Dear Sir, Madam,
Congratulations with your purchase of the Zibro, the number one brand among
movable heaters. You have purchased a first-class quality product, which will
serve you for many years to come. This, of course, provided you use the heater
correctly. Please read these Directions for Use first, to ensure maximum lifetime
for your Zibro.
Your heater comes with a 24-month manufacturer’s warranty on all defects in
material or workmanship.
We wish you much warmth and comfort with your Zibro.
Yours sincerely,
PVG International b.v.
Customer Service Department
1 READ THE DIRECTIONS FOR USE FIRST.
2 IN CASE OF ANY DOUBT, CONTACT YOUR ZIBRO DEALER.
3 BEFORE YOU START READING, FOLD OUT THE LAST PAGE.
4
50
E
E
E
E
E
E
E
E
E
E
GENERAL DIRECTIONS FOR USE
MAIN COMPONENTS
Below you will find the main steps to be taken for
using your Zibro. For more details, please refer to the
A
Front plate
B
Grid
C
Base plate
4
Lid for removable
tank
E
Operation panel
F
Handle
G
Removable tank
H
Air filter
I
Vent filter
J
Thermostat
K
Plug + cord
L
Information display
MANUAL (pages 53 ff.).
1
Remove all packaging materials (Fig. A).
2
Fill the removable tank 7 (refer to Section B, Fig. D).
3
Insert the plug into the wall-socket.
4
5
Ignite the heater using the
key M (refer to Section D).
If required, change the temperature using the adjustment keys
(refer to Section E).
6
Switch off the heater by pressing the
key M.
M
•
The first time you ignite your heater it will smell
like ’new’ for a short time.
•
•
Store your fuel in a cool and dark place.
Childproof lock
O
Adjustment keys
(time and
temperature)
P
TIMER
Q
SAVE key
R
Indicator lights
S
EXTENSION
T
Connection
weektimer
The right quality of fuel will be assured, when you
use Zibro Extra or Zibro Kristal for your heater.
•
N
Fuel has a limited shelf life. Start every heating
season with renewed fuel.
•
key
If you change to another brand and/or type of
parrafin oil, you must first finish up all the
Air quality control
system
remaining fuel in the heater.
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
4
51
E
E
E
WHAT YOU NEED TO KNOW IN ADVANCE
ALWAYS MAKE SURE THAT THERE IS SUFFICIENT VENTILATION
This heater is equipped with an air quality control system
. When there is
insufficient ventilation in the room or when the heater is being used in a room
which is too small, the heater will shut off automatically. For comfortable and safe
heating ensure that there is sufficient ventilation.
Note: To avoid unexpected shut off, we recommend to put a door or window ajar
when the heater is operating.
For each Zibro model the minimum size of space is specified in which you can use
the heater safely, without additional ventilation (refer to Section P). If a particular
Only the use of the
correct fuel will ensure
safe, efficient, and
comfortable use of your
Zibro.
room is smaller than the specified space, always leave a window or door slightly
ajar (± 2.5 cm). We also recommend doing this in highly insulated or draught-free
rooms and/or at altitudes above 1,500 metres. Do not use your Zibro in cellars or
other underground areas.
THE RIGHT FUEL
Only use Class C1 paraffin fuel in accordance with BS2869: Part 2, or equivalent.
Your Zibro heater has been designed for use with high-quality water-free pure
paraffin oil, such as Zibro Extra or Zibro Kristal. Only fuels of this kind will ensure
clean and proper burning. Lower quality fuel may result in:
E
increased possibility of malfunctioning
E
incomplete burning
E
reduced heater lifetime
E
smoke and/or smells
E
deposits on the grid or mantle
Using the right fuel is therefore essential for safe, efficient, and comfortable use
of your heater.
The fuel cap cover can
be found at the rear of
the heater. This cover
allows you to keep your
hands clean when
opening the fuel tank.
This transportation cap
is packed separately in
the box. Only this cap
ensures trouble-free
transportation of the
heater after use.
Store it well!
4
52
Always refer to your local Zibro dealer for the right fuel for your heater.
A
MANUAL
A
E
E
E
E
INSTALLING THE HEATER
1 Carefully remove your Zibro from the box and check the contents.
In addition to the heater you also need to have:
E a manual fuel pump
E a transportation cap
E a fuel cap cover
E these directions for use
Keep the box and the packaging materials (Fig. A) for storage and/or
transportation.
2 Open the lid of the removable tank D and remove the piece of cardboard.
3 Fill the removable tank as indicated in Section B.
4
The floor should be firm and completely level. Reposition the heater, when it
is not level. Do not try to correct the situation by placing books or other
goods under the heater.
5
Insert the plug K into the wall-socket (220/230 Volts - AC / 50 Hz) and set the
correct time using the adjustment keys O (refer to Section C).
B
6 Your Zibro is now ready for use.
B
FILLING FUEL
Do not fill the removable tank in the living room, but in a more suitable place
(there can always be some spillage). Follow the procedure below:
C
1 Make sure that the heater is switched off.
2 Open the lid 4 and lift the removable tank 7 out of the heater (Fig. B).
Note: Some drops may leak from the tank. Put down the removable tank
(cap pointing upwards) and screw off the fuel cap using the fuel cap cover
D
(Fig. C).
3 Take the manual fuel pump and insert the smooth, most rigid tube into the
jerrycan. Make sure that it is in a higher position than the removable tank
(Fig. D). Insert the ribbed hose into the opening of the removable tank.
4 Lock the switch button on top of the pump (turn clockwise).
5 Squeeze the pump a few times, until fuel starts flowing into the removable
tank. As soon as this happens, there is no need to press any longer.
4
53
E
E
6 Check the removable tank fuel gauge G while filling the tank (Fig. E). Stop
E
filling by loosening the switch button on top of the pump (turn anti-clockwise), once the gauge indicates that the tank is full. Never overfill the tank,
especially not when the fuel is very cold (fuel expands when it heats up).
empty
full
7 Let the remaining fuel in the pump flow back into the jerrycan and carefully
remove the pump. Carefully screw the fuel cap back on the tank using the
fuel cap cover. After use, re-store the cover at the rear of the heater. Clean
off any spilled fuel.
8 Check whether the fuel cap is straight and tightened properly. Reinstall the
removable tank in the heater (cap down). Close the lid.
C
SETTING THE CLOCK
It is only possible to set the correct time, when the heater is connected to the
mains and not burning. Use the adjustment keys O to set the time. First press
either of the two keys to switch on the function (the CLOCK light and the
information display L will start blinking). Next, set the hours using the key on the
left (
Nhour) and the minutes using the key on the right (Mmin.). Press once to
increase the value by one step. When you hold down the key, the value will
F: When the CLOCK
indicator light stops
blinking, the setting has
been locked to the
indicated value.
continue going up, until you release the key again. After approximately 10
seconds the blinking will stop and the setting will be locked. 5 minutes after
switching off the heater, the information on the display will disappear and the
heater will automatically switch into the stand-by position.
☞
D
When the heater has been unplugged for more than 10 minutes (or after a
power failure), the time needs to be set again.
IGNITING THE HEATER
When used for the first time, a new heater may give out a smell for a short while.
You should therefore provide extra ventilation.
Always ignite the heater with the
lighter. Just press the
button M. Never use matches or a cigarette
button M to ignite the heater. The button will start
blinking, indicating that the ignition procedure has started. This will take a short
while. Once the heater is burning, the
button M will remain lit (red). The
information display L will show two numbers. The light next to them indicates
that these numbers refer to the temperatures (Fig. G). The actual room
G: The required
temperature on the left,
the measured
temperature on the
right.
temperature is indicated below ROOM, while the temperature setting is indicated
below SET. The latter can be changed with the adjustment keys (refer to Section E).
Prior to igniting the heater, always check for sufficient fuel in the removable tank.
E
SETTING THE REQUIRED TEMPERATURE
The temperature setting can only be adjusted, when the heater is burning. Use the
adjustment keys O to adjust the temperature. First press either of the two keys to
switch on the function (the TEMP light next to the information display L will start
Mmin.) to set
Nhour) to lower the
blinking). Next, adjust the temperature using the key on the right (
the temperature to a higher setting and the key on the left (
4
54
temperature. Press once to increase the value one step. After approximately 10
seconds the light will stop blinking and the setting will be locked (Fig. G).
The available temperature settings range from 6°C minimum to 28°C maximum.
When the heater has been unplugged for more than 10 minutes (or after a power
failure), the temperature will reset to the factory setting of 20°C.
F
USING THE TIMER
The timer allows you to switch on the heater automatically at a preset time.
In order to switch on the timer, the correct time must have been set (refer to
Section C) and the heater should be off. Follow the procedure below:
1 Press the
button M and then the TIMER key P immediately after that.
The TIMER light and the information display L will start blinking.
2 Use the adjustment keys O to set the time at which the heater must ignite.
Use the key on the left (
M
Nhour) to set the hours and the key on the right
( min.) to set the minutes (interval of 5 minutes).
3 After approximately 10 seconds the information display will show CLOCK
again and the TIMER indicator light will light up, indicating that the timer
function has been activated (Fig. H).
H: The TIMER indicator
light indicates that the
timer function has been
switched on.
4
The timer will ensure that the room will have been heated to approximately
the required temperature at the set time.
☞
When you want to switch off the heater and ignite it again with the timer, all
you have to do is press the TIMER key (refer to Section G).
Press the
☞
G
button M once to clear the timer setting.
If you would like more extensive timer possibilities, we advise you to procure
the Zibro weektimer. This timer is easy to connect with your Zibro Heater, see T.
SWITCHING OFF THE HEATER
There are two ways to switch off the heater.
1 Press the
button M. The information display will show the CLOCK
signal. Within approximately one minute the flame will have extinguished.
2 Press the TIMER key P, when you want to switch off the heater and ignite it
again with the timer the next time. This not only switches off the heater, but
it also activates the timer function. You can change the required time with the
adjustment keys O (refer to Section F).
H
THE INFORMATION DISPLAY
The information display L not only serves as an indicator of the (set) time and
temperature (Sections C, E, and F), it also indicates any malfunctioning of the
heater. The code on the information display tells you what is the matter:
4
55
CODE
efefeeee-
In case of any
malfunctioning the
information display will
tell you what is the
matter.
0
0
1
1
2
5
6
7
e- 8
e- 9
-: -(& blinking
INFORMATION
Temperature within the heater too high.
Power interrupted.
Faulty thermostat.
Faulty burner thermistor.
Starting problems.
Tipping-over protection.
Poor burning.
Room temperature
above 32°C.
Defective booster.
Air filter dirty; or
Fuel pump dirty.
The heater has been in operation
continuously for a period of 91 hours
and has turned itself off automatically.
Out of fuel.
WHAT TO DO
Cool-down and re-ignite.
Re-ignite the heater.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Re-ignite the heater.
Contact your dealer.
If necessary,
re-ignite the heater.
Contact your dealer.
Clean filter
Contact your dealer.
Switch the heater back on.
Refill removable tank.
Too little ventilation.
Ventilate better.
Too little ventilation.
Ventilate better.
FUEL-light)
-: -(& blinking
VENT-light)
e-11
(& blinking
VENT-light)
Always contact your Zibro dealer for any malfunctioning not listed above.
AUTOMATIC DEACTIVATION
This heater is fitted with a safety system that ensures that it switches off
automatically after 91 hours continuous operation. The following will then appear
in the display:
the
. If desired, you can switch the heater on again by pressing
button M (see Section D).
AUTOMATIC CLEANING MODE
When te heater has been burning continuously for two hours at its highest
setting, the burner will automatically start an autoclean procedure. The display
will show the autocleaning code cl:05 running back to cl:01. The procedure takes 5
minutes, during which the heater will burn at its lowest setting, while the burner
autocleans. When the burner is clean again, the heater will automatically switch
back to the highest setting again.
I
CHILDPROOF LOCK
The childproof lock can be used to prevent children accidentally changing the heater
settings. When the heater is burning and the childproof lock is on, the heater can
only be switched off. Other functions are blocked then. If the heater has already
been switched off, the childproof lock also prevents accidental ignition of the
heater. Activate the childproof lock by pressing the appropriate key N and holding it
I: When the KEY-LOCK
light lights up, the
childproof lock has been
activated.
down for more than 3 seconds. The KEY-LOCK indicator light will light up (Fig. I),
indicating that the childproof lock has been activated. Switch off the childproof lock
by pressing the key N and holding it down for more than 3 seconds once again.
J
4
56
THE CORRECT USE OF 'SAVE'
The 'SAVE' function allows you to limit the temperature. When this function is
activated, the heater will automatically switch off, when the room temperature exceeds
the set temperature by 3°C. Subsequently, when the room temperature has dropped
again to the set temperature, the heater will automatically switch on again. Activate
the 'SAVE' setting by pressing the appropriate Q key. The SAVE indicator light will
light up (Fig. J). Switch off the function by pressing the SAVE key once again.
Without the 'SAVE' setting your heater will maintain the set temperature by
☞
J: When the SAVE light
lights up, the heater will
automatically switch on
or off in order to remain
within a specified
temperature range.
approximation as well, by adjusting its heating capacity. 'SAVE' is an economy
setting, which you can use when, for instance, you are not present in the room
or to keep it frost-free.
K
THE 'FUEL' INDICATOR LIGHT
When the indicator light FUEL lights up, it means that there is only fuel left for 10
more minutes. The count-down of the remaining heating time can be seen in the
information display L (Fig. K). Now you have two options:
E
you remove the fuel tank and refill it outside the living room (section B) or
E
you push the button EXTENSION S. By pushing this button, the remaining
heating time will extend to 90 minutes. The heater will automatically switch
K: When the FUEL
indicator light is lit, the
information display will
show the number of
minutes of fuel left in
the tank.
back to its lowest position. In the display the number 90 will appear, which
will decline to 10. At the arrival of 10, you will hear an alarmsignal every two
minutes, warning you to refill the removable tank. If you do not react, the
heater will extinguish by itself. The heater will also sound a warning signal,
when it switches off. The fuel indicator light will blink, while four lines (--:--)
are blinking in the information display. You can stop this by pressing the
button M once more.
Once the heater has used up all its fuel and extinguished, it will take some time,
after the refill, before the heater is completely ready for use again.
L
THE 'VENT' INDICATOR LIGHT
When there is insufficient ventilation in the room, an intermittent buzzer will be
heard (approximately once each 30 seconds) and the VENT indicator will be lit.
When this signal is given, ensure that the ventilation of the room is improved (e.g.
by opening a door or window a little more), to avoid that the heater shuts off.
When the ventilation of the room is improved, the VENT indicator and buzzer will
L: A blinking VENT
indicator light is a sign
that you need extra
ventilation.
be deactivated. When there is still insufficient ventilation, the heater shuts off
automatically. When this occurs, e -1 1 is displayed and the VENT indicator is
blinking. After improving the ventilation of the room (e.g. by opening a door or
window a little more), the heater can be ignited by pushing
M again.
If the indicator light continues blinking after extra ventilation, please contact your
Zibro dealer.
M
MAINTENANCE
Switch off the heater and let it cool down, before you start any maintenance
M
work. Also disconnect the plug from the mains. Your Zibro needs hardly any
maintenance. It is, however, important that you clean the air filter 8 and the vent
filter 9 with a vacuum cleaner and the grid 2 with a damp cloth, both on a
weekly basis. Remove the air filter cap occasionally (Fig. M) and clean it with soapy
water. Prior to reinstallation, make sure that the air filter cap has fully dried.
Regularly inspect the fuel filter as well:
4
57
1 Remove the removable tank 7 from the heater and remove the fuel filter
(Fig. N). Some drops may leak from the filter; keep a cloth at hand.
Fuel filter
N
2 Remove the dirt by tapping the fuel filter upside-down against a hard surface.
(Never clean it with water!)
3 Reinstall the fuel filter into the heater.
We recommend that you remove dust and stains in time with a damp cloth,
because otherwise these may cause stains that are hard to remove.
☞
N
Do not remove any heater components yourself. Always contact your Zibro
dealer for repairs. When the power cord is damaged, it may only be replaced
by an authorised fitter. Use a new cord of the type H05 VV-F.
STORAGE (END OF THE HEATING SEASON)
At the end of the heating season, you must store the heater in a dust-free place, if
possible in its original packaging. Unused fuel cannot be used in the next heating
season. We therefore recommend that you burn up all fuel. If there is still some
fuel left, do not throw it away, but dispose of it in accordance with the local
regulations for the disposal of domestic chemical waste. Always start the new
heating season with fresh fuel. When you start re-using the heater follow the
instructions again (starting from section A and as specified).
O
TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
O
1 Let the heater cool down.
2 Remove the removable tank G from the heater and remove the fuel filter
(refer to Section M, Fig. N). Some drops may leak from the filter; keep a cloth
at hand. Store the fuel filter and the removable tank outside the heater.
3 Place the transportation cap into the position of the fuel filter (Fig. O).
Press it tight.
transportation cap
4 Always move the heater in an upright position.
P
4
SPECIFICATIONS
Ignition
electrical
Dimensions (mm)
width
435
Fuel
paraffin
(including base plate) depth
315
Capacity (kW) max.
3.20
height
437
Capacity (kW) min.
0.80
Accessories
manual fuel pump
50-130
Suitable space (m3)**
fuel cap cover, transportation cap
0.333
Mains
220V/230V
Fuel consumption (l/hr)*
267
-- AC/50 Hz
Fuel consumption (g/hr)*
23
Electrical consumption igniter
320 W
Burning time per tank (hr)*
Capacity removable tank (litres) 7.6
continuous 31 W
250V, 5A
Fuse rating
11.5
Weight (kg)
Monitoring of the quality of ventilation (air renewal):
Direct measurement of the CO2 level (NDIR CO2-sensor E-Guard
).
* At maximum setting
58
** Specified values are indicative
Q
WARRANTY PROVISIONS
Your heater comes with a 24-month warranty starting on the date of purchase.
Within this period all defects in material or workmanship will be repaired without
any charge. The following provisions shall apply regarding this warranty:
1 We expressly dismiss all other claims for damages, including consequential
damages.
2 Any repairs or replacements of components within the term of warranty will
not result in an extension of the term of warranty.
3 The warranty shall no longer apply, when the heater has been modified,
non-original parts have been used, or when it is repaired by third parties.
4 The warranty shall not apply to parts that are subject to normal wear, such as
the burner mat and the manual fuel pump.
5 The warranty shall only apply, when you present the original, dated proof of
purchase, provided no changes have been made to it.
6 The warranty shall not apply to damages caused by actions not in compliance
with the Directions for Use, neglect, and the use of an incorrect type of fuel,
or fuel past its use-by date. The use of incorrect fuel can even be dangerous*.
7 Transportation costs and the risks involved during the transportation of the
heater or heater components shall always be for the account of the purchaser.
In order to avoid unnecessary costs, we recommend that you always read the
’Directions for Use’ carefully first. In case they offer no solution, please take the
heater to your dealer for repair.
* Highly inflammable substances may induce uncontrollable burning, causing flames to break out. Should this
happen, never try to move the heater, but always switch off the heater immediately. In case of emergency you
may use a fire extinguisher, but only a type B extinguisher: a carbon dioxide or powder extinguisher.
10 TIPS FOR SAFE USE
1
2
3
4
5
6
7
8
9
10
Make sure that children are always aware of the presence of a burning
heater.
Do not move the heater when it is burning or still hot. Do not refill nor
service the heater when it is burning or still hot.
Position the front of the heater at a distance of minimum 1.5 metres
from walls, curtains, and furniture.
Do not use the heater in dusty rooms. You will not have optimum
burning in such rooms. Do not use the heater in the immediate
surrounding of a bath, a shower or a swimmingpool.
Switch off the heater, before you leave or go sleeping. Unplug the
heater as well, when you go away for a longer period of time
(e.g. holidays).
Store and move fuel only in suitable tanks and jerrycans.
Make sure that the fuel is not exposed to heat or extreme temperature
changes. Always store the fuel in a cool, dry and dark place (sunlight
will affect the quality).
Never use the heater in places where harmful gasses or fumes may be
present (e.g. exhaust gasses or paint fumes).
Beware that the grid of the heater becomes hot. If the appliance is
covered there is a risk of fire.
Always make sure that there is sufficient ventilation.
Defective electrical devices and batteries must be kept separate from household
waste. Ensure that there is effective recycling where possible. Ask you local council
or dealer for expert advice on recycling.
4
59
AFAQ AFNOR CERTIFICATION 11, AVENUE FRANCIS DE PRESSENSE
93571 SAINT-DENIS LA PLAINE CEDEX
FICHE INFORMATIVE
La marque NF garantit
la qualité de cet article
suivant les normes françaises
et Règles de certification
de l’application NF 128
CHAUFFAGES MOBILES
A COMBUSTIBLE LIQUIDE
NF 128 02 / 02
CONFORME A LA NORME NF D 35-300 ET AUX SPECIFICATIONS
COMPLEMENTAIRES DEFINIES PAR LES REGLES
DE CERTIFICATION DE L’APPLICATION NF 128
PRINCIPALES CARACTERISTIQUES CERTIFIEES:
• Sécurité du dispositif d’allumage
• Débit calorifique
• Efficacité des dispositifs de sécurité
• Stabilité
• Contrôle de la teneur en NOx dans les produits de combustion
• Contrôle de la qualité de la combustion (absence de CO)
• Endurance
• Intermittence
CONSEILS D’UTILISATION ET D’ENTRETIEN
Se reporter à la notice jointe à l’appareil et à la plaque de sécurité sur
l’appareil
Référence et numéro de lot ou de série de l’article : se reporter au produit
Distributed in Europe by:
PVG International B.V.
P.O.Box 96, 5340 AB OSS
Pays-Bas Tél.: +31 (0) 412 694670
En cas d’insatisfaction, consultez d’abord :
En France: PVG France SARL
4, Rue Jean Sibélius, B.P. 185
76410 SOTTEVILLE SOUS LE VAL
Tél.: 02.32.96.07.47 – Fax: 02.32.96.07.77
E
E
E
E
E
E
E
E
Si une difficulté subsistait, vous pouvez écrire au LNE
LABORATOIRE NATIONAL DE MÉTROLOGIE ET D’ESSAIS
Division
E
E
E Certification
E
E plurisectorielle
E
E
E
E
1, Rue Gaston Boisier - 75724 PARIS CEDEX 15
E
E
E
E
E
E
E
G
D
E
F
A
I
B
J
T
H
C
K
E
R
L
N
E
E
E
Q
E
E
O
P
E
E
E
E
E
E
E
M
S
E
E
E
E
E
E
E
E
E
E
E
E
E
DISTRIBUTED IN EUROPE BY PVG INTERNATIONAL b.v.
2 DEUTSCHLAND
PVG Deutschland GmbH
Siemensstrasse 31
47533 KLEVE
tel:
0800 - 9427646
fax:
+31 (0)412 648 385
email: pvgdeutschland@zibro.com
6 DANMARK
Appliance A/S
Blovstroed Teglvaerksvej 3
DK-3450 ALLEROED
tel:
+45 70 205 701
fax:
+45 70 208 701
email: appliance@appliance-group.com
5 ESPAÑA
PVG España S.A.
Pol. Ind. San José de Valderas II
Comunidad ”La Alameda”
C/ Aurora Boreal, 19
28918 LEGANÉS (Madrid)
tel:
+34 91 611 31 13
fax:
+34 91 612 73 04
email: pvgspain@zibro.com
3 FRANCE
PVG France SARL
4, Rue Jean Sibélius
B.P. 185
76410 SOTTEVILLE SOUS LE VAL
tel:
+33 2 32 96 07 47
fax:
+33 0 820 34 64 84
email: pvgfrance@zibro.com
FIN
SUOMI
Appliance Finland Oy
Piispantilankuja 6C
02240 ESPOO
tel:
+358 9 4390 030
+358 9 4390 0320
fax:
email: appliance@appliance-group.com
New 7/07
> ITALIA
PVG Italy SRL
Via Niccolò Copernico 5
50051 CASTELFIORENTINO (FI)
tel:
+39 571 628 500
fax:
+39 571 628 504
email: pvgitaly@zibro.com
u NORGE
Appliance Norge AS
Vogellunden 31
1394 NESBRU
tel:
+47 667 76 200
fax:
+47 667 76 201
email: appliance@appliance-group.com
1 NEDERLAND
PVG International B.V.
P.O. Box 96
5340 AB OSS
tel:
+31 412 694 694
fax:
+31 412 622 893
email: pvgnl@zibro.com
9 PORTUGAL
Gardena, Lda
Recta da Granja do Marquês
ALGUEIRÃO
2725-596 MEM MARTINS
tel:
+ 35 21 92 28 530
fax:
+ 35 21 92 28 536
email: pvgint@zibro.com
: POLSKA
PVG Polska Sp. z. o. o.
ul. Kościelna 110
26-800 Białobrzegi
tel:
+48 48 613 00 70
fax:
+48 48 613 00 70
email: pvgpoland@zibro.com
= SVERIGE
Appliance Sweden AB
Sjögatan 6
25225 HELSINGBORG
+46 42 287 830
tel:
fax:
+46 42 145 890
email: appliance@appliance-group.com
man_SRE168E
q SCHWEIZ
PVG Schweiz AG
Salinenstrasse 63
4133 PRATTELN
tel:
+41 61 337 26 51
+41 61 337 26 78
fax:
email: pvgint@zibro.com
Scott Brothers Ltd.
The Old Barn, Holly House Estate
Cranage, Middlewich, CW10 9LT UK
tel.:
+44 1606 837787
+44 1606 837757
fax:
sales@scottmail.co.uk
email:
TR
TURKEY
PVG Is›tma Klima So¤utma Ltd.fiti.
Atatürk Cad. No 380 Ak Iflhani Kat 6
35220 Alsancak
IZMIR - TURKEY
tel:
+ 90 232 463 33 72
+ 90 232 463 69 91
fax:
email: pvgturkey@zibro.com
avg©070521
e BELGIË
PVG Belgium NV/SA
Industrielaan 55
2900 SCHOTEN
tel:
+32 3 326 39 39
fax:
+32 3 326 26 39
email: pvgbelgium@zibro.com
4 UNITED KINGDOM
PVG Traffic
i ÖSTERREICH
PVG Austria VertriebsgmbH
Salaberg 49
3350 HAAG
tel:
+43 7434 44867
fax:
+43 7434 44868
email: pvgaustria@zibro.com
Printed in Japan
7827001921
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising