IC 901 ing - Pro
IC 901
electronic thermostat with single output
THE USER INTERFACE
The user has a display and four keys for
controlling status and programming of the
instrument.
KEYS AND MENUS
UP key
Scrolls through the menu items
Increases the values
DOWN key
Scrolls through the menu items
Decreases the values
FNC key
SET key
fnc
set
ESC function (exit)
Accesses the setpoint
Accesses the menus
Confirms the commands
The instrument has two main menus: the
“Machine Status” and “Programming”
menu.
ACCESSING AND USING MENUS
The instrument is programmed by menus.
To access a menu, press and quickly
release the “SET” key (“Machine status”
menu) or press the “SET” key for over 5
seconds (“Programming” menu).
To access the contents of each folder, indicated by the relevant label, just press the
“SET” key once.
You can now scroll through the contents
of each folder, modify it or use its functions. If you do not use the keyboard for
over 15 seconds (time-out) or if you presence the “FNC” key once, the last value
shown on the display is confirmed and you
return to the previous screen mask.
MACHINE STATUS MENU
To access the “Machine Status “menu,
press and quickly release the “SET” key.
The “Set” folder label appears. To view the
Setpoint value, press the “SET” key again.
The Setpoint value appears on the display.
To change the Setpoint value, use the “UP”
and “DOWN” keys within 15 seconds.
If the parameter is LOC = y the Setpoint
cannot be changed.
PROGRAMMING MENU
To enter the “Programming” menu, press
the “SET” key for more than 5 seconds.
If specified, the access PASSWORD will be
requested, (parameter “PA1”), and the
label of the first folder will follow.
To scroll through the other folders, use
the “UP” and “DOWN” keys.
To enter the folder, press “SET”. The label
of the first visible parameter appears.
To scroll through the other parameters,
use the “UP” and “DOWN” keys. To change
the parameter, press and release “SET”
then set the desired value with the “UP”
and “DOWN” keys, and confirm with the
“SET” key, to move to the next parameter.
COPY CARD
The Copy Card is an accessory that connected to the serial door TTL permits both
fast programming of instrument’s parameters (download), and the possibility to save
the instrument’s parameters (upload) in
order to use them to ri-program other
equivalent instruments. To do this operation enter the folder identified from
label “FPr” and use parameters “UL” or
“dL” depending on the case; to start
uploading (downloading) simply press
“SET” button.
KEYBOARD LOCKING
The instrument includes a facility for disabling the keyboard, by programming the
“Loc” parameter (see folder with “Dis”
label). If the keyboard is locked, you can
still access the programming menu by
pressing the “SET” key.
The Setpoint can also be viewed.
DIAGNOSTICS
The alarm condition is always signalled by
the buzzer (if present) and by the led of
the alarm icon
The alarm signal produced by a faulty
room probe (probe 1) is shown as E1 on
the instrument display 1.
LED
Position
Associated function
Status
Relay 1
ON for relay ON, flashing for delay, disabled protection
or activation
Alarm
ON for an active alarm
INSTALLATION
The instrument is designed for flush panel
mounting. Insert the unit through a
71x29 mm panel cut-out and affix with the
U-bracket supplied.
Select a location which will not be subject
to high humidity or condensation and
allow some ventilation to provide cooling
to the instrument.
ELECTRICAL
CONNECTIONS
Attention! Never work on electrical connections when the machine is switched on.
The instrument is equipped with screw terminal boards for connection of electrical
cables with a diameter of 2.5 mm2 (one
conductor only per terminal for power
connections). For the capacity of the terminals, see the label on the instrument.
Relay outputs are voltage free. Do not
exceed the maximum permissible current
– in case of higher loads, use a contactor
of adequate power. Make sure that the
supplied voltage matches the values specified for the instrument.
In the versions supplied on 12V, the power
supply must be provided via a safety transformer protected by a 250 mA delayed
fuse. The probes do not have any insertion
polarity and can be lengthened by using a
normal bipolar cable (note that if the
probes are lengthened, this will affect the
behaviour of the instrument in terms of
EMC electro-magnetic compatibility –
wiring must be done with great care).
We advise you to keep the probe and supply cables well away from the power
cables.
CONDITIONS OF USE
PERMITTED USE
For safety reasons the instrument must be
installed and used according to the
instruction provided and in particular,
under normal conditions, parts bearing
dangerous voltage levels must not be
accessible.
The device must be adequately protected
from water and dust as per the application
and must also only be accessible via the
use of tools (with the exception of the
frontlet).
The device is ideally suited for use on
household appliances and/or similar refrigeration equipment and has been tested
with regard to the aspects concerning
European reference standards on safety.
It is classified as follows:
o according to its manufacture: as an
automatic electronic control device to be
incorporated by independent mounting;
o according to its automatic operating features: as a 1 B-type operated control type;
o as a Class A device in relation to the category and structure of the software.
The same applies to every individual and
company involved in creating and drawing
up this manual. Invensys Controls Italy
S.r.L. reserves the right to make any
amendment, esthetical or functional, without giving prior notice and at any time.
USE NOT PERMITTED
Any other use other than that permitted is
de facto prohibited. It should be noted
that the relay contacts provided are of a
practical type and therefore subject to
fault. Any protection devices required by
product standards or dictated by common
sense due to obvious safety reasons should
be applied externally.
Frontal panel protection: IP65.
Container: plastic body in resin type
PC+ABS UL94 V-0, inspection window in
polycarbonate, buttons in thermoplastic
resin.
Dimensions: frontal panel 74x32 mm,
depth 60 mm.
Installation: on panel, with template 71x29
mm (+0.2/–0.1 mm).
Ambient temperature: –5…55 °C.
Storage temperature –30…85 °C.
Operating environment humidity: 10…90%
RH (non condening).
Storage environment humidity: 10…90% RH
(non condensing).
Viewing range: –50…99 °C on 2 digit +
mark display.
Analog inputs: one PTC or NTC input
(selectable through parameter).
Digital outputs: one relay output, SPDT
8(3)A 250Va relay or SPDT 15A(1hp)
250Va relay (for capacity relay see label
on the instrument).
Measuring range: from –50 to 99 °C.
Precision: 0.5% better than full scale.
Resolution: 1 °C.
Consumption: according to model.
Power supply: according to model.
See label on instrument.
LIABILITY AND RESIDUAL
RISKS
Invensys Controls Italy S.r.L. shall not be
liable for any damages deriving from:
- installation/use other than that prescribed and, in particular, that which does
not comply with safety standards anticipated by regulations and/or those given herein;
- use on boards which do not guarantee
adequate protection against electric shock,
water or dust under the conditions of
assembly applied;
- use on boards which allow access to dangerous parts without the use of tools;
- tampering with and/or alteration of the
products;
- installation/use on boards not complying
with the standards and provisions of current legislation.
TECHNICAL DATA
DISCLAIMER
This publication is the exclusive property
of Invensys Controls Italy S.r.L. who
absolutely prohibits its reproduction and
distribution unless expressly authorised by
Invensys Controls Italy S.r.L.
Although great care has been taken with
regard to the preparation of this document, Invensys Controls Italy S.r.L. does
not assume any responsibility whatsoever
in relation to its use.
Invensys Controls Italy s.r.l
via dell'Industria, 15 Zona Industriale Paludi
32010 Pieve d'Alpago (BL) ITALY
Telephone +39 0437 986111
Facsimile +39 0437 989066
Internet http:/www.climate-eu.invensys.com
1/2002 ing
cod. 9IS22048
ID 901
2/2
Tab. 1
Parameter description & values table
PARAMETER DESCRIPTION
REGULATOR (folder with “CP”)
Relay regulator tripping differential. The regulator stops on reaching the Setpoint value (as indicated by the adjustment probe), and
restarts at temperature value equal to the Setpoint plus the value
of the differential.
Note: the value 0 cannot be assumed.
Maximum possible setpoint value.
Minimum possible setpoint value.
Heat/Cool Mode. If set to H the generic regulator actuates for hot
operation. If set to C the generic regulator actuates for cold operation
REGULATOR PROTECTIVE DEVICES (folder with “CP” label)
Regulator activation time in the event of faulty probe. If set to “1”
with Oft at “0”, the regulator is always on, while for Oft >0,
it functions always in duty cycle mode.
Regulator in disabled state time in the event of a faulty probe. If
set to “1” with Ont at “0”, the regulator is always off, while at Ont
>0, it functions always in duty cycle mode.
Delay time in activating the regulator relay after switch-on of
instrument.
Delay after switch off. The indicated time must elapse between
switch-off of the regulator relay and the successive switch-on.
Delay between switch-ons. The indicated time must elapse between
two successive switch-ons of the regulator.
delay time in activating the outputs after switch-on of the instrument or after a power failure.
DISPLAY (folder with label “diS”)
Keyboard locking. However, you can enter parameter programming,
modify them and change the status of this parameter to unlock the
keyboard.
y = yes; n = no.
Password 1. When enabled (value other than 0) it constitutes the
access key for level 1 parameters.
Calibration 1. Positive or negative temperature value added to the
value read on the adjustment room probe (probe 1) before being
displayed and used for adjustment.
Selection of °C or °F to view the temperature read by the probe.
0 = °C, 1 = °F.
CONFIGURATION (folder with label “CnF”)
Probe type selection, PTC or NTC. 0 = PTC; 1 = NTC.
Device version. Read only parameter.
Reserved. Read only parameter.
COPY CARD (folder with label “Fpr”)
UpLoad: transferring parameters from instrument to Copy Card.
downLoad: transferring parameters from Copy Card to instrument.
diF
HSE
LSE
HC
Ont
OFt
dOn
dOF
dbi
OdO
LOC
PA1
CA1
dro
H00*
rEL
tAb
UL
dL
U.M.
RANGE
DEFAULT
1...30
2
°C/°F
LSE..99
-55...HSE
H/C
99
-55
H
°C/°F
°C/°F
flag
0...250
0
min
0...250
1
min
0...250
0
sec
0...250
0
min
0...250
0
min
0...250
0
min
n/y
n
flag
0...250
0
num.
-12...12
0
°C/°F
0/1
1
VALUE
flag
0/1
/
/
0
/
/
flag
/
/
/
/
/
/
/
/
* For 230 Va model default value is set to 1 (NTC probe , see label on instrument).
WIRING
1-2
1-3
6-7
8-9
A
IC 901/IC 902 - 12 V
1 2 3
ID 901
6 7 8 9
A
N.C. regulator relay output
N.O. regulator relay output
Power supply
Sensor input
TTL input for Copy Card
A
IC 901/IC 902 - 230 V
1 2 3 6 7
8 9
APPENDIX
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising