PA402-01-01 (SPEC)
Specification
Model : NLS5000-160
Vo
160
V
31.25
A
0
A
5000
W
90
%
187 ~ 264VAC, 47 ~ 63Hz
30
A
30 @ Cold Start
A
0.99
1
% p-p
0.5
%
0.5
%
0.02
% / °C
102
%
176 ~ 192
V
Yes
Yes
2
s
Yes
Yes
Yes
0~+50, 20~95 (Non-condensing)
°C,%RH
-25~+85, 20~95 (Non-condensing)
°C,%RH
Internal Forced Air
Input - Output … 2121VDC 5sec. Input - Chassis … 2121VDC 5sec.
Designed to meet EN55022, Level A
UL60950-1, CSA60950-1 & EN60950-1
<8
kg
inch
5 x 5 x 17 (Refer to outline drawing)
mm
127 x 127 x 432 (Refer to outline drawing)
1 year
No.
Items
Unit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
Nominal Output Voltage
Maximum Output Current
Minimum Output Current
Max Output Power
Efficiency (typ)
Input Voltage & Frequency Range
Input Current (typ)
Inrush Current (typ)
Power Factor (typ)
Ripple & Noise (max)
Line Regulation (max)
Load Regulation (max)
Temperature Coefficient (max)
Over Current Protection (min)
Over Voltage Protection
Remote Sensing
Over Temperature Protection
Turn On Time (max)
Remote ON/OFF
Power Fail Signal (Loss Of AC)
Output Power Good (Loss Of DC Output)
Operating Temperature, Humidity
Storage Temperature, Humidity
Cooling
Withstand Voltage
EMI (Radiated & Conducted Emission)
Safety Standard
Weight
Size (W x H x D)
30
Warranty
Note :
*1. At Vin = 230VAC, 80% load & Ta=25°C.
*2. At Vin = 230VAC, maximum output power (unless otherwise specified) & Ta=25°C.
*3. Bandwidth of scope : 20MHz
*4. From Vin = 187 ↔ 264Vac, constant load.
*5. From 0% load ↔ 100% load, constant input voltage.
*6. From Ta = 0 → 50°C.
*7. Constant current limit with automatic recovery.
*8. Output shut down & to be reset by AC re-cycle.
*9. Measure from the time AC is turn on.
*10. More than 2V or open circuit will inhibit the supply. Less than 0.5V will enable the supply.
*11. Upon loss of AC line, signal pulls low before loss of output regulation. LED on is AC good & off is fault condition.
No internal pull up is provided.
*12. Signal pulls low when output drops more than 15% ± 5% of the nominal. LED on is DC good & off is fault condition.
No internal pull up is provided.
*13. Exclude the I/O Connectors.
(*1)
(*2)
(*2)
(*3)
(*4)
(*5)
(*6)
(*7)
(*8)
(*8)
(*9)
(*10)
(*11)
(*12)
(*13)