12. Remote Flanged (RF) Seal Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Expanded
SK
Barium Sulfate-Filled PTFE Gasket
SN
Grafoil Gasket
SR
Ethylene Propylene Gasket
Additional Options
Standard
ST(2)
Wetted Materials Compliance per NACE MR 0175 / ISO 1516, MR 0103
SB
Extra Fill Fluid for Cold Temperature Applications
Expanded
SC(3)
0.006-in. (150 μm) Diaphragm Thickness
SU(3)
0.001-in. (25 μm) Gold Plated Diaphragm
SV(4)
PTFE Coated Diaphragm for Non-Stick Purposes
Standard
★
★
Complete the 3051SAL model number by specifying options as needed:
ERS Transmitter Options, see page 51
Liquid Level Transmitter Options, see page 55
(1) Supplied with C4401 Aramid fiber gasket.
(2) Materials of construction comply with metallurgical requirements highlighted within NACE MR0175 / ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
(3) Not available with Tantalum diaphragms (Material of Construction codes CC and DC).
(4) Not available with transmitter option code Q8 (Material Traceability per EN 10204 3.1)
63
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Remote Threaded (RT) Seal
•
For use with threaded process connections (1/4-18 to 1-11.5 NPT)
•
Rated for use in high-pressure applications (up to 2500 PSI)
•
Optional flushing connections available
Table 13. RT Threaded Seal Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Process Connection Style
Standard
RT
Standard
★
Remote Threaded Seal
Process Connection Size
Standard
3
4
5
Expanded
1
Standard
★
★
★
1/2-14
NPT
3/4-14 NPT
1-11.5 NPT
1/4-18
NPT
Pressure Rating
Standard
0
Standard
★
2500 psi
Isolating Diaphragm Material
Upper Housing Material
Flange
Standard
CA
DA
CB
DB
CC
DC
316L SST
316L SST
316L SST
316L SST
316L SST
316L SST
CS
316 SST
CS
316 SST
CS
316 SST
316L SST
316L SST
Alloy C-276
Alloy C-276
Tantalum
Tantalum
Standard
★
★
★
★
★
★
Flushing Connection Ring Material (Lower Housing)(1) (2)
Standard
A
B
Expanded
D
316L SST
Alloy C-276
Standard
★
★
Plated CS
Number of Flushing Connections
Standard
1
3
5
One 1/4-in. Flushing Connection
Two 1/4-in. Flushing Connections
No Flushing Connection
Standard
★
★
★
Options (Include with selected model number)
Flushing Connection Ring Plugs
Standard
SD
Alloy C-276 Plugs
SG
316 SST Plugs
SH
316 SST Drain / Vents
Flushing Connection Ring Gaskets
Standard
SJ
PTFE Gasket
SN
Grafoil Gasket
SR
Ethylene Propylene Gasket
64
Standard
★
★
★
Standard
★
★
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Table 13. RT Threaded Seal Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Expanded
SK
Barium Sulfate-Filled PTFE Gasket
Bolting
Standard
S3
304 SST Bolts
Expanded
S4
S16 SST Bolts
Additional Options
Standard
ST(3)
Wetted Materials Compliance per NACE MR 0175 / ISO 1516, MR 0103
SB
Extra Fill Fluid for Cold Temperature Applications
Expanded
SC(4)
0.006-in. (150 μm) Diaphragm Thickness
SU(4)
0.001-in. (25 μm) Gold Plated Diaphragm
SV(5)
PTFE Coated Diaphragm for Non-Stick Purposes
Standard
★
Standard
★
★
Complete the 3051SAL model number by specifying options as needed:
ERS Transmitter Options, see page 51
Liquid Level Transmitter Options, see page 55
(1) Supplied with C4401 aramid fiber gasket.
(2) Flushing Connection Ring/ Lower Housing assembly bolts provided as standard are carbon steel.
(3) Materials of construction comply with metallurgical requirements highlighted within NACE MR0175 / ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
(4) Not available with Tantalum diaphragms (Material of Construction codes CC and DC).
(5) Not available with transmitter option code Q8 (Material Traceability per EN 10204 3.1)
65
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Hygienic Tri-Clamp (SC) Seal
•
Good for use in hygienic applications
•
Easy installation on Tri-Clover style Tri-Clamp connections (1.5-in. to 3-in.)
•
Conforms to 3-A standard 74-03
Table 14. SC Hygienic Tri-Clover Style Tri-Clamp Seal Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Process Connection
Standard
SC(1)
Standard
★
Tri-Clover Style Tri-Clamp Seal
Process Connection Size
Standard
3(2)
5(2)
7
Standard
★
★
★
1½ in.
2 in.
3 in.
Maximum Working Pressure
Standard
0
Isolating Diaphragm Material
Standard
LA00
Expanded
LB00
Standard
★
1000 PSI
Upper Housing Material
316L SST
316L SST
Alloy C-276
316L SST
Standard
★
Options (Include with selected model number)
Diaphragm Surface Finish and Polishing
Expanded
R6
RD
RG
RH
Electropolishing
10 in. (0.25 m) Ra Diaphragm Surface Finish
15 in. (0.375 m) Ra Diaphragm Surface Finish
20 in. (0.5 m) Ra Diaphragm Surface Finish
Certifications
Standard
Q16
Surface Finish Certification
Complete the 3051SAL model number by specifying options as needed:
ERS Transmitter Options, see page 51
Liquid Level Transmitter Options, see page 55
(1) Clamp and gasket furnished by user. The maximum working pressure is dependent upon the clamp pressure rating.
(2) Consult factory for calibrated spans lower than 5 psi (345 mbar).
66
Standard
★
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Hygienic Tank Spud (SS) Seal
•
Commonly used in hygienic level applications
•
Seal diaphragm installed flush with inner tank wall
•
Conforms to 3-A standard 74-03
Table 15. SS Hygienic Tank Spud Seal Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Process Connection
Standard
Hygienic Tank Spud Seal
SS(1)
Process Connection Size
Standard
★
Standard
A
4-in. Sch. 5 Tri-Clamp
Maximum Working Pressure (Clamp Rating)
Standard
★
Standard
0
600 PSI (41 bar)
Upper Housing
Standard
★
Standard
A
316L SST
Diaphragm and Wetted, Extension Material
Standard
★
Diaphragm and Wetted
Standard
AL
316L SST(2)
Expanded
BB
Alloy C-276
Extension Length
Standard
2
6
Extension
316L SST(2)
Standard
★
316L SST
2 in. (50 mm) Extension
6 in. (150 mm) Extension
Standard
★
★
Options (Include with selected model number)
Diaphragm Surface Finish and Polishing
Expanded
R6
Electropolishing
RH
20 in. (0.5 m) Ra Diaphragm Surface Finish
RG(3)
15 in. (0.375 m) Ra Diaphragm Surface Finish
Additional Options
Standard
Q16
S1
Expanded
SC
Surface Finishing Certification
Tank Spud Included with Shipment
Standard
★
★
0.006-in. (150 m) Diaphragm Thickness
Complete the 3051SAL model number by specifying options as needed:
ERS Transmitter Options, see page 51
Liquid Level Transmitter Options, see page 55
(1) Clamp and Ethylene Propylene o-ring (conforms to 3-A standard 74 and USP class VI) supplied.
(2) Diaphragm brazed and TIG-welded to extension.
(3) Require Option code R6 (Electropolishing).
67
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Specifications
PERFORMANCE SPECIFICATIONS
For zero-based spans, reference conditions, silicone oil fill, glass-filled PTFE o-rings, SST materials, Coplanar flange (3051SMV, 3051S_C) or
1/2 in.- 14 NPT (3051S_T) process connections, digital trim values set to equal range points.
Conformance to Specification (±3 (Sigma))
Technology leadership, advanced manufacturing techniques, and statistical process control ensure measurement specification conformance to
±3or better.
Reference Accuracy
Stated reference accuracy equations include terminal based linearity, hysteresis, and repeatability.
For FOUNDATION fieldbus and wireless devices, use calibrated range in place of span.
Transmitter with Coplanar Sensor Module (Single Variable)
Differential Pressure (3051S_CD)
Gage Pressure (3051S_CG, 3051SAM_ _G(1))
Ultra
Classic
Ultra for Flow(2)
Ranges 2 - 4
±0.025% of span;
For spans less than 10:1,
±[0.005 + 0.0035(URL / Span)]% of
span
±0.055% of span;
For spans less than 10:1,
±[0.015 + 0.005(URL / Span)]% of span
±0.04% of reading up to 8:1 DP
turndown from URL;
±[0.04 + 0.0023(URL /
Reading)]% of reading to 200:1
DP turndown from URL
Range 5
±0.05% of span;
For spans less than 10:1,
±[0.005 + 0.0045(URL / Span)]% of
span
±0.065% of span;
For spans less than 10:1,
±[0.015 + 0.005(URL / Span)]% of span
Not Available
Range 1
±0.09% of span;
For spans less than 15:1,
±[0.015 + 0.005(URL / Span)]% of span
±0.10% of span;
For spans less than 15:1,
±[0.025 + 0.005(URL / Span)]% of span
Not Available
Range 0
±0.09% of span;
For spans less than 2:1,
±0.045% of URL
±0.10% of span;
For spans less than 2:1,
±0.05% of URL
Not Available
Absolute Pressure (3051S_CA, 3051SAM_ _A(1))
Ultra
Classic
Ranges 1 - 4
±0.025% of span;
For spans less than 10:1,
±[0.004(URL / Span)]% of span
±0.055% of span;
For spans less than 10:1,
±[0.0065(URL / Span)]% of span
Range 0
±0.075% of span;
For spans less than 5:1,
±[0.025 + 0.01(URL / Span)]% of span
±0.075% of span;
For spans less than 5:1,
±[0.025 + 0.01(URL / Span)]% of span
(1) Specifications are for each gage / absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
(2) Ultra for Flow is only available for 3051S_CD ranges 2-3 and 3051SMV DP ranges 2-3. For calibrated spans from 1:1 to 2:1 of URL, add ±0.005% of span
analog output error.
68
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Transmitter with In-Line Sensor Module
Absolute Pressure (3051S_TA, 3051SAM_ _E(1))
Gage Pressure (3051S_TG, 3051SAM_ _T(1))
Ranges 1 - 4
Range 5
Ultra
±0.025% of span
For spans less than 10:1,
±[0.004(URL / Span)]% of span
±0.04% of span
Classic
±0.055% of span
For spans less than 10:1,
±[0.0065(URL / Span)]% of span
±0.065% of span
(1) Specifications are for each gage / absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
Transmitter with MultiVariable Sensor Module
Differential Pressure and Static Pressure (3051SMV_ _1 or 2)
Classic MV
Ultra for Flow(1)
DP Ranges 2-3
±0.04% of span
For spans less than 10:1,
±[0.01 + 0.004(URL / Span)]% of span
±0.04% of reading up to 8:1 DP turndown from URL
±[0.04 + 0.0023(URL / Reading)]% of reading to 200:1 DP turndown from
URL
DP Range 1
±0.10% of span
For spans less than 15:1,
±[0.025 + 0.005(URL / Span)]% of span
Not Available
AP & GP Ranges
3-4
±0.055% of span
For spans less than 10:1,
±[0.0065(URL / Span)]% of span
±0.025% of span
For spans less than 10:1,
±[0.004(URL / Span)]% of span
(1) Ultra for Flow is only available for 3051SMV DP ranges 2-3. For calibrated DP spans from 1:1 to 2:1 of URL, add ±0.005% of span analog output error.
Liquid Level Transmitter
3051SAL
Ultra
±0.065% of span
For spans less than 10:1,
±[0.015 + 0.005(URL / Span)]% of span
Classic
±0.065% of span
For spans less than 10:1,
±[0.015 + 0.005(URL / Span)]% of span
Process Temperature RTD Interface(1)
Process Temperature (3051SMV_ _1 or 3)
±0.67 °F (0.37 °C)
(1) Specifications for process temperature are for the transmitter portion only. The transmitter is compatible with any Pt 100 (100 ohm platinum) RTD. Examples
of compatible RTDs include Rosemount series 68 and 78 RTD Temperature Sensors.
DP Reference Accuracy of 3051S ERS System(1)
2 Coplanar Gage Transmitters (3051SAM_ _G)
Ultra
Ranges 2-4
±0.035% of DP span
Range 5
±0.071% of DP span
2 Coplanar Absolute Transmitters (3051SAM_ _A)
Ultra
Ranges 1-4
±0.035% of DP span
2 In-Line Gage Transmitters (3051SAM_ _T)
2 In-Line Absolute Transmitters (3051SAM_ _E)
Ultra
Ranges 1-4
±0.035% of DP span
2 Liquid Level Transmitters (3051SAL)
Ultra
Ranges 1-4
±0.092% of DP span
Classic
±0.078% of DP span
±0.092% of DP span
Classic
±0.078% of DP span
Classic
±0.078% of DP span
Classic
±0.092% of DP span
(1) Reference Accuracy specifications for ERS system assume that the configuration contains two transmitters with identical sensor ranges, each transmitter
sensor is calibrated 0 – URL, and the DP Span = 10% of transmitter URL.
69
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Transmitter Total Performance
Total performance is based on combined errors of reference accuracy, ambient temperature effect, and line
pressure effect.
Models
3051S_CD
3051S_CG
3051S_CA
3051S_T
3051SMV(2)
3051SAM_ _G(3)
3051SAM_ _A(3)
3051SAM_ _T(3)
3051SAM_ _E(3)
3051SAL
Ranges 2-3
Ranges 2-5
Ranges 2-4
Ranges 2-4
DP Ranges 2-3
Ranges 2-5
Ranges 2-4
Ranges 2-4
Ranges 2-4
Ultra
Classic and Classic MV
Ultra for Flow(1)
±0.1% of span
±0.15% of span
±0.15% of reading
For ±50 °F (28 °C) temperature
changes; 0-100% relative
humidity, up to 740 psi (51 bar)
line pressure (DP only) from 1:1
to 5:1 rangedown
For ±50 F (28 °C) temperature
changes, 0-100% relative
humidity, up to 740 psi (51 bar)
line pressure (DP only) from 1:1
to 5:1 rangedown
For ±50 °F (28 °C) temperature
changes, 0-100% relative
humidity, up to 740 psi (51 bar)
line pressure (DP only) over 8:1
DP turndown from URL
Use Instrument Toolkit or the QZ Option to quantify the total performance of a remote seal assembly
under operating conditions.
(1) Ultra for Flow is only available for 3051S_CD Ranges 2-3 and 3051SMV DP Ranges 2-3.
(2) For 3051SMV, Transmitter Total Performance specification applies to differential pressure measurement only.
(3) Specifications are for each gage / absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
MultiVariable Flow Performance(1)
Mass, Energy, Actual Volumetric, and Totalized Flow Reference Accuracy
Models
Ultra for Flow
Classic MV
±0.65% of Flow Rate over a 14:1 flow range
(200:1 DP range)
±0.70% of Flow Rate over 8:1 flow range
(64:1 DP range)
Not Available
±0.90% of Flow Rate over 8:1 flow range
(64:1 DP range)
±0.80% of flow rate at 14:1 flow turndown
±1.15% of flow rate at 8:1 flow turndown
3051SMV(2)
DP Ranges 2-3
DP Range 1
Annubar Flowmeter (3051SFA)
Ranges 2-3
Compact Conditioning Orifice Flowmeter (3051SFC_C)
Ranges 2-3
 = 0.4 ±0.75% of flow rate at 14:1 flow turndown
±1.10% of flow rate at 8:1 flow turndown
 = 0.65 ±1.15% of flow rate at 14:1 flow turndown
±1.45% of flow rate at 8:1 flow turndown
Compact Orifice Flowmeter(3) (3051SFC_P)
Ranges 2-3
 = 0.4 ±1.30% of flow rate at 14:1 flow turndown
±1.45% of flow rate at 8:1 flow turndown
 = 0.65 ±1.30% of flow rate at 14:1 flow turndown
±1.45% of flow rate at 8:1 flow turndown
Integral Orifice Flowmeter (3051SFP)
Ranges 2-3
 < 0.1 ±2.50% of flow rate at 14:1 flow turndown
±2.65% of flow rate at 8:1 flow turndown
0.1 <  < 0.2 ±1.40% of flow rate at 14:1 flow turndown
±1.60% of flow rate at 8:1 flow turndown
0.2 <  < 0.6 ±0.95% of flow rate at 14:1 flow turndown
±1.25% of flow rate at 8:1 flow turndown
0.6 <  < 0.8 ±1.60% of flow rate at 14:1 flow turndown
±1.80% of flow rate at 8:1 flow turndown
(1) Flow performance specifications assume device is configured for full compensation of static pressure, process temperature, density, viscosity, gas
expansion, discharge coefficient, and thermal correction variances over a specified operating range.
(2) Uncalibrated differential producer (0.2 < beta < 0.6 Orifice) installed per ASME MFC 3M or ISO 5167-1. Uncertainties for discharge coefficient, producer
bore, tube diameter, and gas expansion factor as defined in ASME MFC 3M or ISO 5167-1. Reference accuracy does not include RTD sensor accuracy.
(3) For line sizes less than 2-in. (50mm) or greater than 8 in. (200 mm), see the Rosemount DP Flowmeters and Primary Elements Product Data Sheet
(document number 00813-0100-4485).
70
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Uncompensated Flow Performance
Flow performance specifications assume the device only uses DP readings without pressure and temperature compensation.
Models
Ultra
Classic
Ultra for Flow
±1.4% of flow rate at 8:1 flow
turndown
±0.80% of flow rate at 14:1 flow
turndown
Annubar Flowmeter (3051SFA)
Ranges 2-3
±0.95% of flow rate at 8:1 flow
turndown
Compact Conditioning Orifice Flowmeter (3051SFC_C)
Ranges 2-3
 = 0.4
±0.90% of flow rate at 8:1 flow
turndown
±1.40% of flow rate at 8:1 flow
turndown
±0.75% of flow rate at 14:1 flow
turndown
 = 0.65
±1.25% of flow rate at 8:1 flow
turndown
±1.65% of flow rate at 8:1 flow
turndown
±1.15% of flow rate at 14:1 flow
turndown
Compact Orifice Flowmeter(1) (3051SFC_P)
Ranges 2-3
 = 0.4
±1.35% of flow rate at 8:1 flow
turndown
±1.80% of flow rate at 8:1 flow
turndown
±1.30% of flow rate at 14:1 flow
turndown
 = 0.65
±1.35% of flow rate at 8:1 flow
turndown
±1.80% of flow rate at 8:1 flow
turndown
±1.30% of flow rate at 14:1 flow
turndown
Integral Orifice Flowmeter (3051SFP)
Ranges 2-3
 < 0.1
±2.65% of flow rate at 8:1 flow
turndown
±2.70% of flow rate at 8:1 flow
turndown
±2.60% of flow rate at 14:1 flow
turndown
0.1 <  < 0.2
±1.45% of flow rate at 8:1 flow
turndown
±1.80% of flow rate at 8:1 flow
turndown
±1.40% of flow rate at 14:1 flow
turndown
0.2 <  < 0.6
±1.05% of flow rate at 8:1 flow
turndown
±1.50% of flow rate at 8:1 flow
turndown
±0.95% of flow rate at 14:1 flow
turndown
0.6 <  < 0.8
±1.70% of flow rate at 8:1 flow
turndown
±2.00% of flow rate at 8:1 flow
turndown
±1.60% of flow rate at 14:1 flow
turndown
(1) For line sizes less than 2-in. (50mm) or greater than 8 in. (200 mm), see the Rosemount DP Flowmeters and Primary Elements Product Data Sheet
(document number 00813-0100-4485).
Long Term Stability
Pressure
Models
3051S_CD
3051S_CG
3051S_CA
3051S_T
3051SMV
3051SF
3051SAM_ _G(2)
3051SAM_ _A(2)
3051SAM_ _T(2)
3051SAM_ _E(2)
Ranges 2-5
Ranges 2-5
Ranges 1-4
Ranges 1-5
DP Ranges 2-5
AP & GP Ranges 3-4
Ranges 2-5
Ranges 1-4
Ranges 1-5
Ranges 1-5
Ultra and Ultra for Flow(1)
Classic and Classic MV
±0.20% of URL for 10 years; for ±50 °F (28 °C)
temperature changes, up to 1000 psi (68,9 bar)
line pressure
±0.125% of URL for 5 years; for ±50 °F
(28 °C) temperature changes, up to 1000
psi (68,9 bar) line pressure
(1) Ultra is only available for 3051S, 3051SMV_ _3 and 4, 3051SF_3, 4, 7, and D. Ultra for Flow is only available on 3051S_CD ranges 2-3, 3051SMV DP
ranges 2-3, and 3051SF DP ranges 2-3.
(2) Specifications are for each gage / absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
Process Temperature(1)
Models
3051SMV
3051SF
RTD Interface(1)
The greater of ±0.185 °F (0.103 °C) or 0.1% of reading per year (excludes RTD sensor stability).
(1) Specifications for process temperature are for the transmitter portion only. The transmitter is compatible with any Pt 100 (100 ohm platinum) RTD. Examples
of compatible RTDs include the Rosemount Series 68 and 78 RTD Temperature Sensors.
71
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Warranty(1)
Models
All 3051S Products
Ultra and Ultra for Flow
Classic and Classic MV
(2)
(1)
1-year limited warranty(3)
12-year limited warranty
(1) Warranty details can be found in Emerson Process Management Terms & Conditions of Sale, Document 63445, Rev G (10/06).
(2) Rosemount Ultra and Ultra for Flow transmitters have a limited warranty of twelve (12) years from date of shipment. All other provisions of Emerson Process
Management standard limited warranty remain the same.
(3) Goods are warranted for twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by seller, whichever period
expires first.
Dynamic Performance
Total Time Response at 75 °F (24 °C), includes dead time(1)(2)
3051S_C
3051SF_D
3051S_T
DP Ranges 2-5: 100 ms
Range 1: 255 ms
Range 0: 700 ms
100 ms
3051SMV_ _1 or 2
3051SF_1, 2, 5, or 6
3051SMV_ _3 or 4
3051SF_3, 4, or 7
DP Range 1: 310 ms
DP Range 2: 170 ms
DP Range 3: 155 ms
AP & GP: 240 ms
DP Ranges 2-5: 145 ms
DP Range 1: 300 ms
DP Range 0: 745 ms
ERS System (3051SAM)
360 ms
(1) For FOUNDATION fieldbus (output code F), add 52 ms to stated values (not including segment macro-cycle).
For option code DA2, add 45 ms (nominal) to stated values.
(2) Consult Instrument Toolkit for transmitter configurations with remote seals including 3051SAL
Dead Time(1)
3051S_C
3051S_T
3051SF_D
3051SAL_C
45 ms (nominal)
3051SMV
3051SF_1-7
DP: 100 ms
AP & GP: 140 ms
RTD Interface: 1 s
ERS System (includes
3051SAM, 3051SAL_P,
and 3051SAL_S models
220 ms
(1) For option code DA2, dead time is 90 milliseconds (nominal).
Update Rate(1)
3051S_C or T
3051SF_D
3051SAL_C
ERS System (includes
3051SAM, 3051SAL_P, and
3051SAL_S models
3051SMV
3051SF_1-7
22 updates per sec. DP: 22 updates per sec.
AP & GP: 11 updates per sec.
RTD Interface: 1 update per sec.
Calculated Variables:
Mass / Volumetric Flow Rate: 22 updates per sec.
Energy Flow Rate: 22 updates per sec.
Totalized Flow: 1 update per sec.
(1) Does not apply to Wireless (output code X). See"IEC 62591 (WirelessHART)" on page 80 for wireless update rate.
72
11 updates per sec.
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Ambient Temperature Effect
Transmitter with Coplanar Sensor Module (Single Variable)
Differential Pressure: (3051S_CD, 3051SMV_ _3 or 4)
Gage Pressure: (3051S_CG, 3051SAM_ _G(1))
Ultra
per 50 °F (28 °C)
Ranges 2 - 5(3)
±(0.009% URL + 0.025% span)
from 1:1 to 10:1;
±(0.018% URL + 0.08% span)
from >10:1 to 200:1
Range 0 ±(0.25% URL + 0.05% span)
from 1:1 to 30:1
Range 1 ±(0.1% URL + 0.25% span)
from 1:1 to 50:1
Absolute Pressure: (3051S_CA, 3051SAM_ _A(1))
Ranges 2-4
Range 0
Range 1
Classic
per 50 °F (28 °C)
Ultra for Flow(2)
-40 to 185 °F (-40 to 85 °C)
±(0.0125% URL +0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 100:1
±(0.25% URL + 0.05% span)
from 1:1 to 30:1
±(0.1% URL + 0.25% span)
from 1:1 to 50:1
±0.13% of reading up to 8:1 DP turndown
from URL;
±[0.13 + 0.0187(URL/Reading)]% of
reading to 100:1 DP turndown from URL
Not Available
Ultra
per 50 °F (28 °C)
Classic
per 50 °F (28 °C)
±(0.0125% URL + 0.0625%
span) from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 200:1
±(0.1% URL + 0.25% span)
from 1:1 to 30:1
±(0.0125% URL + 0.0625%
span) from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 100:1
±(0.0125% URL + 0.0625% span) from 1:1
to 5:1;
±(0.025% URL + 0.125% span) from >5:1
to 100:1
±(0.1% URL + 0.25% span) from 1:1 to
30:1
±(0.0125% URL + 0.0625% span) from 1:1
to 5:1;
±(0.025% URL + 0.125% span) from >5:1
to 100:1
Not Available
(1) Specifications are for each gage / absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
(2) Ultra for Flow is only available for 3051S_CD Ranges 2-3 and 3051SMV DP Ranges 2-3.
(3) Use Classic specification for 3051SMV DP Range 5 Ultra and 3051S_CD Range 5 Ultra.
Transmitter with In-Line Sensor Module
Absolute Pressure: (3051S_TA, 3051SAM_ _E(1))
Gage Pressure: (3051S_TG, 3051SAM_ _T(1))
Ranges 2-4
Range 5
Range 1
Ultra
per 50 °F (28 °C)
Classic
per 50 °F (28 °C)
±(0.009% URL + 0.025% span)
from 1:1 to 10:1;
±(0.018% URL + 0.08% span)
from >10:1 to 100:1
±(0.05% URL + 0.075% span)
from 1:1 to 10:1
±(0.0125% URL + 0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 100:1
±(0.0125% URL + 0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 100:1
±(0.05% URL + 0.075% span)
from 1:1 to 10:1
±(0.0125% URL + 0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span)
from >5:1 to 100:1
(1) Specifications are for each gage / absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
73
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Ambient Temperature Effect (continued)
Transmitter with MultiVariable Sensor Module
Differential Pressure and Static Pressure (3051SMV_ _1 or 2)
Models
DP Ranges 2-3
DP Range 1
Classic MV
Per 50 °F (28 °C)
Ultra for Flow
-40 to 185 °F (-40 to 85 °C)
±(0.0125% URL + 0.0625% span)
from 1:1 to 5:1;
±(0.025% URL + 0.125% span) for >5:1
±0.13 reading up to 8:1 DP turndown
from URL;
±[0.13 + 0.0187(URL/Reading)]%
reading to 100:1 DP turndown from URL
Not available
±(0.1% URL + 0.25% span)
from 1:1 to 50:1
±(0.0125% URL + 0.0625% span)
from 1:1 to 10:1;
±(0.025% URL + 0.125% span) for >10:1
AP & GP
±(0.009% URL + 0.025% span)
from 1:1 to 10:1;
±(0.018% URL + 0.08% span) for >10:1
Liquid Level Transmitter
3051SAL
Ultra
See Instrument Toolkit
Classic
See Instrument Toolkit
Process Temperature RTD Interface(1)
Process Temperature (3051SMV_ _1 or 3)
(1)
Classic MV
Per 50 °F (28 °C)
Ultra for Flow
-40 to 185 °F (-40 to 85 °C)
±0.39 °F (0,216 °C) per 50 °F (28 °C)
±0.39 °F (0,216 °C) per 50 °F (28 °C)
(1) Specifications for process temperature are for the transmitter portion only. The transmitter is compatible with any Pt 100 (100 ohm platinum) RTD. Examples
of compatible RTDs include Rosemount series 68 and 78 RTD Temperature Sensors.
Line Pressure Effect(1)
3051S_CD
3051SMV (DP Measurement Only)
Zero Error(2)
Range 2-3
Range 0
Range 1
Span Error(3)
Range 2-3
Range 0
Range 1
Ultra and Ultra for Flow
Classic and Classic MV
± 0.025% URL per 1000 psi (69 bar)
± 0.125% URL per 100 psi (6,9 bar)
± 0.25% URL per 1000 psi (69 bar)
± 0.05% URL per 1000 psi (69 bar)
± 0.125% URL per 100 psi (6,9 bar)
± 0.25% URL per 1000 psi (69 bar)
± 0.1% of reading per 1000 psi (69 bar)
± 0.15% of reading per 100 psi (6,9 bar)
± 0.4% of reading per 1000 psi (69 bar)
± 0.1% of reading per 1000 psi (69 bar)
± 0.15% of reading per 100 psi (6,9 bar)
± 0.4% of reading per 1000 psi (69 bar)
(1) For zero error specifications for line pressures above 2000 psi (137,9 bar) or line pressure effect specifications for DP Ranges 4-5, see the 3051SMV
Reference Manual (document number 00809-0100-4803) or 3051S Reference Manual (document number 00809-0100-4801).
(2) Zero error can be removed by performing a zero trim at line pressure.
(3) Specifications for option code P0 are 2 times those shown above.
74
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Mounting Position Effects
Models
Ultra, Ultra for Flow, Classic and Classic MV
3051S_CD or CG
3051SMV_ _ 3 or 4
3051SF_3, 4, 7, or D
3051SAM_ _G
3051S_CA
3051S_T
3051SAM_ _A, T, or E
3051SMV_ _ 1 or 2
DP Sensor:
3051SF_1, 2, 5, or 6
GP/AP
Sensor:
3051SAL
Zero shifts up to ±1.25 inH2O (3,11 mbar), which can be zeroed
Span: no effect
Zero shifts to ±2.5 inH2O (6,22 mbar), which can be zeroed
Span: no effect
Zero shifts up to ±1.25 inH2O (3,11 mbar), which can be zeroed
Span: no effect
Zero shifts to ±2.5 inH2O (6,22 mbar), which can be zeroed
Span: no effect
With liquid level diaphragm in vertical plane, zero shift of up to ±1 inH2O (2,5 mbar). With diaphragm in
vertical plane, zero shift of up to ±5 inH2O (12,4 mbar) plus extension length on extended units. All
zero shifts can be zeroed.
Span: no effect
Vibration Effect
Less than ±0.1% of URL when tested per the requirements of
IEC60770-1 field or pipeline with high vibration level (10-60 Hz
0.21 mm displacement peak amplitude / 60-2000 Hz 3g).
For Housing Style codes 1J, 1K, 1L, 2J, and 2M:
Less than ±0.1% of URL when tested per the requirements of
IEC60770-1 field with general application or pipeline with low
vibration level (10-60 Hz 0.15 mm displacement peak amplitude /
60-500 Hz 2g).
Power Supply Effect
Less than ±0.005% of calibrated span per volt change in voltage at
the transmitter terminals
Electromagnetic Compatibility (EMC)
Meets all relevant requirements of EN 61326 and NAMUR NE-21.(1)(2)
(1) NAMUR NE-21 does not apply to wireless output code X or ERS
configurations.
(2) 3051SMV and 3051SF_1, 2, 3, 4, 5, 6, 7 requires shielded cable for both
temperature and loop wiring.
Transient Protection (Option T1)
Tested in accordance with IEEE C62.41.2-2002,
Location Category B
6 kV crest (0.5 s - 100 kHz)
3 kA crest (8 × 20 microseconds)
6 kV crest (1.2 × 50 microseconds)
75
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
FUNCTIONAL SPECIFICATIONS
Range and Sensor Limits
Transmitter with Coplanar Sensor Module (Single Variable)
DP Sensor(1)
(3051S_CD, 3051SMV_ _3, 4, or D
3051SF_3, 4, or 7, 3051SAL_CD)
GP Sensor
(3051S_CG, 3051SAM_ _G, 3051SAL_ _G)
AP Sensor(2)
(3051S_CA, 3051SAM_ _A, 3051SAL_ _A)
Range
Lower (LRL)(3)
Upper (URL)
Lower (LRL)(4)
Upper (URL)
Lower (LRL)
Upper (URL)
0
-3 inH2O
(-7,5 mbar)
-25 inH2O
(-62,3 mbar)
-250 inH2O
(-0,62 bar)
-1000 inH2O
(-2,49 bar)
-300 psi
(-20,7 bar)
-2000 psi
(-137,9 bar)
3 inH2O
(7,5 mbar)
25 inH2O
(62,3 mbar)
250 inH2O
(0,62 bar)
1000 inH2O
(2,49 bar)
300 psi
(20,7 bar)
2000 psi
(137,9 bar)
N/A
N/A
-25 inH2O
(-62,3 mbar)
-250 inH2O
(-0,62 bar)
-393 inH2O
(-979 mbar)
-14.2 psig
(-979 mbar)
-14.2 psig
(-979 mbar)
25 inH2O
(62,3 mbar)
250 inH2O
(0,62 bar)
1000 inH2O
(2,49 bar)
300 psi
(20,7 bar)
2000 psi
(137,9 bar)
0 psia
(0 bar)
0 psia
(0 bar)
0 psia
(0 bar)
0 psia
(0 bar)
0 psia
(0 bar)
N/A
5 psia
(0,34 bar)
30 psia
(2,07 bar)
150 psia
(10,34 bar)
800 psia
(55,16 bar)
4000 psia
(275,8 bar)
N/A
1
2
3
4
5
(1) 3051SF flowmeters only available with ranges 1, 2, and 3.
(2) Range 0 is not available for 3051SAL_ _A.
(3) The Lower Range Limit (LRL) is 0 inH20 (0 mbar) for Ultra for Flow performance class and 3051SF flowmeters.
(4) Assumes atmospheric pressure of 14.7 psig (1 bar).
Transmitter with In-Line Sensor Module
GP Sensor
(3051S_TG, 3051SAM_ _T, 3051SAL_ _T)
AP Sensor
(3051S_TA, 3051SAM_ _E, 3051SAL_ _E)
Range
Lower (LRL)(1)
Upper (URL)
Lower (LRL)
Upper (URL)
1
2
3
4
5
-14.7 psig (-1,01 bar)
-14.7 psig (-1,01 bar)
-14.7 psig (-1,01 bar)
-14.7 psig (-1,01 bar)
-14.7 psig (-1,01 bar)
30 psig (2,07 bar)
150 psig (10,34 bar)
800 psig (55,16 bar)
4000 psig (275,8 bar)
10000 psig (689,5 bar)
0 psia (0 bar)
0 psia (0 bar)
0 psia (0 bar)
0 psia (0 bar)
0 psia (0 bar)
30 psia (2,07 bar)
150 psia (10,34 bar)
800 psia (55,16 bar)
4000 psia (275,8 bar)
10000 psia (689,5 bar)
(1) Assumes atmospheric pressure of 14.7 psig (1 bar).
Transmitter with MultiVariable Sensor Module
(3051SMV_ _1, 3051SMV_ _2, 3051SF_1, 3051SF_2, 3051SF_5, and 3051SF_6)
DP Sensor
Range
Lower (LRL)(1)
Upper (URL)
1
2
3
-25.0 inH2O (-62,3 mbar)
-250.0 inH2O (-0,62 bar)
-1000.0 inH2O (-2,49 bar)
25.0 inH2O (62,3 mbar)
250.0 inH2O (0,62 bar)
1000.0 inH2O (2,49 bar)
(1) Lower (LRL) is 0 inH2O (0 mbar) for Ultra for Flow and 3051SF_ Flowmeters.
Static Pressure Sensor (GP/AP)
Lower (LRL)
Upper (URL)(1)
GP
: -14.2 psig (0,98 bar)
AP: 0.5 psia (34,5 mbar)
GP(2)(3): -14.2 psig (0,98 bar)
AP: 0.5 psia (34,5 mbar)
GP: 800 psig (55,16 bar)
AP: 800 psia (55,16 bar)
GP: 3626 psig (250 bar)
AP: 3626 psia (250 bar)
Range
3
4
(2)(3)
(1) For SP Range 4 with DP Range 1, the URL is 2000 psi (137,9 bar).
(2) Inert Fill: Minimum pressure = 1.5 psia (0,10 bar) or -13.2 psig (-0,91 bar).
(3) Assumes atmospheric pressure of 14.7 psig (1 bar).
76
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Process Temperature RTD Interface
(3051SMV_ _1 or 3, 3051SF_1, 3, 5 or 7)(1)
Lower (LRL)
Upper (URL)
-328 °F (-200 °C)
1562 °F (850 °C)
(1) Transmitter is compatible with any Pt 100 RTD sensor. Examples of compatible RTDs include Rosemount Series 68 and 78 RTD Temperature Sensors.
Minimum Span Limits
Transmitter with Coplanar Sensor Module (Single Variable)
DP Sensor(1)
(3051S_CD, 3051SMV_ _3 or 4,
GP Sensor
AP Sensor
3051SF_D, 3, 4 or 7, 3051SAL_ _CD) (3051S_CG, 3051SAM_ _G, 3051SAL_ _G(2)) (3051S_CA, 3051SAM_ _A, 3051SAL_ _A(2))
Range
0
1
2
3
4
5
Ultra &
Ultra for Flow
Classic
Ultra
Classic
Ultra
Classic
0.1 inH2O
(0,25 mbar)
0.5 inH2O
(1,24 mbar)
1.3 inH2O
(3,23 mbar)
5.0 inH2O
(12,4 mbar)
1.5 psi
(103,4 mbar)
10.0 psi
(689,5 mbar)
0.1 inH2O
(0,25 mbar)
0.5 inH2O
(1,24 mbar)
2.5 inH2O
(6,23 mbar)
10.0 inH2O
(24,9 mbar)
3.0 psi
(206,8 mbar)
20.0 psi
(1,38 bar)
N/A
N/A
0.5 inH2O
(1,24 mbar)
1.3 inH2O
(3,23 mbar)
5.0 inH2O
(12,4 mbar)
1.5 psig
(103,4 mbar)
10.0 psig
(689,5 mbar)
0.5 inH2O
(1,24 mbar)
2.5 inH2O
(6,23 mbar)
10.0 inH2O
(24,9 mbar)
3.0 psig
(206,8 mbar)
20.0 psig
(1,38 bar)
0.167 psia
(11,5 mbar)
0.3 psia
(20,7 mbar)
0.75 psia
(51,7 mbar)
4 psia
(275,8 mbar)
20 psia
(275,8 mbar)
N/A
0.167 psia
(11,5 mbar)
0.3 psia
(20,7 mbar)
1.5 psia
(103,4 mbar)
8 psia
(0,55 bar)
40 psia
(2,76 bar)
N/A
(1) 3051SF flowmeters only available with ranges 1, 2, and 3.
(2) Specifications are for each gage / absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
Transmitter with In-Line Sensor Module
GP Sensor
(3051S_TG, 3051SAM_ _T, 3051SAL_ _T(1))
AP Sensor
(3051S_TA, 3051SAM_ _E, 3051SAL_ _E(1))
Range
Ultra
Classic
Ultra
Classic
1
2
3
4
5
0.3 psig (20,7 mbar)
0.75 psig (51,7 mbar)
4 psig (275,8 mbar)
20 psig (1,58 bar)
1000 psig (68,9 bar)
0.3 psig (20,7 mbar)
1.5 psig (103,4 bar)
8 psig (0,55 bar)
40 psig (2,76 bar)
2000 psig (137,9 bar)
0.3 psia (20,7 mbar)
0.75 psia (51,7 mbar)
4 psia (275,8 mbar)
20 psia (1,58 bar)
1000 psia (68,9 bar)
0.3 psia (20,7 mbar)
1.5 psia (103,4 bar)
8 psia (0,55 bar)
40 psia (2,76 bar)
2000 psia (137,9 bar)
(1) Specifications are for each gage / absolute pressure sensor of the ERS system and are not reflective of the DP calculation.
Transmitter with MultiVariable Sensor Module
(3051SMV_ _1 or 2, 3051SF_1, 2, 5, or 6)
DP Sensor
Range
Ultra for Flow
Classic MV
1
2
3
0.5 inH2O (1,24 mbar)
1.3 inH2O (3,23 mbar)
5.0 inH2O (12,4 mbar)
0.5 inH2O (1,24 mbar)
2.5 inH2O (6,23 mbar)
10.0 inH2O (24,9 mbar)
Range
Ultra for Flow
Classic MV
3
4
4.0 psi (276 mbar)
18.13 psi (1,25 bar)
8.0 psi (522 mbar)
36.26 psi (2,50 bar)
Static Pressure Sensor (GP/AP)
77
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Process Temperature RTD Interface
(3051SMV_ _1 or 3, 3051SF_1, 3, 5 or 7)
Minimum Span = 50 °F (28 °C)
DP Span Considerations for Electronic Remote Sensor Applications
It is recommended that the DP rangedown (Operating Pressure/DP Span) for ERS applications not exceed 100:1. Consult with your Emerson
Process Management sales representative when considering a 3051S ERS System for applications beyond 100:1 rangedown.
Service
3051S, 3051SMV_P, 3051SAM, and 3051SF_5, 6, 7, or D (Direct Process Variable Output):
Liquid, gas, and vapor applications
3051SAL
Liquid level applications
3051SMV_M and 3051SF_1, 2, 3, or 4 (Mass and Energy Flow Output):
Some fluid types are only supported by certain measurement types
Fluid Compatibility with Pressure and Temperature Compensation
Ordering
Code
1
2
3
4
Measurement Type
DP / P/ T (Full Compensation)
DP / P
DP / T
DP only
• Available
Fluid Types
— Not available
Liquids
Saturated Steam
Superheated Steam
Gas and Natural Gas
•
•
•
•
•
•
•
•
•
•
—
—
•
•
—
—
HART / 4–20 mA
Zero and Span Adjustment
Output
Two-wire 4–20 mA is user-selectable for linear or square root
output. Digital process variable superimposed on 4–20 mA
signal, available to any host that conforms to the HART
protocol.
3051S and 3051SF_D
Maximum Loop Resistance = 43.5 * (Power Supply Voltage – 10.5)
1387
Load (Ohms)
Zero and span values can be set anywhere within the range.
Span must be greater than or equal to the minimum span.
Power Supply
1000
500
0
External power supply required.
•
3051S and 3051SF_D: 10.5 to 42.4 Vdc with no load
•
3051S and 3051SF_D with Advanced HART Diagnostics
Suite: 12 to 42.4 Vdc with no load
•
3051SMV and 3051SF_1-7: 12 to 42.4 Vdc with no load
Load Limitations
Maximum loop resistance is determined by the voltage level of
the external power supply, as described by:
Operating
Region
10.5
20
30
Voltage (Vdc)
42.4
The Field Communicator requires a minimum
loop resistance of 250 for communication.
3051SMV and 3051SF_1-7
3051S and 3051SF_D with HART Diagnostics
(option code DA2)
Maximum Loop Resistance = 43.5 * (Power Supply Voltage – 12.0)
Load (Ohms)
1322
1000
500
Operating
Region
0
12.0
20
30
Voltage (Vdc)
42.4
The Field Communicator requires a minimum
loop resistance of 250 for communication.
78
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Transducer Block
3051S ERS System
If supply voltage ≤ 16.74 Vdc:
Maximum Loop Resistance = 277 * (Power Supply Voltage – 16.0)
If supply voltage > 16.74 Vdc:
Maximum Loop Resistance = 43.5 * (Power Supply Voltage – 12.0)
Load (Ohms)
1322
LCD Block
• Configures the local display.
2 Analog Input Blocks
• Processes the measurements for input into other function
blocks. The output value is in engineering or custom units
and contains a status indicating measurement quality.
Operating
Region
206
0
• Contains actual sensor measurement data including the
sensor diagnostics and the ability to trim the pressure
sensor or recall factory defaults.
16 16.74
PID Block with Auto-tune
• Contains all logic to perform PID control in the field including
cascade and feedforward. Auto-tune capability allows for
superior tuning for optimized control performance.
42.4
Voltage (Vdc)
Backup Link Active Scheduler (LAS)
The Field Communicator requires a minimum
loop resistance of 250 for communication.
The transmitter can function as a Link Active Scheduler if the
current link master device fails or is removed from the
segment.
Advanced HART Diagnostics Suite
(Option Code DA2)
Statistical Process Monitoring (SPM) provides statistical data
(standard deviation, mean, coefficient of variation) that can be
used to detect process and process equipment anomalies,
including plugged impulse lines, air entrainment, pump
cavitation, furnace flame instability, distillation column flooding
and more. This diagnostic allows you to take preventative
measures before abnormal process situations result in
unscheduled downtime or rework.
Power Advisory diagnostic proactively detects and notifies you
of degraded electrical loop integrity before it can affect your
process operation. Example loop problems that can be
detected include water in the terminal compartment, corrosion
of terminals, improper grounding, and unstable power
supplies.
The Device Dashboard presents the diagnostics in a
graphical, task-based interface that provides single click
access to critical process/device information and descriptive
graphical troubleshooting.
Suite includes: Statistical Process Monitoring (SPM), Power
Advisory, Status Log, Variable Log, Advanced Process Alerts,
Service Alerts, and Time Stamp capability.
FOUNDATION fieldbus
Power Supply
External power supply required; transmitters operate on 9.0 to
32.0 Vdc transmitter terminal voltage.
Current Draw
17.5 mA for all configurations (including LCD display option)
FOUNDATION fieldbus Parameters
Schedule Entries
Links
Virtual Communications Relationships (VCR)
14 (max.)
30 (max.)
20 (max.)
Standard Function Blocks
Resource Block
• Contains hardware, electronics, and diagnostic information.
Software Upgrade in the Field
Software for the 3051S with FOUNDATION fieldbus is easy to
upgrade in the field using the FOUNDATION fieldbus Common
Device Software Download procedure.
PlantWeb Alerts
Enable the full power of the PlantWeb digital architecture by
diagnosing instrumentation issues, communicating advisory,
maintenance, and failure details, and recommending a
solution.
Advanced Control Function Block Suite
(Option Code A01)
Input Selector Block
• Selects between inputs and generates an output using
specific selection strategies such as minimum, maximum,
midpoint, average, or first “good.”
Arithmetic Block
• Provides pre-defined application-based equations including
flow with partial density compensation, electronic remote
sensors, hydrostatic tank gauging, ratio control and others.
Signal Characterizer Block
• Characterizes or approximates any function that defines an
input/output relationship by configuring up to twenty X, Y
coordinates. The block interpolates an output value for a
given input value using the curve defined by the configured
coordinates.
Integrator Block
• Compares the integrated or accumulated value from one or
two variables to pre-trip and trip limits and generates
discrete output signals when the limits are reached. This
block is useful for calculating total flow, total mass, or
volume over time.
Output Splitter Block
• Splits the output of one PID or other control block so that the
PID will control two valves or other actuators.
Control Selector Block
• Selects one of up to three inputs (highest, middle, or lowest)
that are normally connected to the outputs of PID or other
control function blocks.
79
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
IEC 62591 (WirelessHART)
Block
Execution Time
Output
Resource
Transducer
LCD Block
Analog Input 1, 2
PID with Auto-tune
Input Selector
Arithmetic
Signal Characterizer
Integrator
Output Splitter
Control Selector
20 milliseconds
35 milliseconds
20 milliseconds
20 milliseconds
20 milliseconds
20 milliseconds
20 milliseconds
20 milliseconds
IEC 62591 (WirelessHART), 2.4 GHz DSSS
Fully Compensated Mass Flow Block (Option Code H01)
Calculates fully compensated mass flow based on differential
pressure with external process pressure and temperature
measurements over the fieldbus segment. Configuration for
the mass flow calculation is easily accomplished using the
Rosemount Engineering Assistant 5.5.1.
FOUNDATION fieldbus Diagnostics Suite
(Option Code D01)
Statistical Process Monitoring (SPM) provides statistical data
(standard deviation and mean) that can be used to detect
process and process equipment anomalies, including plugged
impulse lines, air entrainment, pump cavitation, furnace flame
instability, distillation column flooding, and more. This
diagnostic allows you to take preventative measures before
abnormal process situations result in unscheduled downtime
or rework.
The Device Dashboard presents the diagnostics in a
graphical, task-based interface that provides single click
access to critical process/device information and descriptive
graphical troubleshooting.
Suite includes: Statistical Process Monitoring (SPM) and
Plugged Impulse Line Detection (PIL).
80
Radio Frequency Power Output from Antenna
External Antenna (WK option): Maximum of 10 mW
(10 dBm) EIRP
Extended Range, External Antenna (WM option): Maximum of
18 mW (12.5 dBm) EIRP
Local Display
The optional seven-digit LCD can display user-selectable
information such as primary variable in engineering units,
percent of range, sensor module temperature, and electronics
temperature. Display updates at the user-configured update
rate.
Update Rate
IEC 62591 (WirelessHART), user selectable 4 sec. to 60 min.
Power Module
Field replaceable, keyed connection eliminates the risk of
incorrect installation, Intrinsically Safe Lithium-thionyl chloride
Power Module with polybutadine terephthalate (PBT)
enclosure. Ten-year life at one minute update rate.(1)
(1) Reference conditions are 70 °F (21 °C), and routing data for three
additional network devices.
NOTE: Continuous exposure to ambient temperature limits of
-40 °F or 185 °F (-40 °C or 85 °C) may reduce specified life by less
than 20 percent.
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Overpressure Limits
Static Pressure Limits
Transmitters withstand the following limits without damage:
Coplanar Sensor Module (Single Variable)
DP(1)
& GP
DP Sensor(1)
Range
3051S_CA
3051SAM_ _A
0
1
2
3
4
5
750 psi (51,7 bar)
2000 psi (137,9 bar)
3626 psi (250,0 bar)
3626 psi (250,0 bar)
3626 psi (250,0 bar)
3626 psi (250,0 bar)
60 psia (4,13 bar)
750 psia (51,7 bar)
1500 psia (103,4 bar)
1600 psia (110,3 bar)
6000 psia (413,7 bar)
N/A
(1) The overpressure limit of a DP Sensor with the P9 option is 4500
psig (310,3 bar). The overpressure limit of a DP Sensor with the
P0 option is 6092 psig (420 bar).
Range
3051S_CD
3051SMV_ _3 or 4
3051SF_3, 4, 7, or D
0
1
2
3
4
5
0.5 psia to 750 psig (0,03 to 51,71 bar)
0.5 psia to 2000 psig (0,03 to 137,9 bar)
0.5 psia to 3626 psig (0,03 to 250 bar)
0.5 psia to 3626 psig (0,03 to 250 bar)
0.5 psia to 3626 psig (0,03 to 250 bar)
0.5 psia to 3626 psig (0,03 to 250 bar)
(1) The static pressure limit of a DP Sensor with the P9 option is 4500
psig (310,3 bar). The static pressure limit of a DP Sensor with the
P0 option is 6092 psig (420 bar).
Coplanar MultiVariable Sensor Module
(3051SMV_ _1 or 2, 3051SF_1, 2, 5, or 6)
In-Line Sensor Module
1
2
3
4
5
Operates within specifications between static line pressures of:
AP
3051S_CD, 3051S_CG
3051SMV_ _3 or 4
3051SF_3, 4, 7, or D
3051SAM_ _G
Range
Coplanar Sensor Module (Single Variable)
GP
AP
3051S_TG
3051SAM_ _T
3051S_TA
3051SAM_ _E
750 psi (51,7 bar)
1500 psi (103,4 bar)
1600 psi (110,3 bar)
6000 psi (413,7 bar)
15000 psi (1034,2 bar)
Operates within specifications between static line pressures of 0.5
psia (0,03 bar) and the values in the table below:
Static
Pressure
Range 3
GP/AP
Range 4
GP/AP
Coplanar MultiVariable Sensor Module
(3051SMV_ _1 or 2, 3051SF_1, 2, 5, or 6)
Differential Pressure
Range 1
Range 2
Range 3
800 psi
(57,91 bar)
2000 psi
(137,9 bar)
800 psi
(57,91 bar)
3626 psi
(250 bar)
800 psi
(57,91 bar)
3626 psi
(250 bar)
Burst Pressure Limits
Differential Pressure
Static
Pressure
Range 1
Range 2
Range 3
Range 3
GP/AP
Range 4
GP/AP
1600 psi
(110,3 bar)
2000 psi
(137,9 bar)
1600 psi
(110,3 bar)
3626 psi
(250 bar)
1600 psi
(110,3 bar)
3626 psi
(250 bar)
Liquid Level Transmitter (3051SAL)
Overpressure limit is dependent on the flange rating or sensor
rating (whichever is lower). Use Instrument Toolkit to ensure the
seal system meets all pressure and temperature limits.
Coplanar Sensor Module
(3051S_C, 3051SMV, 3051SF, 3051SAM_ _G or A)
10000 psig (689,5 bar)
In-Line Sensor Module
(3051S_T, 3051SAM_ _T or E)
• Ranges 1-4: 11000 psi (758,4 bar)
• Range 5: 26000 psi (1792,64 bar)
Temperature Limits
Ambient
-40 to 185 °F (-40 to 85 °C)
With LCD display(1): -40 to 175 °F (-40 to 80 °C)
With option code P0: -20 to 185 °F (-29 to 85 °C)
(1) LCD display may not be readable and LCD updates will be slower
at temperatures below -4 °F (-20 °C).
Storage
-50 to 185 °F (-46 to 85 °C)
With LCD display: -40 to 185 °F (-40 to 85 °C)
With Wireless Output: -40 to 185 °F (-40 to 85 °C)
81
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Process Temperature Limits
Humidity Limits
At atmospheric pressures and above:
0–100% relative humidity
Coplanar Sensor Module
3051S_C, 3051SMV, 3051SF, 3051SAM_ _G or A
Silicone Fill Sensor
(1)(2)
with Coplanar Flange
-40 to 250 °F (-40 to 121 °C)(3)
with Traditional Flange
-40 to 300 °F (-40 to 149 °C)(3)(4)
with Level Flange
-40 to 300 °F (-40 to 149 °C)(3)
with 305 Integral Manifold
-40 to 300 °F (-40 to 149 °C)(3)(4)
Sensor(1)(5)
-40 to 185 °F (-40 to 85 °C)(6) (7)
Inert Fill
In-Line Sensor Module
3051S_T, 3051SAM_ _T or E
Silicone Fill Sensor(1)
Inert Fill Sensor
(1)
Turn-On Time(1)
When power is applied to the transmitter during startup,
performance will be within specifications per the time period
described below:
Transmitter
Turn-On Time (Typical)
3051S, 3051SF_D, 3051SAL_ _C
Diagnostics
3051SMV, 3051SF_1-7
3051S ERS System
2 seconds
5 seconds
5 seconds
6 seconds
(1) Does not apply to wireless option code X.
-40 to 250 °F (-40 to 121 °C)(3)
Volumetric Displacement
-22 to 250 °F (-30 to 121 °C)(3)
Less than 0.005 in3 (0,08 cm3)
3051SAL Level Transmitter
Syltherm® XLT
-102 to 293 °F (-75 to 145 °C)
Silicone 704(8)
32 to 401 °F (0 to 205 °C)
Silicone 200
-49 to 401 °F (-45 to 205 °C)
Inert (Halocarbon)
-49 to 320 °F (-45 to 160 °C)
Glycerin and Water
5 to 203 °F (-15 to 95 °C)
Neobee M-20®(9)
5 to 401 °F (-15 to 205 °C)
Propylene Glycol and Water
5 to 203 °F (-15 to 95 °C)
(1) Process temperatures above 185 °F (85 °C) require derating the
ambient limits by a 1.5:1 ratio. For example, for process
temperature of 195 °F (91 °C), new ambient temperature limit is
equal to 170 °F (77 °C). This can be determined as follows:
(195 °F - 185 °F) x 1.5 = 15 °F,
185 °F - 15 °F = 170 °F
(2) 212 °F (100 °C) is the upper process temperature limit for DP
Range 0.
(3) 220 °F (104 °C) limit in vacuum service; 130 °F (54 °C) for
pressures below 0.5 psia.
Damping(1)
Analog output response time to a step change is user-selectable
from 0 to 60 seconds for one time constant. For 3051SMV,
3051SF_1-7, each variable can be individually adjusted. Software
damping is in addition to sensor module response time.
(1) Does not apply to wireless option code X.
Failure Mode Alarm
HART 4-20 mA (output option code A)
If self-diagnostics detect a gross transmitter failure, the analog
signal will be driven offscale to alert the user. Rosemount standard
(default), NAMUR, and custom alarm levels are available (see
Alarm Configuration below).
High or low alarm signal is software-selectable or
hardware-selectable via the optional switch (option D1).
Alarm Configuration
(4) -20 °F (-29 °C) is the lower process temperature limit with option
code P0.
(5) 32 °F (0 °C) is the lower process temperature limit for DP Range 0.
(6) For 3051S_C, 160 ° F (71 °C) limit in vacuum service.
For 3051SMV_ _ 1, 2, 140 ° F (60 °C) limit in vacuum service.
(7) Not available for 3051S_CA.
(8) Upper temperature limit is 464 °F (240 °C) for a 2-in. direct-mount
extension, 500 °F (260 °C) for a 4-in. direct-mount extension, and
599 °F (315 °C) for an In-Line Thermal Optimizer direct-mount
connection.
(9) Upper temperature limit is 437 °F (225 °C) for a 2-in. direct-mount
extension or greater.
Default
NAMUR compliant(1)
Custom levels(2) (3)
High Alarm
Low Alarm
21.75 mA
22.5 mA
20.2 - 23.0 mA
3.75 mA
3.6 mA
3.4 - 3.8 mA
(1) Analog output levels are compliant with NAMUR
recommendation NE 43, see option codes C4 or C5.
(2) Low alarm must be 0.1 mA less than low saturation and high
alarm must be 0.1 mA greater than high saturation.
(3) For 3051SMV and option code DA2, low alarm custom values
are 3.6 - 3.8 mA.
Safety-Certified Transmitter Failure
Values(1)
Safety accuracy: 2.0%(2)
Safety response time: 1.5 seconds
(1) Does not apply to wireless option code X.
(2) A 2% variation of the transmitter mA output is allowed before a
safety trip. Trip values in the DCS or safety logic solver should be
derated by 2%.
82
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
PHYSICAL SPECIFICATIONS
Drain/Vent Valves
Electrical Connections
316 SST, Alloy C-276, or Alloy 400/K-500(1) material
(Drain vent seat: Alloy 400, Drain vent stem: Alloy K-500)
1/2–14
NPT, G1/2, and M20 × 1.5 conduit. HART interface
connections fixed to terminal block for Output code A and X.
(1) Alloy 400/K-500 is not available with 3051SAL.
Process Flanges and Flange Adapters
Process Connections
Coplanar Sensor Module
(3051S_C, 3051SMV, 3051SF, 3051SAM_ _G or A)
Standard
Flange
Adapters
1
Standard
F11 Code
1
G11 Code
H11 Code
FF Seal
EF Seal
RF Seal
RT Seal
SC Seal
SS Seal
/4-18 NPT on 2 1/8-in. centers
/2-14 NPT and RC 1/2 on 2-in. (50.8 mm), 2 1/8-in.
(54.0 mm), or 2 1/4-in. (57.2 mm) centers
In-Line Sensor Module
(3051S_T, 3051SAM_ _T or E)
1
Wetted O-rings
Glass-filled PTFE
(Graphite-filled PTFE with Isolating Diaphragm code 6)
/2-14 NPT Female
Non-threaded instrument flange (available in SST
for sensor ranges 1-4 only)
G 1/2 A DIN 16288 Male (available in SST for
sensor ranges 1-4 only)
Autoclave type F-250C (Pressure relieved 9/16-18
gland thread; 1/4 OD high pressure tube 60° cone;
available in SST for sensor range 5 only)
Level Transmitter
(3051SAL)
3051SAL Mounting Flange
2-in. (DN 50), 3-in. (DN 80), or 4-in. (DN 100);
ANSI Class 150, 300, or 600 flange; JIS 10K, 20K,
or 40K flange; PN 10/16 or PN 40 flange
1-in. (DN 25) or 1.5-in. (DN 40); ANSI Class 150,
300, or 600 flange; JIS 10K, 20K, or 40K flange;
PN 40 flange
1/4-18, 1/2-14, 3/4-14, or 1-11.5 NPT Female
1.5-in, 2-in, or 3-in. Hygienic Tri-Clover Style
Tri-Clamp
4-in. Hygienic Tank Spud
Low-copper aluminum alloy or CF-8M (Cast 316 SST)
NEMA 4X, IP 66, IP 68 (66 ft (20 m) for 168 hours)
Note: IP 68 not available with Wireless Output.
Process-Wetted Parts
Process Isolating Diaphragms
Coplanar Sensor Module
(3051S_C, 3051SMV)
316L SST (UNS S31603), Alloy C-276 (UNS N10276), Alloy 400
(UNS N04400), Tantalum (UNS R05440), Gold-Plated Alloy 400,
Gold-plated 316L SST
B11 Code Low side process connection is SST
In-Line Sensor Module
(3051S_T)
316L SST (UNS S31603), Alloy C-276 (UNS N10276)
Level Transmitter
(3051SAL)
FF Seal
EF Seal
RF Seal
RT Seal
SC Seal
SS Seal
Plated carbon steel
SST: CF-8M (Cast 316 SST) per ASTM A743
Cast C-276: CW-12MW per ASTM A494
Cast Alloy 400: M-30C per ASTM A494
316L SST, Alloy C-276, Tantalum
Zinc-cobalt plated CS or 316 SST
3051SAL Seal Extension
CF-3M (Cast 316L SST, material per ASTM A743) or
CW-12MW (Cast C-276, material per ASTM A494)
Non-Wetted Parts
Electronics Housing
Coplanar Sensor Module Housing
SST: CF-3M (Cast 316L SST)
Bolts
Plated carbon steel per ASTM A449, Type 1
Austenitic 316 SST per ASTM F593
ASTM A453, Class D, Grade 660 SST
ASTM A193, Grade B7M alloy steel
ASTM A193, Class 2, Grade B8M SST
Alloy K-500
Sensor Module Fill Fluid
Silicone or inert halocarbon (Inert is not available with 3051S_CA).
In-Line series uses Fluorinert® FC-43.
Seal Fill Fluid (Liquid Level Only)
3051SAL: Syltherm XLT, Silicone 704, Silicone 200, inert, glycerin
and water, Neobee M-20, propylene glycol and water.
Paint for Aluminum Housing
Polyurethane
Cover O-rings
Buna-N
Wireless Antenna
316L SST, Alloy C-276
PBT/ polycarbonate (PC) integrated omnidirectional antenna
Power Module
Field replaceable, keyed connection eliminates the risk of incorrect
installation, Intrinsically Safe Lithium-thionyl chloride Power
Module with PBT enclosure
83
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Shipping Weights
Sensor Module Weights
Coplanar Sensor Module(1)
3.1 lb (1,4 kg)
In-Line Sensor Module
1.4 lb (0,6 kg)
(1) Flange and bolts not included.
Transmitter Weights(1)
Transmitter with Coplanar Sensor Module (3051S_C, 3051SMV, 3051SAM_ _G or A)
Junction Box Housing, SST Flange
6.3 lb (2,8 kg)
PlantWeb Housing, SST Flange
6.7 lb (3,1 kg)
Wireless PlantWeb Housing, SST Flange
7.3 lb (3,3 kg)
Transmitter with In-Line Sensor Module (3051S_T, 3051SAM_ _T or E)
Junction Box Housing
PlantWeb Housing
Wireless PlantWeb Housing
3.2 lb (1,4 kg)
3.7 lb (1,7 kg)
4.2 lb (1,9 kg)
(1) Fully functional transmitter with sensor module, housing, terminal block, and covers. Does not include LCD display.
Transmitter Option Weights
Option Code
1J, 1K, 1L
2J
7J
2A, 2B, 2C
1A, 1B, 1C
M5
B4
B1, B2, B3
B7, B8, B9
BA, BC
B4
F12, F22
F13, F23
E12, E22
F14, F24
F15, F25
G21
G22
G11
G12
G31
G41
Option
SST PlantWeb Housing
SST Junction Box Housing
SST Quick Connect
Aluminum Junction Box Housing
Aluminum PlantWeb Housing
LCD Display for Aluminum PlantWeb Housing(1),
LCD Display for SST PlantWeb Housing(1)
SST Mounting Bracket for Coplanar Flange
Mounting Bracket for Traditional Flange
Mounting Bracket for Traditional Flange with SST Bolts
SST Bracket for Traditional Flange
SST Mounting Bracket for In-Line
SST Traditional Flange with SST Drain Vents(2)
Cast C-276 Traditional Flange with Alloy C-276 Drain Vents(2)
SST Coplanar Flange with SST Drain Vents(2)
Cast Alloy 400 Traditional Flange with Alloy 400/K-500 Drain Vents(2)
SST Traditional Flange with Alloy C-276 Drain Vents(2)
Level Flange—3 in., 150
Level Flange—3 in., 300
Level Flange—2 in., 150
Level Flange—2 in., 300
DIN Level Flange, SST, DN 50, PN 40
DIN Level Flange, SST, DN 80, PN 40
(1) Includes LCD display and display cover.
(2) Includes mounting bolts.
84
Add lb (kg)
3.5 (1,6)
3.4 (1,5)
0.4 (0,2)
1.1 (0,5)
1.1 (0,5)
0.8 (0,4)
1.6 (0,7)
1.2 (0,5)
1.7 (0,8)
1.7 (0,8)
1.6 (0,7)
1.3 (0,6)
3.2 (1,5)
3.6 (1,6)
1.9 (0,9)
3.6 (1,6)
3.2 (1,5)
12.6 (5,7)
15.9 (7,2)
6.8 (3,1)
8.2 (3,7)
7.8 (3,5)
13.0 (5,9)
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Item
Weight in lb. (kg)
Aluminum Standard Cover
SST Standard Cover
Aluminum Display Cover
SST Display Cover
Wireless Extended Cover
LCD Display(1)
Junction Box Terminal Block
PlantWeb Terminal Block
Power Module
0.4 (0,2)
1.3 (0,6)
0.7 (0,3)
1.5 (0,7)
0.7 (0,3)
0.1 (0,04)
0.2 (0,1)
0.2 (0,1)
0.5 (0,2)
(1) Display only.
3051SAL Weights Without SuperModule Platform, Housing, or Transmitter Options
Flush
2-in. Ext.
4-in. Ext.
Flange
lb. (kg)
lb (kg)
lb (kg)
2-in., 150
9.5 (4,3)
—
—
3-in., 150
15.7 (7,1)
16.4 (7,4)
17.6 (8,0)
4-in., 150
21.2 (9,6)
20.9 (9,5)
22.1 (10,0)
2-in., 300
11.3 (5,1)
—
—
3-in., 300
19.6 (8,9)
20.3 (9,2)
21.5 (9,8)
4-in., 300
30.4 (13.8)
30.3 (13,7)
31.5 (14,3)
2-in., 600
12.8 (5,8)
—
—
3-in., 600
22.1 (10,0)
22.8 (10,3)
24.0 (10,9)
DN 50 / PN 40
11.3 (5,1)
—
—
DN 80 / PN 40
16.0 (7,3)
16.7 (7,6)
17.9 (8,1)
DN 100 / PN 10/16
11.2 (5,1)
11.9 (5,4)
13.1 (5,9)
DN 100 / PN 40
12.6 (5,7)
13.3 (6,0)
14.5 (6,6)
6-in. Ext.
lb (kg)
—
18.9 (8,6)
23.4 (10,6)
—
22.8 (10,3)
32.8 (14,9)
—
25.3 (11,5)
—
19.2 (8,7)
14.4 (6,5)
15.8 (7,1)
85
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Rosemount 3051S Certifications
Approved Manufacturing Locations
Rosemount Inc. — Chanhassen, Minnesota USA
Emerson Process Management GmbH & Co. — Wessling,
Germany
Emerson Process Management Asia Pacific Private Limited —
Singapore
Beijing Rosemount Far East Instrument Co., LTD — Beijing, China
Emerson Process Management LTDA — Sorocaba, Brazil
Emerson Process Management (India) Pvt. Ltd. — Mumbai, India
Emerson Process Management, Emerson FZE — Dubai, United
Arab Emirates
Ordinary Location Certification for FM
As standard, the transmitter has been examined and tested to
determine that the design meets basic electrical, mechanical, and
fire protection requirements by FM, a nationally recognized testing
laboratory (NRTL) as accredited by the Federal Occupational
Safety and Health Administration (OSHA).
European Directive Information
The EC declaration of conformity for all applicable European
directives for this product can be found at www.rosemount.com. A
hard copy may be obtained by contacting an Emerson Process
Management representative.
HART & FOUNDATION Fieldbus
Hazardous Locations Certifications
North American Certifications
FM Approvals
E5
I5/IE Intrinsically Safe for use in Class I, Division 1, Groups A, B,
C, and D, T4 (Ta = 70 °C for output options A or X; Ta = 60
°C for output option F); Class II, Division 1, Groups E, F, and
G; Class III, Division 1; Class I, Zone 0 AEx ia IIC T4 (Ta =
70 °C for output options A or X; Ta = 60 °C for output option
F) when connected in accordance with Rosemount drawing
03151-1006; Non-Incendive for Class I, Division 2, Groups
A, B, C, and D; T4 (Ta = 70 °C for output options A or X;
Ta = 60 °C for output option F) Enclosure Type 4X
For entity parameters see control drawing 03151-1006.
Canadian Standards Association (CSA)
All CSA hazardous approved transmitters are certified per
ANSI/ISA 12.27.01-2003.
ATEX Directive (94/9/EC)
Emerson Process Management complies with the
ATEX Directive.
European Pressure Equipment Directive (PED) (97/23/EC)
Models 3051S_CA4; 3051S_CD2, 3, 4, 5; (also with P9 option)
Pressure Transmitters — QS Certificate of Assessment EC No. 59552-2009-CE-HOU-DNV, Module H Conformity
Assessment
All other Model 3051S Pressure Transmitters
— Sound Engineering Practice
Transmitter Attachments: Diaphragm Seal - Process Flange Manifold — Sound Engineering Practice
Primary Elements, Flowmeter
— See appropriate Primary Element QIG
Electro Magnetic Compatibility (EMC) (2004/108/EC)
EN 61326-1:2006
EN 61326-2-3:2006
86
Explosion-proof for Class I, Division 1, Groups B, C, and D,
T5 (Ta = 85 °C); Dust Ignition-proof for Class II and Class III,
Division 1, Groups E, F, and G, T5 (Ta = 85 °C); hazardous
locations; enclosure Type 4X, conduit seal not required
when installed according to Rosemount drawing
03151-1003.
E6
Explosion-proof for Class I, Division 1, Groups B, C, and D;
Dust Ignition-proof for Class II and Class III, Division 1,
Groups E, F, and G; suitable for Class I, Division 2, Groups
A, B, C, and D, when installed per Rosemount drawing
03151-1013, CSA Enclosure Type 4X; conduit seal not
required; Dual Seal.
I6/IF Intrinsically Safe for Class I, Division 1, Groups A, B, C, and
D when connected in accordance with Rosemount drawings
03151-1016; Dual Seal.
For entity parameters see control drawing 03151-1016.
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
European Certifications
Rosemount 3051S Series
ND
I1/IA ATEX Intrinsic Safety
Certificate No.: BAS01ATEX1303X
II 1G
Ex ia IIC T4 (Ta = -60 °C to 70 °C) -HART/Remote
Display/Quick Connect/HART Diagnostics
Ex ia IIC T4 (Ta = -60 °C to 70 °C) -FOUNDATION fieldbus
Ex ia IIC T4 (Ta = -60 °C to 40 °C) -FISCO
1180
Special conditions for safe use (x)
1. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP66.
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the
enclosure to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient range of the apparatus and capable of
withstanding a 7J impact test.
4. The 3051S SuperModule must be securely screwed in
place to maintain the ingress protection of the enclosure.
(The 3051S SuperModule must be properly assembled to
the 3051S housing to maintain ingress protection.)
Input Parameters
Loop /
Power
Groups
HART / FOUNDATION fieldbus/ Remote Display /
Quick Connect / HART Diagnostics
Ui = 17.5 V
FISCO
Ii = 300 mA
HART / FOUNDATION fieldbus/ Remote Display /
Quick Connect / HART Diagnostics
Ii = 380 mA
FISCO
Pi = 1.0 W
HART / Remote Display / Quick Connect /
HART Diagnostics
Pi = 1.3 W
FOUNDATION fieldbus
Pi = 5.32 W FISCO
Ci = 30 nF
SuperModule Platform
Ci = 11.4 nF HART / HART Diagnostics / Quick Connect
Ci = 0
FOUNDATION fieldbus / Remote Display / FISCO
Li = 0
HART / FOUNDATION fieldbus/ FISCO / Quick
Connect / HART Diagnostics
Li = 60 µH
Remote Display
RTD Assembly (3051SFx Option T or R)
Ui = 30 V
Ui = 5 Vdc
Ii = 500 mA
Pi = 0.63 W
Special conditions for safe use (x)
1. The apparatus, excluding the Types 3051 S-T and 3051
S-C (In-line and Coplanar SuperModule Platforms
respectively), is not capable of withstanding the 500V test
as defined in Clause 6.4.12 of EN 60079-11. This must be
considered during installation.
ATEX Dust
Certificate No.: BAS01ATEX1374X
II 1 D
Ex tD A20 IP66 T105°C (-20 °C  Tamb  85 °C)
Vmax = 42.4 volts max
IP66
1180
E1
ATEX Flameproof
Certificate No.: KEMA00ATEX2143X
Ex d IIC T6 (-50 °C  Tamb  65 °C)
Ex d IIC T5 (-50 °C  Tamb  80 °C)
Vmax = 42.4V
1180
II 1/2 G
Special conditions for safe use (x)
1. The Ex d blanking elements, cable glands and wiring
shall be suitable for a temperature of 90 °C.
2. The 3051S SuperModule contains a thin wall diaphragm.
Installation, maintenance and use shall take into account
the environmental conditions to which the diaphragm will
be subjected. The manufacturer's instructions for
maintenance shall be followed in detail to assure safety
during its expected lifetime.
3. In case of repair, contact the manufacturer for information
on the dimensions of the flameproof joints.
2. The terminal pins of the Types 3051 S-T and 3051 S-C
must be protected to IP20 minimum.
N1
ATEX Type n
Certificate No.: BAS01ATEX3304X
II 3 G
Ex nL IIC T4 (Ta = -40 °C TO 70 °C)
Ui = 45 Vdc max
Ci = 11.4 nF (Transmitter Output Option A)
Ci = 0 (Transmitter Output Option F)
Li = 0
For remote display, Ci = 0, Li = 60 μH
IP66
Special conditions for safe use (x)
The apparatus is not capable of withstanding the 500V
insulation test required by Clause 6.8.1 of EN 60079-15.
This must be taken into account when installing the apparatus.
NOTE
RTD Assembly is not included with the 3051SFx Type n Approval.
87
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Japanese Certifications
E4
TIIS Flameproof
Ex d IIC T6
Certificate
Description
TC15682
TC15683
TC15684
Coplanar with Junction Box Housing
Coplanar with PlantWeb Housing
Coplanar with PlantWeb Housing
and LCD Display
In-Line SST with Junction Box Housing
In-Line Alloy C-276 with Junction Box Housing
In-Line SST with PlantWeb Housing
In-Line Alloy C-276 with PlantWeb Housing
In-Line SST with PlantWeb Housing
and LCD Display
In-Line Alloy C-276 with PlantWeb Housing
and LCD Display
Remote Display
3051SFA/C/P SST/Alloy C-276 with
PlantWeb Housing and LCD Display
3051SFA/C/P SST/Alloy C-276 with
PlantWeb Housing and Remote Display
3051SFA/C/P SST/Alloy C-276 with
Junction Box Housing
TC15685
TC15686
TC15687
TC15688
TC15689
TC15690
TC17102
TC17099
TC17100
TC17101
Input Parameters
Loop /
Power
HART / FOUNDATION fieldbus / Remote Display /
Quick Connect / HART Diagnostics
Ii = 300 mA
HART / FOUNDATION fieldbus / Remote Display /
Quick Connect / HART Diagnostics
Pi = 1.0 W
HART / Remote Display / Quick Connect /
HART Diagnostics
Pi = 1.3 W
FOUNDATION fieldbus
Ci = 38 nF
SuperModule Platform
Ci = 11.4 nF HART / HART Diagnostics / Quick Connect
Ci = 0
FOUNDATION fieldbus / Remote Display
Li = 0
SuperModule Platform / FOUNDATION fieldbus
Li = 2.4 µH
HART / Quick Connect / HART Diagnostics
Li = 58.2 µH Remote Display
RTD Assembly (3051SFx Option T or R)
Ui = 5 Vdc
Ii = 500 mA
Pi = 0.63 W
N3
China Certifications
E3
China Flameproof, Dust Ignition-proof
NEPSI Certificate No. (manufactured in Chanhassen, MN):
GYJ091035
Certificate No. (manufactured in Beijing, China): GYJ06366
Certificate No. (manufactured in Singapore): GYJ06364
Certificate No. (3051SFx RTC, BMMC, SMMC): GYJ071086
Ex d IIB+H2 T3~T5
DIP A21 TA T3~T5 IP66
NOTE
Refer to Appendix B of the 3051S Reference Manual (document
number 00809-0100-4801) for Special Conditions for Safe Use.
I3
China Intrinsic Safety, Dust Ignition-proof
NEPSI Certificate No. (manufactured in Chanhassen, MN):
GYJ081078
Certificate No. (manufactured in Beijing, China): GYJ06367
Certificate No. (manufactured in Singapore): GYJ06365
Certificate No. (3051SFx RTC, BMMC, SMMC): GYJ071293
Ex ia IIC T4
DIP A21 TA T4 IP66
NOTE
Refer to Appendix B of the 3051S Reference Manual (document
number 00809-0100-4801) for Special Conditions for Safe Use.
Groups
Ui = 30 V
China Type n - Energy Limited
NEPSI Certificate No.: GYJ101112X
Ex nL IIC T5 (-40 °C ≤ Ta ≤ 70 °C)
IP66
Loop /
Power
Transmitter Output
Ui = 30 V
Ii = 300 mA
Pi = 1.0 W
Pi = 1.3 W
Ci = 11.4 nF
Ci = 0 nF
Li = 0 µH
HART / FOUNDATION fieldbus
HART / FOUNDATION fieldbus
HART
FOUNDATION fieldbus
HART
FOUNDATION fieldbus
HART(1) / FOUNDATION fieldbus
(1) For remote meter option (M7, M8, M9), Li = 60 µH.
NOTE
Refer to Appendix B of the 3051S Reference Manual (document
number 00809-0100-4801) for Special Conditions for Safe Use.
Brazil Certifications
I2
INMETRO Intrinsic Safety
Certificate number: CEPEL-EX-0722/05X
(manufacturing in Chanhassen, MN and Singapore)
Certificate number: CEPEL-EX-1414/07X
(manufacturing in Brazil)
INMETRO Marking: BR-Ex ia IIC T4 IP66W
Special conditions for safe use (x)
The apparatus, excluding the Types 3051S-T and 3051S-C
(In-line and Coplanar SuperModule Platforms respectively),
is not capable of withstanding the 500V test as defined in
Clause 6.4.12 of IEC60079-11. This must be considered
during installation.
88
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
E2
INMETRO Flameproof
Certificate number: CEPEL-EX-140/2003X
(manufacturing in Chanhassen, MN and Singapore)
Certificate number: CEPEL-EX-1413/07X
(manufacturing in Brazil)
INMETRO Marking: BR-Ex d IIC T5/T6 IP66W
Special conditions for safe use (x)
1. This device contains a thin wall diaphragm. Installation,
maintenance, and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer’s instructions for installation
and maintenance shall be followed in detail to assure
safety during its expected lifetime.
2. For ambient temperature above 60 ºC, cable wiring must
have minimum isolation temperature of 90 ºC, to be in
accordance to equipment operation temperature.
3. The accessory of cable entries or conduit must be
certified as flameproof and needs to be suitable for use
conditions.
4. Where electrical entry is via conduit, the required sealing
device must be assembled immediately close to
enclosure.
Rosemount 3051S Series
IECEx Certifications
E7
IECEx Flameproof and Dust (each listed separately)
IECEx Flameproof
Certificate No.: IECExKEM08.0010X
Ex d IIC T5 or T6 Ga/Gb
T6 (-50 °C  Tamb  65 °C)
T5 (-50 °C  Tamb  80 °C)
Vmax = 42.4V
Special conditions for safe use (x)
1. The Ex d blanking elements, cable glands and wiring
shall be suitable for a temperature of 90 °C.
2. The 3051S SuperModule contains a thin wall diaphragm.
Installation, maintenance and use shall take into account
the environmental conditions to which the diaphragm will
be subjected. The manufacturer's instructions for
maintenance shall be followed in detail to assure safety
during its expected lifetime.
3. In case of repair, contact the manufacturer for information
on the dimensions of the flameproof joints.
IECEx Dust
Certificate No. IECExBAS09.0014X
Ex tD A20 IP66 T105 °C (-20 °C ≤ Ta ≤ 85 °C)
Vmax = 42.4 V
A = 22 mA
IP66
Special conditions for safe use (x)
1. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP66.
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the
enclosure to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient range of the apparatus and capable of
withstanding a 7J impact test.
4. The 3051S SuperModule must be securely screwed in
place to maintain the ingress protection of the enclosure.
(The 3051S SuperModule must be properly assembled to
the 3051S housing to maintain ingress protection.)
89
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
I7/IG IECEx Intrinsic Safety
Certificate No.: IECExBAS04.0017X
Ex ia IIC T4 (Ta = -60 °C to 70 °C) -HART/Remote
Display/Quick Connect/HART Diagnostics
Ex ia IIC T4 (Ta = -60 °C to 70 °C) -FOUNDATION fieldbus
Ex ia IIC T4 (Ta = -60 °C to 40 °C) -FISCO
IP66
Input Parameters
Loop / Power
Groups
Ui = 30 V
HART / FOUNDATION fieldbus/ Remote
Display / Quick Connect / HART
Diagnostics
Ui = 17.5 V
FISCO
Ii = 300 mA
HART / FOUNDATION fieldbus/ Remote
Display / Quick Connect / HART
Diagnostics
Ii = 380 mA
FISCO
Pi = 1.0 W
HART / Remote Display / Quick
Connect / HART Diagnostics
Pi = 1.3 W
FOUNDATION fieldbus
Pi = 5.32 W
FISCO
Ci = 30 nF
SuperModule Platform
Ci = 11.4 nF
HART / HART Diagnostics / Quick
Connect
Ci = 0
FOUNDATION fieldbus / Remote Display /
FISCO
Li = 0
HART / FOUNDATION fieldbus/ FISCO /
Quick Connect / HART Diagnostics
Li = 60 H
Remote Display
RTD Assembly (3051SFx Option T or R)
Ui = 5 Vdc
Ii = 500 mA
Pi = 0.63 W
Special conditions for safe use (x)
1. The 3051S HART 4-20 mA, 3051S FOUNDATION fieldbus,
and 3051S FISCO are not capable of withstanding the
500V test as defined in clause 6.4.12 of IEC 60079-11.
This must be taken into account during installation.
2. The terminal pins of the Types 3051S-T and 3051S-C must
be protected to IP20 minimum.
N7
90
IECEx Type n
Certificate No.: IECExBAS04.0018X
Ex nC IIC T4 (-40 °C ≤ Ta ≤ +70 °C)
IP66
Special conditions for safe use (x)
The apparatus is not capable of withstanding the 500 V
insulation test required by Clause 8 of IEC 60079-15:1987.
Combinations of Certifications
Stainless steel certification tag is provided when optional approval
is specified. Once a device labeled with multiple approval types is
installed, it should not be reinstalled using any other approval
types. Permanently mark the approval label to distinguish it from
unused approval types.
K1
Combination of E1, I1, N1, and ND
K2
Combination of E2 and I2
K5
Combination of E5 and I5
K6
Combination of E6 and I6
K7
Combination of E7, I7, and N7
KA
Combination of E1, I1, E6, and I6
KB
Combination of E5, I5, I6, and E6
KC
Combination of E5, E1, I5, and I1
KD
Combination of E5, I5, E6, I6, E1, and I1
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Rosemount 3051S Wireless Certifications
Approved Manufacturing Locations
Rosemount Inc. — Chanhassen, Minnesota USA
Emerson Process Management GmbH & Co. — Wessling,
Germany
Emerson Process Management Asia Pacific Private Limited —
Singapore
Beijing Rosemount Far East Instrument Co., LTD — Beijing, China
Emerson Process Management LTDA — Sorocaba, Brazil
Emerson Process Management (India) Pvt. Ltd. — Mumbai, India
Radio and Telecommunications Terminal Equipment Directive
(R&TTE)(1999/5/EC)
Emerson Process Management complies with the R&TTE
Directive.
Telecommunication Compliance
Hazardous Locations Certifications
All wireless devices require certification to ensure that they adhere
to regulations regarding the use of the RF spectrum. Nearly every
country requires this type of product certification. Emerson is
working with governmental agencies around the world to supply
fully compliant products and remove the risk of violating country
directives or laws governing wireless device usage.
Electro Magnetic Compatibility (EMC) (2004/108/EC)
EN 61326-1:2006
EN 61326-2-3:2006
North American Certifications
Factory Mutual (FM) Approvals
I5
FCC and IC Approvals
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following conditions: This device may not cause
harmful interference and must accept any interference received,
including interference that may cause undesired operation.
This device must be installed to ensure a minimum antenna
separation distance of 20 cm from all persons.
Ordinary Location Certification for FM
As standard, the transmitter has been examined and tested to
determine that the design meets basic electrical, mechanical, and
fire protection requirements by FM, a nationally recognized testing
laboratory (NRTL) as accredited by the Federal Occupational
Safety and Health Administration (OSHA).
European Directive Information
The EC declaration of conformity for all applicable European
directives for this product can be found at www.rosemount.com. A
hard copy may be obtained by contacting an Emerson Process
Management representative.
ATEX Directive (94/9/EC)
FM Intrinsically Safe, Non-Incendive, and Dust
Ignition-proof.
Intrinsically Safe for Class I/II/III, Division 1,
Groups A, B, C, D, E, F, and G.
Zone Marking: Class I, Zone 0, AEx ia llC
Temperature Codes T4 (Tamb = -50 to 70 °C)
Non-Incendive for Class I, Division 2, Groups A, B, C, and
D.
Dust Ignition-proof for Class II/III, Division 1,
Groups E, F, and G.
Ambient temperature limits: -50 to 85 °C
For use with Rosemount SmartPower options
00753-9220-0001 only.
Enclosure Type 4X / IP66
CSA - Canadian Standards Association
Process Sealing
All CSA hazardous approved transmitters are certified per
ANSI/ISA 12.27.01-2003.
I6
CSA Intrinsically Safe
Intrinsically Safe for Class I, Division 1, Groups A, B, C, and
D.
Temp Code T3C
Enclosure Type 4X / IP66
For use with Rosemount SmartPower options
00753-9220-0001 only.
Emerson Process Management complies with the ATEX
Directive.
European Pressure Equipment Directive (PED) (97/23/EC)
Models 3051S_CA4; 3051S_CD2, 3, 4, 5; (also with P9 option)
Pressure Transmitters — QS Certificate of Assessment EC No. 59552-2009-CE-HOU-DNV,
Module H Conformity Assessment
All other Model 3051S Pressure Transmitters
— Sound Engineering Practice
Transmitter Attachments: Diaphragm Seal - Process Flange Manifold — Sound Engineering Practice
Primary Elements, Flowmeter
— See appropriate Primary Element QIG
91
Product Data Sheet
Rosemount 3051S Series
European Certifications
I1
ATEX Intrinsic Safety
Certificate No.: BAS01ATEX1303X
II 1G
Ex ia IIC T4 (Ta = -60 °C to 70 °C)
IP66
For use with Rosemount SmartPower options
00753-9220-0001 only.
Special conditions for safe use (x)
The surface resistivity of the antenna is greater than one
gigaohm. To avoid electrostatic charge build-up, it must not
be rubbed or cleaned with solvents or a dry cloth.
1180
Country
Bulgaria
France
Italy
Norway
Romania
Restriction
General authorization required for outdoor use and
public service
Outdoor use limited to 10mW e.i.r.p.
If used outside of own premises, general authorization
is required.
May be restricted in the geographical area within a
radius of 20 km from the center of Ny-Alesund.
Use on a secondary basis. Individual license required.
IECEx Certifications
I7
IECEx Intrinsic Safety
Certificate No.: IECEx BAS 04.0017X
Ex ia IIC T4 (Ta = -60 °C to 70 °C)
For use with Rosemount SmartPower options
00753-9220-0001 only.
IP66
Special conditions for safe use (x)
The surface resistivity of the antenna is greater than one
gigaohm. To avoid electrostatic charge build-up, it must not
be rubbed or cleaned with solvents or a dry cloth.
92
00813-0100-4801, Rev PA
April 2011
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Rosemount 3051S MultiVariable Certifications
Approved Manufacturing Locations
Canadian Standards Association (CSA)
All CSA hazardous approved transmitters are certified per
ANSI/ISA 12.27.01-2003.
Rosemount Inc. — Chanhassen, Minnesota USA
Emerson Process Management GmbH & Co. — Wessling,
Germany
E6
Explosion-proof for Class I, Division 1, Groups B, C, and D;
Dust-Ignition-Proof for Class II and Class III, Division 1,
Groups E, F, and G; suitable for Class I, Division 2, Groups
A, B, C, and D, CSA Enclosure Type 4X; conduit seal not
required. Dual Seal. T5 (Ta = -40 °C to 85 °C).
I6
Intrinsically Safe for Class I, Division 1, Groups A, B, C, and
D, T3C; when connected in accordance with Rosemount
drawings 03151-1207; Dual Seal.
For entity parameters see control drawing 03151-1207.
Emerson Process Management Asia Pacific Private Limited —
Singapore
Ordinary Location Certification for FM
As standard, the transmitter has been examined and tested to
determine that the design meets basic electrical, mechanical, and
fire protection requirements by FM, a nationally recognized testing
laboratory (NRTL) as accredited by the Federal Occupational
Safety and Health Administration (OSHA).
European Directive Information
The EC declaration of conformity for all applicable European
directives for this product can be found at www.rosemount.com. A
hard copy may be obtained by contacting an Emerson Process
Management representative.
ATEX Directive (94/9/EC)
Emerson Process Management complies with the
ATEX Directive.
European Pressure Equipment Directive (PED) (97/23/EC)
Models with Differential Pressure Ranges = 2 through 5 and/or
Static Pressure Range 4 or options P0 and P9.
QS Certificate of Assessment - EC No.
59552-2009-CE-HOU-DNV,
Module H Conformity Assessment
— Sound Engineering Practice
Transmitter Attachments: Diaphragm Seal - Process Flange Manifold — Sound Engineering Practice
Primary Elements, Flowmeter
— See appropriate Primary Element QIG
Electro Magnetic Compatibility (EMC) (2004/108/EC)
EN 61326-1:2006 and EN 61326-2-3:2006
European Certifications
I1
ATEX Intrinsic Safety
Certificate No.: Baseefa 08ATEX0064X
Ex ia IIC T4 (-60 °C  Tamb  +70 °C)
1180
II 1G
Field Connection / 4-20 mA Loop Parameters
Ui = 30 V
Ii = 300 mA
Pi = 1.0 W
Ci = 14.8 nF
Li = 0
RTD Connection Parameters
UO = 30 V
IO = 2.31 mA
PO = 17.32 mW
Ci = 0
Li = 0
Special conditions for safe use (x)
If the equipment is fitted with the optional 90 V transient
suppressor, it is incapable of withstanding the 500 V isolation
from earth test and this must be taken into account during
installation.
N1
Hazardous Locations Certifications
North American Certifications
ATEX Type n
Certificate No.: Baseefa 08ATEX0065X
Ex nA nL IIC T4 (-40 °C  Tamb  +70 °C)
Ui = 45 Vdc max
UO = 30 V (RTD Connection)
IP66
II 3 G
FM Approvals
E5
Explosion-proof for Class I, Division 1, Groups B, C, and D;
dust-ignition proof for Class II and Class III, Division 1,
Groups E, F, and G; Ta = 85 °C; hazardous locations;
enclosure Type 4X, conduit seal not required.
I5
Intrinsically Safe for use in Class I, Division 1, Groups A, B,
C, and D; Class II, Division 1, Groups E, F, and G; Class III,
Division 1; Class I, Zone 0 AEx ia IIC when connected in
accordance with Rosemount drawing 03151-1206;
Ta = 70 °C;
Non-incendive for Class I, Division 2, Groups A, B, C, and D
Enclosure Type 4X
For entity parameters see control drawing 03151-1206.
Special conditions for safe use (x)
If fitted with a 90 V transient suppressor, the equipment is not
capable of withstanding the 500 V electrical strength test as
defined in Clause 6.8.1 of EN 60079-15:2005. This must be
taken into account during installation.
ND
ATEX Dust
Certificate No.: BAS01ATEX1374X
II 1 D
Ex tD A20 IP66 T105°C (-20 °C  Tamb  85 °C)
IP66
1180
93
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Special conditions for safe use (x)
INMETRO Intrinsic Safety
Certificate No. NCC 5870/09X
BR-Ex ia IIC T4 (-60 °C  Ta  70 °C) Ga IP66W
I2
1. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP66.
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the enclosure
to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient temperature range of the apparatus and capable of
withstanding a 7J impact test.
4. The 3051S SuperModule must be securely screwed in place
to maintain the ingress protection of the enclosure.
E1
ATEX Flameproof
Certificate No.: KEMA00ATEX2143X
Ex d IIC T6 (-50 °C  Tamb  65 °C)
Ex d IIC T5 (-50 °C  Tamb  80 °C)
Vmax = 42.4V
1180
II 1/2 G
Field Connection / 4-20 mA Loop Parameters
Ui = 30 V
Ii = 300 mA
Pi = 1.0 W
Ci = 14.8 nF
Li = 0
RTD Connection Parameters
UO = 30 V
IO = 2.31 mA
PO = 17.32 mW
Ci = 0
Li = 0
Special conditions for safe use (x)
1. The Ex d blanking elements, cable glands and wiring
shall be suitable for a temperature of 90 °C.
1. If the equipment is fitted with the option 90 V transient
suppressor, it is incapable of withstanding the 500 V
isolation from earth test and this must be taken into account
during installation.
2. Transmitter Model 3051S contains a thin wall diaphragm.
Installation, maintenance and use shall take into account
the environmental conditions to which the diaphragm will
be subjected. The manufacturer's instructions for
maintenance shall be followed in detail to assure safety
during its expected lifetime.
2. For processes with temperatures above 135 °C, the user
should evaluate whether the SuperModule temperature
class is suitable for the application. The temperatures of the
SuperModule may be above class T4, considering that this
temperature depends on the type of ventilation used on the
equipment.
Special conditions for safe use (x)
3. In case of repair, contact the manufacturer for information
on the dimensions of the flameproof joints.
Japanese Certifications
E4
TIIS Flameproof
Ex d IIC T6
TC19070 With RTD and LCD Display
TC19071 With LCD
TC19072 RTD without LCD Display
TC19073 Without LCD
Brazil Certifications
E2
INMETRO Flameproof
Certificate number: NCC 5886/09X
BR-Ex d IIC T5/T6 Gb IP66W
T6 (-50 °C to 65 °C)
T5 (-50 °C to 80 °C)
Special conditions for safe use (x)
For processes with temperatures above 135 °C, the user should
evaluate whether the SuperModule temperature class is suitable
for the application. The temperatures of the SuperModule may be
above class T4, considering that this temperature depends on the
type of ventilation used on the equipment.
China Certifications
E3
China Flameproof
NEPSI Certificate No.: GYJ091001
Ex d IIC T5/T6
T6 (-50 °C to 65 °C)
T5 (-50 °C to 80 °C)
NOTE
Refer to Appendix B of the 3051S MultiVariable Reference Manual
(document number 00809-0100-4803) for Special Conditions for
Safe Use.
I3
China Intrinsic Safety
NEPSI Certificate No.: GYJ091002X
Ex ia IIC T4 (-60 °C to 70 °C)
Field Connection / 4-20 mA Loop Parameters
Ui = 30 V
Ii = 300 mA
Pi = 1.0 W
Ci = 14.8 nF
Li = 0
RTD Connection Parameters
UO = 30 V
IO = 2.31 mA
PO = 17.32 mW
Ci = 0
Li = 0
94
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
NOTE
Refer to Appendix B of the 3051S MultiVariable Reference Manual
(document number 00809-0100-4803) for Special Conditions for
Safe Use.
IECEx Certifications
I7
IECEx Intrinsic Safety
Certificate No.: IECExBAS08.0025X
Ex ia IIC T4(-60 °C  Ta  70 °C)
IP66
Rosemount 3051S Series
K1
Combination of E1, I1, N1, and ND
K4
Combination of E4 and I4
K5
Combination of E5 and I5
K6
Combination of E6 and I6
K7
Combination of E7, I7, and N7
KA
Combination of E1, E6, I1, and I6
KB
Combination of E5, E6, I5, and I6
KC
Combination of E5, E1, I5, and I1
KD
Combination of E5, E6, E1, I5, I6, and I1
Field Connection / 4-20 mA Loop Parameters
Ui = 30 V
Ii = 300 mA
Pi = 1.0 W
Ci = 14.8 nF
Li = 0
RTD Connection Parameters
UO = 30 V
IO = 2.31 mA
PO = 17.32 mW
Ci = 0
Li = 0
Special conditions for safe use (x)
If the equipment is fitted with the optional 90 V transient
suppressor, it is incapable of withstanding the 500 V isolation from
earth test and this must be taken into account during installation.
N7
IECEx Type n
Certificate No.: IECExBAS08.0026X
Ex nAnL IIC T4 (-40 °C  Ta  70 °C)
Ui = 45 Vdc MAX
UO = 30 V (RTD Connection)
IP66
Special conditions for safe use (x)
If fitted with a 90 V transient suppressor, the equipment is
not capable of withstanding the 500 V electrical strength test
as defined in Clause 6.8.1 of EN 60079-15:2005. This must
be taken into account during installation.
E7
IECEx Flameproof
Certificate No.: IECExKEM08.0010X
Ex d IIC T6 (-50 °C  Tamb  65 °C)
Ex d IIC T5 (-50 °C  Tamb  80 °C)
Special conditions for safe use (x)
1. The Ex d blanking elements, cable glands and wiring
shall be suitable for a temperature of 90 °C.
2. Transmitter Model 3051S contains a thin wall diaphragm.
Installation, maintenance and use shall take into account
the environmental conditions to which the diaphragm will
be subjected. The manufacturer's instructions for
maintenance shall be followed in detail to assure safety
during its expected lifetime.
3. In case of repair, contact the manufacturer for information
on the dimensions of the flameproof joints.
Combinations of Certifications
Stainless steel certification tag is provided when optional approval
is specified. Once a device labeled with multiple approval types is
installed, it should not be reinstalled using any other approval
types. Permanently mark the approval label to distinguish it from
unused approval types.
95
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
3051S ERS System Certifications
Approved Manufacturing Locations
European Certifications
Rosemount Inc. – Chanhassen, Minnesota, USA
Emerson Process Management GmbH & Co. – Wessling,
Germany
Emerson Process Management Asia Pacific Private Limited –
Singapore
Beijing Rosemount Far East Instrument Co., LTD – Beijing, China
I1
N1
ND
Ordinary Location Certification for FM
Approvals
As standard, the transmitter has been examined and tested to
determine that the design meets basic electrical, mechanical, and
fire protection requirements by FM, a nationally recognized testing
laboratory (NRTL) as accredited by the Federal Occupational
Safety and Health Administration (OSHA).
Consult your Emerson Process Management sales representative
for more information about the EC declaration of conformity.
Hazardous Locations Certifications
North American Certifications
E1
I6
Explosion-proof for Class I, Division 1, Groups B, C, and D;
Dust Ignition-Proof for Class II and Class III, Division 1,
Groups E, F, and G; suitable for Class I, Division 2, Groups
A, B, C, and D, CSA Enclosure Type 4X; conduit seal not
required; Dual Seal.
Intrinsically Safe for Class I, Division 1, Groups A, B, C, and
D when connected in accordance with Rosemount Drawings
03151-1316; Dual Seal.
For entity parameters see control drawing 03151-1316.
ATEX Flameproof
Certificate No.: KEMA00ATEX2143X
Ex d IIC T6 (-50 °C  Tamb  65 °C)
Ex d IIC T5 (-50 °C  Tamb  80 °C)
Vmax = 42.4 V
1180
Special Conditions for safe use (X):
II 1/2 G
1. The Ex d blanking elements, cable glands and wiring
shall be suitable for a temperature of 90 °C.
2. Transmitter Model 3051S contains a thin wall diaphragm.
Installation, maintenance and use shall take into account
the environmental conditions to which the diaphragm will
be subjected. The manufacturer's instructions for
maintenance shall be followed in detail to assure safety
during its expected lifetime.
Canadian Standards Association (CSA)
All CSA hazardous approved transmitters are certified per
ANSI/ISA 12.27.01-2003.
E6
ATEX Dust
Certificate No.: BAS01ATEX1374X
II 1 D
Ex tD A20 IP66 T105 °C (-20 °C  Tamb  85 °C)
Vmax = 42.4 V max
IP66
1180
Special Conditions for safe use (X):
1. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP66.
2. Unused cable entries must be filled suitable blanking
plugs which maintain the ingress protection of the
enclosure to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient range of the apparatus and capable of
withstanding a 7J impact test.
4. Each 3051S ERS transmitter must be securely screwed
in place to maintain the ingress protection of the
enclosure. (The 3051S Super Module must be properly
assembled to the 3051S housing to maintain ingress
protection.)
European Directive Information
FM Approvals
E5 Explosion-proof for Class I, Division 1, Groups B, C, and D;
Dust Ignition-proof for Class II and Class III, Division 1,
Groups E, F, and G; hazardous locations; enclosure Type
4X, conduit seal not required.
I5
Intrinsically Safe for use in Class I, Division 1, Groups A, B,
C, and D; Class II, Division 1, Groups E, F, and G; Class III,
Division 1; Class I, Zone 0 AEx ia IIC when connected in
accordance with Rosemount drawing 03151-1306;
Non-Incendive for Class I, Division 2, Groups A, B, C, and D
Enclosure Type 4X
For entity parameters see control drawing 03151-1306.
ATEX Intrinsic Safety
Consult factory for availability.
ATEX Type n
Consult factory for availability.
3. In case of repair, contact the manufacturer for information
on the dimensions of the flameproof joints.
Japanese Certifications
E4
TIIS Flameproof: Consult factory for availability
INMETRO Certifications
E2
INMETRO Flameproof: Consult factory for availability
I2
INMETRO Intrinsic Safety: Consult factory for availability
China Certifications
96
E3
China Flameproof: Consult factory for availability
I3
China Intrinsically Safe: Consult factory for availability
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
IECEx Certifications
I7
IECEx Intrinsic Safety
Consult factory for availability.
N7
IECEx Type n
Consult factory for availability.
E7
IECEx Flameproof and Dust (each listed separately)
IECEx Flameproof
Certificate No.: IECExKEM08.0010X
Ex d IIC T6 (-50 °C  Tamb  65 °C)
Ex d IIC T5 (-50 °C  Tamb  80 °C)
Vmax = 42.4 V
Special conditions for safe use (X)
1. The Ex d blanking elements, cable glands and wiring
shall be suitable for a temperature of 90 °C.
Rosemount 3051S Series
Combinations of Certifications
Stainless steel certification tag is provided when optional approval
is specified. Once a device labeled with multiple approval types is
installed, it should not be reinstalled using any other approval
types. Permanently mark the approval label to distinguish it from
unused approval types.
K1
K2
K5
K6
K7
KA
KB
KC
KD
Combination of E1, I1, N1, and ND
Combination of E2 and I2
Combination of E5 and I5
Combination of E6 and I6
Combination of E7, I7, and N7
Combination of E1, E6, I1, and I6
Combination of E5, E6, I1, and I6
Combination of E5, E1, I5, and I1
Combination of E5, E6, E1, I5, I6, and I1
2. Transmitter Model 3051S contains a thin wall diaphragm.
Installation, maintenance and use shall take into account
the environmental conditions to which the diaphragm will
be subjected. The manufacturer's instructions for
maintenance shall be followed in detail to assure safety
during its expected lifetime.
3. In case of repair, contact the manufacturer for information
on the dimensions of the flameproof joints.
IECEx Dust
Certificate No. IECExBAS09.0014X
Ex tD A20 IP66 T105°C (-20 °C ≤ Tamb ≤ 85 °C)
Vmax = 42.4 V
A = 22 mA
IP66
Special conditions for safe use (x)
1. Cable entries must be used which maintain the ingress
protection of the enclosure to at least IP66.
2. Unused cable entries must be filled with suitable blanking
plugs which maintain the ingress protection of the
enclosure to at least IP66.
3. Cable entries and blanking plugs must be suitable for the
ambient range of the apparatus and capable of
withstanding a 7J impact test.
4. Each 3051S ERS sensor must be securely screwed in
place to maintain the ingress protection of the enclosure.
(Each sensor module must be properly assembled to the
housing to maintain ingress protection.)
97
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Dimensional Drawings
Figure 1. Transmitter with Coplanar Sensor Module and Flange
PlantWeb Housing
Junction Box Housing
Wireless Housing
Front View
Front View
Front View
4.20 (107)
Extended Range
External Antenna
4.20 (107)
External
Antenna
8.53
(217)
8.53
(217)
9.63
(245)
Side View
4.55 (116)
6.93
(176)
90°
10.91
(277)
4.20
(107)
9.63
(245)
Side View
Side View
3.45 (88)
3.46
(87.8)
6.72
(171)
6.06
(155)
7.70
(196)
8.53
(217)
9.63
(245)
6.44 (164)
6.44 (164)
Dimensions are in inches (millimeters)
98
6.44
(154)
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Figure 2. Transmitter with Coplanar Sensor Module and Traditional Flange
PlantWeb Housing
Junction Box Housing
Wireless Housing
Front View
Front View
Front View
Extended Range
External Antenna
External
Antenna
6.93
(176)
9.26
(235)
9.26
(235)
3.40
(86)
1.10
(28)
Side View
90°
10.91
(277)
4.20
(107)
3.40
(86)
1.10
(28)
3.40
(86)
Side View
1.10
(28)
Side View
3.45 (88)
3.46
(87.8)
6.72
(171)
6.06
(155)
7.70
(196)
9.26
(235)
1.63 (41)
1.63 (41)
2.13 (54)
2.13
(54)
Dimensions are in inches (millimeters)
99
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Figure 3. Transmitter with In-Line Sensor Module
PlantWeb Housing
Junction Box Housing
Wireless Housing
Front View
Front View
Front View
Extended Range
External Antenna
4.20 (107)
4.20 (107)
External
Antenna
6.93
(176)
3.46
(87.8)
10.91
(277)
4.20
(107
8.22
(209)
8.22
(209)
Side View
90°
Side View
Side View
5.21 (132)
4.55 (116)
3.45 (88)
6.93
(176)
6.72
(171)
6.06
(155)
8.22
(209)
Dimensions are in inches (millimeters)
100
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Figure 4. Coplanar Mounting Configurations (B4 Bracket)
Pipe Mount
Front View
Panel Mount
Front View
Front View
4.55 (116)
2.58 (66)
6.15
(156)
2.81
(71)
4.70 (120)
3.54 (90)
6.25 (159)
Dimensions are in inches (millimeters)
Figure 5. Traditional Mounting Configurations
Pipe Mount
Pipe Mount (Flat Bracket)
Panel Mount
10.70 (272)
8.18
(208)
2.62
(67)
7.7
(196)
13.03
(331)
0.93
(24)
5.32
(135)
2.62
(67)
3.42
(87)
3.42
(87)
4.85
(123)
7.70 (196)
Dimensions are in inches (millimeters)
101
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Figure 6. In-Line Mounting Configurations (B4 Bracket)
Pipe Mount
Front View
Panel Mount
Side View
2.58
(66)
4.55 (116)
6.15
(156)
6.15
2.81
(71)
6.25
(159)
3.08
(78)
4.72 (120)
6.90 (175)
Dimensions are in inches (millimeters)
Figure 7. Remote Display Mounting Configurations (B4 Bracket)
Pipe Mount
Front View
Panel Mount
Side View
2.33
(59)
5.19 (132)
1.82 (46)
4.48
(114
2.66
(68)
6.90 (175)
6.15
(156)
4.72 (120)
3.08
(78)
Dimensions are in inches (millimeters)
102
6.24 (158)
2.66
(68)
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Figure 8. Rosemount 3051SFA Annubar Flowmeter
Rosemount 3051SFA Annubar Flowmeter(1)
Front View
Side View
Top View
D
C
B
A
Dimensions are in inches (millimeters)
(1) The Pak-Lok Annubar model is available up to 600# ANSI (1440 psig at 100 °F (99 bar at 38 °C)).
Table 16. 3051CFA Annubar Flowmeter Dimensional Data
Sensor Size
A (Max)
1
2
3
7.50 (190.5)
9.25 (235.0)
12.00 (304.8)
B (Max)
C (Max)
16.03 (407.2)
9.00 (228.6)
17.78 (451.6)
9.00 (228.6)
20.53 (521.5)
9.00 (228.6)
Dimensions are in inches (millimeters)
D (Max)
6.90 (175.3)
6.90 (175.3)
6.90 (175.3)
103
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Figure 9. Rosemount 3051SFC Compact Orifice Flowmeter
Rosemount 3051SFC Compact Orifice Flowmeter
Orifice Plate Front View
Orifice Plate Side View
Orifice Plate Top View
Compact Orifice Plate
(Primary Element Type code P)
E
D
B
C
A
F
1.13 (28.7)
(Primary Element Type code C)
Conditioning Orifice Plate
E
D
B
A
C
F
1.13 (28.7)
Dimensions are in inches (millimeters)
Table 17. Dimensional Drawings(1)
Primary(1)
Element Type
A
B
Type P and C
5.62 (143)
Transmitter
Height + A
(1) Measurement in inches (millimeters).
104
Transmitter
Height
7.70 (196)
C
D
E
F
7.75 (197) - closed
8.25 (210) - open
6.00 (152) - closed
6.25 (159) - open
10.2 (257.8) - closed
10.4 (264.2) - open
Max of 6.7 (71)
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Figure 10. Rosemount 3051SFP Integral Orifice Flowmeter
Rosemount 3051SFP Integral Orifice Flowmeter
Front View
Bottom View
Side View
11.9
(302.3)
8.8 (223.46)
7.7 (195.6)
Flow
5.3
(134.14)
B.D.(2)
K(1) Downstream
J Upstream
Dimensions are in inches (millimeters)
Line Size
Dimension
J (Beveled/Threaded pipe ends)
J (RF slip-on, RTJ slip-on, RF-DIN slip on)
J (RF 150#, weld neck)
J (RF 300#, weld neck)
J (RF 600#, weld neck)
K (Beveled/Threaded pipe ends)
K (RF slip-on, RTJ slip-on, RF-DIN slip on)(1)
K (RF 150#, weld neck)
K (RF 300#, weld neck)
1/2-in.
(15 mm)
12.54 (318.4)
12.62 (320.4)
14.37 (364.9)
14.56 (369.8)
14.81 (376.0)
5.74 (145.7)
5.82 (147.8)
7.57 (192.3)
7.76 (197.1)
1-in. (25 mm)
11/2-in. (40 mm)
20.24 (514.0)
20.32 (516.0)
22.37 (568.1)
22.63 (574.7)
22.88 (581.0)
8.75 (222.2)
8.83 (224.2)
10.88 (276.3)
11.14 (282.9)
28.44 (722.4)
28.52 (724.4)
30.82 (782.9)
31.06 (789.0)
31.38 (797.1)
11.91 (302.6)
11.99 (304.6)
14.29 (363.1)
14.53 (369.2)
(1) Downstream length shown here includes plate thickness of 0.162-in. (4.11 mm).
105
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Figure 11. Rosemount 3051SAL Liquid Level Transmitter
Side View
Flush Flanged Configuration
Front View
Extended Flanged Configuration
5.21 (132)
4.20 (107)
4.20 (107)
4.55 (116)
7.09
9.65
(180) 8.53 (245)
(217)
E
D
A
A
H
B
C
H
Extension
2, 4, or 6 (51, 102, or 152)
Dimensions are in inches (millimeters)
Class
ASME B16.5 (ANSI) 150
ASME B16.5 (ANSI) 300
ASME B16.5 (ANSI) 600
DIN 2501 PN 10–40
DIN 2501 PN 25/40
DIN 2501 PN 10/16
Pipe
Size
2 (51)
3 (76)
4 (102)
2 (51)
3 (76)
4 (102)
2 (51)
3 (76)
DN 50
DN 80
DN 100
DN 100
Flange
Thickness A
Bolt Circle
Diameter B
Outside
Diameter C
No. of
Bolts
Bolt Hole
Diameter
Extension
Diameter(1) D
E
H
0.69 (18)
0.88 (22)
0.88 (22)
0.82 (21)
1.06 (27)
1.19 (30)
1.00 (25)
1.25 (32)
20 mm
24 mm
24 mm
20 mm
4.75 (121)
6.0 (152)
7.5 (191)
5.0 (127)
6.62 (168)
7.88 (200)
5.0 (127)
6.62 (168)
125 mm
160 mm
190 mm
180 mm
6.0 (152)
7.5 (191)
9.0 (229)
6.5 (165)
8.25 (210)
10.0 (254)
6.5 (165)
8.25 (210)
165 mm
200 mm
235 mm
220 mm
4
4
8
8
8
8
8
8
4
8
8
8
0.75 (19)
0.75 (19)
0.75 (19)
0.75 (19)
0.88 (22)
0.88 (22)
0.75 (19)
0.88 (22)
18 mm
18 mm
22 mm
18 mm
N/A
2.58 (66)
3.5 (89)
N/A
2.58 (66)
3.5 (89)
N/A
2.58 (66)
N/A
66 mm
89 mm
89 mm
3.6 (92)
5.0 (127)
6.2 (158)
3.6 (92)
5.0 (127)
6.2 (158)
3.6 (92)
5.0 (127)
4.0 (102)
5.4 (138)
6.2 (158)
6.2 (158)
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
7.65 (194)
7.65 (194)
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
(1) Tolerances are 0.040 (1,02), –0.020 (0,51).
106
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
ACCESSORIES
Engineering Assistant Software Packages
Rosemount Engineering Assistant (EA)
Software Packages
The Rosemount Engineering Assistant software supports flow
configuration for the 3051S MultiVariable and 3051S FOUNDATION
fieldbus Fully Compensated Mass Flow Block (H01 option). The
package is available with or without modem and connecting
cables. All configurations are packaged separately.
For best performance of the EA Software, the following computer
hardware and software is recommended:
Minimum System Requirements for Engineering
Assistant 6 for the 3051SMV
• Pentium-grade Processor: 500MHz or faster
• Operating System: Microsoft Windows 2000 (32-bit), Windows
XP Professional (32-bit), or Windows 7 (32-bit)
• 256 MB RAM
• 100 MB of available hard disk space
• RS232 serial port or USB port (for use with HART modem)
Code
Product Description
EA
Code
Engineering Assistant Software Program
Software Media
2
3
Code
EA Rev. 5 (Compatible with 3095, 3051S FOUNDATION
fieldbus, and 333)
EA Rev. 6 (Compatible with 3051SMV only)
Language
E
Code
English
Modem and Connecting Cables
0
H
B
C
Code
None
Serial Port HART Modem and Cables
USB Port HART Modem and Cables
FOUNDATION fieldbus PCM-CIA Interface Card and Cables
License
N1
Single PC license
N2
Site license
Typical Model Number: EA
2
E
0
N1
• CD-ROM
Accessories
NOTE
Engineering Assistant version 6.1 or later requires the use of
Microsoft® .NET Framework version 2.0 or later. If .NET version
2.0 is not currently installed, the software will be automatically
installed during the Engineering Assistant installation. Microsoft
.NET version 2.0 requires an additional 200 MB of disk space.
Minimum System Requirements for Engineering
Assistant 5.5.1 for the 3051S FOUNDATION fieldbus with
Fully Compensated Mass Flow Block (H01 option)
Item Description
Part Number
Serial Port HART Modem and Cables Only
USB Port HART Modem and Cables Only(1)
FOUNDATION fieldbus PCM-CIA Interface
Card and Cables Only
Long-life Power Module for Wireless option
03095-5105-0001
03095-5105-0002
03095-5108-0001
00753-9220-0001
(1) Supported by Snap-On EA with AMS Device Manager version 6.2
or higher.
• PC Compatible Pentium 400 or above
• Operating System: Windows XP Professional (32-bit) or
Windows Vista (32-bit)
• 256 MB RAM
• 535 MB free Hard disk space
• RS232 serial port or USB port (for use with HART modem)
• CD-ROM
107
Product Data Sheet
00813-0100-4801, Rev PA
April 2011
Rosemount 3051S Series
Standard Terms and Conditions of Sale can be found at www.rosemount.com/terms_of_sale
The Emerson logo is a trade mark and service mark of Emerson Electric Co.
Rosemount, Annubar, SuperModule, and the Rosemount logotype are registered trademarks of Rosemount Inc.
PlantWeb is a mark of one of the Emerson Process Management companies.
Instrument Toolkit, Saturn, MultiVariable, and Coplanar are trademarks of Rosemount Inc.
Eurofast and Minifast are registered trademarks of Turck Inc.
HART and WirelessHART are registered trademarks of the HART Communications Foundation.
ASP is a trademark of the Emerson Process Management companies.
Syltherm, Dow Corning, and D.C. are registered trademarks of Dow Corning Co.
Neobee M-20 is a registered trademark of Stephan Chemical Co.
FOUNDATION fieldbus is a trademark of the Fieldbus Foundation.
All other marks are the property of their respective owners.
© 2011 Rosemount, Inc. All rights reserved.
Emerson Process Management
Rosemount Measurement
8200 Market Boulevard
Chanhassen MN 55317 USA
Tel (USA) 1 800 999 9307
Tel (International) +1 952 906 8888
Fax +1 952 906 8889
00813-0100-4801 Rev PA, 4/11
Emerson Process Management
Blegistrasse 23
P.O. Box 1046
CH 6341 Baar
Switzerland
Tel +41 (0) 41 768 6111
Fax +41 (0) 41 768 6300
Emerson FZE
P.O. Box 17033
Jebel Ali Free Zone
Dubai UAE
Tel +971 4 811 8100
Fax +971 4 886 5465
Emerson Process Management Asia Pacific
Pte Ltd
1 Pandan Crescent
Singapore 128461
Tel +65 6777 8211
Fax +65 6777 0947
Service Support Hotline : +65 6770 8711
Email : [email protected]
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF