TECHNICAL SPECIFICATION
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P400
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P400
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
280/350
320/400
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
505.1
Dimension(L*W*H) (mm)
3300X1140X1956
Weight(kg)
3300
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
2306C-E14TAG2 (UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
353
Turbocharged
137X165
201(in full load)
14.6
438
32.2
79.1
461℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
68
47
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤92dBA(open)
ALTERNATOR
ALTERNATOR MODEL
LSA 47.2VS2(Leroy Somer)
Excitation
Brushless
Insulation class
H
Protection class
IP22
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P450
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P450
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
320/400
360/450
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
577.4
Dimension(L*W*H) (mm)
3300X1140X1956
Weight(kg)
3300
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
2306C-E14TAG3 (UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
396
Turbocharged
137X165
199(in full load)
14.6
438
34.6
86.6
474℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
68
47
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤92dBA(open)
ALTERNATOR
ALTERNATOR MODEL
LSA 47.2S4(Leroy Somer)
Excitation
Brushless
Insulation class
H
Protection class
IP22
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P500
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P500
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
360/450
400/500
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
649.5
Dimension(L*W*H) (mm)
3430X1167X1956
Weight(kg)
3800
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
2806C-E16TAG1 ( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
445
Turbocharged
140X171
205 (in full Load)
15.8
540
38
83
457℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
68
50
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤95dBA
ALTERNATOR
ALTERNATOR MODEL
LSA 47.2S5(Leroy Somer)
Excitation
Brushless
Insulation class
H
Protection class
IP22
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P550
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P550
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
400/500
440/550
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
721.7
Dimension(L*W*H) (mm)
3500X1167X1956
Weight(kg)
3940
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
2806C-E16TAG2 ( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
483
Turbocharged
140X171
203 (in full Load)
15.8
540
41.3
90
459℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
68
50
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤95dBA
ALTERNATOR
ALTERNATOR MODEL
LSA 47.2M7(Leroy Somer)
Excitation
Brushless
Insulation class
H
Protection class
IP22
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P625
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P625
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
440/550
500/625
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
793.9
Dimension(L*W*H) (mm)
3245X1460X2197
Weight(kg)
3940
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
2806C-E18TAG1 ( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
561
Turbocharged
145X183
217.7 (in full Load)
18.1
702
45
129
570℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
55.5
61
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤95dBA
ALTERNATOR
ALTERNATOR MODEL
LSA 47.2M8(Leroy Somer)
Excitation
Brushless
Insulation class
H
Protection class
IP22
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P690
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P690
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
500/625
550/690
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
902.1
Dimension(L*W*H) (mm)
3245X1460X2197
Weight(kg)
4706
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
2806C-E18TAG2( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
607
Turbocharged
145X183
202.4 (in full Load)
18.1
702
43
123
563℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
55.5
61
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤95dBA
ALTERNATOR
ALTERNATOR MODEL
LSA 47.2L9(Leroy Somer)
Excitation
Brushless
Insulation class
H
Protection class
IP22
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P725
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P725
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
520/650
580/725
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
938.2
Dimension(L*W*H) (mm)
4140*1700*2150
Weight(kg)
4706
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
4006-23TAG1A ( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
646
Turbocharged
160X190
203 (in full load)
22.92
1200
64
171
410℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
113.4
105
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤95dBA(open)
ALTERNATOR
ALTERNATOR MODEL
LSA 49.1S4 (Leroy Somer)
Excitation
Brushless
Insulation class
H
Protection class
IP23
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P800
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P800
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
580/725
640/800
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
1046.5
Dimension(L*W*H) (mm)
4200*1700*2150
Weight(kg)
4706
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
4006-23TAG2A ( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
711
Turbocharged
160X190
203 (in full load)
22.92
1200
71
180
430℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
113.4
105
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤95dBA(open)
ALTERNATOR
ALTERNATOR MODEL
LSA 49.1M6 (Leroy Somer)
Excitation
Brushless
Insulation class
H
Protection class
IP23
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P900
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P900
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
640/800
720/900
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
1154.7
Dimension(L*W*H) (mm)
4200*1700*2150
Weight(kg)
4706
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
4006-23TAG3A ( UK Perkins)
Water-cooled, 6 cylinders in line, 4-cycle, direct injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
786
Turbocharged
160X190
203 (in full load)
22.92
1200
73
193
500℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
113.4
105
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤95dBA(open)
ALTERNATOR
ALTERNATOR MODEL
LSA 49.1M75 (Leroy Somer)
Excitation
Brushless
Insulation class
H
Protection class
IP23
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1100
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P1100
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
800/1023
880/1100
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
1476.6
Dimension(L*W*H) (mm)
4750*1870*2360
Weight(kg)
7611
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
4008-TAG2A ( UK Perkins)
Water-cooled, 8 cylinders in line, 4-cycle, direct injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
985
Turbocharged
160X190
214 (in full load)
30.56
1110
80.5
200
465℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
149
153
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤102dBA(open)
ALTERNATOR
ALTERNATOR MODEL
LSG55(Leroy Somer)
Excitation
Brushless
Insulation class
H
Protection class
IP23
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1375
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P1375
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
1000/1250
1100/1375
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
1804.3
Dimension(L*W*H) (mm)
4800*1870*2570
Weight(kg)
9154
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
4012TWG2( UK Perkins)
Water-cooled, 12 cylinders V-line, 4-cycle, direct
injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Engine coolant flow l/s
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
1207
Turbocharged
160X190
207 (in full load)
45.84
15.7
97
245
460℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
205
159
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤102dBA(open)
ALTERNATOR
ALTERNATOR MODEL
LVI634G(Stamford)
Excitation
Brushless
Insulation class
H
Protection class
IP22
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1550
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P1550
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
1100/1375
1240/1550
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
1984.7
Dimension(L*W*H) (mm)
5600*2250*2570
Weight(kg)
11580
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
4012TAG1A( UK Perkins)
Water-cooled, 12 cylinders V-line, 4-cycle, direct
injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Engine coolant flow(l/s)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
1292
Turbocharged
160X190
203 (in full load)
45.84
17
108
270
490℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
159
235
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤102dBA(open)
ALTERNATOR
ALTERNATOR MODEL
PI734B(Stamford)
Excitation
Brushless
Insulation class
H
Protection class
IP22
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1650
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P1650
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
1200/1500
1320/1650
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
2165.1
Dimension(L*W*H) (mm)
5927*2300*3010
Weight(kg)
15430
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
4012TAG2A( UK Perkins)
Water-cooled, 12 cylinders V-line, 4-cycle, direct
injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Engine coolant flow(l/s)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
1386
Turbocharged
160X190
206 (in full load)
45.84
17
110
290
510℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
159
235
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤102dBA(open)
ALTERNATOR
ALTERNATOR MODEL
PI734C(Stamford)
Excitation
Brushless
Insulation class
H
Protection class
IP22
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1850
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P1850
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
1320/1650
1452/1815
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
2381.6
Dimension(L*W*H) (mm)
5927*2300*3010
Weight(kg)
15430
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
4016TAG ( UK Perkins)
Water-cooled, 16 cylinders V-line, 4-cycle, direct
injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Exhaust air flow(m3/min)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
1649
Turbocharged
160X190
206 (in full load)
61.12
1916
146
379
480℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
215
300
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤102dBA(open)
ALTERNATOR
ALTERNATOR MODEL
PI734D(Stamford)
Excitation
Brushless
Insulation class
H
Protection class
IP22
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2
M SERIES PERKINS DIESEL GENERATING SETS
TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P2250
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and it’s system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.
MAIN SPECIFICATIONS OF GENERATOR SETS
Diesel Generator Set
GENSET MODEL NOS.
M-P2250
Rated speed / frequency
Continuous output(KW/KVA)
Standby output(KW/KVA)
Voltage, Phase and wire
1500 rpm / 50 Hz
1640/2050
1800/2250
400V/230V, 3 Phase and 4 Wires
Rated power factor
0.8(lagging)
Maximum output current(A)
2959
Dimension(L*W*H) (mm)
6011*2280*3010
Weight(kg)
15500
Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL
Engine Characters
4016TAG2A( UK Perkins)
Water-cooled, 16 cylinders V-line, 4-cycle, direct
injection
The maximum output(kW)
Aspiration
Bore(mm)×Stroke (mm)
Fuel consumption(g/kw.h)
Cubic Capacity (Liters)
Engine coolant flow(l/s)
Compress air flow(m3/min)
Exhaust gas flow(m3/min)
Exhaust highest temperature
1890
Turbocharged
160X190
212(in full load)
61.1
19
145
393
493℃
1
M SERIES PERKINS DIESEL GENERATING SETS
Lub-oil pan capacity(L)
Cooling water capacity(L)
214
316
Voltage for start(V)
24
Instrument for adjusting speed
Electronically
Noise level(@7M)
≤102dBA(open)
ALTERNATOR
ALTERNATOR MODEL
PI734F(Stamford)
Excitation
Brushless
Insulation class
H
Protection class
IP22
Efficiency
91.5%
Steady state voltage regulation
≤±0.5%
Voltage Control
AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
☺ Start/Stop button
☺ Hour run meter
☺ Monitor engine temperature and provides shutdown protection
☺ Monitor engine speed and provides optional shutdown protection
☺ Monitor oil pressure or level and provides shutdown protection
☺ Alarm output for abnormal operation
Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.
In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.
2