Cooper-Atkins Corporation
Cooper-Atkins Corporation
HVAC/R • OEM • INDUSTRIAL
www.cooper-atkins.com
A Message from the President/CEO:
Carol P. Wallace
Since our establishment in 1885, Cooper has built a solid
reputation as a manufacturer and provider of quality time,
temperature and humidity instruments. We take extreme pride
in our service levels and in our customer relationships. These
qualities have helped our business grow for over 118 years.
In today’s rapidly changing world, innovations in technology
have brought about dramatic changes in our industry. To better
serve our valued customers, we at Cooper Instrument have
expanded our technological capabilities by purchasing Atkins
Technical, a leader in thermocouple technology, and KTG, Inc.,
a provider of problem solving software and wireless
monitoring hardware.
Our newly formed organization will be known as Cooper-Atkins
and will have the capability to meet our customers’ needs with
a wide array of measurement solutions. By exercising the
synergies within our three locations, we are committed to
pursuing the potential of all measuring system technologies
with the expertise to support them. Our products will continue
to be offered through the brand names our customers have come
to rely on. We will continue to provide exceptional customer
service and quality products. These elements along with product
innovations, will drive our company to consistently exceed our
customers’ expectations.
Our commitment to the industries we serve is captured
in our mission and vision statements:
Mission
As an innovative global partner, we deliver measuring
systems to help our customers ensure safe food and healthy
indoor environments.
Vision
To be the global leader in innovative food safety and indoor
environment solutions.
Carol P. Wallace
President/CEO
Cooper-Atkins
Table of Contents
Thermocouple/Thermistor
Temperature Instruments . . . . . . . . . . . . . . .2-3
Humidity/Temperature Instruments . . . . . . . .4-5
Thermistor Probes . . . . . . . . . . . . . . . . . . . .6-7
Thermocouple Probes . . . . . . . . . . . . . . . . . .8-9
Accessories . . . . . . . . . . . . . . . . . . . . . . . .10-11
Digital Pocket Thermometers . . . . . . . . . . . . .12
Glass Stick Pocket Thermometers . . . . . . . . . .13
Analog Pocket Thermometers . . . . . . . . . . . . .14
Industrial Stem Thermometers . . . . . . . . . . . .15
Digital Remote Panel Thermometers . . . . .16-17
Remote Vapor Tension
Panel Thermometers . . . . . . . . . . . . . . . . .18-19
Storage/Wall Thermometers . . . . . . . . . . . .20-21
Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Refrigerator/Freezer Thermometers . . . . . . . .23
Cooking/Prep Thermometers . . . . . . . . . . . . . .24
Infrared Thermometers . . . . . . . . . . . . . . . . .25
Merchandising . . . . . . . . . . . . . . . . . . . . . .26-27
Glossary of Terms . . . . . . . . . . . . . . . . . . .28-29
Featured New Products
& Product Updates
NEW Model 4005/4005MK —
Pipe Clamp Probes
UPDATED PM120 — Rectangular Digital
Remote Panel Thermometer
This popular remote panel
thermometer is now °F/°C
switchable. See page 16
for additional information.
Fast, accurate temperature
measurements of pipe diameters
up to 1-3/8" (34.9 mm). See page 6
for Model 4005 thermistor version
and page 8 for Model 4005MK Type
K thermocouple version.
NEW PM120RH — Digital Remote
Temperature/Humidity Panel Meter
NEW Model SRH122 —
Digital Pocket Psychrometer
Monitor both
temperature and
humidity simultaneously
with this compact remote
panel thermometer.
See page 16 for
additional
information.
Portable size makes this instrument easy to
carry and it is ideal for spot-checks.
See page 4 for additional
information.
NEW Model DRH122 —
Hygrometer/Thermometer Pen
NEW 4011 — Pipe Strap Probe
Compact and easy-to-use, this multi-purpose
instrument reads both temperature and
relative humidity. See page 4 for
additional information.
Easily attach this
new pipe strap
probe to pipes up
to 5" (127 mm) in
diameter. See page 6
for additional
information.
NEW GL100 —
Water-Resistant Mini Data Logger
NEW 5028 — Slim Humidity Probe
Small and easy-to-use, this mini
data logger is self powered and
records temperatures accurately at
intervals from 1 minute to 4 hours.
See page 11 for additional
information.
This humidity probe is
the perfect solution
for air ducts and small
spaces. See page 6
for additional
information.
NEW SP160 — Digital Solar Remote
Panel Thermometer
NEW DFP450W — Waterproof Digital
Pocket Thermometer
Compact size allows
for easy installation.
Solar and battery
powered eliminates
the need for any external
power supply. See page 16
for additional information.
Waterproof, field
calibrateable, drop
resistant, rugged,
Lifetime Warranty...
need we say more!
See page 12 for
additional information.
1
Thermocouple
Thermistor
Temperature Instruments
Thermistor
Superheat Calculator
Thermistor
Temperature Instruments
Model SH88A
Model SH66A
Series
This is the perfect tool for the
heating, ventilation, air-conditioning
and refrigeration (HVAC/R)
technician. The primary function
of this instrument is to measure the
temperature and pressure values of a
refrigeration system and calculate the
system’s superheat. The instrument is
capable of measuring superheat of 16
of the most common refrigerants.
Model SH88A includes:
(1) Model 4010 Surface Probe,
(1) Model 5027 Brass Pressure
Transducer, (1) T-Fitting, (1)
Adapter, and a rugged polyethylene
storage case with removable cover
For applications where
multiple temperature
measurements need to be
taken, this is the instrument
to use. Measure suction and
liquid line temperatures
simultaneously, temperatures
across condensing coils,
evaporator coils, as well as
the ambient temperature,
all at the same time!
The Constant Scan feature records the
min/max temperature from three probes
allowing the technician to monitor critical temperatures remotely while
completing other tasks.
Model SH66A includes: (1) Model 1075 General Purpose Puncture
Probe, (1) Model 2010 Air Probe, (1) Model 4011 Surface Probe
Model SH66AC includes: (1) Model 1075 General Purpose
Puncture Probe, (1) Model 2010 Air Probe, (1) Model 4011 Surface
Probe, 7-Language Instruction Booklet, and is °C prominent
• Scan mode
• 3-Zone
• Auto shut-off with override
• Min/Max memory
• Automatically calculates superheat
• Altitude and refrigerant selector
• Special T-fitting allows monitoring of
refrigerants while recharging the system
Thermistor Temperature Instruments
Model SH44A
Series
Models TM99A, TC100A
Series
The SH44A is an
economical alternative
with the durability of
Model SH66A. This
dual-zone unit allows
for accurate temperature
measurement of two
areas at once.
Model SH44A includes: (1) Model
1075 General Purpose Puncture
Probe and (1) Model 4010 Surface Probe
Model SH44AC includes: (1) Model 1075 General Purpose
Puncture Probe, (1) Model 4010 Surface Probe, 7-Language
Instruction Booklet, and is °C prominent
For those applications where only one
temperature is read at a time, this series
of single zone temperature meters is
an industry standard. Choose from the
basic Model TM99A, the UL approved
Model TM99A-UL or the rechargeable
Model TC100A.
Model TM99A includes: (1) Model
1075 General Purpose Puncture Probe and
hard carrying/storage case
Model TM99AC includes: (1)
Model 1075 General Purpose Puncture Probe, hard carrying/storage case,
7-Language Instruction Booklet, and is °C prominent
Model TM99A-UL includes: (1) Model 1075 General Purpose
Puncture Probe, hard carrying/storage case, UL approved (Class 1,
Groups C & D), and temperature code T3C
Model TC100A includes: (1) Model 1075 General Purpose Puncture
Probe, hard carrying/storage case, NiCad battery, and battery charger
•
•
•
•
Dual zone
Min/Max memory
Scan mode
Auto shut-off
• Single zone
• Min/Max memory
• Hold button
• Auto shut-off
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • www.cooper-atkins.com
2
Thermocouple
Temperature
Instruments
Model FW2000MK
Temperature Instrument Specs
When choosing a durable
thermometer with fast
response, the FW2000MK
is a wise decision. This
instrument is ergonomically
designed, NSF certified, and
is waterproof making it
ideal for harsh wet and
steam filled environments.
The FW2000MK can
withstand a drop of six feet
(1.83 meters) without
damage to the unit.
The probe cord has been
enhanced to
extend its flex
strength to over
50,000 bends.
Model FW2000MK includes: (1) Model 1410MK-FW
Quick Response Probe
•
•
•
•
MODELS
FW2000MK
Thermocouple
SH44A
SH44AC
SH66A
SH66AC
SH88A
TM99A
TD2000
TM99AC
TD2000-01 TM99A-UL
TC100A
•
Thermistor
•
•
•
•
•
•
Temperature -100° to 999°F -40° to 300°F -40° to 300°F -40° to 300°F -40° to 300°F -58° to 2000°F -40° to 300°F
Range
-73° to 537°C -40° to 150°C -40° to 150°C -40° to 150°C -40° to 150°C -50° to 1093°C -40° to 150°C
Temperature
Accuracy
±2°F/1°C
±0.3°F/0.2°C ±0.3°F/0.2°C ±0.3°F/0.2°C ±0.3°F/0.2°C ±4°F from 58° ±0.3°F/0.2°C
or ±0.5% Rdg, or ±0.5% Rdg, or ±0.5% Rdg, or ±0.5% Rdg, to 32°F, ±0.3% or ±0.5% Rdg,
whichever
whichever
whichever
whichever
+ 2°F from
whichever
is greater
is greater
is greater
is greater 32° to 2000°F is greater
Ambient Temp. 0° to 115°F 0° to 130°F 0° to 130°F 0° to 130°F 0° to 130°F 32° to 122°F 0° to 130°F
Range
-18° to 46°C -18° to 54°C -18° to 54°C -18° to 54°C -18° to 54°C 0° to 50°C -18° to 54°C
Resolution
Waterproof
Quick response
Field calibration
Auto shut-off
1°F/°C
max
max
max
max
0.1°F/°C
0.1°F/°C
0.1°F/°C
0.1°F/°C
Pressure
Range
0 to 300 psi
Pressure
Accuracy
1% psi of
full scale
Superheat
Range
0 to 200 psi
Display
max
1°F/°C
0.1°F/°C
3 digit .5"
4 digit .5"
4 digit .5"
4 digit .5"
4 digit .5"
3.5 digit .5" 4 digit .5"
12.7 mm LCD 12.7 mm LCD 12.7 mm LCD 12.7 mm LCD 12.7 mm LCD 12.7 mm LCD 12.7 mm LCD
Backlight
•
•
•
•
INDICATIONS
Models TD2000 and TD2000-01
For those tough-working environments where you need
a durable thermocouple thermometer that will withstand
punishment, this is the perfect
instrument. The TD2000 is well
suited to industrial environments
and can handle temperature
ranges of up to 2,000°F (1093°C).
For added durability, the instrument
has a protective rubber boot that
shields it from damage if dropped.
The dual input jacks allow the
operator to monitor two locations
at once. Once temperatures are
stabilized you can display the
temperature delta between the two
probes. The TD2000 is ideal for
monitoring temperature differentials
in heating and cooling equipment.
Model TD2000 includes: (2) Model 6030MK Bead
Probes, wrist strap
Model TD2000-01 includes: (2) Model 6030MK Bead
Probes and (1) 1070MK Puncture Probe, wrist strap
LO
•
•
•
•
•
HI
•
•
•
•
•
LO-P
•
•
•
•
•
°F
•
•
•
•
•
•
°C
•
•
•
•
•
•
PSI
•
Kgf/cm2
•
bar
•
1, 2 or 3
•
CL
•
•
•
SCAN
Case
Material
•
•
•
Polyethylene
Polyethylene
ABS
Plastic
Polyethylene
Case
Dimensions
6.45" x 2.25" 9.5" x 6.5"
9.5" x 6.5"
13.5" x 9.5"
x 1.5"
x 3.5"
x 3.5"
x 4.25"
163.8 x 57.2 241.3 x 165.1 241.3 x 165.1 343 x 241.3
x 38.1 mm
x 89 mm
x 89 mm
x 108 mm
7" x 3"
x 1"
177.8 x 76.2
x 25.4 mm
6" x 2.5"
x 1.56"
152.4 x 63.5
x 39.6 mm
7" x 3"
x 1"
177.8 x 76.2
x 25.4 mm
Weight
7.6 oz/215 g 1.46 lbs/662 g 1.55 lbs/703 g 3.42 lbs/1551 g 1.27 lbs/576 g 12.5 oz/354 g 1.27 lbs/576 g
Power
Battery Life
ABS
Plastic
Polyethylene
Warranty
Polyethylene
(1) 9V Alkaline (1) 9V Alkaline (1) 9V Alkaline
500 hours
90 hours
90 hours
(6) AA
(1) 9V Nicad
90 hours
90 hours
(1) 9V Alkaline (1) 9V Alkaline
200 hours
90 hours
Factory calibrated to specifications. Field calibrateable
Calibration
• Heavy-duty
• Hold button and max
• Dual input
temperature display
• Field calibration
•
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
See glossary for
indication definitions
3
Humidity/
Temperature Instruments
Model SRH77A Series
Where temperature and relative humidity readings are important, Model SRH77A
is the expert’s choice. Whether it be HVAC/R applications, storage management,
computer room monitoring or troubleshooting, the operator will find this to be an
accurate and fast service tool.
The bright blue rugged carry case makes this tool easy to find when on location
or in the back of a service truck. Features include a backlight display for dark
environments, sealed keypad which protects the instrument from spills and dust,
and a battery eliminator jack.
Model SRH77A includes: (1) Model 1075 General Purpose Puncture Probe,
(1) Model 4010 Surface Probe, (1) Model 5028 Humidity Probe
Model SRH77AC includes: (1) Model 1075 General Purpose Puncture Probe,
(1) Model 4010 Surface Probe, (1) Model 5028 Humidity Probe, 7-Language
Instruction Booklet, and is °C prominent
•
•
•
•
3-zone
Min/Max memory
Scan mode
Auto shut-off after 15 minutes of non-use or
continuous ON mode
• Temperature differential between zones 1 and 2
• %RH and wet bulb
• Switchable °F/°C
Model SRH122 – Digital Psychrometer
No more water, no more twirling, and no more charts!
Use actual wet bulb measurements with this Digital
Pocket Psychrometer. Model SRH122 gives fast,
accurate measurement of wet bulb, dew
point, temperature, and humidity
at an economical price.
Model DRH122 – Thermo-Hygrometer Pen
Measure and display environment temperatures and humidity readings
in a matter of seconds with this compact Thermo-Hygrometer
Pen. Model DRH122 is designed for simplicity and
one-handed operation. This economical instrument
is a valuable preventive maintenance and
quality assurance tool.
• Displays: wet-bulb, dew point,
temperature, and humidity
• Min/Max memory
• Data hold
• Auto shut-off after
20 minutes of non-use
• Switchable °F/°C
• Displays: temperature and humidity
• Min/Max memory
• Switchable °F/°C
Model 9349
Optional Nylon Belt Pouch
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • www.cooper-atkins.com
4
Model TRH122 and
Model TRH122M
Monitoring relative humidity is as crucial as
monitoring temperatures in many applications.
Relative humidity affects the comfort level in homes
and offices, is important in horticulture, and plays
an important part in storage, whether it be of food
or personal belongings. These light weight units
are easy to use and can be permanently mounted
to a wall.
Humidity/Temperature Instrument Specs
MODELS
Model TRH122
• Measures
temperature
and %RH
• Accurate
internal sensors
• Switchable °F/°C
SRH77A
SRH77AC
SRH122
DRH122
TRH122
TRH122M
Thermistor
•
•
•
•
•
Temperature
Range
-40° to 300°F
-40° to 150°C
-4° to 122°F
-20° to 50°C
14° to 122°F
-10° to 50°C
32° to 122°F
0° to 50°C
14° to 140°F
-10° to 60°C
Temperature
Accuracy
±.5% Rdg or
±.3°F/.2°C
whichever is
greater
±1.8°F°/1.0°C
±2°F/1.0°C
±2°F from
32 - 104°F
±4°F above
104°F
±1.8°F/1.0°C
Ambient Temp.
0° to 130°F
Range
-18° to 54°C max
-4° to 122°F
14° to 122°F
-20° to 50°C max
-10° to 50°C max
32° to 122°F
0° to 50°C max
-10° to 50°C max
Resolution
14° to 122°F
0.1°F/°C, 1% RH
0.1°F/°C, 0.1% RH
0.1°F/°C, 1% RH
0.1°F/°C, 1% RH
0.1°F/°C, 1% RH
Humidity
Range
10 to 95% RH
0 to 100% RH
20 to 90% RH
25 to 95% RH
10 to 99% RH
Humidity
Accuracy
±2% from 20
to 80% RH
±3% from 10
to 90% RH
±5% from 40
to 80% RH
±5% from 40
to 80% RH
±5% from 25
to 95% RH
±3% below 20%
and above
80% RH
±4% below 10%
and above
90% RH
±7% below 40%
and above
80% RH
±7% below 40%
and above
80% RH
±7% below 25%
and above
95% RH
Ambient
Humidity
Range
10 to 95% RH,
90%
non-condensing
0 to 100% RH
10 to 95% RH
10 to 95% RH
10 to 100% RH
Display
4 digit, .5"
12.7 mm LCD
.25" x .35"
6.5 x 9 mm LCD
.25" LCD
6.3 mm
Dual .5"
12.7 mm LCD
Dual .43"
11 mm LCD
Backlight
•
INDICATIONS
Model TRH122M
LO
•
HI
•
LO-P
•
°F
•
•
•
•
•
°C
•
•
•
•
•
1, 2 or 3
•
CL
•
SCAN
•
%RH
•
•
•
•
•
Polyethylene
Carry Case
ABS
ABS
ABS
ABS
9.5" x 6.5" x 3.5"
241.3 x 165.1
x 89 mm
6.88" x 1.5" x 0.9"
174.7 x 38.1
x 22.8 mm
5.94" x .79" x .67"
150.9 x 20
x 17 mm
7" x 3.16" x .75"
177.8 x 80.3
x 19 mm
4.35" x 2.77" x .75"
110.5 x 70.4
x 19 mm
Weight
1.9 lbs/862 g
2.5 oz/71 g
0.8 oz/23 g
3.9 oz/111 g
2.9 oz/82 g
Power
(1) 1.5V AAA
Case
Material
Case
Dimensions
•
•
•
•
Measures temperature and %RH
Accurate internal sensors
Switchable °F/°C
Min/Max memory feature
(1) 9V Alkaline
(1) 3V CR2032
(1) 1.5V LR44
(2) 1.5V AA
Battery Life
90 hours
100 hours
1 year
1 year
1 year
Calibration
Factory
Calibrated
Factory
Calibrated
Factory
Calibrated
Factory
Calibrated
Factory
Calibrated
Warranty
1 Year
1 Year
1 Year
1 Year
1 Year
See glossary
for indication
definitions
5
Thermistor Probes
For use with all Cooper thermistor instruments
Model 1013 –
Meat packing puncture probe
Model 2010 –
Air probe
.140"/3.6 mm Ø
Model 3010 –
Plastic shaft probe
with aluminum tip
Model 1014 –
17" (431.8 mm) puncture probe with heavy-duty cord
.250"/6.4 mm Ø
.16"/4.1 mm Ø
.156"/4 mm Ø
Model 4005 –
Pipe clamp probe
Model 1030 –
Screw-in probe
with 1/8" (3.2 mm)
NPT fitting
.165"/4.2 mm Ø
Model 1050 –
Blunt tip veterinary probe
Model 4011 –
Pipe strap probe
.125"/3.2 mm Ø
Model 4040 –
Fast surface
contact probe
Model 1052 –
Needle probe
.041"/1 mm Ø
Model 5005 –
Air probe
Model 1075 –
General purpose
puncture probe
.31"/7.9 mm Ø
.125"/3.2 mm Ø
.140"/3.6 mm Ø
Model 5026R –
Humidity/
Incubator probe
Model 1078 –
7.25" (184.2 mm)
puncture
probe
.140"/3.6 mm Ø
Model 2007 –
Blunt tip
waterproof probe
.14"/3.6 mm Ø
.250"/6.4 mm Ø
Model 5028 –
Slim humidity probe
Model 7010 –
Air/surface probe
with phone plug
field assembly
.16"/4.1 mm Ø
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • cooper-atkins.com
6
Thermistor Probe Specs
MODELS
1013
1014
1030
1050
1052
1075
1078
2007
Temperature
Range
-40° to 300°F
-40° to 149°C
-40° to 300°F
-40° to 149°C
-40° to 300°F
-40° to 149°C
-40° to 300°F
-40° to 149°C
-40° to 300°F
-40° to 149°C
-40° to 300°F
-40° to 149°C
-40° to 300°F
-40° to 149°C
-40° to 300°F
-40° to 149°C
Max Tip
Temp
300°F/149°C
300°F/149°C
300°F/149°C
300°F/149°C
300°F/149°C
300°F/149°C
300°F/149°C
300°F/149°C
Max Cord
Temp
200°F/93°C
200°F/93°C
400°F/204°C
200°F/93°C
200°F/93°C
200°F/93°C
200°F/93°C
400°F/204°C
Response
Time
6 seconds
100 seconds
20 seconds
6 seconds
4 seconds
6 seconds
6 seconds
18 seconds
Sensor Type
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
Shaft Length
4"/101.6 mm
17"/431.8 mm
2.5"/63.5 mm
3.4"/86.4 mm
2.9"/73.6 mm
4"/101.6 mm
7.25"/184.2 mm
4"/101.6 mm
Cord Length
Warranty
6'/1.83 m
6'/1.83 m
polyurethane uncoiled polyurethane uncoiled
1 Year
6'/1.83 m teflon
straight cord
1 Year
6'/1.83 m
6'/1.83 m
6'/1.83 m
6'/1.83 m
polyurethane uncoiled polyurethane uncoiled polyurethane uncoiled polyurethane uncoiled
1 Year
1 Year
1 Year
1 Year
1 Year
10'/3.1 m teflon
straight cord
1 Year
MODELS
2010
Temperature -40° to 200°F
Range
-40° to 93°C
3010
4005
4011
4040
5005
5026R
5028
7010
-40° to 300°F
-40° to 149°C
-20° to 300°F
-29° to 149°C
-25° to 212°F
-32° to 100°C
-40° to 300°F
-40° to 149°C
-40° to 300°F
-40° to 149°C
32° to 130°F
0° to 54°C
0° to 150°F
-18° to 66°C
-40° to 200°F
-40° to 93°C
10 to 95% RH
10 to 95% RH
Humidity
Range
Max Tip
Temp
200°F/93°C
200°F/93°C
N/A
212°F/100°C
300°F/149°C
300°F/149°C
130°F/54°C
150°F/66°C
200°F/93°C
Max Cord
Temp
200°F/93°C
200°F/93°C
220°F/105°C
200°F/93°C
200°F/93°C
200°F/93°C
176°F/80°C
200°F/93°C
200°F/93°C
Response
Time
20 seconds
15 seconds
12 seconds
15 seconds
2 minutes
6 seconds
Sensor Type
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
Shaft Length
0.5"/12.7 mm
3"/76.2 mm
N/A
N/A
3.5"/84 mm
4.25"/108 mm
6.25"/159 mm
4.9"/124.5 mm
0.5"/12.7 mm
Cord Length
12'/3.7 m
polyurethane
straight cord
6'/1.83 m
polyurethane
uncoiled
10'/3.1 m TPE
straight cord
12'/3.7 m
straight cord
6'/1.83 m
polyurethane
uncoiled
6'/1.83 m
polyurethane
uncoiled
6'/1.83 m
polyurethane
uncoiled
6'/1.83 m
coiled cord
6"/152.4 mm
polyurethane
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
Warranty
7
20 seconds
Thermocouple Probes
Compatible with all Type K Thermocouple Instruments
with miniature connectors
Model 1075MK – Puncture probe,
semi-pointed tip, high temperature
Model 4005MK –
Pipe clamp probe
.140"/3.6 mm Ø
Model 1410MK –
Quick response large needle probe
.098"/2.5 mm Ø
.062”/
1.6 mm Ø
Model 4022MK – 5.25" (133.4 mm) surface probe
.50"/12.7 mm Ø
Model 5000MK –
Air probe with high temperature wire
Model 1410MK-FW –
FW2000MK replacement probe
.125"/3.2 mm Ø
.098"/
2.5 mm Ø
.062"/
1.6 mm Ø
Model 6010MK – 48" (1.2 meters) flexible
SS oven probe
.5
12 0"/
.7
mm
Ø
Model 1420MK – Angled surface probe
Model 6030MK – 42" (1.07 meters) bead probe
Model 3110MK – 10" (254 mm) vat probe
.250"/6.4 mm Ø
Model 6050MK – Flexible teflon probe
Model 3130MK –
30" (762 mm) vat probe
(not shown)
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • cooper-atkins.com
8
Thermocouple Probe Specs
MODELS
1075MK
1410MK
1410MK-FW
1420MK
3110MK
3130MK
-100° to 900°F
-73° to 482°C
-100° to 500°F
-73° to 260°C
-100° to 500°F
-73° to 260°C
-100° to 500°F
-73° to 260°C
-100° to 900°F
-73° to 482°C
-100° to 900°F
-73° to 482°C
Max Tip
Temp
900°F/482°C
500°F/260°C
500°F/260°C
500°F/260°C
900°F/482°C
900°F/482°C
Max Cord
Temp
220°F/105°C
200°F/93°C
200°F/93°C
200°F/93°C
500°F/260°C
500°F/260°C
Response
Time
19 seconds
1 second
1 second
2 seconds
1 second
1 second
Temperature
Range
Sensor Type
Thermocouple
Thermocouple
Thermocouple
Thermocouple
Thermocouple
Thermocouple
Shaft Length
4"/101.6 mm
3.85"/97.8 mm
3"/76.2 mm
5.5"/139.8 mm
10"/254 mm
30"/762 mm
Cord Length
3'
0.9 m TPE
4'/1.2 m
polyurethane uncoiled
32"/813 mm
silicone straight cord
4'/1.2 m
polyurethane uncoiled
35"/889 mm
SS flexible hose
35"/889 mm
SS flexible hose
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
Warranty
MODELS
4005MK
4022MK
5000MK
6010MK
6030MK
6050MK
-20° to 300°F
-29° to 149°C
-100° to 1400°F
-73° to 760°C
-100° to 900°F
-73° to 482°F
-100° to 900°F
-73° to 482°F
-100° to 500°F
-73° to 260°C
-100° to 500°F
-73° to 260°C
N/A
1400°F/760°C
900°F/482°C
900°F/482°C
500°F/260°C
500°F/260°C
Max Cord
Temp
200°F/93°C
220°F/105°C
220°F/105°C
900°F/482°C
500°F/260°C
500°F/260°C
Response
Time
2 seconds
3 seconds
18 seconds
18 seconds
.5 second
1 second
Thermocouple
Thermocouple
Thermocouple
Thermocouple
Thermocouple
Thermocouple
Shaft Length
N/A
5.25"/133.4 mm
4.25"/108 mm
N/A
N/A
0.5"/12.7 mm
Cord Length
10'/3.1 m
polyurethane straight cord
3'/0.9 m
TPE straight cord
42"/1.07 m
TPE straight cord
4'/1.2 m
stainless steel overbraid
42"/1.07 m
teflon straight cord
4'/1.2 m
teflon straight cord
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
Temperature
Range
Max Tip
Temp
Sensor Type
Warranty
9
Accessories
Protective Cases
Wire Cable
Model
87-430010-1
Model 13-758600
24-AWG 2-conductor wire allows user to extend the leads on a
thermistor unit. This wire is sold by the foot.
Safely protect your
instrument with this
hard polyethylene
storage case. For use
with Models TM99A
and TC100A.
Model 13-999249
▲
Type K, 24 AWG stranded wire, with glass braid insulation.
Temperature range: -100° to 900°F/-73° to 482°C. This wire
is sold by the foot.
Model 9010
This 10'
(3.1 m)
extension
cable allows
an operator to
extend
certain leads
depending on use
and location. Can be
used with any Cooper
thermistor probe.
Model 9339
▲
Transport your thermometer safely in this
soft carry case/holster. This pouch attaches
to your belt and the Velcro flap keeps the
unit stored safely inside. For use with
Models 460, TD2000, TD2000-01, 4005
and 4005MK.
Model 9015
▲
This high quality 50'
(15.2 m) extension
cable will accurately
send temperature
readings to your
display. It is recommended
that cable lengths do not
exceed 1,000' (304.8 m)to
insure instrument accuracy. Can
be used with any Cooper thermistor probe.
Model 9348
Protect your investment with this durable
rubber boot designed specifically for the
FW2000 series. Features include a Velcro
strap for securing to a belt and the ribbed
backing lessens the shock to the unit if
dropped.
Model 9349
This compact nylon pouch featuring a sturdy
belt clip safely holds your Model SRH122.
▲
Model 9335
Replacement cable/probe for Model DTT361.
Accessories/Miscellaneous
▲
Model 9402
Model 37-56
The 1/8" (3.2 mm) vessel clip is for our
smaller diameter stem thermometers.
This clip is a great tool for use in
photo labs and laboratory applications.
Durable water-resistant nylon
construction gives extra protection
to Models 401 and 411 infrared
thermometers.
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • www.cooper-atkins.com
10
Accessories/Miscellaneous
Model 9317
Model 9315
Battery eliminator, 9 VDC 100MA
regulated. For use with Models
SH88A, SH66A and SRH77A.
Prover/Calibration Box
provides a standard to
calibrate your Cooper
Instrument thermistor based instruments
against. Learn how to adjust and calibrate your
thermometer for ensured accuracy.
Model 9313
Battery eliminator, 9 VDC 100MA regulated.
For use with Models TM99A and TC100A.
Model 7042
Add more value to your Model SH88A with this accessory kit
which includes: battery eliminator, 4010 surface
temperature probe, adapter, and T-fitting.
Model 9302
3.56" x 3" (90.4 x 76.2 mm)
mounting flange is required
when mounting Model PM120
in an opening that is larger
then the unit itself. It fills the
space and securely holds the
unit in place.
Probe Wipes
Model 9150
GL Series – Water-Resistant Mini Data Loggers
These individually packaged probe wipes clean without skin contact.
Packaged in a master carton that holds 10 boxes of 200 single use
wipes, each wipe contains 70% Isopropyl Alcohol.
• Monitors both time and temperature
• Records at specific intervals from 1 minute to 4 hours
• Mounting bracket with adhesive backing
• Stainless steel bead chain, to hang from racks or hooks
• Long-life battery
GL100 Series – Water Resistant Mini Data Loggers
Temperature Range
-13°to 185°F (-25° to 85°C)
Temperature
Accuracy
±2°F from -4° to 158°F
±1°C from -20° to 70°C
Clock Accuracy
±2 minutes per month
Overall Tag Dimension
2" x 2-5/8"/50.8 x 66.7 mm
Records
2,048
PC Requirements
Windows 95 or higher, Minimum of 10MB of free hard drive
space and CD-Rom (will not work on Macintosh computers)
Warranty
1 Year
GL100 includes:
(2) two mini data loggers,
(2) two mounts, reader
and software
Gl00-02 includes:
(2) two mini data loggers,
(2) two mounts
11
Digital Pocket
Thermometers
From laboratories to the service repairman, these fast response digital
pocket thermometers will simplify any user’s job.
Model DFP450W
®
•
•
•
•
•
•
•
Waterproof
Field calibrateable
Max temperature hold
Auto shut-off
°F/°C switchable
Lifetime warranty
NSF Certified
Model DT300
Model
DPP400W
®
•
•
•
•
•
• On/Off switch
• °F/°C switchable
Waterproof
Min/Max/Temperature hold
Auto shut-off
°F/°C switchable
NSF Certified
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • www.cooper-atkins.com
12
Model DPS300 and DPS300C
Digital Pocket
Thermometer Specs
MODELS
Model DPS300
Temperature
Range
DFP450W
DPP400W
DT300
DPS300
Series
-40° to 450°F
-40° to 232°C
-40° to 392°F
-40° to 200°C
-40° to 302°F
-40° to 150°C
DPS300:
-58° to 302°F
DPS300C:
-50° to 150°C
Accuracy
±2°F/1°C
• Swivel head - turns 30°, 60° or 90°
• DPS300 - °F only; DPS300C - °C only
±2°F/1°C from
14° to 212°F/
-10° to 100°C
±2°F/1°C from
-10° to 212°F/
-23° to 100°C
1.8°F/1°C from
0° to 160°F/
-18° to 71°C
±3°F/1.5°C
all other ranges
±4°F/2°C
all other ranges
±3.6°F/2°C
all other ranges
Display
.25"/12.7 mm LCD
.25"/12.7 mm LCD
.25"/12.7 mm LCD
.25"/12.7 mm LCD
Stem Length
4.625"/117.5 mm
2.75"/69.9 mm
4.625"/117.5 mm
5"/127 mm
0.1°F/°C
0.1°F from -40 - 199°F
0.1°F/°C
0.1°F/°C
Resolution
1°F from 200 - 392°F
0.1°C throughout
the entire range
Power
Auto Shut-Off
Weight
Glass Stick Pocket
Thermometers
Regulatory
Listings
Warranty
(1) 1.5V #392
(1) 1.5V #A76
(1) 1.5V #A76
(1) 1.5V #A76
After 10 minutes of
non-use
After 5 minutes of
non-use
N/A
N/A
0.7 oz/20 g
0.9 oz/26 g
0.7 oz/20 g
0.8 oz/23 g
NSF
NSF
N/A
N/A
Lifetime
1 Year
1 Year
1 Year
Glass Stick Pocket
Thermometer Specs
Model 1051 Series
MODELS
• Large bore
tempered-glass tube
• Non-toxic fluid
• Plastic case with
metal clip
1051-03
1051-04
0° to 220°F
-30° to 120°F
±3°F
±3°F
N/A
N/A
Stem Length
5"/127 mm
5"/127 mm
Weight
0.6 oz/17 g
0.6 oz/17 g
Regulatory
Listings
N/A
N/A
Warranty
1 Year
1 Year
Temperature
Range
Accuracy
Dial
13
Analog Pocket
Thermometers
Analog Pocket Thermometers
The analog pocket thermometer is an economical, quick and easy way to monitor temperatures with excellent repeatability.
Model CT180 / CT220 Series
Model 1246 Series
®
•
•
•
•
•
Field calibrateable
Red protective sheath includes calibration wrench
1" (25.4 mm) magnifying lens
5" (127 mm) stem length
NSF Certified
•
•
•
•
Field calibrateable
Red protective sheath
1" (25.4 mm) magnifying lens
5" (127 mm) stem length
Model 2236 Series
Model 2238 Series
•
•
•
•
•
•
•
•
Field calibrateable
Red protective sheath
2" (50.8 mm) lens
5" (127 mm) stem length
Field calibrateable
2" (50.8 mm) lens
8" (203.2 mm) stem length
Vessel clip provided
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • www.cooper-atkins.com
14
Industrial
Stem Thermometers
The 2" dials are printed with large black numerals for
ease in viewing. Offered with three temperature ranges
and various stem lengths, these thermometers are an
excellent choice for a variety of industrial applications.
Analog Pocket Thermometer Specs
MODELS
1246-01
Temperature
Range
Model 2225 Series
Accuracy
1246-02
-40° to 180°F
0° to 220°F
CT180 Series
CT220 Series
2236-02
CT180:
-40° to 180°F
CT220:
0° to 220°F
-40° to 180°F
-40° to 80°C
CT180C:
-40° to 80°C
CT220C:
-20° to 100°C
±2°F
±2°F
±4°F/2°C
±4°F/2°C
±2°F/1°C
1"/25.4 mm dia.
1"/25.4 mm dia.
1"/25.4 mm dia.
1"/25.4 mm dia.
2"/50.8 mm dia.
Stem Length
5"/127 mm
5"/127 mm
5"/127 mm
5"/127 mm
5"/127 mm
Weight
0.7 oz/20 g
0.7 oz/20 g
0.7 oz/20 g
0.7 oz/20 g
1.2 oz/34 g
NSF
NSF
N/A
N/A
N/A
1 Year
1 Year
1 Year
1 Year
1 Year
Dial
Regulatory
Listings
Warranty
MODELS
Temperature
Range
Accuracy
Dial
Model 2245 Series
2236-06
2238-02
2238-06
0° to 220°F
-10° to 100°C
-40° to 180°F
-40° to 80°C
0° to 200°F
-10° to 100°C
±2°F/1°C
±2°F/1°C
±2°F/1°C
2"/50.8 mm dia.
2"/50.8 mm dia.
2"/50.8 mm dia.
Stem Length
5"/127 mm
8"/203.2 mm
8"/203.2 mm
Weight
1.2 oz/34 g
1.25 oz/35 g
1.25 oz/35 g
Regulatory
Listings
N/A
N/A
NSF
Warranty
1 Year
1 Year
1 Year
Industrial Stem
Thermometer Specs
MODELS
Temperature
Range
Model 2255 Series
2225 Series
2245 Series
2255 Series
2225-02: 0° to 220°F
2245-02: 0° to 220°F
2255-02: 0° to 220°F
2225-03: -40° to 160°F
2245-03: -40° to 160°F
2255-03: -40° to 160°F
2225-02: ±2°F
2245-02: ±2°F
2255-02: ±2°F
2225-03: ±3°F
2245-03: ±3°F
2255-03: ±3°F
2"/50.8 mm dia.
2"/50.8 mm dia.
2"/50.8 mm dia.
4"/101.6 mm
6"/152.4 mm
9"/228.6 mm
2.7 oz/77 g
2.9 oz/82 g
3.0 oz/85 g
1 Year
1 Year
1 Year
2225-05: 200° to 1000°F
Accuracy
2225-05: ±20°F
Dial
Stem Length
Weight
Warranty
• Bimetal coil movement and glass lens
• .25" (6.4 mm) diameter stainless steel stem
• Back flange bezel, chrome plated with
(3) .150" (3.8 mm) diameter mounting holes
equally spaced on a 2.9" (73.6 mm) diameter
bolt circle
15
Digital Remote
Panel Thermometers
Digital Solar Remote Panel Thermometers
Model SP160
Model SP120
When temperature monitoring is essential and space is limited,
the SP160 is the ultimate panel thermometer. Not only does the
compact size allow the SP160 to fit in most places that other
panel thermometers cannot - it does not require any external
power sources.
This solar powered instrument is an attractive alternative in those
applications where conventional vapor tension panel thermometers
have been used. When the ambient light is not strong enough to power
the meter, the 1.5 volt battery automatically turns the unit on.
• Unit operates using ambient light
(natural, fluorescent and incandescent)
• Solar/battery powered
• Switchable °F/°C
• Solar/battery powered
• Easy-to-read LCD display
Rectangular Digital Remote Panel Thermometers
Model PM120 –
Digital Remote Temperature Panel Meter
Model PM120RH –
Digital Remote Temperature/Humidity Panel Meter
When mounting space is limited, the digital Model PM120 is an
ideal solution. This rectangular mini remote reading thermometer
is °F and °C switchable.
Now monitor both temperature and humidity at once with this new
compact remote panel meter.
• Max/Min button/
hold down to clear
• On/Off button
• Max/Min button/
hold down to clear
• Clear button
• Dry/Comfort/Wet
icon shows on the
LCD display
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • www.cooper-atkins.com
16
Front & Back
Flange Digital Remote
Panel Thermometers
Model DM120 Series /
DM450 Series
Digital Remote Panel Meter Specs
MODELS
When a cabinet and / or enclosure requires fast and
accurate temperature readings, the DM120 and DM450
series are the best choice. With the removable lens,
battery replacement is easy.
SP160
Thermistor
Temperature
Range
Humidity
Range
Temperature
Accuracy
Model DM120
SP120
PM120
•
•
•
-58° to 158°F
-58° to 158°F
-50° to 70°C
-40° to 122°F
-40° to 50°C
±2°F from -4
to 31.9°F
±1°F from 32
to 122°F
±3.6°F below -4
and above 122°F
Lux Rating
Lead Length
Mounting
Indications
Model DM450
DM450
Series
•
•
•
-12° to 140°F DM120/DM120S: DM450/DM450S:
-24.4° to 60°C
-40° to 120°F
-40° to 450°F
DM120CS:
-40° to 50°C
±3°F
±1.5°C
±2°F from -40
to 122°F
±1°C from -12
to 50°C
±2°F from -12
to 140°F
±2°F/±1°C from ±2% of reading
-4°F/-20°C to
77°F/25°C
±1°C from -24.4 ±4°F/±2°C below
to 60°C
-4°F/-20°C and
above 77°F/25°C
±5% 30 to
75%, with
temperature from
32 to 122°F
0 to 50°C
Ambient Temp. 0° to 120°F
Range
max
Model DM120S
DM120
Series
10 to 99% RH
Humidity
Accuracy
Resolution
Response
Time
Display
PMRH120
0° to 120°F
-18° to 50°C
max
0° to 120°F
-18° to 50°C
max
0° to 120°F
-18° to 50°C
max
Weight
Power
Warranty
17
0° to 150°F
max
0.1°F
0.1°F/°C
0.1°F/°C
0.1°F/°C
0.1°F/°C
0.1°F
10 seconds
10 seconds
30 seconds
30 seconds
10 seconds
10 seconds
1.825" x .625"
46.4 x
15.9 mm LCD
1.825" x .625"
46.4 x
15.9 mm LCD
1.3" x .5"
33 x 12.7 mm
LCD
1.3" x .5"
33 x 12.7 mm
LCD
1.4" x .5" LCD 1.825" x .625"
35.6 x 12.7 mm
46.4 x
LCD
15.9 mm LCD
Above 100
Above 100
N/A
N/A
N/A
N/A
4'/1.2 m
10'/3.1 m
39"/1 m
39"/1 m
39"/1 m
39"/1 m
Hangs
Hangs
N/A
N/A
Optional
Optional
DM120/DM120C:
mounting flange mounting flange
front flange
(Model 9302)
(Model 9302)
DM120S/
DM120CS:
Back flange,
surface mount
N/A
Lens
Case Material
Case
Dimensions
0° to 150°F
-18° to 65°C
max
DM450:
front flange
DM450S:
Back flange,
surface mount
Flashing HHH/HI:
Shorted probe or
above max. temp.
Flashing LLL/LO:
Open probe or
below minimum
temperature
Flashing HHH/HI:
Shorted probe or
above max. temp.
Flashing LLL/LO:
Open probe or
below minimum
temperature
2"/50.8 mm dia.
polycarbonate
2"/50.8 mm dia.
polycarbonate
Polycarbonate
Polycarbonate
Stainless steel
Stainless steel
4.5" x 1.125"
x .625"
2.77" x 2.68"
x .68"
2.7" x 1.4"
x 1.1"
2.7" x 1.4"
x 1.1"
DM120 Series:
2.97" x 1.08"
75.4 x 27.4 mm
DM450:
2.97" x 1.08"
75.4 x 27.4 mm
114.3 x 28.6
x 15.9 mm
70.4 x 68
x 17.3 mm
68.6 x 35.6
x 28 mm
68.6 x 35.6
x 28 mm
DM120S Series:
3.47" x 1.1"
88.1 x 28 mm
DM450S:
3.47" x 1.1"
88.1 x 28 mm
3.1 oz
88 g
3 oz
85 g
3.3 oz
94 g
3.3 oz
94 g
DM120/DM120C:
3.8 oz/108 g
DM450:
4.4 oz/125 g
DM120S/DM120CS:
4.6 oz/130 g
DM450S:
5.2 oz/147 g
Solar /
(1) 1.5V AAA
Solar /
(1) 1.5V A76
(1) AA
(1) AA
(1) 1.5V #393
(1) 1.5V #393
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
Remote Vapor Tension
Panel Thermometers
Remote vapor tension panel thermometers are used in many HVAC/R applications. Offering various temperature ranges these are the perfect
choice for use in walk-in refrigerators, tanks, refrigerated display cases, holding cabinets, dairy cases, freezers, floral displays and much more.
•
•
•
•
•
•
•
Recalibrateable
Dual scale dial
48" (1.2 m) capillary (except where noted)
Nickel/Tin plated bulb and capillary
Polycarbonate lens/bezel
Stainless steel cases
Bright buffed flange (6142, 6812 and 7112 series)
Model 7112 Series
Model
6142 Series
Model 7612-06
Models 8122-01 and 8822-01
Model 6642 Series
•
•
•
•
•
•
Recalibrateable
Dual scale dial
48" (1.2 m) capillary
Nickel/Tin plated bulb and capillary
Polycarbonate lens/bezel
Black painted cases
Model 8122-01
Model 6742-19
Model 8822-01
Model 6812 Series
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • www.cooper-atkins.com
18
Remote Vapor Tension Panel Thermometer Specs
MODELS
Temperature
Range
Accuracy
6142-06
6142-13
6142-20
6142-58
6642-06
6642-12
6742-19
6812-01
40° to 240°F
10° to 115°C
-40 to 120°F
-40 to 50°C
-40° to 60°F
-40° to 15°C
-40° to 60°F
-40° to 15°C
-40° to 60°F
-40° to 15°C
40° to 240°F
10° to 115°C
-40° to 60°F
-40° to 15°C
-40° to 60°F
-40° to 15°C
±5°F @ 110°F
±3°F @ 200°F
±2°F @ 40°F
±4°F @ 10°F
±5°F @ 110°F
±2°F from
10° to 40°F
±2°F from
10° to 40°F
±2°F from
10° to 40°F
±5°F @ 110°F
±3°F @200°F
±2°F from
10° to 40°F
±2°F from
10° to 40°F
±3°F below 10°F
and above 40°F
±3°F below 10°F
and above 40°F
±3°F below 10°F
and above 40°F
±2.5°C @ 43°C
±1.5°C @ 93°C
±3°F below 10°F
and above 40°F
±3°F below 10°F
and above 40°F
±1°C from
-12° to 4°C
±1°C from
-12° to 4°C
±1°C from
-12° to 4°C
±1°C from
-12° to 4°C
±1°C from
-12° to 4°C
±2.5°C @ 43°C
±1.5°C @ 93°C
±1°C @ 4°C
±2°C @ -12°C
±2.5°C @ 43°C
±1.5°C below -12°C ±1.5°C below -12°C ±1.5°C below -12°C
and above 4°C
and above 4°C
and above 4°C
Dial
±1.5°C below -12°C ±1.5°C below -12°C
and above 4°C
and above 4°C
2"/50.8 mm dia.
2"/50.8 mm dia.
2"/50.8 mm dia.
2"/50.8 mm dia.
2"/50.8 mm dia.
2"/50.8 mm dia.
2"/50.8 mm dia.
2"/50.8 mm dia.
Capillary
Length
48"
1.2 m
48"
1.2 m
48"
1.2 m
240"
6.1 m
48"
1.2 m
48"
1.2 m
48"
1.2 m
48"
1.2 m
Flange
Front
Front
Front
Front
Strap hanger
no flange
Strap hanger
no flange
U bracket
no flange
Back
Connection
Back
Back
Back
Back
Bottom
Bottom
Back
Back
Mounting
Flush
Flush
Flush
Flush
N/A
N/A
N/A
Surface
5.2 oz/147 g
5.2 oz/147 g
4.7 oz/133 g
6.8 oz/193 g
4.6 oz/130 g
5.1 oz/145 g
5.6 oz/159 g
5.7 oz/162 g
NSF
NSF
NSF
N/A
N/A
N/A
NSF
NSF
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
Weight
Regulatory
Listings
Warranty
MODELS
6812-02
6812-03
7112-01
7112-02
7112-05
7612-06
8122-01
8822-01
Temperature
Range
-40° to 120°F
-40° to 50°C
40° to 240°F
10° to 115°C
-40° to 60°F
-40° to 15°C
-40° to 120°F
-40° to 50°C
40° to 240°F
10° to 115°C
-40° to 60°F
-40° to 15°C
-40° to 60°F
-40° to 15°C
-40° to 60°F
-40° to 15°C
Accuracy
±2°F @ 40°F
±4°F @10°F
±5°F @ 110°F
±2°F @ 40°F
±4°F @10°F
±5°F @ 110°F
±2°F @ 40°F
±4°F @10°F
±5°F @ 110°F
±2°F @ 40°F
±4°F @10°F
±5°F @ 110°F
±2°F @ 40°F
±4°F @10°F
±5°F @ 110°F
±2°F @ 40°F
±4°F @10°F
±5°F @ 110°F
±2°F @ 40°F
±4°F @10°F
±5°F @ 110°F
±2°F @ 40°F
±4°F @10°F
±5°F @ 110°F
±1°C @ 4°C
±2°C @ -12°C
±2.5°C @ 43°C
±1°C @ 4°C
±2°C @ -12°C
±2.5°C @ 43°C
±1°C @ 4°C
±2°C @ -12°C
±2.5°C @ 43°C
±1°C @ 4°C
±2°C @ -12°C
±2.5°C @ 43°C
±1°C @ 4°C
±2°C @ -12°C
±2.5°C @ 43°C
±1°C @ 4°C
±2°C @ -12°C
±2.5°C @ 43°C
±1°C @ 4°C
±2°C @ -12°C
±2.5°C @ 43°C
±1°C @ 4°C
±2°C @ -12°C
±2.5°C @ 43°C
2"/50.8 mm dia.
2"/50.8 mm dia.
2.5"/63.5 mm dia.
2.5"/63.5 mm dia.
2.5"/63.5 mm dia.
2.5"/63.5 mm dia.
3.5"/89 mm dia.
3.5"/89 mm dia.
Capillary
Length
48"
1.2 m
48"
1.2 m
48"
1.2 m
48"
1.2 m
48"
1.2 m
48"
1.2 m
48"
1.2 m
48"
1.2 m
Flange
Back
Back
Front
Front
Front
Strap Hanger
No Flange
Front
Back
Connection
Back
Back
Back
Back
Back
Bottom
Back
Back
Dial
Mounting
Weight
Regulatory
Listings
Warranty
Surface
Surface
Flush
Flush
Flush
N/A
Flush
Surface
6.2 oz/176 g
6.2 oz/176 g
5.3 oz/150 g
5.8 oz/164 g
5.8 oz/164 g
5.6 oz/159 g
9.0 oz/255 g
9.0 oz/255 g
N/A
N/A
NSF
N/A
N/A
N/A
N/A
N/A
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
1 Year
19
Storage/Wall
Thermometers
Storage Thermometers
Model 212 Series
Model 255 Series
Brightly colored, oversized wall thermometers allow easy monitoring
of temperatures in critical food-related locations.
Compact version of the 212 series.
255-12 - Freezer
Thermometer
212-146 - Cooler
Thermometer
255-13 - Cooler
Thermometer
• HACCP reference color zoned dial
• Bimetal coil movement
• Large black pointer makes viewing easy
212-147 - Freezer
Thermometer
• HACCP reference color zoned dial
• Bimetal coil movement
• Large black pointer makes viewing easy
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • www.cooper-atkins.com
20
Indoor/Outdoor
Storage/Wall
Thermometers
Model 264
Storage/Wall Thermometer Specs
MODELS
212
Series
• Non-toxic spirit-filled
glass tube
• Brown polystyrene back
• White reverse printing
• Measures 7.7" x 2"
(195.6 x 50.8 mm)
255
Series
Temperature 212-146 Cooler
255-12 Freezer
Range
Therm: 10° to 80°F Therm: -10° to 80°F
264
268
IO158
Series
-40° to 120°F
-40° to 50°C
-40° to 120°F
-40° to 50°C
IO158:
-58° to 158°F
212-147 Freezer
255-13 Cooler
Therm: -10° to 80°F Therm: 10° to 80°F
IO158C:
-50° to 70°C
Accuracy
±2°F
±2°F
Dial/Lens
12.5"/317.5 mm dia
6"/152.4 mm dia
N/A
N/A
N/A
N/A
N/A
N/A
N/A
10'/3.048 m
Weight
21 oz/595 g
3.1 oz/88 g
1.7 oz/48 g
1.9 oz/54 g
5.5 oz/156 g
Power
N/A
N/A
N/A
N/A
(1) 1.5V AAA
1 Year
1 Year
1 Year
1 Year
1 Year
Sensor Length
Warranty
±2°F
±1°C
±2°F
±1°C
±2°F/1°C
or 2% of reading
Model 268
Model IO158 Series (IO158 °F only;
IO158C °C only)
• Non-toxic spirit-filled
glass tube
• Clear polystyrene back
• Black printing
• Two suction cups
• Measures 7.7" x 2"
(195.6 x 50.8 mm)
•
•
•
•
21
Hard-wired sensor
Min/Max memory
Thermistor sensor
Large 2.5" x 3" (63.5 x 76.2 mm) LCD
Timers
Model FT24
Model TCS24
The FT24 timer has both a visual and audio alarm.
The audio alarm has a volume control.
The FT24 automatically counts upwards once the time
set has elapsed, letting you know how
long it has been since the timer went
off. A one-touch start/stop button
is conveniently located on the top
of the unit.
The TCS24 is a multi-function unit with clock, timer, and stopwatch all
in one. This pocket sized timer is light enough to carry or clip on your
shirt or coat pocket without being cumbersome. This unit can be
mounted to a metal
surface via its magnetic
back or placed on a
counter top with the
fold out easel stand.
•
•
•
•
•
•
•
•
•
•
Volume controlled alarm
Oversized LCD
Red light flashes when alarm sounds
Splash-proof keypad
Built-in memory for repeat cycle timing
Measures 7" H x 6" W x 4" D (177.8 x 152.4 x 101.6 mm)
Clock/timer/stopwatch
Counts up or down in 1-second intervals
24-hour capability
Flip out stand and magnetic back
Model TS100
Model MT60
This popular lightweight timer/stopwatch
features an 18" (457 mm) soft nylon
neck cord. The TS100 was designed
with a simple 3-button function:
minutes, seconds, and start/stop.
For repetitive timing, the recall
feature automatically brings the
counter back to a previously
set time.
Simply turn the dial to the desired setting and this timer accurately
counts down.
•
•
•
•
Timer/Stopwatch
18" (457 mm) nylon neck cord
Recall feature, returns to previously set time
99 minute, 59 second counter/timer
• Easy to read numerals
• Spring wound, with sturdy molded case
• Unit will lay flat, stand or can be hung
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • www.cooper-atkins.com
22
Model 25HP –
Dial Thermometer
Timer Specs
MODELS
®
FT24
TCS24
TS100
MT60
Display
2.25" x .812"
57 x 20.6 mm
1.5625" x .4375"
39.7 x 11.1 mm
.375" x .812"
9.5 x 20.6 mm
N/A
Weight
1.175 lbs/533 g
1.9 oz/54 g
0.9 oz/26 g
3.2 oz/91 g
Power
(4) C
(1) 1.5V AAA
(1) 1.5V #A76
N/A
Warranty
1 Year
1 Year
1 Year
1 Year
Refrigerator/Freezer
Thermometer Specs
• Zoned with specific applications
and HACCP guidelines
• Sturdy stainless steel construction
• Includes dry storage range
• Hangs or stands
• NSF Certified
MODELS
Temperature
Range
Accuracy
Model 335 – Horizontal Tube Thermometer
•
•
•
•
25HP
335 Series
330
535
-20° to 80°F
-30 to 30°C
Model 335: -40° to 80°F
Model 335C: -40° to 25°C
-40° to 120°F
-40° to 50°C
-20° to 120°F
-30° to 50°C
±2°F/1°C
±2°F/1°C
±2°F/1°C
±5°F
Dial
2"/50.8 mm
diameter
5" w x 1" h
127 w x 25.4 h mm
2.75" x .625"
69.9 x 15.9 mm
2"/50.8 mm
diameter
Weight
1.5 oz/43 g
1.1 oz/31 g
0.25 oz/7 g
0.3 oz/8 g
Regulatory
Listings
NSF
N/A
NSF
N/A
Warranty
1 Year
1 Year
1 Year
1 Year
Aluminum casing
Magnifying lens
Hangs, stands, or permanently mounts
Non-toxic, spirit-filled glass tube
Model 535 – Dial Thermometer
Model 330 – Thermometer
• Lightweight design
• Durable plastic casing
• Non-toxic, spirit-filled
glass tube
• NSF Certified
®
• Magnetic back
• Self adhesive tabs for permanent mounting
23
See glossary for indication definitions
Refrigerator/
Freezer Thermometers
Cooking/Prep
Thermometers
Model DTT361 –
Digital Thermometer/Timer/Clock
Model 24HP – Oven Dial Thermometer
®
• HACCP guidelines
• Hangs or stands
• Sturdy stainless
steel construction
• NSF Certified
Model 26HP – Hot Holding Dial Thermometer
®
•
•
•
•
• Color zoned dial with
HACCP guidelines
• Hangs or stands
• Sturdy stainless
steel construction
• NSF Certified
Heat resistant stainless steel probe
Wall mount bracket and magnet supplied
Easy to read LCD
Max temperature setting w/alarm
Model QC450 –
Frozen Food Thermometer
Model 323 – Meat Thermometer
• Sensor and display are
integrated in the
stainless steel probe
for easy one-handed
operation
• Waterproof enclosure
allows for accurate use
in wet environments
• Instant read display
• Automatic shut-off after
50 minutes of non-use
®
•
•
•
•
Color zoned dial with HACCP guidelines
Sturdy stainless steel construction
Pointer for accurate measurements
NSF Certified
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • www.cooper-atkins.com
24
Infrared
Thermometers
Cooking/Prep Thermometer Specs
Non-contact infrared thermometers measure surface
temperatures fast and easily. Suitable for use in
HVAC/R, industrial, food
processing, automotive
and foodservice
applications.
MODELS
Temperature
Range
Temperature
Accuracy
24HP
26HP
323
DTT361
QC450
200° to 600° F
100° to 300°C
100° to 175°F
38° to 80°C
130° to 190°F
54° to 88°C
32° to 392°F
0° to 200°C
-40° to 450°F
±25°F/±12°C
±3°F/±1.5°C
±2°F/±1°C
±4°F/±2°C
±2°F/±1°C from
-4°/-20° to 160°F/71°C
±4°F/±2°C over
remaining range
Model 411 –
• Point and shoot with
instant results
• LCD display with
backlight
• Maximum temperature
display
• FDA Class II laser may
be turned on or off
• 8-point circular laser
• °F/°C switchable
• 7-second display hold
Dial/Display
2"/50.8 mm
diameter
2"/50.8 mm
diameter
Resolution
Probe Length
Weight
Power
Regulatory
Listings
Warranty
N/A
N/A
N/A
1°F/°C
0.1°F
N/A
N/A
6"/152.4 mm
3'/914.4 mm probe wire
3.875"/98.43 mm
1.5 oz/43 g
1.5 oz/43 g
2.5 oz/71 g
4.5 oz/128 g
3.3 oz/94 g
N/A
N/A
N/A
(1) 1.5V AAA
(1) 1.5V AAA
NSF
NSF
NSF
N/A
N/A
1 Year
1 Year
1 Year
1 Year
1 Year
2.5"/63.5 mm
diameter
1.875" x 1.375" LCD
47.6 x 34.9 mm
.75" x .375" LCD
19 x 9.5 mm
Infrared Thermometer Specs
MODELS
411
460
4400MK
Temperature
Range
Model 401
-32° to 400°F/-25° to 750°C
Model 411
-32° to 510°F/-25° to 950°C
0° to 500°
-18° to 260°C
0° to 500°
-18° to 260°C
Accuracy
1% or ±2°F/±1°C, whichever
is greater above 73°F/23°C,
±3°F /±2°C @ 0° to 73°F/
-18° to 23°C, ±4°F/±2.5°C
@ -15° to 0°F/-26°to -18°C,
±5°F/±3°C @ -25° to -15°F/
-32° to 26°C
±2% or ±3°F/±2°C at 77°F/
25°C whichever is greater,
30°F/-1°C to 77°F/25°C
±5°F/±3°C,
0°F/-18°C to 30°F/1°C
±7°F/±4°C
±2% of reading or ±3°F/±2°C,
whichever is greater at
81°F/27°C ambient operating
temperature
≤±0.5% or ≤±2°F/±1°C,
whichever is greater
±2% of reading, or ±3°F/±2°C
whichever is greater
±1% of reading, or ±2°F/±1°C
whichever is greater
500mSec (95% of reading)
500mSec (95% of reading)
1 Sec (95% of reading)
8 to 14 µm
7 to 18 µm
8 to 14 µm
Pyroelectric detector
32° to 120°F
0° to 50°C
32° to 120°F
0° to 50°C
32° to 150°F
0° to 65°C
Model 460 –
• Point and shoot with
instant results
• Time saver: fast,
accurate temperature
measurement
• Safe, non-contact
surface thermometer
• FDA Class II laser pointer
• °F/°C switchable
• 7-second temperature hold
Resolution
Repeatability
Response
Time
Spectral
Response
Ambient
Operating
Range
Laser Max
Model 4400MK – Thermocouple Probe
0.5°F/0.2°C
Laser turns off above 104°F/
40°C ambient temperature
Relative
10 to 95% RH noncondensing,
10 to 95% RH noncondensing, 10 to 95% RH noncondensing,
Humidity
at 86° to 122°F/30° to 50°C
at 86° to 122°F/30° to 50°C
at up to 86°F/30°C
Storage
-13° to 158°F
-4° to 150°F
-13° to 158°F
Temperature
-20° to 60°C without battery
-20° to 65°C without battery
-25° to 70°C
Power
(1) 9V Alkaline or NiCad battery (1) 9V Alkaline or NiCad battery
(1) 9V Alkaline
Battery Life 10 hours with laser and backlight ON Non-laser models:100 hrs
50 hours at 73°F/23°C
Distance
to Spot (D:S)
• Ergonomic design
• Sturdy construction
Emissivity
Weight
Dimensions
Warranty
25
40 hours with laser and backlight OFF
Laser Models: 12 hrs
Model 401, 12:1
Model 411, 12:1
(90% encircled energy at
focal point)
6:1
4:1
Preset at 0.95
Preset at 0.95
Preset at 0.95
11 oz/312 g
8 oz/227 g
6.4 oz/182 g
8" x 6" x 2"
203 x 152 x 51 mm
7.25" x 1.75" x 1.5"
184 x 45 x 38 mm
7.1" x 1.2" x 2"
180 x 31 x 51 mm
1 Year
1 Year
1 Year
Merchandising
Floor Display: Model LFD-11-7 includes:
Quantity
Model #
Description
2 each
Model SRH77A-E
Multi-Zone Humidity/Temperature Instrument
2 each
Model SH66A-E
Multi-Zone Temperature Instrument
3 each
Model 4005
Thermistor Pipe Clamp Probe
3 each
Model TD2000
Dual Zone Thermocouple Temperature Instrument
3 each
Model 4005MK
Thermocouple Pipe Clamp Probe
4 each
Model 1075
Thermistor General Purpose Probe
4 each
Model 2010
Thermistor Air Probe
4 each
Model 4010
Thermistor Surface Probe
4 each
Model 5026R
Humidity Probe
Cooper’s new floor displays and counter packs offer instore merchandising materials that will create excitement
and generate impulse sales. These colorful displays and
other merchandising materials available will help draw
attention to those
Cooper items
needed by the
contractor.
Floor Display: Model LFD-12-7 includes:
Quantity
Model #
Description
2 each
Model SRH77A-E
Multi-Zone Humidity/Temperature Instrument
3 each
Model 4005
Thermistor Pipe Clamp Probe
3 each
Model TD2000
Dual Zone Thermocouple Temperature Instrument
3 each
Model 4005MK
Thermocouple Pipe Clamp Probe
12 each
Model DRH122
Temperature/Humidity Pen (6 fit in display at one time)
4 each
Model SRH122
Digital Pocket Psychrometer
6 each
Model 1075
Thermistor General Purpose Probe
12 each
DFP450W
Waterproof Digital Pocket Thermometer
(6 fit in display at one time)
50 each
8-panel brochures w/literature holder
Floor Display: Model LFD-13-7 includes:
Quantity
Model #
Description
2 each
Model SRH77A-E
Multi-Zone Humidity/Temperature Instrument
2 each
Model SH66A-E
Multi-Zone Temperature Instrument
4 each
Model SRH122
Digital Pocket Psychrometer
12 each
Model DFP450W
Waterproof Digital Pocket Thermometer
(6 fit in display at one time)
4 each
Model 1075
Thermistor General Purpose Probe
4 each
Model 2010
Thermistor Air Probe
4 each
Model 4010
Thermistor Surface Probe
4 each
Model 5026R
Humidity Probe
Counter Day In A Box
• Place an order for one floor display (Models LFD-11-7, LFD-12-7, LFD-13-7 shown above)
• Order to include purchased date, purchase order number, floor display part number,
date of counter day, branch manager name, and phone number
You Receive FREE
6 each
Golf shirts (sizes must be specified on order form)
6 each
Tee shirts (sizes must be specified on order form)
6 each
Baseball caps
1 each
Counter mat
50 each
8-panel brochures with counter holder
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • cooper-atkins.com
26
Pipe Clamp Probe Display Giveaway
• Place an order for 10 each Model 4005 or Model 4005MK Pipe
Clamp Probes (can be combined)
Receive FREE
• Pipe clamp probe
demo display with 50
each 8-panel brochures
(display can hang on
slatwall or stand on
the counter)
Pegboard/Slatwall Overlay
w/Cooper Header
24" x 48" (.6 x 1.2 m) wall overlay with perforated holes to
align with peg board (can also be used on slatwall). 12pt C1S
white board with 4/color full bleed screenprinted header.
Contact your local representative for availability
Other promotional materials
• Counter mats
• 8-panel brochures with counter holder
Contact your local representative for availability
CT Series Counter Prepacks
Quantity
Model #
Description
12 per display
Model CT180-0-6
Analog Pocket Thermometer
12 per display
Model CT180-C-6
Analog Pocket Thermometer
12 per display
Model CT220-0-6
Analog Pocket Thermometer
12 per display
Model CT220-C-6
Analog Pocket Thermometer
27
Glossary of Terms
Cold Junction: The point at which thermocouple wires are joined inside
the meter.
°C: Celsius (or centigrade) relationship between Centigrade and Fahrenheit
can be found by multiplying Celsius degrees by 1.8 and then adding 32. For
example 20°C is equal to 20 x 1.8 +32 = 68°F.
Comfort Factors: Conditions other than indoor air contaminants that cause
stress, comfort, and/or health problems (e.g., humidity extremes, drafts, lack
of air circulation, noise, and overcrowding).
°F: Fahrenheit
°F = 1.8 x °C +32
inversely
°C = (°F -32) / 1.8
Compressor: The main component of an air conditioner or heat pump
system. The compressor creates pressure to maintain the flow of refrigerant.
ABS: Acrylonitrile-Butadiene-Styrene - plastic known for its toughness, impact
strength, dimensional stability, lightweight, and surface appearance. Also used in
telephones, appliances, and automobile interiors.
Condenser Coil: The coil that is located after the compressor in an air
conditioning or refrigeration system. This coil is used to remove heat from
a refrigerant in its compressed gaseous state.
ACCA: Air Conditioning Contractor of America, a national trade association
which represents heating, ventilation, air conditioning, and refrigeration
contractors.
Condensation: Water that is removed from air as it is being cooled.
Conditioned Air: Air that has been heated, cooled, humidified, or
dehumidified to maintain an interior space within the “comfort zone”.
(Can be referred to as “tempered air”.)
Accuracy: Closeness of a reading or indication of a measurement device to
the actual value of the quantity being measured.
Control Point: Temperature at which a system is to be maintained.
ARI: Air Conditioning and Refrigeration Institute. ARI standards establish
rating criteria and procedures for measuring and certifying comfort product
performance.
Cooling Load: The rate of energy removal from a given space or material.
ASHRAE: American Society of Heating, Refrigeration, and Air-Conditioning
Engineers.
Cooling Tower: A device which cools water by evaporating a portion of it in
the air. Water is cooled to the wet bulb temperature of the air.
ASTM: American Society for Testing and Materials.
D:S (Distance to Spot Ratio): Optical resolution expressed as a ratio of the
distance to the resolution spot divided by the diameter of the spot.
Cooling Coil: A heat transfer device which absorbs heat.
Acceptable Air Quality: Air in which there are no known contaminants
at harmful concentrations and with which a substantial majority (usually 80
percent) of the people exposed do not express dissatisfaction (ASHRAE
1989-62).
Data/Temperature Hold: The ability to freeze the display on any given
measurement. Useful in applications where the instrument is not easily
read while a measurement is being made.
Air Conditioning: The process of treating air to meet the requirements of a
conditioned space by controlling its temperature, humidity, cleanliness, and
distribution (ASHRAE 1989-62).
Delta: Represents the difference between two temperatures: i.e.,
higher temperature minus lower temperature. Delta is the difference.
Ambient Air: The air surrounding an object
Diffusers and Grilles: Components of the ventilation system that distribute
and diffuse air to promote air circulation in the occupied space. Diffusers
supply air and grilles return air.
Ambient: The conditions surrounding the instrument (temperature,
humidity, etc.)
Display Indications:
bar
Pressure in bars
Air Handler System: A mechanical system that heats and/or cools air.
Ambient Operating Range: Range in the ambient temperature and relative
humidity over which the instrument is designed to operate.
°C
Bimetal Thermometry: The principal on which bimetallic thermometers
work is that a metal changes volume with temperature and that the amount of
change is not the same for all metals. Thus, by banding two metal strips together
to form a coil, the coil’s movement will correspond to temperature change.
Temperature in Celsius
CL
Clear min/max memory
°F
Temperature in Fahrenheit
Flashing HHH/HI Shorted probe or above maximum temperature
(DM120 and DM450 series)
Blackbody: A theoretical object that radiates the maximum amounts of energy
at a given temperature, and absorbs all the energy incident upon it. (The name
blackbody was chosen because the color black is defined as the total absorption
of light energy). Used in testing calibration of infrared thermometers.
Flashing LLL/LO
Calibration: Comparing an instrument’s measurement against a
known standard.
Calibration Procedure: A procedure to determine and set the parameters
affecting an instruments performance in order to ensure its designed function
within prescribed limits.
Capillary: A tube with a small bore connecting the sensor to the meter.
Celsius (Centigrade): A temperature scale defined by 0°C at the ice point and
100°C at the boiling point of water at sea level.
Clear: To restore a device to a prescribed initial state, usually the zero state.
Open probe or below minimum temperature
(DM120 and DM450 series)
Flashing Temp
Alarm condition (PM200 series, PM400K no alarms)
HI
Temperature is above 300°F/150°C or shorted probe
Kgf/cm2
Pressure is in kilograms per square centimeter
LO
Temperature is below -40°F/-40°C, open probe or
probe is not plugged in
LO-P
Battery is discharged
PSI
Pressure in pounds per square inch
%RH
Relative humidity measurement
SCAN
Multi-channel data collection mode
W Bulb
Wet bulb temperature
1, 2 or 3
Zone being monitored
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • www.cooper-atkins.com
28
Positive Pressure: Condition that exists when more air is supplied to a
space than is exhausted, so the air pressure within that space is greater
than in surrounding areas.
Emmissivity: The ratio of energy emitted by the surface of an object
to the energy emitted by a blackbody at the same temperature.
Environment: The surroundings in which an operation is carried out
including the buildings, facilities, stationary and moveable equipment,
personnel, raw materials, utensils, ingredients and other materials that are
used in the process.
Pressure Drop: A term used to characterize the reduction in air
pressure from the compressor discharge to the actual point of use.
Range: The full scale value for a specific instrument setting.
Evaporator Coil: Also called the cooling coil. Refrigerant is pumped
through this coil and changes state from a gas to a liquid. The part of a
AC/Refrigeration system where cooling or the conditioned air takes place.
Reheat: The application of sensible heat to supply air that has been previously
cooled below the temperature of the conditioned space by either mechanical
refrigeration or the introduction of outdoor air to provide cooling.
Exhaust: In a HVAC context, air exiting a room through a duct.
Resolution: The smallest unit that can be detected and displayed by a
measurement device.
Fahrenheit: A temperature scale defined by 32°F at the ice point and 212°F
at the boiling point of water at sea level.
Return: In an HVAC context, air exiting a room through a duct.
Freezing Point: The temperature at which the substance goes from the
liquid phase to the solid phase.
RH: Relative Humidity in % as opposed to absolute humidity which is in
ppm. 100% RH means at that particular temperature, the air cannot absorb
any more humidity and any additional amount will become water.
As the temperature increases, the % RH drops hence allowing more water
to be absorbed.
HACCP: Hazard Analysis Critical Control Points, is a quality safety system that
focuses on the process of food in an operation to reduce risk.
HARDI: Heating, Air Conditioning & Refrigeration Distributors International
Refrigerant Lines: Also referred to as the vapor and liquid lines, these
copper lines facilitate the flow of refrigerant within an air conditioning or
refrigeration unit.
HVAC/R: Heating, ventilating, air-conditioning, and refrigeration.
Heat Pump: A type of heating unit that extracts heat from the outside air, and
transports it inside to the air handler coil.
Spirit Filled: A glass tube that uses an alcohol or petroleum liquid inside
instead of mercury.
Hygrometer: An instrument used in measuring humidity.
Storage Temperature Range: The ambient temperature range an
instrument can survive in non-operating mode and perform within
specifications.
Ice Point: A comparison of values from a temperature measurement device
to a more accurate device, where the medium is at a reference of 32°F (0°C).
Ice Slurry: Used in calibrating thermometers. A mixture of crushed ice and
water. This brings the temperature to 32°F (0°C) for low-end calibration.
Super Heating: The heating of a liquid above its boiling temperature
without the formation of the gaseous phase. The heating of the gaseous
phase considerably above the boiling point temperature improves the
thermodynamic efficiency of a system.
Infrared Thermometer: An instrument that determines the temperature
of an object by means of detecting and quantifying the infrared radiation
emitted from the object.
Superheat: The difference between the saturated temperature and the
actual vapor temperature.
Infrared: A range of the electromagnetic spectrum extending beyond red
visible light from 760 nanometers to 1000 microns. Infrared is the form of
radiation used for making non-contact temperature measurements.
Supply: In HVAC terms, air which blows out of ducts into a room.
J-Type Thermocouple: The two thermocouple wires that are made of Iron
and Copper-Nickel.
Temperature Error: The difference between the actual temperature and the
temperature measured by an instrument.
K-Type Thermocouple: The two thermocouple wires that are made of
Nickel Chromium and Nickel Aluminum.
Thermistor: A semiconductor device whose resistance changes with the
temperature.
LCD, Liquid Crystal Display: A common type of display used on many
handheld instruments and electronic products. LCD’s are constructed of two
thin transparent layers with grooves filled with a polarizing liquid.
Thermocouple: Has a voltage output proportional to the difference in temperature between the hot junction and the lead wires (cold junction).
LED, Light Emitting Diode: A semiconductor diode that emits light when
voltage is applied.
UL, Underwriters Laboratories: An independent testing agency that
tests products for safety and performance.
Maximum Operating Range: The maximum temperature at which an
instrument or sensor can be safely operated.
Unitary Air Conditioning Equipment: A unitary air conditioner
consists of one or more factory-made assemblies which normally include
an evaporator or cooling coil, an air moving device, and a compressor and
condenser combination.
Thermometer: An instrument that measures temperature.
Min/Max/Average: Some instruments will record the minimum and
maximum temperature and give the average temperature reading based
on the min and max.
Volt: The electrical potential difference between two points in a circuit. One
volt is the potential difference needed to cause one amp of current to pass
through one ohm of resistance.
NIST: National Institute of Standards and Technology, USA
NIST Traceability: Calibration in accordance with and against standards
traceable to NIST. Traceability to NIST is a means of ensuring that reference
standards remain valid and their calibration remains current.
Variable Air Volume System: Air handling system that conditions the air to a
constant temperature and varies the outside airflow to ensure thermal comfort.
Ventilation: The process of supplying and removing air by natural or
mechanical means to and from a space. Such air may or may not be
conditioned (ASHRAE 62).
NSF: (NSF International) Formerly the National Sanitation Foundation, is best
known for its role in the development of standards and criteria for equipment,
products and services that bear upon health. The NSF mark is widely recognized as a sign that the article complies with the applicable NSF standard.
Ventilation Air: Defined as the total air, which is a combination of the air
brought into the system from the outdoors and the air that is being
recirculated within the building.
Ohm: The basic unit of resistance, specified as equal to that of a conductor
in which one amp of current is produced by one volt of potential across
its terminals.
29
Distributed by:
Cooper-Atkins Corporation • 33 Reeds Gap Road • Middlefield, CT 06455
Toll Free: 800-835-5011 or 860-347-2256 • Fax: 860-347-5135 • Email: info@cooper-atkins.com • cooper-atkins.com