Stop Cause # Message Description 1 Internal

Stop Cause # Message Description 1 Internal
Last Stop Cause - Robomow RL1000
Every time the mower stops with an error message ( + Press GO), it is possible to look at the 'Last stop cause' information under the 'Information' menu and
to have more details about the reason, which cause the mower to stop.
The table below shows the description of the stop cause:
Stop Cause
#
Message
Description
1
2
Internal issue
Blocked path
Bumper event was received during GO sequence
3
Start elsewhere
Software problem - bumper related
4
Start elsewhere
Software problem - bumper related
5
Start elsewhere
Software problem - bumper related
6
Start elsewhere
Software problem - bumper related
7
Drive overload
Drive motor overload
8
Low battery
Very low battery voltage
9
Start elsewhere
Software problem - wire related
10
Drive problem
Problem in the odometer (drive wheels are active but odometer pulses are not detected)
11
Drive overload
11 (Only in
2005
version) Start elsewhere
Drive motor overload
Time out during forward or backward movements during scanning (The robot is probably stuck)
12
Front wheel problem
Robomow has exceeded the allowed front wheel detection time (drop-off)
13
D.K. Problem
DK problem
14
Start elsewhere
DK current calibration failure (During the mowing motors activation in the GO sequence)
15
Start elsewhere
Software problem
16
Start elsewhere
Software problem - wire related
17
Start elsewhere
Software problem
18
Start elsewhere
Software problem
19
Start elsewhere
Time out during forward or backward movements during scanning (The robot is probably stuck)
20
No wire signale
Mechanism for recovering from electricity power interruption during automatic operation has failed
21
Mowing overload
Mechanism for recovering from electricity power interruption during automatic operation has failed
22
Front wheel problem
Robomow has exceeded the allowed front wheel detection time (drop-off)
23
Start elsewhere
Problem with the wire during Edge Robomow has detected that all 4 wire sensors are outside the garden for too long
24
Start elsewhere
25
Start elsewhere
Problem with the wire during Edge
Problem with the wire during Edge
Robomow unable to locate the wire for too long
26
Start elsewhere
Failure of the Wire Acquisition process
27
Start elsewhere
Software problem
28
Start elsewhere
Failure of the Wire Acquisition process rear bumper was detected during Acquisition
29
Max dist reached
Robomow has reached the maximal Edge distance during the "Learn Edge" process
30
Docking problem
Edge process was terminated before we reached the docking station
31
Start elsewhere
Software problem
32
Start elsewhere
Software problem
33
Drive overload
34
Check mow height
Mechanism for recovering from drive motors overheat during automatic operation has failed
Mowing motors problem
Mowing motors are off but high currents are measured. This means that either the mowing motors or the main board
are damaged.
35
Start elsewhere
36
Check mow height
Robot is stuck in place for too long during Edge operation
Mowing motors problem
High Mowing motors currents are detected after Mowing currents calibration in GO (after mowing motors are activated
for a few seconds when robot is not moving) .
37
Start elsewhere
Software problem
38
Start elsewhere
Software problem
39
Start elsewhere
Software problem
40
Check mow height
Mowing motors problem
Too many overcurrent events occurred during automatic mode.
41
Start elsewhere
Software problem
42
Start elsewhere
43
Check mow height
Software problem
Mowing motors problem
Overcurrent event during manual mode
44
Start elsewhere
Software problem
45
Docking problem
Failure connecting to the docking station
46
Start elsewhere
Software problem
47
Start elsewhere
Software problem
48
Start elsewhere
Software problem
49
Start elsewhere
Problem with the wire sensors readings
50
Start elsewhere
Software problem
51
Start elsewhere
Problem with the wire sensors readings
52
Start elsewhere
Software problem
53
Blocked path
Path is blocked
54
No wire signal during automatic operation
56
No wire signale
Front bumper
disconnected
Rear bumper
disconnected
57
Front bumper pressed Front bumper pressed
58
Front bumper pressed Front bumper pressed
59
Rear bumper pressed Rear bumper pressed
60
Move from wire
Problem with the wire sensors readings Perimeter wire might be too close
61
Start elsewhere
62
Start elsewhere
Problem with the wire sensors readings
Problem with the wire sensors readings
Wire synchronization failure
63
No wire signale
No wire signal
64
Set country
Set country
65
Calibration required
DK calibration is required
66
Enable dock
Enable/Disable docking station
67
Start elsewhere
Software problem
68
Blocked path
Bumper detection during manual mowing
69
No wire signale
No wire signal is detected in one of the wire sensors
70
Start elsewhere
Problem with the wire sensors readings
72
Start elsewhere
Software problem
73
Start elsewhere
Software problem
74
No message
Power suppiy over heat detected during the charging process
55
Front bumper disconnected
Rear bumper disconnected
71
75
77
Front bumper
disconnected
Rear bumper
disconnected
78
Time completed
Working time expired
79
Start elsewhere
Software problem
80
Start elsewhere
Software problem
81
Start elsewhere
Problem with the wire sensors readings
82
No wire signale
No wire signal
83
No wire signale
No wire signal detected during GO
84
Move from wire
Problem with the wire sensors readings Perimeter wire might be too close
85
Start elsewhere
Problem with the wire sensors readings
86
Start elsewhere
Problem with the wire sensors readings
87
No wire signale
No wire signal
76
Front bumper disconnected
Rear bumper disconnected
88
Move from wire
Problem with the wire sensors readings
89
Start elsewhere
Problem with the wire sensors readings
90
Move from wire
Problem with the wire sensors readings Perimeter wire might be too close
91
Start elsewhere
Problem with the wire sensors readings
92
Move from wire
Problem with the wire sensors readings Perimeter wire might be too close
93
Start elsewhere
Problem with the wire sensors readings
94
No wire signale
No wire signal
95
No wire signale
No wire signal
96
Recharge battery
Battery needs recharging
98
Start elsewhere
Software problem
100
Check mow height
Mowing motors problem
101
Mowing overload
Mowing motors overload
102
Drive overload
Drive motors overload
103
Start elsewhere
Problem with the wire sensors readings during Edge
Start elsewhere
Failure of the Wire Rescue maneuver
Start elsewhere
Software problem
113
Replace lamp
Replace lamp
114
Thermistors fail
Thermistors failure
115
Bumper disconnected Bumper disconnected
116
Bumper disconnected Bumper disconnected
117
Button name' pressed One of the remote's buttons is pressed during power up
118
Start elsewhere
99
104
105
106
107
108
109
110
111
112
Problem with the wire sensors readings
119
Rain detected
Rain detected
120
Replace plades
Replace blades
121
Docking problem
Robot did not succeed disconnecting from the docking
122
Docking problem
Edge process was terminated before we reached the docking station because perimeter island was detected
123
Docking problem
Edge process was terminated before we reached the docking station because we reached the required OK quarters
124
Docking problem
125
Docking problem
Software problem
Edge process was terminated before we reached the docking station because we reached the required edge distance that
was set by the user in this Zone
126
Docking problem
Edge process was terminated before we reached the docking station because we reached the required DK quarters
127
128
Max distance reached Robomow has reached the maximal Edge distance during the "Wire position test"
129
Test result: 'result'
Termination of the Edge termination test
130
Test result: 'result'
Termination of the docking station entry test
131
Docking problem
Robomow has slid off the docking station more than 5 times during the current charging process
132
Docking problem
Robomow has slid off the docking station more than 5 times during the current charging process
Low temperature
Ambient temperature is too high for more than 12 hours during the charging process
133
134
135
High temperature
Ambient temperature is too high for more than 12 hours during the charging process
136
Charging failure
Charging problem
137
Charging failure
Charging FET temperature is too high for more than 3 hours during the charging process
Check Perimeter
switch
Perimeter switch problem
139
Check power
No wire or charger voltage are detected in the docking station for more than 1 minute
140
Check power
Charging problem
138
141
STOP button was pressed during automatic operation
142
Remote was taken out during automatic operation
143
Left/Mid/Right mow
problem
Disconnected or burnt Left Right or Middle mowing motor
144
Start elsewhere
Robot stuck monitor detection. Robot is stuck in place for too long.
145
One of the following:
No wire signal
Mowing overload
Drive overload
Auto restart mechanism failure