26531 Tech Guide
26531 Tech Guide - Panels FOR WEB 10/12/2013 09:48 Page 13
12
PREMIER & SELECT
SELECT Compact
PREMIER & SELECT
PREMIER HE
PREMIER & SELECT.
l
2 and 4 tap connections
l
Stylish and safety conscious round top designs
l
Huge choice of styles and sizes
l
Single, double and triple convectors available
l
High quality white gloss paint finish
PANEL RADIATORS TECHNICAL GUIDE
01.11.2013
Standard, Compact & Metric.
26531 Tech Guide - Panels FOR WEB 10/12/2013 09:48 Page 14
PREMIER & SELECT G e n e r a l S p e c i f i c a t i o n s
13
General Specifications
All MYSON Panel radiators carry a ten year
guarantee from date of manufacture against
defects caused by faulty materials or
manufacture.
Safety Precautions
An epoxy polyester finishing coat in white (RAL 9016) is applied
to all front and rear surfaces allowing the radiator to be fitted
without further painting.
Radiators are hot when in use, and as such, present a risk of
burns to users on prolonged contact. The temperature of a
radiator is dependent on the temperature of the system water,
as set by the system installer or user. Installers and users should
ensure that those who may come into close proximity to hot
radiators are aware of the risk of burns. Installers and users
should take all necessary steps to minimise the risks of burns.
If the risk is significant, consideration should be given to
installing low surface temperature radiators, or to placing guards
in front of the radiators.
Packaging
Heat Output
Every MYSON Panel radiator has plastic corner protection with
durable cardboard edge packaging as well as being fully
wrapped in strong polythene. Each radiator is clearly labelled
with size and type, and packed with the appropriate number of
brackets.
Careful design of an optimum profile for the convector plate,
and welding directly onto the wet and dry sections of the
radiator, have combined to give high heat output per surface
area of radiator.
Paint Finish
Every MYSON Panel radiator is de-greased, phosphated and
primer coated.
Fixings
All MYSON Panel radiators are supplied with concealed wall
mounting brackets. The table of dimensions gives further details.
For the correct installation of radiators it is essential that the
fixing of the radiator is carried out in such a way that it is suitable
for intended use AND predictable misuse. A number of elements
need to be taken into consideration including the fixing method
used to secure the radiator to the wall, the type and condition of
the wall itself, and any additional potential forces or weights that
may happen to be applied to the radiator, prior to finalising
installation. IN ALL CASES IT IS STRONGLY RECOMMENDED
THAT A SUITABLY QUALIFIED PROFESSIONAL INSTALLER OR
SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.
PLEASE NOTE: The fixing materials provided are only intended for installation on
walls made of solid wood, bricks, concrete or on timber-frame stud walls where the
fixing is into the timber. All walls being considered should have no more than a
maximum of 3mm wall finishing. For walls made of other materials, for example
hollow bricks, please consult your installer and/or specialist supplier. ONCE AGAIN,
IF YOU ARE UNSURE, IT IS STRONGLY RECOMMENDED THAT A SUITABLY
QUALIFIED PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES
OUT THE INSTALLATION.
Accessories
Touch up Paint
A handy 12ml container of touch up paint with integral brush
applicator in RAL 9016 is available on request.
Air Vent Key
An alloy key for bleeding and venting is available on request.
Order Code: PREMRADKEY
PANEL RADIATORS TECHNICAL GUIDE
01.11.2013
The recommendations of BS 7593, Code of Practice for
treatment of water in domestic hot water central heating
systems, should be followed where appropriate.
Application
MYSON Panel radiators are for use on two pipe pumped
indirect domestic and commercial central heating installations,
with a maximum working temperature of 100 oC. The system
should be designed in accordance with BS EN 12828:2003 or
BS EN 12831:2003 as appropriate, with particular care taken to
avoid air entry or water discharge.
We do not recommend the use of single feed indirect cylinders,
as the possibility of aeration due to water interchange may lead
to corrosion.
The heat outputs shown in the table below are based on a mean
water to air temperature difference of 50 oC. When the
difference is not 50oC, the output should be multiplied by the
appropriate factor from within the table:
Centigrade
Factor
Fahrenheit
20°C
0.30
36°F
25°C
30°C
35°C
0.41
0.51
0.63
45°F
54°F
63°F
40°C
45°C
0.75
0.87
72°F
81°F
50°C
55°C
1.00
1.13
90°F
99°F
60°C
65°C
1.27
1.41
108°F
117°F
70°C
1.55
126°F
PREMIER & SELECT
BS EN 442
All MYSON Panel radiators are manufactured
and tested to BS EN 442. Every radiator
carries the BS Kitemark which certifies
independent approval of heat output and
verifies production under a quality system
to BS EN ISO 9001.
The installation work must be carried out in accordance with
recognised good practice, and precautions taken to avoid
contamination which could lead to corrosion. If a corrosion
inhibitor or other water treatment is to be used, the
Manufacturer’s Instructions must be strictly followed.
Example:
Heat emission required:
2000 Watts
Room air temperature required:
20oC
Mean water temperature in radiator:
65 oC
1. Temperature difference = 65-20
2. From Factor Table 45oC gives a factor of:
3. Divide required heat emission
by factor = 2000
0.87
4. From selection tables choose any
radiator rated at 2298 Watts or more.
= 45 oC
0.87
= 2298 Watts
PANEL RADIATORS TECHNICAL GUIDE
01.11.2013
Approval and Certification
26531 Tech Guide - Panels FOR WEB 10/12/2013 09:48 Page 18
SELECT Compact Te c h n i c a l I n f o r m a t i o n
17
Weight and Water Contents per Metre Length
Height (mm)
300
Weight
(kg)
Type
400
Water
Content (l)
Weight
(kg)
450
Water
Content (l)
Weight
(kg)
500
Water
Content (l)
Weight
(kg)
600
Water
Content (l)
Weight
(kg)
700
Water
Content (l)
Weight
(kg)
Water
Content (l)
11G
SSG
8.4
1.7
11.2
2.1
N/A
N/A
13.8
2.6
16.7
3.0
19.3
3.5
21G
SXG
14.1
3.4
18.7
4.3
N/A
N/A
23.2
5.2
27.9
6.2
32.3
7.0
22G
SDG
15.8
3.4
21.2
4.3
N/A
N/A
26.6
5.2
32.0
6.2
37.3
7.0
33G
STG
24.5
5.1
N/A
N/A
37.4
7.5
N/A
N/A
50.2
9.8
N/A
N/A
Mounting Positions, Dimensions and Wall Brackets
Wall Brackets
Supplied with Type 11, 21, 22
78
62
97
70
129
102
Supplied with Type 33 only
5.6
170
152
24
39
32
22
14
A
A
A
SX
&
SD
B
WALL
WALL
SS
WALL
22.5
B+11
22.5
A
79
69
Type 21
Type 22
14.6
Type 11
only
158
Min
69
17
10
32
Type 21& 22
15
32.5
Fixing Hole
Dimensions
12
23
Type 33
only
100
Min
78
100
Min
190
Min
100
Min
62
9.6
Nominal
Height (mm)
A
(mm)
B
(mm)
300
400
450
500
600
700
250
350
400
450
550
650
142
242
292
342
442
542
Type 33
SELECT COMPACT
Type 11
190
Min
46
100
Min
190
Min
23
Bracket Positions and Dimensions
1800 & above = (L / 2) + 17mm
1800 & above = (L / 2) - 17mm
Type 11
1800 & above = (L / 2) - 50mm
100
150
150
117
117
83
83
L
C
1800 & above = (L / 2) + 33mm
1800 & above = L / 2
Type 21, 22 & 33
Nominal
Height (mm)
C
(mm)
300
400
450
500
600
700
120
220
270
320
420
520
1800 & above = (L / 2) - 33mm
166.6
166.6
133.3
133.3
100
L
Connections
Operating Pressures
All MYSON SELECT Compact radiators are fitted with 4 - 1/2 inch BSP
Every MYSON S ELECT Compact radiator is tested to a pressure of
10.5 bar (152.5 psi) and is suitable for a working pressure of up to 8.0 bar
(117.1 psi).
connections.
Air Vents
An air vent and plug are packed with every radiator.
PANEL RADIATORS TECHNICAL GUIDE
01.11.2013
PANEL RADIATORS TECHNICAL GUIDE
01.11.2013
100
26531 Tech Guide - Panels FOR WEB 10/12/2013 09:58 Page 27
SELECT Compact H e a t O u t p u t s
G
Type 33
Coming
Soon!
Nominal Length (mm - inches)
Double Panel “Xtra” - Type 21G
Double Convector - Type 22G
Triple Convector - Type 33G
(with factory fitted top grille and side panels)
(with factory fitted top grille and side panels)
(with factory fitted top grille and side panels)
Heat Outputs
@ ΔT 50°C
Heat Outputs
@ ΔT 30°C
Watts
Btu/h
Watts
Btu/h
Order Code
Heat Outputs
@ ΔT 50°C
Heat Outputs
@ ΔT 30°C
Watts
Btu/h
Watts
461
1572
238
813
SX 30 60G
2620
3669
4717
397
556
715
1355
1897
2439
SX 30 100G
SX 30 140G
SX 30 180G
Order Code
Btu/h
300 - 12
600 - 24
700 - 28
800 - 31
1000 - 39
1400 - 55
1800 - 71
2000 - 79
2400 - 94
218
328
745
1119
113
169
386
576
SS 30 40G
SS 30 60G
546
764
983
1092
1310
1863
2607
3354
3726
4470
281
393
506
562
674
958
1341
1726
1917
2300
SS 30 100G
SS 30 140G
SS 30 180G
SS 30 200G
SS 30 240G
768
1075
1382
Nominal Height
400 mm
500 - 20
600 - 24
700 - 28
800 - 31
900 - 35
1000 - 39
1100 - 43
1200 - 47
1300 - 51
1400 - 55
1600 - 63
1800 - 71
356
427
498
569
640
711
782
853
924
995
1138
1280
1215
1457
1699
1941
2184
2426
2668
2910
3153
3395
3883
4367
183
220
256
293
329
366
402
439
475
512
585
658
625
749
874
998
1123
1247
1372
1496
1621
1746
1996
2246
SS 40 50G
SS 40 60G
SS 40 70G
SS 40 80G
SS 40 90G
SS 40 100G
SS 40 110G
SS 40 120G
SS 40 130G
SS 40 140G
SS 40 160G
SS 40 180G
486
583
680
778
875
972
1069
1166
1264
1361
1555
1750
Nominal Height
450 mm
600 - 24
800 - 31
1000 - 39
1200 - 47
1400 - 55
1600 - 63
1800 - 71
2000 - 79
Nominal Height
500 mm
400 - 16
500 - 20
600 - 24
700 - 28
800 - 31
900 - 35
1000 - 39
1100 - 43
1200 - 47
1400 - 55
1600 - 63
1800 - 71
2000 - 79
2400 - 94
347
434
521
608
694
781
868
955
1042
1215
1389
1562
1736
2083
1184
1481
1778
2074
2368
2665
2962
3258
3555
4146
4739
5330
5923
7107
178
223
268
312
357
401
446
491
535
624
714
803
892
1070
608
761
914
1066
1217
1369
1522
1674
1827
2130
2435
2739
3044
3652
SS 50 40G
SS 50 50G
SS 50 60G
SS 50 70G
SS 50 80G
SS 50 90G
SS 50 100G
SS 50 110G
SS 50 120G
SS 50 140G
SS 50 160G
SS 50 180G
SS 50 200G
SS 50 240G
467
584
700
817
934
1050
1167
1593
1991
2389
2787
3185
3584
3982
239
299
359
418
478
538
598
816
1020
1224
1428
1632
1836
2040
SX 50 40G
SX 50 50G
SX 50 60G
SX 50 70G
SX 50 80G
SX 50 90G
SX 50 100G
1400
1634
1867
2101
4778
5575
6371
7167
717
837
957
1076
2448
2856
3264
3672
SX 50 120G
SX 50 140G
SX 50 160G
SX 50 180G
Nominal Height
600 mm
400 - 16
500 - 20
600 - 24
700 - 28
800 - 31
900 - 35
1000 - 39
1100 - 43
1200 - 47
1300 - 51
1400 - 55
1600 - 63
1800 - 71
2000 - 79
2400 - 94
407
509
611
713
814
916
1018
1120
1222
1323
1425
1629
1832
2036
2440
1389
1737
2085
2433
2777
3125
3473
3821
4169
4514
4862
5558
6251
6947
7643
208
261
313
365
417
469
521
574
626
678
730
834
938
1043
1251
711
890
1068
1246
1423
1601
1779
1957
2136
2312
2491
2847
3202
3558
4270
SS 60 40G
SS 60 50G
SS 60 60G
SS 60 70G
SS 60 80G
SS 60 90G
SS 60 100G
SS 60 110G
SS 60 120G
SS 60 130G
SS 60 140G
SS 60 160G
SS 60 180G
SS 60 200G
SS 60 240G
542
678
813
949
1084
1220
1355
1491
1626
1762
1897
2168
2439
1849
2312
2774
3236
3699
4161
4623
5086
5548
6010
6473
7397
8322
276
345
415
484
553
622
691
760
829
898
967
1105
1244
943
1179
1414
1650
1886
2122
2357
2593
2829
3065
3300
3772
4243
300 - 12
400 - 16
500 - 20
600 - 24
700 - 28
800 - 31
900 - 35
1000 - 39
1200 - 47
1400 - 55
1600 - 63
348
464
581
697
813
929
1045
1161
1393
1625
1858
118
1583
1982
2378
2774
3170
3566
3961
4753
5545
6339
178
237
297
356
415
474
534
593
711
830
949
608
808
1012
1214
1416
1619
1821
2023
2427
2831
3237
SS 70 30G
SS 70 40G
SS 70 50G
SS 70 60G
SS 70 70G
SS 70 80G
SS 70 90G
SS 70 100G
SS 70 120G
SS 70 140G
SS 70 160G
615
769
922
1076
1230
1383
1537
1844
2152
2459
2098
2622
3147
3671
4195
4720
5244
6293
7342
8391
312
390
468
546
624
703
781
937
1093
1249
1065
1332
1598
1864
2131
2397
2663
3196
3729
4262
Nominal Height
300 mm
SELECT COMPACT
Single Convector - Type 11G
(with factory fitted top grille and side panels)
Nominal Height
700 mm
1658
1990
2322
2653
2985
3316
3648
3980
4311
4643
5306
5970
250
300
350
400
450
500
550
600
650
700
800
901
853
1024
1195
1366
1536
1707
1878
2048
2219
2390
2731
3073
SX 40 50G
SX 40 60G
SX 40 70G
SX 40 80G
SX 40 90G
SX 40 100G
SX 40 110G
SX 40 120G
SX 40 130G
SX 40 140G
SX 40 160G
SX 40 180G
Heat Outputs
@ ΔT 50°C
Heat Outputs
@ ΔT 30°C
Watts
Btu/h
Watts
Btu/h
580
676
773
966
1352
1739
1932
2318
1978
2307
2637
3296
4614
5933
6592
7910
297
346
396
494
692
890
989
1187
1012
1181
1351
1687
2362
3037
3374
4049
SD 30 60G
SD 30 70G
SD 30 80G
SD 30 100G
SD 30 140G
SD 30 180G
SD 30 200G
SD 30 240G
616
739
862
986
1109
1232
1355
1478
1602
1725
1971
2218
2102
2522
2943
3363
3783
4204
4624
5044
5465
5885
6726
7566
314
376
439
502
564
627
690
753
815
878
1003
1129
1070
1284
1498
1712
1926
2140
2354
2568
2782
2996
3424
3852
SD 40 50G
SD 40 60G
SD 40 70G
SD 40 80G
SD 40 90G
SD 40 100G
SD 40 110G
SD 40 120G
SD 40 130G
SD 40 140G
SD 40 160G
SD 40 180G
Order Code
594
743
891
1040
1188
1337
1485
1634
1782
2079
2376
2673
2970
3564
2027
2533
3040
3547
4053
4560
5067
5574
6080
7094
8107
9120
10134
12160
301
376
451
526
601
677
752
827
902
1053
1203
1353
1504
1804
1026
1283
1539
1796
2052
2309
2565
2822
3078
3591
4104
4617
5130
6156
SD 50 40G
SD 50 50G
SD 50 60G
SD 50 70G
SD 50 80G
SD 50 90G
SD 50 100G
SD 50 110G
SD 50 120G
SD 50 140G
SD 50 160G
SD 50 180G
SD 50 200G
SD 50 240G
SX 60 40G
SX 60 50G
SX 60 60G
SX 60 70G
SX 60 80G
SX 60 90G
SX 60 100G
SX 60 110G
SX 60 120G
SX 60 130G
SX 60 140G
SX 60 160G
SX 60 180G
691
864
1036
1209
1382
1554
1727
1900
2072
2245
2418
2763
3109
3454
4145
2357
2946
3536
4125
4714
5303
5893
6482
7071
7660
8250
9428
10607
11785
14142
348
435
522
609
696
783
870
957
1043
1130
1217
1391
1565
1739
2087
1187
1483
1780
2077
2374
2670
2967
3264
3560
3857
4154
4747
5341
5934
7121
SD 60 40G
SD 60 50G
SD 60 60G
SD 60 70G
SD 60 80G
SD 60 90G
SD 60 100G
SD 60 110G
SD 60 120G
SD 60 130G
SD 60 140G
SD 60 160G
SD 60 180G
SD 60 200G
SD 60 240G
SX 70 40G
SX 70 50G
SX 70 60G
SX 70 70G
SX 70 80G
SX 70 90G
SX 70 100G
SX 70 120G
SX 70 140G
SX 70 160G
783
979
1175
1371
1566
1762
1958
2350
2741
3133
2672
3340
4008
4676
5345
6013
6681
8017
9353
10689
393
492
590
688
787
885
983
1180
1377
1573
1342
1678
2013
2349
2684
3020
3355
4026
4697
5368
SD 70 40G
SD 70 50G
SD 70 60G
SD 70 70G
SD 70 80G
SD 70 90G
SD 70 100G
SD 70 120G
SD 70 140G
SD 70 160G
Heat Outputs
@ ΔT 50°C
Heat Outputs
@ ΔT 30°C
Watts
Watts
Btu/h
Btu/h
27
Order Code
808
2758
413
1409
ST 30 60G
1347
4597
688
2349
ST 30 100G
2694
9195
1377
4698
ST 30 200G
1019
1359
1699
2039
2379
2718
3058
3398
3479
4639
5799
6958
8118
9278
10438
11597
518
690
863
1036
1209
1381
1554
1726
1767
2356
2945
3535
4124
4712
5301
5891
ST 45 60G
ST 45 80G
ST 45 100G
ST 45 120G
ST 45 140G
ST 45 160G
ST 45 180G
ST 45 200G
942
3216
473
1614
ST 60 40G
1414
4825
710
2423
ST 60 60G
1885
6433
947
3229
ST 60 80G
2356
8041
1183
4036
ST 60 100G
2827
9649
1420
4843
ST 60 120G
3298
3770
4241
4712
11257
12866
14474
16082
1656
1893
2130
2366
5650
6459
7266
8073
ST 60 140G
ST 60 160G
ST 60 180G
ST 60 200G
N.B. The tabulated heat outputs are quoted at a mean water to air temperature difference of 50oC and 30oC.
SELECT COMPACT
SELECT Compact H e a t O u t p u t s
PANEL RADIATORS TECHNICAL GUIDE
01.11.2013
26