g j _ ~_ 5 I TH115 Series
 Aube Technologies Page 1 of 2
7 THns5 Series
? Packed with advanced
"о programming features, this
e floor heating thermostat
+; offers three choices of
$ temperature control from a
a single model
Print this page
MODELS & RATINGS
TH115-AF-120GA 1800 W@ 120 V 15 A resistive 60 Hz GFCI-5 mA
TH115-AF-120GB 1800 W @ 120 V 15 A resistive 60 Hz GFCI-15 mA
Includes 15 ft. / 4.6 m sensor
SPECIFICATIONS FEATURES
TEMPERATURE CONTROL Three temperature control modes* — ambient (A),
Microprocessor-optimized PIA ambient with floor limit (AF) and floor (F)
Heating cycles: 15 minutes
. 0 0
Accuracy: + 0.5°C /'0.9°F Ground Fault Circuit Interrupter (GFCI) or
Equipment Ground Fault Protection Device
SWITCHING ACTION (EGFPD) included
Epoxy-soundproofed relay: Quiet operation
Test light/button verifies safety cutoff is functioning
PROGRAMMING properly and alerts if a leak is detected
7-day, 4 time periods/day, 2 temp. settings
Pre-programmed or personalized schedule Simple floor sensor connection
Early Start function
Selectable 12- or 24-hour format / °C or °F
Automatic daylight savings adjustment
DIMENSIONS (H*W-+D)
124 x 70 x 23 mm / 4.9 x 2.8 x 0.9 inches ON/STANDBY switch enables thermostat shutdown
Floor sensor: 4.6 m / 15 feet at end of heating season for added security
Advanced temperature control ensures total
comfort by minimizing temperature variations
Temporary bypass enables temperature override
without changing programming
Battery-free backup means no re-programming
your schedule after power outage
ADDITIONAL INFORMATION
“Temperature control modes
Ambient (A) — controls ambient (room) temperature using sensor in thermostat
Ambient with floor limit (AF) — controls ambient (room) temperature with possible limit on floor temperature
http://www.aubetech.com/products/produitsDetails.php?noProduit=30&noLangue=2 3/16/2010
Aube Technologies Page 2 of 2
Floor (F) — controls floor temperature using sensor in floor
GFCI 8 EGFPD safety cutoffs
*GA models meet UL and CSA standards for Class A GFCls
*GA models cut power to the heating system when a 5 mA leak is detected; GB models cut power when a 15
mA leak is detected
See the press release section for an overview of Improvements made to our TH115 Series floor heating
thermostats
ACCESSORIES
Aube AC112-01 North American floor sensor, 15 ft. / 4.6 m
Aube AC112-01 North American floor sensor, 50 ft. / 15 m
Aube CT240 telephone controller
Aube CT241 telephone controller
INSTRUCTION MANUALS
TE) (2006_disc.) TH115-A-F-AF.pdf (format PDF)
LE) TH115-AF GA GB.pdf (format PDF)
19 To view a PDF, you must have Acrobat Reader.
Click on the icon to download it for free.
CERTIFICATION WARRANTY
E e.
с La Tanty
http://www.aubetech.com/products/produitsDetails.php?noProduit=30&noLangue=2 3/16/2010
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising