ZETA Infinity ID2 tri-fold brochure
Infinity ID2 - Product Range
25 Years of Manufacturing Excellence
Other Zeta Products
25 Years of Manufacturing Excellence
25 Years of Manufacturing Excellence
25 Years of Manufacturing Excellence
Panels
ID2/2
37-660
Infinity ID2 - 2 Zone Fire Panel
ID2/4
37-661
Infinity ID2 - 4 Zone Fire Panel
ID2/8
37-663
Infinity ID2 - 8 Zone Fire Panel
ID2/2/D
37-665
Infinity ID2 - 2 Zone Fire Panel with Deeper Back Box
ID2/4/D
37-666
Infinity ID2 - 4 Zone Fire Panel with Deeper Back Box
ID2/8/D
37-668
Infinity ID2 - 8 Zone Fire Panel with Deeper Back Box
ID2/REP
37-669
Fully Functional LCD Repeater
Simplicity Plus
Addressable Fire
Alarm System
Premier Quatro
Premier M Plus & Infinity 8
007
Assessed to ISO 9001: 2008
Certificate number 330
Conventional Fire
Alarm Systems
007
Assessed to ISO 9001: 2008
Certificate number 330
Addressable Fire
Alarm System
007
Assessed to ISO 9001: 2008
Certificate number 330
Detectors & Call Points
Fyreye MKII Detectors
MKII-OP
80-200
Fyreye MKII Fyreye Optical Smoke Detector
MKII-HR
80-202
Fyreye MKII Fyreye ROR Heat Detector
MKII-HF
80-204
Fyreye MKII Fyreye Fixed Heat Detector
MKII-OH
80-206
Fyreye MKII Fyreye Opto-Heat Detector
42-654
Infinity ID2 Combined Sounder & Flasher Base
ID2-MCP
43-640
Infinity ID2 Addressable Manual Call Point
ID2-MCP/WP
42-641
Infinity ID2 Addressable Weatherproof Manual Call Point
25 Years of Manufacturing Excellence
Detector Bases
ID2-SFB
Manual Call Points
Gas Sense
Gas Detection System
Premier EVACS 16
Voice Alarm System
eclipse
Security Alarm
Systems
Sounders & Flashers
Xtratone Range
MKII-AXT/R
42-610
Zeta Addressable Xtratone Sounder, Red, Fyreye II Protocol
MKII-AXT/W
42-611
Zeta Addressable Xtratone Sounder, White, Fyreye II Protocol
MKII-AXTSF/R
42-612
Zeta Addressable Xtratone Sounder Flasher, Red, Fyreye II Protocol
MKII-AXTF/R
42-613
Zeta Addressable Xtratone Flasher, Red, Fyreye II Protocol
GSM-COM
48-900
GSM Communicator - 2 input, 2 output
IP-COM
48-905
TCP/IP Communicator in Enclosure
48-109
Zeta Addressable Input/Output Module (MKII)
MKII-ARL/W
48-034
MKII Addressable Remote LED Indicator (Wall Mounted)
MKII-ARL/C
48-033
MKII Addressable Remote LED Indicator (Ceiling Mounted)
Available now from:
Communicators
INFINITY
Interfaces
ZAIO-M
LED Remote Indicator
007
Assessed to ISO 9001: 2008
Certificate number 330
Tel: +44 (0) 1792 455 175
Fax: +44 (0) 1792 455 176
Email:info@zetaalarmsystems.com
Web: www.zetaalarmsystems.com
5
Detection House
72-78 Morfa Road
Swansea
SA1 2EN
United Kingdom
The Intelligent 2 Wire Fire
Detection System for Professionals
Infinity ID2
Infinity ID2
Infinity ID2
The intelligent 2 wire fire detection system for professionals
The intelligent 2 wire fire detection system for professionals
The intellegent 2 wire fire detection system for professionals
In a nutshell
Special Detector Bases
Zeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We
can now provide a system that gives all of the benefits associated with a ‘2 Wire’ installation
(less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the
devices.
Our bases all come with both
sounder and LED flasher as
standard. This makes our system the
only system available today with
a sounder and flasher with every
detector, improving the audibility
and visual identification of an
alarm.
The system is built on the proven communication protocol developed by Zeta Alarm Systems and
shares the same platform as our largest, most powerful system.
The Infinity ID2 can be used for new installations, as a retro-fit for any conventional system
or as a replacement for existing 2 wire systems when the extra features are deemed to be
desirable/necessary. This is possible because the Infinity ID2 devices sit on radial circuits, thus
making it easy to ‘upgrade’ a system with the facility to I.D. devices without the need to rewire.
Standards
The Infinity ID2 fire alarm system
has been designed to meet the full
requirements of BSEN5839 part 1
and BSEN5839 part 6.The control
panel has been designed to meet
EN54 part 2 and EN54 part 4.
Alarm Verification
Each smoke detector can be simply
programmed to verify an alarm
before a full evacuation. This gives
the benefit of being able to operate
an individual detector’s sounder/
flasher base and have a time period
to clear the smoke/verify the
alarm. This makes the Infinity ID2
perfect for HMO installations.
Cable Short Circuit
Protection
Each zone is equipped with a short
circuit isolator built-in to the panel,
so any short circuit, no matter
how severe, will not affect the
electronics in the control panel.
System Monitoring
Cabling
Alarm Indication
A single pair of wires is used from
each zone terminal (radial circuit)
which connects all detectors, call
points, warning devices (sounders/
flashers) and interfaces. There is
no requirement for an ‘End of line’
device. This will save a significant
amount on the cost of traditional
conventional or addressable systems
(around 40% or more in the majority
of cases).
Each device can be uniquely
identified (I.D.) by the panel and a
20 character label set for each. In
the event of a fire or fault the exact
device that triggered the event will
be shown.
Since every device is monitored
constantly and communicates with
the panel at a maximum interval
of 4 seconds, any malfunction in
any device will be reported by the
panel. This of course will include
the exact location of the device.
Installation &
Commissioning
Alarm, Fault & System
History
In addition to the benefits already
listed, once the panel has been
connected a ‘Device Count
Verification’ feature will confirm the
number and type of every device.
This can then be checked against
the system specification.
The Infinity ID2 includes a 2048
event history that stores all alarm,
fault and system events.
Cable Break Protection
In the event of a cable break, the
panel will report the break. The
devices after the break will be lost,
but will be listed one-by-one on
the panel display to help locate the
break.
No end of lines
required
Zone Check - Cable
Integrity & Zone
Identification Facility
Input/Output
Module
Our Zone Check facility allows you
to illuminate the LEDs and flash the
LED flashers of all devices contained
within a zone. This has many
benefits including identifying the
location of a zone if you are visiting
an installation for the first time and
also checking the cable runs to all
devices that should be contained in
a zone. (It is also possible to narrow
this down to an individual device if
required).
No need for separate
sounder circuits
All detectors have a
sounder flasher as
standard
All devices sit on 2
core zone cable
Additional Features
One man walk test facility
Ability to isolate zones/sounder
circuits
High visibility blue LCD screen as
standard
Deeper version panel available if
larger batteries required
Full range of zone powered devices
available
Internet
Auto configuration for easy set up
Safer than a traditional 2 wire/
conventional system as it tells you
exactly where the event is - no time
wasted searching a whole zone
System already wired as a loop? No
problem! Just select ‘Loop Mode’ in
the panel
GSM Communicator
sends alerts to your
mobile phone
TCP-IP
Communicator
Fully Functional
Repeater Panel
2
3
4
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising