AS09..S ... AS16..S 3-pole contactors
4 to 7.5 kW
AC operated - with spring terminals
1SBC101009F0014
Description
AS09-30-10S
AS09 ... AS16 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and
220 V DC.
These contactors are of the block type design with:
–– spring terminals
–– 3 main poles and 1 built-in auxiliary contact
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
20
5.5
7.5
22
22
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc
rating
(1)
600 V AC
hp
5
A
12
7.5
12
10
15.2
V 50 Hz
V 60 Hz
24
24
-
120
230
230
400
400
24
24
-
120
230
230
400
400
24
24
-
120
230
230
400
400
Auxiliary Type
contacts
fitted
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Order code
Weight
Pkg
(1 pce)
AS09-30-10S-20
AS09-30-01S-20
AS09-30-10S-16
AS09-30-01S-16
AS09-30-10S-26
AS09-30-01S-26
AS09-30-10S-28
AS09-30-01S-28
AS12-30-10S-20
AS12-30-01S-20
AS12-30-10S-16
AS12-30-01S-16
AS12-30-10S-26
AS12-30-01S-26
AS12-30-10S-28
AS12-30-01S-28
AS16-30-10S-20
AS16-30-01S-20
AS16-30-10S-16
AS16-30-01S-16
AS16-30-10S-26
AS16-30-01S-26
AS16-30-10S-28
AS16-30-01S-28
1SBL101004R2010
1SBL101004R2001
1SBL101004R1610
1SBL101004R1601
1SBL101004R2610
1SBL101004R2601
1SBL101004R2810
1SBL101004R2801
1SBL111004R2010
1SBL111004R2001
1SBL111004R1610
1SBL111004R1601
1SBL111004R2610
1SBL111004R2601
1SBL111004R2810
1SBL111004R2801
1SBL121004R2010
1SBL121004R2001
1SBL121004R1610
1SBL121004R1601
1SBL121004R2610
1SBL121004R2601
1SBL121004R2810
1SBL121004R2801
kg
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
mm, inches
72.5 2.85"
2x
M4 8-32 UNC
35 1.38"
ø 4.2 0.17"
50 1.97"
5.5 0.22"
10 0.39"
60 2.36"
7 0.28"
35 mm EN/IEC 60715
68 2.68"
45 1.77"
AS09..S, AS12..S, AS16..S
4 | ABB
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
1SBC101454S0201
Main dimensions
ASL09..S ... ASL16..S 3-pole contactors
4 to 7.5 kW
DC operated - with spring terminals
1SBC101011F0014
Description
ASL09-30-10S
ASL09..S ... ASL16..S contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC and 220 V DC.
These contactors are of the block type design with:
–– spring terminals
–– 3 main poles and 1 built-in auxiliary contact
–– control circuit: low consumption (3 W at pull-in and holding) DC operated with solid core magnet. Suitable for
direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected)
–– add-on auxiliary contact blocks for front mounting and comprehensive range of accessories.
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
20
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc
rating
(1)
600 V AC
hp
5
A
12
V DC
24
48
110
220
5.5
22
7.5
12
24
48
110
220
7.5
22
10
15.2
24
48
110
220
Auxiliary Type
contacts
fitted
Order code
Weight
Pkg
(1 pce)
kg
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
ASL09-30-10S-81
ASL09-30-01S-81
ASL09-30-10S-83
ASL09-30-01S-83
ASL09-30-10S-86
ASL09-30-01S-86
ASL09-30-10S-88
ASL09-30-01S-88
ASL12-30-10S-81
ASL12-30-01S-81
ASL12-30-10S-83
ASL12-30-01S-83
ASL12-30-10S-86
ASL12-30-01S-86
ASL12-30-10S-88
ASL12-30-01S-88
ASL16-30-10S-81
ASL16-30-01S-81
ASL16-30-10S-83
ASL16-30-01S-83
ASL16-30-10S-86
ASL16-30-01S-86
ASL16-30-10S-88
ASL16-30-01S-88
1SBL103004R8110
1SBL103004R8101
1SBL103004R8310
1SBL103004R8301
1SBL103004R8610
1SBL103004R8601
1SBL103004R8810
1SBL103004R8801
1SBL113004R8110
1SBL113004R8101
1SBL113004R8310
1SBL113004R8301
1SBL113004R8610
1SBL113004R8601
1SBL113004R8810
1SBL113004R8801
1SBL123004R8110
1SBL123004R8101
1SBL123004R8310
1SBL123004R8301
1SBL123004R8610
1SBL123004R8601
1SBL123004R8810
1SBL123004R8801
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
mm, inches
72.5 2.85"
5.5 0.22"
10 0.39"
2x
M4 8-32 UNC
35 1.38"
ø 4.2 0.17"
60 2.36"
7 0.28"
35 mm EN/IEC 60715
68 2.68"
45 1.77"
1SBC101455S0201
Main dimensions
ASL09..S, ASL12..S, ASL16..S
ABB | 5
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
AS09..S ... AS16..S 2-stack 3-pole contactors
4 to 7.5 kW
AC operated - with spring terminals
1SBC101333F0014
Description
AS09-30-32S
AS09..S ... AS16..S contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC
and 220 V DC.
These contactors are of the block type design with:
–– spring terminals
–– 1st stack with 3 main poles and 1 N.O. built-in auxiliary contact
–– 2nd stack with permanently fixed 2 N.O. + 2 N.C. auxiliary contact block
–– the auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are
mirror contacts
–– control circuit: AC operated
–– a comprehensive range of accessories.
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
20
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc
rating
(1)
600 V AC
hp
5
A
12
5.5
22
7.5
12
7.5
22
10
15.2
V 50 Hz
V 60 Hz
24
230
400
24
230
400
24
230
400
24
120
230
400
24
120
230
400
24
120
230
400
Auxiliary Type
contacts
fitted
3
3
3
3
3
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
AS09-30-32S-20
AS09-30-32S-16
AS09-30-32S-26
AS09-30-32S-28
AS12-30-32S-20
AS12-30-32S-16
AS12-30-32S-26
AS12-30-32S-28
AS16-30-32S-20
AS16-30-32S-16
AS16-30-32S-26
AS16-30-32S-28
Order code
Weight
Pkg
(1 pce)
1SBL101004R2032
1SBL101004R1632
1SBL101004R2632
1SBL101004R2832
1SBL111004R2032
1SBL111004R1632
1SBL111004R2632
1SBL111004R2832
1SBL121004R2032
1SBL121004R1632
1SBL121004R2632
1SBL121004R2832
kg
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
Main dimensions
mm, inches
110.8 4.36"
72.5 2.85"
45 1.77"
10 0.39"
AS09..S, AS12..S, AS16..S
6 | ABB
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
1SBC101456S0201
5.5 0.22"
35.4 1.39"
35 mm EN/IEC 60715
68 2.68"
7 0.28"
ASL09..S ... ASL16..S 2-stack 3-pole contactors
4 to 7.5 kW
DC operated - with spring terminals
1SBC101335F0014
Description
ASL09-30-32S
ASL09..S ... ASL16..S contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC and 220 V DC.
These contactors are of the block type design with:
–– spring terminals
–– 1st stack with 3 main poles and 1 N.O. built-in auxiliary contact
–– 2nd stack with permanently fixed 2 N.O. + 2 N.C. auxiliary contact block
–– the auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are
mirror contacts
–– control circuit: low consumption (3 W at pull-in and holding) DC operated with solid core magnet. Suitable for
direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected)
–– a comprehensive range of accessories.
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
20
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc
rating
(1)
600 V AC
hp
5
A
12
5.5
22
7.5
12
7.5
22
10
15.2
Auxiliary Type
contacts
fitted
Order code
Weight
Pkg
(1 pce)
kg
V DC
24
48
110
220
24
48
110
220
24
48
110
220
3
3
3
3
3
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
ASL09-30-32S-81
ASL09-30-32S-83
ASL09-30-32S-86
ASL09-30-32S-88
ASL12-30-32S-81
ASL12-30-32S-83
ASL12-30-32S-86
ASL12-30-32S-88
ASL16-30-32S-81
ASL16-30-32S-83
ASL16-30-32S-86
ASL16-30-32S-88
1SBL103004R8132
1SBL103004R8332
1SBL103004R8632
1SBL103004R8832
1SBL113004R8132
1SBL113004R8332
1SBL113004R8632
1SBL113004R8832
1SBL123004R8132
1SBL123004R8332
1SBL123004R8632
1SBL123004R8832
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
Main dimensions
mm, inches
110.8 4.36"
72.5 2.85"
45 1.77"
10 0.39"
1SBC101457S0201
5.5 0.22"
35.4 1.39"
35 mm EN/IEC 60715
68 2.68"
7 0.28"
ASL09..S, ASL12..S, ASL16..S
ABB | 7
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Main accessories
Contactor and main accessories (other accessories available)
VM3
CA3..S
AS..S
ASL..S
Contactors
RV5, RC5-1 or RT5
CA3..S
AS..S
ASL..S
Contactors
Main accessory fitting details
Contactor
types
Main
poles
Built-in
auxiliary
contacts
Front-mounted accessories
Auxiliary contact blocks
Side-mounted accessories
Mechanical
interlock unit
(between 2 contactors)
1-pole CA3..S
AS09..S ... AS16..S
AS09..S ... AS16..S
AS09..S … AS16..S
ASL09..S ... ASL16..S
ASL09..S ... ASL16..S
ASL09..S … ASL16..S
3
3
3
3
3
3
0
0
0
0
0
0
1
0
3
1
0
3
0
1
2
0
1
2
VM3
Surge suppressors
2 max.
+
1
+
RV5
or RC5-1
–
2 max.
+
1
1
+
+
RV5
RV5
or RC5-1
or RT5
1
+
RV5
or RT5
–
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Main accessories
1SBC101037F0014
Front-mounted instantaneous auxiliary contact blocks
For contactors
CA3-10S
Order code
Pkg
qty
Weight
(1 pce)
CA3-10S
CA3-01S
1SBN011019T1010
1SBN011019T1001
10
10
kg
0.011
0.011
For contactors
Type
Order code
Pkg
qty
AS09..S … AS16..S, ASL09..S … ASL16..S
VM3
1SBN031005T1000
10
Weight
(1 pce)
kg
0.002
Type
Order code
Pkg
qty
Weight
(1 pce)
RV5/50
RV5/133
RV5/250
RV5/440
RC5-1/50
RC5-1/133
RC5-1/250
RC5-1/440
RT5/32
RT5/65
RT5/90
RT5/150
RT5/264
1SBN050010R1000
1SBN050010R1001
1SBN050010R1002
1SBN050010R1003
1SBN050100R1000
1SBN050100R1001
1SBN050100R1002
1SBN050100R1003
1SBN050020R1000
1SBN050020R1001
1SBN050020R1002
1SBN050020R1003
1SBN050020R1004
2
2
2
2
2
2
2
2
2
2
2
2
2
kg
0.015
0.015
0.015
0.015
0.012
0.012
0.012
0.012
0.015
0.015
0.015
0.015
0.015
Order code
Pkg
qty
1SBN081020R1000
1
1
0
1SBC101069F0014
AS09..S … AS16..S
ASL09..S … ASL16..S
0
1
Mechanical interlock unit
VM3
1SBC574001F0301
Surge suppressors
For contactors
AS09..S ... AS16..S,
ASL09..S ... ASL16..S
RV5
AS09..S ... AS16..S
Rated control circuit
voltage - Uc
V
24...50
50...133
110...250
250...440
24...50
50...133
110...250
250...440
12...32
25...65
50...90
77...150
150...264
AC
●
●
●
●
●
●
●
●
–
–
–
–
–
DC
●
●
●
●
–
–
–
–
●
●
●
●
●
1SBC101384F0010
ASL09..S ... ASL16..S
BEA16-3U
Auxiliary Type
contacts
Connecting links with manual motor starters
For contactors
Manual motor
starter
Type
AS09..S ... AS16..S
ASL09..S ... ASL16..S
MS116-0.16 ... MS116-16 BEA16-3U
MS132-0.16 ... MS132-16
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Weight
(1 pce)
kg
0.045
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Technical data
Main pole - Utilization characteristics according to IEC
Contactor types
AS09..S
AS12..S
ASL09..S
ASL12..S
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
690 V
50 / 60 Hz
AS16..S
ASL16..S
20 A
2.5 mm²
22 A
2.5 mm²
22 A
2.5 mm²
20 A
15 A
12 A
2.5 mm²
22 A
17 A
14 A
22 A
17 A
14 A
220-230-240 V
400 V
415 V
440 V
500 V
690 V
9 A
9 A
9 A
8 A
8 A
5 A
12 A
12 A
12 A
11 A
11 A
7 A
15.7 A
15.5 A
15.5 A
13.6 A
12.5 A
9 A
220-230-240 V
400 V
415 V
440 V
500 V
690 V
2.2 kW
3 kW
4 kW
5.5 kW
4 kW
5.5 kW
4 kW
5.5 kW
4 kW
5.5 kW
4 kW
5.5 kW
10 x Ie AC-3 acc. to IEC 60947-4-1
8 x Ie AC-3 acc. to IEC 60947-4-1
4 kW
7.5 kW
7.5 kW
7.5 kW
7.5 kW
7.5 kW
12 A
5.5 kW
16 A
7.5 kW
22 A
11 kW
250 A
124 A
75 A
55 A
22 A
250 A
124 A
75 A
55 A
22 A
1.1 W
0.33 W
1.1 W
0.55 W
AC operated
DC operated
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
With conductor cross-sectional area
AC-1 Utilization category
For air temperature close to contactor
Ie / Rated operational current AC-1
Ue max. ≤ 690 V, 50/60 Hz
θ ≤ 40 °C
θ ≤ 60 °C
θ ≤ 70 °C
With conductor cross-sectional area
AC-3 Utilization category
For air temperature close to contactor θ ≤ 60 °C
Ie / Max. rated operational current AC-3 (1)
M
3
3-phase motors
Rated operational power AC-3 (1)
M
3
1500 r.p.m. 50 Hz
1800 r.p.m. 60 Hz
3-phase motors
Rated making capacity AC-3
Rated breaking capacity AC-3
AC-8a Utilization category
(without thermal overload relay - Ue 400 V 50/60 Hz - θ ≤ 40 °C)
Ie / Rated operational current AC-8a
Rated operational power AC-8a
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded (2)
Ue ≤ 500 V AC - gG type fuse
Rated short-time withstand current Icw
at 40 °C ambient temperature,
in free air from a cold state
Maximum breaking capacity
cos φ = 0.45
Power dissipation per pole
Max. electrical switching frequency
25 A
230 A
100 A
65 A
1 min 50 A
15 min 20 A
1 s
10 s
30 s
at 440 V
at 690 V
Ie / AC-1
Ie / AC-3
AC-1
AC-3
AC-4
155 A
90 A
0.9 W
0.18 W
600 cycles/h
1200 cycles/h
300 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
1SBC101490S0201
(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".
10 | ABB
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Technical data
Main pole - Utilization characteristics according to UL / NEMA / CSA
Contactor types
AC operated
DC operated
Standards
Max. operational voltage
NEMA size
Thermal current
NEMA continuous amp rating
115 V AC
NEMA maximum horse power ratings 1-phase, 60 Hz
NEMA maximum horse power ratings 3-phase, 60 Hz
UL / CSA General use rating
600 V AC
With conductor cross-sectional area
UL / CSA maximum 1-phase motor rating
Full load current
Horse power rating
UL / CSA maximum 3-phase motor rating
Full load current (1)
Horse power rating (1)
230 V AC
200 V AC
230 V AC
460 V AC
575 V AC
120 V AC
240 V AC
120 V AC
240 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
AS09..S
ASL09..S
UL 508, CSA C22.2 N°14
690 V
00
9 A
1/3 hp
1 hp
1-1/2 hp
1-1/2 hp
2 hp
2 hp
AS12..S
ASL12..S
AS16..S
ASL16..S
00
00
1/3 hp
1 hp
1-1/2 hp
1-1/2 hp
2 hp
2 hp
1/3 hp
1 hp
1-1/2 hp
1-1/2 hp
2 hp
2 hp
12 A
AWG 14
12 A
AWG 14
15.2 A
AWG 12
7.2 A
8 A
1/3 hp
1 hp
9.8 A
10 A
1/2 hp
1-1/2 hp
13.8 A
12 A
3/4 hp
2 hp
7.8 A
6.8 A
7.6 A
9 A
2 hp
2 hp
5 hp
7-1/2 hp
7.8 A
9.6 A
11 A
11 A
2 hp
3 hp
7-1/2 hp
10 hp
11 A
15.2 A
14 A
11 A
3 hp
5 hp
10 hp
10 hp
40 A
J
50 A
60 A
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
Fuse rating
Fuse type, 600 V
Max. electrical switching frequency
For general use
For motor use
600 cycles/h
1200 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
General technical data
AC operated
DC operated
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Ambient air temperature close to contactor
Operation
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
C1
A
A
B1
B2
C2
Vibration withstand acc. to IEC 60068-2-6
AS09..S
ASL09..S
AS12..S
ASL12..S
AS16..S
ASL16..S
690 V
600 V
6 kV
-40...+70 °C
-60...+80 °C
Category B according to IEC 60947-1 Annex Q
3000 m
10 millions operating cycles
3600 cycles/h
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
Shock direction
A
B1
B2
C1
C2
AS contactors - AC operated
ASL contactors - DC operated
20 g
20 g
10 g closed position / 5 g open position
15 g
15 g
10 g
20 g closed position / 9 g open position
15 g
20 g closed position / 14 g open position
14 g
5...300 Hz / 3 g closed position / 2 g open position
closed position / 10 g open position
closed position / 5 g open position
1SBC101490S0201
Contactor types
closed position / 8 g open position
closed position / 8 g open position
ABB | 11
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Technical data
Magnet system characteristics for AS09..S … AS16..S contactors
Contactor types
Coil operating limits
AC operated
AS09..S
AS12..S
AS16..S
AC supply
acc. to IEC 60947-4-1
AC control voltage Rated control circuit voltage Uc
at 50 Hz
at 60 Hz
Coil consumption Average pull-in value 50 Hz
60 Hz
50/60 Hz
Average holding value 50 Hz
60 Hz
50/60 Hz
Drop-out voltage
Operating time
Between coil energization and:
Between coil de-energization and:
N.O. contact closing
N.C. contact opening
N.O. contact opening (1)
N.C. contact closing (1)
0.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)
24...415 V
24...415 V
33 VA
33 VA
33 VA
6.5 VA / 1.5 W
5 VA / 1.2 W
6.5 VA / 1.5 W
Approx. 30...50 % of Uc
9...24 ms
6...18 ms
5...19 ms
7...22 ms
(1) The use of RC5-1 surge suppressor increases opening time by a factor of 2 to 3.
Magnet system characteristics for ASL09..S … ASL16..S contactors
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
DC control voltage
Drop-out voltage
Coil time constant
DC operated
ASL09..S
ASL12..S
ASL16..S
DC supply
0.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)
Rated control circuit voltage Uc
12...240 V DC
Average pull-in value 3 W
Coil consumption
Average holding value 3 W
Approx. 10...40 % of Uc
L/R 12 ms
Open
L/R 40 ms
Closed
Operating time
Between coil energization and:
Between coil de-energization and:
N.O. contact closing
N.C. contact opening
N.O. contact opening (1)
N.C. contact closing (1)
36...59 ms
31...53 ms
13...17 ms
15...20 ms
(1) The use of RT5 surge suppressor increases opening time by a factor of 1.1 to 1.2
Mounting characteristics and conditions for use
Contactor types
AC operated
DC operated
AS09..S
ASL09..S
Mounting positions
AS12..S
ASL12..S
Pos. 2
+30°
AS16..S
ASL16..S
-30°
Pos. 4
Pos. 3
Pos. 1
Pos. 5
The contactors can be assembled side by side.
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
1SBC101490S0201
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
Pos. 1 ± 30°
12 | ABB
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Technical data
Connecting characteristics
Contactor types
AC operated
DC operated
AS09..S
ASL09..S
AS12..S
ASL12..S
AS16..S
ASL16..S
Main terminals
Spring terminals
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid
Flexible with non insulated ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL / CSA
Stripping length
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL / CSA
Stripping length
Degree of protection
1x
2x
1x
2x
1x
2x
1 or 2 x
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
0.75...1.5 mm²
AWG 18...12
10 mm
1x
2x
1x
2x
1x
2x
1 or 2 x
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
0.75...1.5 mm²
AWG 18...14
10 mm
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
All terminals
IP20
Flat Ø 3.5
1SBC101490S0201
Screwdriver type
ABB | 13
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Technical data
Built-in auxiliary contacts according to IEC
Contactor types
AC operated
DC operated
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free air thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
24-127 V 50/60 Hz
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
Making capacity AC-15
Breaking capacity AC-15
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
for 1.0 s
for 0.1 s
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Non-overlapping time between N.O. and N.C. contacts
Power dissipation per pole at 6 A
Max. electrical switching frequency
AC-15
DC-13
Mechanically linked contacts
acc. to annex L of IEC 60947-5-1
Mirror contacts
acc. to annex F of IEC 60947-4-1
AS09..S
ASL09..S
690 V
50 / 60 Hz
10 A
AS12..S
ASL12..S
AS16..S
ASL16..S
6 A
4 A
3 A
2 A
2 A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
10 A
100 A
140 A
12 V / 3 m
10-7
1.5 ms
0.1 W
1200 cycles/h
900 cycles/h
Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA3 aux.
contact blocks) are mechanically linked contacts.
Built-in N.C. auxiliary contacts or additional N.C. auxiliary contacts (CA3 aux. contact blocks) are
mirror contacts.
Built-in auxiliary contacts according to UL / CSA
Contactor types
AS09..S
ASL09..S
600 V AC, 250 V DC
A600, Q300
10 A
7200 VA
720 VA
2.5 A
69 VA
AS12..S
ASL12..S
AS16..S
ASL16..S
1SBC101490S0201
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
AC operated
DC operated
14 | ABB
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
AS09..S ... AS16..S 3-pole contactors - with spring terminals
Terminal marking and positioning
AS..S contactors - AC operated
Standard devices without addition of auxiliary contacts
1L1 3L2 5L3 13
1L1 3L2 5L3 21
A1
NO
NC
NO
NC
2T1 4T2 6T3 14
2T1 4T2 6T3 22
A2
AS09 ... AS16-30-10S
1L1 3L2 5L3 13
A1
A1
1L1
3L2
5L3
13
NO
A2
2T1
4T2
6T3
NO
14
A2
AS09 ... AS16-30-01S
AS09 ... AS16-30-10S
A1
1L1
3L2
5L3
21
NC
A2
2T1
4T2
6T3
NC
22
AS09 ... AS16-30-01S
A1
NO
21NC 31NC 43NO 53NO
NC NC NO NO
22NC 32NC 44NO 54NO
NO
2T1 4T2 6T3 14
A1
1L1
3L2
5L3
13
NO
21
NC
31
NC
43
NO
53
NO
A2
2T1
4T2
6T3
NO
14
NC
22
NC
32
NO
44
NO
54
A2
AS09 … AS16-30-32S
AS09 ... AS16-30-32S
Other possible contact combinations with auxiliary contact blocks added by the user
1L1 3L2 5L3 13
1L1 3L2 5L3 13
A1
NO
A1
NO
21
2-
-1
=
NC
22
+
2-
-2
NO
2T1 4T2 6T3 14
2T1 4T2 6T3 14
A2
=
21
33
NO
22
34
1L1 3L2 5L3 13
A1
+
3L2
5L3
13
NO
21
NC
A2
2T1
4T2
6T3
NO
14
NC
22
CA3-01S
Combination 11
A1
NO
2-
3-
-1
=
+
2-
NO
2T1 4T2 6T3 14
1L1
A2
AS09 ... AS16-30-10S
NO
NC
A1
NO
Combination 11
1L1 3L2 5L3 13
NC
3-
NC
-3
+
-2
NO
-4
A1
1L1
3L2
5L3
13
NO
21
NC
33
NO
A2
2T1
4T2
6T3
NO
14
NC
22
NO
34
NO
2T1 4T2 6T3 14
A2
Combination 21
=
A2
AS09 ... AS16-30-10S
+
CA3-01S
+
CA3-10S
Combination 21
CA3..S 1-pole auxiliary contact blocks
-1
-3
-3
NO
-1
NO
NC
-4
-2
-4
CA3-10S
NC
-2
CA3-01S
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Terminal marking and positioning
ASL..S contactors - DC operated (the polarity A1+, A2- must be respected)
Standard devices without addition of auxiliary contacts
1L1 3L2 5L3 13
1L1 3L2 5L3 21
A1+
NO
NC
NO
NC
2T1 4T2 6T3 14
A1+
2T1 4T2 6T3 22
A2-
ASL09 ... ASL16-30-10S
A1+
1L1
3L2
5L3
13
NO
A2-
2T1
4T2
6T3
NO
14
A2-
ASL09 ... ASL16-30-01S
ASL09 ... ASL16-30-10S
A1+
1L1
3L2
5L3
21
NC
A2-
2T1
4T2
6T3
NC
22
ASL09 ... ASL16-30-01S
1L1 3L2 5L3 13 A1+
NO
21NC 31NC 43NO 53NO
NC NC NO NO
22NC 32NC 44NO 54NO
NO
2T1 4T2 6T3 14
A1+
1L1
3L2
5L3
13
NO
21
NC
31
NC
43
NO
53
NO
A2-
2T1
4T2
6T3
NO
14
NC
22
NC
32
NO
44
NO
54
A2-
ASL09 … ASL16-30-32
ASL09 ... ASL16-30-32S
Other possible contact combinations with auxiliary contact blocks added by the user
1L1 3L2 5L3 13
1L1 3L2 5L3 13
A1+
NO
A1+
NO
21
2-
-1
=
NC
22
+
2-
-2
NO
2T1 4T2 6T3 14
=
21
33
NO
22
34
A2-
ASL09 ... ASL16-30-10S + CA3-01S
1L1 3L2 5L3 13
A1+
NO
NC
1L1
3L2
5L3
13
NO
21
NC
A2-
2T1
4T2
6T3
NO
14
NC
22
Combination 11
A1+
NO
2-
3-
-1
=
+
2-
NO
2T1 4T2 6T3 14
A1+
NO
2T1 4T2 6T3 14
A2-
Combination 11
1L1 3L2 5L3 13
NC
3-
NC
-2
-3
+
NO
-4
A1+
1L1
3L2
5L3
13
NO
21
NC
33
NO
A2-
2T1
4T2
6T3
NO
14
NC
22
NO
34
NO
2T1 4T2 6T3 14
A2-
Combination 21
=
A2-
ASL09 ... ASL16-30-10S + CA3-01S + CA3-10S
Combination 21
CA3..S 1-pole auxiliary contact blocks
-1
-3
-3
NO
-1
NO
NC
-4
-2
-4
CA3-10S
NC
-2
CA3-01S
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
AS09..S ... AS16..S 3-pole contactors - with spring terminals
Main dimensions
mm, inches
72.5 2.85"
2x
M4 8-32 UNC
10 0.39"
5.5 0.22"
35 1.38"
ø 4.2 0.17"
50 1.97"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
60 2.36"
45 1.77"
AS09..S, AS12..S, AS16..S
110.8 4.36"
10 0.39"
2x
M4 8-32 UNC
5.5 0.22"
35.4 1.39"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
35 1.38"
ø 4.2 0.17"
50 1.97"
45 1.77"
60 2.36"
72.5 2.85"
AS09..S, AS12..S, AS16..S
+ CA3..S front-mounted 1-pole auxiliary contact block
110.8 4.36"
10 0.39"
35.4 1.39"
35 mm EN/IEC 60715
68 2.68"
5.5 0.22"
35 1.38"
ø 4.2 0.17"
50 1.97"
2x
M4 8-32 UNC
7 0.28"
60 2.36"
72.5 2.85"
45 1.77"
AS09...16-30-32S
80 3.15"
ø 4.2 0.17"
AS09..S, AS12..S, AS16..S
+ VM3 mechanical interlock unit including two BB3 fixing clips
18 | ABB
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
1SBC101414S0201
50 1.97"
35 mm EN/IEC 60715
68 2.68"
5.5 0.22"
4x
M4 8-32 UNC
60 2.36"
72.5 2.85"
7 0.28"
10 0.39"
90 3.54"
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Main dimensions
mm, inches
72.5 2.85"
45 1.77"
2x
M4 8-32 UNC
10 0.39"
5.5 0.22"
35 1.38"
ø 4.2 0.17"
60 2.36"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
ASL09..S, ASL12..S, ASL16..S
110.8 4.36"
10 0.39"
72.5 2.85"
2x
M4 8-32 UNC
5.5 0.22"
35.4 1.39"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
35 1.38"
ø 4.2 0.17"
60 2.36"
45 1.77"
ASL09..S, ASL12..S, ASL16..S
+ CA3..S front-mounted 1-pole auxiliary contact block
110.8 4.36"
72.5 2.85"
10 0.39"
2x
M4 8-32 UNC
5.5 0.22"
35.4 1.39"
35 mm EN/IEC 60715
68 2.68"
7 0.28"
35 1.38"
ø 4.2 0.17"
60 2.36"
45 1.77"
ASL09...16-30-32S
72.5 2.85"
4x
M4 8-32 UNC
5.5 0.22"
80 3.15"
ø 4.2 0.17"
1SBC101414S0201
35 mm EN/IEC 60715
68 2.68"
10 0.39"
60 2.36"
7 0.28"
90 3.54"
ASL09..S, ASL12..S, ASL16..S
+ VM3 mechanical interlock unit including two BB3 fixing clips
ABB | 19
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising