modul-r® fire alarm control panels mr-2100/mr-2200

modul-r® fire alarm control panels mr-2100/mr-2200
MODUL-R®
FIRE ALARM CONTROL PANELS
MR-2100/MR-2200
Addressable Fire Alarm Control Panels
Features
•
•
•
•
•
•
•
•
•
•
•
•
MR-2100/MR-2200 Fire Alarm Control Panel
(shown with optional LED modules)
Description
Secutron's MR-2100 and MR-2200 addressable input fire
alarm control panels provide flexible and cost effective
operation to satisfy system requirements for both economy
and capability. Their modular design assures that as system
needs and applicable codes evolve, fire alarm control panel
functions can be updated as required.
Optional networking modules allows the MR-2100 and
MR-2200 to be connected to a Secutron network to provide
additional input circuits, visual zones, programmable
notification appliance (bell) circuits, and relays. Up to 254
control and annunciator units can be networked together. The
network is a DCLR (Data Communications Link, Redundant)
configuration loop.
The MR-2100 models provide a single addressable input
Signaling Line Circuit for support of up to 198 addressable
devices; up to 99 detectors and up to 99 control/monitor
modules.
The MR-2200 models provide two SLCs for support of
198 devices on each allowing a total capacity of up to 396
addressable devices; up to 198 detectors and up to 198
control/monitor modules total.
Option modules are available and can be conveniently field
installed. Modules are available for: additional NAC output
circuits & function relays, local LED annunciation, additional
NAC power, and Central Station (DACT) or Remote Station
(DACT or CITY Module) connection.
•
•
•
•
•
•
•
•
•
UL, ULC, CSFM and MEA Listed
UL Listed to Standard 864 “Standard for Control Units
for Fire Protective Signaling Systems”
ULC Listed to CAN/ULC-S527 “Standard for Control
Units for Fire Alarm Systems”
MR-2100 provides a Single Addressable Input Signaling
Line Circuit (SLC) for up to 198 Addressable Devices
MR-2200 provides Dual Addressable Input Signaling
Line Circuits for up to 396 Addressable Devices
SLCs are selectable for either Class A (Style 6) or Class
B (Style 4) operation
Two Notification Appliance Circuits (NACs), Class A
(Style Z) or Class B (Style Y); expandable to eight NACs
with optional MRNC2 modules
Four programmable functions relays, Form C; expandable
to sixteen relays with MRRL4 modules
Programmable cross-zoning functions, day/night mode,
and selective control operations
Two aux. power outputs, 500 mA @ 24 VDC each
4.3 A Power supply with integral battery charger provides
2.5 A for NACs and Auxiliary Outputs; Expandable to
provide up to 7 A NAC Current
Four additional communications ports for Dialer, PC
Interface, Voice Evacuation System, and Remote
Annunciators
Optional Style 7 (DCLR) MR network peer-to-peer
communications
LCD/LED system status display with optional MRLD8
LED zone display modules (required for ULC listed
applications)
Surface/flush mount cabinet with dead front construction
allows up to 12 Ah batteries internally mounted
Battery charger is capable of charging up to 35 Ah
mounted in an external battery cabinet
Cabinet doors are removable for easy installation
Terminal blocks are removable for easy wiring
Operating program and database can both be uploaded/
downloaded using a Windows® based PC with Secutron
Programming Software
Non-volatile event history log stores 1000+ events
5 year warranty
Programming the MR-2100/MR-2200 consists of two
convenient and easy operations. Input circuit programming
and special features (such as cross zoning functions, day/
night mode, selective control operations, etc.) is performed
from an externally generated database produced on a
Windows® based PC. System parameters and control panel
display and operation functions are conveniently programmed
from the on board LCD and keypad.
MEA
approved
S6619
S8646
7165-1429:119
7170-1429:121
352-03-E
Issue 1
Page 1 of 6
SECUTRON INC.
Canada 25 Interchange Way, Vaughan (Toronto), Ontario L4K 5W3 Telephone: (905) 695-3545 Fax: (905) 660-4113 • Web Page: www.secutron.com
U.S.A. 60 Industrial Parkway, Cheektowaga (Buffalo), NY 14227 Telephone: (888) 695-3545 Fax: (888) 660-4113 • E-mail: mail@secutron.com
Catalog Number 1005 • Not to be used for installation purposes.
Main Control Unit
System controls consist of eight system switches, an LCD
readout, and display entry switches. The display entry
keypad is used for technical functions, system/detector
maintenance, history recall, device and circuit disarming,
and for manual operation of addressable output modules,
relay modules, and notification appliance (bell) circuits.
Operator Keys
There are eight operator keys. In the figure below, the
keys are located on the lower left and are labeled “System
Controls.” The LEDs associated with these keys are used to
display function status. The top three keys are pre assigned
and are: Acknowledge, Signal Silence, and System Reset.
The bottom five keys are user-assignable, selected for the
following functions: Lamp Test, Relay Disconnect, Test
Mode, Signal Disconnect, Common Disconnect, General
Alarm, Selectable Switch Function On, Switch Function Off,
or Manual Restart.
The panel local sounder will beep once when a valid key is
pressed and beep three times if an invalid or unavailable key
is pressed. Key presses are recorded in the history log.
Addressable Input Circuits
Up to 99 addressable detectors and up to 99 addressable
control/monitoring modules may be connected per SLC for a
total of 198 addressable devices. MR-2100 models provide a
single SLC output, MR-2200 models provide dual SLCs.
Addressable monitoring modules can be programmed for
alarm or supervisory functions. Control modules are available
for dry contact or supervised output functions.
NAC Outputs
Standard are two NACs rated 2 A maximum. NAC output
voltage is a nominal 24 VDC, full wave rectified. NAC
expansion can be up to eight NACs by using MRNC2 NAC
expander modules.
Auxiliary Outputs
Two auxiliary power outputs are provided, each rated for 500
mA at a nominal 24 VDC, filtered and regulated.
Function Relays
The panel comes with four programmable Form C function
relays rated 2 A @ 30 VDC resistive. Total function relays
can be expanded to 16 by using MRRL4 relay expander
modules. Relays can be programmed as Common Alarm,
Common Trouble, Common Supervisory, or general purpose
functions.
INSTRUCTIONS:
SYSTEM CONTROLS
SYSTEM DISPLAY AND PROGRAMMING
Acknowledge
ALARM
Signal Silence
ALARM
SUPERV
TROUBLE
MONITOR
SUPERVISORY
Power Supply and Expansion Transformer
System Reset
TROUBLE
AC
MONITOR
User Assigned
BYPASS
GROUND FAULT
1
2
3
ENTER
4
5
6
CLEAR
7
8
9
HOME
NAC TROUBLE
Each MR-2100/2200 fire alarm control panel is shipped with
either a 120 VAC or 240 VAC transformer as determined by
the base model number. Total NAC power can be increased
by adding a second transformer of the same voltage,
MR12VAC or MR24VAC.
LAMP
TEST
The standard power supply provides 2.5 A @ 24 VDC (full
wave rectified, unfiltered) for the total of NAC and Auxiliary
power output. With the addition of an optional transformer,
the total NAC and Auxiliary power output is increased to 8 A
with up to 7 A available for NACs.
MR-2100/2200 Main Control Panel
Display Information
The Main Control Panel LCD readout is backlighted and
displays 4 lines with 20 characters per line. With AC power
present, the LCD backlighting turns off automatically within
5 minutes if no activity occurs. During AC power failure, the
backlighting will turn off within 30 seconds without activity.
Enclosure Details
During normal conditions the display is the main menu
which includes the date and a 24 hour clock. During alarm
conditions, the first or last (selectable) events of highest
priority will be displayed instead of the main menu. A
status summary screen lists the number of active alarm,
supervisory, or trouble events indicating “SYSTEM OFF
NORMAL.”
Both the outer door and dead front doors are removable.
The hardware plate holds the main printed circuit board
and transformer(s). This enclosure holds two transformers,
up to three NAC or Relay expander modules, and one
communicator module.
The enclosure includes the mounting box, outer door, dead
front door, and hardware plate. It can be flush or surface
mounted without requiring a separate trim ring.
The backbox is included with the fire alarm control panel and
includes an outer lip around the perimeter to provide a built in
trim for semi-flush mounting applications. The door conceals
the outer lip and provides a neat and clean appearance for
surface mounted box applications.
Page 2 of 6
SECUTRON INC.
Catalog Number 1005
Not to be used for installation purposes.
Issue 1
Optional Features
Compatible Products
NAC Expander Board Model MRNC2
LCD Annunciator Model MR-2644
NAC Expander Boards provide two additional NAC outputs.
Up to three modules can be added within the basic enclosure
and can be any combination of NAC or Relay expanders.
NAC Expander Board NACs are rated for 2 A @ 24 VDC
each, the same as the standard NACs.
For remote information annunciation, model MR-2644 is an
LCD status annunciator with display, general system status
LEDs, and general function keys.
(MR-2644 is not ULC Listed.)
Relay Expander MRRL4
Relay Expander module MRRL4 provides four additional
function relay outputs. Each relay provides a Form C contact
rated 2 A @ 30 VDC resistive with dry contacts requiring
connection to a power limited source.
Eight Zone LED Module MRLD8
For local LED panel mounted zone annunciation, the MRLD8
module provides eight zones of LED annunciation, readily
visible on the front of the control panel cabinet. Up to three
LED modules can be mounted on the front of the cabinet.
Each module has label pockets to locally identify zone
locations.
NOTE: An MRLD8 LED module is required for ULC listed
applications.
DACT Module - MRDL
The optional Digital Alarm Communicator Transmitter (DACT)
module is added to the system to provide Remote Station
monitoring of system alarms, troubles, and supervisory
conditions. Communications are available for : Contact ID,
SIA, or 10/20 bps formats.
Use of the DACT module requires that two telephone lines
be provided for connection to the DACT. Service must be
arranged with a Central Station monitoring facility for Remote
Station Service.
(MRDL is not ULC listed).
MR-2644 Remote LCD Annunciator
LED Annunciator Model MR-2614
Model MR-2614 is a status annunciator with LED zone
display, general system status lights, and general function
keys. It provides up to 72 LED zones with three status LEDs
per zone.
City Connection Module MRCTYB
Optional module MRCTYB can be configured for remote
Station (reverse polarity) or Municipal Master (local energy)
service. The MRCTYB can transmit alarm, trouble, and
supervisory conditions when configured for reverse polarity
operation. Alarm conditions are only reported when configured
for Municipal Master operation.
Note: The MR-2100/MR-2200 accepts either the MRDL or
the MRCTYB module.
MR-2614 Remote LED Annunciator
Peer-to-Peer Networking
MR-2100/2200 control panels can be networked to other
control units for up to a total of 254 network members, each
using Style 7 (DCLR) loop communications. One control unit
is designated as the master control unit for the network and
diagnostics can be done at any control unit.
Programming of each individual control unit is done at that
unit. Each control unit operates independently in a standalone
mode if network communications are lost.
Issue 1
SECUTRON INC.
Catalog Number 1005
Not To Be Used For Installation Purposes.
Page 3 of 6
Specifications
Input Power
120 VAC, 60 Hz
2 A maximum
240 VAC, 50 Hz
1 A maximum
Ratings are per transformer; one additional transformer may be added to increase
capacity
Mechanical
Overall Dimensions with Door
16-7/8” W x 29-1/2” H x 5-1/4” D (429 mm x 749 mm x 133 mm) [see page 5 for mounting box detail]
Environmental
Temperature Range
32° to 120°F (0° to 49° C)
Humidity Range
Up to 93% RH, non-condensing @ 90° F (32° C) maximum
Signaling Line Circuit Ratings
Voltage
24 VDC nominal, 27.5 VDC maximum
Max. number of devices
MR-2100, Single SLC: 198 total, 99 detector, 99 control/monitor modules
MR-2200, Dual SLCs: 396 total, 198 detectors, 198 control/monitor modules
Compatible devices
Refer to list on page 5
Maximum line length
3045 m (10,000 ft) (12 AWG, 3.31 mm2)
Operation modes
Available as Style 6 (Class A) or Style 4 ( Class B); T-tapping is allowed with Style 4 (Class B) connections
only
Notification Appliance Circuit Output Circuits, Standard and Expansion NACs
NAC Output Ratings
2 A maximum per NAC; 24 V full wave rectified DC output; power limited
NAC Current, Standard with
One Transformer
Total of NACs + Auxiliary Power = 2.5 A maximum
(if Aux. Power Total = 500 mA; NAC power = 2 A maximum)
NAC Current with Optional
Transformer
Total NAC current = 7 A maximum
Total of NACs + Auxiliary Power = 8 A maximum
(optional transformer MR12VAC or MR24VAC)
Function Relay Output Circuits, Standard and Expansion Relays
All Relays
2 A @ 30 VDC resistive; Form C contacts; requires power limited source
Power Output Circuits
Auxiliary Power Outputs
(two outputs)
Each output is rated 500 mA @ 24 VDC, filtered, regulated, and power limited; maximum ripple voltage
= 600 mVpp
Battery Information
Battery Charger
current limited float charger for sealed lead acid batteries
Float Charge
27.5 VDC
Charging Current
2.7 A maximum, no auxiliary loads; 1.7 A nominal with 0.5 A on each Auxiliary output
Maximum Battery Capacity
12 Ah maximum size internal to cabinet;
35 Ah maximum size allowed, requires model MR2978 External Battery Cabinet
Communications Ports
ANN (annunciator port)
Fixed baud rate @ 4800 bps; for use with MR-2614 or MR-2644 Annunciators (refer to individual product
Installation Instructions for capacities and wiring distances)
RS-232-2 (MV-2700 or GRID)
Fixed baud rate @ 9600 bps; 20 ft (6m) maximum distance; for use with MV-2700 Voice Evacuation
System or GRID Graphical PC Display
CON4 (Dialer/City Module Port)
Fixed baud rate @ 4800 bps; for use with MRDL Digital Communicator Module or MRCTYB City Module
J1 (Service port or serial printer
port)
Fixed baud rate @ 9600 bps; 6 m (20 ft) maximum distance; for use with Service/Programming PC
(using Windows 95 or 98); or for serial input printer
Network Ports
COM1, COM2
(Secutron MR peer to peer
network, redundant DCLR)
Network Wiring Parameters
(maximum line resistance =
680 ohms)
Page 4 of 6
Standard Protocol: 10km (33,000 feet; 6.2 miles) maximum distance between nodes, minimum 28
AWG wires (0.081 mm2);
Total panel capacity varies with programmable baud rate: up to 254 panels with 9600, 4800, and
2400; up to 200 panels at 1200
RS-232 Protocol: up to 20 m (66 ft), typically for connection to external modem
Baud Rate
9600
4800
2400
1200
Maximum Capacitance
100 nF
220 nF
470 nF
680 nF
SECUTRON INC.
Catalog Number 1005
Not to be used for installation purposes.
Maximum Network Nodes
254
254
254
200
Issue 1
Compatible Addressable Devices
Compatible Addressable Devices Reference Information
Model
Description
MRI-1251B
Ionization type smoke detector
Typical Current Draw µA
300
MRI-2251B
Photoelectric type smoke detector
300
MRI-2251TB
Photoelectric type smoke detector with thermal element
300
MRI-2251TMB
Acclimate Photo-Thermal Detector
300
MRI-DH200PL
Intelligent photoelectric duct smoke detector (w/o relays)
300
MRI-DH200RPL
Intelligent photoelectric duct smoke detector with two, 10 A Form C relays
MRI-5251B
Thermal detector
200
MRI-5251RB
Thermal detector with rate of rise
200
MRI- M500DM
Dual input monitor module
300
MRI-M500M
Monitor module, Classes A/B initiating
300
MRI-M501M
Mini-monitor module, Class B initiating
300
MRI-M502M
Monitor module for 2-wire smoke detectors Classes A/B initiating
200
MRI-M500S
Supervised control module
300
MRI-M500R
Dual Form C relay module
300
MRI-M500X
Fault isolator module
450
**
MR-2100 & MR-2200 Back Box Dimension Reference
14-1/2" (368 mm)
7/8" (23 mm)
lip each side
Door outline reference; dimensions:
16-7/8" W x 29-1/2" H x 1-1/4" D
(429 mm x 749 mm x 172 mm)
3/4" (19 mm) lip
top and bottom
16-1/8" (410 mm)
4"
(102 mm)
3" (76 mm)
29"
(740 mm)
21-3/4"
(552 mm)
5-1/4"
(133 mm)
26-1/2"
(673 mm)
27-1/2"
(699 mm)
1-1/4"
(32 mm)
8-1/2"
(216 mm)
Issue 1
SECUTRON INC.
Catalog Number 1005
Not to be used for installation purposes.
Page 5 of 6
Ordering Information
MR-2100 and MR-2200 Fire Alarm Control Panels
Model
Description
MR-2100R
Single SLC Fire Alarm Control Panel, 120 VAC input, Red
MR-2100B
Single SLC Fire Alarm Control Panel, 120 VAC input, Beige
MR-2200R
Dual SLC Fire Alarm Control Panel, 120 VAC input, Red
MR-2200B
Dual SLC Fire Alarm Control Panel, 120 VAC input, Beige
MR-2100R2
Single SLC Fire Alarm Control Panel, 240 VAC input, Red
MR-2100B2
Single SLC Fire Alarm Control Panel, 240 VAC input, Beige
MR-2200R2
Dual SLC Fire Alarm Control Panel, 240 VAC input, Red
MR-2200B2
Dual SLC Fire Alarm Control Panel, 240 VAC input, Beige
Standby Current
Alarm Current
110 mA
175 mA
110 mA
175 mA
Backbox, Order if required prior to delivery of Fire Alarm Control Panel
MR20BOXR
Backbox, Red
MR20BOXB
Backbox, Beige
Note: Backbox is included with Fire Alarm Control Panels listed above, order these standalone boxes if required for early installation.
Optional Panel Modules
MRNC2*
Dual NAC Expansion Module
(output ratings are the same as standard NACs)
10 mA
65 mA
MRRL4*
Four Relay Module
5 mA
17 mA/relay
MRLD8
Eight (8) LED Module; Quantity 3 maximum, 2 maximum if
for Canada (Alarm current is for 3 devices in alarm, add 5 mA
each if more) ULC listed applications require a minimum of one
MRDL8 LED module
5 mA
15 mA
(see current note)
MR12VAC
Expansion Transformer, 120 VAC
NA
NA
MR24VAC
Expansion Transformer, 240 VAC
NA
NA
MRDL**
DACT Module
33 mA
60 mA
MRCTYB**
City Connection Module
20 mA
20 mA
Optional Network
Modules
Port 1 Operation
Port 2 Operation
Standard
Standard
MR22NTWR1
RS-232
Standard
MR22NTWR2
Standard
RS-232
MR22NTWR12
RS-232
RS-232
MR22NTWR
Batteries
MR-6V4.5AH
4.0 Ah, 6 V Battery, order in quantity of 4 for 24 V set
MR-12V7.2AH
7.0 Ah, 12 V Batteries, order in quantity of 2 for 24 V set
MR-12V12AH
12 Ah, 12 V Batteries, order in quantity of 2 for 24 V set
MR-12V18AH
18 Ah, 12 V Batteries, order in quantity of 2 for 24 V set, requires external battery cabinet
MR-12V26AH
26 Ah, 12 V Batteries, order in quantity of 2 for 24 V set, requires external battery cabinet
MR-12V34AH
34 Ah, 12 V Batteries, order in quantity of 2 for 24 V set, requires external battery cabinet
Service Parts
SMR21MPCB
Main PC Board, Single SLC
SMR22MPCB
Main PC Board, Dual SLC
SMR22DPCB
Display Board
SMR22HARN
Wiring Harness for Main Board to Option Module, Long
* Select any combination for up to 3 modules total.
** Quantity one maximum from these modules.
Page 6 of 6
SECUTRON INC.
Catalog Number 1005 • Not to be used for installation purposes.
Issue 1
Secutron reserves the right to make changes at any time without notice in prices, colors, materials, components, equipment, specifications and models and also to discontinue models.
Modul-R® is a trademark of Secutron Inc.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising