VLT MICRO
®
New compact, powerful AC drive
for HVAC applications through 3 HP
The Ideal Drive for Limited Space
The VLT MICRO is the perfect drive for anyone needing a small adjustable frequency drive in the 1/2 to 2 HP, 208/230 V AC or
1 to 3 HP, 460 V AC range. The VLT MICRO provides a stepless, sinusoidal three-phase output to the motor. Both single and
three-phase input models are available in the 200 through 240 volt unit. All units are UL listed, and all three-phase input units
are CE marked. The single phase 200 through 240 volt input units offer CE marking as an option. All units provide three-phase
output to operate standard induction motors.
A small footprint, sophisticated control and a user friendly keypad are only some of the many features of the VLT MICRO.
To top it off, they have excellent reliability and easy operation ... all at a low price!
VLT MICRO Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Simple installation and operation.
Compact overall size saves space and installation cost.
All models are UL and C-UL listed.
All models are enclosed in a protected chassis enclosure
(IP 20)
Perfect for panel mounting.
Optional DIN rail mount available.
Optional remote keypad mounting kit available.
Easy access to all terminal connections.
Programmable digital inputs and outputs
Low noise operation.
Carrier frequency adjustable to 18 kHz for quiet operation.
Full continuous output is available for carrier frequencies
through 16 kHz.
Programmable V/Hz for optimum operation with variable
torque loads.
Overload current — 150% of rated current for 1 minute.
Automatic voltage regulation changes output voltage in
response to load. Full voltage is always available for heavy
loads, but at light loads the voltage is reduced for highest
efficiency and coolest operation.
S-curve or linear accel and decel ramp profiles.
Three step-over frequencies.
Programmable offset and gain for easy adaptation to nonstandard speed reference signals.
Automatic synchronization with motor after momentary
power loss.
Parameter lock-out prevents unauthorized changes.
Programmable DC braking.
Fault history log.
Local speed operation can be either from the control
panel’s potentiometer or the “UP” ”DOWN” keys.
208/230 V, 3ø, UL and CE
230 V, 1ø, UL
Protection Features
•
•
•
•
•
•
•
•
•
Self-testing
Overvoltage
Overcurrent
Undervoltage
Overload
Over temperature
External fault
Electronic thermal overload
Ground fault
2
460 V, 3ø, UL and CE
230 V, 1ø, UL and CE
Easy to Program, Easy to Run
The digital keypad and display module is standard on every
VLT MICRO. This module has two functions, display and
control.
decimal point to the right. When the number would require
five digits, ten percent of the value is automatically displayed
and the decimal point is not shown.
Display shows the present status of the drive. The 7-segment
LED display can show output frequency, RPM, % of output
frequency, motor current, forward or reverse rotation, or a
custom unit. The custom unit is proportional to output
frequency. The drive’s intelligent display makes the optimum
use of the four large digits on the display. When the value
displayed is less than 1000, the actual value is shown with a
The control function encompasses operating the drive directly
from the keypad and programming advanced functions to
customize the drive for the precise needs of the application.
Manual speed can be controlled by either the “UP” and
“DOWN” arrows or the familiar rotary speed potentiometer. All
of the drive’s parameters can be accessed by a simple press
of the “MODE” key.
MODE
ENTER
RUN
MODE
Pressing the “MODE” key displays the status of
the drive, including the reference frequency,
output frequency, or output current. It also
selects the programming mode.
DIGITA
L KEY
ENTER
Pressing the “ENTER” key stores parameter
values into memory.
RUN
Pressing the “RUN” key will start the drive
when local control is utilized.
RUN
MODE
STOP/RESET
Pressing the “STOP/RESET” key stops the
drive when running under local control. It also
resets the drive after a fault has been cleared.
STOP
RESET
UP/DOWN
The “UP” and “DOWN” keys have a variety of
functions. When the drive is operating in local
speed control, these keys can be used to
increase or decrease the drive's speed. In
parameter access mode, these keys are used
to scroll through the list of parameters and
choose the one that is to be edited. In
parameter editing mode, the keys are used to
select the new value of the parameter.
RUN
STOP
FWD
REV
ENTER
0
FWD
REV
RUN
STOP
RESET
VLT ® MI
CRO
50
FREQ.
STOP
PAD
100
SET
LED Indicators
The four LEDs will light to indicate the current
operating status of the drive. The STOP LED
flashes when the drive is given a run
command signal, but the speed reference is
zero.
3
Specifications
Input Voltage Range 200 to 240 V AC, 1ø and 3ø
VLT Order Number
1ø, UL
1ø, UL and CE
3ø, UL and CE
176F7300
176F7306
176F7303
176F7301
176F7307
176F7304
176F7302
176F7308
176F7305
Amps
Amps
2.5
3.7
5.0
7.5
7.0
10.5
Output
Output Current
Continuous
Intermittent
Typical Shaft Output
Continuous kVA
Maximum Motor Wire Size
HP
0.5
1.0
2.0
kVA
1.0
1.9
2.7
AWG
14
14
14
1ø, Amps
3ø, Amps
6.3
2.9
11.4
6.3
15.7
8.8
Input
Maximum Input Current
Maximum Input Wire Size
AWG
14
14
14
Maximum Input Fuse
Amps
10
20
25
Watts
34
61
94
Environment
Estimated Power Loss
at Rated Maximum Load
Enclosure
Protected Chassis (IP 20)
Weight
1ø, lbs.
3ø, lbs.
1.75
1.75
2.0
1.75
2.25
2.0
176F7312
176F7313
176F7314
Amps
Amps
3.0
4.8
4.0
6.1
5.0
8.1
HP
1.0
2.0
3.0
kVA
2.3
3.1
3.8
AWG
mm2
14
2
14
2
14
2
Maximum Input Current
Amps
4.2
5.7
7.0
Maximum Power Wire Size
AWG
mm2
14
2
14
2
14
2
Maximum Input Fuse
Amps
10
15
20
Watts
59
82
113
Input Voltage Range 380 to 480 Volt AC, 3ø
VLT Order Number
3ø, UL and CE
Output
Output Current
Continuous
Intermittent
Typical Shaft Output
Continuous kVA
Max. Motor Wire Size
Input
Environment
Estimated Power Loss
at Rated Maximum Load
Enclosure
Weight
4
Protected Chassis (IP 20)
lbs.
2.25
2.5
2.75
Technical Data
AC Line Supply
Input voltage ..................................................................................................................................................... Nominal ±10%
Input frequency ...................................................................................................................................................... 50 or 60 Hz
Undervoltage trip point .................................................................................................................................. 180 or 342 V AC
Overvoltage trip point .................................................................................................................................... 264 or 528 V AC
Maximum imbalance of supply voltage ....................................................................................... ±2% of rated supply voltage
Short circuit rating ......................................................................................................................................................... 5000 A
Efficiency ........................................................................................................................................................................... 0.95
Output
Output voltage ............................................................................................................................. 0 to 100% of supply voltage
Output frequency ................................................................................................................................................ 0.1 to 400 Hz
Rated motor voltage, 200-240 V units ............................................................................................... 200/208/220/230/240 V
Rated motor voltage, 380-480 V units ........................................................................................ 380/400/415/440/460/480 V
Rated motor frequency ............................................................................................................................................... 50/60 Hz
Switching on output without damaging the drive (the drive may trip to protect itself) ............................................. Unlimited
Adjustable acceleration time ......................................................................................................... To 600 sec. to base speed
Adjustable deceleration time ..................................................................................................... To 600 sec. from base speed
Adjustable maximum speed ..................................................................................... From minimum speed setting to 400 Hz
Adjustable minimum speed ......................................................................................... From maximum speed setting to 0 Hz
Torque Characteristics
Starting torque ................................................................................................................................................. 150% for 1 min.
Break-away torque .......................................................................................................................................... 200% for 5 sec.
Acceleration torque ......................................................................................................................................................... 100%
Overload torque ............................................................................................................................................... 150% for 1 min.
Control Card Inputs
Number of programmable analog inputs (selectable voltage or current) ............................................................................. 1
Voltage level ........................................................................................................................................................ 0 to 10 V DC
Input resistance ................................................................................................................................................. approx. 47 kΩ
Current range .......................................................................................................................................................... 4 to 20 mA
Input resistance ................................................................................................................................................. approx. 250 Ω
Resolution ............................................................................................................................................................. 10 bit + sign
Speed pot power supply ........................................................................................................ 10 V DC, maximum load 10 mA
Number of programmable digital inputs ................................................................................................................................. 6
All analog inputs are galvanically isolated from the supply voltage.
Control Card Outputs
Number of programmable analog outputs ............................................................................................................................. 1
Voltage range of analog output ........................................................................................................................... 0 to 10 V DC
Number of programmable optically isolated transistorized digital outputs ........................................................................... 1
Maximum rating of digital output .................................................................................................................... 48 V DC, 50 mA
All digital and analog outputs are galvanically isolated from the supply voltage.
Relay Outputs
Number of programmable relay outputs .................................................................................................................. 1, Form C
Max. terminal load rating ..................................................................................... 120 V AC/28 V DC, 5 A or 240 V AC, 2.5 A
Wire Lengths and Cross-Sections:
Use 75°C copper wire minimum
Maximum motor cable length ............................................................................................................................. 165 ft. (50 m)
Maximum cable cross-section for line, motor, brake and control terminals ............................................. 14 AWG (2.0 mm2)
Control Characteristics:
Output frequency range ..................................................................................................................................... 0.1 to 400 Hz
Resolution on output frequency ................................................................................................................................... ±0.1 Hz
Full torque speed range (open loop) ............................................................................................. 20:1 of rated speed range
Speed accuracy (open loop) ............................................................................................................ 1800 rpm: max. error 2%
Environment
Enclosure ....................................................................................................................................... Protected Chassis (IP 20)
Vibration test ...................................................... 1 g at a frequency less than 20 Hz, 0.6 g at a frequency from 20 to 50 Hz
Maximum relative humidity .................................................................................................. less than 90% (non-condensing)
Ambient temperature ...................................................................................................................... 14° to 122°F (-10 to 50°C)
Temperature during storage/transport ........................................................................................... -4° to 140°F (-20 to 60°C)
Maximum altitude above sea level without derate ...................................................................................... 3300 ft. (1000 m)
5
Dimensions and Mounting Requirements
460 V AC Dimensions
208/230 V AC Dimensions
Ø0.196
(5)
0.216
(5.5)
3.35
3.13 (85)
(79.5)
3.94
3.72 (100)
(94.5)
0.47
(12)
Ø0.196
(5)
0.216
(5.5)
0.39
(10)
DIGITAL KEYPAD
DIGITAL KEYPAD
RUN
5.57
(141.5)
STOP
FWD
REV
MODE
RUN
ENTER
STOP
RESET
50
0
RUN
5.94
(151)
VLT® MICRO
STOP
FWD
REV
MODE
RUN
ENTER
STOP
RESET
50
VLT® MICRO
100
FREQ. SET
0
100
FREQ. SET
1 HP/ 0.75 KW
0.216
(5.5)
230V 3PHASE
0.216
(5.5)
WARNING:
• Do not connect AC power to
output terminals (U,V,W).
• Do not inspect components
until LEDs are turned off
for at least 1 min.
WARNING:
• Do not connect AC power to
output terminals (U,V,W).
• Do not inspect components
until LEDs are turned off
for at least 1 min.
0.216
(5.5)
0.216
(5.5)
V
Air flow clearances:
Air flow clearances:
MOTOR
U
MOTOR
W B1 B2
Above and below drive: 4.75 in (120mm)
U
V
Above and below drive: 6.00 in
(150mm)
W B1 B2
Each side of drive: 2 in (50 mm)
4.72
(120)
4.45
(113)
0.47
(12)
4.86
(123.5)
CE marked 230 volt, 1ø units
have same dimensions as 460
volt units.
4.55
(115.5)
Each side of drive: 2 in (50 mm)
0.39
(10)
Remote Keypad Kit
0.14
(3.5)
1.44
(36.5)
DIGITAL KEYPAD
0.12
(3.0)
RUN
2.76
(70.0)
STOP
FWD
REV
MODE
RUN
ENTER
STOP
RESET
50
1.50
(38.0)
100
0.77
(19.5)
FREQ. SET
0.53
(13.5)
1.30
(33.0)
Part Number
6 ft. (2 m)
176F7310
15 ft. (5 m)
176F7325
1.02
(26.0)
Dimension A
1.09
(27.8)
1.04
(26.5)
0.63
(16.0)
A
1.44
(36.5)
0.55
(14.0)
1.43
(36.4)
0
0.12
(3.0)
0.65
(16.4)
6
Typical Interconnection Diagram
Electrical Connections
Wiring and Terminals
When the installation is to conform to UL requirements, the
following fuse must be installed in the input to the drive.
The power and control wire terminal blocks are located
behind the swing-out covers at the top and bottom of the
drive.
Recommended Bussman
Type JJN or JJS Input Fuses Part Number
0.5 HP 230 V AC 1Ø
JJN 10
1 HP 230 V AC 1Ø
JJN 20
2 HP 230 V AC 1Ø
JJN 25
0.5 HP 208/230 V AC 3Ø
JJN 10
1 HP 208/230 V AC 3Ø
JJN 20
2 HP 208/230 V AC 3Ø
JJN 25
1 HP 460 V AC 3Ø
JJS 10
2 HP 460 V AC 3Ø
JJS 15
3 HP 460 V AC 3Ø
JJS 20
The six digital inputs, and one analog input, digital output and
analog output are all programmable. This makes the VLT
MICRO suitable for many different applications. Typical
terminal functions are shown below.
Braking Resistor (Option)
Brake Resistor (optional)
200-240 VAC 50/60 Hz
(Select each two terminals as
input for single input models)
380-480 VAC 50/60 Hz
B1
Recommended Input Fuses
(Bussman Type KLM)
15A for 3-phase
0.5 HP 1/3Ø
VAC
input230
power
15A for 1 HP 1/3Ø 230 VAC
20A
for
2HP
1/3Ø
230
VAC
Connect to any two for 1-phase
10A for 1.0 HP/460 VAC
15A for 2.0 HP/460 VAC
20A for 3.0 HP/460 VAC
B2
R
U
S
V
T
W
AC
Motor
Digital Signal Input Terminals
Forward/Stop
Run*
MO
Reverse/Stop
Safety
Interlock*
M1
Reset
Preset*
Speed
M2
AFM
+
GND
Multi-Step 1
Reset*
M3
Multi-Step 2
Reverse*
M4
Multi-Step 3
Multi-step*
M5
RB
GND
RC
Signal Common
Frequency Setting
0~10 VDC 1k - 5k
Current Input 4-20 mA
Analog Speed Reference Power
(0 - 10 V DC, 103mA max.)
RA
Power for
speed setting
+10 V
Analog
Frequency/Current
Meter
Alarm Output Contacts
30 VDC 2A Max
250 VAC 2A Max
MO
Multi-function
Run
indication*PHC output
48V,V/250mA
Max
48
50 mA max.
10mA
(max.)
MCM
Analog Speed Reference Power
(0 - 10 V or 4 2
- 20 mA)
1
AVI
RS-485
Ground
GND
Analog/Digital Signal Common
* The operation of all control inputs and outputs is programmable. Typical terminal functions are shown.
7
Ordering Information
VLT MICRO
Model Number
Options and Accessories
0.5 HP
230 VAC 1Ø UL
176F7300
Remote Keypad Kit
1 HP
230 VAC 1Ø UL
176F7301
2 HP
230 VAC 1Ø UL
176F7302
Includes all hardware and
6 ft. cable
1 HP
230 VAC 1Ø UL/CE
176F7307
2 HP
230 VAC 1Ø UL/CE
176F7308
0.5 HP
208/230 VAC 3Ø UL/CE
176F7303
1 HP
208/230 VAC 3Ø UL/CE
176F7304
2 HP
208/230 VAC 3Ø UL/CE
176F7305
0.5 HP
208/230 VAC 1Ø UL/CE
176F7306
EMI Filters
Part Number
1 HP
460 VAC 3Ø UL/CE
176F7312
200-240 1Ø
176F7327
2 HP
460 VAC 3Ø UL/CE
176F7313
200-240 3Ø
176F7328
3 HP
460 VAC 3Ø UL/CE
176F7314
380-480 3Ø
176F7326
Includes all hardware and
15 ft. cable
DIN Rail Adaptor
Part Number
176F7310
176F7325
Part Number
DIN Rail Adaptor Bracket Kit
230 V AC
176F7311
DIN Rail Adaptor II Bracket Kit
230 V AC 1Ø CE & 460 V AC
176F7315
Warranty
Subject to the terms herein below set forth, Seller warrants the
VLT MICRO to be free from defects in material and workmanship
if properly installed and operated and maintained under normal
conditions of use and service, for 12 months from date of
shipment, not to exceed 18 months from date of manufacture.
If, within the warranty period, Seller receives from Buyer prompt
written notice of any claim of defect and if, in the Seller's sole
judgement, the Article is found to be defective in materials or
workmanship, Seller, at its option and expense, shall replace or
repair the defective Article. The Seller's obligation and Buyer's
exclusive remedy hereunder, shall be limited to such repair or
replacement. Buyer shall, at Seller's request, ship the Article to
the Seller, transportation charges prepaid.
In no event will the Seller's liability be greater in amount than the
purchase price of the Article, and Seller reserves the right to
satisfy its warranty obligation hereunder in full by reimbursing
the Buyer for all payments made to the Seller for the Article, and
the Buyer shall thereupon return the Article to the Seller.
This warranty shall not be effective if the Article has been subject
to overload, misuse, negligence or accident, nor if the Article has
been repaired or altered outside of Seller's factory or authorized
service station in any respect which, in Seller's judgment,
adversely affected its condition or operation. Products
manufactured by others and supplied by Seller as part of Seller's
Articles are not warranted by Seller, and Buyer's sole recourse
shall be under the warranty, if any, of such other manufacturer.
Fuses are warranted only when a defect or malfunction of the
Article or its components are found to be the cause of the fuse
failure.
THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER
EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT
NOT LIMITED TO ANY IMPLIED WARRANTY OF
MARKETABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, PERFORMANCE OR OTHERWISE. SELLER
SHALL NOT BE LIABLE, UNDER ANY CIRCUMSTANCES,
FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES,
INCLUDING, BUT NOT LIMITED TO LABOR COSTS OR LOST
PROFITS RESULTING FROM THE USE OF OR INABILITY TO
USE THE ARTICLES OR FROM THE ARTICLES BEING
INCORPORATED IN OR BECOMING A COMPONENT OF ANY
OTHER PRODUCT.
Catalog #200
10/99
Danfoss Graham
Division of Danfoss Inc.
8800 W. Bradley Road
P.O. Box 245041
Milwaukee, WI 53224
Phone: (414) 355-8800 Fax: (414) 355-6117
Toll Free: (800) 621-8806
E-Mail: graham@grahamdrives.com Website: www.grahamdrives.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising