Domestic Gas Boiler Guide
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:33 Page 1
climate of innovation
Domestic Gas Boiler Guide
Heating systems
Industrial systems
Refrigeration systems
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:33 Page 2
Introduction
Clean, efficient, reliable the economical gas heating system
When it comes to convenient heat generation with natural gas, Viessmann has various technologies to offer
that can satisfy a wide range of demands: whether for new build or modernisation, a flat or a detached house, or
even for major housing developments.
Condensing technology protects the climate and the environment
All our boilers meet the requirements demanded by efficient condensing technology, i.e. 98 percent or more of
the energy spent is converted into heat. With such unbeatably high levels of efficiency, everyone who uses a
gas condensing boiler is making a positive contribution to protecting the climate and the environment.
Innovative technology such as the new gas adsorption heating appliance reduces gas consumption by a further
25 percent compared to conventional condensing technology, saving fuel, reducing emissions still further and
making heating with gas even more efficient.
Futureproof heating technology protects resources
Viessmann gas condensing boilers are already prepared for the future. Thanks to their combustion controller,
these boilers adjust automatically to various gas types - including biogas mixtures. As a result, these heating
systems meet the demand for sustainable heating technologies that are able to conserve natural resources.
Choosing gas central heating also means there’s no need for a fuel store in the house. These compact
appliances use space efficiently, leaving you with extra space in your utility room or cellar.
Solar technology uses free solar energy
Every new heating system, nowadays, should also be able to work with solar collectors to benefit from free solar
energy. All Viessmann boilers are set up for this right now.
Viessmann system design guarantees that all components work together perfectly, right down to the convenient
control unit - even via the internet using an app that does everything you could ask of it.
This brochure provides information on our current range of appliances and plenty of other details - from
accessories and technical specifications to contact information.
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:33 Page 3
Contents
2/3
Vitodens 200 series
from page 4
Gas fired condensing boilers with 5-inch colour touchscreen
control, energy cockpit, up to 1:20 modulation range and
minimum output 1.6 kW
Vitodens 100 series
from page 10
Gas fired condensing boilers with compact dimensions,
low weight and quiet operation, the Vitodens 100 series will
integrate effortlessly into any living space
Vitodens 050-W
from page 16
Gas fired condensing boiler offering excellent
heating and DHW convenience with a particularly
advantageous price/performance ratio
Installation accessories
from page 18
Information on cylinders, including the Viessmann
4-pipe system, flue options and controls
Viessmann Academy
from page 28
See our range of courses available and contact
us to book a place
Contact us
from page 30
Useful contact details for all departments
Technical specification
Detailed boiler technical specifications
from page 32
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:33 Page 4
Vitodens 242-F Solar DHW Storage
1.9 to 26 kW
2
w yea
ar r c
ra o
nt mp
y a re
s s he
ta ns
nd iv
ar e
d
Gas condensing
technology
VITODENS 242-F SOLAR DHW STORAGE
This storage combined floor standing condensing boiler is designed specifically for direct connection to a solar thermal system.
Incorporating three technologies in one; gas condensing boiler, DHW cylinder and solar control package, for where space is at a premium
High DHW convenience
For particularly high DHW convenience, the gas
condensing boiler is equipped with a dual mode
enamelled DHW loading cylinder with 170 litres
capacity. The water heated to the required
temperature is continually charged and therefore
immediately available. Sensors ensure uniform
temperature heating. In the event of higher DHW
demand, the MatriX cylinder burner automatically
starts and maintains the required water temperature.
low maintenance costs: All components are accessible
from the front, no side clearance for servicing is
required. When controlling the Vitodens 242-F via
ViCare or the Vitotrol Plus app, the contractor can
automatically be notified in the event of a fault.
Automatic combustion control reduces costs
All Viessmann gas condensing boilers feature the
integral Lambda Pro Control Plus combustion controller.
It automatically adapts to the quality of different gas
types (natural gas E/L, LPG, biogas) and ensures
consistently high energy efficiency. Lambda Pro Control
Plus helps to keep maintenance costs down.
Cylinder Loading System (CLS)
Most unvented cylinders use a heating coil to heat up
the cylinder. The CLS technology replaces the coil
with a plate heat exchanger. A DHW pump circulates
the cold water from the bottom of the cylinder,
through the plate heat exchanger and puts the hot
water back to the top of the cylinder.
Convenient control via app
Controlling the heating centre is particularly
convenient via app and the Vitoconnect 100 WiFi
adaptor. This establishes the connection to the home
router and enables access to the Vitodens 242-F via
the internet from a smartphone or tablet computer.
The ViCare app controls one heating circuit; for up to
three heating circuits, use the Vitotrol Plus app.
Extremely easy to maintain
By selecting this boiler, the user will also benefit from
Cylinder Loading System (CLS)
Cylinder contents
Take advantage of these benefits
n Gas condensing storage combi boiler with
integral solar cylinder, solar coverage: > 50 %
n Easy to operate Vitotronic control unit with 5
inch colour touchscreen
n Control via app and internet (with optional
Vitoconnect 100 WiFi adaptor)
n High heating and DHW convenience including
solar integration
n MatriX cylinder burner with Lambda Pro Control
combustion controller for permanently high
efficiency and clean combustion
n With a floor area of just 0.4 m², this storage
combi boiler takes up only a relatively small
amount of space, so can fit into any recess.
n Combined PRV and condensate connection, for
fast and simple installation
n Energy efficiency class: A
n Energy efficiency class, DHW heating: A
10°C
0
60°C
2
4
6
8
Heating up time [min]
10
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:33 Page 5
Boilers and accessories
4/5
Boilers
Part No.
Description
B2UB060 Vitodens 242-F Heating Tower 19 kW
B2UB061 Vitodens 242-F Heating Tower 26 kW
7348552 Standard top connection set
7347985 Standard RH or LH side connection set
Controls
7141709 Vitotrol 100 room thermostat
7170149 Vitotrol 100 UTA programmable room thermostat 24h analogue
7408012 Room temperature sensor
5 inch colour touchscreen control with
energy cockpit (see page 26)
Z008341 Vitotrol 200A remote control with LCD display for 1 heating circuit (only with Vitotronic 200)
Z011471 Vitotrol 200 RF pack 1 (includes RF control and receiver) (only in conjunction with weather compensation)
Z011219 Vitotrol 200 RF remote control with LCD display (only in conjunction with weather compensation)
7455213 Wireless outdoor sensor to be used with Vitotrol 200/300 receiver unit (ordered separately)
7456538 Repeater (optional signal booster) for Vitotrol 200 RF (only in conjunction with weather compensation)
Z011472 Wireless pack 2 (Vitotrol 200 RF, receiver unit, outdoor sensor and Vitotronic 200)
Z011413 Vitotrol 300/200 RF receiver unit (only in conjunction with weather compensation)
Z011410 Vitotrol 300 RF RC with table stand (only in conjunction with weather compensation)
Z011412 Vitotrol 300 RF RC with wall mount (only in conjunction with weather compensation)
Z011962 Vitotrol 300 RF RC with table stand and receiver (only in conjunction with weather compensation)
Z011963 Vitotrol 300 RF RC with wall mount and receiver (only in conjunction with weather compensation)
Z008342 Vitotrol 300A remote control with LCD display for up to 3 heating circuits (only with Vitotronic 200)
7438537 Room temperature sensor (optional for Vitotrol 300A only)
7459131 Vitotronic 100 HC1B const temp, no programmer
7570996 Vitotronic 100 HC2B const temp, with 7 day programmer
7661470 Vitotronic 200 HO2B weather compensated controller
7452091 Extension EA1 - wall mounted extension of up to 5 different in and output signals: 1 analogue 0-10 V,
3 digital inputs:1 potential free output
7452092 Extension AM1 - function extensions wall mounted to control up to 2 pumps, i.e. DHW secondary
circulation pump, pump for DHW heating, CH pump without mixer
Flues
7441467 Std 1 m horizontal flue kit Ø 60/100 mm (1000 mm terminal, 87° bend)
7373230 SC vertical flue terminal Ø 60/100 mm
7373227 SC 45° flue elbow Ø 60/100 mm (pair)
7373226 SC 45° flue elbow Ø 60/100 mm (pair)
7373226 SC 87° flue elbow Ø 60/100 mm
7373225 SC 1.95 m flue extension pipe Ø 60/100 mm
7373224 SC 1 m flue extension pipe Ø 60/100 mm
7373223 SC 0.5 m flue extension pipe Ø 60/100 mm
7176762 SC flue mounting clip Ø 100 mm
7667546 Balanced flue pipe 60/100, 3 m NEW
7667547 Wall terminal 60/100 1.75 m
Cylinder in 242-F includes
solar coil
7337276 Terminal guard
7373238 Plume management kit
7373266 Flue bend 45° Ø 60 mm (pair)
7373267 Flue bend 87° Ø 60 mm
7373268 Plume kit 1 m flue extension Ø 60 mm
7452499 Roof tile lead Ø 125 red (for 60/100 mm flue system)
7452500 Roof tile lead Ø 125 red (for 60/100 mm flue system)
7452501 Roof tile lead Ø 160 black (for 80/125 mm flue system)
7452502 Roof tile lead Ø 160 red (for 80/125 mm flue system)
7452503 Roof Flashing Kit D=200
7426187 Flat Roof Collar Alu D=125 H=250 S
ZK00028 Chimney flue kit 60/100 - 12.5 m / room sealed
ZK00029 Chimney flue kit Ø 60/100 mm - 12.5 m / open flued (for longer flue lengths upgrade to Ø 80/125 mm)
7502602 Chimney kit for recess installation 60/100 with flexi 60 mm
7502603 Chimney kit for recess installation 60/100 with flexi 80 mm
7590109 Open flued water protection cap
7373240 Flue adaptor 60/100 to 80/125 mm
For all other accessories please see page 25
10 Year Warranty
on all stainless steel heat exchangers for
gas condensing boilers up to 150 kW
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:33 Page 6
Vitodens 222-F DHW Storage
1.8 to 35 kW
5
3
ye w yea
ar arr r c
s i an om
f
Tr fitt ty a pre
ai ed s s he
ne b t n
d y a an siv
In
d
st Vie ard e
al s
le sm
r
an
n
Gas condensing
technology
VITODENS 222-F DHW STORAGE
This storage combined floor standing condensing boiler is designed specifically for modernising heating systems and replacing
older gas fired boilers and DHW cylinders
Alternative solutions for different degrees of
water hardness
The enamelled loading cylinders with 100 litres or 130
litres capacity (type B2TB) provide a high level of DHW
convenience. Where drawing hot water is concerned, this
volume is comparable to a separate 350 litre DHW
cylinder. The water heated to the required temperature
continually charges the loading cylinder and is therefore
immediately available. Sensors ensure a uniform
temperature.
Automatic combustion control reduces costs
All Viessmann gas condensing boilers feature the
integral Lambda Pro Control Plus combustion
controller. It automatically adapts to the different
properties of different gas types (natural gas E/L, LPG,
biogas) and ensures consistently high energy
efficiency. Lambda Pro Control Plus helps to keep
maintenance costs down.
Convenient control via app
Controlling the heating centre is particularly
convenient via app and the Vitoconnect 100 WiFi
adaptor. This establishes the connection to the home
router and enables access to the Vitodens 222-F via
the internet from a smartphone or tablet computer.
The ViCare app controls one heating circuit; for up to
three heating circuits, use the Vitotrol Plus app.
Extremely easy to maintain
By selecting this boiler, the user will also benefit from
low maintenance costs: All components are accessible
from the front, no side clearance for servicing is
required. When controlling the Vitodens 222-F via
ViCare or the Vitotrol Plus app, the contractor can
automatically be notified in the event of a fault.
Cylinder Loading System (CLS)
Most unvented cylinders use a heating coil to heat up
the cylinder. The CLS technology replaces the coil with
a plate heat exchanger. A DHW pump circulates the
cold water from the bottom of the cylinder, through the
plate heat exchanger and puts the hot water back to
the top of the cylinder.
Cylinder Loading System (CLS)
Cylinder contents
Take advantage of these benefits
n Floorstanding gas condensing storage combi
boiler in standard kitchen unit dimensions
n High level of DHW convenience thanks to an
integral loading cylinder
n Durable and efficient thanks to the Inox-Radial
heat exchanger
n Power saving high efficiency pump
n Easy to operate Vitotronic control unit with 5
inch colour touchscreen
n Control via app and internet (with optional
Vitoconnect 100 WiFi adaptor)
n Combined PRV and condensate connection, for
fast and simple installation
n Energy efficiency class: A
n Energy efficiency class, DHW heating: A
10°C
0
60°C
2
4
6
8
Heating up time [min]
10
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:33 Page 7
Boilers and accessories
6/7
Boilers
Part No.
Description
B2TB111 Vitodens 222-F Storage combi (Const temp & 7-day programmer) 19 kW
B2TB112 Vitodens 222-F Storage combi (Const temp & 7-day programmer) 26 kW
B2TB113 Vitodens 222-F Storage combi (Const temp & 7-day programmer) 35 kW
B2TB115 Vitodens 222-F Storage combi (Weather comp) 19 kW
B2TB116 Vitodens 222-F Storage combi (Weather comp) 26 kW
B2TB117 Vitodens 222-F Storage combi (Weather comp) 35 kW
7348566 Standard top connection set
7350854 Standard RH or LH side connection set
5 inch colour touchscreen control with
energy cockpit (see page 26)
Controls
7141709 Vitotrol 100 room thermostat
7170149 Vitotrol 100 UTA programmable room thermostat 24h analogue
Z007691 Vitotrol 100 UTDB programmable room thermostat - 7 day, single channel
Z007692 Vitotrol 100 UTDB RF wireless programmable room thermostat - 7 day, single channel
7408012 Room temperature sensor
Z008341 Vitotrol 200A remote control with LCD display for 1 heating circuit (only with Vitotronic 200)
Z011471 Vitotrol 200 RF pack 1 (includes RF control and receiver) (only in conjunction with weather compensation)
Z011472 Wireless pack 2 (Vitotrol 200 RF, receiver unit, outdoor sensor and Vitotronic 200)
Z011219 Vitotrol 200 RF remote control with LCD display (only in conjunction with weather compensation)
7455213 Wireless outdoor sensor to be used with Vitotrol 200/300 receiver unit (ordered separately)
7456538 Repeater (optional signal booster) for Vitotrol 200 RF (only in conjunction with weather compensation)
Z011472 Wireless pack 2 (Vitotrol 200 RF, receiver unit, outdoor sensor and Vitotronic 200)
Z011413 Vitotrol 300 RF RC with table stand and receiver (only in conjunction with weather compensation)
Z011410 Vitotrol 300 RF RC with table stand (only in conjunction with weather compensation)
Z011412 Vitotrol 300 RF RC with wall mount (only in conjunction with weather compensation)
Z011962 Vitotrol 300 RF RC with table stand and receiver (only in conjunction with weather compensation)
Z011963 Vitotronic 100 HC1B const temp, no programmer
7570996 Vitotrol 300 RF RC with wall mount and receiver (only in conjunction with weather compensation)
Z008342 Vitotrol 300A remote control with LCD display for up to 3 heating circuits (only with Vitotronic 200)
7438537 Room temperature sensor (optional for Vitotrol 300A only)
7459131 Vitotronic 100 HC1B const temp, no programmer
7570996 Vitotronic 100 HC2B const temp, with 7 day programmer
7661470 Vitotronic 200 HO2B weather compensated controller
7452091 Extension EA1 - wall mounted extension of up to 5 different in and output signals: 1 analogue 0-10 V,
3 digital inputs:1 potential free output
7452092 Extension AM1 - function extensions wall mounted to control up to 2 pumps, i.e. DHW secondary
circulation pump, pump for DHW heating, CH pump without mixer
Flues
7441467 Std 1 m horizontal flue kit Ø 60/100 mm (1000 mm terminal, 87° bend)
Two cylinder sizes available
19/26 kW models 100 litres
35 kW model 130 litres
7373230 SC vertical flue terminal Ø 60/100 mm
7373227 SC 45° flue elbow Ø 60/100 mm (pair)
7373226 SC 87° flue elbow Ø 60/100 mm
7373225 SC 1.95 m flue extension pipe Ø 60/100 mm
7373224 SC 1 m flue extension pipe Ø 60/100 mm
7373223 SC 0.5 m flue extension pipe Ø 60/100 mm
7176762 SC flue mounting clip Ø 100 mm
7667546 Balanced flue pipe 60/100, 3 m NEW
7667547 Wall terminal 60/100, 1.75 m
7337276 Terminal guard
7373238 Plume management kit
7373266 Flue bend 45° Ø 60 mm (pair)
7373267 Flue bend 87° Ø 60 mm
7373268 Plume kit 1 m flue extension Ø 60 mm
7246572 Fixing clamps - 60 mm
7452499 Roof tile lead Ø 125 black (for 60/100 mm flue system)
7452500 Roof tile lead Ø 125 red (for 60/100 mm flue system)
7452501 Roof tile lead Ø 160 black (for 80/125 mm flue system)
7452502 Roof tile lead Ø 160 red (for 80/125 mm flue system)
7452503 Roof Flashing Kit D=200
7426187 Flat Roof Collar Alu D=125 H=250 S
ZK00028 Chimney flue kit 60/100 - 12.5 m / room sealed
ZK00029 Chimney flue kit Ø 60/100 mm - 12.5 m / open flued (for longer flue lengths upgrade to Ø 80/125 mm)
7502602 Chimney kit for recess installation 60/100 with flexi 60 mm
7502603 Chimney kit for recess installation 60/100 with flexi 80 mm
7590109 Open flued water protection cap
7373240 Flue adaptor 60/100 to 80/125 mm
For all other accessories please see page 25
10 Year Warranty
on all stainless steel heat exchangers for
gas condensing boilers up to 150 kW
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:33 Page 8
Vitodens 200-W Combi and System
1.8 to 35 kW
5
3
ye w yea
ar arr r c
s i an om
f
Tr fitt ty a pre
ai ed s s he
ne b t n
d y a an siv
In
d
st Vie ard e
al s
le sm
r
an
n
Gas condensing
technology
VITODENS 200-W COMBI AND SYSTEM
Wall mounted gas fired condensing boiler, with modulating MatriX cylinder burner and Inox-Radial heat exchanger, for open and
balanced flue operation.
Take advantage of these benefits
n Up to 98 percent of the fuel used is converted
into heat
n Quiet operation thanks to low fan speed
n Compact dimensions, only 450 mm wide
n 1:20 modulation range (35 kW)
n Easy to operate Vitotronic control unit with 5
inch colour touchscreen
n Control via app and internet (with optional
Vitoconnect 100 WiFi adaptor)
n Optionally available as combi (type BK2B) or
system boiler (type B2HB)
n Also available: 49/60, 80-150 kW
n Energy efficiency class: A
n Combined PRV and condensate connection, for
fast and simple installation
Automatic combustion control reduces costs
The integral Lambda Pro Control Plus combustion
controller automatically adapts to the properties
of different gas types (natural gas or LPG) and
ensures consistently high energy efficiency.
Lambda Pro Control Plus helps to keep
maintenance costs down.
Convenient control via app
Controlling the heating centre is particularly
convenient via app and the Vitoconnect 100 WiFi
adaptor. This establishes the connection to the home
router and enables access to the Vitodens 200-W via
the internet from a smartphone or tablet computer.
The ViCare app controls one heating circuit; for up to
three heating circuits, use the Vitotrol Plus app.
Extremely easy to maintain
By selecting this boiler, the user will also benefit from
low maintenance costs: All components are
accessible from the front, no side clearance for
servicing is required. When controlling the Vitodens
200-W via ViCare or the Vitotrol Plus app, the
contractor can automatically be notified in the event
of a fault.
Available as a system or combi boiler
The Vitodens 200-W is optionally available as a
system boiler with separate DHW heating or, as a
combi boiler with an output of up to 35 kW and an
integral instantaneous water heater.
Viessmann 4-pipe system
Viessmann Vitodens system boilers up to
35 kW installed together with a Vitocell 200
or 300 unvented cylinder are the perfect
combination to meet G3 building regulations
without the need for an energy cut-off valve
and cylinder overheat thermostat; these are
integrated into the boiler (see page 18).
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:33 Page 9
Boilers and accessories
8/9
Boilers
Part No.
Description
Part No.
Vitodens 200-W System boiler
Description
Vitodens 200-W Combi boiler
B2HB406 With Vitotronic 100 const temp 19 kW
B2KB075
With Vitotronic 100 const temp 26 kW
B2HB407 With Vitotronic 100 const temp 26 kW
B2KB076
With Vitotronic 100 const temp 30 kW
B2HB408 With Vitotronic 100 const temp 30 kW
B2KB077
With Vitotronic 100 const temp 35 kW
B2HB409 With Vitotronic 100 const temp 35 kW
B2KB078
With Vitotronic 200 weather comp 26 kW
B2HB410 With Vitotronic 200 weather comp 19 kW
B2KB079
With Vitotronic 200 weather comp 30 kW
B2HB411 With Vitotronic 200 weather comp 26 kW
B2KB080
With Vitotronic 200 weather comp 35 kW
B2HB412 With Vitotronic 200 weather comp 30 kW
5 inch colour touchscreen control with
energy cockpit (see page 26)
B2HB413 With Vitotronic 200 weather comp 35 kW
Controls
7141709 Vitotrol 100 room thermostat
7170149 Vitotrol 100 UTA programmable room thermostat 24h analogue
Z007691 Vitotrol 100 UTDB programmable room thermostat - 7 day, single channel
Z007692 Vitotrol 100 UTDB RF wireless programmable room thermostat - 7 day, single channel
7408012 Room temperature sensor
Z008341 Vitotrol 200A remote control with LCD display for 1 heating circuit (only with Vitotronic 200)
Z011471 Vitotrol 200 RF pack 1 (includes RF control and receiver) (only in conjunction with weather compensation)
Z011472 Wireless pack 2 (Vitotrol 200 RF, receiver unit, outdoor sensor and Vitotronic 200)
Z011219 Vitotrol 200 RF remote control with LCD display (only in conjunction with weather compensation)
7455213 Wireless outdoor sensor to be used with Vitotrol 200/300 receiver unit (ordered separately)
7456538 Repeater (optional signal booster) for Vitotrol 200 RF (only in conjunction with weather compensation)
Z011472 Wireless pack 2 (Vitotrol 200 RF, receiver unit, outdoor sensor and Vitotronic 200)
Z011413 Vitotrol 300/200 RF receiver unit (only in conjunction with weather compensation)
Z011410 Vitotrol 300 RF RC with table stand (only in conjunction with weather compensation)
Z011412 Vitotrol 300 RF RC with wall mount (only in conjunction with weather compensation)
Z011962 Vitotrol 300 RF RC with table stand and receiver (only in conjunction with weather compensation)
Z011963 Vitotrol 300 RF RC with wall mount and receiver (only in conjunction with weather compensation)
Z008342 Vitotrol 300A remote control with LCD display for up to 3 heating circuits (only with Vitotronic 200)
7438537 Room temperature sensor (optional for Vitotrol 300A only)
7459131 Vitotronic 100 HC1B const temp, no programmer
7570996 Vitotronic 100 HC2B const temp, with 7 day programmer
7661470 Vitotronic 200 HO2B weather compensated controller
200-W showing components
7452091 Extension EA1 - wall mounted extension of up to 5 different in and output signals: 1 analogue 0-10 V,
3 digital inputs:1 potential free output
7452092 Extension AM1 - function extensions wall mounted to control up to 2 pumps, i.e. DHW secondary
circulation pump, pump for DHW heating, CH pump without mixer
Flues
7411961 Telescopic flue kit Ø 60/100 mm
7441467 Std 1 m horizontal flue kit Ø 60/100 mm (1000 mm terminal, 87° bend)
7373230 SC vertical flue terminal Ø 60/100 mm
7373227 SC 45° flue elbow Ø 60/100 mm (pair)
7373226 SC 87° flue elbow Ø 60/100 mm
7373225 SC 1.95 m flue extension pipe Ø 60/100 mm
7373224 SC 1 m flue extension pipe Ø 60/100 mm
7373223 SC 0.5 m flue extension pipe Ø 60/100 mm
7176762 SC flue mounting clip Ø 100 mm
7667546 Balanced flue pipe 60/100, 3 m NEW
7667547 Wall terminal 60/100, 1.75 m
7337276 Terminal guard
7373238 Plume management kit
7373266 Flue bend 45° Ø 60 mm (pair)
7373267 Flue bend 87° Ø 60 mm
7373268 Plume kit 1 m flue extension Ø 60 mm
7246572 Fixing clamps - 60 mm
7452499 Roof tile lead Ø 125 black (for 60/100 mm flue system)
7452500 Roof tile lead Ø 125 red (for 60/100 mm flue system)
7452501 Roof tile lead Ø 160 black (for 80/125 mm flue system)
7452502 Roof tile lead Ø 160 red (for 80/125 mm flue system)
7452503 Roof Flashing Kit D=200
7426187 Flat Roof Collar Alu D=125 H=250 S
ZK00028 Chimney flue kit 60/100 - 12.5 m / room sealed
ZK00029 Chimney flue kit Ø 60/100 mm - 12.5 m / open flued (for longer flue lengths upgrade to Ø 80/125 mm)
7502602 Chimney kit for recess installation 60/100 with flexi 60 mm
7502603 Chimney kit for recess installation 60/100 with flexi 80 mm
7590109 Open flued water protection cap
7373240 Flue adaptor 60/100 to 80/125 mm
For all other accessories please see page 25
10 Year Warranty
on all stainless steel heat exchangers for
gas condensing boilers up to 150 kW
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:33 Page 10
Vitodens 111-W DHW Storage
4.7 to 35 kW
Op
tio
5
w yea
n ar r c
to ra o
in nty mp
cr
ea as reh
se sta e n
up nd siv
to ard e
10
ye
ar
s*
Gas condensing
technology
VITODENS 111-W DHW STORAGE
Wall mounted gas fired condensing boiler with integral cylinder for the highest DHW convenience.
The Vitodens 111-W is also equipped with a stainless
steel loading cylinder that boasts a 46 litre capacity.
The modulating ratio over the entire output
range is up to 1:6. This high ratio makes these
boilers particularly suitable for use in small
apartments and well insulated buildings. The
user benefits from fewer appliance start-ups
and therefore less operating noise. Because
a lower level of stress is placed upon the
appliance, the service life of components is
consequently extended.
Stainless steel heat exchanger
As is the case with all Viessmann gas
condensing boilers, the Vitodens 111-W are
equipped with stainless steel Inox-Radial heat
exchangers. This technology brings with it an
extremely high efficiency rate of 98 percent and
exceptionally reliable and efficient operation during
its long service life.
Viessmann guarantees the Inox-Radial heat
exchanger for ten years against leaks resulting
from corrosion.
Cylinder Loading System (CLS)
Most unvented cylinders use a heating coil to heat up
the cylinder. The CLS technology replaces the coil
with a plate heat exchanger. A DHW pump circulates
the cold water from the bottom of the cylinder,
through the plate heat exchanger and puts the hot
water back to the top of the cylinder.
* Viessmann Trained Installers can offer their
customers an extended warranty option up to 10
years.
Cylinder Loading System (CLS)
Cylinder contents
Take advantage of these benefits
n Compact dimensions save space, particularly
when installed in a living area
n SEDBUK 2009 seasonal efficiency 89.5%
n Ideal as a replacement for older appliances due
to low installed height and installation space for
adaptation to existing systems
n Low operating noise through extended
modulation ratio
n Modulation ratio: up to 1:6
n Modulating stainless steel cylinder burner
n User friendly control via backlit LCD
touchscreen (option for control via room
thermostats)
n 46 l stainless steel loading cylinder
n Combined PRV and condensate connection, for
fast and simple installation
n Straightforward access from the front, so no
need to leave space at side for maintenance
n Also approved for multiple connections to
stacks in multi storey buildings
10°C
0
60°C
2
4
6
8
Heating up time [min]
10
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:33 Page 11
Boilers and accessories
10/11
Boilers
Part No.
Description
B1LD009 Vitodens 111-W with integrated 46l un-vented cylinder 26 kW
B1LD010 Vitodens 111-W with integrated 46l un-vented cylinder 35 kW
Controls
7141709 Vitotrol 100 room thermostat
7170149 Vitotrol 100 UTA programmable room thermostat 24h analogue
7522678 Analogue time clock
7522677 Analogue time clock
Z007691 Vitotrol 100 UTDB programmable room thermostat - 7 day, single channel
7454528 Digital time clock
7454521 Vitotrol 100 UTA RF 1 channel
7537234 Vitotrol 100 UTDB RF2
The touchscreen improves user
friendliness
The Vitodens 100-W wall mounted
gas condensing boilers are controlled
by the new, backlit LCD touchscreen,
which makes it easy to use and read
in dark environments.
Z013877 Mixer extension kit without Vitotrol 100 Open Therm (OT)
Z013919 Mixer extension kit with one Vitotrol 100 Open Therm (OT)
Z013920 Mixer extension kit with two Vitotrol 100 Open Therm (OT)
ZK02485 Outside temperature sensor for weather compensated operation
Flues
7411961 Telescopic flue kit Ø 60/100 mm
7441467 Std 1 m horizontal flue kit Ø 60/100 mm (1000 mm terminal, 87° bend)
7373230 SC vertical flue terminal Ø 60/100 mm
7373227 SC 45° flue elbow Ø 60/100 mm (pair)
7373226 SC 87° flue elbow Ø 60/100 mm
7373225 SC 1.95 m flue extension pipe Ø 60/100 mm
7373224 SC 1 m flue extension pipe Ø 60/100 mm
7373223 SC 0.5 m flue extension pipe Ø 60/100 mm
7176762 SC flue mounting clip Ø 100 mm
7667546 Balanced flue pipe 60/100, 3 m NEW
7667547 Wall terminal 60/100, 1.75 m
7337276 Terminal guard
7373238 Plume management kit
7373266 Flue bend 45° Ø 60 mm (pair)
7373267 Flue bend 87° Ø 60 mm
7373268 Plume kit 1 m flue extension Ø 60 mm
7246572 Fixing clamps - 60 mm
7452499 Roof tile lead Ø 125 black (for 60/100 mm flue system)
7452500 Roof tile lead Ø 125 red (for 60/100 mm flue system)
7452501 Roof tile lead Ø 160 black (for 80/125 mm flue system)
7452502 Roof tile lead Ø 160 red (for 80/125 mm flue system)
111-W showing components
7452503 Roof Flashing Kit D=200
7426187 Flat Roof Collar Alu D=125 H=250 S
ZK00028 Chimney flue kit 60/100 - 12.5 m / room sealed
ZK00029 Chimney flue kit Ø 60/100 mm - 12.5 m / open flued (for longer flue lengths upgrade to Ø 80/125 mm)
7502602 Chimney kit for recess installation 60/100 with flexi 60 mm
7502603 Chimney kit for recess installation 60/100 with flexi 80 mm
7590109 Open flued water protection cap
7373240 Flue adaptor 60/100 to 80/125 mm
For all other accessories please see page 25
10 Year Warranty
on all stainless steel heat exchangers for
gas condensing boilers up to 150 kW
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:33 Page 12
Vitodens 100-W Combi and System
4.7 to 35 kW
Op
tio
5
w yea
n ar r c
to ra o
in nty mp
cr
ea as reh
se sta e n
up nd siv
to ard e
10
ye
ar
s*
Gas condensing
technology
VITODENS 100-W COMBI AND SYSTEM
With it’s compact dimensions, low weight and quiet operation, the Vitodens 100-W will integrate effortlessly into any living space.
Take advantage of these benefits
n SEDBUK 2009 seasonal efficiency 89.5%
n Ideal as a replacement for older appliances due
to low installed height and installation space for
adaptation to existing systems
n Low operating noise through extended
modulation ratio: up to 1:6
n Modulating stainless steel cylinder burner
n User friendly control via backlit LCD
touchscreen (option for control via room
thermostats)
n Straightforward access from the front, so no
need to leave space at side for maintenance
n Also approved for multiple connections to
stacks in multi storey buildings
n Combined PRV and condensate connection, for
fast and simple installation
boilers particularly suitable for use in small
apartments and well insulated buildings. The
user benefits from fewer appliance start-ups
and therefore less operating noise. Because
a lower level of stress is placed upon the
appliance, the service life of components is
consequently extended.
With their compact dimensions, low weight
and quiet operation, the attractively priced
Vitodens 100-W gas condensing boilers will
integrate effortlessly into any living space.
The modulating ratio over the entire output
range is up to 1:6. This high ratio makes these
The touchscreen improves user
friendliness
The Vitodens 100-W wall mounted gas
condensing boilers are controlled by the new,
backlit LCD touchscreen, which makes it easy to
use and read in dark environments.
Stainless steel heat exchanger
As is the case with all Viessmann gas condensing
boilers, the Vitodens 100-W is equipped with stainless
steel Inox-Radial heat exchangers. This technology
brings with it an extremely high efficiency rate of 98
percent and exceptionally reliable and efficient
operation during its long service life. Viessmann
guarantees the Inox-Radial heat exchanger for ten
years against leaks resulting from corrosion.
Viessmann 4-pipe system
Viessmann Vitodens system boilers up to
35 kW installed together with a Vitocell 200
or 300 unvented cylinder are the perfect
combination to meet G3 building regulations
without the need for an energy cut-off valve
and cylinder overheat thermostat; these are
integrated into the boiler (see page 18).
* Viessmann Trained Installers can offer their
customers an extended warranty option up to 10
years.
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 13
Boilers and accessories
12/13
Boilers
Part No.
Description
B1KC023 Vitodens 100-W Combi boiler 26 kW
B1KC024 Vitodens 100-W Combi boiler 30 kW
B1KC025 Vitodens 100-W Combi boiler 35 kW
B1HC028 Vitodens 100-W System boiler 19 kW
B1HC029 Vitodens 100-W System boiler 26 kW
B1HC030 Vitodens 100-W System boiler 30 kW
B1HC031 Vitodens 100-W System boiler 35 kW
Controls
7141709 Vitotrol 100 room thermostat
7170149 Vitotrol 100 UTA programmable room thermostat 24h analogue
7522678 Analogue time clock
The touchscreen improves user
friendliness
The Vitodens 100-W wall mounted
gas condensing boilers are controlled
by the new, backlit LCD touchscreen,
which makes it easy to use and read
in dark environments.
Z007691 Vitotrol 100 UTDB programmable room thermostat - 7 day, single channel
7511618 Vitotrol 100 OpenTherm programmable room controller, 7 day, single channel (load compensation)
Z007692 Vitotrol 100 UTDB RF wireless programmable room thermostat - 7 day, single channel
7454528 Digital time clock
7454521 Vitotrol 100 UTA RF 1 channel
7537234 Vitotrol 100 UTDB RF2
Z013877 Mixer extension kit without Vitotrol 100 Open Therm (OT)
Z013919 Mixer extension kit with one Vitotrol 100 Open Therm (OT)
Z013920 Mixer extension kit with two Vitotrol 100 Open Therm (OT)
ZK02485 Outside temperature sensor for weather compensated operation
Flues
7411961 Telescopic flue kit Ø 60/100 mm
7441467 Std 1 m horizontal flue kit Ø 60/100 mm (1000 mm terminal, 87° bend)
7373230 SC vertical flue terminal Ø 60/100 mm
7373227 SC 45° flue elbow Ø 60/100 mm (pair)
7373226 SC 87° flue elbow Ø 60/100 mm
7373225 SC 1.95 m flue extension pipe Ø 60/100 mm
7373224 SC 1 m flue extension pipe Ø 60/100 mm
7373223 SC 0.5 m flue extension pipe Ø 60/100 mm
7176762 SC flue mounting clip Ø 100 mm
7667546 Balanced flue pipe 60/100, 3 m NEW
7667547 Wall terminal 60/100, 1.75 m
7337276 Terminal guard
7373238 Plume management kit
7373266 Flue bend 45° Ø 60 mm (pair)
7373267 Flue bend 87° Ø 60 mm
100-W showing components
7373268 Plume kit 1 m flue extension Ø 60 mm
7246572 Fixing clamps - 60 mm
7452499 Roof tile lead Ø 125 black (for 60/100 mm flue system)
7452500 Roof tile lead Ø 125 red (for 60/100 mm flue system)
7452501 Roof tile lead Ø 160 black (for 80/125 mm flue system)
7452502 Roof tile lead Ø 160 red (for 80/125 mm flue system)
7452503 Roof Flashing Kit D=200
7426187 Flat Roof Collar Alu D=125 H=250 S
ZK00028 Chimney flue kit 60/100 - 12.5 m / room sealed
ZK00029 Chimney flue kit Ø 60/100 mm - 12.5 m / open flued (for longer flue lengths upgrade to Ø 80/125 mm)
7502602 Chimney kit for recess installation 60/100 with flexi 60 mm
7502603 Chimney kit for recess installation 60/100 with flexi 80 mm
7590109 Open flued water protection cap
7373240 Flue adaptor 60/100 to 80/125 mm
For all other accessories please see page 25
10 Year Warranty
on all stainless steel heat exchangers for
gas condensing boilers up to 150 kW
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 14
Vitodens 100-W Open Vent
7.9 to 35 kW
Op
tio
5
w yea
n ar r c
to ra o
in nty mp
cr
ea as reh
se sta e n
up nd siv
to ard e
10
ye
ar
s*
Gas condensing
technology
VITODENS 100-W OPEN VENT
Wall mounted gas fired condensing boiler, with modulating MatriX cylinder burner and Inox-Radial heat exchanger, for open and
balanced flue operation.
Take advantage of these benefits
n For natural gas and LPG (conversion kit
part no. 7828769)
n Permissible boiler operating pressure 3 bar
n Modulation ratio of 1:3
n Room thermostatic and weather
compensated control unit options
n Min static head 1 m
With a depth of only 285 mm (340 mm for 35 kW
model) the Vitodens 100-W Open Vent boiler is
perfectly suited for integration into standard kitchen
cupboards. It can also be used in a vast number of other
applications where there is only limited space available.
Inox-Radial heat exchanger
The corrosion-resistant stainless steel Inox-Radial heat
exchanger with particularly strong walls is extremely
durable and achieves efficiency levels of up to 97%.
Quiet in operation
The boiler's special design ensures the very low
operating noise of 39 dB (A) maximum (26 kW)
which is perfectly acceptable even in the kitchen.
Optional weather compensation
With a simple up-grade the Vitodens 100-W
Open Vent can operate in weather compensated
mode without incurring a costly heating system
modification. Weather compensation acts like
an autopilot as it detects outside temperature
changes and automatically adjusts the flow
temperature of the boiler, thus achieving gas
savings of up to 12%.
5 year parts and labour warranty
The Vitodens 100-W Open Vent comes with a
standard 5 year parts and labour warranty. The
stainless steel Inox-Radial heat exchanger features
a 10 year anti corrosion warranty.
Ideal for Y and S plan heating systems
Whilst being specifically designed for open vent
heating systems, the Vitodens 100-W Open Vent is
suitable for sealed systems using an additional
expansion vessel and safety valve. The boiler also
shares the various flue options available for the
Combination and System models of the Vitodens
100-W gas condensing boiler range.
* Viessmann Trained Installers can offer their
customers an extended warranty option up to 10
years.
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 15
Boilers and accessories
14/15
Boilers
Part No.
Description
WB1B316 Vitodens 100-W Compact (Open vent) NG & LPG 13 kW
WB1B317 Vitodens 100-W Compact (Open vent) NG & LPG 16 kW
WB1B318 Vitodens 100-W Compact (Open vent) NG & LPG 19 kW
WB1B319 Vitodens 100-W Compact (Open vent) NG & LPG 26 kW
WB1B491 Vitodens 100-W Compact (Open vent) NG & LPG 35 kW
Controls
7141709 Vitotrol 100 room thermostat
7522677 Analogue time clock
7296063 Digital time switch (plug-in) 2 channel (only in conjunction with weather compensation)
Inox-Radial heat exchanger
7296064 Vitotrol 100 UTA RF wireless plug-in programmable room thermostat, 1 channel, 24h (only in
conjunction with weather compensation)
Z007693 Vitotrol 100 UTDB RF2 wireless plug-in programmable room thermostat, 2 channel, 7 day (only
in conjunction with weather compensation)
Z007933 Weather compensation outdoor sensor (incl DHW demand box)
Flues
7411961 Telescopic flue kit Ø 60/100 mm
7441467 Std 1 m horizontal flue kit Ø 60/100 mm (1000 mm terminal, 87° bend)
7373230 SC vertical flue terminal Ø 60/100 mm
7373227 SC 45° flue elbow Ø 60/100 mm (pair)
7373226 SC 87° flue elbow Ø 60/100 mm
7373225 SC 1.95 m flue extension pipe Ø 60/100 mm
7373224 SC 1 m flue extension pipe Ø 60/100 mm
7373223 SC 0.5 m flue extension pipe Ø 60/100 mm
7176762 SC flue mounting clip Ø 100 mm
7667546 Balanced flue pipe 60/100, 3 m NEW
7667547 Wall terminal 60/100, 1.75 m
7337276 Terminal guard
7373238 Plume management kit
7373266 Flue bend 45° Ø 60 mm (pair)
7373267 Flue bend 87° Ø 60 mm
7373268 Plume kit 1 m flue extension Ø 60 mm
7246572 Fixing clamps - 60 mm
7452499 Roof tile lead Ø 125 black (for 60/100 mm flue system)
7452500 Roof tile lead Ø 125 red (for 60/100 mm flue system)
7452501 Roof tile lead Ø 160 black (for 80/125 mm flue system)
100-W Open Vent showing
components
7452502 Roof tile lead Ø 160 red (for 80/125 mm flue system)
7452503 Roof Flashing Kit D=200
7426187 Flat Roof Collar Alu D=125 H=250 S
ZK00028 Chimney flue kit 60/100 - 12.5 m / room sealed
ZK00029 Chimney flue kit Ø 60/100 mm - 12.5 m / open flued (for longer flue lengths upgrade to Ø 80/125 mm)
7502602 Chimney kit for recess installation 60/100 with flexi 60 mm
7502603 Chimney kit for recess installation 60/100 with flexi 80 mm
7590109 Open flued water protection cap
7373240 Flue adaptor 60/100 to 80/125 mm
For all other accessories please see page 25
10 Year Warranty
on all stainless steel heat exchangers for
gas condensing boilers up to 150 kW
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 16
Vitodens 050-W Combi
5.9 to 35 kW
3
Op yea
tio r c
n t om
o i pr
nc eh
re en
as si
e u ve
p t wa
o 7 rr
ye anty
ar
s*
Gas condensing
technology
VITODENS 050-W COMBI
The Vitodens 050-W wall mounted gas condensing boiler offers excellent heating and DHW convenience with a particularly
advantageous price/performance ratio.
Take advantage of these benefits
n Standard efficiency up to 97% (Hs)
n Highly durable and efficient through
Inox-Radial stainless steel heat exchanger
n Modulating high efficiency stainless steel
cylinder burner
n Easy to operate control with manual power
limitation and provision for connecting
modulating thermostats
n Combined PRV and condensate connection, for
fast and simple installation
n Outstanding DHW convenience through its
integral booster function
n Manual exhaust gas adaption enables
large, maximum flue pipe length without
any decrease in heat output
n Digital user interface with LCD display
n Suitable for weather compensation and/or
n High efficiency A rated pump
open therm control operation
With the Vitodens 050-W, Viessmann now offers
an attractively priced wall mounted gas condensing
boiler with proven quality. An extensive range of
accessories makes the Vitodens 050-W equally
suitable for either new build or modernisation. It is
offered with two DHW output ratings (5.9 to 29
and 8 to 35 kW), as a combi boiler with an integral
instantaneous water heater. An electronic boiler
control unit for thermostatic mode and weather
compensated mode is already integrated into the
Vitodens 050-W, along with a frost stat. The
outside temperature sensor is available as an
accessory.
Quiet and compact
The Vitodens 050-W features a particularly low
level of operating noise and its components are
accessible from the front for ease of service and
maintenance. With a height of only 707 mm, the
Vitodens 050-W is one of the smallest wall
mounted boilers in its class. Its compact
dimensions recommend it as a replacement for
outdated boilers in multi storey buildings –
including up to five boilers on different floors
connected to one vertical flue system.
Inox-Radial heat exchanger and cylinder
burner made from stainless steel
The high quality stainless steel Inox-Radial heat
exchanger efficiently converts the supplied energy
into heat. Its efficiency (to DIN) is 97 percent (Hs)
[gross cv] or according to SEDBUK > 89.1 %
(2009). The stainless steel cylinder burner
therefore consumes relatively little natural gas,
with lower CO2 emissions and less impact on
the environment as a result.
* Viessmann Trained Installers can offer their
customers an extended warranty option up to 7
years.
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 17
Boilers and accessories
16/17
Boilers
Part No.
Description
BPJD030 Vitodens 050-W BPJD 29 kW
BPJD031 Vitodens 050-W BPJD 35 kW
Controls
7537993 Vitotrol 100-W room thermostat (LV)
7537996 Vitotrol 100 UTA programmable room thermostat 24hour (LV)
7537988 Analogue time clock 1 channel
7537989 Digital time clock 2 channel
7552848 Vitotrol 100 UTA wireless plug-in programmable room thermostat, 1 channel 24 hour
7543788 Vitotrol 100 UTDB RF2 wireless plug-in programmable room thermostat, 2 channel 7 day
Inox-Radial heat exchanger
7511618 Vitotrol 100 OpenTherm programmable room controller, 7 day, single channel (load compensation)
7543241 Outside temperature sensor for weather compensated operation
Flues
7411961 Telescopic flue kit Ø 60/100 mm
7441467 Std 1 m horizontal flue kit Ø 60/100 mm (1 000 mm terminal, 87° bend)
7373230 SC vertical flue terminal Ø 60/100 mm
7373227 SC 45° flue elbow Ø 60/100 mm (pair)
7373226 SC 87° flue elbow Ø 60/100 mm
7373225 SC 1.95 m flue extension pipe Ø 60/100 mm
7373224 SC 1 m flue extension pipe Ø 60/100 mm
7373223 SC 0.5 m flue extension pipe Ø 60/100 mm
7176762 SC flue mounting clip Ø 100 mm
7667546 Balanced flue pipe 60/100, 3 m NEW
7667547 Wall terminal 60/100, 1.75 m
7337276 Terminal guard
7373238 Plume management kit
7373266 Flue bend 45° Ø 60 mm (pair)
7373267 Flue bend 87° Ø 60 mm
7373268 Plume kit 1 m flue extension Ø 60 mm
7246572 Fixing clamps - 60 mm
7452499 Roof tile lead Ø 125 black (for 60/100 mm flue system)
7452500 Roof tile lead Ø 125 red (for 60/100 mm flue system)
7452501 Roof tile lead Ø 160 black (for 80/125 mm flue system)
7452502 Roof tile lead Ø 160 red (for 80/125 mm flue system)
7452503 Roof Flashing Kit D=200
050-W showing components
7426187 Flat Roof Collar Alu D=125 H=250 S
ZK00028 Chimney flue kit 60/100 - 12.5 m / room sealed
ZK00029 Chimney flue kit Ø 60/100 mm - 12.5 m / open flued (for longer flue lengths upgrade to Ø 80/125 mm)
7502602 Chimney kit for recess installation 60/100 with flexi 60 mm
7502603 Chimney kit for recess installation 60/100 with flexi 80 mm
7590109 Open flued water protection cap
7373240 Flue adaptor 60/100 to 80/125 mm
For all other accessories please see page 25
10 Year Warranty
on all stainless steel heat exchangers for
gas condensing boilers up to 150 kW
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 18
Installation accessories
4-pipe system
Viessmann Vitodens system boilers up to
Viessmann 4-pipe system
35 kW installed together with a Vitocell 200
or 300 unvented cylinder are the perfect
combination to meet G3 building regulations
Optional weather
compensation sensor
without the need for an energy cut-off valve
and cylinder overheat thermostat; these are
integrated into the boiler.
Installation time will be reduced by up to 1 day
as the following are no longer required:
Energy cut off valve or safety valve
Expansion vessel and pump
Gauge and cylinder overheat thermostat
Part P certification
C
Compatibility
with solar
As a manufacturer of the full range of renewable
energy technologies all Viessmann boilers are
100% compatible with solar thermal panels.
The Vitodens 100/200-W range has the added
advantage of boiler suppression, when using
Viessmann solar panels and a dual coil cylinder.
This means that the hot water system will
always take advantage of solar power, whenever
solar energy is available and the boiler will only
fire to ‘top up‘ the DHW heating process when
absolutely necessary – resulting in significant
fuel savings.
*
Combined PRV and condensate connection
Installation is faster, simpler and more cost-effective
as pressure release valve (PRV) and condensate
connection are combined, and long runs of
additional piping are no longer required.
Combined pressure releasing valve and condensate connection
1
8
2
75
7
5
One less pipe to penetrate the building fabric
All Vitodens domestic boilers (exc Vitodens
100-W Open Vent) feature the combined PRV and
Products
featuring
the combined PRV and
condensate
connection
condensate connection are:
Vitodens 050-W
Vitodens
Vitodens 050-W
100-W
Vitodens
Vitodens 100-W
111-W
Vitodens 111-W
200-W
Vitodens 222-F
Vitodens 242
F
242-F
11
4
Key
1
2
3
4
7
8
9
10
11
≥25
No exterior PRV drip/stain as it feeds into a
single cold water pipe
≥100
Fast and simple installation, saving time and
expense
Built in safety device meaning no discharge
pipe for DHW cylinder
cylinder is
is required
required
3
9
10
Boiler
Visible air break
6
75 mm trap
Visible air break and trap not required if there is a trap with a minimum condensate
seal of 75 mm incorporated into the boiler. In this case the 100 mm is measured to the
trap in the boiler.
Sink, basin, bath or shower
Open end of condensate drainage pipe direct into gully 25 mm min below grating but
above water level; end cut at 45 ˚
Sink lip
Minimum internal diameter 19 mm
Pipe size transition
Minimum internal diameter 30 mm
Water/weather proof insulation
Example of a generic installation with the combined PRV/condensate connection
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 19
Cylinders
18/19
VITOCELL 200-V
The Vitocell 200 range of
unvented hot water storage
cylinders are indirectly
heated cylinders designed
for use with Vitodens
system boilers (or UK
standard boilers).
Model
Height Diameter
kW rating of Heat up time from Stand-by losses Expansion Part no.
(mm)
(mm) primary coil (kW) 15º°C to 60°Cº (min)*
(kWh/24h)**
vessel
200-V 90
732
550
16.5
17
0.89
12litre
7572707
200-V 120
920
550
18
21
1.00
12litre
7572708
200-V 150
1 107
550
18.5
25
1.20
18litre
7572709
200-V 180
1 295
550
19
30
1.30
18litre
7577210
24litre 7572711
200-V 210
1 493
550
25.6
32
1.60
200-V 250
1 733
550
27.1
36
1.80
24litre
7572712
200-V 300
2 020
550
25
38
2.00
40litre
7572713
* Approx re-heat time for 70% of cylinder contents from 15°C to 60°C using a 82°C flow
** Meets CHESS Best practice requirements
VITOCELL 200-B
Dual-mode domestic hot water
cylinders work to heat the
domestic hot water with
separate indirect coils that are
connected directly to the solar
thermal system.
º
38
The Vitocell 300 range of
unvented hot water storage
cylinders are indirectly heated
cylinders designed for use with
Vitodens system boilers and
characterised by the use of
heavy gauge quality stainless
steel.
SS Duplex
PUR
38
2.00
40l
Single coil
Volumes
litres
Material
90/120/150/180/210/250/300
SS 1.4571
SS Duplex
1
Max. pressure
bar
16
10
Operating pressure
bar
Insulation
Heat loss in 24h
Height
10
3
PUR
PUR
kW/hr
1.17
1.4
mm
1 420
1 295
550
Width/diam.
mm
variable
Overallwidth
mm
651
600
Immersion heater
kW
2/6 (400V)
3 (230V)
years
2
25
kW
40
19
kg
85
28
litres
External vessel
External vessel
Expansion vessel type
Twin coil
Volumes
litres
Material
PUR
Vitocell 200-V
200/300/500
2.5 - 2.6
Weight (net)
SS Duplex
Vitocell 300-V
mm
Thickness/gauge
Warranty
The Vitocell 300-B is a dual mode
DHW cylinder with two indirect
coils. Made from high alloy
stainless steel, the Vitocell 300-B
is a reliable and efficient solution
for the integration of two energy
sources. Available in two sizes,
either 300 litres or 500 litres.
40l
º
Coil rating
VITOCELL 300-B
2.00
* Approx re-heat time for 70% of cylinder contents from 15°C to 60°C using a 82°C flow
** Meets CHESS Best practice requirements
º
VITOCELL 300-V
º
Thickness/gauge
Vitocell 300-B 300
Vitocell 200-B 300
300/500
210/250/300
SS 1.4571
SS Duplex
mm
2.8
1
Max. pressure
bar
16
10
Operating pressure
bar
Insulation
10
3
PUR
PUR
Heat loss in 24h
kW
1.17
1.9
Height
mm
1 790
2 020
550
Width/diam.
mm
633
Overall width
mm
700
600
Immersion heater
kW
2/6(400V)
3 (230V)
Warranty
Coil rating
Weight (net)
Expansion vessel type
years
2
25
kW
54
19
kg
100
46
litres
External vessel
External vessel
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 20
Flue location
and ventilation
Flue applications
Vitodens boilers can be installed in virtually all domestic applications,
some examples are illustrated.
1
2
5
6
4
3
4
5
2
3
open flued
Horizontal concentric
4
C ommunal room
5
sealed chimney
Ver tic al outside wall system
Chimney flue (open flued/balance)
6
with flexible duct
3
As a rule of thumb increasing the
diameter of the flue from 60 mm to 80
Maximum flue lengths are provided and
have already allowed for 2 bends of 87°
(including support bends).
For each additional 90° elbow reduce
the maximum flue length by 1 m, each
additional 45° elbow by 0.5 m.
mm will add approximately 15% to the
maximum flue length, but please check
with the Viessmann Technical Department
if in doubt.
Part no.
Boiler flue connection
Balanced flue external wall connection
(incl. wall bezels)
Protective grille
Balanced flue extension pipe
1 m long
0.5 m long
Balanced flue bend
87°
2 x 45°
Fixing clamp
Horizontal flue terminal kit
Flue terminal 1 m, 2 x wall seals,
balanced flue bend
87°
A Combustion air
B Flue gas
Ver tic al, concentric roof
terminal – fl at and pitched
C ommunal flue system –
The maximum flue length is the single
biggest consideration.
3 Horizontal wall terminal
1
2
3
1
60/100
80/125
7441467
7337276
7435862
7189821
7373224
7373223
7194321
7194320
7373226
7373227
7176762
7441467
7194323
7194324
7176664
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 21
Flue location
and ventilation
20/21
5 Routing over an external wall
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Part no.
Boiler flue connection
Balanced flue inspection tee,
87°
o
or
Balanced
flue inspection bend,
8
87°
Balanced flue sliding coupling (optional)
Balanced flue pipe
1.95 m long
1 m long
0.5 m long
Wall bezel
Fixing clamp
Balanced flue inspection piece, straight (optional)
External wall pack
with
Balanced flue bend
87°
Balanced flue air intake
Balanced flue pipe
1.95 m long
1 m long
0.5 m long
(Balanced flue roof outlet
(with a high roof overhang above the roof)
Black
Terracotta
Universal roof tile
Lead Free Flashing Black
Lead Free Flashing Terracotta
External wall terminal (for a short roof overhang)
Balanced flue bend
45°
87°
60/100
60/100
80/125
80/125
7373229
7373236
7199782
7194329
7373225
7373224
7373223
7176760
7176762
7373228
7373234
7194322
7194321
7194320
7176662
7176664
7199781
7194327
7373225
7373224
7373223
7194322
7194321
7194320
7373230
7373231
7373271
7373272
7452499
7452500
7176753
7452501
7452502
7176655
7373227
7373226
7194324
7194323
A Flue gas
B Combustion air
C Step in the external wall routing
for a short roof overhang
1 Vertical terminal for sloping or flat roofs
1
1
2
3
4
5
5
Part no.
P
Boiler
flue connection
B
Balanced flue roof outlet
B
Black
Terracotta
T
Universal roof tile
U
Lead
Free Flashing Black
Lead Free Flashing Terracotta
or Flat roof collar
o
Balanced flue inspection piece,
B
straight (optional)
straight (optional)
Balanced
flue sliding coupling (optional)
B
Balanced
flue bend
87°
2 x 45°
Balanced flue pipe
1 m long
0.5 m long
0
Fixing
clamp
60/100
60/100
80/125
80/125
7373230
7373231
7373271
7373272
7452499
7452500
7248017
7373228
7452501
7452502
7248017
7199781
7373236
7194329
7373226
7373227
7194323
7194324
7373224
7373223
7176762
7194321
7194320
7176664
A Ventilation air
B Flue gas
C (min.) 400 mm
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 22
Flue location
and ventilation
6 Balanced flue operation
1
2
3
4
5
6
7
8
A Combustion air
B Flue gas
C Inspection aperture
D Connection piece
9
Part no.
Boiler flue connection
Standard shaft pack (PPS, flexible) comprising:
Support bend
Support rail
Shaft cover (PPS)
Spacers (5 pce.)
or
Standard shaft pack (metal/PPS, rigid)
For twin flue chimneys (one flue for solid fuel boilers)
comprising:
Support bend
Support rail
Shaft cover (metal)
Terminal pipe (stainless steel)
Spacers (5 pce.)
Spacers (5 pce)
Flexible pipe, on a roll, 12.5 m long.
Flexible pipe, on a roll, 25 m long.
Connecting piece, for connecting residual
lengths of the flexible flue pipe.
Pipe lowering attachment incl. 20 m rope.
Inspection piece, straight for installation in
the flexible flue pipe.
Balanced flue inspection piece, straight.
Wall bezel
Balanced flue pipe
1 m long.
0.5 m long.
Balanced flue bend 87°
Chimney flue kit (12.5 m) comprising:
parts 2, 3, 7, 8, 9
60/100
80/125
7248206
7248213
7452173
7452179
7190560
7248208
7248207
7248211
7147035
7248216
7248215
7248219
7248212
7248210
7248214
7248218
7373228
7176760
7199781
7176662
7373224
7373223
7373226
7194321
7194320
7194323
ZK00028
ZK00030
60/100
80/125
7248206
7248213
7452173
7452179
7190560
7248208
7248207
7248211
7147035
7248216
7248215
7248219
7248212
7248210
7248214
7248218
9373228
7176728
7248312
7176634
7373214
7373215
7194310
7194311
7373218
7373219
7194314
7194315
7373217
7194313
7373278
7373278
ZK00029
ZK00031
2 Open flue operation
1
2
3
4
5
6
7
8
9
A
B
C
D
E
Ventilation air
Flue gas
Inspection port
Connection piece
Ventilation aperture
Part no.
Boiler flue connection
Standard shaft pack (PPS, flexible) comprising:
Support bend
Support rail
Shaft cover (PPS)
Spacers (5 pce.)
or
Standard shaft pack (metal/PPS, rigid)
For twin flue chimneys (one flue for solid fuel boilers)
comprising:
Support bend
Support rail
Shaft cover (metal)
Terminal pipe (stainless steel)
Spacers (5 pce.)
Spacers (5 pce)
Flexible pipe, on a roll, 12.5 m long.
Flexible pipe, on a roll, 25 m long.
Connecting piece, for connecting residual
lengths of the flexible flue pipe.
Pipe lowering attachment incl. 25 m rope.
Inspection piece, straight for installation in
the flexible flue pipe.
Inspection piece, straight
Vent bezel
Pipe
1 m long
0.5 m long
Bend
87°
45° (2 pce)
or
Inspection tee
87°
Stainless steel extension for shaft cover 380 mm long
(metal/PPS, rigid)
Chimney flue kit (12.5 m) comprising:
parts 2, 3, 7, 8, 9
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 23
Flue location
and ventilation
22/23
Flue lengths
2
4
5
6
Max. total flue length up to the boiler flue connection (at system temperature 50/30°C)
Vitodens 050-W Rated output range (kW)
max. length (m) - system size 60/100
Vitodens 100-W Rated output range (kW)
max. length (m) - system size 60/100
Vitodens 100-W Rated output range (kW)
Open Vent
max. length (m) - system size 60/100
Vitodens 111-W Rated output range (kW)
7.9
13.0
8/10
7.9
16.0
8/10
max. length (m) - system size 60/100
Vitodens 200-W Rated output range (kW)
Vitodens 222-F
max. length (m) - system size 60/100
Rated output range (kW)
Vitodens 242-F
max. length (m) - system size 60/100
Rated output range (kW)
3.2
19.0
20
3.2
19.0
20
3.2
19.0
20
max. length (m) - system size 60/100
Allowed for are 2 bends 87° (incl. support bends).
1
3
6.5
19.0
19.0
7.9
19.0
8/10
Max. total flue length up to the boiler flue connection (at system temperature 50/30°C)
Vitodens 050-W Rated output range (kW)
max. length (m) - system size 60/100
Vitodens 100-W Rated output range (kW)
max. length (m) - system size 60/100
Vitodens 100-W Rated output range (kW)
Open Vent
max. length (m) - system size 60/100
Vitodens 111-W Rated output range (kW)
7.9
13.0
8/10
7.9
16.0
8/10
max. length (m) - system size 60/100
Vitodens 200-W Rated output range (kW)
Vitodens 222-F
max. length (m) - system size 60/100
Rated output range (kW)
Vitodens 242-F
max. length (m) - system size 60/100
Rated output range (kW)
6.5
19.0
19.0
7.9
19.0
8/10
3.2
19.0
10
3.2
19.0
10
3.2
19.0
10
max. length (m) - system size 60/100
Allowed for are 2 bends 87° (incl. support bends).
6.5
29.0
10.0
6.5
26.0
13.5
7.9
26.0
8/10
6.5
26.0
15.0
5.2
26.0
20
5.2
26.0
20
5.2
26.0
20
8.8
30.0
13.5
5.2
30.0
15
5.2
30.0
15
6.5
29.0
8/10
6.5
26.0
13.5
7.9
26.0
8/10
6.5
26.0
15.0
5.2
26.0
10
5.2
26.0
10
5.2
26.0
10
8.8
30.0
13.5
5.2
30.0
10
5.2
30.0
10
8.8
35.0
10.0
8.8
35.0
17.0
7.9
35.0
8/10
8.8
35.0
15.0
5.2
35.0
15
5.2
35.0
15
8.8
35.0
8/10
8.8
35.0
17.0
7.9
35.0
8/10
8.8
35.0
15.0
5.2
35.0
10
5.2
35.0
10
Vitodens 100-W Combination & System
For concentric or balanced flue systems the max. flue length can be up to 19 m.
To match the boiler output to the flue system length, a concentric factor has to be set
- see installation instructions.
Communal
Communal Flue
Flue System
System (CFS)
(CFS)
A CFS system could be designed as shown. To be able to provide
correct parts it is important to know how the boiler is linked to the CFS duct.
System size
Parallel adapter ø 60/100mm - ø 60/60 mm
For separate routing of flue gas and ventilation air
Parallel adapter ø 60/100mm - ø 60/60 mm
For separate routing of flue gas and ventilation air
60
80
7418011
7418011
A
B
C
D
Ventilation air
Flue gas
Inspection port
Condensate drain with siphon
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 24
Flue location
and ventilation
Plume management kit
The plume kit enables the relocation of the flue outlet of a standard horizontal flue
system to another position and is available as an optional extra.
Ensure the maximum length of 3 m
The standard plume kit comprises of
(externally) and 7 m (internally) is
not exceeded
the following parts:
87° connection to horizontal terminal
The maximum length is reduced by 1 m
when using a further 87° bend or
2 x 45° bends
Deduct 3 m from the maximum possible
1 m pipe extension
87° flue outlet elbow with bird mesh
Fixing clamps
standard concentric horizontal flue length
and add the standard plume kit maximum
length to give maximum length of entire
flue system. ie. 6 m - 3 m + 2 m = 5 m
maximum
Installed to prevent nuisance
pluming across the window
Typical routing options
A
Item
A Plume kit standard delivery 2 m max. length
B
C
Part
Part
no.no.
7373238
7373238
B Plume kit standard delivery additional options
2 x 87° bends
1 pipe
1 1 m long
7373267
7373267
7373268
7373268
C Plume kit standard delivery additional options
2 x 45° bends
1 pipe
1 1 m long
7373266
7373266
7373268
7373268
Fixing clamps
7246572
7246572
Kit contents
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 25
Accessories
24/25
Vitodens accessories
Description
050-W
100-W
Combination Open Vent
100-W
System &
Combination
111-W
200-W
DHW secondary circuit kit (Vitodens 222-F also requires
7452092 Extension AM1)
Vitocom 100 (Type GSM) for remote control via GSM/mobile
phone network (excl SIM card)
n
n
Vitocom 100 LAN 1 with LON module (not for Vitodens 100 range)
Vitocom 200 LAN 2 with communication module
Condensate pump (Liang) for low level boiler installation
n
n
n
n
n
n
n
Tool kit
Ionisation current test adaptor
n
Plate heat exchanger flushing system
n
n
n
n
n
n
n
n
Solar expansion vessel bracket
222-F
242-F
Part no.
n
n
7514306
n
Z004594
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Z011224
Z011390
7369810
9537070
7822883
7373005
7510546
DHW connection set for third party unvented cylinders includes
extension module H1, DHW sensor
n
Z006704
DHW cylinder sensor with retainer for Vitocell unvented
cylinders (G3 compliant)
n
ZK00539
Wall mounting bracket for Vitotronic 100/200 includes wall
bracket, cover for boiler and 5 m cable
n
7299408
Sub-mounting mixer kit for Vitodens 200-W System up to 35 kW
only with Vitotronic 200 - 2 heating circuits + high efficiency pump
n
ZK02585
Sub-mounting mixer kit for Vitodens 200-W Combi up to 35 kW
only with Vitotronic 200 - 2 heating circuits + high efficiency pump
n
ZK02586
n
Boiler high efficiency modulating pump up-grade (WB2B & WB2C only)
n
Valve fittings cover
n
Solar control module (SM1)
7424493
7438096
7429073
Internal H1 extension
n
7498513
Internal H2 extension (controls extractor fan, DHW secondary pump,
fault messages etc)
n
7498514
n
LPG conversion kit for 19/26 kW
LPG conversion kit for 30/35 kW
n
Tundish set for combined condensate & PRV drain
n
LPG conversion kit for 19/26 kW
LPG conversion kit for 30/35 kW
n
DHW cylinder sensor with retainer for Vitocell unvented cylinders
(G3 compliant)
n
n
Cylinder control box (System boiler)
n
Stand off frame
n
n
7849983
7849984
7459591
7842497
7842498
ZK00539
7296968
7474189
Sub mounting mixer kit
n
Z010820
Pre-plumbing jig Combi boiler for Vitodens 100-W WB1C
- excl filling loop
n
7476447
Pre-plumbing jig System boiler for Vitodens 100-W WB1C
- excl filling loop
n
7476448
LPG conversion kit
LPG conversion kit for 29 kW
LPG conversion kit for 35 kW
Electrical Connection box 230V
Stand off frame
n
n
n
n
n
7828769
7841678
7841679
7582789
7601812
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 26
Control technology
Controls
Viessmann boilers have the added benefit of advanced control technology.
Viessmann controls are easy to install, maintain and
operate and benefit from fault logging and diagnostic
systems. They switch easily between Winter and
Summer settings and some models have useful short
cuts, including holiday, party and economy settings.
All Vitodens boilers will operate with external
controls, Viessmann and non Viessmann.
able to operate at the minimum temperature
required to keep the rooms warm. This keeps the
return temperature as low as possible and a return
temperature of 57°C or less means the boiler can
condense as it is designed to. Weather
compensation maximises the condensing period of
the boiler and results in significant fuel savings.
Lambda Pro Control
The Lambda Pro combustion controller works along
side the burner to constantly monitor the air to gas
ratio. Instead of the gas mix remaining fixed from
installation, the mix is automatically adjusted to
maintain the correct ratio - in a similar way to the fuel
management system in your car engine. This also
means that on-site commissioning time is reduced.
Control unit with colour touchscreen and
energy cockpit
The new Vitotronic 200 control unit in the Vitodens
200 series makes energy consumption
transparent, as it provides the system user with
continuous energy updates. It also informs users
about boiler power and gas consumption.
The Lambda Pro is designed to work efficiently
irrespective of the quality of the gas - a factor which
will become more and more important as
international gas supplies become less reliable.
The control replaces the traditional gas valve and
changing to LPG takes just a few seconds - with no
replacement parts! The Lambda Pro is an integral
component of the Vitodens 200-W, Vitodens
222-F and Vitodens 242-F.
Weather Compensation
Weather compensation controls are a great, low
cost way to make a boiler operate more efficiently.
They can save up to 15% of annual fuel bills – that's
on top of the big savings that you get from
changing to a condensing boiler.
The boiler is connected to a small sensor on the
outside of the building. When the temperature
changes outside, the boiler responds and starts to
increase or decrease the radiator temperature, to
compensate. This pro-active mechanism means
that people inside the building won’t even notice
that the temperature outside has changed. These
constant small changes also mean that the boiler is
Convenient operation at your fingertips
The 5-inch touchscreen clearly displays all
important data in the form of colourful pictograms
and text. The main control functions are
immediately accessible via Favourites. Along with
clear menu structures, this makes operating the
heating system particularly easy and convenient.
Energy cockpit for smart energy
management
Along with the attractive design and the high level
of operating convenience, the new display provides
comprehensive control of the gas consumption for
heating and domestic hot water heating in the form
of an energy cockpit. If a solar thermal system is
connected, solar yields are also captured and
displayed. Colourful histograms also display all data
optionally as daily, weekly, monthly or annual
values. This enables users to comprehensively
control and influence their consumption.
Heating controls for smart phone
Please refer to:
www.viessmann.co.uk/en/viessmann-apps
/vicare-app.html
Scan here for
more information
5 inch colour touchscreen control with energy
cockpit
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 27
Control technology
26/27
Vitotrol 100 control system for Vitodens
Vitotrol 300-A control system for Vitodens
100-W and 100-W Compact
200-W, 222-F and 242-F
Vitotrol 300-A wireless remote control (g)
Thermostat
Vitotrol 100 room thermostat. Basic
room thermostat with switched output
(two-point output) (a)
Vitotrol 100 UTA RF wireless
programmable room thermostat.
Analogue 24 hour, one channel clock (c)
with LCD display for 3 heating circuits for
use with Vitotronic 200
Room temperature sensor (optional)
Up to 2 remote control units can be
connected to the boiler control unit,
Vitotronic 200
Vitotrol 100 UTDB RF2 wireless
Vitotronic control systems for Vitodens
programmable room thermostat.
Digital 7 day, two channel clock with
200-W, 222-F and 242-F, with economic
energy management for all system sizes
Part no. 7141709
large LCD display and selector for
adjusting permanent comfort, permanent
set back and frost protection (d)
Vitotrol 100 open therm. 7 day single
Vitotronic control units think for you –
from installation through to operation and
maintenance. Whether used in an apartment,
channel wired programmable room
controller. For use with the Vitodens 050/
a detached home or in large systems, they
offer the optimum solution for every need. As
100/111-W.
digital control systems with communication
Part no. 7454528
capability they ensure the economical and
Timer
Analogue plug-in clock for operation with
Vitotrol 100 room thermostat. Single
channel plug-in time switch. Heating
program selector switch with switched
output for 24 hour programmable
heating operation (e)
Digital plug-in clock for operation with
Vitotrol 100 room thermostat. Two
channel plug-in time switch for heating and
DHW. 7 day programming, with up to
42 switching programs and
adjustable holiday program (b)
Vitotrol 200 RF control system for
Vitodens 200-W, 222-F and 242-F
Vitotrol 200 RF wireless remote control (f)
with LCD display for 1 heating circuit for use
with Vitotronic 200
reliable operation of your heating system with
well thought out electronic management.
One control system for all boilers
All Viessmann boilers, whether wall mounted
units, small freestanding boilers or larger
boilers – are all controlled by one Vitotronic.
That means: common parts throughout the
Part no. 7454521
entire boiler range, standardised assembly
steps and only a few universal spare parts.
This substantially simplifies installation,
maintenance and service.
The innovative Viessmann modular design
combines the basic chassis and function units
to create various control unit versions – in each
case matching the boiler and the individual
requirements.
Part no. 7537234
Repeater (optional signal booster for
systems with poor reception)
Receiver unit that operates up to 3 Vitotrol
200 RF units
Part no. 7522678 (100/111-W)
Part no. 7522677 (050-W)
Part no. 7511618
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 28
Training
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 29
Training
28/29
The Viessmann Academy
The aim of the Viessmann Academy is to provide knowledge on leading technology to
professionals in the heating industry, thereby taking a vital role in the development of
skill sets and the establishment of new, innovative technologies in the market place.
The Academy has been a major pillar of the
Viessmann philosophy since the 1960s and
each year trains more than 92 000 installers
Here, the Viessmann Academy trains
installers, merchants, engineers, specifiers
and consultants, not only on the current
across the world.
product range but also on many product
types and topics.
Training courses in the United Kingdom
The Viessmann UK Academy is based at the
headquarters in Telford, Shropshire, and also has
external training locations around the country,
currently in Liskeard, Lincoln, Aberdeen,
To request a place on a Viessmann training
course, please contact your Area Business
Manager. To find their contact details,
call 01952 675000.
Bolton, Wishaw, Cambourne Cornwall,
Norwich, Welwyn Garden City,
Salisbury and Swansea.
Scan here
to book online
Scan here
to book online
Viessmann Academy course offer
Domestic
boiler
courses
Domestic
boiler
courses
Gas-fired
Combination
and and
System
boilers
Vitodens
100 and
050
Gas-fired
Combination
System
boilers
Vitodens
100
and 050
range,
including
050-W,
100-W
and
111-W
range, including 050-W, 100-W and 111-W
Gas-fired
Vitodens
200200
range,
including
200-W,
200-W,
Gas-fired
Vitodens
range,
including
222-F
and
242-F,
andand
Vitotronic
controls
222-F
and
242-F,
Vitotronic
controls
Commercial
boiler
courses
Commercial
boiler
courses
Gas-fired
commercial
System
boilerboiler
Vitodens
200-W200-W
Gas-fired
commercial
System
Vitodens
Combined
heatheat
andand
power
(CHP)(CHP)
Combined
power
Control
technology
including
cascade
controls
Control
technology
including
cascade
controls
CPD
courses
request:
CPD
courses
onon
request
(CIBSE Accredited)
District
heating
schemes
District
heating
schemes
Combined
heat
andand
power
(CHP)
Combined
heat
power
(CHP)
System
design
for high
and low
content
boilersboilers
for high
and water
low water
content
System
design
Solar
courses
Solar
courses
Practical
solar
thermal
course
including
the the
Practical
solar
thermal
course
including
Vitodens
242-F
solar
heating
tower
Vitodens 242-F solar heating tower
Biomass
boiler
courses
Biomass
boiler
courses
Introduction
to biomass
boilers
Introduction
to biomass
boilers
Vitoligno range
Heat
pump
courses
Heat
pump
courses
Introduction
to heat
pumps
Introduction
to heat
pumps
Vitocal
200
range
including
ground
source
and air
Vitocal 200 range including
ground
source
andsource
air source
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 30
Contacts
Contact us
Viessmann Ltd, Hortonwood 30, Telford, Shropshire, TF1 7YP
Telephone
Fax
Email
01952 675000
01952 675040
info-uk@viessmann.com
Sales
Telephone – Domestic
Email
Telephone – Commercial
Email
Fax
01952 675010
domsales-uk@viessmann.com
01952 675090
comsales-uk@viessmann.com
01952 678600
Training academy
Telephone
Email
01952 675032
academy-uk@viessmann.com
Scan here
to book online
01952 675070
technical-uk@viessmann.com
Scan here
for technical documents
Technical helpline
Telephone
Email
ErP advice
Email
erp-advice@viessmann.com
Scan here
for ErP calculator
After sales
Telephone
Email
01952 675060
aftersales-uk@viessmann.com
Spares
Telephone
Email
01952 675013
spares-uk@viessmann.com
Online
Register online for engineer service requests and warranties
www.viessmann.co.uk
Scan here
for Spares App
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 31
Further information
30/31
Viessmann – climate of innovation
Viessmann is one of the world's leading
manufacturers of intelligent, convenient and
efficient systems for heating, cooling and
decentralised power generation.
As a third generation family run business,
Viessmann has been supplying highly efficient
and clean heating systems for many decades.
the needs of today are met without
compromising the quality of life of future
generations.
We consider climate protection, environmental
responsibility and resource efficiency to be
key priorities throughout our company, which
has more than 11,600 employees worldwide.
2009/2011/2013:
A strong brand creates trust
Together with our brand label, our key brand
message is an identifying feature throughout
the world. "Climate of innovation" is a promise
on three levels: It is a commitment to a culture
of innovation. It is also a promise of enhanced
product benefits and, at the same time, an
obligation to protect the environment.
Acting in a sustainable manner
For Viessmann, taking responsibility signifies
a commitment to acting sustainably.
This means harmonising ecology, economic
concerns and social responsibility so that
Example of Best Practice
With its strategic sustainability project,
Viessmann demonstrates at its own head
office in Allendorf (Eder) that the energy and
climate policy goals set for 2050 can in fact
be achieved today with commercially available
technology. The results speak for themselves:
for Production/Brand/Resource
Efficiency
„ Expansion of renewables to 60 percent
„ CO2 emissions reduced by 80 percent
The long term goal is for the company to meet
all its own heating energy requirements by
sustainable means.
Viessmann Group
Company details
„ Established in: 1917
„ Employees: 11,600
„ Group turnover: 2.2 billion euros
„ Export share: 56 percent
„ 22 production companies in 11 countries
„ 74 countries with sales companies and
branches
„ 120 sales offices worldwide
German Sustainabilit y Award
The comprehensive product range from
the Viessmann Group for all energy
sources and output ranges
„ Boilers for oil or gas
„ Combined heat and power generation
„ Hybrid appliances
„ Heat pumps
„ Wood combustion technology
„ Biogas production plants
„ Biogas upgrading plants
„ Solar thermal
„ Photovoltaics
„ Accessories
„ Refrigeration systems
Energy Efficiency Award 2010
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 32
Vitodens technical specification
Vitodens 100-W
Appliance
Model
Rated CH Output
At Tf/Tr 50/30 ºC (condensing)
At Tf/Tr 80/60 ºC (non-condensing)
Rated central heating input (net)
Domestic hot water output range
DHW heating efficiency (ErP)
DHW heating energy efficiency
Max. nat gas rate (CH mode)
Max LPG
Gas supply pressure
Natural gas
LPG
Max permissible gas supply pressure
Natural gas
LPG
Efficiency (SEDBUK 2009 / 2012)
Full Load
Part Load
Seasonal efficiency (SEDBUK 2009 / 2012)
ErP Efficiency
Heating seasonal efficiency (ErP)
Energy efficiency class (ErP)
NOx classification
Noise (sound power level)
DHW/CH
DHW performance @ 35˚C temp. rise
DHW temp. range
Maximum mains water inlet pressure
Minimum mains water inlet pressure for max DHW heat output
Minimum mains water inlet pressure for operation
Minimum DHW flow rate for operation
Minimum CH system pressure - cold
Maximum CH system pressure - hot
Cylinder capacity
CH flow temp. range
General specification
Integral expansion vessel capacity
Integral expansion vessel pre-charge pressure
Total water capacity
Lift weight
Total weight (including packaging) Kg
Electricity supply
Internal fuse
Maximum power consumption
Water protect rating
Flue temp. @ 50/30 - max CH output
Flue temp. @ 50/30 - min CH output
Flue temp. @ 80/60 - max CH output
Flue products mass flow rate - NG - max CH output
Flue products mass flow rate - NG - min CH output
Flue products mass flow rate - LPG - max CH output
Flue products mass flow rate - LPG - min CH output
Max. gas pressure NG
Gas Council number
Product ID
Dimensions/Connections
Inner flue duct diameter
Outer flue duct diameter
Boiler dimensions (height x width x depth)
DHW outlet & mains cold inlet
CH flow & return
Condensate
Gas
PRV outlet
Max horizontal flue length
Max vertical flue length
System B1HC
26
26
Combi B1KC
30
35
8.2 - 36.5
n/a
n/a
n/a
3.5
2.6
4.7 – 26
4.7 - 23.8
6.1 - 17.8
5.9 - 26
82
A
2.6
1.9
5.8 – 30
5.3- 27.3
8.2 - 31.3
8.0 - 30
81
A
3
2.2
5.8 – 35
5.3 - 32
8.2 - 36.5
8.0 - 35
81
A
3.5
2.6
20
37
20
37
20
37
20
37
20
37
25
45
25
45
25
45
25
45
25
45
25
45
97.92
108.7
89.2
97.95
108.6
89.2
98.02
108.2
89
97.91
109.3
89.4
97.95
108.6
89.1
98.02
108.2
88.9
97.91
109.3
89.3
94
A
94
A
94
A
48 dB
Unit
19
KW
KW
KW
KW
%
4.7 – 19
4.3 - 17.4
6.1 - 17.8
n/a
n/a
n/a
1.9
1.4
4.7 – 26
4.3 - 23.8
6.1 - 27.1
n/a
n/a
n/a
2.6
1.9
5.8 – 30
5.3 - 27.3
8.2 - 31.3
n/a
n/a
n/a
3
2.2
20
37
20
37
25
45
100%
30%
%
m3/h
kg/H
˚C
ltr
bar
ltr
kg
kg
A
W
ºC
ºC
ºC
kg/h
kg/h
kg/h
kg/h
mbar
mm
mm
mm
mm
mm
mm
mm
m
m
35
5.8 – 35
5.3 - 32
94
A
94
A
94
A
49 dB
94
A
5 (<39 mg/kWh)
49 dB
48 dB
49 dB
49 dB
48 dB
n/a
n/a
n/a
n/a
n/a
n/a
0.5
3
n/a
30-80
n/a
n/a
n/a
n/a
n/a
n/a
0.5
3
n/a
30-80
n/a
n/a
n/a
n/a
n/a
n/a
0.5
3
n/a
30-80
10
30-60
10
0.5
0.5
0.5
0.5
3
n/a
30-80
12
30-60
10
0.5
0.5
0.5
0.5
3
n/a
30-80
14
30-60
10
0.5
0.5
0.5
0.5
3
n/a
30-80
8
0.75
2.8
35
37
230v 50 HZ
2.5
84
IP X4D
45
35
68
30.1
14.6
34
15.9
20 - 25
41-819-36
8
0.75
2.8
36
38
230v 50 HZ
2.5
92
IP X4D
45
35
68
41.1
14.6
46.4
15.9
20 - 25
41-819-37
8
0.75
3.4
37
39
230v 50 HZ
2.5
98
IP X4D
45
35
68
49.0
17.6
54.0
19.4
20 - 25
41-819-38
8
0.75
3.4
37
39
230v 50 HZ
2.5
108
IP X4D
45
35
69
56.9
17.6
62
19.4
20 - 25
41-819-39
CE-0085 BT0029
8
0.75
2.8
36
38
230v 50 HZ
2.5
97
IP X4D
45
35
68
41.1
14.6
46.4
15.9
20 - 25
47-819-33
8
0.75
3.4
38
40
230v 50 HZ
2.5
105
IP X4D
45
35
68
49.0
17.6
54.0
19.4
20 - 25
47-819-34
8
0.75
3.4
38
40
230v 50 HZ
2.5
119
IP X4D
45
35
70
56.9
17.6
62.0
19.4
20 - 25
47-819-35
60
100
60
100
60
100
60
100
60
100
60
100
n/a
22
22
22
n/a
19
19
n/a
22
22
22
n/a
13.5
13.5
n/a
22
22
22
n/a
13.5
13.5
60
100
700 x 400 x 350
n/a
22
22
22
n/a
17
17
15
22
22
22
n/a
13.5
13.5
15
22
22
22
n/a
13.5
13.5
15
22
22
22
n/a
17
17
class
l/min
˚C
bar
bar
bar
l/min
bar
bar
30
n/a
n/a
n/a
n/a
n/a
n/a
0.5
3
n/a
30-80
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 33
Vitodens technical specification
13
32/33
Vitodens 100-W Compact WB1B
Open Vent
16
19
26
35
Vitodens 050-W BPJD
Combi
29
35
7.9-13
7.2-11.9
7.4-12.2
n/a
n/a
n/a
1.3
0.9
7.9-16
7.2-14.6
7.4-15.0
n/a
n/a
n/a
1.6
1.1
7.9-19
7.2-17.3
7.4-17.8
n/a
n/a
n/a
1.9
1.4
7.9-26
7.2-23.7
7.4-24.3
n/a
n/a
n/a
2.6
1.9
11.0-35
10.0-31.9
10.3-32.7
n/a
n/a
n/a
3.5
2.6
6.5-24
5.9-21.9
6.1-22.4
5.9-29
80
A
2.37
1.71
8.8-33
8.0-30.1
8.2-30.9
8.0-35
78
A
3.28
2.36
20
37
20
37
20
37
20
37
20
37
20
37
20
37
25
45
25
45
25
45
25
45
24
45
25
45
25
45
97.7
108.4
89
97.8
108.4
89.1
97.7
108.4
89
97.7
108.4
89.3
98.0
109.0
88.7
97.4
108.8
89
97.5
108.7
89
94
A
94
A
94
A
94
A
94
A
48 dB
48 dB
5 (<39 mg/kWh)
49 dB
49 dB
50 dB
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
30-75
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
30-75
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
30-75
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
30-75
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
30-75
n/a
n/a
3.1
25
30
230v, 50 HZ
2.5
55
IP X4D
45
35
68
n/a
n/a
n/a
n/a
20-25
41-819-23
n/a
n/a
3.1
25
30
230v, 50 HZ
2.5
60
IP X4D
45
35
69
n/a
n/a
n/a
n/a
20-25
41-819-24
n/a
n/a
3.1
25
30
230v, 50 HZ
2.5
65
IP X4D
45
35
69
n/a
n/a
n/a
n/a
20-25
41-819-25
60
100
60
100
60
100
n/a
n/a
22
22
15
8
10
n/a
n/a
22
22
15
8
10
n/a
n/a
3.1
25
30
230v 50 HZ
2.5
45
IP X4D
45
35
68
n/a
n/a
n/a
n/a
20-25
41-819-21
60
100
n/a
n/a
22
22
15
8
10
n/a
n/a
3.1
25
30
230v, 50 HZ
2.5
50
IP X4D
45
35
68
n/a
n/a
n/a
n/a
20-25
41-819-22
CE- 0085 BT 0029
60
100
600x375x285
n/a
n/a
22
22
15
8
10
600 x 375 x 340
n/a
n/a
22
22
15
8
10
93
A
5 (<39 mg/kWh)
45 dB
12
30-60
10
1
0.1
2.1
0.8
3
n/a
30-80
8
0.75
2.2
37
39
230v, 50 HZ
2.5
118
IPX4D
45
35
68
n/a
n/a
n/a
n/a
25
47-819-31
CE-0085CP0029
60
100
707 x 400 x 350
15
15
22
22
n/a
15
15
93
A
48 dB
14
30-60
10
1
0.1
2.1
0.8
3
n/a
30-80
8
0.75
2.9
39
41
230v, 50 HZ
2.5
142
IPX4D
45
35
68
n/a
n/a
n/a
n/a
25
47-819-32
60
100
15
15
22
22
n/a
20
20
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 34
Vitodens technical specification
Vitodens 200-W
Model
Rated CH Output
At Tf/Tr 50/30 °C (condensing)
At Tf/Tr 80/60 °C (non-condensing)
Rated central heating input (net)
Domestic hot water output range
DHW heating efficiency (ErP)
DHW heating energy efficiency
Max. nat gas rate (CH mode)
Max LPG
Gas supply pressure
Natural gas
LPG
Max permissible gas supply pressure
Natural gas
LPG
Efficiency (SEDBUK 2009 / 2012)
Full Load
Part Load
Seasonal efficiency (SEDBUK 2009 / 2012)
ErP Efficiency
Heating seasonal efficiency (ErP)
Energy efficiency class (ErP
NOx classification
Noise (sound power level)
DHW/CH
DHW performance @ 35°C temp. rise
DHW temp. range
Maximum mains water inlet pressure
Minimum mains water inlet pressure for max DHW heat output
Minimum mains water inlet pressure for operation
Minimum DHW flow rate for operation
Minimum CH system pressure - cold
Maximum CH system pressure - hot
Cylinder capacity
CH flow temp. range
General specification
Integral expansion vessel capacity
Integral expansion vessel pre-charge pressure
Total water capacity
Lift weight
Total weight (including packaging) Kg
Electricity supply
Internal fuse
Maximum power consumption
Water protect rating
Flue temp. @ 50/30 - max CH output
Flue temp. @ 50/30 - min CH output
Flue temp. @ 80/60 - max CH output
Flue products mass flow rate - NG - max CH output
Flue products mass flow rate - NG - min CH output
Flue products mass flow rate - LPG - max CH output
Flue products mass flow rate - LPG - min CH output
Max. gas pressure NG
Gas council number
Product ID
Dimensions/Connections
Inner flue duct diameter
Outer flue duct diameter
Boiler dimensions (height x width x depth)
DHW outlet & mains cold inlet
CH flow & return
Condensate
Gas
PRV outlet
Max horizontal flue length
Max vertical flue length
30
35
26
Combi B2KB
30
35
2.6-26
2.4-24.1
2.5-24.7
n/a
n/a
n/a
2.61
1.93
2.6-30
2.4-28
4.9-28.5
n/a
n/a
n/a
3.01
2.22
1.8-35
1.6-31.7
4.9-33.0
n/a
n/a
n/a
3.49
2.57
2.6-26
2.4-24.1
4.9-24.7
4.7-29.7
80
A
3.23
2.38
2.6-30
2.4-28
4.9-28.5
4.7-30.5
81
A
3.31
2.45
1.8-35
1.6-32.5
4.9-33.0
4.7-34.0
81
A
3.69
2.73
20
37
20
37
20
37
20
37
20
37
20
37
20
37
25
45
25
45
25
45
25
45
25
45
25
45
25
45
100%
30%
97.53
108.5
89
97.95
108.5
89.1
97.91
108.6
89.1
97.72
108.8
89.2
97.95
108.5
89
97.91
108.6
89
97.72
108.8
89.1
%
92
A
92
A
92
A
92
A
92
A
92
A
32 dB
36 dB
36 dB
36 dB
36 dB
36 dB
n/a
n/a
n/a
n/a
n/a
n/a
0.5
3
n/a
30-75
n/a
n/a
n/a
n/a
n/a
n/a
0.5
3
n/a
30-75
n/a
n/a
n/a
n/a
n/a
n/a
0.5
3
n/a
30-75
10.3
30-60
10
1
0.3
3
0.5
3
n/a
30-75
12.3
30-60
10
1
0.3
3
0.5
3
n/a
30-75
14.3
30-60
10
1
0.3
3
0.5
3
n/a
30-75
10
0.75
7.2
40
48
230v 50 Hz
6.3
80
IPX4D
45
35
68
33.3
8.4
32.5
8.2
20-25
41-819-32
10
0.75
7.8
41.6
50
230v 50 Hz
6.3
86
IPX4D
45
35
70
47.3
11.8
46.4
11.5
20-25
41-819-33
10
0.75
8.2
41.6
52
230v 50 Hz
6.3
95
IPX4D
45
35
70
54.2
15.7
58.5
15.4
20-25
41-819-34
10
0.75
8.2
47
52
230v 50 Hz
6.3
110
IPX4D
45
35
70
63.2
15.7
68.2
15.4
20-25
41-819-35
CE-0085CN0050
10
0.75
7.8
46
51
230v 50 Hz
6.3
108
IPX4D
45
35
70
47.3
11.8
46.4
11.5
20-25
47-819-28
10
0.75
8.2
48
53
230v 50 Hz
6.3
119
IPX4D
45
35
70
54.2
15.7
58.5
15.4
20-25
47-819-29
10
0.75
8.2
48
53
230v 50 Hz
6.3
123
IPX4D
45
35
70
63.2
15.7
68.2
15.4
20-25
47-819-30
60
100
60
100
60
100
60
100
60
100
60
100
n/a
22
22
20-24
15
10
10
n/a
22
22
20-24
15
10
10
n/a
22
22
20-24
15
10
10
60
100
850 x 450 x 375
n/a
22
22
20-24
15
10
10
15
22
22
20-24
15
10
10
15
22
22
20-24
15
10
10
15
22
22
20-24
15
10
10
Unit
19
KW
KW
KW
KW
%
1.9-19
1.7-17.6
1.8-17.9
n/a
n/a
n/a
1.89
1.4
m3/h
kg/H
System B2HB
26
class
l/min
°C
bar
bar
bar
l/min
bar
bar
°C
ltr
bar
ltr
kg
kg
A
W
IPX4D
°C
°C
°C
kg/h
kg/h
kg/h
kg/h
mbar
mm
mm
mm
mm
mm
mm
mm
m
m
92
A
5 (<39 mg/kWh)
36 dB
n/a
n/a
n/a
n/a
n/a
n/a
0.5
3
n/a
30-75
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 35
Vitodens technical specification
Vitodens 111W B1LD
Storage Combi
26
34/35
Vitodens 222-F B2TB
Storage Combi
26
35
19
4.7-26
4.3-23.8
6.1-30.5
4.3-29.6
80
A
3.23
2.39
5.8-35
5.3-32
8.2-36.5
5.3-34
77
B
3.86
2.86
1.9-19
1.7-17.6
1.8-17.9
1.7-17.2
80
A
1.89
1.4
2.6-26
2.4-24.1
2.5-30.5
2.4-29.3
78
B
3.23
2.38
1.8-35
1.6-32.5
1.7-34.9
1.6-33.5
77
B
3.69
2.73
1.9-19
1.7-17.6
1.8-17.9
1.7-17.2
80
A
1.89
1.4
2.6-26
2.4-24.1
2.4-30.5
2.4-29.3
80
A
3.23
2.39
20
37
20
37
20
37
20
37
20
37
20
37
20
37
25
45
25
45
25
45
25
45
25
45
25
45
25
45
97.95
108.6
89.5
97.91
109.3
89.7
97.53
108.5
89.3
97.95
108.5
89.4
97.72
108.8
89.5
97.53
108.5
89.3
97.95
108.5
89.4
94
A
94
A
92
A
92
A
92
A
92
A
92
A
49 dB
49 dB
41 dB
5 (<39 mg/kWh)
45 dB
48 dB
40 dB
43 dB
18
30-60
10
1
0.1
0.5
0.5
3
46
30-80
18
30-60
10
1
0.1
0.5
0.5
3
46
30-80
18
30-60
10
>0.1
0.1
0.1
0.5
3
100
30-75
20
30-60
10
>0.1
0.1
0.1
0.5
3
100
30-75
20
30-60
10
>0.1
0.1
0.1
0.5
3
130
30-75
16.4
30-60
10
0.1
0.1
0.1
0.5
3
170
30-75
19.0
30-60
10
0.1
0.1
0.1
0.5
3
170
30-75
8
0.75
2.8
64
69
230v, 50 Hz
2.5
153
IPX4D
45
35
68
63.2
15.7
68.2
15.4
25
47-819-25
12
0.75
2.8
105
109
230v, 50 Hz
6.3
126
EN 60529
45
35
68
31.8
5.5
30.2
7.6
20-25
47-819-15
12
0.75
3.4
148
152
230v, 50 Hz
6.3
148
EN 60529
45
35
68
54.3
8.7
51.5
14
20-25
47-819-16
CE-0085 BU 0051
12
0.75
3.4
163
167
230v, 50 Hz
6.3
163
EN 60529
45
35
70
62.1
8.7
58.9
14
20-25
47-819-17
60
100
60
100
60
100
60
100
15
22
22
22
n/a
17
17
15
22
22
20-24
n/a
10
10
15
22
22
20-24
n/a
10
10
15
22
22
20-24
n/a
10
10
8
0.75
2.8
62
67
230v, 50 Hz
2.5
141
IPX4D
45
35
65
47.3
11.8
46.4
11.5
25
47-819-24
CE-0085BT0029
60
100
900x600x480
15
22
22
22
n/a
13.5
13.5
35
Vitodens 242-F B2UB
Solar DHW Storage
19
1425x600x595
12
0.75
170
161
166
230v, 50 Hz
6.3
160
IPX4D
45
35
68
31.8
5.5
30.2
7.6
20-25
47-819-18
CE-0085 BU 0051
60
100
1875x600x595
15
22
22
20-24
n/a
10
10
26
12
0.75
170
165
170
230v, 50 Hz
6.3
209
45
35
68
43.9
8.7
41.7
14
20-25
47-819-19
60
100
15
22
22
20-24
n/a
10
10
101527 BOILER GUIDE 36-PAGE REVISED NOV 2016.qxp_Layout 1 31/10/2016 10:34 Page 36
climate of innovation
Viessmann Limited
Hortonwood 30, Telford
Shropshire, TF1 7YP
Tel: 01952 675000
Fax: 01952 675040
www.viessmann.co.uk
Your trade partner:
9443 449 GB 11/2016
Copyright Viessmann
Duplication and alternative use only with prior written consent.
Subject to technical modifications.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project