TECHNICAL RANGE
Pressure
Control Valves
Fast, Secure, Inexpensive
Pressure Cotrol Valves (PCV)
The pressure control valves effectively reduce high mains pressure, resulting in less water delivery at
taps. The expansion relief pressure control functions are all situated on one spindle, so there is no chance
of conflicting settings causing the valve to unnecessarily relieve pressure and thereby waste water.
100
90
80
70
L/Min
60
50
40
30
20
10
0
10
20
30
40
50
100
150
200
250
300
350
400
Flow Pressure
MF1 20mm 400KPA PA3.132
MF3 22mm 400KPA PA6.342
MF2 15mm 400KPA PA4.331
MF3 15mm 400KPA PA6.341
Closy 20mm 400KPA PA1.1
Flow
Pressure
MF1 20mm
400KPA PA3.132
MF3 22mm
400KPA PA6.342
MF3 15mm
400KPA PA6.341
MF2 15mm
PA4.331 400KPA
Closy 20mm
PA1.1 400KPA
10
20
30
40
50
100
150
200
250
300
350
400
16
20
24
26
28
38
48
54
60
64
70
74
22
28
32.5
36
38
50
60
68
76
82
88
92.5
18
22
24
26
28
38
44
50
56
60
66
70
14
18
20
24
26
36
42
48
52
57
62
66
16
22
26
29
32
44
56
64
74
80
86
92
KWIKFLO
Description: 400kPa system pressure with integral expansion
relief valve. Stainless steel seat & strainer.
PA1.1
Code:
CLOSY
Description: 100kPa system pressure with integral expansion
relief valve and vacuum breaker. Stainless steel
seat & strainer.
PA1.1L
Code:
CLOSY
Description: 200kPa system pressure with integral expansion
relief valve and vacuum breaker. Stainless steel
seat & strainer.
PA1.1L+
Code:
MASTERFLO 1
Description: 400kPa system pressure with integral expansion
relief valve. Stainless steel seat and strainer
(double mesh). ¾” BSP male iron inlet and outlet
cap and lining couplings.
PA3.132
Code:
GEYSER VALVE PACK
Description: Consisting of 1 x PA3.132, 2 x PB6.302 and
1 x ¾” BSP female iron valvecock.
PA3.132PK
Code:
SANS198
MASTERFLO 1
Description: 400kPa system pressure with integral expansion
relief valve. 22mm Copper to Copper. Stainless
steel seat & strainer (double mesh).
PA3.332
Code:
GEYSER VALVE PACK
Description: Consisting of 1 x PA3.332, 2 x PB6.303 and
1 x 22mm Copper to Copper inlet & outlet 22mm
valvecock.
PA3.332PK
Code:
MASTER BOX
Description: With 1 x PA3.132, ballcock, funnel, box with lid,
strainer, 2 x PB6.303 vacuum breakers. ¾” BSP
inlet & outlet.
PA5.1
Code:
MASTER METER BOX
Description: With 1 x PA3.132, ballcock, funnel, box with lid,
3
2 x PB6.303 vacuum breakers. Kent M /H Water
Meter.
PA5.1M
Code:
MASTERFLO II
Description: 100kPa system pressure with integral expansion
relief valve. 15mm Copper to Copper. Stainless
steel strainer.
SANS198
MASTERFLO II
Description: 200kPa system pressure with integral expansion
relief valve. 15mm Copper to Copper. Stainless
steel strainer.
PA4.321
Code:
MASTERFLO II
Description: 400kPa system pressure with integral expansion
relief valve. 15mm Copper to Copper. Stainless
steel strainer.
PA4.331
Code:
GEYSER VALVE PACK
Description: Consisting of 1 x PA4.331, 2 x PB6.301 and
1 x 15mm Copper to Copper valvecock.
PA4.331PK
Code:
MASTERFLO II
Description: 400kPa system pressure with integral expansion
relief valve. Stainless steel seat & strainer (double
mesh). 22mm Copper to Copper.
PA4.332
Code:
GEYSER VALVE PACK
Description: Consisting of 1 x PA4.332, 2 x PB6.303 and
1 x 22mm Copper to Copper valvecock. Acetyl valve
seat.
PA4.332PK
Code:
SANS198
MASTERFLO II
Description: 100kPa system pressure with integral expansion
relief valve. 22mm Copper to Copper + 2 X PB6.303.
Stainless steel strainer. Acetyl valve seat.
PA4.712
Code:
GEYSER VALVE PACK
Description: Consisting of 1 x PA4.712, 2 x PB6.303 and
1 x 22mm Copper to Copper valvecock. Acetyl valve
seat.
PA4.712PK
Code:
MASTERFLO II
Description: 200kPa system pressure with integral expansion
relief valve. 2 X PB6.303. 22mm Copper to Copper.
Stainless steel strainer.
PA4.722
Code:
MASTERFLO II
Description: 300kPa system pressure with integral expansion
relief valve. Stainless steel strainer, acetyl valve
seat. 2 X PB6.303. 22mm Copper to Copper.
PA4.732
Code:
SANS198
MASTERFLO III
Available in 400kPa and 600kPa pressure ratings.
Connection size: 15mm and 22mm for copper tube systems to facilitate ease and low
cost installation.
Excellent flow rates.
Complete with expansion relief valve.
Operating cartridge and expansion relief valve can easily be removed from the body.
Hand removable working cartridge, no special tools required to service the valve.
15MM 400KPA PA6.341/ 22MM 400KPA PA6.342
400kPa system pressure with integral expansion relief valve.
Copper to Copper SANS 198
Features and Benefits:
Non-corrosive valve seat.
No additional expansion
relief valve required.
Cannot use MLP or SLP for
outside applications.
This is applicable to
PB6.341 (15mm) & PB6.342
I.T.O outlet.
Integral expansion relief valve.
Stainless steel strainer.
Copper to Copper inlet and outlet,
15mm & 22mm respectively.
No special tools required to
replace the cartridge.
PPSU (polyphenylsulfone)
valve seat.
DZR brass die cast.
Ø15mm Copper to Copper
expansion outlet.
System pressure: 400kPa.
Maximum inlet pressure: 2500kPa.
Includes:
Spares:
Masterflo III pressure
Replaceable cartridge C-PA6.832.
control valve.
Cap nut 64XS-22.
Integral expansion relief valve.
Compression ring D-65XS-22.
400kPa cartridge with
stainless steel strainer.
120
100
L/min
80
60
40
20
Flow Pressure
MF3 15mm 400kPa
MF3 22mm 400kPa
100
32
44
200
46
64
300
58
78
400
68
90
500
76
100
600
82
108
0
100
200
300
400
500
600
MF3 15mm 400kPa
MF3 22mm 400kPa
Flow Pressure
SPARE CARTRIDGE 400KPA
Description: 400kPa Pressure control valve cartridge spare part.
Code:
C-PA6.832
SANS198
15MM 600KPA PA6.361/ 22MM 600KPA PA6.362
600kPa system pressure with integral expansion relief valve.
Copper to Copper. SANS 198.
Includes:
Masterflo III pressure control valve.
Integral expansion relief valve.
600kPa cartridge with stainless steel strainer.
Features and Benefits:
Non-corrosive valve seat.
No additional expansion relief valve required.
Cannot use MLP or SLP for outside applications.
This is applicable to PB6.341 (15mm) & PB6.342 I.T.O outlet.
Integral expansion relief valve.
Stainless steel strainer.
Copper to Copper inlet and outlet, 15mm & 22mm respectively.
No special tools required to replace the cartridge.
PPSU (polyphenylsulfone) valve seat.
DZR brass die cast.
Ø15mm Copper to Copper expansion outlet.
System pressure: 600kPa.
Maximum inlet pressure: 2500kPa.
Spares:
Replaceable cartridge C- PA6.862.
Cap nut 64XS-22.
Compression ring D-65XS-22.
120
Flow Pressure
MF3 15mm 600kPa
MF3 22mm 600kPa
100
40
52
200
54
66
300
64
78
400
74
90
500
82
100
600
88
110
100
L/min
80
60
40
20
0
100
200
300
400
500
600
MF3 15mm 600kPA
MF3 22mm 600kPa
Flow Pressure
SPARE CARTRIDGE 600KPA
Description: 600kPa Pressure control valve cartridge spare part.
Code:
C-PA6.862
SANS198
PRESSURE CONTROL VALVES - BASIC INSTALLATION REQUIREMENTS
CAUTION / WARNING:
All installations of products and systems must be in accordance with the applicable
SANS regulations, specifications and standards.
Installations, servicing and maintenance should be done by accredited service
providers only.
A. Balanced Pressure
Hot and Cold water pressure must be balanced (equal pressure) to all mixers, mixing points,
showers and hand showers. This is achieved by taking the cold water supply from the
downstream side of the pressure valve.
B. Valve Identification
100kPa valve (Blue cap)
200kPa valve (Black cap)
400kPa valve (Red cap)
600kPa valve (Green cap)
CAUTION:
The pressure control valve must be compatible with the pressure rating of the
hot water cylinder and the temperature and pressure relief valve (safety valve)
C. Expansion Relief Drain Pipe
Be piped in such a manner to drain downwards
Not be interconnected with the safety valve (T&P) drain pipe
Not to discharge in the hot water cylinder drip tray
Discharge where flow is visible
Be protected against frost
Have minimal bends/ fittings
D. General Requirements
All pipes must be flushed clean before putting the system into operation.
Waterflow must be in the direction of the arrow marked on the valve body.
The valve must be easily accessible for maintenance/ servicing.
The relief drain connection must allow for the relief drain pipe to be pulled to one side when
removing the cartridge. Allow a minimum distance of ±100mm for cartridge removal.
Do not install a stop-cock or non-return valve between the hot water cylinder and the pressure
control valve.
Do not install a stop-cock between the hot water cylinder and the vacuum breakers on the hot
and cold sides.
Supply pipes adequately sized.
Please ensure to make use of copper tube with the installation.
Max inlet pressure 2,500kPa.
System pressure according to the rating of the hot water cylinder, i.e. only use a 400kPa PCV with
a 400kPa rated hot water cylinder and a 600kPa PCV with a 600kPa rated hot water cylinder.
PRESSURE CONTROL VALVES - BASIC INSTALLATION REQUIREMENTS
E. Valve
Valve is pre-set by the factory and does not require any additional adjustments and settings
Integral expansion relief valve
Integral stainless steel strainer
Non-corrosive valve seat
F. Connection Types
Please take note that PCV ranges consist of a variety of connection types and sizes:
15mm Copper to Copper
22mm Copper to Copper
3/4"BSP Female connection end
INSTALLATION OF VALVE AT THE INLET OF THE HOUSE
CLEANING AND MAINTENANCE
Q. When to service?
Insufficient flow rate
Continuous drip through the expansion drain
Flush the cartridge if any dirt or particles are stuck
Replace the cartridge if required
Tighten with your hands or a suitable plumbing tool - DO NOT OVERTIGHTEN THE CAP
PRESSURE CONTROLG VALVES - BASIC INSTALLATION REQUIREMENTS
WARRANTY STATEMENT
All Cobra products are backed by a guarantee against defective materials and workmanship during
the manufacturing process. Our products are backed by a Service Department and, most importantly,
a full range of replacement parts is available from plumber's merchants.
The same commitment that goes into designing and manufacturing a quality product also goes into
ensuring the quality of the service back-up at every stage of design and installation.
THE WARRANTY WILL BE APPLICABLE FOR A PERIOD OF
2 YEARS AGAINST COBRA FACTORY FAULTS.
FAULT FINDER AND PROBLEM SOLVING
COMPLAINT
POTENTIAL FAULT
WHAT TO DO
Excessive water flow at
expansion drain (hot water)
Unbalanced pressure
Balanced pressure
Excessive leak /
continuous drip
Geyser thermostat faulty;
Foreign matter on valve seat;
Valve seat damaged
Clean cartridge / valve;
Replace cartridge;
Check for correct flow in
direction of the arrow
Water hammer during
valve opening / closing
Loose piping;
Air-lock;
System pressure drop;
Excessive water velocity
Secure piping;
Ensure correct pipe sizing;
Vibration in system
Faulty cartridge;
Pipe undersized;
Faulty washer in taps/ mixers
Replace cartridge;
Ensure correct pipe sizing;
Locate and replace washers
Tel: 0861 21 21 21
Email: marketing@cobrawatertech.co.za
www.cobra.co.za
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising