BEAM Alliance central vacuum Operation Manual
Below you will find brief information for central vacuum Alliance. The Alliance central vacuum system is equipped with a flow-thru motor and will never need lubrication. Should you experience any problems with your motor, please contact your local authorized dealer/distributor. To ensure proper cleaning, use only one inlet at a time. If service is ever required, have it performed by your authorized Beam dealer.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
BEAM Alliance
Operation Manual
2
IMPORTANT SAFEGUARDS
When using an electronic appliance, basic safety precautions should always be followed, including those listed below.
READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM SYSTEM.
WARNING
To reduce the risk of fi re, electric shock or injury:
• This vacuum cleaner is intended for dry pick up only. Do not use on wet surfaces or pick up any liquids, hot debris or any fl ammable items that would cause harm to the vacuum cleaner.
• Keep cord away from heated surfaces.
• Do not allow vacuum to be used as a toy. Close supervision is necessary when this vacuum is used by or near children.
• Use this vacuum only for its intended use as described in this manual. (Use of attachments not recommended by manufacturer may cause fi re, electric shock, injury or damage to system
• components.)
• Connect to a properly grounded (earthed) outlet only. See grounding (earthing) instructions.
• Mount unit at least 30 cm (12 inches) from the fl oor, ceiling and corner sidewall to insure adequate ventilation for motor.
• Never operate this vacuum if it has a damaged cord or plug, if it is not working properly, or if it has been dropped or damaged. Return to authorized dealer/distributor for repair.
• Never disconnect plug by pulling cord. To disconnect from outlet, grasp the plug, not the cord.
• Do not put any object into openings. Do not use with any opening blocked. Keep free of dust, lint, hair and anything that may reduce air fl ow/suction. Lack of air fl ow will cause the motor to overheat.
• This vacuum cleaner creates suction. Keep hair, face, fi ngers, all body parts and loose clothing away from any openings.
• Never operate without dust bag and/or fi lter in place.
• Turn off all controls before unplugging.
• Never handle plug, cord or power unit with wet hands.
• Use extra care when cleaning on stairs.
• Do not locate the power unit in a high temperature area or where it is inaccessible, for example, an attic or crawl space.
• Do not use extension cords or outlets with inadequate current carry capacity.
• Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.
• Do not use on wet surfaces.
• Do not vacuum drywall dust or baking fl our as it may cause damage to your vacuum.
• This appliance is not intended for use by persons, (including children), with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• If the power cord is damaged, it must be replaced by a special cord available from the authorized local dealer/distributor.
• Keep your work area well lit.
• Unplug electrical appliances before vacuuming them.
• Do not pick up fl ammable or combustible liquids such as gasoline, or use in areas where they may be present.
SAVE THESE INSTRUCTIONS
Dear Beam Customer;
Congratulations on your new Beam Alliance Central Vacuum! You have just purchased Beam’s most innovative and intuitive Central Vacuum. Thank you for your support. For maximum benefi t, please read this instruction manual before installing and operating your central vacuum. You will want to keep these instructions for future reference.
To purchase or inquire about accessories and installation services, please contact your local dealer or visit our website at www.beam.com.
We recommend you register your Central Vacuum at our website www.beam.com.
For your convenience, write down the model number and serial number and model number located on your power unit below. You will fi nd these numbers on the rating plate located on the back top of the unit.
Model Number _______________________
Serial Number _______________________
Purchase Date _______________________
Opening the Package
Your Central Vacuum and its accompanying hardware and accessories are carefully packed in a cardboard package designed to protect it from transportation damage. You will fi nd the pieces needed to hook up your central vacuum packaged in the dirt bucket.
Installation of your Central Vacuum
If you are planning to install your central vacuum yourself, there is an excellent installation manual and installation video available to you online at www.beam.com. If you want a professional to install your central vacuum, please contact your local dealer or call 1-800-369-2326 in the United States and 1-800-282-2886 in
Canada. We will be happy to direct you to the professional installer in your area.
GENERAL INFORMATION
The central vacuum system is designed for dry pick up of household dirt and dust and is not intended to pick up liquids. Avoid picking up hard or sharp objects with the system to prevent hose and plastic pipe damage or clogs. This central vacuum system is intended for household use only.
Service Information
The instructions in this booklet serve as a guide to routine maintenance. For additional information, contact your local authorized dealer/distributor.
Rating Plate
The style, model and serial numbers are indicated on the rating plate located on back left side of power unit. For prompt and complete service information, always refer to these numbers when inquiring about service (refer to
Figure 1.) Figure 1.
3
GROUNDING INSTRUCTIONS
This vacuum must be grounded (earthed). If it should malfunction or breakdown, grounding (earthing) provides a path of least resistance for electric current to reduce the risk of electric shock. This vacuum is equipped with a cord having an equipment-grounding conductor and grounding (earthing) plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded (earthed) in accordance with all local codes and ordinances.
110/115/120V Models
This vacuum is for use on a nominal 110/115/120 volt circuit, and has a grounded plug like the one shown below. Make sure the appliance is connected to an outlet having the same confi guration as the plug. No adaptor should be used with this vacuum.
4
Grounded Pin Receptacle
Grounding Pin
Grounded Outlet
WARNING
Improper connections of the equipment-grounding (earthing) conductor can result in risk of electric shock.
Check with qualifi ed electrician or service person if you are in doubt as to whether the outlet is properly grounded (earthed). Do not modify the plug provided with the appliance. If it will not fi t the outlet, have the proper outlet installed by a qualifi ed electrician. This appliance is for use on a nominal 120 volt (see rating plate for correct voltage) circuit and has a ground (earth) plug that looks like the plug illustrated Make sure the appliance is connected to an outlet having the same confi guration as the plug.
• No adapter should be used with this appliance.
• Do not use an extension cord with this appliance.
• If the power cable is damaged, use only OEM replacement cable.
• Check the power unit on/off button and all inlet valves for operation.
• This power unit is intended for household and commercial use only.
INSTALLATION
Installation of Power Unit
The power unit hangs on the mounting bracket which is screwed to the wall. The bottom screws of the mounting bracket should be about 48” (122 cm) up from the fl oor to allow convenient removal of the dirt bucket. For proper motor cooling, there must be at least 12” (31 cm) between unit and the ceiling. If mounting on plaster or panel walls, be sure mounting screws enter studs. If mounting on concrete wall, drill the wall with a masonry bit and insert the appropriate wall anchors. Strip the low-voltage wires that were installed with the main trunk line. (Figure 2)
With optional “Quick Clean” Inlet on the power unit, connect trunk line wires to wire harness on back of unit before connecting to the spring loaded connectors on the back side of the power unit. If you do not have the “Quick Clean” valve option, simply connect the trunk line wires directly to the spring loaded connectors on the back side of the power unit. Connect the main tube line to the tube intake on the power unit with the connector and clamp provided.
Do not glue the connection to the power unit in case you wish to remove at a future date. This unit may be vented outside. Do not exceed a run of over 20 feet off of exhaust,
Do not vent power unit into a wall, ceiling or concealed space of a building.
Figure 2
NOTE: Power Unit On/Off button is used when unit is not equipped with “Quick Clean” inlet or as an over ride switch in the event your trunk line wiring becomes damaged. All other inlets operate automatically when hose end is inserted into inlet valve. The power cable has a three-prong female connector on one end. This connector must be plugged into the mating connector on the power unit. Plug the other end of the power cable into the wall electrical outlet.
WIRING: Check local codes, but use not less than #12-2 wires with ground. Plug power unit cord into appropriate electrical outlet. Be sure line voltage is sufficient to handle 20 amp loads.
Intake Flange
Your power unit has been designed for either a left or right pipe intake.
This is to give you more fl exibility when choosing the location you wish to hang your power unit. To change the direction of the intake fl ange, you simply remove the two
Torx 20 screws located on the intake fl ange and turn the intake fl ange 180 degrees. Secure the intake fl ange with the same two
Torx 20 screws. (Figure 3)
Figure 3
5
6
Muffler Installation
The muffler is installed to the exhaust located at the rear of the power unit using the 3 fi ttings provided and Torx 20 screws provided. We suggest you install your muffler as shown, prior to hanging your Power Unit (Although some modifi cation to this is acceptable), (Figure 4).
NOTE: Do not install muffler on the same side as the intake fl ange so as to not interfere with pipe intake. Insert the 90 degree fi tting into the muffler and screw into place.
Glue the next two fi ttings in place before connecting to the power unit. Use the Torx 20 screws provided to connect muffler to Power Unit.
NOTE: Do not glue the muffler pipe to the central vacuum unit.
Figure 4
HEPA Filter Installation (optional)
Use the Torx 20 screws to secure the 90 degree elbow provided to the HEPA fi lter. Use screws to connect HEPA fi lter to Power Unit. We recommend you install the HEPA fi lter before hanging your Power Unit. (Figure 5a)
NOTE: Do not glue the HEPA fi lter to the central vacuum unit.
NOTE: One elbow must be installed if the muffler or the HEPA fi lter is not used. (Figure 5b)
Figure 5b Figure 5a
BASIC OPERATION FOR BEAM ALLIANCE POWER UNIT
To operate, simply plug the hose into one of the handy wall inlet valves. The metal ring on the hose cuff will complete a low-voltage electrical circuit, which in turn activates a relay and turns on the system’s power unit. To turn off the power unit, simply unplug the hose from the inlet.
Note: When unplugging the hose, it is recommended to hold the inlet door open for a few seconds until the suction pressure has sufficiently decreased.
For safety purposes, a low-voltage circuit is utilized at the wall inlet. The power unit functions on a standard
110/120-volt circuit. There are optional hoses available with an on/off switch located on the handle.
Note: When using one of these optional hoses, it is important to properly align the hose with the wall inlet when plugging it in to prevent damage to the unit.
BASIC OPERATION FOR BEAM ALLIANCE HOSE
The BEAM Alliance hose is designed to work as an integrated system with the BEAM Alliance Power Unit. It will not work with any other Central Vacuum System. The BEAM Alliance Hose System brings more options to your fi ngertips!
Power Button
Variable Speed
Controls
ON/OFF
Brush Roll
Low
Variable Speed
Indicator
High
System Light:
Blue pulsating light
= system ready/stand-by
Red fl ashing light
= check power unit
Power Button
The Power button located on Alliance hose handle allows you to conveniently turn the Power Unit off and on at the handle. For those 110V/24V hoses needed to power an electric powerhead, you will fi nd a powerhead icon button conveniently located on the handle that allows you to turn the powerhead off and on.
Variable Speed Control
The BEAM Alliance Hose Handle is equipped with variable speed control allowing you to decrease or increase the speed of the motor and in effect the end of hose suction. You now can defi ne how much suction you need to do the specifi c job at hand! Decrease suction by pressing the (-) button, and increase suction press the (+) button. When the system is turned on the suction defaults to highest and so all Variable Speed Indicator bars will be lit. Decreasing suction decreases the number of indicator bars lit.
System Indicator
When the Alliance hose is connected to an inlet valve the fan blade image on hose handle will pulsate with a glowing blue light. This confi rms communication between the hose handle and power unit. When the fan blades are solid blue, all systems are GO. When the fan blades are RED, you should empty your bucket or check for other performance issue. If the fan blades begin FLASHING and are RED, you should turn off your vacuum immediately. Check over your power unit and if you are unable to diagnose issue, call your local dealer for service.
CARE AND MAINTENANCE
Your Beam Built-in Vacuum comes with a lifetime limited warranty (see complete warranty details in this pamphlet). It will give you a lifetime of trouble-free service by following some simple guidelines.
7
8
The BEAM Alliance central vacuum system is equipped with a fl ow-thru motor and will never need lubrication.
Should you experience any problems with your motor, please contact your local authorized dealer/distributor.
• Power unit can be dusted off with a clean, soft cloth. Caution: do not use liquid cleaners or water as an electrical shock may occur.
• Do not tamper with power unit. Do not place anything on top of power unit as this could restrict cooling air to the motor, causing the motor to overheat.
• Do not attempt to pick up anything that will not go through the cleaning tool or hose end. Do not use the system to pick up construction debris.
• Do not attach anything else to the system’s electrical power source. Be sure that a properly- sized protected circuit is used for your unit’s electrical requirements. Consult your authorized Beam dealer for the correct size.
• After removing the hose from the inlet, hold the inlet door open for a few seconds to help clear dirt from the vacuum tubing and make sure the power unit has been turned off.
• To ensure proper cleaning, use only one inlet at a time.
• If service is ever required, have it performed by your authorized Beam dealer.
Dirt Bucket Cleaning and Maintenance
All of the dirt vacuumed from your home is captured in the dirt bucket located on the bottom of your power unit.
It is important that you remember to empty it on a regular basis to ensure optimal performance. The frequency required is dependent on many factors in your home (i.e. type of fl oor coverings, number of people living in the home and how many pets). A general rule is to empty the dirt receptacle twice a year… in spring and in fall. It is ideal to empty the dirt bucket when it is half full.
To remove the bucket simply press the Release Ring in any two opposing positions and pull down. Empty the debris into a garbage can or bag and reinstall the bucket.
You will hear a click when it is properly reinstalled. It is important to note that the system will not operate properly if the bucket is not installed properly (Figure 6).
While the dirt receptacle is off, check that the cloth fi lter is free from debris, tears or puncture holes. A clean fi lter, free from holes gives your motor maximum protection and ensures optimal performance.
Figure 6
HEPA Filter Maintenance
It is recommended that you change the HEPA fi lter annually, (more regularly if you vacuum more than twice a week).
1. Open HEPA fi lter door with button located on the side, center of door.
2. Press down on the tab at top of fi lter and pull outwards,
(discard fi lter).
3. Insert New HEPA fi lter aligning and leading with the two plastic tabs at bottom of cavity.
4. Snap upright into place.
5. Close HEPA door without force. If the door does not close easily, remove and reinstall fi lter (Figure 7).
Figure 7
Hose Care
For optimum benefi t, the hose should be used and stored at temperatures above 40˚F (5˚C). Always hang up the hose when not in use using the hose hanger supplied. If hose should become clogged, insert the wand end into the utility inlet on the power unit. Seal connection. Turn on the power unit with the manual switch. The obstruction should be quickly vacuumed out. If, however, the hose remains clogged, insert an electrician’s fi sh tape (wire) or garden hose through the hose to remove the obstruction, being careful not to puncture the hose.
Disconnect hose handle from wands before storing. DO NOT store hose in direct sunlight.
TROUBLE-SHOOTING
Automatic Shut-Off
The Alliance Central Vacuum comes equipped with a timed automatic shut off set to automatically turn your power unit off if your vacuum is left to run for 30 minutes. The shut off is to protect you in the event the vacuum is inadvertently left on. The shut-off timer is easily reset by turning the power unit on by way of the on/off button on your hose handle or on the power unit.
The system is also equipped with a thermal protection shut-off to protect the power unit from overheating, In the event a thermal shut-off occurs, a motor fault icon will be displayed on the screen of the power unit and a red fl ashing fan blade will show on the Alliance hose handle. Please allow for the unit to cool for approximately 30 minutes. If the unit does not restart after the 30 minutes, please contact your local authorized dealer/distributor.
Partial Loss of Suction
1. Clean out dirt receptacle. Ensure fi lter is free from debris, tears and or punctures. If this does not resolves issue, see step 2.
2. Turn ON vacuum at Power Unit. Check suction at Power Unit. If strong, check the suction at each inlet. If it is not the same suction at each one, the line may be partially clogged. To locate a clog, compare the suction at each inlet. First check the inlet closest to the power unit then continue to check each successive inlet until you locate inlet with loss of suction.. The obstruction will be located between this inlet and the one previously checked. To remove clog, carefully insert electrician’s fi sh tape into the inlet and push obstruction through. Or,
If you have a secondary vacuum, you can put vacuum hose into inlet, turn on secondary vacuum and draw out obstruction. If this fails to remove the clog, call your local authorized dealer/distributor.
Total Loss of Suction (with motor running)
1. Check power, light on screen.
2. If you have good suction at the unit, but no suction in the hose then there is a clog in the pipes or hose. To remove the clog, refer to step 2 above or call your local authorized dealer/distributor. If obstruction is in your hose, take your hose to local dealer.
Motor Refuses to Start
1. Check to ensure central vacuum is plugged into an electrical outlet.
2. Check fuses or breakers in your homes electrical panel
3. If power unit has power but your inlets turn on vacuum, the problem will be in your low voltage wiring to the wall inlets.
4. If you are unable to resolve your issue, call your local authorized dealer/distributor.
9
10
SERVICE INFORMATION
The instructions in this booklet serve as a guide for routine operation and maintenance. For further
Information contact your local authorized dealer/distributor
BEAM ALLIANCE LED/LCD ICON CHART
SYMBOL DESCRIPTION
ON/OFF Button
AVAILABILITY
Standard
MEANING
Turns power unit on or off
ACTION REQUIRED
None g or
Navigation Buttons
Clock
Communication Link
Screen Saver
Variable Speed Indicator
Empty Bucket Indicator
Performance Bars
Flashing Performance Bars Alert
Motor Fault Indicators
Error Codes
On select models
On select models
On select models
On select models
On select models
On select models
On select models
On select models
Standard
On select models
These buttons are located below the display screen. Use to modify time or reset empty bucket indicator
A digital clock is located on the top left corner of the display screen of the power unit
Scroll through using Left ( < ) or
Right ( > ) buttons to appropriate icon. When the appropriate selection is highlighted, hold the
Enter ( ) button down for 5 seconds
You can choose from either a 12 or 24 hour clock. To set time, use the (<) and (>) buttons to arrive at the correct time. Press Enter ( ) when your selections are complete
The communication link icon appears at the top of the power when the hose connection into the inlet valve is complete and the hose handle is communicating with the power unit
When the power unit wakes from sleep mode, the screen saver icon will appear for 2-3 seconds before disappearing and other icons will appear
None
None
When the power unit is on, the fan blades on the screen will spin relative to the speed/suction indicated on the hose handle
None
The empty bucket indicator is timed to remind you to empty your dirt bucket. The power unit will communicate with the hose handle signalling fan blades to fl ash red
Empty dirt bucket and reset the system by pushing one of the two reset buttons and holding for 5 seconds or
3 - 4 bars indicate the system is performing at the optimum level.
Performance levels will change depending on the variable speed settings and during the use of specialty attachments
When 2 bars or less are illuminated, the airfl ow of your power unit is exceptionally restricted. The power unit will communicate to the hose handle and fl ashing red fan blades will display
Indicates a system fault or malfunction. This symbol may occur due to one of the following:
1) Maximum system run time exceeded; 2) Electronics problem;
3) Power surges; 4) Motor failure; 5)
Mechanical failure
Error codes defi ned:
ER 1: Under current
ER 2: Over current short
ER 3: 30-minute time out
ER 4: Over current long
ER 5: Line error or off current
Check for blockage if performance bars fl uctuate under normal vacuuming conditions
Check to ensure the dirt bucket is not overloaded. Check for blockages in the system. Check for motor wear (contact an authorized service technician)
Turn on and off the power unit. This may reset the system. If this fails, unplug the power unit and call an authorized technician
Turn off and unplug power unit and call an authorized technician.
For further detail on error codes, contact your authorized service dealer
WARRANTY
Lifetime Limited Warranty
Beam warrants to the original consumer purchaser that the Beam built-in vacuum power unit body and fi lter shall be free from defects in material and workmanship from the date of purchase until the original consumer purchaser ceases to own the system or until the system is removed from its original installation, whichever occurs fi rst. Motors and electrical components in Beam Alliance power units are warranted for 15 years.
Should any defect in material or workmanship appear within the time of the above warranty, the selling BEAM
Dealer should be contacted. The Dealer shall repair or replace (at BEAM’S sole option) or credit, such part or parts in accordance with the applicable warranty period stated above. BEAM shall not be responsible for such service unless provided by an authorized BEAM Dealer utilizing authentic BEAM replacement parts.
This warranty does not apply to loss or damage resulting from (at BEAM’s sole option) normal wear and tear, commercial use, neglect, abuse, acts of God, accidents, improper installation, improper modifi cation or alteration, improper use and operation or failure to provide proper maintenance.
Some States or Provinces do not allow exclusion of warranties or limitations of damages, so the above limitations and exclusions may not apply to you. This warranty gives you specifi c legal rights. You may have additional rights, which vary from State to State, or Province to Province. This limited warranty applies to USA and Canada installations only. For specifi c warranty information for your Country, consult your authorized Beam
Dealer.
Other warranties apply to other parts of this equipment and optional accessories. Please consult the materials accompanying the individual items.
BEAM SHALL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL, INCIDENTAL OR SPECIAL
DAMAGES ARISING FROM THE USE OF THIS SYSTEM.
Keep all payment records (bill of sale/delivery slip). The date on these records establishes the warranty period.
Should warranty service be required, you must show proof of purchase.
To place on fi le proof of the required information, fi ll out and return the Warranty Card, which is included in with your power unit, or register online at www.beamvac.com.
Note: Be sure to specify Model and Serial numbers when writing for information or replacement parts.
United States
10200 David Taylor Drive
Charlotte, NC 28262
1-800-369-2326
Canada
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-282-2886
www.beam.com
11
Sold and serviced by:
12
© 2013 Electrolux Home Care Products Ltd. #87238-R1
advertisement
Key Features
- Flow-thru motor
- Automatic shut-off
- Variable speed control
- HEPA filter
- Dirt bucket
- Hose hanger
- Lifetime warranty