RTU-D Cafeteria, RTU..
Date
05/24/2011
Project Name
Douglas Middle School
Project Number
Client / Purchaser
Submittal Summary Page
Qty
1
Tag #
RTUCafeteria
1
1
1RC0478
RTUClassroom
A&B
1
1
Model #
J15ZJC00Q4TZZ1
V34AW24R8KCXAU
1RC0455P
RTUJ12ZHC00Q4TZZ5
Administratio
n
1
Unitary Sales Tool v1.5.2.0
1RC0471
Description
15 Ton, Johnson Controls Series 20 Single Packaged R-410A Air
Conditioner, 12.4 EER / 13.9 IPLV, No Factory Installed Heat, 5 HP
High Static Belt Drive Blower, 2" Throwaway Filters, 460-3-60, Copper
Tube/Aluminum Fin Condenser Coil
• Dry Bulb Economizer w/Power Exhaust and Hoods (Bottom return
only)
• Powered Convenience Outlet (110 VAC / 15 Amp)
• Non Fused Disconnect Switch
• Coil Guard
• Dirty Filter Indicator Switch
• Stainless Steel Drain Pan
• Double Wall Cabinet
• Hinged & Tool Free Filter, Blower, Motor and Electrical Access
Panels
• VAV Controller with VFD, Manual Bypass & SimplicityLINC (BACnet
MS/TP Protocol)
• Hot Gas Bypass
Roof Curb - 24" High, Flat, Uninsulated, Full Perimeter (Shipped
Knocked Down Vendor Direct) (Required on units with ERV size 36 &
above)
Johnson Controls Series 40 Single Packaged R-410A Air Conditioner,
40 Ton, Bottom Return, Bottom Supply, Hot Water Coil, 2 Rows Hot
Water, 460-3-60, Forward Curve Blades, Class II Blower, 2" Deflection
Under Supply Air Blower, Bypass VFD, 25HP High Efficiency Indoor
Blower Motor (not available on 25 Ton), Copper Tube/Aluminum Fin
Condenser Coil, Copper Tube/Aluminum Fin Evaporator Coil, 6" Rigid
95% Efficient Filters (Includes 2" Throwaway Pre-filter) MERV 14,
Factory Installed Modulating Power Exhaust with Variable Frequency
Drive, 15HP High Efficiency Exhaust Motor, Economizer, Low Leak
Seals with Dual Enthalpy Sensor, IPU Control (BACnet MS/TP
Protocol), All Doors Hinged, Stainless Steel Drain Pan
• Hot Gas Bypass
• Factory Wired External Non Fused Disconnect Switch and
Convenience Outlet (110 VAC)
Roof Curb - 14" High, Flat, Uninsulated, Partial Perimeter (Shipped
Knocked Down) Condenser Section Supported by a Separate Channel
Included
12.5 Ton, Johnson Controls Series 10 Single Packaged R-410A Air
Conditioner, 11.7 EER / 14.1 IEER, No Factory Installed Heat, 5 HP
High Static Belt Drive Blower, 460-3-60, Microchannel Condenser Coil
• Dry Bulb Economizer w/Power Exhaust and Hoods (Bottom return
only)
• Non Fused Disconnect Switch
• Powered Convenience Outlet (110 VAC / 15 Amp)
• 4" Pleated Filters (MERV 13)
• Phase Monitor
• Dirty Filter Switch
• Stainless Steel Drain Pan
• Coil Guard
• Hot Gas Bypass
• VAV Controller with VFD, Manual Bypass & SimplicityLINC (BACnet
MS/TP Protocol)
Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped
Knocked Down)
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
Series 20 (15-25 Ton)
Page: 2
ZJ - 10.4 to 12.4 EER Single Pkg. R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Tag #: RTU-Cafeteria
Model #:
J15ZJC00Q4TZZ1
System:
J15ZJC00Q4TZZ1
Cooling Performance
Total capacity
Sensible capacity
Refrigerant type
Efficiency (at ARI)
Ambient DB temp.
Entering DB temp.
Entering WB temp.
Leaving DB temp.
Leaving WB temp.
Part load efficiency
Power input (w/o blower)
Sound power
187.8 MBH
137.7 MBH
R410A
12.40 EER
95 °F
81.4 °F
66.7 °F
55.9 °F
54.5 °F
13.9 IPLV
13.08 kW
89 dB(A)
Supply Air Blower Performance
Supply air
Ext. static pressure
Blower speed
Duct location
Motor rating
Actual required BHP
Power input
Elevation
Drive type
5000 CFM
2 IWG
1131 RPM
Side
5.00 HP
4.12 HP
3.70 kW
0 ft.
BELT
Outside/Mixed Air
Use Mixed Air
Outside Air CFM
Outside Air DB temp.
Outside Air WB temp.
Outside Air RH
Return Air CFM
Return Air DB temp.
Return Air WB temp.
Return Air RH
Yes
2000 CFM
91 °F
73 °F
42.7 %
3000 CFM
75 °F
62 °F
48.1 %
Electrical Data
Power supply
Min circuit ampacity
Max over-current protection
460-3-60
49.30 Amps
50 Amps
Dimensions & Weight
Hgt
53 in.
Len
181 in.
Weight with factory installed options
Wth
92 in.
3144 lbs.
Clearances
Right
Top
36 in.
72 in.
Front
Bottom
36 in.
0 in.
Back
Left
49 in.
36 in.
15 Ton
• Series 20 units are manufactured at an ISO 9001 registered facility and each
rooftop is completely computer-run tested prior to shipment.
STANDARD FEATURES
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours
•
•
•
•
•
Salt Spray Test (ASTM B-117 Standards).
Four independent refrigerant circuits for efficient part load operation
Scroll Compressors
Through-the-Curb and Through-The-Base electrical and gas connections
Standard 2" throwaway filter
Either supply and/or return can be field converted from vertical to horizontal
configuration without cutting panels.
Full perimeter base rails with built in rigging capabilities.
Field installed 0 - 25% manual outside air damper shipped inside unit
Liquid line filter-driers
Single point power connection
•
•
•
•
Standard Unit Controller: (Simplicity® Control Board)
• An integrated low-ambient control, anti-short cycle protection, lead-lag, fan
•
on and fan off delays, low voltage protection, on-board diagnostic and fault
code display.
Safety Monitoring - Monitors the high and low-pressure switches, the
freezestats, the gas valve, if applicable, and the temperature limit switch on
gas and electric heat units. The unit control board will alarm on ignition
failures, safety lockouts and repeated limit switch trips.
WARRANTY
• One (1) -year limited warranty on the complete unit.
• Five (5) -year warranty - Compressors and electric heater elements
• Ten (10) -year warranty - Aluminized and stainless steel tubular heat
exchangers
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 20 (15-25 Ton)
Page: 3
ZJ - 10.4 to 12.4 EER Single Pkg. R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Tag #: RTU-Cafeteria
Model #:
J15ZJC00Q4TZZ1
System:
J15ZJC00Q4TZZ1
Factory Installed Options
J15ZJC00Q4TZZ1
Nominal Cooling Capacity:
J15
15 Ton
Product Category:
Z
Johnson Controls Series 20 Single Packaged R-410A Air
Conditioner
Product Identifier:
J
12.4 EER / 13.9 IPLV
Heat Type and Nominal Heat Capacity:
C00
No Factory Installed Heat
Airflow:
Q
Dry Bulb Economizer w/Power Exhaust and Hoods
(Bottom return only)
5 HP High Static Belt Drive Blower
2" Throwaway Filters
Voltage:
4
460-3-60
Installation Options:
T
Powered Convenience Outlet (110 VAC / 15 Amp)
Non Fused Disconnect Switch
Additional Options:
ZZ
Product Generation:
1
Copper Tube/Aluminum Fin Condenser Coil
Coil Guard
Dirty Filter Indicator Switch
Stainless Steel Drain Pan
Double Wall Cabinet
Hinged & Tool Free Filter, Blower, Motor and Electrical
Access Panels
VAV Controller with VFD, Manual Bypass & SimplicityLINC
(BACnet MS/TP Protocol)
Hot Gas Bypass
Field Installed Accessories
● 1RC0478 - Roof Curb - 24" High,
Flat, Uninsulated, Full Perimeter
(Shipped Knocked Down Vendor
Direct) (Required on units with ERV
size 36 & above) (135.0 lbs)
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 20 (15-25 Ton)
Page: 4
ZJ - 10.4 to 12.4 EER Single Pkg. R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Tag #: RTU-Cafeteria
Model #:
J15ZJC00Q4TZZ1
System:
J15ZJC00Q4TZZ1
Unit Dimensions Front View and Utilities Entry
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 20 (15-25 Ton)
Page: 5
ZJ - 10.4 to 12.4 EER Single Pkg. R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Tag #: RTU-Cafeteria
Model #:
J15ZJC00Q4TZZ1
System:
J15ZJC00Q4TZZ1
Rear View Unit Dimensions
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 20 (15-25 Ton)
Page: 6
ZJ - 10.4 to 12.4 EER Single Pkg. R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Tag #: RTU-Cafeteria
Model #:
J15ZJC00Q4TZZ1
System:
J15ZJC00Q4TZZ1
Center of Gravity, Unit and Accessory Weights
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 20 (15-25 Ton)
Page: 7
ZJ - 10.4 to 12.4 EER Single Pkg. R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Tag #: RTU-Cafeteria
Model #:
J15ZJC00Q4TZZ1
System:
J15ZJC00Q4TZZ1
Typical Installation
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 20 (15-25 Ton)
Page: 8
ZJ - 10.4 to 12.4 EER Single Pkg. R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Tag #: RTU-Cafeteria
Model #:
J15ZJC00Q4TZZ1
System:
J15ZJC00Q4TZZ1
Typical Control Diagram
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 20 (15-25 Ton)
Page: 9
ZJ - 10.4 to 12.4 EER Single Pkg. R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Tag #: RTU-Cafeteria
Model #:
J15ZJC00Q4TZZ1
System:
J15ZJC00Q4TZZ1
Typical Component Location
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Page: 10
Project Name:
Douglas Middle School
Model #:
Quantity: 1
System:
1RC0478
J15ZJC00Q4TZZ1
1RC0478 Roof Curb Dimensions, Duct Openings, and Cut Away
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 40 (25-40 Ton)
Page: 11
JCI Series 40 Single Pkg Units R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Model #:
Tag #: RTU-Classroom A&B
System:
V34AW24R8KCXAU
V34AW24R8KCXAU
Cooling Performance
Total capacity
Sensible capacity
Refrigerant type
Efficiency (at ARI)
Ambient DB temp.
Entering DB temp.
Entering WB temp.
Leaving DB temp.
Leaving WB temp.
Power input (w/o blower)
486.6 MBH
330.5 MBH
R410A
10.50 EER
95 °F
81 °F
68 °F
55.5 °F
55.1 °F
38.22 kW
Heating Performance
Entering DB temp.
Heating output capacity (Max)
Leaving DB temp.
Flow rate
Air temp. rise
Entering water temperature
50 °F
401.1 MBH
80.9 °F
40 GPM
30.9 °F
160 °F
Supply Air Blower Performance
Supply air
Ext. static pressure
Unit static resistance
Blower speed
Motor rating
Actual required BHP
Power input
Elevation
Drive type
12000 CFM
2 IWG
1.65 IWG
890 RPM
25 HP
16.28 HP
13.24 kW
0 ft.
BELT
Exhaust Air Blower Performance
Supply air
Ext. static pressure
Blower speed
Motor rating
Actual required BHP
Power input
Drive type
12000 CFM
1.5 IWG
1035 RPM
15 HP
8.10 HP
6.64 kW
BELT
Electrical Data
Power supply
Min circuit ampacity
Max over-current protection
460-3-60
142.00 Amps
175 Amps
Dimensions & Weight
Hgt
64 in.
Len
276 in.
Weight with factory installed options
Wth
92 in.
6490 lbs.
Clearances
Right
Top
60 in.
120 in.
Front
Bottom
60 in.
0 in.
Back
Left
60 in.
60 in.
40 Ton
• The Series 40 rooftop line is designed to provide peak performance and
value for years to come. Series 40 units are manufactured at an ISO 9001
registered facility and each rooftop is completely computer-run tested prior to
shipment.
STANDARD FEATURES
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Salt Spray Test (ASTM B-117 Standards).
Double Wall Cabinet Construction Provides Superior Cleanability and
Structural Integrity.
Each Scroll Compressor Has An Independent Refrigeration Circuit.
Low Profile Clearance at 64" Above Roof Curb
Polyurethane protective sleeves over distributor tubing
Condenser Coils Angled To Protect From Hail, Shipping, and Handling
Damage.
Front-Side Easy Access Hinged Doors for Servicability
Sloped Drain Pan Capable of Draining Over 3 Gallons per Minute. The Pan
is Easily Accessed for Cleaning.
High and low refrigerant pressure protection
Vibration Isolated Supply Fan and Motor
Single Power Point Connection
Standard 2" Throwaway Filter
Sloped unit roof with drip lip
Intertwined Evaporator Coils Provide Larger Heat Transfer at Part Load.
Features Through-the-Curb and Through-The-Base Electrical and Gas
Connections
1 ½" Insulation Between the Sheet Metal Skin Surfaces Throughout the Unit
Protects From Sweating.
Standard Mechanical Cooling From 40° F to 125° F
•
Standard Unit Controller:
• Single Button Programming and LED Display
• The Controller Communicates on the Modbus RTU Protocol.
• 365-Day Real Time Clock with Both Daily and Holiday scheduling
• 2 Occupancy and 20 Holiday Programmable Schedules
• Controller Can Communicate to a Windows Based PC Using Freenet
•
Adapter and Free Simplicity Software.
Intelligent Recovery To Bring Space Temperature Up To Occupied Settings
Quickly and Economically
WARRANTY
• One (1) Year Limited Parts-Only Warranty on the Complete Unit.
• One (1) Year Parts-Only Warranty on Compressors and Electric Heater
•
Unitary Sales Tool v1.5.2.0
Elements.
Ten (10) Year Parts-Only Warranty on Aluminized and Stainless Steel
Tubular Heat Exchangers.
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 40 (25-40 Ton)
Page: 12
JCI Series 40 Single Pkg Units R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Model #:
Tag #: RTU-Classroom A&B
System:
V34AW24R8KCXAU
V34AW24R8KCXAU
Factory Installed Options
V34AW24R8KCXAU
Johnson Controls Series 40 Single Packaged R-410A Air
Conditioner
Unit Type:
V
Product Generation:
3
Basic Unit:
4
40 Ton
Configuration:
A
Bottom Return, Bottom Supply
Heat:
W2
Hot Water Coil, 2 Rows Hot Water
Voltage:
4
460-3-60
Indoor Blower:
R
Forward Curve Blades, Class II Blower
2" Deflection Under Supply Air Blower
Bypass VFD
Indoor Motor:
8
25HP High Efficiency Indoor Blower Motor (not available
on 25 Ton)
Refrigeration:
K
Copper Tube/Aluminum Fin Condenser Coil
Copper Tube/Aluminum Fin Evaporator Coil
Hot Gas Bypass
Filters:
C
6" Rigid 95% Efficient Filters (Includes 2" Throwaway Prefilter) MERV 14
Exhaust:
X
Factory Installed Modulating Power Exhaust with Variable
Frequency Drive
15HP High Efficiency Exhaust Motor
Economizer:
A
Economizer, Low Leak Seals with Dual Enthalpy Sensor
Controls / Disconnect:
U
IPU Control (BACnet MS/TP Protocol)
Factory Wired External Non Fused Disconnect Switch and
Convenience Outlet (110 VAC)
Custom Options:
All Doors Hinged
Stainless Steel Drain Pan
Field Installed Accessories
● 1RC0455P - Roof Curb - 14" High,
Flat, Uninsulated, Partial Perimeter
(Shipped Knocked Down) Condenser
Section Supported by a Separate
Channel Included (385.0 lbs)
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 40 (25-40 Ton)
Page: 13
JCI Series 40 Single Pkg Units R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Model #:
Tag #: RTU-Classroom A&B
System:
V34AW24R8KCXAU
V34AW24R8KCXAU
V34 Clearances
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 40 (25-40 Ton)
Page: 14
JCI Series 40 Single Pkg Units R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Model #:
Tag #: RTU-Classroom A&B
System:
V34AW24R8KCXAU
V34AW24R8KCXAU
V34 Bottom Supply and Return
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 40 (25-40 Ton)
Page: 15
JCI Series 40 Single Pkg Units R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Model #:
Tag #: RTU-Classroom A&B
System:
V34AW24R8KCXAU
V34AW24R8KCXAU
V34 Overhead, Component, Side and End View
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 40 (25-40 Ton)
Page: 16
JCI Series 40 Single Pkg Units R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Model #:
Tag #: RTU-Classroom A&B
System:
V34AW24R8KCXAU
V34AW24R8KCXAU
40 Ton Unit Dimensions
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 40 (25-40 Ton)
Page: 17
JCI Series 40 Single Pkg Units R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Model #:
Tag #: RTU-Classroom A&B
System:
V34AW24R8KCXAU
V34AW24R8KCXAU
V34 Construction Features and Center of Gravity
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 40 (25-40 Ton)
Page: 18
JCI Series 40 Single Pkg Units R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Model #:
Tag #: RTU-Classroom A&B
System:
V34AW24R8KCXAU
V34AW24R8KCXAU
V34 Component Location
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Page: 19
Project Name:
Douglas Middle School
Model #:
Quantity: 1
System:
1RC0455P
V34AW24R8KCXAU
1RC0455P Partial Roof Curb Dimensions
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 10 (6.5-12.5 Ton)
Page: 20
JCI Series 10 Single Pkg. R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Tag #: RTU-Administration
Model #:
J12ZHC00Q4TZZ5
System:
J12ZHC00Q4TZZ5
Cooling Performance
Total capacity
Sensible capacity
Refrigerant type
Efficiency (at ARI)
Integrated eff. (at ARI)
Ambient DB temp.
Entering DB temp.
Entering WB temp.
Leaving DB temp.
Leaving WB temp.
Part load efficiency
Power input (w/o blower)
Sound power
147.6 MBH
100.8 MBH
R410A
11.70 EER
14.10 IEER
95 °F
79.2 °F
65.2 °F
51.7 °F
50.2 °F
14.1 IPLV
11.24 kW
84 dB(A)
Supply Air Blower Performance
Supply air
Ext. static pressure
Unit static resistance
Blower speed
Duct location
Motor rating
Actual required BHP
Power input
Elevation
Drive type
3400 CFM
1.89 IWG
0.11 IWG
1135 RPM
Side
5.00 HP
2.66 HP
2.48 kW
0 ft.
BELT
Outside/Mixed Air
Use Mixed Air
Outside Air CFM
Outside Air DB temp.
Outside Air WB temp.
Outside Air RH
Return Air CFM
Return Air DB temp.
Return Air WB temp.
Return Air RH
Yes
900 CFM
91 °F
73 °F
42.7 %
2500 CFM
75 °F
62 °F
48.1 %
Electrical Data
Power supply
Min circuit ampacity
Max over-current protection
460-3-60
45.50 Amps
50 Amps
Dimensions & Weight
Hgt
51 in.
Len
120 in.
Weight with factory installed options
Wth
59 in.
1370 lbs.
Clearances
Right
Top
12 in.
72 in.
Front
Bottom
36 in.
0 in.
Back
Left
36 in.
36 in.
12.5 Ton
• Johnson Controls Series 10 units are manufactured at an ISO 9001
registered facility and each rooftop is completely computer-run tested prior to
shipment.
STANDARD FEATURES
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours
•
•
•
•
Salt Spray Test (ASTM B-117 Standards).
Scroll Compressors
Through-the-Curb and Through-The-Base electrical and gas connections
Standard 2" throwaway filter
Either supply and/or return can be field converted from vertical to horizontal
configuration without cutting panels.
Full perimeter base rails with built in rigging capabilities.
Liquid line filter-driers
Phase Monitor
Single point power connection
Slide-out Condensate Drain Pan
Slide-out Blower/ Motor Assembly
Hinged Access Panels
Microchannel aluminum tube/aluminum fin condenser
•
•
•
•
•
•
•
•
Standard Unit Controller: (Simplicity® Control Board)
• An integrated low-ambient control, anti-short cycle protection, lead-lag, fan
•
on and fan off delays, low voltage protection, on-board diagnostic and fault
code display.
Safety Monitoring - Monitors the high and low-pressure switches, the
freezestats, the gas valve, if applicable, and the temperature limit switch on
gas and electric heat units. The unit control board will alarm on ignition
failures, safety lockouts and repeated limit switch trips.
WARRANTY
• One (1) Year Limited Warranty on other parts.
• Five (5) Year Warranty - Compressors and Electric Heater Elements.
• Ten (10) Year Warranty - Aluminized and Stainless Steel Tubular Heat
Exchangers.
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 10 (6.5-12.5 Ton)
Page: 21
JCI Series 10 Single Pkg. R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Tag #: RTU-Administration
Model #:
J12ZHC00Q4TZZ5
System:
J12ZHC00Q4TZZ5
Factory Installed Options
J12ZHC00Q4TZZ5
Nominal Cooling Capacity:
J12
12.5 Ton
Product Category:
Z
Johnson Controls Series 10 Single Packaged R-410A Air
Conditioner
Product Identifier:
H
11.7 EER / 14.1 IEER
Heat Type and Nominal Heat Capacity:
C00
No Factory Installed Heat
Airflow:
Q
5 HP High Static Belt Drive Blower
Dry Bulb Economizer w/Power Exhaust and Hoods
(Bottom return only)
Voltage:
4
460-3-60
Installation Options:
T
Non Fused Disconnect Switch
Powered Convenience Outlet (110 VAC / 15 Amp)
Additional Options:
ZZ
Product Generation:
5
4" Pleated Filters (MERV 13)
Microchannel Condenser Coil
Phase Monitor
Dirty Filter Switch
Stainless Steel Drain Pan
Coil Guard
Hot Gas Bypass
VAV Controller with VFD, Manual Bypass & SimplicityLINC
(BACnet MS/TP Protocol)
Field Installed Accessories
● 1RC0471 - Roof Curb - 14" High,
Flat, Uninsulated, Full Perimeter
(Shipped Knocked Down) (135.0 lbs)
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Series 10 (6.5-12.5 Ton)
Page: 22
JCI Series 10 Single Pkg. R-410A AC
Project Name:
Douglas Middle School
Quantity: 1
Tag #: RTU-Administration
Model #:
J12ZHC00Q4TZZ5
System:
J12ZHC00Q4TZZ5
Typical Component Location
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011
D
O
Page: 23
Project Name:
Douglas Middle School
Model #:
Quantity: 1
System:
1RC0471
J12ZHC00Q4TZZ5
1RC0471 Roof Curb Dimensions
Unitary Sales Tool v1.5.2.0
Information is subject to change without notice. Check local codes.
Printed 05/24/2011