INSTALLER AND OWNER GUIDE
5118776/08
Tiger
Model 944 Manual & 944RC Remote Control
CAST-IRON GAS STOVE
Fitted with a Ceramic Coal or Log fuel effect.
(GC No. 32-264-20)
For further advice please contact the retailer or company from where you purchased your fire
INSTALLER: Please leave this guide with the owner
©
GDC Group Ltd. 2015
INSTALLER GUIDE
THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20).
WHEN CONVERTED USING CONVERSION KIT NO. 0595261 THIS APPLIANCE
IS FOR USE WITH PROPANE GAS (G31) (944 MANUAL ONLY).
THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED
KINGDOM (GB) AND THE REPUBLIC OF IRELAND (IE).
© GDC Group Ltd.
All rights reserved. No part of this publication may be reproduced in any material form
(including photocopying), stored in any medium by electronic means (including in any retrieval system or database) or transmitted, in any form or by any means, whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner.
Applications for the copyright owner's permission to reproduce any part of this publication should be made, giving details of the proposed use, to the following address: The Marketing Communications Manager, GDC Group Ltd, Millbrook House,
Grange Dive, Hedge End, Southampton, SO30 2DF.
Warning: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages.
Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication
©
GDC Group Ltd. 2015
Page 2
INSTALLER GUIDE
INSTALLER GUIDE
FOR OWNER GUIDE SEE PAGES 22 TO 36
©
GDC Group Ltd. 2015
Page 3
INSTALLER GUIDE
LIST OF CONTENTS
Section Heading
INSTALLER GUIDE
OWNER GUIDE
1. SAFETY
2. APPLIANCE DATA AND EFFICIENCY
2.1 General information.
2.2 Efficiency.
3. GENERAL INSTALLATION REQUIREMENTS
3.1 Regulations, standards and law
3.2 The Hearth.
3.3 Clearances.
3.4 Flue / Chimney.
3.5 Ventilation.
3.6 Location.
3.7 Propane gas (944 Manual Only)
4. UNPACKING
5. STOVE SET UP
5.1 Legs and front cover
5.2 Deflector, diverter box and flue restrictor plate
5.3 Thermal switch
6. BURNER AND SUPPLY LINE INSTALLATION
6.1 Burner Installation
6.2 Gas Connection
7. FITTING THE CERAMIC FUEL EFFECT
8. OPERATING THE STOVE
8.1 Operation of the MANUAL CONTROL BURNER
8.1.1 Pre-lighting checks.
8.1.2 Lighting the burner.
8.1.3 Operating the burner.
8.2 Operation of the REMOTE CONTROL (RC) BURNER
8.2.1 Fitting battiers to the remote contrl handset
8.2.2 Fitting batteries to the receiver box
8.2.3 Setting the handset and receiver relationship
8.2.4 Lighting the stove
8.2.5 Adjusting the flame height
8.2.6 Adjusting to pilot only setting
8.2.7 Turning off
8.2.8 Inlet pressure check.
©
GDC Group Ltd. 2015
Page 4
Page
3 - 21
22 - 36
16
16
17
17
16
16
17
17
15
15
13
13
14
11
12
12
12
10
7
8
6
7
9
9
8
8
INSTALLER GUIDE
9. SPILLAGE AND FLAME SUPERVISION CHECKS
9.1 Check for spillage.
9.2 Flame supervision and spillage monitoring system.
10. FINAL REVIEW
11. SERVICING
18
20
21
©
GDC Group Ltd. 2015
Page 5
INSTALLER GUIDE
1. SAFETY
This product uses fuel effect pieces containing Refractory Ceramic Fibres
(RCF), which are man-made vitreous silicate fibres. Excessive exposure to these materials may cause irritation to eyes, skin and respiratory tract.
Consequently, it is important to take care when handling these articles to ensure that the release of dust is kept to a minimum. To ensure that the release of fibres from these RCF articles is kept to a minimum, during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the stove before and after working on the stove. When replacing these articles we recommend that the replaced items are not broken up, but are sealed within a heavy duty polythene bag, clearly labelled as RCF waste. RCF waste is classed as a stable, non-reactive hazardous waste and may be disposed at a landfill licensed to accept such waste. Protective clothing is not required when handling these articles, but we recommend you follow the normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking. This appliance does not contain any component manufactured from asbestos or asbestos related products.
Installer
Tiger stoves are efficient appliances giving off convected, conducted and radiated heat. All the surfaces of the stove, except the controls, are working surfaces and become hot in use. They must not be touched or have any combustible objects or materials placed on or near them. A fire guard complying with BS 8423 should be fitted for the protection of young children, the elderly, the infirm or pet animals.
The appliance is fitted with a flue safety device. If the appliance closes down after a period of operation for no apparent reason, the consumer should be informed to stop using the appliance until the installation and appliance have been thoroughly checked. Under no circumstances should the flue safety device be altered or bypassed in any way. Only a genuine manufacturers replacement part should be fitted.
Before continuing any further with the installation of this appliance please read the following guide to manual handling:
-
The approximate lifting weight of this appliance is
70 kg.
We therefore recommend that two people should be sufficient to lift the stove. If fitting or moving the stove alone we recommend the use of suitable lifting apparatus.
-
When lifting always keep your back straight. Bend your legs and not your back.
-
Avoid twisting at the waist. It is better to reposition your feet.
-
Avoid upper body/top heavy bending. Do not lean forward or sideways whilst
©
GDC Group Ltd. 2015
Page 6
INSTALLER GUIDE handling the stove.
-
Always grip with the palm of the hand. Do not use the tips of fingers for support.
-
Always keep the stove as close to the body as possible. This will minimise the cantilever action.
-
Use gloves to provide additional grip.
-
Always use assistance if required.
2. APPLIANCE DATA AND EFFICIENCY
2.1 General information.
Gas Natural (G20) Propane (G31) *
Inlet Pressure 20mbar
Manual Input - Max. (Gross) 6.85kW (23,372 Btu/h)
Manual Input - Min. (Gross) 2.3kW (7,850 Btu/h)
RC Input - Max. (Gross)
RC Input - Min. (Gross)
6.85kW (23,372 Btu/h)
3.5kW (11,943 Btu/h)
37mbar
6.7kW (22,860 Btu/h)
4.0kW (13,650 Btu/h)
N/A
N/A
Inlet Test Pressure (Cold)
20.0 ± 1.0mbar
(8.0 ± 0.4in w.g.)
37.0 ± 1.0mbar
(14.85 ± 0.4in w.g.)
Gas Connection
Burner Injector
Pilot
8mm pipe
Cat 82 - 072
Copreci Ref. O.D.S
21500/212
8mm pipe
Size 130
Copreci Ref. O.D.S
21500/212 Fitted with RBM
180 -02 injector
Integral piezo (Mounted on gas valve)
Manual Ignition
Remote Control Ignition
Integral piezo (Mounted on gas valve)
MERTIK GV60 battery powered electronic remote control
See page 21
Conversion not permitted on RC models
Aeration Non-adjustable
*When converting Manual using LPG kit
0595261.
Note:
- Converting from Natural gas (G20) to Propane (G31) is permitted ONLY on 944
MANUAL model together with the Coal ceramic set.
- If you have the 944 Manual with Log set conversion is NOT permitted.
- LPG conversion is also NOT permitted on the 944RC model (COAL or LOG).
The appliance data label is located on a plate at the base of the stove.
©
GDC Group Ltd. 2015
Page 7
INSTALLER GUIDE
2.2 Efficiency.
The efficiency of this appliance has been measured as specified in BS EN 613 and the result is as below :
Model
944 / 944 RC
944 when converted to LPG (Manual only)
Efficiency % (Gross)
69
71
The gross calorific value of the fuel has been used for this efficiency calculation. The test data from which it has been calculated has been certified by BSI.
The efficiency value may be used in the UK Government's Standard Assessment
Procedure (SAP) for energy rating of dwellings.
The conversion of net efficiency to gross was achieved by multiplying the net efficiency by the following conversion factor from Table E3 of SAP 2005, rounding down to the nearest whole number.
Gas
Natural Gas
LPG
Conversion factor from net to gross efficiency
0.901
0.921
3. GENERAL INSTALLATION REQUIREMENTS
3.1 Regulations, Standards and Law.
The installation must be in accordance with these instructions.
For the user’s protection, in the United Kingdom it is the law that all gas appliances are installed by competent persons in accordance with the current edition of the Gas
Safety (Installation and Use) Regulations. Failure to install the appliance correctly could lead to prosecution. GAS SAFE REGISTER require their members to work to recognised standards.
In the United Kingdom the installation must also be in accordance with all the relevant parts of local regulations.
BS 5440 Part 1
BS 5440 Part 2
BS 4543 Part 2
BS 5871 Part 1
BS 6891
BS 8303
In England and Wales, the current edition of the Building Regulations issued by the
Department of the Environment and the Welsh Office.
In Scotland, the current edition of the Building Standards (Scotland) Regulations
©
GDC Group Ltd. 2015
Page 8
INSTALLER GUIDE issued by the Scottish Executive.
In Northern Ireland, the current edition of the Building regulations (Northern Ireland) issued by the Department of the Environment for Northern Ireland.
In the republic of Ireland the installation must be carried out by a competent person and also conform to the relevant parts of: a) The current edition of IS 813 “Domestic Gas Installations” b) All relevant national and local rules in force.
Where no specific instructions are given, reference should be made to the relevant
British Standard Code of Practice.
3.2 The Hearth.
The appliance must be mounted on a non-combustible hearth (N.B. conglomerate marble hearths are considered as non-combustible). The hearth material must be at least 12mm thick. The hearth must protrude at least 150mm (6”) in front of the stove body. In most buildings with solid concrete floors this requirement will be met by the floor itself.
3.3 Clearances.
Clearances from combustible and non- combustible materials must be at least those shown in figure 1.
190mm
575mm
Figure 1. Dimensions and Clearances
395mm
365mm
IMPORTANT: Reducing the clearance distance at the rear of the stove (especially with non-combustible surfaces) can result in the stove switching off. This occurs when the thermal switch operates due to insufficient cool air.
©
GDC Group Ltd. 2015
Page 9
INSTALLER GUIDE
3.4 Flue / Chimney.
- diameter insulated Selkirk insta-lock gas vent.
- selkirk 5 SIL - DH draft hood connector. The inner sleeve will require reducing in length so that it protrudes 25mm below the outer sleeve (See figure
2).
- flue outlet is correctly positioned to align with the flue outlet on the stove and that the chimney is in good
Figure 2.
condition. If not, a chimney liner must be installed or a suitable class 2 gas flue used.
A draught is necessary to ensure the products of combustion are fully evacuated.
Connect and seal the stove flue collar to the chimney using full depth of collar. The flue must have a minimum effective height of 3 metres (10ft), however, to ensure optimum performance we recommend 3.66 metres (12ft) or higher. The flue must be free of obstruction and any dampers must be fixed in a permanently open position.
Ensure that the chimney is not closed and that it has been swept prior to the stove being installed. Make sure that rain, birds or any foreign bodies cannot get into the chimney and cause blockage or damage. This problem can normally be overcome by fitting an approved gas cowl. It is essential to the effective running of your stove that the chimney draws properly and allows the products of combustion to escape.
3.5 Ventilation.
- requirements of this appliance. In GB reference should be made to BS5871 Part 1 and in IE reference should be made to the current edition of IS 813 “ Domestic gas installations” which make clear the conditions that must be met to demonstrate that sufficient ventilation is available.
- area from which ventilation for the appliance is taken, if it does not affect the safe performance of the appliance. Note the spillage test requirements detailed further on in this manual. If the fan is likely to affect the appliance, the appliance must not be installed unless the fan is permanently disconnected.
3.6 Location.
This appliance must not be installed in a private garage or any room, which contains a bath, or shower or where steam is regularly present.
3.7 Propane gas (944 Manual Only).
Propane gas appliances must not be installed in a cellar, basement or other room which is built entirely below ground level (See Gas Safety (Installation and use)
Regulations)
©
GDC Group Ltd. 2015
Page 10
INSTALLER GUIDE
4. UNPACKING THE APPLIANCE
Before installation, check that the following components, where required, have been delivered.
MANUAL MODELS:
Loose parts box -
Accessory Pack -
Contains the down draught deflector, flue spigot, diverter box, four feet, lower front panel, restrictor plate and touch up paint.
+
Contains bolts, nuts, washers, wall plugs and screws.
Ceramic box -
Contains ceramic coal or log set. (Log set supplied separately from stove casting)
Stove Burner Assy box - Contains 944 burner module including rear burner support & knob assy . Item number 05944XX.
REMOTE CONTROL (RC) MODELS:
Loose parts box - Contains the down draught deflector, flue spigot, diverter box, four feet, lower front panel, restrictor plate
Accessory Pack -
and touch up paint.
+
Contains bolts, nuts, washers, wall plugs and screws.
Ceramic box -
Stove Burner (RC) -
Assy box
Contains ceramic coal or log set. (Log set supplied separately from stove casting)
Contains 944 RC burner module including rear burner support, remote control handset, PP3 Battery and 4 AA batteries. Item number 05944X4.
NOTE: The door is secured with a locking bolt and Hex nut. To open the door use a
3mm Allen key to loosen the hex nut on the side of the door, being carefull not to remove it completely. Ref to
Figure 3 below.
Then select a suitably sized spanner and turn counter clockwise by approximately a quarter turn on the handle to open.
Figure 3.
©
GDC Group Ltd. 2015
Page 11
INSTALLER GUIDE
5. STOVE SET UP
5.1 Legs and front cover (See figure 4).
1. Locate the four leg securing studs into the four holes in the base of the body.
2. Locate the four legs to the underside of the casting body. There are two feet with holes in the base. We recommend that these be placed at the rear of the stove.
Note: If lying the stove on its top it is advisable to remove the door before hand as it is not designed to stay in place when inverted.
3. Place the front cover plate on top of the front legs.
4. Secure the legs and front cover to the underside of the casting body using the nuts and washers supplied. The bolts should have the locking washer added first followed by the flat washer. The legs are
Figure 4.
fitted with height adjustment bolts that are to be used for levelling purposes only.
5.2 Deflector, diverter box and flue restrictor plate.
1. This appliance is supplied with a flue restrictor for use where the flue draught is excessive. There may however, be certain circumstances where fitting the restrictor causes the fire to fail the spillage test. In such cases the restrictor will have to be removed. After removal conduct the spillage test again.
2. The deflector, diverter box and flue restrictor plate should be assembled to the stove as in figure 5.
The deflector must be fitted first and is secured in place using the front bolt that secures the flue collar. Unscrew and remove the nut and washer from the front bolt and position the
Figure 5.
©
GDC Group Ltd. 2015
Page 12
INSTALLER GUIDE deflector as in figure 6, securing it using the nut and washer. It
MUST be sealed against the top of the stove casting. It is important that it sits on top and between the raised cast areas on the rear of the stove body (See figure 6). The flue spigot is screwed to the cast collar and clamps the flue restrictor plate in place (See figure
5).
5.3 Thermal switch.
The thermal switch should be fitted to the inside of the diverter box as in figure 7. Secure using the nut and bolt supplied. Never modify the fixing bracket and always ensure that the switch is fitted correctly. NEVER USE THE
STOVE IF THE THERMAL
SAFETY SWITCH HAS BEEN
REMOVED OR IF IT IS
DAMAGED IN ANY WAY.
Figure 6.
Figure 7.
6. BURNER AND SUPPLY LINE INSTALLATION
6.1 Burner installation.
1. Unpack the burner module.
2. Secure the control knob assembly to the gas valve, the screw tail should secure onto the flat on the gas valve spindle
(manual model only).
3. Secure the rear leg at the back of the stove base using two No.4
x 10mm screws supplied (See figure 8).
4. Offer the burner module into the stove and connect the
Figure 8.
thermal switch leads to the tags mid way along the thermocouple.
©
GDC Group Ltd. 2015
Page 13
INSTALLER GUIDE
5. Locate the burner assembly inside the stove body as in figure 9
(The outer body of the stove is not shown for clarity). Secure using the six No.4 x 10mm screws supplied
Figure 9.
6.2 Gas connection.
- bottom front of the appliance. The elbow can be rotated to allow a connection from any direction. The elbow includes a valve for isolating the gas supply.
-
Note: Prior to connecting the gas supply it is advisable to blow out the gas supply so that any dirt which may be present in the pipe is cleared and cannot enter the gas valve or pilot burner and so cause a blockage.
- Connect the supply line to the appliance.
- Turn on the gas supply and pressure check the installation pipework for gas soundness. In the United Kingdom (GB) check in accordance with the current edition of BS 6891. In the Republic of Ireland check in accordance with the current edition of
IS 813 “Domestic Gas Installations.”
7. FITTING THE CERAMIC FUEL EFFECT
The installer and owner guide for the ceramic fuel effect is supplied with the ceramic fuel effect. It is important that the installer guide for the ceramic fuel effect be placed inside or attached to this guide and handed to the customer following completion of the ‘Final review and servicing’ section.
©
GDC Group Ltd. 2015
Page 14
INSTALLER GUIDE
8. OPERATING THE STOVE
8.1 Operation of the MANUAL CONTROL burner.
8.1.1 Pre-lighting checks.
-
-
-
-
-
8.1.2 Lighting the burner.
1. If closed
, open the isolating valve at the inlet elbow.
2. Depress the control knob and rotate it
SLOWLY anticlockwise to the pilot ignition position. A 'click' will be heard as the integral piezo operates.
3. Turn the control knob clockwise to the 'Off' position. Repeat this operation until a flame appears at the pilot. The pilot can be seen by looking through the gap in the fuel effect (See figure 10a & 10b). There may be a delay before the pilot lights due to air being purged from the system. When a flame appears at the pilot keep the control knob depressed and hold the pilot ignition position for five seconds. When the control knob is released the pilot flame should remain lit.
Pilot Viewing
Figure 10a.
Pilot Viewing
Figure 10b.
8.1.3 Operating the burner.
When the pilot burner is operating properly, gradually turn the control knob anticlockwise to 'HIGH' (Depress the knob slightly to get past the pilot ignition position).
The main burner should now light. Depress the control knob slightly to release from the 'HIGH' position and turn back (clockwise) to 'LOW'. While turning, the burner flames should gradually become lower but remain alight. Depress the control knob slightly to release from the 'LOW' position and turn back (clockwise) to the ‘Pilot ignition’ position. The main burner should extinguish but the pilot should remain alight.
Depress the control knob slightly and turn back (clockwise) to turn OFF. This will extinguish the pilot.
©
GDC Group Ltd. 2015
Page 15
INSTALLER GUIDE
8.2 Operation of the REMOTE CONTROL (RC) burner.
8.2.1 Fitting batteries to the remote control handset.
The remote control handset is battery powered. There is a 9 Volt ‘PP3’ size battery supplied. Remove the rear battery compartment cover from the remote control
Handset handset. To do this push the tab towards the bottom of the handset and lift (See figure 11).
Fit the battery in to the handset. Replace the cover.
8.2.2 Fitting batteries to the receiver box.
The gas valve and receiver are battery powered. There are four 1.5 Volt ‘AA’ size batteries supplied. Remove the elastic band from around the bracket and receiver box.
Slide the receiver box forward and clear of the bracket holding it in place. Ensure that the
wires do not snag on the bracket when
removing the receiver box. Slide the battery
compartment cover clear (See figure 11) and fit the batteries. It is important that the +ve and -ve symbols on the battery match those of the illustration inside the battery holder.
Replace the cover and receiver box. It is
important that the wires from the receiver box do not touch the underside of the burner tray.
Receiver box
Figure 11. Battery compartment covers
8.2.3 Setting the handset and receiver relationship.
The receiver will have to be set to learn the handset / remote code. Do this as below:
Press and hold the reset button on the receiver (See figure 11) until you hear two (2) acoustic signals. After the second, longer acoustic signal, release the reset button.
Within the subsequent 20 seconds press the (small flame) button on the handset until you hear an additional long signal confirming the code is set (Please inform the customer that this is a one time setting as is NOT required when changing batteries in the handset or receiver).
©
GDC Group Ltd. 2015
Page 16
INSTALLER GUIDE
8.2.4 Lighting the stove.
If closed
, open the isolating ‘T’ connector valve.
Turn the ‘manual’ knob to the ON, full counterclockwise position.
Simultaneously press and hold the ‘OFF’ and
(large flame) buttons until a short acoustic signal confirms the start sequence has begun; release buttons. Continuing signals confirms the ignition is in progress. There will be a slight delay and several sparks should be see
n between the electrode and pilot tip. Once pilot ignition is confirmed there is main gas flow.
Main valve knob
Figure 12. Controls
MAN (Manual)
Knob for manual ignition
When pilot ignition is confirmed, the motor turns automatically to maximum flame height.
8.2.5 Adjusting flame height.
When the burner is operating press the (large flame) button to increase the flame height and press the (small flame) to decrease the flame height. For fine adjustment press the / button for approximately two seconds until an acoustic signal is given, then release the button.
8.2.6 Adjusting to pilot only setting.
When the burner is operating press and hold the (small flame) until the burner flame extinguishes. To turn the main burner on again simply press and hold the
(large flame) button.
8.2.7 Turning off.
To turn the fire off press the ‘OFF’ button.
©
GDC Group Ltd. 2015
Page 17
OWNER GUIDE
8.3 Inlet pressure check.
The appliance is pre-set to give the correct heat input at the inlet pressure shown in section 2 of this manual. No adjustment is necessary.
1. Ensure that the stove is turned OFF before removing the presure test point sealing screw. Check the inlet pressure by fitting a pressure gauge at the test point. The test point is on the inlet ‘T’ connector (See figure
13). Check the pressure with the appliance alight and set at maximum output.
Figure 13.
2. After checking, turn off the appliance. Remove the pressure gauge and replace the test point sealing screw.
3. Test around the sealing screw for gas soundness with a suitable leak detection fluid.
9. SPILLAGE AND FLAME SUPERVISION CHECKS
9.1 Check for spillage.
1. Close all doors and windows in the room containing the appliance.
2. Light the appliance and turn the control knob to the ‘HIGH’ position.
3. Leave the appliance on for five minutes.
4. A smoke match should be placed close to base of the diverter box. The installation is satisfactory if the smoke is drawn into the appliance/ flue way. Do not use a lighted match or a naked flame.
If the smoke is not drawn into the appliance leave the appliance alight at the maximum setting for a further
ten minutes
and then repeat the test. If the smoke is still not drawn into the appliance then disconnect the appliance and seek expert
advice.
5. If the above test is satisfactory open all internal connecting doors, hatches, etc. in the room. Keep all doors and windows that open to the outside of the building closed.
Recheck for spillage as above. If an extractor fan is installed in the same room as the appliance or a connecting room, check that spillage does not occur with the fan operating and all doors and other openings between the fan and the appliance open.
If the smoke is drawn into the appliance, continue with the installation. If the test is not satisfactory disconnect the appliance and advise the customer of the cause
of failure.
©
GDC Group Ltd. 2015
Page 18
OWNER GUIDE
9.2 Flame supervision and spillage monitoring system.
The pilot unit incorporates a system that will automatically shut off the gas supply if the pilot flame goes out. Check that the system operates properly as follows:
1. Light the appliance. Set at the “HIGH” position and leave for one minute.
2a. Manual Control models
Turn the control knob to the ‘OFF’ position. The pilot and main burner will go out.
2b. Remote Control (RC) models
Set to the low burning position. Isolate the gas supply at the inlet "T" connector. The pilot and main burner will go out.
Note the time when the pilot goes out. Listen for a snap sound at the gas tap. Note
the time when the sound is heard. This sound is caused by an electromagnetic valve shutting off the gas supply through the tap. The valve is located in the body of the tap. The valve should operate within 60 seconds of the pilot going out. If the valve does not operate within this time limit do not allow the appliance to be used until the fault has been corrected.
This monitoring system must not be adjusted, bypassed or put out of operation.
This monitoring system, or any of its parts, must only be exchanged using authorised parts.
Remote Control (RC) models.
3. Open the isolating valve on the inlet "T" connector. Screw in the end cap and test for leaks.
4. Turn the fire off.
©
GDC Group Ltd. 2015
Page 19
OWNER GUIDE
10. FINAL REVIEW
Final Review.
-
-
-
-
-
-
-
-
-
-
Point out that lighting instruction details are on the information label attached to the burner at the bottom of the appliance.
Explain to the customer that the appliance has a flame failure & spillage monitoring system. Point out the explanation of this system shown in the owner guide under
“Operating your stove”. Advise that if the stove goes out for any reason, wait at least ten minutes before relighting. Stress that if the monitoring system repeatedly shuts off the stove, the appliance should be switched off and a specialist should be consulted.
Advise the customer that they should read their owner guide before operating the stove and always follow the advice in the section headed “Cleaning your stove”.
Stress that no extra ceramic fuel effect pieces must be added over and above those supplied with the appliance and that any replacements must only be the authorised spares. Warn that ignoring this advice could cause incomplete clearance of the products of combustion with consequent health hazards.
Advise the customer that the appliance will operate to its maximum potential if the flue is primed during the first 20 – 30 minutes of use. To do this, simply turn the control knob to its highest setting. This will also burn off any carbon deposits that may have formed during previous use.
If using the appliance for long periods it is beneficial to change between settings. This will also help to remove any carbon deposits that may form during use.
Recommend that the appliance should be serviced by a competent person at least annually.
If the appliance is in premises in the United Kingdom occupied by a tenant, point out that by law a landlord must have any gas appliance, flue and pipework which is situated in a tenant’s premises checked for safety at least every 12 months.
Explain to the customer that when operating the stove for the first time, some vapours may be given off which may cause a slight odour and could possibly set off any smoke alarms in the immediate vicinity. These vapours are quite normal with new appliances. They are totally harmless and will disappear after approximately twelve hours use.
-
information label attached underneath the burner module at the bottom of the appliance.
©
GDC Group Ltd. 2015
Page 20
OWNER GUIDE
11. SERVICING
This product uses fuel effect pieces containing Refractory Ceramic Fibres
(RCF), which are man-made vitreous silicate fibres. Excessive exposure to these materials may cause irritation to eyes, skin and respiratory tract.
Consequently, it is important to take care when handling these articles to ensure that the release of dust is kept to a minimum. To ensure that the release of fibres from these RCF articles is kept to a minimum, during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the stove before and after working on the stove. When replacing these articles we recommend that the replaced items are not broken up, but are sealed within a heavy duty polythene bag, clearly labelled as RCF waste. RCF waste is classed as a stable, non-reactive hazardous waste and may be disposed at a landfill licensed to accept such waste. Protective clothing is not required when handling these articles, but we recommend you follow the normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking. This appliance does not contain any component manufactured from asbestos or asbestos related products.
- servicing.
-
- on page 9).
- which may cause imperfect flames or prevent a correct electrode spark.
- correctly as described in the installer and owner guide supplied with the ceramic fuel effect. The ceramic fuel effect guide may have been placed inside or attached to this guide.
Checking the aeration setting of the burner.
(For LPG models refer to the conversion guide - 944 Manual only).
- that the aeration setting is correct. Check the aeration shutter setting (See figure 14).
- screws, slide the aeration shutter to the position shown in figure 14 and tighten the fixing screws.
Figure 14. Aeration shutter setting
©
GDC Group Ltd. 2015
Page 21
OWNER GUIDE
OWNER GUIDE
©
GDC Group Ltd. 2015
Page 22
OWNER GUIDE
LIST OF CONTENTS
Heading Page
SAFETY
OPERATING YOUR STOVE
The Flame Sensing & Flue Blockage Safety System.
Operating the MANUAL CONTROL burner
To light the burner
Operating the burner.
Operating the REMOTE CONTROL burner
Operating the stove WITH a REMOTE CONTROL handset
Lighting the burner
Adjusting flame height
Adjusting to pilot only setting
Turning off
Operating the stove WITHOUT a REMOTE CONTROL handset 29
Lighting the burner in the event of battery failure 29
30
28
28
28
29
26
28
28
26
GAS CONSUMPTION
CLEANING YOUR STOVE
Cast Iron Surfaces
Opening the Door
The Glass Window
FITTING THE CERAMIC FUEL EFFECT
MAINTENANCE AND SERVICING
Battery life and replacement
Changing the batteries in the remote control receiver
Changing the batteries in the remote control handset
Regular maintenance.
Standard Waranty & Terms
31
31
31
31
30
30
30
30
31
32
33
This stove has been designed to meet the most stringent quality, performance and safety requirements to provide our customers with many years’ trouble-free service.
Your owner guide aims to improve your understanding and appreciation of your gas stove by providing simple and informative instructions to ensure that you benefit from the excellent performance and features it has to offer.
©
GDC Group Ltd. 2015
Page 23
OWNER GUIDE
SAFETY
-
-
-
-
-
-
IF YOU SMELL GAS
EXTINGUISH ALL NAKED FLAMES.
DON’T TURN ELECTRICAL SWITCHES ON OR OFF.
TURN OFF THE GAS SUPPLY AT THE METER OR TANK AS APPROPRIATE.
OPEN DOORS AND WINDOWS TO GET RID OF THE GAS.
IMMEDIATELY CALL THE GAS EMERGENCY SERVICE FROM A
NEIGHBOURS PHONE - SEE YOUR LOCAL TELEPHONE DIRECTORY.
Do have the gas stove installed by a competent person i.e. Gas Safe Registered
Installer (UK) or a Registered Gas Installer (Outside of UK). In the United Kingdom, installation must be in accordance with the latest edition of the Gas Safety
(installation & use) Regulations. In the Republic of Ireland, installation must be in accordance with all national and local regulations in force.
Do have the chimney swept prior to installation if it was previously used for solid fuel.
Do have the gas stove installed in accordance with the installation instructions. On no account must the stove stand on carpets or other combustible materials. The stove must stand on a non-combustible hearth surface. The hearth material must be at least
12mm (1/2”) thick and should protrude at least 150mm (6”) in front of the stove body.
Do provide the minimum clearances shown in figure 1.
190mm
575mm
Figure 1. Dimensions and Clearances
395mm
365mm
Do always use a fireguard complying with BS 8423 for the protection of young children, the elderly, the infirm or pet animals. The cast iron top, front, rear and sides
©
GDC Group Ltd. 2015
Page 24
OWNER GUIDE of this stove are considered to be working surfaces and so will become very hot when in use. Always take care when using this appliance.
Do wait three minutes before attempting to relight if the gas stove is switched off or the flames are extinguished for any reason (Your gas stove is fitted with a safety device that will automatically shut off the gas supply to the gas stove, if for any reason, the flame goes out. If this operates then wait at least ten minutes before operating the stove).
Do get advice about the suitability of any wall covering near your gas stove. Soft wall coverings (e.g. embossed vinyl, etc.) which have a raised pattern are easily affected by heat. They may, therefore, scorch or become discoloured when close to a heating appliance. Please bear this in mind whenever you are considering redecorating.
Do not use this stove with the door open or with the glass panel damaged or removed. The door should always be secured shut (See “Cleaning your stove”).
If the window is damaged or will not close securely the stove must be turned off and not used until the window is changed or corrected by a competent service engineer.
Do not hang clothing, towels or any other fabrics over the gas stove.
Do not put more loose ceramic coals on the gas stove than the number given in the guide supplied with the ceramic fuel effect. This may have been attached to or placed inside this guide. Never use any ceramic coals other than those authorised for this gas stove. Incorrect combustion and subsequent health hazard could result.
Do not put paper or other materials into your gas stove.
Do not use the gas stove with damaged base ceramics.
Do not place any combustible material (rugs, carpet, plastic tiles, etc.) on the hearth.
Do not attempt to clean or service the gas stove until it has been switched off and allowed to cool completely.
Do not leave the stove on if the house is left unoccupied for a long period. We recommend that the stove is turned fully off.
©
GDC Group Ltd. 2015
Page 25
OWNER GUIDE
OPERATING YOUR STOVE
PLEASE NOTE
When operating your stove for the first time, some vapours may be given off which may cause a slight odour and could possibly set off any smoke alarms in the immediate vicinity. These vapours are quite normal with new appliances. They are totally harmless and will disappear after approximately twelve hours use.
This stove is supplied with ceramic “coals” and “logs” to simulate a real coal/log stove. After some use, the coals/logs may change colour. This is quite normal.
The Flame Sensing & Flue Blockage Safety System.
For your safety, this appliance is fitted with a flue blockage safety device that will shut down the appliance in the event of abnormal flue conditions. This device is NOT a
substitute for an independently mounted Carbon Monoxide detector.
The device will also automatically shut off the gas supply to the gas stove if the pilot flame goes out for any reason. If the device starts to shut off the gas frequently,
get expert advice.
The system incorporates a probe that senses that the heat from the pilot flame is correct. If this probe is cool, the device will prevent any gas flow unless the control knob or remote button is kept depressed at the PILOT/IGN position.
If the safety system operates and the flames go out wait at least ten minutes before
attempting to relight.
Always make sure that the door is securely closed before lighting.
If the gas valve is operated to turn the stove off always wait at least three minutes
before attempting to relight.
Always make sure that the door is securely closed before lighting.
Operating the MANUAL CONTROL burner.
To light the burner
-
Depress the control knob and rotate it SLOWLY anticlockwise to the pilot ignition position (See figure 2). A 'click' will be heard as the integral piezo operates. A flame should appear at the pilot. The pilot can be seen by looking through the gap in the fuel effect (See figure 3). Keep the control knob depressed and hold the pilot ignition position for five seconds. When the control knob is released the pilot flame should remain lit. If a flame does not appear at the pilot then turn the control knob clockwise to the 'OFF' position and repeat the above.
Figure 2.
©
GDC Group Ltd. 2015
Page 26
OWNER GUIDE
Operating the burner.
-
When the pilot burner is operating properly, gradually turn the control knob anti-clockwise to
'HIGH' position. (Depress the knob slightly to get past the pilot ignition position). The main burner should now light.
Depress the control knob slightly to release from the 'HIGH' position and turn back (clockwise) to
'LOW'. While turning, the burner flames should gradually become lower but remain alight.
Depress the control knob slightly to release from the 'LOW' position and turn back (clockwise) to the Pilot ignition position. The main burner should extinguish but the pilot should remain alight. Depress the control knob slightly and turn back (clockwise) to turn OFF. This will extinguish the pilot.
While cooling, the ceramic fuel effects may
Pilot Viewing
Figure 3a.
Pilot Viewing
make some crackling noises. This is quite normal.
Figure 3b.
Note i) If the flames go out while setting the control, repeat the full lighting procedure. If the flames repeatedly go out have the stove serviced.
ii) Please note. When first turned on the flames will appear predominantly blue. The fuel effect pieces will take time to warm up. Although some glow will be seen after approximately ten minutes, the full visual effect will only be apparent after a somewhat longer time.
iii) The appliance will operate to its maximum potential if the flue is primed during the first 20 – 30 minutes of operation. To do this, simply slide the control button to its highest setting. This will also burn off any carbon deposits that may have formed during previous operations.
iv) If operating the appliance for long periods it is beneficial occasionally to change the settings. This will also help to remove any carbon deposits that may form during operation.
©
GDC Group Ltd. 2015
Page 27
OWNER GUIDE
Operating the REMOTE CONTROL (RC) BURNER.
Operating the stove WITH the Remote Control Handset.
Lighting the burner.
If closed
, open the isolating ‘T’ connector valve.
Turn the ‘manual’ knob to the ON, full counterclockwise position.
Simultaneously press and hold the ‘OFF’ and (large flame) buttons until a short acoustic signal confirms the start sequence has begun; release buttons. Continuing signals confirms the ignition is in progress. There will be a slight delay and several sparks should be see
n between the electrode and pilot tip. Once pilot ignition is confirmed there is main gas flow.
When pilot ignition is confirmed, the motor turns automatically to maximum flame height.
Adjusting flame height.
When the burner is operating press the (large flame) button to increase the flame height and press the (small flame) to decrease the flame height. For fine adjustment press the / button for approximately two seconds until an acoustic signal is given, then release the button.
Please note:
-
The flames on the N.G. appliance will appear predominantly blue. The flames on the L.P.G. appliance will appear predominantly yellow.
-
The appliance will operate to its maximum potential if the flue is primed during the first 20 – 30 minutes of operation. To do this, simply set the control knob to its ‘HIGH’ setting. This will also burn off any dust deposits that may have formed during the appliance being switched off.
Adjusting to pilot only setting.
When the burner is operating press and hold the (small flame) until the burner flame extinguishes. To turn the main burner on again simply press and hold the
(large flame) button.
©
GDC Group Ltd. 2015
Page 28
OWNER GUIDE
Turning off.
To turn the fire off press the ‘OFF’ button. After turning the fire off the remote control valve will return to its starting position. For this reason it is important to leave the appiance alone for a period of one (1) minute before attempting to relight.
Operating the stove WITHOUT the Remote Control Handset.
Lighting the burner in the event of battery failure.
1. Access the gas valve from the right hand side of the stove.
2. The ‘main valve knob’ is the knob on the left hand side (See figure 4). Turn this knob to the
‘OFF’, fully clockwise position .
3. The ‘manual knob’ is the knob on the right hand side (See figure 5). Turn this knob to the
‘OFF’, fully clockwise position.
4. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor. If you smell gas STOP! and follow the safety information below.
Main valve knob
Figure 4. Controls
-
DO NOT SMOKE.
-
EXTINGUISH ALL NAKED FLAMES.
-
DO NOT TURN ELECTRICAL SWITCHES ON OR OFF.
-
TURN OFF THE GAS SUPPLY AT THE METER OR TANK
AS APPROPRIATE.
-
OPEN DOORS AND WINDOWS TO GET RID OF THE
GAS.
-
IMMEDIATELY CALL THE GAS EMERGENCY SERVICE
FROM A NEIGHBOURS PHONE - SEE YOUR LOCAL
TELEPHONE DIRECTORY.
-
If you do not smell gas, proceed as below.
MAN (Manual)
Knob for manual ignition
6. With the ‘manual’ knob in ‘MAN’ position a manual pilot valve operator is accessible (See figures 5).
-
Fully push down the manual pilot valve operator
Figure 5. Pilot valve operator using the end of a pencil or similar and hold in, to start pilot gas flow. Immediately light the pilot with a match, while continuing to hold in the manual pilot valve operator for about ten (10) seconds after the pilot is lit. Release manual pilot valve operator. If pilot does not stay lit, repeat steps 2 through 7.
NOTE: If the pilot does not stay lit after several tries, turn the gas control knob
(main valve knob) to ‘OFF’ and proceed to step 10.
7. Turn the ‘manual’ knob to the ON, full counterclockwise position. The main burner will now light on the max flame setting.
©
GDC Group Ltd. 2015
Page 29
OWNER GUIDE
8. Turn main valve knob to the full ‘ON' counterclockwise position.
9. If the appliance will not operate, follow the instructions “To Turn Off” below and call the UK GDC Technical Helpline on 0844 879 35 88 or in the Republic of Ireland on 01
842 8222.
GAS CONSUMPTION
Model 944 MANUAL / 944 RC
Has a maximum natural gas input of 6.85kW (Gross)
Has a maximum natural gas output of 5.00kW
Has a minimum natural gas input of 2.3kW (Gross)
Has a minimum natural gas output of 1.67kW
Model 944 MANUAL when converted using LPG kit number 0595261
Has a maximum propane gas input of 6.7kW (Gross)
Has a maximum propane gas output of 5.03kW
Has a minimum propane gas input of 4.0kW (Gross)
Has a minimum propane gas output of 3.00kW
CLEANING YOUR STOVE
Turn the stove off and allow it to cool completely before attempting any cleaning. Note that it will retain heat for some time after it has been turned off.
Cast Iron Surfaces.
Regular dusting with a dry lint free cloth is all that should normally be necessary.
Opening the Door.
The door is secured with a locking bolt and Hex nut. To open the door use a 3mm
Allen key to loosen the hex nut on the side of the door, being carefull not to remove it completely. Ref to Figure A. Then select a suitably sized spanner and turn counter clockwise by approximately a quarter turn on the handle to open.
Always secure the door with the locking bolt and hex nut to prevent inadvertent opening and consequent injury or damage while the stove is in use.
To lock the door turn the locking bolt first clockwise followed by the hex nut until they reach there stoping points.
The Glass Window.
Any stains on the glass can be removed with a non-abrasive cleaner such as a ceramic hob cleaner. Never use abrasive cleaners. Clean the window carefully in accordance with the instructions supplied with the cleaner.
©
GDC Group Ltd. 2015
Page 30
OWNER GUIDE
FITTING THE CERAMIC FUEL EFFECT
The installer and owner guide for the ceramic fuel effect is separate from this guide.
The installer may have attached it to this guide or placed it inside. It is important that the installer and owner guide for the ceramic fuel effect is followed correctly. If replacing the ceramic fuel effect, where a new guide is supplied, follow the installer and owner guide supplied with the replacement fuel effect.
Keep the replacement installer and owner guide with this owner guide for future reference.
MAINTENANCE AND SERVICING
Battery Life & Replacement.
Please note: In order to ensure maximum battery life and optimal performance, we recommend that only 'Long Life' alkaline type replacement batteries are used.
Handset
Changing the batteries in the remote control receiver box.
Please note: In order to ensure maximum battery life and optimal performance, we recommend that only 'Long Life' alkaline type replacement batteries are used.
1. Remove the elastic band from around the
bracket and receiver box.
Receiver box
2. Slide the remote control receiver out of its
retention housing. Ensure that the wires do
not snag on the housing bracket when removing the receiver box.
3. Remove the receiver top cover (See figure
5)
4. Remove and discard the batteries from the
receiver.
Figure 6. Battery compartment covers
5. Fit four new ‘AA’ batteries as indicated inside the receiver base.
6. Replace the receiver top cover. Slide the receiver back into its housing.
Changing the battery in the remote control handset.
Please note: In order to ensure maximum battery life and optimal performance, we recommend that only 'Long Life' alkaline type replacement batteries are used.
1. Remove the rear cover from the handset.
2. Remove and discard the batteries from the handset.
3. Fit a new PP3 battery as indicated inside to in the remote control handset.
4. Replace the rear cover on the rear of the handset.
©
GDC Group Ltd. 2015
Page 31
OWNER GUIDE
Regular maintenance.
In order to achieve and maintain high levels of personal safety and performance efficiency, it is essential that the flue is kept clear of any form of obstruction.
In the United Kingdom it is the law that a landlord must have any gas appliance, flue and pipework which is situated in a tenant’s premises checked for safety at least every twelve months by a competent person (In the UK a GAS SAFE REGISTER engineer, Outside of the UK a REGISTERED GAS INSTALLER engineer).
We recommend that all gas appliances and their flues, wherever situated, are checked annually.
Servicing.
To help us quickly help you, please try to have the following information available before you contact us:
Type of stove (Gas).
Model/Name.
Serial Number.
You will also be asked for the fault, problem or request plus your Post Code.
-
If you wish to replace any of the ceramic fuel effect pieces, spare parts are available nationwide via the ‘interpart stockist network’. For your local stockist consult Yellow pages under Central Heating.
-
When fitting replacement parts it is important that only approved parts are used for maximum safety.
©
GDC Group Ltd. 2015