Signature Module Installation Instructions
US Patent #8,769,878
Models SM-101 and SM-102
SM-101 - T3 (DC) Edges SM-102 T2 (10K0) Edges
WARNING – To reduce the risk of severe injury or death:
Parts List:
• Signature Module (SM)
• Wire Nuts (4)
• Instruction Manual (1)
• Junction Box (1)
1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS
2. Disconnect all power before beginning any work.
3. Do not reconnect the opener to source of power until instructed to do so.
4. Test the system when installation is completed.
5. Follow all local and national electrical codes.
See Step - By - Step Installation Guide on Reverse Side
Figure A.
Figure B.
Sectional Door
Rolling Steel Door
Wiring Diagram for
UL LISTED Operators
UL Listed
Operator
Edge Lead Wire
in Conduit
eeeeeeeeeeeeeeeeeeeeee
eeeeeeeeeeeeeeeeeeeeeeeeeeeeee
Red Wire
Junction Box
Terminated
Sensing Edge
Lead Wire into
Junction Box
Termination
Green LED
Black Wire
To Operator
Photo Eye
Terminals
To Photo Eye
INPUT
MillerEdge
SM-101
EDGE
PWR
ON = Obstruction
BLINKING = Fault
To EDGE
Junction
Box
Red Wire
Red LED
White Wire
Edge Lead
Wire
LED INDICATORS
Green LED ON: Power
Green LED OFF: No Power
Red LED OFF: Edge is NOT Active
Red LED ON: Edge is Active, Fault
Red LED Blinking: Edge is Open
*Termination may be made by Resistor, Diode, Capacitor
or any combination.
MILLER EDGE, INC. • P.O. Box 159 • West Grove, PA 19390 • (610)869-4422 • Fax: (610)869-4423 • 800-220-3343 • www.milleredge.com
MILLER EDGE, INC. • 6809 South Harl Avenue • Suite A • Tempe, AZ 85283 • (480)755-3565 • Fax: (480)755-3558 • 800-887-3343
SM101-SM102_Inst_20140822_Signature Module #3 8/29/14 11:16 AM Page 2
STEP-BY-STEP INSTALLATION GUIDE
1- Mount the Sensing Edge as per the edge installation instructions.
2- Place the Signature Module inside the UL Listed operator.
3- Connect the Black & White wires from the Sensing Edge to the Black
& White wires of the Signature Module. 4- Connect the RED wires from the Signature Module to the Operator. 1
TEST SYSTEM
1- Reapply power to the operator.
2- The RED LED on the Signature Module should be OFF if the safety edge is not active.
3- Open the door slightly.
4- Apply pressure to the Safety Edge, the RED LED on the Signature Module should go ON.
5- Door should open.
* If any steps fail, check all connections.
TROUBLE SHOOTING TIPS
LED Color
GREEN
RED
STATUS
DIAGNOSIS
CAUSE / SOLUTION
ON
Power
Normal Operation
OFF
Edge is Not Active
Normal Operation
BLINKING
Edge is Open, Fault
OFF
ON
No Power
Edge is Active, Fault
Check the wire connection between the
Operator and the Signature Module.
Edge is hit
Check the wire connection between the
Edge and the Signature Module.
Edge is faulty or not proper for this
application
Note 1 : All interconnecting wiring between the Signature Module and the operator is required to be Listed Power-Limited
Circuit Cable Type CL2, CL2P, CL2R, or CL2X depending on the application as described in article 725 of ANSI/NFPA 70,
“National Electric Code” (NEC) in accordance with UL325.
SM101-SM102_Inst_20140822
MILLER EDGE, INC. • P.O. Box 159 • West Grove, PA 19390 • (610)869-4422 • Fax: (610)869-4423 • 800-220-3343 • www.milleredge.com
MILLER EDGE, INC. • 6809 South Harl Avenue • Suite A • Tempe, AZ 85283 • (480)755-3565 • Fax: (480)755-3558 • 800-887-3343
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising