datasheet - Lite-On Power System Solutions
UP-3602, UP-3103
DATASHEET
AC Uninterruptible Power Supply
The Lite-On AC Uninterruptible Power Supply (UPS) provides clean, reliable AC power to mission-critical
devices such as networks, computers, or servers.
Key Features
•
•
•
•
•
•
•
•
•
•
True double-conversion online UPS
DSP technology
Output power factor 0.8
Active input power factor correction
of 0.99
Adjustable charging current via LCD or
software (0.5A – 6A)
Wide input voltage range (110 –
300 VAC)
50/60 Hz frequency converter mode
Emergency Power OFF Function (EPO)
Maintenance bypass available
SNMP / USB / RS-232 communications
Specifications
UP-3602
Electrical Input
Total Power
Phase
Nominal Voltage
Voltage Range
Frequency Range
Power Factor
Nominal Voltage
Voltage Regulation
Frequency Range AC Mode
Frequency Range Battery
Mode
Load Crest Factor
Voltage Distortion (THDv)
Transfer Time (bypass to line
mode)
Transfer Time (line Mode to
bypass)
Waveform
6kVA / 4.8kW
10kVA / 8kW
1-phase 2 wires with earth ground
208V / 220V / 230V / 240V
110 – 300VAC at 50% Load; 176 – 300VAC at 100% Load
46Hz – 54Hz or 56Hz – 64Hz
≧ 0.99 at 100% Load
Electrical Output
208V / 220V / 230V / 240V
± 1%
50Hz ± 4Hz or 60Hz ± 4Hz
50Hz ± 0.1Hz or 60Hz ± 0.1Hz
3:1 (maximum)
< 3% (Linear load), < 10% (Non-linear load)
0 mS
0 mS
Pure Sinewave
Lite-On Power System Solutions USA
3001 Summit Ave, Suite 400, Plano, TX 75074
+1 (469) 331-9838
www.liteon-pss.com
email: pss.sales@liteon.com
UP-3602_UP-3103-DS-02
UP-3103
Lite-On Power System Solutions Taiwan
No. 90, Chien 1 Rd., Chung Ho Dist, New Taipei City 23585
+886 -2-2226181 ext 5026
www.liteon-pss.com
email: pss.sales@liteon.com
Page 1 of 8
September 2015
UP-3602, UP-3103
DATASHEET
AC Uninterruptible Power Supply
Specifications
Electrical Efficiency
AC Mode
Battery Mode
Indicators
LCD Panel
Alarm
Battery Mode
Low Battery
Overload
Fault
External Battery Pack
(BK-1181-010M)
Battery Type
Quantity
Typical Recharge Time
Backup Time
Charging Current
Floating Charge Voltage
Physical (UPS)
Dimensions (H x W x D)
Net Weight
Form Factor
Physical (Battery)
Dimensions (H x W x D)
Battery Pack Net Weight
Form Factor
Environment
Acoustic
Operating Temperature
Storage Temperature
Humidity
Altitude
UP-3602
UP-3103
89%
88%
90%
89%
UPS status, Load level, Battery level, Input / Output voltage,
Discharge timer, and Fault conditions
Audio alarm every 4 seconds
Audio alarm every second
Audio alarm twice every second
Continuous Audio alarm
12V / 9AH
20 pcs
4 hours to recover to 90% capacity
> 8 mins @ 20 pcs batteries
> 4 mins @ 20 pcs batteries
Default: 2.0A
13.65 V/pc (floating charge with constant voltage)
3.4″ x 17.2″ x 22.8″
(86.5 mm x 438 mm x 580 mm)
33 lbs (15 kg)
2U
5.2″ x 17.2″ x 22.8″ (131 mm x 438 mm x 580 mm)
143.3 lbs (65 kg)
3U
Less than 55dBA @1 m
Less than 58dBA @1 m
0°C – 40°C
-15°C – 60°C (UPS), 0°C – 35°C (Battery Bank)
0% – 95% relative (non-condensing)
< 1000 m
Lite-On Power System Solutions USA
3001 Summit Ave, Suite 400, Plano, TX 75074
+1 (469) 331-9838
www.liteon-pss.com
email: pss.sales@liteon.com
UP-3602_UP-3103-DS-02
3.4″ x 17.2″ x 26″
(86.5 mm x 438 mm x 660 mm)
39.7 lbs (18 kg)
Lite-On Power System Solutions Taiwan
No. 90, Chien 1 Rd., Chung Ho Dist, New Taipei City 23585
+886 -2-2226181 ext 5026
www.liteon-pss.com
email: pss.sales@liteon.com
Page 2 of 8
September 2015
DATASHEET
UP-3602, UP-3103
AC Uninterruptible Power Supply
Specifications
UP-3602
General
Approvals
Mounting Hardware
Warranty
UP-3103
CE
2 mounting ear and 8 screws are included
2 years (UPS) / 1 year (Battery bank)
Mechanical
UP-3602
units in mm
Lite-On Power System Solutions USA
3001 Summit Ave, Suite 400, Plano, TX 75074
+1 (469) 331-9838
www.liteon-pss.com
email: pss.sales@liteon.com
UP-3602_UP-3103-DS-02
Lite-On Power System Solutions Taiwan
No. 90, Chien 1 Rd., Chung Ho Dist, New Taipei City 23585
+886 -2-2226181 ext 5026
www.liteon-pss.com
email: pss.sales@liteon.com
Page 3 of 8
September 2015
DATASHEET
UP-3602, UP-3103
AC Uninterruptible Power Supply
UP-3103
units in mm
Lite-On Power System Solutions USA
3001 Summit Ave, Suite 400, Plano, TX 75074
+1 (469) 331-9838
www.liteon-pss.com
email: pss.sales@liteon.com
UP-3602_UP-3103-DS-02
Lite-On Power System Solutions Taiwan
No. 90, Chien 1 Rd., Chung Ho Dist, New Taipei City 23585
+886 -2-2226181 ext 5026
www.liteon-pss.com
email: pss.sales@liteon.com
Page 4 of 8
September 2015
DATASHEET
UP-3602, UP-3103
AC Uninterruptible Power Supply
Front Panel
LCD Panel
Mode indicator panel
LED indicators
LED indicators show the working status of the UPS
•
ON / ENTER
•
•
MUTE / DOWN
•
•
TEST / UP
•
•
OFF / ESC
•
Turn on the UPS: press and hold this button longer
than 0.5 second to turn on the UPS
Enter Key: press to confirm the selection in the menu
Mute the alarm: Press and hold this button longer than
0.5 second to mute the buzzer
Down key: Press this button to display previous
selection in setting menu
Battery test: press and hold this button longer than
0.5 second to test the battery while in AC mode, or
CVCF mode
UP key: press this button to display next selection in
setting menu
Turn off the UPS: press and hold this button longer
than 0.5 second to turn off the UPS
ESC key: press this button to return to last menu in
setting menu
Lite-On Power System Solutions USA
3001 Summit Ave, Suite 400, Plano, TX 75074
+1 (469) 331-9838
www.liteon-pss.com
email: pss.sales@liteon.com
UP-3602_UP-3103-DS-02
Lite-On Power System Solutions Taiwan
No. 90, Chien 1 Rd., Chung Ho Dist, New Taipei City 23585
+886 -2-2226181 ext 5026
www.liteon-pss.com
email: pss.sales@liteon.com
Page 5 of 8
September 2015
DATASHEET
UP-3602, UP-3103
AC Uninterruptible Power Supply
Rear Panel
External battery connector
Connector for one or more battery modules
RS-232 communication port
The serial port may be used to connect UPS to a
workstation or server
Intelligent slot
Removable cover panel to install optional accessories to
remotely control and monitor UPS system
USB communication
USB port may be used to connect UPS to a workstation or
server
EPO connector
Emergency Power Off connector
Cooling fans
Cools and ventilates the power module
Input circuit breaker
Input circuit breaker
Terminals (shown without cover)
Input / Output terminals
EMBS port
External maintenance bypass switch port
Lite-On Power System Solutions USA
3001 Summit Ave, Suite 400, Plano, TX 75074
+1 (469) 331-9838
www.liteon-pss.com
email: pss.sales@liteon.com
UP-3602_UP-3103-DS-02
Lite-On Power System Solutions Taiwan
No. 90, Chien 1 Rd., Chung Ho Dist, New Taipei City 23585
+886 -2-2226181 ext 5026
www.liteon-pss.com
email: pss.sales@liteon.com
Page 6 of 8
September 2015
UP-3602, UP-3103
DATASHEET
AC Uninterruptible Power Supply
System Components
Component
ALTOCUM 6kVA
UPS
ALTOCUM 10kVA
UPS
Battery Pack for
ALTOCUM UPS
SNMP card
Rail kit
(basic type)
Manual bypass
switch
Model Number
Description
UP-3602-301M
6kVA rack UPS
UP-3103-301M
10kVA rack UPS
BK-1181-010M
Rack Battery Pack for ALTOCUM (VRLA battery 20 pcs)
CM-12EU-010U
Accessories
SNMP web card
UZ-M001-000U
Basic type rail kit (700mm)
UZ-E001-000M
Maintenance bypass switch for 6kVA/10kVA (63A)
Lite-On Power System Solutions USA
3001 Summit Ave, Suite 400, Plano, TX 75074
+1 (469) 331-9838
www.liteon-pss.com
email: pss.sales@liteon.com
UP-3602_UP-3103-DS-02
Lite-On Power System Solutions Taiwan
No. 90, Chien 1 Rd., Chung Ho Dist, New Taipei City 23585
+886 -2-2226181 ext 5026
www.liteon-pss.com
email: pss.sales@liteon.com
Page 7 of 8
September 2015
DATASHEET
UP-3602, UP-3103
AC Uninterruptible Power Supply
Innovative Power Management Solutions for Critical Infrastructure
Lite-On Power System Solutions USA
3001 Summit Ave, Suite 400, Plano, TX 75074
+1 (469) 331-9838
www.liteon-pss.com
email: pss.sales@liteon.com
UP-3602_UP-3103-DS-02
Lite-On Power System Solutions Taiwan
No. 90, Chien 1 Rd., Chung Ho Dist, New Taipei City 23585
+886 -2-2226181 ext 5026
www.liteon-pss.com
email: pss.sales@liteon.com
Page 8 of 8
September 2015
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project