PCM Vanguard UPS-1
 ON LINE UPS- Vanguard UPS
(TT
ON LINE UPS -
Perfect solution for
Industrial users.
Vanguard UPS
Multi Functional double conversion LCD On-Line UPS
* True on-line technology provides all power protection * UPSMON plus software monitoring
* Pure sine-wave output with less than 3% THD Hot swappable battery by user *
« Fully digitized microprocessor controlled Emergency Power Off function
Cold start function (DC power on) * Support USB communication
* Lightning and surge protection * High efficiency mode selectable
* Short Circuit and overload protection * Battery remain time display
* Advanced battery management (ABM) + Multiple language LCD display
* Automatic battery charge in UPS off mode s On line output voltage selected
* Battery replacement warning * LCD display front panel
* Automatic diagnostics & battery check * Power factor correction
+ RS-232 communication port with monitoring software * means function available only
» Load segmentation receptacles controllable * for model VGD-700-3000
* Fan speed auto control when loads varies
* Extended back up time with battery pack
* Network/fax/modem surge protection : 1
E Ц паи
"e y"
q = su!
a | = dl mo
|| | a
4 0
| : 8
Г = 5 | y
par || a x 33 zu
|1} = = y = | ой
E | ptt
| = E A
E y i
: 2 Е вия,
- S : w R shar
| e y
и
e"
VGD-700-1500VA vCD-2K-3K VA VGD-4K-5KKVA VCD-6KVA VGD-12K-20KVA
PRODUCT INTRODUCTION :
As business becomes increasingly dependent on technology for their fundamental operation, the need for system
availability is of paramount importance.
The Powercom Vanguard series UPS is designed for those applications that need maximum protection in the 700VA - 20KVA range.
With its high-frequency, double-conversion online topology, providing nonstop clean sine wave power, advanced communications
and space-saving tower design, the Powercom Vanguard series is the ideal power solution for networks, web servers,
telecommunications applications and other critical electronic equipment,
Available from: www.dueltek.com.au
Best Power Protection ,
Your Power Solution
In addition to its proven design, the Powercom Vanguard series offer Advanced Battery Management (ABM) and sophisticated
communications to provide maximum system availability. ABM uses a three-stage charging technique that not only doubles
service life of battery but optimizes charging time.
The Powercom Vanguard series's communications are flexible, allowing for local, network or remote monitoring and management.
The Powercom Vanguard includes the latest version of Powercom's UPSMON Software Suite, which provides power monitoring and
shutdown software.
With the Powercom Vanguard, Powercom delivers a best-in-class power solution
for maximum system availability, and peace of mind.
VGD-700—1500 (120V) VGD-700—1500 (230V)
SNMP (optional) г — — — SNMP (optional)
at EPO 5 | EPO
p REMOTE PORT — REMOTE PORT
m ...
AX / NETWORK NETWORK.
. — (MODEM г : e pe SURGE PROTECTION
RCE PROTECTION — USB (optional)
po EXT. BAT (optional) pr EXT. BAT (optional)
dl
. UPS OUTPUT
CROUP 1
p CIRCUIT BREAKER = AC INPUT
| o
URS OUTPUT ‚ = IB CIRCUIT BREAKER
1 e я
г ——— —
VGD-2000—3000 (230V)
REMOTE
EPO
SNMP (optional) PORT
TECTION es PROTECTION
USB (optional) $e -
EXT. BAT (optiona) 4 © AC INPUT
CRU
ERDUP 2 nn
FUNCTION :
Application:
Workgroup Server, Departmental Server, Enterprise Server, WEB server, Workstation.
Problems:
Power Failures, Power sags, Power Surges, Under-voltage Electrical Line Noise, Over-Voltage Frequency Variation, Switching
Transient, Harmonic Distortion.
Even when presented with the most severe of these power problems, the Powercom Vanguard series output remains within a
remarkable +/-2% of nominal voltage. It means that your critical system always receives steady and clean power.
In addition, the Powercom Vanguard series transfer to backup mode with no break in power,making it the perfect UPS for
equipment in environment plagued by poor power,
SPECIAL FEATURES :
1. 15 LCD Display:
Easy viewing of UPS status from LCD panel including:
O/P Voltage O/P Load 09 Battery Charge 09
O/P Frequency O/P Watt (W) | Temperature (CO
1/P Voitage O/P VA Bartery Pack Number
1/P Frequency O/P Currency (A) | Rating (VA)
Battery Voltage Back Up Tirme (Min) CPU Version
2. 14 UPS parameter settings:
O/P Voltage Set Manual Bypass Site Fallure Set
1/P Frequency Set Outlet Segment Set Language Selection
1/P Bypass Set Battery Test Generator Option Set
Free Run Set Silence Mode Set RS232 Control
Lae A Barrery Cabinet Set
The load group status can be viewed from the LCD display and can be changed if necessary.
These load segments are usually handled with the UPS management software.
Refer to chapter 5.2 regarding the two load segments that come with each model.
Available from: www.dueltek.com.au
{LINE UPS-Vanguard UPS
Unique Design
e Vanguard rack mount models come in different heights such as 1U, 2U, or 3U to meet different space demands.
e Vanguard rack mount now is available from 700VA up to 10 KVA.
e Vanguard 3U rack mount model is designed to be flexible and able to fit in different spaces.
e The control panel can be adjust 90 around to accommodate the UPS installation direction (vertically or horizontally).
* Remote control panel feature is designed for easy control of the UPS which is placed in the unreachable area.
MED 00 -—
A——É——————
ESM — =] о =
700-1KVA (1U) и
— =
en =
== —
1K-3KVA (2U) AK-5KVA (3U) 6K-10KVA (3U+3U)
VGD-1K.2K.3K RM2U real panel
CIRCUIT BREAKER CIRCUIT BREAKER
TEL/FAX/NETWORK /MODEM SURGE PROTECTION и DUE TEL/FAX/NETWORK/MODEM SURGE PROTECTION
UPS OUTPUT REMOTE PORT
CROUP 2
UPS OUTPUT ea AS , rl
GROUP 1 й
AC INPUT EPO EXT. BAT (орнопа58 (optional) AC t EPO EXT. BAT 1 (optional)
1) Remote control panel feature:
The display panel can be remove from the front panel and attached to the back panel with a cable in order to provide the
wired-remote feature.
2) Display panel is designed to be easy removable.
3) 2 different direction of insertion slots are designed to attached with display panel providing 2 different angles to suit in
different space demands.
4) The Vanguard 3U rack mount can also be tower model after switching the display panel by turning the front panel and put
up the unit to vertical position.
VGD-4K.5K.6K.8K.10K RM panel
,
Software and Communications Options
* USB port (optional) allows UPS to communicate with Windows 98/ME, and XP computers
* RS232 Port (standard) for interface with power management software
* SNMP/Web card (optional) adds direct control and monitoring capabilities in SNMP-based
networks. Ability to monitor UPS status and meters through web browser interface.
* Relay card (optional) adds integration to industrial environment and building management
systems, shutdown for IBM AS/400.
Available from: www.dueltek.com.au
VANGUARD TOWER
Best Power Protection ;
Your Power Solution
Specification
Tower model (with LCD display)
CAPACITY Capacity (VA)
Capacity (W)
INPUT Voltage / Load
Frequency
Voltage (on battery)
Frequency (on battery)
Transfer Time
Overload Recovery
High Efficiency mode (AC to AC)
UPS Design Technology
Output Wave Form
Harmonic distortion
Crest Factor
PROTECTION AND Surge Protection
Overioad Protection
| Short Circuit Protection
Visual Display
LED model)
Visual Display
ma IS
Audible Alarm
(Battery back-up)
NE
Communication
VCD-1500
700VA 1000VA 1500VA 2000VA 3000VA 4000VA 5000VA
490W | 700W | 1050W 1400wW | 2100W | 2800W 3500W
100V, 110V, 115V, 120V, 127V | 208V, 220V, 230V, 240V )
Voltage / Range | Load Capacity Voltage / Range Load Capacity | Voltage / Range Load Capacity
60 ~ 69V | О - 40% 120 ~ 139% 0 ~ 40% | 120 — 139V | 0 ~ 40%
70 ~ 79V | 0 = 70% | 140 ~ 159V | 0 - 70% | 140 — 159V | 0 — 70%
80 — 144V | 0 = 100% 160 ~ 276V 0 ~ 100% 160 ~ 276V 0 ~ 100%
50 / 60 Hz Auto Sensing
100V, 110V, 115V, 120V, 127V / 208V, 220V, 230V, 240V + /-2% (Selectable Output Voltage)
50 / 60 Ну + /-0.5%
0 ms
Auto transfer to UPS
> 95 *
/ Fully digitized microprocessor controlled
Sinewave
< INof THD. at linear load
AD
120V (EEE C62.41) / 230V (EEECE1000-4-5 level 3)
125% for 1 minutes and 150% for 10 seconds
UPS output cut off immediately or input fuse / circuit breaker protection
UPS onigreen), line -mode(green),
battery modelyeliow), bypassiyeliow), fauittred)
Input / output voltage, Input / output frequency,
on-line mode, back up mode, battery capacity, load level
Beep every 5 sec
Continuous beeping sound and LCD display
KS-232 Serial Port and USB
BATTERY Туре | В Sealed, maintenance-free lead acid batteries 0000
DC Voltage (V) Battery 24V / 12V7.2AH | 36V /12V7.2AH | 36V / 12V9AH | 72V/12V7.24H | 72V/ 12V9AH | 120V/ 12V7AH | 120V/ 12V9AH |
(Tower ) x 2 x 3 x 3 x 6 x6 x 10 x 10
| Typica Recharge Time по ОКР = 4 hours
Management _ Self-test. adjustable battery transfer points and alarm settings
Battery Protection Cut off without draining any current when battery is low
Cold Start (DC start) YES
Back Up Time (Tower model) 7 min 7 min 6 min 7 min 6 min 5 min 6 min
Back Up Time (Half Load) 15 min 1Smin | 1Smin | 15min 15 min 15 min 15 min
Input Inlet
Receptacies
Total Receptacies
(UPS +Surge / Surge Only)
Tower Dimensions Inches
mm (nc) Wx D x H
Net Weight kg db)
Tower model
Shipping Weight kg 0b)
NEMA 5-15 (120V) / IEC 320 230V) Hardwire
NEMA 5-15 (120V) / EC 320 (230V) IEC 320
6 (120V)
4 (230%)
2 (120W)
8 (230V)
EC 320 C13*8
IEC 320 C19°2
152 x 420 x 237
(6.0"x 16.5" x 9.39
225 x 420 x 360
(8.9° x 16,5” x 14.2”)
257 x 540 x 440
(10.1 x 21.3" x 17.37
17.1 17.7 33.8 35.6 TM
(37.6) (38.9) (74.4) (78.3) (189.2)
18.9 19.5 36.0 38,0
(41.6) (42.9) (79.2) (83.6)
106.0
(233.2)
0 -40'C / 32 — 104"F
EMC (EMS / EMD
Warranty
Equipment Protection
Policy
Storage Temperature -20 - 50 C / -4- 1272"
Altitude 3,500 meters max
tite Noe “coma
(1 meter from surface)
Relative Humidity 0 ~ 95% humidity, non-condensing
UL 1778. CE
IEC 61000-4, FCC Part 15, CISPA 22
2 vears
Warranty policy may vary depends on region
Available from: www.dueltek.com.au
V LINE UPS-Vanguard UPS
Specification
Tower model (with LCD display)
CAPACITY
SYSTEM
DISPLAY / WARNINC
ENVIRONMENT
Capacity (VA) 6000VA BOOOVA 10000VA 12000VA 15000VA 20000VA
| Capacity W | aoow | seoow | тон | seoow tosoow | 14000w
Voltage / Load 208V, 220V, 230V, 240V
Voltage / Range Load Capacity | Voltage / Range Load Capacity
120 - 139V | 0~ 25%
140 — 159V О - 50% 180 — 276V 0 - 100%
160 - 179V | 0 - 75%
| rrcauanes 50 / 60 Hz Auto Sensing
Voltage (on battery) 100V, 110V, 115V, 120V J 208V, 220V, 230V, 240V + /- 2% Selectable Output Voltage)
Frequency (on battery)
Transfer Tire
Overload Recovery
High Efficiency mode (AC to AL)
UPS Design Technology
Output Wave Form
Harmonic distortion
Crest Factor
| Surge Protection
Overload Protection
Short Circuit Protection
Visual Display (LED model)
Visual Display (LCD model)
Audible Alarm (Battery back-up)
UPS Fault
Communication
50 / 60 Hz +/-0.5%
VE
Auto transfer to UPS
ra '
On-Line / Fully digitized microprocessor controlled
Sinewave
< Mot THOD. at linear load
3:1
IEC6 1000-4-5 level 3
125% for 1 minutes and 150% for 10 seconds (On-line)
130% for 10 seconds and 150% for 1.5 seconds (On-battery)
UPS output cut off immediately or input fuse / circuit breaker protection
UPS ontgreen), line-modetgreen), bartery modetyellow, bypasstyellow), faultired)
Input / output voltage, input / output frequency, on-line mode, back up mode, battery capacity, load level
Beep every 5 sec
Continuous beeping sound and LCD display
RS- 232 Sertal Port and USE
Type Sealed, maintenance-free lead acid batteries
| DC Voltage (V) Battery (Tower ) | 240V/ 12V7.24H | 240V / 12V7.2AH | 240V/ 12V9AH | 240V/ 12V7.2AH | 240V / 12V7.24H | 240V / 12V9AH
x 20 x 20 x 20 x 20 x 2SET x 20 x 25ET x 20 x 2SET
[Typical Recharge Time [ o - TE o
to 90% Full
¡Management Self-test, adjustable battery transfer points and alarm settings
Battery Protection | Cut off without draining any current when battery is low
| Cold Start (DC start) | YES
| Back Up Time (Tower model) About 6 min Full loal / 15min Half load
Input Inet
Receptacles
Tower Dimensions Inches
mean Onch)y W x D x H W/O SOTR
Net Welght kg 0b) W/O ISOTR
Shipping Weight kg (Ib) W/O ISOTR
Tower Dimensions Inches
mminch) WxDxH
Net Weight kg Ob)
Shipping Weight kg (Ib)
257 x 590 x 570
01237224
86.0 (189.2)
106.0 (233.2)
257 x 590 x 700
(1012372767
123.0 (270.6)
145,0 (319.0)
Hardwire
Hardwire
342 x 863 x 905
(13.5 x 34.0 x 35.6)
257 x 690 x 715
(10.1 x 27.7 x 28.17)
E NET |
di5 277x345)
50.0 (176.0) 130.0 (286.0) 175.0 385.0)
151.5 (333.3)
JAZ x 690 x 878
(013542771346
101.5 (223.3) 196.0 (432.3)
342 x 863 x 905
(13.5" x 34.0" x 35.67
3472 x 690 x 715
(13.4" x 27.7 x 28.17)
130,0 (286.0) 180,0 (396.0) 225.0 (495.0)
151.5 (333.3) 201.5 (443.3) 246.5 (542.3)
Safety
EMC (EMS / EMI)
Warranty
Equipment Protection Policy
Operating Temperature | 0 - 40°C / 32 104"F
Storage Temperature „20 = 50°C / ~4 ~ 122°F
Altitude 3,500 meters max
Audible Noise
(1 meter from surface) EEE
Relative Humidity 0 ~ 95% humidity, non-condensing
UL 1778, CE
IEC 61000-4, FCC Part 15, CISPR 22
2 years
Warranty policy may vary depends on region
Available from: www.dueltek.com.au
Best Power Protection
Your Power Solution
VANGUARD RACK MOUNT
Specification
19° rack-mount model VGD-700-RM VGD-1000-RM | VGD-1500-RM VCD-2000-RM _ VCD-3000-RM | VCD-S5000-RM _ VCD-6000-RM
CAPACITY Capacity (VA) 700VA 1000VA 1500VA 2000VA 3000VA 5000VA 6000VA
Capacity (W) | 490W | 700W | 1050W | 1400W | 2100W | 3500W | 4200W
INPUT [voltage / Load | 100v, 110V, 115V, 120V, 127V | | 208v, 2720v, 230v, 240V
| “Voltage / Range m Load Capacity | Voltage / Range | “Load Capacity И Voltage / Range! Load Capacity
| 60 = 69V | 0 - 40% | 120 — 139V | 0 ~ 40% | 120 — 139V | 0 - 40%
70 = 79V | 0 - 70% | 140 — 159V | 0 = 70% | 140 - 159V | 0~ 70%
| 80 — 144V | 0 - 100% | 1650 - 276V | 0 - 100% | 160 ~ 276V | 0 - 100%
Frequency = ===. == 50 / 60 Hz Auto Sensing Е с
Voltage (on battery) 100vV, 110v, 115V, 120vV, 127vV / 208v, 220v, 230v, 240V +/-2% (Selectable Output Voltage)
Frequency (on battery) 50 / 60 Hz +/-0.5%
Transfer Time 0 ms
Overload Recovery Auto transfer to UPS
High EMciency mode (AC to AC) > 95%
UPS Design Technology | On-Line / Fully digitized microprocessor controlled
Output Wave Form Sinewave
Harmonic distortion < IN of THD. at linear load
Crest Factor | o
PROTECTION AND Surge Protection 120V (EEE C62.41) / 230V (IEEEC61000-4-5 level 3)
ALTERING Overload Protection | 125% for 1 minutes and 150% for 10 seconds
UPS output cut off immediately or input fuse / circuit breaker protection
Visual Display UPS ontgreen), hne-mode(tgreen),
(LED model) battery modetyellon), bypassiyeliow), fault(red)
Visual Display Input / output voltage, input / output frequency,
(LCD model) on-line mode, back up mode, battery capacity, load level
Audible Alarm Beep every 5 sec
(Battery back-up)
UPS Fault Continuous beeping sound and LCD display
Communication | RS-232 Serial Port and USES
BATTERY Type Sealed, maintenance -free lead acid batteries
| DC Voltage (V) Battery (1U) | 24V / 6V7.2AH x 4 | None
‘DC Voltage (V) Battery (2U) 24V / 12V7.2AH| 36V / 12V7.2AH | 36V / 12VOAH| 72v / 12V7.2AH| 72V / 12V9AH | None
| x2 | x 3 | x3 | x6 | x6 / _ _
DC Voltage (V) Bartery (6U) | None | 240V / 12V7.2AH x 20
Typical Recharge Time | 4 hours
to 90% Full |
Management Self test, adjustable battery transfer points and alarm settings
Battery Protection | Cut off without draining any current when battery is low
¡Cold Start (DC start) 1 | YES . . |
Back Up Time (Full Load) | AP = 7 ДЦ) = 7 min | AF = 7 mel = 4 min | 6 min 7 min | 6 min | 9 min | 7 min
Back Up Time (Half Load) | 2 15 ти 15 ий) 27 15 туд = 0 | 15 min 15 min | 15 min | 27 min 20 min
Input Intet NEMA 5-15 (120V) / IEC 320 (230V)
Ta a pe | NEMA 5-15 (120V) / IEC 320 (230W)
Total Receptacies 6 (120V) 4 (120V) Hardwire
(UPS + Surge / Surge Only) 4 (230V) 4 (230V)
19” rack-mount 428 x 525 x 44 428 x 597 x 130 (Power Module)
Dimensions Inches mm (16.9" ж 20.7” ж 1.7”) 10 (16.97 x 23.5” x 5.1”) 30
(Inch) Wx Dx HM 428 x 425 x BA 428 x 635 x B4 428 x 597 x 130 (Battery Module)
(16.9” ж 16.7” ж 3.3”) 20 (169° x 25.0" x 3.3") 20 (16.97 x 23.5" x5.17
Net Weight kg (Ib) 1U=15.0(33.0), EA ELA 33.6 34.3 20.0 (44.0) (Power Module)
19° rack-mount 2U=15.4(33.9) 2U=18.7(41.4) (73.9) (83.6) 66.0 (145.2) (Battery Module)
Shipping Weight kg (Ib) 1U=17.7(38.9), 1U=17.7(38.9), 36.7 38.3 24.0 (52.8) (Power Module)
19° rack-mount 2U=17.919.4) 2U=21.6(47.5) (80.7) (84.3) 75.5 (166.1) (Battery Module)
ENVIRONMENT Operating Temperature 0 - 40°C / 32 — 104°F
Storage Temperature -20 = 50" C / -4 — 122"F
Altitude 3,500 meters max
Audible Noise < 40 dBA
(1 meter from surface)
Relative Humidity 0 ~ 95% humidity, non-condensing
CONFORMANCE Safety UL 1778, CE
EMC (EMS / EMI) EC 61000-4, FCC Part 15, CISPR 22
Warranty 2 years
Equipment Protection Warranty policy may vary depends on region
Policy
Available from: www.dueltek.com.au
Y LINE UPS-Vanguard UPS
VANGUARD RACK MOUNT
Specification
19” rack-mount model
CAPACITY
INPUT
PROTECTION AND
FILTERING
CONFORMANCE
| Capacity (VA) |
| Capacity (W)
+
| Voltage / Load
Voitage (on battery)
Frequency (on battery)
Transfer Time
Overload Recovery
High Efcercy mode (NC io AO
UPS Design Technology
Output Wave Form
Harmonic distortion
Crest Factor
¡Surge Protection
VGD-10K-RM VGD-2000-RM VCD-4000-RM VCD-S000-RM | VGD-2K-RMZU+2U5 VCD-3K-RMQU+2U)
BOOOVA |___10000vA 2000VA 4000VA S000VA | 2000VA 3000VA
5600W 7000W 1400W | 2800W 3500W 1400W 2100W
208v, 220v, 230v, 240V
Voltage / Range | Load Capacity Voltage / Range | Load Capacity Voltage / Range Load Capacity
60 - 69V | 0 ~ 40% 120 - 139v 0 ~ 40% 120 — 139V 0 - 25%
70 ~ 79V | 0 - 70% | 140 ~ 159V 0 ~ 70% 140 - 159v 0 ~ 40%
80 - 144V | 0 ~ 100% 160 ~ 276V 0 ~ 100% 160 ~ 179V 0 ~ 75%
50 / 60 Hz Auto Sensing
100\, 110V, 115V, 120V, 127V / 208V, 220V, 230V, 240V + /- 2% (Selectable Output Voltage)
$0 / 60 Hz +/-0.5%
Ll
Auto transfer to UPS
> 95 %
On-Line / Fully digitized microprocessor controlled
Sinewave
< 3% of THD. at near load
3 1
120v (EEE C62.41) / 230V (IEEEC61000-4-5 level 3)
Overioad Protection
| Short Circuit Protection
Visual Desplay
(LED model)
Visual Display
(LCD model)
Audible Alarm
(Battery back-up)
125% for 1 minutes and 150% for 10 seconds
UPS output cut off immediately or input fuse / circuit breaker protection
UPS onigreen), line-mode(green),
battery modetyellow), bypasstyelion), faultired)
Input / output voltage, Input / output frequency,
on-line mode, back up mode, battery capacity, load level
Beep every 5 sec
UPS Fault Continuous beeping sound and LCD display
Communication RS-232 Serial Port and USB
Type Sealed, maintenance-free lead acid batteries
DC Voltage (V) Battery + |240V / 12V7.2AH | 240V / 12V9AH | 48V / L2V9AH [120v 12V7.2AH | 120V / 12V9AH | 72V | 12V7AH 72V / 12V9AH
x 20 x 20 x4 x 10 x 10 x 6 x 6
Typical Recharge Time 4 hours
to 90% Full
Management Self -test, adjustable battery transfer points and alarm settings
Cold Start (DC start) YES
Back Up Time (Full Load) 5 min 6 min | 6 min | 5 min 6 min 7 min 6 min
Back Up Time (Half Load) 12 min 15 min 15 min | 12 min 15 min 15 min 15 min
input Inket
Receptacies
NEMA 5-15 (120V) / ЕС 320 (230V) / Hardwire
NEMA 5-15 (120V) / HEC 320 (230)
Toral Receptacies IEC 320 C13*4 4 (120V) IEC 320 CI3*8 4 (120V)
APS + Surge / Surge Oni) IEC 320 C19*4 Era IEC 320 C19*2 4 (230V)
1T rack-mount Dimensions 428 x 655 x 260 A 428 x 658 x 130 428 x 425 x 84 (2U) (Power Module)
da MA AA A EE (16.9" x 25.97 x 10.77 6U (05.9*19.7 33.020 (16.9° х 25.9” х 5.1”) 30 428 x 425 x 84 (QU) (Battery Module)
Net Weight kg (Ib) 119 27.0 51.0 9.5 (20.9) (Power Module)
197 rack- mount (242) (59.4) (112.2) 22.0 (48.4) (Battery Module)
Shipping Weight kg (Ib) 130 29.5 66.0 11.5 (25.3) (Power Module)
19° rack-mount (286) (64.9) (145.2) 24.0 (52.8) (Battery Module)
Operating Temperature 0 - 40°С / 32 - 104’;
Storage Temperature «~20~50°C/~4~122°F
Altitude 3,500 meters max
Audible Noise < 40 dBA
(1 meter from surface)
Relative Humidity 0 ~ 95% humidity, non-condensing
Safety
EMC (EMS / EMI)
Warranty
Equipment Protection
Policy
UL 1778. CH
IEC 61000-4, FCC Part 15, CISPR 22
2 vears
Warranty policy may vary depends on region
Available from: www.dueltek.com.au