HIGH PRECISION LCR METER

HIGH PRECISION LCR METER
HIGH PRECISION LCR METER
The LCR-800 Series is a high-class digital LCR meter for component/material measurements, applicable
to various R&D activities and production lines. A large 240x128 dot Matrix LCD display gives room for
two measurement items plus setup parameters, and lets users get the whole picture in an instant.
Measurement result is always accompanied with supplement factor as in R/Q, C/D, C/R, and L/Q. The
LCR-821 also contains more accurate resistance measurement as a combination of absolute value and
phase angle. 100 sets of measurement setup memory allow sharing LCR-800 series among multiple
testing conditions or sites. For a better viewing experience with standard PC monitor, Windows based
proprietary software is accessible via RS-232C terminal. The handler interface is standard for
LCR-826/827/829 models.
LCR-821 (12Hz~200kHz)
LCR-819/829 (12Hz~100kHz)
LCR-817/827 (12Hz~10kHz)
LCR-816/826(100Hz~2kHz)
Handler
FEATURES
* Test Frequency:
12Hz~200kHz (LCR-821)
12Hz~100kHz (LCR-819/829)
12Hz~10kHz (LCR-817/827)
100Hz~2kHz (LCR-816/826)
Continuously Variable Frequencies
* 0.05~0.1% Measurement Accuracy
* 100 Sets Memory for Save/Recall of Setup State
* R/Q, C/D, C/R, L/Q Test Modes for all Models;
Z/ , L/R for LCR-821 Only
* Absolute Value, Value, and % Measurement
Display
* 240 x 128 dot Matrix LCD Display
* Test Condition and Test Result Shown on the
Screen Simultaneously
* Interface : RS-232C , Handler
SPECIFICATIONS
TEST FREQUENCY
BASIC ACCURACY
TEST SPEED
TEST SIGNAL LEVELS
DC BIAS
Internal
External
DISPLAY RANGE
Resistance
Capacitance
Inductance
Quality Factor
Dissipation Factor
Impedance
Phase Angle ( Degree )
TEST MODE
EQUIVALENT CIRCUIT
MEMORY
AVERAGE
TEST SPEED MODE
DISPLAY MODE
DISPLAY
INTERFACE
12Hz ~ 200kHz (504 steps) for LCR-821
12Hz ~ 100kHz(503 steps) for LCR-819/829
12Hz ~ 10kHz(489 steps) for LCR-817/827
100Hz ~2kHz (245 steps) for LCR-816/826
0.05% for basic accuracy for LCR-821/819/817
0.1% for basic accuracy for LCR-829/827/826/816
68ms for LCR-821/819/817/816, 34ms for LCR-829/827/826
5mV ~ 1.275Vrms ( 5mV/step ) for LCR-821/819/829/817/827
0.1V ~ 1.275Vrms ( 5mV/step )for LCR-816/826
2V
0 ~ 35V for LCR-821; 0 ~ 30V for LCR-819/829/817/827/816/826
R
C
L
Q
D
Z
0 .00001 ~ 99999k
0.00001pF ~ 99999 F
0.00001mH ~ 99999H
0.0001 ~ 9999
0.0001 ~ 9999
0.00001 ~ 99999k for LCR-821
-180.00 ~ 180.00 for LCR-821
R/Q , C/D, C/R, L/Q
Z/ , L/R for LCR-821 only
Parallel or Serial selectable
100 memory blocks totally
1 to 255 times
SLOW, MEDIUM and FAST
Value,
,
%
240x128 dot matrix C.C.F.L back light LCD
Standard Interface : RS-232C for LCR-821
Standard Interface : Handler Interface for LCR-829/827/826
Optional : RS-232C Interface for LCR-819/817/816 (factory installed)
(Including LCR-Viewer Software)
POWER SOURCE
AC 100V ~ 240V , 50/60Hz
ACCESSORIES
User manual x 1, Power cord x1, LCR-06A x 1
DIMENSIONS & WEIGHT
330 (W) x 149 (H) x 437 (D)mm, Approx. 5.5kg
E13
Rear Panel
LCR-819
ORDERING INFORMATION
LCR-821
LCR-819
LCR-829
LCR-817
LCR-827
LCR-816
LCR-826
200kHz High Precision LCR Meter
100kHz High Precision LCR Meter
100kHz High Precision LCR Meter with Handler Interface
10kHz High Precision LCR Meter
10kHz High Precision LCR Meter with Handler Interface
2kHz High Precision LCR Meter
2kHz High Precision LCR Meter with Handler Interface
Optional Accessories
LCR-05 Test Fixture for Axial & Radial Leaded Components
LCR-07 Test Fixture, Two-Wire with Alligator Clips
LCR-08 Test Fixture(Tweezers) for SMD/Chip Components
LCR-09 Test Fixture for SMD/Chip Components
GRA-402 Rack Adapter Panel, Rack Mounting (19", 4U)
GTL-232 RS232C Cable, 9-pin Female to 9-pin, null Modem for Computer
LCR-800 SERIES SELECTION GUIDE
MODEL
LCR-821
LCR-819
LCR-829
Display
240 x 128 dot matrix CCFL back light LCD
Test Frequency
12Hz~200kHz
(504 steps)
Basic Accuracy
0.05%
12Hz~100kHz
(503 steps)
0.05%
Test Mode
R/Q, C/D, C/R
L/Q, Z/ , L/R
Memory
100 memory blocks totally
DC BIAS
Interface
Internal
2V
External
0 ~35V
RS-232
Std.
Handler
0.1%
R/Q, C/D, C/R,L/Q
LCR-817
LCR-827
12Hz~10kHz
(489 steps)
0.05%
LCR-816
R/Q, C/D, C/R,L/Q
0.1%
R/Q, C/D, C/R,L/Q
2V
2V
2V
0 ~30V
0 ~30V
0 ~30V
Opt.
Opt.
Std.
LCR-05
Description:
Kelvin clip test leads.
Frequency: DC to 200kHz
Max. Voltage: +/- 35V
Description:
Test fixture for measurement
of both axial and vertical
lead components
Frequency: DC to 200kHz
Max. Voltage: +/- 35V
LCR-07
LCR-08
Description:
Test leads for conventional
component measurement.
It is especially useful for high
impedance measurement.
(With alligator clips)
Two-wire measurement;
apply to low C or high R.
Frequency: DC to 200kHz
Max. Voltage: +/- 35V
Description:
SMD / clip tweezers
Frequency: DC to 200kHz
Max. Voltage: +/- 35V
Patent:188540
LCR-09
Patent:186171
Opt.
Std.
Patent:185538
LCR-826
100Hz~2kHz
(245 steps)
0.1%
LCR-06 A
Description:
SMD / chip test fixture
Frequency: DC to 200kHz
Max. Voltage: +/- 35V
Std.
Made to Measure.
Good Will Instrument Co., Ltd.
E14
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF