Multi F Inverted Heat Pump Outdoor Unit (369 Model)

Multi F Inverted Heat Pump Outdoor Unit (369 Model)
Job Name/Location:
Tag #:
Date:
For:
PO No.:
Architect:
GC:
Engr:
Mech:
File
Resubmit
Approval
Other
Rep:
(Company)
(Project Manager)
LMU369HV
Multi F Inverter Heat Pump Outdoor Unit
Operating Range:
Performance:
Nominal Cooling Capacity (Btu/h)
36,000
Cooling Power Input (kW)
2.72
3.58
Heating Power Input (kW)
Cooling Nominal Test Conditions:
Indoor: 80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB
Heating Nominal Test Conditions:
Indoor: 70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
Electrical:
Power Supply (V¹/Hz/Ø)
Cooling (°F DB)
Heating (°F WB)
0‐64
Unit Data:
Refrigerant Type
R410A
Refrigerant Control
Sound Pressure³ (Cool/Heat) ±3 dB(A)
EEV
57/57
208‐230/60/1
Net Unit Weight (lbs)
199
25
16.8
Shipping Weight (lbs)
Heat Exchanger Coating
Min Number of Indoor Units
217
GoldFin™
2
Max Number of Indoor Units
4
MOP (A)
MCA (A)
Cooling Rated Amps (A)
18.6
Heating Rated Amps (A)
19.0
12.1
Compressor (A)
Fan Motor (A)
1.1
Compressor:
MOP ‐ Maximum Overcurrent Protection MCA ‐ Minimum Circuit Ampacity
Quantity
Piping:
Type
Refrigerant Charge (lbs)
Liquid Line (in, OD)
7.72
1/4 (4 Each)
Vapor Line (in, OD)
3/8 (4 Each)
Max Total Piping (ft)²
246.1
Max ODU to IDU Piping (ft)
82.0
Piping Length (no add'l refrigerant, ft)
Max Elevation between ODU and IDU (ft)
98.4
49.2
Max Elevation between IDU and IDU (ft)
24.6
ODU ‐ Outdoor Unit
14‐118
IDU ‐ Indoor Unit
Controls Features:
•Auto opera on •Low ambient opera on to •Auto restart opera on 14F (cooling mode)
•Defrost/Deicing
•Restart delay (3‐minutes)
•Inverter (variable •Self diagnosis
•So start
speed compressor)
Optional Accessories:
1
Twin‐Rotary Inverter
Oil/Type
FVC68D
Fan:
Type
Propeller
Quantity
Fan Motor/Drive
2
Brushless Digitally Controlled/Direct
Airflow Rate (CFM)
2,119
Notes:
1.Acceptable opera ng voltage: 187V‐253V.
2.Piping lengths are equivalent.
3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
4.All power/communica on cable to be minimum 18 AWG, 4‐conductor, stranded, shielded and must comply with applicable local and national code.
5.Power wiring cable size must comply with the applicable local and na onal code.
6.See Engineering Manual for sensible and latent capaci es.
7.Power wiring cable size must comply with the applicable local and na onal code.
8.This data is rated 0 above sea level, with 24.6 of refrigerant line and a 0 level difference between outdoor and indoor units. All capacities are net with a combination ratio between 95 – 105%.
9.Refer to the Engineering Product Data Book for combina on capacity tables.
10.The outdoor unit combined with non‐ducted indoor units qualifies for Energy Star.
11.Must follow installa on instruc ons in the applicable LG installa on manual.
PI‐485 Integration Board ‐ PMNFP14A0
AC Smart Premium ‐ PQCSW421E0A
AC Ez ‐ PQCSZ250S0
Power Distribution Indicator ‐ PQNUD1S00
For a complete list of available accessories, contact your LG representative.
For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com
DFS‐SB‐AD‐004‐US 014D23
Page 1 of 2
Job Name/Location:
LMU369HV
Tag #:
Multi F Inverter Heat Pump Outdoor Unit
Date:
PO No.:
For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com
DFS‐SB‐AD‐004‐US 014D23
Page 2 of 2