Diverter Valve Series 725

Diverter Valve Series 725
Diverter Valve
Series 725
Series 725
with electric actuator
08.40
Series 725
with manual actuator
Series 725
with pneumatic actuator
1.0 PRODUCT DESCRIPTION
Available Sizes
• 6"/150 mm
Pressure Rating/Maximum Working Pressure
• Up to 1000 psi/6900 kPa
Function
• 3-way diverter valve
Pipe Preparation
• Victaulic Original Groove System (OGS)
Application
• Intended for use in Paste Backfill mining operations
• Exclusively for use with pipe and Victaulic products featuring ends formed with the Victaulic OGS groove profile
Actuation Options
• Manual actuator, hand wheel with limit stop and standard ISO FA14 mounting flange
• Manual actuator with chain wheel
• Multi-turn Electric actuator
• Pneumatic actuator
• SO 5211, FA30 mounting flange, no operator
2.0 CERTIFICATION/LISTINGS
Product designed and manufactured under the Victaulic Quality Management System, as certified by LPCB in
accordance with ISO-9001:2008.
ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT.
System No.
Location
Spec Section
Paragraph
Submitted By
Date
Approved
Date
victaulic.com
08.40 9203 Rev G Updated 03/2016
© 2016 Victaulic Company. All rights reserved.
1
victaulic.com
3.0 SPECIFICATIONS – MATERIAL
Body/Bonnet Coupling and Body: Ductile iron conforming to ASTM A536, grade 65-45-12.
Plug: Ductile iron conforming to ASTM A-536, grade 65-45-12. PPS coating standard.
Body Seal: PTFE
Gasket and O-Rings: (specify choice1)
Grade “T” Nitrile
Nitrile (Orange color code). Temperature range –20°F to +180°F/–29°C to +82°C. Recommended for petroleum
products, air with oil vapors, vegetable and mineral oils within the specified temperature range; except hot, dry air
over +140°F/+60°C and water over +150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES.
1Services
listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should
always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible.
Drive Stem: 17-4 stainless steel.
Bushing: Bronze conforming to C-932.
Mounting Bracket: Structural steel conforming to ASTM A-500, Grade B.
Manual Actuator: Gear operator contains internal stops to prevent damage to the valve. Manual actuator with
chainwheel option available.
Optional: Electric Actuator, Pneumatic Actuator, No Actuator
Plug with 5D Bend Profile
Ductile Iron Body
Gasket
PTFE
ISO Mounting Flange
O-Rings
Operators
08.40 9203 Rev G Updated 03/2016
victaulic.com
© 2016 Victaulic Company. All rights reserved.
2
victaulic.com
4.0 DIMENSIONS
Series 725
B
B
B
B
A
B
A
C
C
C
A
C
C
I
A
I
A
I
I
I
D
D
D
D
H1
E
H2
D
E
H2
H1
H1
E
T
T
U
T
U
G
U
90°
G
90°
90°
J
J
90°
90°
Series 725 with Manual Actuator
Series 725 with Electric Actuator
Dimensions
Weight
Approximate
Actual
(Each)
Nominal Outside
D
D
E
G
H1
H2
I
I
J
T
lb
Size Diameter A
B
C Manual Electric Manual Electric Manual Electric Manual Electric Electric Manual
U
kg
inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches Electric. Gear.
mm
mm
mm mm mm mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm Actuator Operator
6
6.625 28.63 23.25 14.38 30.13 33.25 43.88 10.13 26.75 31.88 14.50 9.63 18.50 7.88
36
1250.0 980.0
150
168.3 727.3 590 363
762
844
1112
255
679
808
367
245
469
200
914
567.0
444.5
A
B
A
B
C
C
I
D
D
H3
H3
J
J
Series 725 with Pneumatic Actuator
Dimensions
Nominal
Size
inches
mm
6
150
Actual
Outside
Diameter
inches
mm
6.625
168.3
A
inches
mm
28.63
727.3
08.40 9203 Rev G Updated 03/2016
victaulic.com
B
inches
mm
23.25
590
D
Pneumatic
inches
mm
30.75
780
C
inches
mm
14.38
363
© 2016 Victaulic Company. All rights reserved.
3
Weight
H3
Pneumatic
inches
mm
40.25
1021
I
Pneumatic
inches
mm
14.50
368
J
Pneumatic
inches
mm
14.38
364
Approximate
(Each)
lb
kg
1250.0
567.0
victaulic.com
5.0 PERFORMANCE
Not applicable - contact Victaulic with any questions.
6.0 NOTIFICATIONS
Not applicable - contact Victaulic with any questions.
7.0 REFERENCE MATERIALS
Valve Numbering System
V 060 725 M 1 1
Class Size
V
060
Style
Operator
725
M – Manual Actuator
E – Electric Actuator
P – Pneumatic
O – Other
Operator Options
O – None
Manual Operators
M – Hand Wheel
N – Chain Wheel
Electrical Voltage
End Prep
1 – OGS Grooved
3 – Other Specify
1 – 480V, 60Hz, 3 phase
2 – 575V, 60 Hz, 3 phase
3 – 380V, 50 Hz, 3 phase
4 – 380V, 60 Hz, 3 phase
5 – 220V, 60 Hz, 3 phase
6 – 400V, 50 Hz, 3 phase
7 – 415V, 50 Hz, 3 phase
05.01: Seal Selection Guide
29.01: Terms and Conditions/Warranty
I-100: Field Installation Handbook
I-725: Series 725 Diverter Valve Installation Manual
User Responsibility for Product Selection and Suitability
Each user bears final responsibility for making a determination as to the suitability of
Victaulic products for a particular end-use application, in accordance with industry
standards and project specifications, and the applicable building codes and related
regulations as well as Victaulic performance, maintenance, safety, and warning
instructions. Nothing in this or any other document, nor any verbal recommendation,
advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede,
or waive any provision of Victaulic Company's standard conditions of sale, installation
guide, or this disclaimer.
Note
This product shall be manufactured by Victaulic or to Victaulic specifications. All products
to be installed in accordance with current Victaulic installation/assembly instructions.
Victaulic reserves the right to change product specifications, designs and standard
equipment without notice and without incurring obligations.
Installation
Reference should always be made to the Victaulic installation handbook or installation
instructions of the product you are installing. Handbooks are included with each shipment
of Victaulic products, providing complete installation and assembly data, and are available
in PDF format on our website at www.victaulic.com.
Intellectual Property Rights
No statement contained herein concerning a possible or suggested use of any material,
product, service, or design is intended, or should be constructed, to grant any license
under any patent or other intellectual property right of Victaulic or any of its subsidiaries
or affiliates covering such use or design, or as a recommendation for the use of such
material, product, service, or design in the infringement of any patent or other intellectual
property right. The terms “Patented” or “Patent Pending” refer to design or utility patents
or patent applications for articles and/or methods of use in the United States and/or other
countries.
08.40 9203 Rev G Updated 03/2016
victaulic.com
Warranty
Refer to the Warranty section of the current Price List or contact Victaulic for details.
Trademarks
Victaulic and all other Victaulic marks are the trademarks or registered trademarks of
Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries.
© 2016 Victaulic Company. All rights reserved.
4